AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

1 1

2. AMENDMENT/MODIFICATION NO.

3. EFFECTIVE DATE

10/2/2018

4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

U.S. GENERAL SERVICES ADMINISTRATION

ACQUISITION MANAGEMENT DIVISION / FIELD SUPPORT

401 W WASHINGTON STREET, SUITE 210

PHOENIX, AZ 85003-2117

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

Interested Party

(X) 9A. AMENDMENT OF SOLICITATION

NO.

47PK0518R0015

9B. DATED (SEE ITEM 11)

09/17/2018

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, X is required to sign this document and return 1 copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

The purpose of this amendment is to add Exhibits and replace certain Plans and Specification sheets.

A. Insert and incorporate ADDENDUM No. 1 of Plans and Specifications with updated drawings AD101, AD111, A-121, and A-601.

B. Attach and incorporate Exhibits 2 and 3, (USDA Department Regulation 3902-001 and NRCS construction space sketch.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

16C. DATE SIGNED

NSN 7540-01-152-8070

Previous edition unusable

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 5

ADDENDUM NO. 1

TO: PLANS AND SPECIFICATIONS FOR USDA NRCS Phoenix AZ

USDA NRCS

Interior Space Reduction Phoenix Federal Building and Courthouse 230 N. 1st Avenue – 5th Floor Phoenix, AZ 85003

Bidders are hereby informed that the Construction Plans and/or Specifications are modified as follows:

Plan CHANGES:

1. AD101- Existing Suite entry door in the South West corner of the area of work was added to the demolition drawing.

2. AD111 – Demolition of existing acoustical ceiling at the South West suite entry in the common corridor was to the area of work on the Architectural Demolition Reflected Ceiling Plan.

3. A-121 – Keyed notes # 93 and #94 were added to further define the finish work required in the common area corridor where construction is occurring.

4. A-601 – Material Legend for Building Standard Finishes for Common Area Only was added to document.

ATTACHMENTS:

1. UPDATED DRAWINGS: AD101, AD111, A-121, A-601

OCTOBER 1, 2018

END ADDENDUM NO.1

21 3 4 5 6 7 8 9 10 11

F

E

A

B

C

D

D5 D5 D5 D5

D5

D10

USDA SWING SPACE

USDA TEMPORARY STORAGE

D2

D2

D2

D1

D4

SERVER

D11

D12

DEMOLITION PLAN GENERAL NOTES

1. DARK, DASHED LINES INDICATE EXISTING CONSTRUCTION WITH ASSOCIATED DOORS,

FRAMES, AND MILLWORK TO BE FULLY REMOVED. EXISTING FIRE ALARM NOTIFICATION

AND MONITORING DEVICES AT PARTITIONS TO BE REMOVED TO BE CAREFULLY SALVAGED

IN PLACE FOR REUSE AT FINAL PLAN. NEATLY COIL WIRES AND INDIVIDUALLY SUSPEND

FROM SLAB ABOVE FOR FUTURE RE-INSTALLATION. COORDINATE WITH ENGINEERING

DOCUMENTS.

2. SOLID, FILLED LINES INDICATE EXISTING PARTITION CONSTRUCTION TO REMAIN UNLESS

OTHERWISE NOTED. REMOVE EXISTING WALLCOVERING IF PRESENT. PATCH AND REPAIR

WALLS TO REMAIN AS REQUIRED FOR “LIKE NEW” CONDITION. PROTECT DURING ALL

PHASES.

3. FOR AREA OF TENANT SUITE RENOVATION, REMOVE ALL PARTITIONS, DOORS, FRAMES,

MILLWORK AND FINISHES FOR FULL EXTENT. FULLY REMOVE EXISTING CEILING

ASSEMBLIES, LIGHT FIXTURES AND ABOVE CEILING MEP BRANCH ELEMENTS AS REQUIRED

BY NEW WORK. SCOPE IS NOT FULLY ILLUSTRATED ON PLAN--COORDINATE WITH ON-SITE

EXISTING CONDITIONS FOR ACTUAL SCOPE. FINAL DEMOLITION TO LEAVE SITE "BROOM

CLEAN." PREPARE ALL REMAINING SURFACES SMOOTH AND READY TO RECEIVE NEW

FINISHES.

4. REMOVE EXISTING FLOORING FINISH MATERIALS AND ASSOCIATED WALL BASE FOR FULL

PROJECT SCOPE, UNLESS SPECIFICALLY NOTED OTHERWISE. SELECTIVELY REPAIR,

INCLUDING SKIM COATING AS NECESSARY, GWB PARTITIONS AND COLUMN SURROUNDS

SLATED TO REMAIN SMOOTH TO ELIMINATE EVIDENCE OF BASE REMOVAL PROCESS.

5. REMOVE EXISTING BASE CABINET AND WALL CABINET MILLWORK WITH ASSOCIATED

CLEATS AND ANCHORS. WHERE MILLWORK EXPOSES AN EXISTING PARTITION FACE TO

REMAIN, PATCH PARTITION SMOOTH TO PROVIDE “LEVEL 4” FINISH AND TO ELIMINATE

EVIDENCE OF FORMER MILLWORK ATTACHMENTS. PREPARE FOR NEW WALL BASE

INSTALLATION.

6. ANY GYPSUM BOARD COLUMN FURRING TO REMAIN UNLESS OTHERWISE NOTED.

7. "PASS THROUGH" BUILDING SYSTEMS (PIPING, CONDUIT, ETC.) SERVING OTHER FLOORS,

ARE TO REMAIN, UNLESS OTHERWISE NOTED. PARTITION AND FURRING CONSTRUCTION

LOCATED AT PASS THROUGH LOCATIONS TO REMAIN, UNLESS OTHERWISE NOTED.

8. WHERE ELECTRICAL RECEPTACLES, COMMUNICATION RECEPTACLES, CARD ACCESS

READERS, LIGHT FIXTURES, THERMOSTATS OR SIMILAR DEVICES ARE TO BE REMOVED IN

PARTITIONS TO REMAIN, PATCH SMOOTH EXISTING PARTITION TO ELIMINATE EVIDENCE OF

FORMER LOCATION.

9. DO NOT CUT OR REMOVE STRUCTURAL STEEL, STRUCTURAL CONCRETE, OR LOAD

BEARING UNIT MASONRY WITHOUT WRITTEN APPROVAL OF TENANT REPRESENTATIVE.

10. REMOVE ALL EXISTING ROOM IDENTIFICATION AND MISCELLANEOUS DIRECTORY OR

INFORMATIONAL SIGNAGE FROM PREVIOUS TENANT FIT-OUT. EXISTING LIFE SAFETY,

EVACUATION, ELEVATOR, AND CODE REQUIRED SIGNAGE TO REMAIN. WHERE SIGNAGE

REMOVAL EXPOSES AN UNFINISHED SURFACE TO REMAIN, PATCH SURFACE SMOOTH TO

RECEIVE NEW FINISHES. SURRENDER REMOVED SIGNAGE TO CLIENT FOR REUSE WHERE

POSSIBLE.

11. PREPARE FOR NEW FLUSH FLOOR CORES TO COORDINATE WITH NEW FREE-STANDING

MILLWORK OR FURNITURE. PROVIDE LOCALIZED CORE DRILLS FOR NEW POKE-THRUS OR

SAW CUTS AND REINFORCEMENT FOR RECESSED FLOOR BOX ASSEMBLIES. COORDINATE

WITH ENGINEERING DRAWINGS. REFERENCE FURNITURE PLAN.

12. WHERE DEMOLITION EXPOSES FLOOR SLAB OPENINGS, REPAIR TO MATCH EXISTING

CONSTRUCTION. CONFIRM/COORDINATE WITH STRUCTURAL DRAWINGS FOR OPENINGS

OVER 1' - 0".

13. PROTECT BASE BUILDING HVAC SYSTEM FROM DUST DURING ALL PHASES.

14. PROTECT EXISTING PARTITION, FLOOR, ELEVATOR, AND CEILING FINISHES BEYOND

CONTRACT AREA FROM DAMAGE DURING ALL PHASES.

15. PROTECT EXISTING SMOKE DETECTORS, EMERGENCY STROBES, EMERGENCY FIRE PULLS,

AND ALL OTHER CONTROL, MONITORING OR NOTIFICATION DEVICES DURING ALL PHASES.

COORDINATE WITH CONSTRUCTION DOCUMENTS AND BUILDING REPRESENTATIVE FOR

ADDITIONAL INFORMATION AND RESTRICTIONS.

16. EXISTING SPRINKLER SYSTEM TO REMAIN. REFERENCE FIRE PROTECTION DRAWINGS FOR

MODIFICATION SCOPE. PROTECT DURING ALL PHASES. COORDINATE WITH

CONSTRUCTION DOCUMENTS AND TENANT REPRESENTATIVE FOR SPRINKLER

RESTRICTIONS.

17. AT AREAS OF FLOOR FINISH REMOVAL, ADDITIONALLY PREPARE SLAB SMOOTH AND FLUSH

TO ACCOMMODATE INSTALLATION OF NEW SCHEDULED FINISH FLOOR MATERIALS.

PREPARATION TO INCLUDE SELECTIVE FLOOR GRINDING, BEAD BLASTING, AND FLASH

PATCHING AS REQUIRED TO YIELD A SMOOTH AND LEVEL SUB SURFACE.

18. AT FIRE EXTINGUISHERS TO BE REMOVED, SALVAGE INVENTORY, IF ANY, AND STORE FOR

REUSE AT FINAL PLAN. FULLY CLEAN, REPAIR AND RECHARGE EXTINGUISHER CANISTERS

PRIOR TO RE-INSTALLATION

19. PROTECT EXISTING WINDOW BLINDS DURING CONSTRUCTION. CLEAN AT END OF PROJECT.

ANY DAMAGE CREATED FROM REMOVAL/REINSTALLATION MUST BE REPAIRED.

20. ANY FURNITURE OR EQUIPMENT LEFT BEHIND IN DEMO AREA TO BE REMOVED AND

DISPOSED OF AS PART OF CONSTRUCTION CONTRACT.

21. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION

REQUIREMENTS.

22. REMOVE ALL EXISTING AV EQUIPMENT AND STORE IN USDA TEMPORARY STORAGE ROOM

551 FOR REINSTALLATION.

DEMOLITION PLAN KEYED NOTES DEMOLITION PLAN LEGEND

EXISTING PARTITION TO REMAIN

EXISTING DOOR TO REMAIN

EXISTING PARTITION / DEVICES TO BE DEMOLISHED

EXISTING DOOR TO BE DEMOLISHED

GIVE BACK SPACE

AREA NOT IN SCOPE

D

C

B

A

1 2 3 4 5

ISSUE FOR CONSTRUCTION (100%)

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Jacobs Project No.:

Scales:

P H

O E

N

IX

F E

D E

R A

L B

U

IL

D

IN

G A

N D

C O

U R

T H

O U

S E

N

S T

A V

E N

U E th F

L O

O R

P H

O E

N

IX

A

Z

U S

D A

N R

C S

IN

T E

R

IO

R S

P A

C E

R E

D U

C T

IO

N

F5Y65908

15 DEC 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

PROPERTY OF THE UNITED STATES

GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice.

Properly destroy documents when no longer needed.

B

IM

/U

S -F

Y

-U

S D

A N

R S

C /U

S -F

Y

-U S

D A

N R

S C

-A R

C H

-V .r v t

/1

/2

:0

:0

A

M

AD101MJB

LEV

MLW

ARCHITECTURAL

DEMOLITION

FLOOR PLAN

1/8" = 1'-0"A1

DEMOLITION FLOOR PLAN

D1 REMOVE EXISTING PLUMBING FIXTURE AND PIPING. CAP LINES AT SOURCE AS REQUIRED.

EXISTING VALVES TO REMAIN

D2 PROVIDE PHYSICAL BARRIER BEFORE NEW DEMISING WALL IS BUILT. PROTECT EXISTING

SPACE THAT IS NOT A PART OF GIVE BACK SPACE

D4 REMOVE EXISTING CASEWORK

D5 REMOVE SECTION OF EXISTING PARTITION CONSTRUCTION AT LOCATION OF NEW ENTRY

ALCOVE. COORDINATE WITH ARCHITECTURAL PLAN

D10 REMOVE EXISTING DOOR AND SIDELIGHT AND SALVAGE FOR REINSTALLATION AT IT

OFFICE

D11 REMOVE EXISTING DOOR AND SALVAGE CIPHER LOCK FOR REINSTALLATION

D12 REMOVE EXISTING DOOR AND ALCOVE

1/8" = 1'-0"

24'4' 8' 16'

N

1 ADDENDUM 1 10/01/18

E

A

B

C

D

D9D9

D9D9

D9D9

1D9

DEMOLITION PLAN LEGEND

EXISTING PARTITION TO REMAIN

EXISTING DOOR TO REMAIN

EXISTING PARTITION / DEVICES TO BE DEMOLISHED

EXISTING DOOR TO BE DEMOLISHED

GIVE BACK SPACE

AREA NOT IN SCOPE

DEMOLITION PLAN KEYED NOTESDEMOLITION PLAN GENERAL NOTES

1. DARK, DASHED LINES INDICATE EXISTING CONSTRUCTION WITH ASSOCIATED DOORS,

FRAMES, AND MILLWORK TO BE FULLY REMOVED. EXISTING FIRE ALARM NOTIFICATION

AND MONITORING DEVICES AT PARTITIONS TO BE REMOVED TO BE CAREFULLY SALVAGED

IN PLACE FOR REUSE AT FINAL PLAN. NEATLY COIL WIRES AND INDIVIDUALLY SUSPEND

FROM SLAB ABOVE FOR FUTURE RE-INSTALLATION. COORDINATE WITH ENGINEERING

DOCUMENTS.

2. SOLID, FILLED LINES INDICATE EXISTING PARTITION CONSTRUCTION TO REMAIN UNLESS

OTHERWISE NOTED. REMOVE EXISTING WALLCOVERING IF PRESENT. PATCH AND REPAIR

WALLS TO REMAIN AS REQUIRED FOR “LIKE NEW” CONDITION. PROTECT DURING ALL

PHASES.

3. FOR AREA OF TENANT SUITE RENOVATION, REMOVE ALL PARTITIONS, DOORS, FRAMES,

MILLWORK AND FINISHES FOR FULL EXTENT. FULLY REMOVE EXISTING CEILING

ASSEMBLIES, LIGHT FIXTURES AND ABOVE CEILING MEP BRANCH ELEMENTS AS REQUIRED

BY NEW WORK. SCOPE IS NOT FULLY ILLUSTRATED ON PLAN--COORDINATE WITH ON-SITE

EXISTING CONDITIONS FOR ACTUAL SCOPE. FINAL DEMOLITION TO LEAVE SITE "BROOM

CLEAN." PREPARE ALL REMAINING SURFACES SMOOTH AND READY TO RECEIVE NEW

FINISHES.

4. REMOVE EXISTING FLOORING FINISH MATERIALS AND ASSOCIATED WALL BASE FOR FULL

PROJECT SCOPE, UNLESS SPECIFICALLY NOTED OTHERWISE. SELECTIVELY REPAIR,

INCLUDING SKIM COATING AS NECESSARY, GWB PARTITIONS AND COLUMN SURROUNDS

SLATED TO REMAIN SMOOTH TO ELIMINATE EVIDENCE OF BASE REMOVAL PROCESS.

5. REMOVE EXISTING BASE CABINET AND WALL CABINET MILLWORK WITH ASSOCIATED

CLEATS AND ANCHORS. WHERE MILLWORK EXPOSES AN EXISTING PARTITION FACE TO

REMAIN, PATCH PARTITION SMOOTH TO PROVIDE “LEVEL 4” FINISH AND TO ELIMINATE

EVIDENCE OF FORMER MILLWORK ATTACHMENTS. PREPARE FOR NEW WALL BASE

INSTALLATION.

6. ANY GYPSUM BOARD COLUMN FURRING TO REMAIN UNLESS OTHERWISE NOTED.

7. "PASS THROUGH" BUILDING SYSTEMS (PIPING, CONDUIT, ETC.) SERVING OTHER FLOORS,

ARE TO REMAIN, UNLESS OTHERWISE NOTED. PARTITION AND FURRING CONSTRUCTION

LOCATED AT PASS THROUGH LOCATIONS TO REMAIN, UNLESS OTHERWISE NOTED.

8. WHERE ELECTRICAL RECEPTACLES, COMMUNICATION RECEPTACLES, CARD ACCESS

READERS, LIGHT FIXTURES, THERMOSTATS OR SIMILAR DEVICES ARE TO BE REMOVED IN

PARTITIONS TO REMAIN, PATCH SMOOTH EXISTING PARTITION TO ELIMINATE EVIDENCE OF

FORMER LOCATION.

9. DO NOT CUT OR REMOVE STRUCTURAL STEEL, STRUCTURAL CONCRETE, OR LOAD

BEARING UNIT MASONRY WITHOUT WRITTEN APPROVAL OF TENANT REPRESENTATIVE.

10. REMOVE ALL EXISTING ROOM IDENTIFICATION AND MISCELLANEOUS DIRECTORY OR

INFORMATIONAL SIGNAGE FROM PREVIOUS TENANT FIT-OUT. EXISTING LIFE SAFETY,

EVACUATION, ELEVATOR, AND CODE REQUIRED SIGNAGE TO REMAIN. WHERE SIGNAGE

REMOVAL EXPOSES AN UNFINISHED SURFACE TO REMAIN, PATCH SURFACE SMOOTH TO

RECEIVE NEW FINISHES. SURRENDER REMOVED SIGNAGE TO CLIENT FOR REUSE WHERE

POSSIBLE.

11. PREPARE FOR NEW FLUSH FLOOR CORES TO COORDINATE WITH NEW FREE-STANDING

MILLWORK OR FURNITURE. PROVIDE LOCALIZED CORE DRILLS FOR NEW POKE-THRUS OR

SAW CUTS AND REINFORCEMENT FOR RECESSED FLOOR BOX ASSEMBLIES. COORDINATE

WITH ENGINEERING DRAWINGS. REFERENCE FURNITURE PLAN.

12. WHERE DEMOLITION EXPOSES FLOOR SLAB OPENINGS, REPAIR TO MATCH EXISTING

CONSTRUCTION. CONFIRM/COORDINATE WITH STRUCTURAL DRAWINGS FOR OPENINGS

OVER 1' - 0".

13. PROTECT BASE BUILDING HVAC SYSTEM FROM DUST DURING ALL PHASES.

14. PROTECT EXISTING PARTITION, FLOOR, ELEVATOR, AND CEILING FINISHES BEYOND

CONTRACT AREA FROM DAMAGE DURING ALL PHASES.

15. PROTECT EXISTING SMOKE DETECTORS, EMERGENCY STROBES, EMERGENCY FIRE PULLS,

AND ALL OTHER CONTROL, MONITORING OR NOTIFICATION DEVICES DURING ALL PHASES.

COORDINATE WITH CONSTRUCTION DOCUMENTS AND BUILDING REPRESENTATIVE FOR

ADDITIONAL INFORMATION AND RESTRICTIONS.

16. EXISTING SPRINKLER SYSTEM TO REMAIN. REFERENCE FIRE PROTECTION DRAWINGS FOR

MODIFICATION SCOPE. PROTECT DURING ALL PHASES. COORDINATE WITH

CONSTRUCTION DOCUMENTS AND TENANT REPRESENTATIVE FOR SPRINKLER

RESTRICTIONS.

17. AT AREAS OF FLOOR FINISH REMOVAL, ADDITIONALLY PREPARE SLAB SMOOTH AND FLUSH

TO ACCOMMODATE INSTALLATION OF NEW SCHEDULED FINISH FLOOR MATERIALS.

PREPARATION TO INCLUDE SELECTIVE FLOOR GRINDING, BEAD BLASTING, AND FLASH

PATCHING AS REQUIRED TO YIELD A SMOOTH AND LEVEL SUB SURFACE.

18. AT FIRE EXTINGUISHERS TO BE REMOVED, SALVAGE INVENTORY, IF ANY, AND STORE FOR

REUSE AT FINAL PLAN. FULLY CLEAN, REPAIR AND RECHARGE EXTINGUISHER CANISTERS

PRIOR TO RE-INSTALLATION

19. PROTECT EXISTING WINDOW BLINDS DURING CONSTRUCTION. CLEAN AT END OF PROJECT.

ANY DAMAGE CREATED FROM REMOVAL/REINSTALLATION MUST BE REPAIRED.

20. ANY FURNITURE OR EQUIPMENT LEFT BEHIND IN DEMO AREA TO BE REMOVED AND

DISPOSED OF AS PART OF CONSTRUCTION CONTRACT.

21. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION

REQUIREMENTS.

22. REMOVE ALL EXISTING AV EQUIPMENT AND STORE IN USDA TEMPORARY STORAGE ROOM

551 FOR REINSTALLATION.

D

C

B

A

1 2 3 4 5

ISSUE FOR CONSTRUCTION (100%)

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Jacobs Project No.:

Scales:

P H

O E

N

IX

F E

D E

R A

L B

U

IL

D

IN

G A

N D

C O

U R

T H

O U

S E

N

S T

A V

E N

U E th F

L O

O R

P H

O E

N

IX

A

Z

U S

D A

N R

E

R

IO

R S

P A

C E

R E

D U

C T

IO

N

F5Y65908

15 DEC 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

PROPERTY OF THE UNITED STATES

GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice.

Properly destroy documents when no longer needed.

B

IM

/U

S -F

Y

-U

S D

A N

R S

C /U

S -F

Y

-U S

D A

N R

S C

-A R

C H

-V .r v t

/1

/2

:1

:3

A

M

AD111MJB

LEV

MLW

ARCHITECTURAL

DEMOLITION

REFLECTED CEILING PLAN

1/8" = 1'-0"

24'4' 8' 16'

N 1/8" = 1'-0"A1

DEMOLITION REFLECTED CEILING PLAN

D9 REMOVE EXISTING ACOUSTICAL PANEL CEILING AND GRID. REFERENCE MECHANICAL AND

ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION

IC

E

FINISH PLAN GENERAL NOTES

1. NOT ALL FINISHES ARE SHOWN, ONLY THOSE REQUIRED FOR CLARIFICATION. REFERENCE

ROOM FINISH SCHEDULE ON A-601 FOR COMPLETE FINISHES.

2. REFERENCE MATERIAL LEGEND ON A-601 FOR FINISH INFORMATION.

3. REFERENCE A4 / A-601 FOR CARPET TO LUXURY VINYL TILE TRANSITION DETAILS.

4. REFERENCE INTERIOR ELEVATIONS FOR WALL FINISH DETAILS.

5. ALL NEW SOFFITS TO BE PAINTED PT-2.

6. ALL COLUMNS TO BE PAINTED PT-2.

7. INSTALLED CARPET AND LVT SHALL BE PROTECTED WITH BROWN PAPER OR PLASTIC

SHEETING FOR DURATION OF CONSTRUCTION.

8. WALLCOVERING INSTALLATION TO BE FREE FROM BUCKLES, BLISTERS, WRINKLES, LOOSE

EDGES, OPEN SEAMS OR STAINS. CONTRACTOR TO USE NEW BLADE FOR EACH

WALLCOVERING CUT REQUIRED ONSITE.

9. MILLWORK SHALL BE INSTALLED WITH CONCEALED HANGING METHODS ONLY.

10. EXPOSED FINISH SURFACES (JAMBS, SOFFITS, COUNTERTOPS, MILLWORK, ETC.) SHALL BE

PROTECTED WITH DROP CLOTHS OR CARDBOARD ENCLOSURES FOR THE DURATION OF

CONSTRUCTION TO PREVENT DAMAGE AND WEAR.

11. SGF-1 AND SGF-2 SHALL BE INSTALLED FULL HEIGHT AND WIDTH OF GLASS INDICATED.

FINISH PLAN KEYED NOTES

21 3 4 5 6 7 8 9 10 11

F

E

A

B

C

D

VESTIBULE

OFFICE

OFFICE

OFFICE

OFFICE

10-PERSON CONFERENCE

DIRECTOR'S OFFICE

OPEN OFFICE

OFFICE

OFFICE

QUIET ROOM

IT OPEN OFFICE

LARGE CONFERENCE

LARGE CONFERENCE

BREAK ROOM

COPY / PLOT

OFFICE

HUDDLE

HOTELING

LIBRARY

OPEN OFFICE

CLOSET

SERVER

CPT-1LVT-1

LVT-1

ALIGN

CPT-1

SGF-1

SGF-1

SGF-2

4' - 0"

WC-1

WC-1

WC-1 WC-1

WC-1

IT OFFICE

IT WORKROOM

91 91

SGF-1

94 94 94

1 1

FINISH PLAN LEGEND

NEW PARTITION

NEW DEMOUNTABLE PARTITION

GIVE-BACK SPACE

AREA NOT IN SCOPE

D

C

B

A

1 2 3 4 5

ISSUE FOR CONSTRUCTION (100%)

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Jacobs Project No.:

Scales:

P H

O E

N

IX

F E

D E

R A

L B

U

IL

D

IN

G A

N D

C O

U R

T H

O U

S E

N

S T

A V

E N

U E th F

L O

O R

P H

O E

N

IX

A

Z

U S

D A

N R

E

R

IO

R S

P A

C E

R E

D U

C T

IO

N

F5Y65908

15 DEC 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

PROPERTY OF THE UNITED STATES

GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice.

Properly destroy documents when no longer needed.

B

IM

/U

S -F

Y

-U

S D

A N

R S

C /U

S -F

Y

-U S

D A

N R

S C

-A R

C H

-V .r v t

/1

/2

:3 :2

P

M

A-121MJB

LEV

MLW

ARCHITECTURAL

FINISH PLAN

1/8" = 1'-0"

24'4' 8' 16'

91 REFER TO ELEVATION C4/A-401 FOR TYPICAL APPLICATION OF FABRIC TACKABLE PANELS

AND DRY ERASE SURFACE ON OPERABLE PARTITION (BOTH SIDES).

92 INSTALL FWP-2 ABOVE BACKSPLASH.

93 REFER TO A-601 FOR BUILDING STANDARD FINISHES

94 PROVIDE FINISH ON BOTH SIDES OF CONSTRUCTION, WHERE WORK OUTSIDE TENANT

SPACE OCCURS REFER TO A-601 BUILDING STANDARD FINISHES TO MATCH EXISTING

1/8" = 1'-0"A1

FINISH PLAN

N

ROOM FINISH SCHEDULE GENERAL NOTES

1. REFER TO PLANS FOR PARTITION TYPES.

2. PROVIDE "V" SHAPED CONTROL JOINTS IN GYPSUM BOARD ASSEMBLIES AT 30'-0" OC

MAXIMUM OR AS NOTED. COORDINATE LOCATIONS WITH ARCHITECT PRIOR TO

CONSTRUCTION.

3. PROVIDE FIRESTOPPING AT PERIMETERS AND PENETRATIONS OF FIRE RATED GYPSUM

BOARD ASSEMBLIES.

4. PROVIDE TRANSITION STRIPS AT ALL CHANGES IN FLOOR FINISH MATERIALS. REFER TO

DRAWING A2/A-601.

5. PAINT ALL STEEL DOORS AND FRAMES PT-4.

6. PROVIDE WATER RESISTANT GYPSUM BOARD AT PARTITIONS WITH PLUMBING

FIXTURES UNLESS OTHERWISE NOTED.

7. ALL PIPING NOT CONCEALED IN PARTITIONS OR ABOVE CEILING SHALL BE PAINTED.

REFER TO SPECIFICATIONS.

ROOM FINISH SCHEDULE LEGEND

FLOORS

CPT CARPET TILE

ESD ELECTROSTATIC

DISCHARGE TILE

LVT LUXURY VINYL TILE

BASE

-- NONE

RB 4" RUBBER

WALLS / PARTITIONS

GLAZ GLAZING

GYP GYPSUM

DMP DEMOUNTABLE PARTITION

-- NONE

PT PAINT

GT GLASS WALL TILE

OP OPERABLE PANEL PARTITION

SGF SPECIALTY GLAZING FILM

WC WALLCOVERING

CEILINGS

APC 24" x 24" ACOUSTICAL PANEL

CEILING

GYP GYPSUM BOARD

PT PAINT

ROOM FINISH SCHEDULE REMARKS

1. PROVIDE 1/2" CEMENT BOARD UNDER ALL PARTITIONS WITH GLASS WALL TILE (GT-1).

2. AT ALL ROOMS DESIGNATED AS "IT", "TELECOMMUNICATION", OR "TELECOM",

PROVIDE 3/4", A/C GRADE OR BETTER, VOID-FREE, FIRE- RESISTANT PLYWOOD

KILN-DRIED TO MAX MOISTURE CONTENT OF 15 PERCENT, ON FACE OF ALL

PARTITIONS (COORDINATE WITH TELECOM REQUIREMENTS). EXTEND PLYWOOD

FROM FLOOR TO 8'-0" AFF. FASTEN PLYWOOD THROUGH GYPSUM BOARD TO STEEL

STUDS WITH 2" SCREWS AT 16" OC EACH WAY. PRIME AND PAINT PLYWOOD TO

MATCH PARTITION. GYPSUM BOARD CONCEALED BY PLYWOOD NEED NOT BE

PAINTED.

3. DO NOT INSTALL RUBBER BASE ON OPERABLE PARTITION.

4. PROVIDE LEVEL 5 WALL FINISH AT WALLS WHERE WC IS TO BE INSTALLED.

5. APPLY SGF-1 TO GLAZING, OPEN OFFICE SIDE OF PARTITION.

6. PT-2 APPLIED TO SOFFIT ONLY WHEN NOTED WITH DEMOUNTABLE PARTITION.

ROOM FINISH SCHEDULE

MATERIAL LEGEND

FLOORS

CARPET FLOORING

CPT-1 MANUFACTURER:

STYLE NAME:

STYLE NUMBER:

COLOR NAME:

INSTALL:

SIZE:

LVT-1 MANUFACTURER:

STYLE NAME:

COLOR NAME:

SIZE:

LOCATION:

STATIC CONTROL RESILIENT FLOORING

ESD-1 MANUFACTURER:

SERIES:

COLOR NAME:

COLOR NO:

SIZE:

WALLS/PARTITIONS

INTERIOR PAINT

PT-1 MANUFACTURER:

COLOR NO/NAME:

LOCATION:

FINISH:

PT-2 MANUFACTURER:

COLOR NO/NAME:

LOCATION:

FINISH:

PT-3 MANUFACTURER:

COLOR NO/NAME:

LOCATION:

FINISH:

MISCELLANEOUS

CASE WORK (INTERIOR ARCHITECTURAL WOODWORK)

PL-1 MANUFACTURER:

COLOR NAME:

COLOR NO:

FINISH:

LOCATION:

NOTE:

SOLID SURFACE (INTERIOR ARCHITECTURAL WOODWORK)

SSM-1 MANUFACTURER:

COLOR NAME:

COLOR NO:

LOCATION:

THICKNESS:

FABRIC WRAPPED PANELS

FWP-1 MANUFACTURER:

SERIES:

THICKNESS:

FABRIC:

FABRIC NAME:

FABRIC COLOR:

SIZE:

NOTE:

ACOUSTICAL PANEL CEILINGS

APC-1 MANUFACTURER:

STYLE:

SIZE:

COLOR:

GRID:

GRID SIZE:

GRID COLOR:

LUXURY VINYL TILE

WALL BASE

RUBBER BASE

RB-1 MANUFACTURER:

SERIES:

COLOR NAME:

COLOR NO:

HEIGHT:

OPERABLE PARTITION

MANUFACTURER:

STYLE:

TACKABLE FINISH:

MARKER FINISH:

SPECIALTY GLAZING FILM

MANUFACTURER:

SERIES:

STYLE:

LOCATION:

PRICING:

CPT-2 MANUFACTURER:

STYLE NAME:

STYLE NUMBER:

COLOR NAME:

INSTALL:

SIZE:

MILLIKEN

MORAINE - RELIEF

REF180-119

BORDER

MONOLITHIC

50CM x 50CM

RASKIN GORILLA FLOORS

STUDIO - ELEVATIONS

ELEV-105 BOWERY

12" x 24"

BREAK ROOM, COPY/PLOT ROOM

ARMSTRONG

STATIC DISSIPATIVE TILE

PEARL WHITE

51953 12" x 12" x 1/8" THICK

JOHNSONITE

COLORMATCH

BLACK

#40 4"

MILLIKEN

MORAINE - RELIEF

REF141-180-119

BORDER WITH GREEN

MONOLITHIC

50CM x 50CM

SHERWIN WILLIAMS

SW6252 ICE CUBE

GENERAL PAINT

EGGSHELL

SHERWIN WILLIAMS

SW6416 SASSY GREEN

COLUMNS AND SOFFITS

EGGSHELL

SHERWIN WILLIAMS

SW6664 MARIGOLD

BREAK ROOM

EGGSHELL

GLASS WALL TILE

GT-1 MANUFACTURER:

STYLE:

COLOR:

SIZE:

LOCATION:

GROUT:

GROUT JOINT:

AMERICAN OLEAN

COLOR APPEAL GLASS MOSAIC WALL TILE (MESH MOUNT)

PEARL C101

1" x 1" TILES (11-3/4" x 11-3/4" SHEET)

BREAK ROOM BACKSPLASH

LATICRETE "BRIGHT WHITE" #44, UNSANDED

1/8"

SGF-1

NEVAMAR

BOHEMIAN EDGE

WO1400-WE

WOOD ESSENCE

BREAK ROOM 533 AND COPY/PLOT 512

MILLWORK - VERTICAL SURFACES

PL-2 MANUFACTURER:

COLOR NAME:

COLOR NO:

FINISH:

LOCATION:

NOTE:

NEVAMAR

TRUE WHITE

S645-SM

SUPER MATTE

LIBRARY 522, COPY/PLOT 512

MILLWORK - COUNTERTOP AND OPEN SHELVES

LG HAUSYS

NORDIC WHITE

S214

BREAK ROOM 533 - COUNTERTOPS

1/2" THICK

NOTE: CPT-2 TO BE INSTALLED RANDOMLY WITHIN CPT-1 FIELD.

CPT-1 = 75%

CPT-2 = 25%

MODERNFOLD

ACOUSTI-SEAL 932

DESIGNTEX "GAMUT"

MAGNETIC DRY ERASE BOARD

FINISHES

ARMSTRONG

LYRA SQUARE TEGULAR

24" X 24"

WHITE

SUPRAFINE XL

9/16"

WHITE

GOLTERMAN & SABO

ATM ACOUSTI-TACK

5/8" OVERALL

DESIGNTEX

GAMUT

TBD

FULL LENGTH AND HEIGHT OF WALL. PANELS NOT

TO EXCEED 48"W.

REFER TO ELEVATIONS FOR LOCATIONS

FWP-2 MANUFACTURER:

SERIES:

THICKNESS:

FABRIC:

FABRIC NAME:

FABRIC COLOR:

SIZE:

NOTE:

GOLTERMAN & SABO

SOUND TRANSMISSION LOSS PANEL

2-1/8" OVERALL

DESIGNTEX

GAMUT

TBD

FULL LENGTH OF WALL, 42" HIGH PANELS. PANELS

NOT TO EXCEED 48"W. INSTALL ABOVE

BACKSPLASH.

QUIET ROOM 506

VINYL WALLCOVERING

MANUFACTURER:

SERIES:

STYLE:

LOCATION:

PRICING:

WC-1 DESIGNTEX

BESPOKE DW17 - CUSTOM PROJECT SI 17962

SATARA STEEL W/WHITE INK

REFER TO A-121

MONICA BELL 207.517.8444

MBELL@DESIGNTEX.COM

PT-4 MANUFACTURER:

COLOR NO/NAME:

LOCATION:

FINISH:

SHERWIN WILLIAMS

SWXXXX

DOOR FRAMES

SEMI-GLOSS

DESIGNTEX

GF07

CUSTOM PROJECT - SI 17962

REFER TO A-121

MONICA BELL 207.517.8444

MBELL@DESIGNTEX.COM

(FIELD 75%)

(ACCENT 25%)

TRANSITION

TS-1 MANUFACTURER:

STYLE:

COLOR:

SIZE:

LOCATION:

ARMSTRONG

LUXURY FLOORING CARPET TRANSITION STRIP

VTL60130 - BLACK

12' - 0" LENGTH

CPT TO LVT DEMOUNTABLE PARTITION FINISHES

MANUFACTURER:

FINISH (M6):

FINISH (M7):

NOTE:

DIRRT

PAINTED MDF - STANDARD "STARWHITE" DC18

MAGNETIC MARKER BOARD, WHITE

SEE ELEVATION A1 / A-601 FOR TYPICAL

APPLICATION ON EACH PANEL

DMP-1

MANUFACTURER:

FINISH (M6):

NOTE:

DIRRT

PAINTED MDF - STANDARD "STARWHITE" DC18

NON-SEGMENTED PANELS WITH M6 FINISH

APPLIED.

DMP-2

MANUFACTURER:

FINISH:

NOTE:

DIRRT

OWNER TO SELECT FROM MANUFACTURER'S

STANDARD ACOUSTIC TILE SELECTIONS.

NON-SEGMENTED PANELS

DMP-3

MANUFACTURER:

FINISH:

DIRRT

CLEAR TEMPERED GLASS

DMP-4

MANUFACTURER:

SERIES:

STYLE:

LOCATION:

PRICING:

SGF-2 DESIGNTEX

GF11

CUSTOM PROJECT - SI 17962

REFER TO A-121

MONICA BELL 207.517.8444

MBELL@DESIGNTEX.COM

TRANSITION STRIP (TS-1)

CARPET

LUXURY VINYL TILE

SLAB

M6

M6

M7

2'

6"

5'

8"

MATERIAL LEGEND - BUILDING STANDARD FINISHES FOR COMMON AREA ONLY

FLOORS

CARPET FLOORING

CARPET MANUFACTURER:

STYLE NAME:

STYLE NUMBER:

COLOR NAME:

INSTALL:

SIZE:

NOTE:

WALLS/PARTITIONS

INTERIOR PAINT

PAINT WALLS MANUFACTURER:

COLOR NO/NAME:

LOCATION:

FINISH:

PAINT DOOR FRAMES MANUFACTURER:

COLOR NO/NAME:

LOCATION:

FINISH:

ACOUSTICAL PANEL CEILINGS

APC MANUFACTURER:

STYLE:

SIZE:

COLOR:

GRID:

GRID SIZE:

GRID COLOR:

WALL BASE

RUBBER BASE MANUFACTURER:

SERIES:

COLOR NAME:

COLOR NO:

HEIGHT:

SHAW

PETO II 26 TILE

59371

SLATE 71525

MONOLITHIC

24" X 24"

SHAW DIFFUSE/DISPERSE STYLE IS ALTERNATE

JOHNSONITE

COLORMATCH

BLACK

#40 4"

DUNN EDWARDS SPARTAZERO

SAILCLOTH

COMMON AREA WALLS (CORRIDOR SIDE)

EGGSHELL

DUNN EDWARDS SPARTAZERO

SAILCLOTH

DOOR FRAMES

GLOSS

ARMSTRONG

DUNE #1775

24" X 24"

WHITE

SILHOUETTE XL

9/16"

WHITE

D

C

B

A

1 2 3 4 5

ISSUE FOR CONSTRUCTION (100%)

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Jacobs Project No.:

Scales:

P H

O E

N

IX

F E

D E

R A

L B

U

IL

D

IN

G A

N D

C O

U R

T H

O U

S E

N

S T

A V

E N

U E th F

L O

O R

P H

O E

N

IX

A

Z

U S

D A

N R

E

R

IO

R S

P A

C E

R E

D U

C T

IO

N

F5Y65908

15 DEC 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

PROPERTY OF THE UNITED STATES

GOVERNMENT FOR OFFICIAL USE ONLY

Do not remove this notice.

Properly destroy documents when no longer needed.

B

IM

/U

S -F

Y

-U

S D

A N

R S

C /U

S -F

Y

-U S

D A

N R

S C

-A R

C H

-V .r v t

/1

/2

:2 :5

P

M

A-601MJB

LEV

MLW

ARCHITECTURAL

ROOM FINISH

SCHEDULE

ROOM

NO. NAME

FLOORING BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING

CEILING

HIEGHT REMARKS

FLOORING

COLOR BASE COLOR FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR

SUBSTRATE

MATERIAL FINISH COLOR

500 VESTIBULE CPT RB-1 PT-1 PT-2 / DMP-4 PT-1 PT-1 APC APC-1 9'-1" 4, 5, 6

501 OFFICE CPT RB-1 DMP-1 PT-2 / DMP-4 PT-1 PT-1 APC APC-1 9'-1" 6

502 OFFICE CPT RB-1 DMP-1 PT-2 / DMP-4 DMP-2 PT-1 APC APC-1 9'-1" 6

503 OFFICE CPT RB-1 PT-1 PT-2 / DMP-4 DMP-1 PT-1 APC APC-1 9'-1" 6

504 OFFICE CPT RB-1 PT-1 DMP-1 PT-2 / DMP-4 PT-1 APC / GYP APC-1 / PT-1 9'-1" / 8'-6" 6

505 OFFICE CPT RB-1 PT-1 DMP-1 PT-2 / DMP-4 DMP-2 APC APC-1 9'-1" 6

506 QUIET ROOM CPT RB-1 PT-1 / FWP-2 PT-1 / PT-2 / GLAZ PT-2 / DMP-4 DMP-3 APC / GYP APC-1 / PT-1 9'-1" / 8'-6" 5, 6

507 10-PERSON CONFERENCE CPT RB-1 PT-2 / DMP-4 PT-1 / PT-2 / GLAZ PT-1 / FWP-1 PT-1 / DMP-1 APC / GYP APC-1 / PT-1 9'-1" / 8'-6" 5, 6

508 DIRECTOR'S OFFICE CPT RB-1 PT-2 / DMP-4 DMP-1 PT-1 PT-1 / DMP-2 APC APC-1 9'-1" 6

509 OFFICE CPT RB-1 PT-2 / DMP-4 PT-1 / DMP-2 PT-1 DMP-1 APC APC-1 9'-1" 6

510 HUDDLE CPT RB-1 PT-2 / DMP-4 DMP-1 PT-1 / FWP-1 DMP-1 APC APC-1 9'-1" 5.6

511 OFFICE CPT RB-1 PT-2 / DMP-4 DMP-1 PT-1 PT-1 APC APC-1 9'-1" 6

512 COPY / PLOT LVT RB-1 PT-1 PT-1 PT-1 PT-1 APC APC-1 9'-1"

520 HOTELING CPT RB-1 WC-1 / PT-2 -- PT-1 / PT-2 PT-1 / PT-2 APC APC-1 9'-1" 4

521 OPEN OFFICE CPT RB-1 WC-1 / PT-2 -- PT-1 / PT-2 -- APC APC-1 9'-1" 4

522 LIBRARY CPT RB-1 PT-1 PT-1 PT-1 PT-1 APC APC-1 9'-1"

523 OPEN OFFICE CPT RB-1 PT-1 / PT-2 PT-1 / PT-2 / GLAZ PT-2 WC-1 / PT-2 APC APC-1 9'-1" 4

530 LARGE CONFERENCE CPT RB-1 REF C4 / A-401 PT-1 PT-1 / FWP-1 PT-1 / PT-2 APC / GYP APC-1 / PT-1 9'-1" / 8'-6" 3

531 CLOSET CPT RB-1 PT-1 PT-1 PT-1 PT-1 APC APC-1 9'-1"

532 LARGE CONFERENCE CPT RB-1 REF C4 / A-401 PT-1 REF C4 / A-401 PT-1 / PT-2 APC / GYP APC-1 / PT-1 9'-1" / 8'-6" 3

533 BREAK ROOM CPT/LVT RB-1 REF D1 / A-401 PT-1 REF C4 / A-401 PT-1 / PT-2 APC / GYP APC-1 / PT-1 9'-1" / 8'-6" 1

540 IT OPEN OFFICE ESD RB-1 PT-1 PT-1 / GLAZ PT-1 PT-1 APC APC-1 / PT-1 9'-1" / 8'-6"

541 IT OFFICE CPT RB-1 PT-1 PT-1 / -- PT-1 PT-1 APC APC-1 9'-1"

542 IT WORKROOM EXIST EXIST PT-1 PT-1 PT-1 PT-1 EXIST EXIST EXIST 2

543 SERVER EXIST EXIST PT-1 PT-1 PT-1 PT-1 EXIST EXIST EXIST 2

550 USDA SWING SPACE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST

551 USDA TEMPORARY STORAGE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST

5150 ELECTRICAL EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST

6" = 1'-0"A2

FLOOR TRANSITION DETAIL

6" = 1'-0"

1" 2" 4" 6"

1/4" = 1'-0"A1

TYPICAL DMP-1 FINISH APPLICATION

A-601A-601

U.S. DEPARTMENT OF AGRICULTURE

WASHINGTON, D.C. 20250

DEPARTMENTAL REGULATION

Number:

3902-001

DATE:

June 30, 2009

SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies’ (SCA) Computer Rooms OPI: The Office of the Chief Information

Officer (OCIO) International Technology Services (ITS) – Infrastructure Definition Division (IDD), Architecture Definition Branch (ADB)

Section Page

1. PURPOSE

2. SPECIAL INSTRUCTIONS/CANCELLATIONS

3. AUTHORITY/REFERENCES

4. SCOPE

5. RESPONSIBLITIES

6. COMPUTER ROOM PHYSICAL AND SECURITY REQUIREMENTS

7. COMPUTER ROOM ENVIRONMENTAL REQUIRMENTS

8. DEDICATED ELECTRICAL CIRCUITS AND OUTLETS FOR ADP EQUIPMENT

9. PLYWOOD

10. TELEPHONE SYSTEM

11. DISTRIBUTION CLOSETS AND CABLE PATHWAYS

12. DATA CABLING/TELECOMMUNICATIONS

13. LAN/WAN/VOICE CABINET

14. COPIES OF RELATED DOCUMENTS

15. INQUIRIES

16. ABBREVIATIONS/DEFINITIONS

47PK05-18R0015 EXHIBIT 2

DR 3902-001 June 30, 2009

1. PURPOSE

This Regulation provides the wiring and cabling requirements to be incorporated when renovating or constructing new computer rooms for all Service Center Agencies (SCA):

Farm Service Agency (FSA), Natural Resources Conservation Service (NRCS), the Rural Development (RD) mission area, and the Office of the Chief Information Officer (OCIO) International Technology Services (ITS).

2. SPECIAL INSTRUCTIONS/CANCELLATIONS

a. Effective Date. The Wiring/Cabling Specifications will become effective immediately upon issuance of this Regulation.

b. Series Replaced. Not applicable.

c. Directives Rescinded. Not applicable.

3. AUTHORITY/REFERENCES

a. National Communications System (NCS) Federal Telecommunications Recommendation (FTR), FTR1090-1997: Commercial Building Telecommunications Cabling Standard.

b. American National Standards Institute (ANSI)/Telecommunications Industry Association (TIA)/Electronic Industries Alliance (EIA)-568: Commercial Building Telecommunications Wiring Standard.

c. ANSI/TIA/EIA-569: Commercial Building Standard for Telecommunications Pathways and Spaces.

d. ANSI/TIA/EIA-570: Residential and Light Commercial Telecommunications Wiring Standard.

e. ANSI/TIA/EIA-606: Administration Standard for the Telecommunications Infrastructure of Commercial Buildings.

June 30, 2009 DR 3902-001

f. ANSI/TIA/EIA-607: Commercial Building Grounding and Bonding Requirements for Telecommunications.

g. ANSI/TIS/EIA-942: Telecommunications Infrastructure Standard for Data Centers.

4. SCOPE

The specifications in this regulation shall be used for all OCIO-ITS and SCA space planning. The Automated Data Processing (ADP) room standards will be applied to all offices receiving ITS services, including those offices where no ITS staff is co-located.

These specifications define a baseline primarily for SCA field service centers. The requirements for state, regional, national offices and other organizational units may be unique and may require higher performance or additional space and power. Deviations from this baseline will be decided on a case by case basis at the time of a major renovation or solicitation of new space.

5. RESPONSIBLITIES

a. The Technical Support Division (TSD) Group Manager will:

(1) Provide oversight for all ADP room cabling and/or wiring installation.

(2) Verify that all required certifications are received.

b. The Service Center Leasing Agent will:

(1) Ensure that the specifications in this Regulation are included in solicitations for offers or lease amendments, as appropriate.

(2) Keep all certifications as part of the official lease file.

c. Clearing and Approving Officials:

(1) The TSD Group Manager will approve all final wiring cable plants before installation begins.

d. The Infrastructure Operations Division (IOD) Telecommunications Operations Branch (TOB) will:

(1) Provide the Group Manager with any needed technical assistance.

6. COMPUTER ROOM PHYSICAL AND SECURITY REQUIREMENTS

Refer to Departmental Regulation (DR) 3901-001, ITS Space Standards for the physical and security requirements for the computer room.

7. COMPUTER ROOM ENVIRONMENTAL REQUIRMENTS

When cable consists of multiple runs, the Lessor shall provide cable trays or J-hooks to insure that the cable does not come into contact with the suspended ceiling.

8. DEDICATED ELECTRICAL CIRCUITS AND OUTLETS FOR ADP EQUIPMENT

a. Computer Room Circuits. Provide and install dedicated electrical circuits with isolated grounds in the Computer Room. Dedicated circuits must be 110 volt, 20-ampere standard three-prong circuits with true earth ground terminated into orange or other uniquely marked (“computer use only”) duplex outlets. Provide and install duplex outlets for each dedicated electrical circuit in the Computer room. Dedicated electrical circuits will be used for the telephone systems. The main electrical panel for the computer/voice (if computer/voice is available) equipment will be properly grounded to meet TIA/EIA and Federal Information Processing Standards (FIPS).

b. General Office Space Circuits. Provide dedicated electrical circuits with multiple outlets at designated locations throughout the service center with multiple outlets to accommodate the peripheral equipment (i.e. computer workstations, printers).

c. Electrical Requirements for Uninterruptible Power Supply (UPS) Circuit. Critical servers are required to be connected to the UPS.

(1) Uninterruptible Power Supply (UPS). Dedicated Circuits will be required for use by UPS.

(2) Number and Type of Circuits. There will be a minimum of 2 (two) 120 volt, 30 amp minimum with true ground, terminated into a twisting-lock receptacle.

Each dedicated circuit must have insulated, isolated earth ground; conduit ground is not acceptable.

(3) Receptacle. The receptacle will be a NEMA L5-30R twist-locking receptacle.

(4) Location of the UPS receptacle. The UPS receptacle will be located in the ADP/Computer room where the Local Area Network (LAN)/Wide Area Network (WAN)/Voice (LWV) cabinet is installed. The receptacle will be located within a maximum of 4.5 feet from the back of the United States Department of Agriculture (USDA) wiring cabinet.

9. PLYWOOD

One sheet of ¾ inch 4 x 8 foot plywood shall be vertically mounted on the wall in the Computer Room within 3 feet of an electrical outlet and the wiring cabinet. The backboard should be attached to the wall using correct mounting hardware and procedures. If the wall is sheet-rocked, attach the backboard to the studs. If the wall is concrete, attach the backboard using anchors. The backboard should be painted with fire retardant paint the same color as the interior walls of the building. This will be the extended demarcation point and for the installation of phone equipment.

10. TELEPHONE SYSTEM

A telephone demarcation point (D-mark) must be provided on a type 66S block on the backboard for all telephone lines prior to the move date. The telephone system will be moved by USDA to a new office and will be installed by USDA technicians during move-in.

11. DISTRIBUTION CLOSETS AND CABLE PATHWAYS

Facilities requiring multiple distribution points within the building or on multiple floors will comply with ANSI/TIA/EIA-569-B standards.

12. DATA CABLING/TELECOMMUNICATIONS

a. General Specifications. All premise data/telecommunications cabling will comply with TIA/EIA-568-B. All new installations will use Category 6 cabling, as specified in TIA/EIA-568-B.2-1, or higher. All cabling will meet local building codes.

b. Exceptions. Renovations to buildings which currently comply with TIA/EIA-568-A and contain Category 5 cable and terminations may continue to use Category 5 wiring and terminations as specified in TIA/EIA-568-A.

All substantial additions to, or replacements of, existing wiring should comply with the specifications in 12(a) where possible.

NOTE. Category 5 wiring is unsuitable for Ethernet speeds above 100 Mb/sec.

c. Copper Cable Installation.

(1) Provide, place, terminate and test Cat-6 certified 100-ohm Balanced Twisted Pair cables according to applicable standards.

(2) Data cable and voice cables shall be terminated with Cat-6 compliant terminations (patch panels, wall outlets, etc.).

(3) All Balanced Twisted Pair cables shall be terminated using the T568A pin/pair assignments as specified in TIA/EIA-568-B and per FTR 1090-1997.

d. Copper Cable Specification. All cable equipment and materials must be manufactured by facilities that are International Organization for Standardization (ISO) 9001 registered and certified as follows:

(1) Shall be Cat-6 or Cat-6a rated in accordance with ANSI/TIA/EIA-568-B.

(2) Shall be four-pair, balanced, 100-Ohm, 24 American Wire Gage (AWG).

(3) The selected cable must have contiguous, two-foot segment-length markers printed on the cable jacket. The markings must also show cable manufacturer, cable model number or name, cable part number, Cat-6 or Cat-6a designation, a UL or ETL verification designation, a CMP type, and a “tested to 350 MHz” or above designation.

(4) Shall be tested and certified by the installer to comply with the previous requirements.

e. Data Fiber Cable Installation.

(1) Fiber optic cable shall be used for all links in excess of 90 meters and where appropriate. There shall be no 90º bends in any fiber cables with a radius of less than three (3) inches.

(2) All fiber cable links less than 500 meters shall be 6-strands, multimode optical fiber cable.

(3) All Optical Fiber, Conductive, Plenum (OFCP) or Optical Fiber Conductive Riser (OFCR) rated fiber cable shall be properly grounded at both ends and may not be installed in the same cable tray or conduit as power cables.

(4) All ANSI/TIA/EIA–568-B requirements for fiber cable installation, testing, and termination will be observed.

(5) All strands of each fiber cable shall be terminated at each end of the cable, with either Straight Tip (ST) or Standard Connector (SC) connectors, as appropriate to the related equipment interface connector, and will be conveyed to the selected cable contractor upon request.

FIGURE 1 FIGURE 2

SC Connector ST Connector

(6) Supply several sets of fiber patch cords that should not only serve immediate switch connection concerns, but allow for possible switch update connections in the future. The unused fiber patch cables will be kept in reserve at this site, in the event that such switch updates do occur.

f. Data Fiber Cable Specifications.

(1) All fiber cable shall be 6-strand, multimode, tight buffered, 50 x 125 µm optical fiber, rated OFCP or OFCR as appropriate, and must be clearly marked as such on the cable sheathing.

(2) All fiber link cable runs, shall be run within orange, plenum rated inter-duct, and appropriately sized according to the number of fiber runs to be contained.

(3) Both the fiber cable sheathing and the protective inter-duct shall be colored orange to denote multimode fiber.

g. Wall Input/Output (I/O) Face Plates for Work Area I/O Connections. Work areas will have a quad or hex outlet plate connector with four or six RJ-45 connectors (see diagram). Extra outlet plate connectors will also be required in some common areas.

All drops will be identified and numbered on the office floor plan prior to installation.

Each of the four or six connectors will be cabled with 4-pair balanced twisted-pair cable. The data cables will be category 6 as listed in the cable specification block.

These cables will be terminated with RJ-45 connectors at the device end. The other end will be punched down on an RJ-45/110-type patch panel in the LWV wiring cabinet. Each quad plate MUST be labeled with the work station number (1, 2, etc.)

and the A, B, C etc. format. Each connection MUST be identified as (1A, 1B, 2A, 2B, etc.) on the corresponding patch panel location.

FIGURE 3 FIGURE 4

Quad Plate Hex Plate

Ports A, B, C – Data Ports A, B, C, D, E – Data

Port D – Phone Port F – Phone

13. LAN/WAN/VOICE CABINET

The Government will provide the LAN/WAN/VOICE cabinet, and a cable installation contractor will provide and install the wiring, cabling, and patch panels in the cabinet as specified by the TSD Group Manager. Patch panels will be RJ-45/110 type and appropriately-sized, based upon the number of quad and/or hex outlet plates. A wire service loop that will allow the cabinet to freely move a minimum of six feet in any direction will be installed by the cable installation contractor as part of the cable installation. The RJ-45/110 type patch panel must be mounted in the cabinet in the place designated by the TSD Group Manager.

14. COPIES OF RELATED DOCUMENTS

a. Copies of FTRs. Copies of FTRs are available from:

The National Communications System (NCS), Technology and Standards Division (N6)

701 South Court House Road

Arlington, Virginia 22204-2198

Telephone (703) 607-6204

b. Copies of the specifications and related documents. Copies of the specifications and related documents can be obtained from:

(1) Global Engineering Documents

15 Inverness Way East

Englewood, Colorado 80112

Telephone (800) 854-7179 or (303) 397-7956

(2) National Resource for Global Standards, www.nssn.org.

15. INQUIRIES

Direct all questions concerning this notice to OCIO, ITS, Infrastructure Operations Division (IOD), Telecommunications Operations Branch (TOB).

http://www.nssn.org/

16. ABBREVIATIONS/DEFINITIONS

ADB Architecture Definition Branch

ADP Automated Data Processing

ANSI American National Standards Institute

EIA Electronics Industry Association

FIPS Federal Information Processing Standards

FTR Federal Telecommunications Recommendations

GWAC General Services Administration Wiring and Cabling Contract

IDD Infrastructure Definition Division

IOD Infrastructure Operations Division

ITS International Technology Services

LWV Local Area Network (LAN)/Wide Area Network (WAN)/Voice

NCS National Communications System

SCA Service Center Agencies

TIA Telecommunications Industry Association

TOB Telecommunications Operation Branch

-END-

E

A

B

C

D

D5 D5 D5 D5

D5

D10

USDA SWING SPACE

USDA TEMPORARY STORAGE

D2

D2

D2

D1

D4

SERVER

D11

DEMOLITION PLAN GENERAL NOTES

1. DARK, DASHED LINES INDICATE EXISTING CONSTRUCTION WITH ASSOCIATED DOORS,

FRAMES, AND MILLWORK TO BE FULLY REMOVED. EXISTING FIRE ALARM NOTIFICATION

AND MONITORING DEVICES AT PARTITIONS TO BE REMOVED TO BE CAREFULLY SALVAGED

IN PLACE FOR REUSE AT FINAL PLAN. NEATLY COIL WIRES AND INDIVIDUALLY SUSPEND

FROM SLAB ABOVE FOR FUTURE RE-INSTALLATION. COORDINATE WITH ENGINEERING

DOCUMENTS.

2. SOLID, FILLED LINES INDICATE EXISTING PARTITION CONSTRUCTION TO REMAIN UNLESS

OTHERWISE NOTED. REMOVE EXISTING WALLCOVERING IF PRESENT. PATCH AND REPAIR

WALLS TO REMAIN AS REQUIRED FOR “LIKE NEW” CONDITION. PROTECT DURING ALL

PHASES.

3. FOR AREA OF TENANT SUITE RENOVATION, REMOVE ALL PARTITIONS, DOORS, FRAMES,

MILLWORK AND FINISHES FOR FULL EXTENT. FULLY REMOVE EXISTING CEILING

ASSEMBLIES, LIGHT FIXTURES AND ABOVE CEILING MEP BRANCH ELEMENTS AS REQUIRED

BY NEW WORK. SCOPE IS NOT FULLY ILLUSTRATED ON PLAN--COORDINATE WITH ON-SITE

EXISTING CONDITIONS FOR ACTUAL SCOPE. FINAL DEMOLITION TO LEAVE SITE "BROOM

CLEAN." PREPARE ALL REMAINING SURFACES SMOOTH AND READY TO RECEIVE NEW

FINISHES.

4. REMOVE EXISTING FLOORING FINISH MATERIALS AND ASSOCIATED WALL BASE FOR FULL

PROJECT SCOPE, UNLESS SPECIFICALLY NOTED OTHERWISE. SELECTIVELY REPAIR,

INCLUDING SKIM COATING AS NECESSARY, GWB PARTITIONS AND COLUMN SURROUNDS

SLATED TO REMAIN SMOOTH TO ELIMINATE EVIDENCE OF BASE REMOVAL PROCESS.

5. REMOVE EXISTING BASE CABINET AND WALL CABINET MILLWORK WITH ASSOCIATED

CLEATS AND ANCHORS. WHERE MILLWORK EXPOSES AN EXISTING PARTITION FACE TO

REMAIN, PATCH PARTITION SMOOTH TO PROVIDE “LEVEL 4” FINISH AND TO ELIMINATE

EVIDENCE OF FORMER MILLWORK ATTACHMENTS. PREPARE FOR NEW WALL BASE

INSTALLATION.

6. ANY GYPSUM BOARD COLUMN FURRING TO REMAIN UNLESS OTHERWISE NOTED.

7. "PASS THROUGH" BUILDING SYSTEMS (PIPING, CONDUIT, ETC.) SERVING OTHER FLOORS,

ARE TO REMAIN, UNLESS OTHERWISE NOTED. PARTITION AND FURRING CONSTRUCTION

LOCATED AT PASS THROUGH LOCATIONS TO REMAIN, UNLESS OTHERWISE NOTED.

8. WHERE ELECTRICAL RECEPTACLES, COMMUNICATION RECEPTACLES, CARD ACCESS

READERS, LIGHT FIXTURES, THERMOSTATS OR SIMILAR DEVICES ARE TO BE REMOVED IN

PARTITIONS TO REMAIN, PATCH SMOOTH EXISTING PARTITION TO ELIMINATE EVIDENCE OF

FORMER LOCATION.

9. DO NOT CUT OR REMOVE STRUCTURAL STEEL, STRUCTURAL CONCRETE, OR LOAD

BEARING UNIT MASONRY WITHOUT WRITTEN APPROVAL OF TENANT REPRESENTATIVE.

10. REMOVE ALL EXISTING ROOM IDENTIFICATION AND MISCELLANEOUS DIRECTORY OR

INFORMATIONAL SIGNAGE FROM PREVIOUS TENANT FIT-OUT. EXISTING LIFE SAFETY,

EVACUATION, ELEVATOR, AND CODE REQUIRED SIGNAGE TO REMAIN. WHERE SIGNAGE

REMOVAL EXPOSES AN UNFINISHED SURFACE TO REMAIN, PATCH SURFACE SMOOTH TO

RECEIVE NEW FINISHES. SURRENDER REMOVED SIGNAGE TO CLIENT FOR REUSE WHERE

POSSIBLE.

11. PREPARE FOR NEW FLUSH FLOOR CORES TO COORDINATE WITH NEW FREE-STANDING

MILLWORK OR FURNITURE. PROVIDE LOCALIZED CORE DRILLS FOR NEW POKE-THRUS OR

SAW CUTS AND REINFORCEMENT FOR RECESSED FLOOR BOX ASSEMBLIES. COORDINATE

WITH ENGINEERING DRAWINGS. REFERENCE FURNITURE PLAN.

12. WHERE DEMOLITION EXPOSES FLOOR SLAB OPENINGS, REPAIR TO MATCH EXISTING

CONSTRUCTION. CONFIRM/COORDINATE WITH STRUCTURAL DRAWINGS FOR OPENINGS

OVER 1' - 0".

13. PROTECT BASE BUILDING HVAC SYSTEM FROM DUST DURING ALL PHASES.

14. PROTECT EXISTING PARTITION, FLOOR, ELEVATOR, AND CEILING FINISHES BEYOND

CONTRACT AREA FROM DAMAGE DURING ALL PHASES.

15. PROTECT EXISTING SMOKE DETECTORS, EMERGENCY STROBES, EMERGENCY FIRE PULLS,

AND ALL OTHER CONTROL, MONITORING OR NOTIFICATION DEVICES DURING ALL PHASES.

COORDINATE WITH CONSTRUCTION DOCUMENTS AND BUILDING REPRESENTATIVE FOR

ADDITIONAL INFORMATION AND RESTRICTIONS.

16. EXISTING SPRINKLER SYSTEM TO REMAIN. REFERENCE FIRE PROTECTION DRAWINGS FOR

MODIFICATION SCOPE. PROTECT DURING ALL PHASES. COORDINATE WITH

CONSTRUCTION DOCUMENTS AND TENANT REPRESENTATIVE FOR SPRINKLER

RESTRICTIONS.

17. AT AREAS OF FLOOR FINISH REMOVAL, ADDITIONALLY PREPARE SLAB SMOOTH AND FLUSH

TO ACCOMMODATE INSTALLATION OF NEW SCHEDULED FINISH FLOOR MATERIALS.

PREPARATION TO INCLUDE SELECTIVE FLOOR GRINDING, BEAD BLASTING, AND FLASH

PATCHING AS REQUIRED TO YIELD A SMOOTH AND LEVEL SUB SURFACE.

18. AT FIRE EXTINGUISHERS TO BE REMOVED, SALVAGE INVENTORY, IF ANY, AND STORE FOR

REUSE AT FINAL PLAN. FULLY CLEAN, REPAIR AND RECHARGE EXTINGUISHER CANISTERS

PRIOR TO RE-INSTALLATION

19. PROTECT EXISTING WINDOW BLINDS DURING CONSTRUCTION. CLEAN AT END OF PROJECT.

ANY DAMAGE CREATED FROM REMOVAL/REINSTALLATION MUST BE REPAIRED.

20. ANY FURNITURE OR EQUIPMENT LEFT BEHIND IN DEMO AREA TO BE REMOVED AND

DISPOSED OF AS PART OF CONSTRUCTION CONTRACT.

21. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION

REQUIREMENTS.

22. REMOVE ALL EXISTING AV EQUIPMENT AND STORE IN USDA TEMPORARY STORAGE ROOM

551 FOR REINSTALLATION.

DEMOLITION PLAN KEYED NOTES DEMOLITION PLAN LEGEND

EXISTING PARTITION TO REMAIN

EXISTING DOOR TO REMAIN

EXISTING PARTITION / DEVICES TO BE DEMOLISHED

EXISTING DOOR TO BE DEMOLISHED

GIVE BACK SPACE

AREA NOT IN SCOPE

D

C

B

A

1 2 3 4 5

ISSUE FOR CONSTRUCTION (100%)

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Jacobs Project No.:

Scales:

P H

O E

N

IX

F E

D E

R A

L B

U

IL

D

IN

G A

N D

C O

U R

T H

O U

S E

N

S T

A V

E N

U E th F

L O

O R

P H

O E

N

IX

A

Z

U S

D A

N R

E

R

IO

R S

P A

C E

R E

D U

C T

IO

N

F5Y65908

15 DEC 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

B

IM

/U

S -F

Y

-U

S D

A N

R S

C /U

S -F

Y

-U S

D A

N R

S C

-A R

C H

-V .r v t

/1

/2

:3

:0

A

M

AD101MJB

LEV

MLW

ARCHITECTURAL

DEMOLITION

FLOOR PLAN

1/8" = 1'-0"A1

DEMOLITION FLOOR PLAN

D1 REMOVE EXISTING PLUMBING FIXTURE AND PIPING. CAP LINES AT SOURCE AS REQUIRED.

EXISTING VALVES TO REMAIN.

D2 PROVIDE PHYSICAL BARRIER BEFORE NEW DEMISING WALL IS BUILT. PROTECT EXISTING

SPACE THAT IS NOT A PART OF GIVE BACK SPACE.

D4 REMOVE EXISTING CASEWORK.

D5 REMOVE SECTION OF EXISTING PARTITION CONSTRUCTION AT LOCATION OF NEW ENTRY

ALCOVE. COORDINATE WITH ARCHITECTURAL PLAN.

D10 REMOVE EXISTING DOOR AND SIDELIGHT AND SALVAGE FOR REINSTALLATION AT IT

OFFICE.

D11 REMOVE EXISTING DOOR AND SALVAGE CIPHER LOCK FOR REINSTALLATION

1/8" = 1'-0"

24'4' 8' 16'

N

47PK05-18R0015 EXHIBIT 3

vierrele Placed Image

MichelleKMaestas Polygon

MichelleKMaestas Polygon

MichelleKMaestas Line

Amend_02
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
181001_USDA_Phoenix_Addendum No. 1
Sheets
AD101 - DEMOLITION FLOOR PLAN
Exhibit 2 DR3902-001
PURPOSE
SPECIAL INSTRUCTIONS/CANCELLATIONS
Effective Date. The Wiring/Cabling Specifications will beco