Interview_Room_DG_Excerpt.pdf
PDF 87 KB Posted
- Attached to
- Port upgrades Federal contract opportunity
- Solicitation number
- 47PJ0019R0087
About this file
Interview room design guide
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RESPONSE_TO_QUESTIONS_5_23_19.pdf | ||
| RESPONSE_TO_QUESTIONS_5_16_19.pdf | ||
| Amendment_0002.pdf | ||
| RESONSE_TO_QUESTIONS_5_13_19.pdf | ||
| Amendment_0001.pdf | ||
| RESPONSE_TO_QUESTIONS.pdf | ||
| CAVSS_DESIGN_GUIDE_STANDARDS_Final_2014.pdf | ||
| SBU_Information_Request_Form.pdf | ||
| solicitation-PembinaLPOE.pdf | ||
| Reference_Form.pdf | ||
| St_John_Door_Location.pdf | ||
| USR_v21_6_8_18.pdf | ||
| Booth_LPOE_DG_Excerpt.pdf | ||
| Pembina_-_Port_Upgrades_SOW.pdf | ||
| ND26_3_15_19.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For Official Use Only
The Interview Room is used by CBP Officers to conduct interviews of detainees suspected of violations or criminal activity.
Interview Room is located within the violator processing and enforcement area. The room shall be directly accessible from the violator waiting/processing area, and in close proximity to the search room and holding rooms. Windows/side vision panels must be provided in the walls between the interview room and the adjacent violator waiting area for maximum visibility. Visibility requirements preclude compromising situations between detainees and officers in one-on-one interviews.
Interview Room must not open directly onto Processing or Admin areas.
Cruise: provide fixed chairs in lieu of bench, no requirement for handcuff rings or bars.
3.1 VIOLATOR ENFORCEMENT AREAS
Sprinkler Head Type:
SPKLR-09 Detention Grade Pendant
Door Type: D-02 Detention Grade, 12 Ga HM, 2" thick, Half-glass, seamless, 180° Outswing
Door Frame: HM-3 Detention, 12 gauge, fully welded, grouted into CMU
Exterior Windows:
N/A
Exterior Window / Door Glazing:
GL-06 Laminated, Mirrored, (one-way) glazing
Special Requirements:
Provide at Air and Cruise only: Type D solid door with 12"W x 36"H, sidelight.
Fire Special Requirements:
See Fire Protection chapter for special detention grade sprinkler requirements.
Fixtures and Fittings 1:
FD-2: Floor Drains - Vandal proof, 6"
Fixtures and Fittings 2:
Fixtures and FIttings 3:
Fixtures and Fittings 4:
Fixtures and Fittings 5:
Fixtures and Fittings 6:
Fixtures and Fittings 7:
Plumbing Special
Acoustic Separation:
NIC 46: Moderate sound isolation. Very loud sounds can be faintly heard
Floor Finish: FF-10 Seamless epoxy-resin flooring system, slope to Floor drain(s).
Base: BF-04 Integral with seamless flooring, 8" H
Wall Construction:
Wall-08 CMU - 8"
Wall Finish: WF-15: Paint, Epoxy, Semi-gloss
Ceiling Remark: Installation of wire mesh must be inspected by CBP prior to covering.
Ceiling Const. / Finish:
CF-15 Gypsum Board over 9 Ga Expanded Wire Mesh, 5/8" Regular, adhered acoustic tile
Ceiling Height: 9' min
Alternate Construction:
Walls: Glazed CMU Ceiling: 6" slab with Max Security double metal perforated panel.
Const Special Requirements:
CMU Partitions extend to structure above.
Supply Register: S-6: Security Diffuser Return Register: RR-4: Security Exhaust Grille Temp Summer 75° (min) Temp Winter 72° (max) Temp Control: Zone: Control located outside of room Humidity Range: 30% to 60% Special Security: Provide with ½” steel bars 6” OC each way for any openings over 96 Square Inches.
Mech Special Requirements:
Room at negative pressure, 100% exhaust, 10 Air changes minimum.
Fixed Equipment 1:
Handcuff bars or recessed rings, Steel, securely anchored to bench or table
Fixed Equipment 2:
Chair, bolted to floor, Table, Mar-resistant, 60"L x 30"W x 30" H
Receptacles: R-6: Receptacle, Standard GFCI
Electrical Special
Receptacle located on CBP Officer side of table for computer and recording equipment.
Lighting Fixture: L-10: Lighting Fixture, Recessed Mounted Detention Grade
Fixture Types Optional/Special:
L-11: Lighting Fixture, Surface Mounted Detention Grade
Lighting Control: LC-1: Light Switch, located outside of room, LC-3:
Occupancy Sensor
Lighting Special Provide 30 FC at 36" AFF.
Occupancy light outside of room.
DIV 08 - DOORS AND WINDOWS Chapter 14
ROOM OCCUPANCY
2 Staff + 1 Interviewee
ROOM SIZE:
100 SF
DIV 22 - PLUMBING Chapter 17
DIV 23 - MECHANICAL Chapter 18DIV 09 - CONSTRUCTION AND FINISHES Chapter 14
DIV 10 - FIXED EQUIPMENT Chapter 14
DIV 27 - LIGHTING
DIV 26 - ELECTRICAL
Door Lockset Group:
B Mortise Lever Lockset w/ Thumb Turn - Entrance Function
Door Hardware Cylinder:
A-1: Cylinder, keyed individually under a CBP Master
Door Hardware Group:
B Automatic Door Bottom, D Door Stop, E Door Threshold
Interior Window: Hollow Metal Frame, Painted, Tempered Mirrored (one-way) glazing
Other Electrical Receptacles:
Cruise
Express Cargo
Airport
LPOE
Fixed Equipment 3:
Chair for Officer. For detainee: Bench, Fixed, Stainless Steel Detention Grade, 5'L x 16"D x 16"
Mail Office
Room Code:
VPE-007
Chapter 19
Chapter 19
DIV 21 - FIRE SUPPRESSION Chapter 16
Interview Room
ROOM SIGN 8/27/2014
2:35 PM
Interview Room
ROOM FUNCTION
COMMON DESIGN STANDARD ROOM DATA SHEETS
WARNING: This document is FOR OFFICIAL USE ONLY (FOUO). It contains information that may be exempt from public release under the Freedom of Information Act (5 U.S.C.522). It is to be controlled, stored, handled, transmitted, distributed, and disposed of in accordance with DHS policy relating to FOUO information and is not to be released to the public or other personnel who do not have a valid “need-to-know” without prior approval of an authorized DHS official.
22 - 227
For Official Use Only
Security Special Requirements:
CBP Equipment
Computer(s), Digital audio/video recording equipment, Telephone
CBP Equipment
CBP Equipment
Phone Outlets: Phone 01: Single RJ-11 phone port
Data Outlets: Data 01: Single data port
Communications Special
Locate outlets adjacent to the table, on officer side.
CCTV Camera: Fixed CCTV wide-angle lens camera and microphone, monitored/recorded at CCC.
IDS: N/A
Access Control: N/A
Duress System Recessed detention-grade pushbutton, 6" above table and at door
The interviewee side of the table shall be farthest from the door. Door must meet NFPA requirements for egress.
Handcuff rings/bar on table shall be located to prevent detainees from reaching anything on the table.
Ceiling: Access panels shall be steel detention type w/ lock/special tools for removal.
Flooring at Cruise: Carpet is optional finish Duress System: Connect alarm button to CCC and/or other CBP-designated location. Provide audible/visual signal outside room. Provide keyed reset/dial control outside room adjacent to door.
Lighting: Lighting levels between Interview Room and Violator Processing Area shall be such that viewing through window shall be limited to only outside to inside of room; visibility is to be minimized from inside to outside of room.
Rear Wall: adhered accoustic tile or other sound deadening treatment.
DIV 10 - CBP PROVIDED EQUIPMENT Chapter 14
OTHER REQUIREMENTS DIV 28 - SECURITY Chapter 21
DIV 27 - COMMUNICATIONS Chapter 20
SCHEMATIC PLAN Interview Room VPE-007
COMMON DESIGN STANDARD ROOM DATA SHEETS
WARNING: This document is FOR OFFICIAL USE ONLY (FOUO). It contains information that may be exempt from public release under the Freedom of Information Act (5 U.S.C.522). It is to be controlled, stored, handled, transmitted, distributed, and disposed of in accordance with DHS policy relating to FOUO information and is not to be released to the public or other personnel who do not have a valid “need-to-know” without prior approval of an authorized DHS official.
22 - 228
File details come from the government source that posted it.