4_02829_End_and_Stress_Panels_mvo.doc

DOC document 43 KB Posted

Attached to
RED WASH WETLANDS FENCE
Solicitation number
140L6221R0046
Issued by

View the file

Other files

File Type Posted
Sol_140L6221R0046_Amd_0001.pdf PDF
140L6221R0046_AMD_0001_Question_and_Answer_0001.docx DOCX document
MAPS.pdf PDF
6_Work_Data_Sheet_1_of_2__MVO_6_23_21.docx DOCX document
2__01009_general_mvo.docx DOCX document
7_Work_Data_Sheet_2_of_2_MVO_6_23_21.docx DOCX document
0_Bid_Schedule.xlsx XLSX spreadsheet
Red_Wash_Wetlands_Fence_Drawings.pdf PDF
3_02835_wood_fences_and_gates_mvo.docx DOCX document
Sol_140L6221R0046.pdf PDF
5_Fence_Material_specs_mvo.doc DOC document
1_SOW_mvo.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PAGE

SECTION 02829

FENCE STRESS AND END PANELS

PART 1: GENERAL

1.1

SUMMARY

A. Section Includes: Furnishing and installing stress panels and end panels at the locations as staked in the field.

1.1

PROJECT/SITE CONDITIONS

A. Requirements: Access roads shall not be constructed along fence lines and to the construction site unless written approval is granted by the Contracting Officer. Cross country travel with wheeled or tracked vehicles shall be only to and along fence lines.

PART 2: PRODUCTS

2.1

MATERIALS

PART 3: EXECUTION

3.1

PREPARATION

A. Clearing: Clearing shall be limited to hand clearing. Only vegetation that interferes with the fence shall be removed. All debris shall be disposed of in the immediate vicinity.

3.2

INSTALLATION

A. Stress Panels: Shall be added at where a new roll of wire comes to an end and another roll starts, approximately every 1250 feet, and at points to maintain the integrity of the fence. Stress panels require two opposing brace wires in two sections. Maximum width of 8 Feet and minimum width of 7 Feet for sections. Requiring two opposing brace wires per section, as shown in drawings.

B. End Panels: Maximum width of 8 Feet and a minimum width of 7 Feet panels. Galvanized brace wire shall be wrapped two times around panels, as shown in drawings. Each wrap shall be looped once around the post. The brace wires will then be twisted tight. End panels one brace wire is required. .

PART 4: MEASUREMENT AND PAYMENT

4.1 METHOD OF MEASUREMENT

A. Units: The work described in this section will be measured and paid for as complete units.

4.2 BASIS OF PAYMENT

A. Payment: Prices and payment will be full compensation for the work described in this section. Payment will be made under:

Pay Item

Pay Unit

02829(1) Fence Stress Panels

EA

02829 (2) Fence End Panels

EA

END OF SECTION 02829

Red Wash Wetlands Fence 2021

Fence Stress and End Panels 02829 -

File details come from the government source that posted it. Updated .