Text version
D O
W N
V A N
~ U P
V A N
V A N
37 39
39 41
41 37
37 39
2 (TYP.)
3#10, 1#10 GND, 3/4"C (TYP.)
3#10, 1#10 GND, 3/4"C
(E) 2-L-1D-37,39,41
42 38
38424042
2(TYP.)
3#10, 1#10 GND, 3/4"C (TYP.)
3#10, 1#10 GND, 3/4"C
(E) 4-L-1C-38,40,42 o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
Drawing number
Drawn
Building Number
Location
Project Title
Date
Contract Number
Checked by
Drawing Title
Approved : Project Director
CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management
ARCHITECTURE/
INTERIOR DESIGN:
HDR Architecture, Inc.
3200 E Camelback Road, Suite 350 Phoenix, AZ 85018
Project Number
VA101CFM-P-0159
VA262-16-F-5914
593-15-330
1 2 3 4 5 6
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
7 8 9
U.S. Department of Veterans Affairs
C :\r vt \2
6\
-M E
P -V
A -E
A S
T W
E S
T E
N T
R A
N C
E _C en tr al _J
O E
S T
R A
D A
.r vt
2/ 1/
1:
:5
A
M
ESL101
ELECTRICAL SITE LIGHTING PLAN
AM RE08/30/2017
EAST WEST ENTRANCE
MODIFICATIONS
6900 North Pecos Road North Las Vegas, NV 89086
SHEET NOTES
KEYNOTES
A. FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS REFER TO
DRAWINGS SHEET E001 AND E002.
B. THERE ARE NO LOAD CALCULATION CHANGES DO TO THIS WORK.
1. UTILIZE EXISTING CIRCUITS AND EXTEND AS REQUIRED TO
NEW BOLLARDS.
2. REFER TO ARCHITECTURAL SITE PLAN AND BOLLARD
INSTALLATION DETAIL C6 SHEET AS-100.
3. CONDUIT IN BETWEEN BOLLARDS SHALL BE NEMA TC2 AND TC3,
SCHEDULE 80PVC OR HDPE CONDUIT. CONDUIT SHALL BE
SUITABLE FOR USE WITH 75°C (167°F) RATED CONDUCTORS.
1/16" = 1'-0" A1
ELECTRICAL EAST BOLLARD - PARTIAL SITE PLAN
1/16" = 1'-0" A6
ELECTRICAL WEST BOLLARD - PARTIAL SITE PLAN
NO REVISIONS DATE
1 100% FINAL CONSTRUCTION DOCUMENTS 08/30/2017
2 100% FINAL CONSTRUCTION DOCUMENTS-ADDENDUM 1 02/01/2018
| Sheets |
| ESL101 - ELECTRICAL SITE LIGHTING PLAN |
File details come from the government source that posted it.