36C25919R0061-006.pdf

PDF 595 KB Posted

Attached to
Install Fire Pump Federal contract opportunity
Solicitation number
36C25919R0061
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

About this file

36C25919R0061 6x6x9f1.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Install Fire Pump, newest first.
File Type Posted
36C25919R0061-0003001.pdf PDF
36C25919R0061-0003000.docx DOCX document
36C25919R0061-0002001.pdf PDF
36C25919R0061-0002000.docx DOCX document
36C25919R0061-0001004.jpg JPG image
36C25919R0061-0001003.pdf PDF
36C25919R0061-0001002.pdf PDF
36C25919R0061-0001001.pdf PDF
36C25919R0061-0001000.docx DOCX document
36C25919R0061-0001005.jpg JPG image
36C25919R0061-003.pdf PDF
36C25919R0061-005.pdf PDF
36C25919R0061-001.docx DOCX document
36C25919R0061-004.pdf PDF
36C25919R0061-009.docx DOCX document
36C25919R0061-008.pdf PDF
36C25919R0061-007.pdf PDF
36C25919R0061-002.pdf PDF
36C25919R0061-000.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FP 2.1

March 08

Supersedes all previous issues

A-C FIRE PUMP SYSTEMS

Dimensions – Horizontal Electric

Motor Driven Fire Pumps

(H)6x6x9F – 8100 SERIES

MOTOR

FRAME C MO HB HF HF1 HD HG

23.30 [592]

25.00 [635]

7.10 [181]

60.00 [1524]

48.00 [1220]

24.00 [610]

18.25 [464]

4.00 [102]

24.80 [630]

26.30 [669]

7.80 [199]

28.20 [717]

29.70 [755]

8.60 [219]

30.00 [762]

31.00 [788]

9.20 [234]

36.40 [925]

37.90 [963]

10.40 [265]

NOTES:

1. ALL DIMENSIONS ARE INCHES [mm].

2. SUCTION AND DISCHARGE CONNECTIONS ARE DRILLED PER 125# ANSI B16.1. PUMPS WITH “H” PREFIX HAVE DISCHARGE CONNECTION

DRILLED PER 250# ANSI B16.1. FLANGE HOLES STRADDLE CENTERLINE.

3. BASE PLATE SETTING (BEFORE PIPING), GROUTING PROCEDURES, AND FINAL ALIGNMENT MUST BE IN ACCORDANCE WITH A-C FIRE

PUMPS SYSTEMS RECOMMENDED PROCEDURES OUTLINED IN THE INSTRUCTION MANUAL ASSOCIATED WITH THIS PUMP TYPE.

4. MOTOR DIMENSIONS ARE APPROXIMATE FOR A GIVEN NEMA FRAME. CONSULT FACTORY IF SPACE IS LIMITED.

5. BOTH SUCTION AND DISCHARGE PIPES MUST BE SUPPORTED INDEPENDENTLY NEAR THE PUMP TO REDUCE STRAIN ON THE PUMP CASING.

ALSO EXPANSION JOINTS, IF USED, MUST NOT EXERT FORCE ON CASING.

6. COUPLING GUARD MEETS ANSI/OSHA REQUIREMENTS.

7. CONSULT FACTORY FOR BASE MOUNTED CONTROLLER.