BLDG 204 - 2ND FLOOR-RECORD-Work.pdf

PDF 236 KB Posted

Attached to
Y1DA--Replace PA System Bldg. 163 and 204 674-22-262 CTVHCS
Solicitation number
36C25722B0022
Issued by

About this file

This document provides floor plans and space details for the second floor of Building 204 at the Temple VA Medical Center in Temple, Texas. Key areas include patient rooms, nursing stations, support spaces for pharmacy, nutrition, electrical and mechanical rooms. The related federal contract opportunity is solicitation number 36C25722B0022 from the Department of Veterans Affairs to replace the public address system in Buildings 163 and 204 at the Central Texas Veterans Health Care System for $674,222. The opportunity type is a solicitation and responses are due by the date specified in the solicitation document. The work includes removing the existing PA systems and installing new networked audio systems to provide emergency notifications and general paging across the two buildings.

View the file

Other files

File Type Posted
36C25722B0022 0002.docx DOCX document
163-4.pdf PDF
BLDG 204 - 4TH FLOOR-RECORD-Work.pdf PDF
270511 COMMUNICATIONS INSTALLATIONS.docx DOCX document
01 00 00 General Construction.doc DOC document
BLDG 204 - 5TH FLOOR-RECORD-Work.pdf PDF
26 05 11 Electrical installation.doc DOC document
BLDG 204 - BASEMENT - RECORD-Work.pdf PDF
BLDG 204 - 6TH FLOOR - RECORD-Work.pdf PDF
26 05 26 Grounding and Bonding Electrical.doc DOC document
36C25722B0022 0001.docx DOCX document
26 27 26 Wiring for Low Voltage Devices.doc DOC document
07 84 00 Fire Stopping.doc DOC document
280513 CABLES FOR ELECTRONIC SAFETY AND SECURITY.doc DOC document
163-3.pdf PDF
163-2.pdf PDF
28 16 00 INTRUSION DETECTION SYSTEM.doc DOC document
163-B.pdf PDF
BLDG 204 - 1ST FLOOR-RECORD-Work.pdf PDF
BLDG 204 - 3RD FLOOR-RECORD-Work.pdf PDF
26 05 21 Low Voltage.doc DOC document
163-5.pdf PDF
27 51 16 PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS.docx DOCX document
163-1.pdf PDF
36C25722B0022_1.docx DOCX document
01 00 00 General Construction.pdf PDF
26 05 11 Electrical installation.pdf PDF
26 05 21 Low Voltage.pdf PDF
270511 COMMUNICATIONS INSTALLATIONS.pdf PDF
28 16 00 INTRUSION DETECTION SYSTEM.pdf PDF
26 27 26 Wiring for Low Voltage Devices.pdf PDF
280513 CABLES FOR ELECTRONIC SAFETY AND SECURITY.pdf PDF
26 05 26 Grounding and Bonding Electrical.pdf PDF
07 84 00 Fire Stopping.pdf PDF
27 51 16 PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

167.59 SF

STAIR 9

2S-9

62.66 SF

PATIENT

ROOM

2K28A

306.97 SF

PATIENT

ROOM

2K27

200.65 SF

PATIENT

ROOM

2K28

69.94 SF

BATHROOM

2K26A

70.86 SF

BATHROOM

2K29A

302.12 SF

PATIENT

ROOM

2K26

194.28 SF

PATIENT

ROOM

2K29

193.35 SF

PATIENT

ROOM

2K30

302.93 SF

PATIENT

ROOM

2K25

71.02 SF

BATHROOM

2K24A

75.01 SF

BATHROOM

2K30A

658.21 SF

NURSING

UNIT 2K

CORRIDOR

C2-8

298.63 SF

PATIENT

ROOM

2K24

192.45 SF

PATIENT

ROOM

2K31

191.86 SF

PATIENT

ROOM

2K32

302.32 SF

PATIENT

ROOM

2K23

70.59 SF

BATHROOM

2K23A

74.59 SF

BATHROOM

2K32A

97.77 SF

SOIL UTILITY

2K22

207.05 SF

PATIENT

ROOM

2K33

76.14 SF

CLEAN LINEN

2K21

72.48 SF

BATHROOM

2K17A

72.42 SF

BATHROOM

2K15A

72.49 SF

BATHROOM

2K13A

183.55 SF

EQPT. / W.C.

STORAGE

OXYGEN

2K20

301.13 SF

PATIENT

ROOM

2K13

298.82 SF

SWAMP

2K14

301.6 SF

PATIENT

ROOM

2K17

298.77 SF

PATIENT

ROOM

2K16

300.45 SF

PATIENT

ROOM

2K15

293.7 SF

PATIENT

ROOM

2K18

429.6 SF

NURSING

UNIT 2K

CORRIDOR

C2-6

7.2 SF

CRASH CART

XXXX

1,307.61 SF

MECHANICAL

ROOM

2K12

89.94 SF

CLEAN

UTILITY

2K19

13.62 SF

EQUIPMENT

STATION

XXXX

773.34 SF

NURSING

UNIT 2K

CORRIDOR

C2-5

170.56 SF

STAFF

LOUNGE

2K34

441.58 SF

NURSING

UNIT 2K

2K

51.87 SF

ISOLATION

2K06B

71.25 SF

PHARMACY

2K05

50.51 SF

NOURISHMENT

KITCHEN

2K04

74.88 SF

BATHROOM

2K07A

52.03 SF

ISOLATION

2K09B

75.29 SF

BATHROOM

2K08A

47.03 SF

UNISEX

RESTROOM

2K35

164.66 SF

ELECTRICAL

2K11

222.19 SF

STORAGE

ROOM

2K10

497.58 SF

NURSING

UNIT 2K

CORRIDOR

C2-9

186.38 SF

PATIENT

ROOM

2K08

187.72 SF

PATIENT

ROOM

2K07

511.16 SF

CORRIDOR

C2-4

58.82 SF

BATHROOM

2K06A

132.21 SF

PATIENT

ROOM

2K06

123.05 SF

TEMPORARY

ROOM

2K38

130.68 SF

PATIENT

ROOM

2K09

56.82 SF

BATHROOM

2K09A

118.38 SF

FLEX OFFICE

2K36

26.94 SF

NURSING ED.

STORAGE

2K01A

243.07 SF

CLASSROOM

2K01

460.4 SF

PATIO

2K12

114.88 SF

NURSE

PRACTICIONER

2K37

107.51 SF

WORK ROOM

2K38A

355.41 SF

NURSING

UNIT 2K

CORRIDOR

C2-7

143.34 SF

FAMILY

WAITING

2G03

73.42 SF

SOILED LINEN

2K35

43.85 SF

HAC

2K39

179.43 SF

NURSING

INSTRUCTOR

2K02

39.14 SF

ELECTRICAL

XXXX

161.41 SF

PATIENT

ROOM

2J14

117.09 SF

ISOLATION

2J14A

168.81 SF

PATIENT

ROOM

2J15

286.6 SF

PATIENT

ROOM

2J18

178.43 SF

PATIENT

ROOM

2J16

178.87 SF

PATIENT

ROOM

2J17

81.85 SF

TRASH

COLLECTION

2G05

243.55 SF

MEN'S

LOCKERS

2G07

659.07 SF

CORRIDOR

C2-19

185.29 SF

PATIENT

ROOM

2J13

109.5 SF

PULMONARY

FELLOW

2J21

997.54 SF

MAINTANENCE

& REPAIR

2G09

53.18 SF

BATHROOM

2J20

252.7 SF

WOMEN'S

LOCKERS

2G08

181.78 SF

PATIENT

ROOM

2J12

609.23 SF

ICU NURSE

STATION

2J19

116.58 SF

WOMEN

2G03

95.8 SF

OFFICE

2J22

59.85 SF

HAC

2G10

859.35 SF

2G CORRIDOR

C2-10

182.02 SF

PATIENT

ROOM

2J11

102.01 SF

NURSE

MANAGER

2J23

124.81 SF

RETHERM

ROOM

2G11

502.45 SF

CORRIDOR

C2-1

91.19 SF

WORK ROOM

2J25

160.58 SF

STAIR 8

2S-8

112.99 SF

MEN

2G02

53.86 SF

HAC

2J22

384.93 SF

EQPT./STRETCHER

STORAGE

2J27

55.32 SF

BALCONY

2G46A

186.07 SF

VISITOR

LOUNGE

2G01

180.55 SF

PATIENT

ROOM

2J10

88.76 SF

CLEAN

UTILITY/LINEN

2J28A

271.17 SF

CORRIDOR

C2-18

158.97 SF

SPD

2J28

70.48 SF

OFFICE

2J21

281.81 SF

FAMILY AREA

2G46

1,104.04 SF

CORRIDOR

C2-3

367.21 SF

CORRIDOR

C2-20

285.07 SF

ELEVATOR

LOBBY,

PASSENGER

2G00

183.1 SF

PATIENT

ROOM

2J09

20.21 SF

ICE ROOM

2J30

77.05 SF

X-RAY

STORAGE

2J34

325.95 SF

ELEVATOR

LOBBY,

SERVICE

2G12

43.86 SF

STAFF ONLY

UNISEX

RESTROOM

2J32

508.81 SF

CORRIDOR

C2-2

112.91 SF

WORK ROOM

2J25

752.32 SF

LOUNGE

2G14E

50.38 SF

WATER ROOM

XXXX

271.66 SF

STAFF ONLY

MULTI-PURPOSE

ROOM

2J31

183.5 SF

PATIENT

ROOM

2J08

49.56 SF

BATHROOM

2G14B

45.05 SF

W.C.

2G44

45.75 SF

STORAGE

XXXX

125.27 SF

STAFF

LOUNGE

2G47A

313.93 SF

GAS LAB

2G43

131.56 SF

MEN'S

LOCKERS

2G45

140.18 SF

ELECTRICAL

2G13

141.83 SF

IT ROOM

2G20

40.61 SF

MEN

2G45A

1,151.63 SF

WAITING

AREA

2G23

94.64 SF

BEDROOM

2G14A

524.29 SF

ICU NURSE

STATION

2J00

336.87 SF

DIALYSIS

CLINIC

2J35

185.52 SF

PATIENT

ROOM

2J07

302.5 SF

ECHO LAB

2G40

61.34 SF

WOMEN

2G36B

179.35 SF

WOMEN'S

LOCKERS

2G36

99.73 SF

IT ROOM

2G37

140.97 SF

STAFF

LOUNGE

2G17

101.75 SF

RESPIRATORY

THERAPY

CHIEF

2G19

84.29 SF

CORRIDOR

C2-10B

160.43 SF

GAS LABS

2G42

75.14 SF

S.UTILITY

2G41

275.91 SF

ON CALL

2G14

179.92 SF

PATIENT

ROOM

2J06

838.59 SF

CORRIDOR

C2-13

870.8 SF

ICU 2J

CORRIDOR

C2-17

225.25 SF

CORRIDOR

C2-10A

262.38 SF

STORAGE

2G15

110.61 SF

BEDROOM

2G14C

105.06 SF

SOILED

UTILITY

2G18

378.05 SF

OXYGEN

STORAGEY

2G16

43.07 SF

GI RECOVERY

EQUIPMENT

2G24B

102.88 SF

PULMONOLOGIST

2G34

115.83 SF

PULM. PHY.

2G35

161.08 SF

STAIR 11

2S-11

48.21 SF

BATHROOM

2G14D

175.36 SF

PATIENT

ROOM

2J01

178.21 SF

PATIENT

ROOM

2J05

114.53 SF

ISOLATION

ROOM

2J05A

173.61 SF

PATIENT

ROOM

2J04

169.18 SF

PATIENT

ROOM

2J02

175.96 SF

PATIENT

ROOM

2J03

171.11 SF

CORRIDOR

C2-17

975.77 SF

GI RECOVERY

2G24

173.19 SF

CORRIDOR

C2-16

106.98 SF

PULMONOLOGIST

2G33

93.09 SF

BATHROOM

2G24A

97.62 SF

PULM. PHY.

2G28

175.71 SF

ECHO LAB

2G22

55.35 SF

PULMONARY

VESTIBULE

2G32A

169.4 SF

CHIEF

PULMONARY

2G32

111.53 SF

SEC. OFFICE

2G31

79.69 SF

PULM. OFFICE

2G29

106.39 SF

CARDIOLOGIST

2G30

OFFICE

2G24D

VASCULAR LAB

2G27

W.C.

2G38

W.C.

2G39

1' - 4" 9' - 2"

5'

0" 1'

5'

0" 1'

1' - 4" 1' - 4"

4' - 6 5/16"

Department Legend

CARDIOLOGY

COMMON

EMS

GI

ICU, NON SURGICAL

ICU, SURGICAL

IT

LLT&S

MSA

NURSING UNIT K

NUTRITION & FOOD SERVICE

ON CALL

PHARMACY

PULMANORY

SURGERY

P-7

P-8

P-9

P-10

S-8

S-9

S-10

S-11

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es = o ne fo ot 6"

6" on e a nd on e h alf in ch es

= o ne fo ot on e i nc h = on e f oo t

6" 6" thr ee qu art ers in ch on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

3/9/2017

1:40:11 PM

2ND FLOOR

BUILDING 204

JS TB

A101

Project Number

3/32" = 1'-0"1 Level 2

TEMPLE, TX

File details come from the government source that posted it. Updated .