36C25720Q0070-0001008.docx
DOCX document Posted
- Solicitation number
- 36C25720Q0070
About this file
This document is an amendment to a previous combined solicitation for a new contract opportunity to replace heat exchangers and hot water heaters at the Central Texas VA Medical Center in Temple, Texas. The Department of Veterans Affairs VISN17 Network Contracting Activity is seeking to replace blown tube bundles on multiple heat exchangers in various buildings, relocate and install new heat exchangers in one area, install a new heat exchanger in another location, and replace two hot water heaters converting them from pneumatic to electronic control. Offerors must provide all labor, equipment, materials, and supplies to complete the work within sixty calendar days of notice to proceed and ensure all equipment is tested and fully functional upon installation. The NAICS code listed is 238220 and recovery act funds are not involved.
36C25720Q0070 0001 36C25720Q0070 0001_1.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25720Q0070-0002004.pdf | ||
| 36C25720Q0070-0002003.docx | DOCX document | |
| 36C25720Q0070-0001009.pdf | ||
| 36C25720Q0070-0001010.pdf | ||
| 36C25720Q0070-001.pdf | ||
| 36C25720Q0070-002.pdf | ||
| 36C25720Q0070-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Amendment to a Previous Combined Solicitation
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field Contract Opportunity Amendment to a Previous Combined Solicitation J New - CTX Heat Exchanger/Hot Water Heater Replacement 78229 36C25720Q0070 01-07-2020 N 238220 Department of Veterans Affairs VISN17 Network Contracting Activity 7400 Merton Minter Blvd. (10N17/90C) San Antonio TX 78229 CTX Heat Exchanger/Hot Water Heater Replacement The VA requires the Heat Exchanger/ Hot Water Replacement for the Central Texas VA Medical Center located at 1901 Veterans Memorial Dr, Temple, TX 76504. This is a new requirement for Heater Exchanger/ Hot Water Replacement.
The vendor shall provide all labor, equipment, tools, materials and supplies required to remove, replace or repair the following listed below:
• Bldg. 163 Rm. BC150: replace blown tube bundle on heat exchanger.
• Bldg. 163 Rm. BA229: replace blown tube bundle on heat exchanger.
• Bldg. 163 Rm. 1D127: remove, relocate/re-pipe, install 2 new heat exchangers.
• Bldg. 163 Penthouse: replace 2 tube bundles on existing heat exchangers.
• Bldg. 163 Mezzanine: Install and pipe heat exchanger.
• Bldg. 202 Mechanical room: replace blown heat exchanger tube bundles.
• Bldg. 205 Mechanical room: replace 2 hot water heaters, converting them from pneumatic to electronic actuated system.
1. B. Description of Work:
1. • Replace tube bundles in Bldg. 163 rooms BC150 and BA229 with new. Replace existing heat exchanger in Bldg. 163 room 1D127 with new larger capacity heat exchanger specified by VA. Relocate with new piping to new location specified by VA.
1. • Replace existing tube bundles in Bldg. 163 Penthouse heat exchanges with exact specified replacement per manufactured specifications.
1. • Install existing heat exchanger in Bldg. 163 A5 Mezzanine. Install needed steam and condensate line and properly connect unit to existing steam system. Location determined by the VA.
1. • Replace tube bundles in Bldg. 202 mechanical with new.
1. • Replace existing pneumatic hot water heater in Bldg. 205 mechanical room with new electronic controlled steam generated hot water heater. Specified by VA.
1. • All insulation missing, damaged, removed or inadequate will be reinsulated by the contractor.
1. • All heat exchangers old or new will have a thermostatic air vent and vacuum breaker installed on heat exchangers.
1. • All specifications on items being replaced and installed will be FIELD VERIFIED and the specifications provided to the VA PRIOR to purchase.
1. • This contract is a TURN KEY project.
1. • All work shall be accomplished within sixty (60) calendar days from the date designated by the notice to proceed.
1. • All equipment will be tested and fully functional upon completion of installation.
See attached document: 36C25720Q0070 0001.
See attached document: Copy of Equipment Information.
File details come from the government source that posted it. Updated .