36C25623R0031 THIRD FLOOR C2 ALL LIGHT HUEN FAB-2 - S02.pdf
PDF 1 MB Posted
- Solicitation number
- 629-22-133
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
s s s s s s s s s
03 03 03 03 s s s s s s s s s
XX
N
N
N N N N NN
N N N N N N N
N
N
N
N
N
S S S S S S
9' - 6"
16' - 6"16' - 6"16' - 6"
9' - 0"
9' - 0"
9' - 0"
9' - 6"9' - 6"9' - 6"9' - 6"9' - 6"9' - 6"9' - 6"
9' - 0"
8' - 10" 7' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"9' - 2" 9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 6" 9' - 6" 9' - 6"9' - 6"9' - 6"
9' - 0" s
E
E
LV
LV
W1
01 701 7
FCD2a
FTG2c (EC) FTG2c FTG2cFTG2c FTG2c
FCD2a FCD2a
FCD2a
FCD2a
FTG13 (EC)
FTG2c
FTG3g (EC)
FTG2c
FCD2a
FCW3
FCW3
FCW3
FCW3FCW3
FCW3FCW3
FTP4d (CE) FTP4d (CE) FTP4d (CE) c
FTP4d (CE)
0ES515
(TYPICAL)
UP
DN
DN
UP
ELSL1442-1 ELSL1442-1 ELSL1442-1
ELSL1442-1
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
12h
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
DDK1 (EC)
c c a b a
E
L1432-7 b b
E
E b b
LVab a,b
L1432-7 a
L1432-7 a
L1432-7 a
L1432-7 a
R12323B-35
E
ECL1432-3 j,l j,l
E
ECL1432-3 m,n m,n
E
ECL1432-3 r,s r,s
E
ECL1432-3 t,u t,u
ELS1442-7 ELS1442-7
ELS1442-7 ELS1442-7 ELS1442-7 ELS1442-7 ELS1442-7 ELS1442-7 ELS1442-7 ELS1442-7
ELS1442-7ELS1442-7ELS1442-7ELS1442-7ELS1442-7ELS1442-7ELS1442-7L1432-10 i L1432-10 i
L1432-10
L1432-10
ECL1432-2
E
LVa E
E
ECL1432-2
ECL1432-2
E
ECL1432-2
E
ECL1432-2
E
ECL1432-2
E
ECL1432-2
E ECL1432-2a a,b LVab
ELSL1422-4
ELSL1432-2
b a,b a a b bb
01 H
01 H
01 K
01 K
M
M
01 9
6.3
6.3
8.2
8.2
LVjl LVmn LVrs
HE-1EP407
1EP401
1EP401
1EP401
1EP401
1EP401
1EP401
1EP401
1EP401
1EP401
1EP401
1EP401
h h h h h h h h h h h h h h h h h h h h h h h h h h h h
L1432-12 L1432-12
L1432-10 i iL1432-10 h h h h i i h h h i L1432-10L1432-10 i h hh h h h i L1432-10L1432-10 i i L1432-10L1432-10 ii L1432-10L1432-10 i
LVtu
FTP5a
FTP5a
E
ECL1432-2
EC
3C154
PATIENT
3C153
PATIENT
3C156
PATIENT
3C158
PATIENT
3C160
PATIENT
3C162
PATIENT
3C164
PATIENT
3C163
PATIENT
3C161
PATIENT
3C159
PATIENT
3C157PATIENT
3C155 PATIENT POS
3C165
CC
3C152F
SUB-STATION
3C133A
SUB-STATION
3C133C
SUB-STATION
3C133E
T
3C150A
T
3C153A
T
3C156A
T
3C158A T
3C162A
T
3C160A
ISO T
3C165A
T
3C164A
T
3C159A
T
3C161A
T
3C157A
T
3C155A
ANTE POS
3C165B
T
3C167
MED
3C152E
CLEAN
3C152C
AISLE
3C-C02A
SUPPLY
3C133B
CORR
3C-C02
STAIR
STC-3
SUPPLY
3C133D
PATIENT
3C162
CR
FE
C
STP
FEC
RESPITE
3C166
FTG6a (EC)FTG6a (EC)FTG6a (EC)FTG6a (EC)FTG6a (EC)FTG6a (EC)FTG6a (EC)FTG6a (EC)
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FCD2aFCD2aFCD2aFCD2a
FTG2c (ELS)
FTG2c (ELS)
FTG2c (ELS)
FTG2c (ELS)
FCD2a
FTG6a (EC)
FTG6a (EC)
FCD2a
FTG2c
FTG2c
FCD2a
FTG6a (EC)
FTG6a (EC)
FCD2a
FTG2c
FTG2c
FCD2a
FTG6a (EC)
FTG6a (EC)
FCD2a
FTG2c
FTG2c
FCD2a
FTG6a (EC)
FCD2a
FTG2c
FTG2c
FTG6a (EC)
FCD2a
FTG6a (EC)
FCD2a
FTG2c
FTG2c
FTG6a (EC)
FCD2a
FCD2a
FTG2c
FTG2c
FCD2a FCD2a
FCD2a
FTG2c
FTG2c
FTG6a (EC) FTG6a (EC)
FCD2a
FTG2c (EC)
FTG2c (EC)
FCD2b (EC)
FTG2g (EC)
FCD2b (EC)
FTG2g (EC)
FCD2b (EC)
FTG2g (EC)
FCD2b (EC)
FTG2g (EC)
FCD2b (EC)
FTG2g (EC)
FCD2b (EC)
FTG2g (EC)
FCW3
FCW3 FCW3
FCW3
FCW3
FCW3
FCW3FCW3
FCW3
FCW3FCW3FCW3
FCW3
FCW3
FCW3
FCW3FCW3FCW3
FCW3FCW3
FCW3
FCD2a FCD2a FCD2a FCD2a
FTG3g (EC)
FTG3g (EC)
FTG3g (EC)
FTG3g (EC)
FTG3g (EC)
FTG2c (ELS) FTG2c (ELS)FTG2c FTG2cFTG2c (ELS) FTG2c (ELS)FTG2c FTG2cFTG2c (ELS)FTG2c (ELS)FTG2c FTG2cFTG2c (ELS) FTG2c (ELS) FTG2c (ELS)
FTG2c FTG2c (ELS)FTG2c FTG2c (ELS)FTG2c (ELS) FTG2c (ELS)FTG2c (ELS) FTG2c (ELS)FTG2c (ELS)FTG2c (ELS)
FCD2b (EC)
FTG2g (EC)
FCW3FCW3
FCD2b (EC)
FTG2g (EC)
FCW3FCW3
FCD2b (EC)
FTG2g (EC)
FCW3FCW3
FCD2b (EC)
FTG2g (EC)
FCW3FCW3
FCD2b (EC)
FTG2g (EC)
FCW3
FCD2aFCD2aFCD2aFCD2a
FCD2a
L1432-12
L1432-12L1432-12L1432-12
L1432-12L1432-12L1432-12L1432-12
L1432-12L1432-12L1432-12
L1432-12L1432-12L1432-12L1432-12
L1432-12L1432-12L1432-12
L1432-12L1432-12L1432-12
L1432-12L1432-12
L1432-12L1432-12
L1432-12
L1432-12
L1432-12
L1432-12 L1432-12L1432-12L1432-12L1432-12L1432-12L1432-12L1432-12L1432-12L1432-12L1432-12L1432-12
E
E
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
L1432-7
L1432-7
L1432-7
L1432-7
R12323B-35
ECL1432-6ECL1432-6
E E
E
E
E
E E
FTU1e
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
ECL1432-6
L1432-7
L1432-7
L1432-7
R12323B-35
ECL1432-6ECL1432-6
E E
E
E
E
E E
FTU1e
L1432-5
ECL1432-4
ECL1432-4
ECL1432-4
ECL1432-4
ECL1432-4
L1432-5
L1432-5
L1432-5
R12323B-35
ECL1432-4ECL1432-4
E E
E
E
E
E E
FTU1e
L1432-5
ECL1432-4
ECL1432-4
ECL1432-4
ECL1432-4
ECL1432-4
L1432-5
L1432-5
L1432-5
R12323B-35
ECL1432-4ECL1432-4
E
E
E
E E
FTU1e
E E
L1432-5
ECL1432-4
ECL1432-4
ECL1432-4
ECL1432-4
L1432-5
L1432-5
L1432-5
R12323B-35
ECL1432-4ECL1432-4
E
E
E
E E
E E
FTU1e FTU1e
R12323B-35 R12323B-35
FTU1e
FTR2a (EC)
ECL1432-11
ECL1432-11
ECL1432-11
ECL1432-11
ECL1432-11
ECL1432-11
E
E
E
E E
E
E E
E
E
E
ECL1432-10
ECL1432-10
ECL1432-10
L1432-11
L1432-11
L1432-11
ECL1432-10
ECL1432-10
ECL1432-10
L1432-11
ECL1432-10
E E
L1432-11
FTU1eFTU1eFTU1eFTU1e R12323A-39 R12323A-39 R12323A-39 R12323A-39
FTU1e R12323A-39
FTU1e R12323A-39
L1432-11
ECL1432-10
ECL1432-10
ECL1432-10
ECL1432-10
ECL1432-10
ECL1432-10
ECL1432-10
ECL1432-10
ECL1432-10
E E
E E
E
E
E
L1432-11 L1432-11
L1432-11
L1432-11
L1432-11
E E
E
E
E
ECL1432-10
ECL1432-10
ECL1432-10
L1432-11
L1432-11
L1432-11
ECL1432-10
ECL1432-10
ECL1432-10
L1432-11
ECL1432-10
E E
E E
E
E
E
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
L1432-9
L1432-9
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
ECL1432-8
E E
E E
E
E
E
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
L1432-9
L1432-9
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
ECL1432-8
E E
E E
E
E
E
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
L1432-9
L1432-9
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
ECL1432-8
E E
E E
E
E
E
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
L1432-9
L1432-9
ECL1432-8
ECL1432-8
ECL1432-8
L1432-9
ECL1432-8
E E
FTU1e R12323A-39
FTU1e R12323A-39
FTU1e
L1432-16
L1432-16
L1432-16
01 L
01 L
01 J
01 J
01 801 8
9.2
9.2
9.6
9.6
M.1
M.1
4'N
4'N
4'S 01 8
4'S 01 8
12'W M
12'W M
FTR2a (EC)
FTR2a (EC)
ECL1432-2
E
01 9 01 9
01 601 6
01 701 7
9.6
9.6
9.2
9.2
8.2
8.2
5.3
5.3
GENERAL NOTES:
1. REFER TO LEGEND AND GENERAL NOTES ON DRAWING 0ES001.
2. THE ELECTRICAL CONTRACTOR SHALL COORDINATE
MOUNTING OF LIGHTING FIXTURES WITH ARCHITECTURAL
REFLECTED CEILING PLAN AND ELEVATIONS PRIOR TO
INSTALLATION.
3. REFER TO LIGHTING FIXTURE SCHEDULE ON DRAWINGS.
4. EXIT SIGNS SHALL BE CONNECTED TO UNSWITCHED EMERGENCY
CIRCUIT.
5. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL
LIGHTING IN MECHANICAL SPACES AND LOCATE LIGHTING
AROUND DUCTWORK AND PIPING TO ALLOW PROPER ILLUMINATION
AND AVOID CONFLICTS WITH OTHER TRADES.
6. REFER TO THE RESPECTIVE POWER PLAN FOR
PANEL LOCATIONS.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR EXACT LOCATION AND QUANTITY OF FIXTURES.
UNLESS OTHERWISE NOTED, ALL OCCUPANCY SENSORS SHALL BE FIELD SET FOR
VACANCY MODE/MANUAL "ON" VIA LOW VOLTAGE WALL SWITCH. REFER TO
REFERENCE DETAIL FOR SPECIFIC SEQUENCE OF OPERATION.
LIGHTING CONTROL GENERAL NOTES:
1.
OCCUPANCY SENSOR NUMBER DENOTES DETAIL REFERENCE ON DRAWING
0ES514, E.G. '02' DENOTES DETAIL 2/0ES514. REFER TO ASSOCIATED DETAIL FOR
USE,WIRING, AND CONTROL INTENT.
2.
LOWER CASE LETTER INDICATES ASSOCIATED ROOM CONTROL/SWITCH LEGS.
"Rx" NUMBERS INDICATE ASSOCIATED RELAY CONTROL. REFER TO LIGHTING
CONTROL PANEL SCHEDULES FOR RELAY REQUIREMENTS.
3.
RQUIRED POWER PACKS, ROOM CONTROLLERS, AND LOW VOLTAGE WIRING AND
INTERCONNECTIONS NOT SHOWN ON PLANS. REFER TO DETAILS, DRAWING
0ES514 AND 0ES515 FOR RQUIREMENTS.
4.
REFER TO LIGHTING CONTROL RISER DIAGRAM AND SCHEDULES FOR LIGHTING
CONTROL PANEL AND RELAY CHANNEL GROUPING REQUIREMENTS.
5.
ALL TIME SCHEDULED EVENTS SHALL BE INITIATED BY THE BAS VIA LIGHTING
CONTROL PANEL BACNET INTERFACE. LIGHTING CONTROL RELAYS SHALL DEFAULT
TO THE 'ON' POSITION IN THE EVENT OF NETWORK TROUBLE OR LOSS OF
CONNECTION TO THE BAS.
6.
WHERE SHOWN ON PLANS, PUBLIC AREAS SPACES WITH SUFFICIENT GLAZING
SHALL INCLUDE PHOTCELL OVERRIDE TO SHUT OFF INDIVIDUAL LIGHTING ZONES
WHEN DAYLIGHT PENETRATION IS SUFFICIENT. REFER TO LIGHTING CONTROL
PANEL SCHEDULES AND RISER DIAGRAMS FOR REQUIREMENTS.
7.
CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED MODULES, INTERFACES,
AND CONTROL INTERCONNECTIONS AS REQUIRED BY MANUFACTURER TO MEET
SPACIFIED CONTROL INTENT.
8.
PROVIDE UL924 BYPASS RELAY FOR EACH SWITCHED LIFE SAFETY ZONE. REFER
TO DETAILS ON DWG 7ES507 AND 7ES508.
9.
UNDER NO CIRCUMSTANCES SHALL LINE VOLTAGE LIFE SAFETY WIRING BE
LOCATED WITHIN THE SAME JUCNTION BOX WITH OTHER SYSTEMS WIRING WITH
THE EXCEPTION OF WITHIN UL924 DEVICES.
10.
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
GENERAL NOTES:
Drawn By: Job No.:
Date:Scale:
Drawing No.:
Title:
As indicated
HE-1EL103-C2
BLDG 1 THIRD FLOOR
LIGHTING PLAN - AREA C2
7151-1
NEW ORLEANS, LOUISIANA
Department of Veterans Affairs
SLVHCS Replacement Medical Center Project
03/18/11
DRC
DRAWING FOR REFERENCE ONLY.REVIEW CONTRACT AND SIGNED OFF COORDINATION DRAWINGS FOR INSTALLATION METHOD.
1/8" = 1'-0"
LEVEL 03 - Lighting - Area C2
Rev. No. Description Date
1 Issued For Level 3 Signoff 08-26-2013
2 Issued For Construction Level 3 09-03-2013
3 Re-Issued Per Bull#15a/15b & RFI #2078 10-31-2013
4 Re-Issued for Signoff Level 1,2,3 for Bull#15a/15b/15c
11-25-2013
5 Re-Issued for Construction Post Coordination
11-25-2013
6 AS BUILT - JJ Date 29