36C25618B0674-0003003.pdf
PDF 5 MB Posted
- Attached to
- Project No. 586-16-102 "Upgrade Chiller Plant"
- Solicitation number
- 36C25618B0674
About this file
36C25618B0674 0003 A0003 Attch 2 Contract Dwgs.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25618C0128-000.docx | DOCX document | |
| 36C25618B0674-0006000.docx | DOCX document | |
| 36C25618B0674-0005000.docx | DOCX document | |
| 36C25618B0674-0005001.pdf | ||
| 36C25618B0674-0004000.docx | DOCX document | |
| 36C25618B0674-0004001.pdf | ||
| 36C25618B0674-0003009.docx | DOCX document | |
| 36C25618B0674-0003001.docx | DOCX document | |
| 36C25618B0674-0003007.pdf | ||
| 36C25618B0674-0003000.docx | DOCX document | |
| 36C25618B0674-0003006.pdf | ||
| 36C25618B0674-0003005.pdf | ||
| 36C25618B0674-0003002.pdf | ||
| 36C25618B0674-0003008.pdf | ||
| 36C25618B0674-0003004.jpg | JPG image | |
| 36C25618B0674-0002000.docx | DOCX document | |
| 36C25618B0674-0001000.docx | DOCX document | |
| 36C25618B0674-0001002.pdf | ||
| 36C25618B0674-0001001.pdf | ||
| 36C25618B0674-001.docx | DOCX document | |
| 36C25618B0674-005.pdf | ||
| 36C25618B0674-002.pdf | ||
| 36C25618B0674-003.pdf | ||
| 36C25618B0674-006.pdf | ||
| 36C25618B0674-004.pdf | ||
| 36C25618B0674-000.docx | DOCX document |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
C a n n o n
D e s ig n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
Consultants:
BOSTON NEW YORK BALTIMORE WASHINGTON DC BUFFALO TORONTO MONTREAL PITTSBURGH
CHICAGO ST. LOUIS VANCOUVER SAN FRANCISCO LOS ANGELES PHOENIX MUMBAI ABU DHABI
/1
/2
:5
:1
P
M
Chiller Plant Upgrade Jackson, MS VA Medical Center
CannonDesign Project Number: 003640.62 Project Status: 100% SUBMISSION Issue Date: SEPTEMBER 13, 2017
U.S. Department of Veteran Affairs
VA PROJECT NO: 586-16-102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102DRAWING INDEX
G0001 Checker Author
DRAWING INDEX
SHEET NUMBER SHEET NAME R
E
V
IS
IO
N
GENERAL
G0000 COVER SHEET
G0001 DRAWING INDEX
ARCHITECTURAL
A0001 SYMBOLS & ABBREVIATIONS
A0101 FLOOR PLAN AND DETAILS
10 DEMOLITION
D0601 HVAC DEMOLITION PLAN
ED0101 ELECTRICAL DEMOLITION PLAN
70 MECHANICAL
M0001 LEGENDS, SYMBOLS, & GENERAL NOTES
M0101 HVAC EQUIPMENT PLAN AND SCHEDULES
M0201 HVAC DUCTWORK AND PIPING PLAN - GROUND FLOOR
M0202 HVAC DUCTWORK AND PIPING PLAN - ROOF
M0301 ENLARGED PLANS AND SECTIONS
M0601 CHILLED WATER SYSTEM FLOW AND CONTROL DIAGRAM
M0603 CHILLED WATER SYSTEM SEQUENCE OF OPERATIONS
M0701 DETAILS AND CONTROL DIAGRAMS
80 ELECTRICAL
E0001 NOTES, LEGENDS, SYMBOLS AND ABBREVIATIONS
E0050 ELECTRICAL SITE PLAN
EL0101 LIGHTING PLAN
EP0101 POWER PLAN
EP0201 ONE LINE DIAGRAMS
EP0301 SCHEDULES
EP0302 DETAILS
FA0101 FIRE ALARM PLAN
C
D
PARTITION PARTITION TYPE
INTERIOR DOOR
ASSEMBLY
SUFFIX ADDED IF
MULTIPLE DOORS
SERVE SAME ROOM
EXTERIOR
GLAZED
OPENINGS
LOUVER
ROOM NAME
AND NUMBER 1125
ROOM NAME
ROOM NUMBER
SHEET NOTE
DEMOLITION
CONSTRUCTION
KEYNOTE
SPECIFICATION
SECTION
SPECIFIED ITEM
1125A
OFFICE
EXTERIOR DOOR
ASSEMBLY
BORROWED
LIGHT
ROOM NUMBER
EQUIPMENT
EQUIPMENT IDENTIFIER
ROOM NUMBER
SERVED BY DOOR
NUMBERED
SEQUENTIALLY
DENOTES
EXTERIOR DOOR
SUFFIX ADDED IF
MULTIPLE OPENINGS
SERVE SAME ROOM
NUMBERED
SEQUENTIALLY
DENOTES
EXTERIOR OPENING
042000 - UNIT MASONRY
ROOF ASSEMBLY TAG
SOFFIT ASSEMBLY TAG
EXTERIOR WALL
ASSEMBLY TAG
WALL SECTION
DETAIL/ SECTION
NUMBER
SHEET NUMBER
BUILDING SECTION
EXTERIOR ELEVATION
SHEET NUMBER
ELEVATION NUMBER
INTERIOR ELEVATION
ELEVATION NUMBER
SHEET NUMBER
LARGE SCALE BLOWUP
OF PLAN OR DETAIL
PLAN OR DETAIL
NUMBER
SHEET NUMBER
LEVEL REFERENCE
LEVEL DESCRIPTION
LEVEL ELEVATION
NEW
STRUCTURAL GRID
GRID REFERENCE
GRID LINE
EXISTING
STRUCTURAL GRID
EXISTING GRID
REFERENCE
EXISTING GRID LINE
MATCH LINE
SHEET NUMBER
SHEET NUMBER
MATCH LINE
REVISION
REVISION NUMBER
(SHEET SPECIFIC)
CLOUDED AREA
OF REVISION
NORTH ARROW
SIMILAR INDICATION
DETAIL SECTION
R
DETAIL / SECTION
NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
SPOT ELEVATION
REFERENCE TYPE,
AS NEEDED:
TYP OR SIM
REFERENCE SYMBOLS (ALL DISCIPLINES)__________ REFERENCE SYMBOLS (ARCHITECTURAL)_______
CEILING HEIGHT
HEIGHT OF
CEILING ABOVE
FINISHED FLOOR
LAY IN PANEL
SURFACE OR
RECESSED
LUMINAIRE
SPRINKLER HEAD
AIR DEVICE -
RETURN
OCCUPANCY SENSOR
SMOKE DETECTOR
HEAT DETECTOR
SPEAKER
FIRE ALARM SPEAKER F
AIR DEVICE -
SUPPLY
AIR DEVICE -
EXHAUST
DAYLIGHT SENSOR
RADIANT PANEL
ACCESS DOOR
PENDANT HUNG
LUMINAIRE
AIR DEVICE -
LINEAR SUPPLY
MOTION / SECURITY
DETECTOR
CAMERA
CLOCK
M
P
H
S
S
REFLECTED CEILING PLAN SYMBOLS)_________________________________
AC AIR CONDITIONING
ACC ACCESSIBLE
ACM ASBESTOS CONTAINING MATERIAL
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AGF ARCHITECTURAL GLASS FLOORING
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ALT ALTERNATE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
ASN ABRASIVE STAIR NOSING
ATC ACOUSTICAL TILE CEILING
AUTO AUTOMATIC
AWP ACOUSTICAL WALL PANEL
BLDG BUILDING
BLKG BLOCKING
BRG BEARING
BSMT BASEMENT
C COURSE
CB SELF-COVE BASE
CFCI CONTRACTOR FURNISHED - CONTRACTOR INSTALLED
CF CONDUCTIVE FLOORING
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR(ANCE)
CLRM CLASSROOM
CMT CERAMIC MOSAIC TILE
CMTB CERAMIC MOSAIC TILE BASE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CONTR CONTRACT(OR)
CORR CORRIDOR
CPT CARPET(ING)
CR CRASH RAIL
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CUH CABINET UNIT HEATER
CW CASEWORK
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
EA EACH
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
EL ELEVATION
ELEV ELEVATOR
EM ENTRANCE MATS
EMB ELECTRONIC MARKER BOARD
EMER EMERGENCY
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
ER EPOXY RESIN
EST ESTIMATE(D)
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXPD EXPOSED
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FG FOOT GRILLE
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FLR FLOOR
FT FOOT/FEET
FTG FOOTING
FURN FURNISH(ED) / FURNISHINGS
FWP FABRIC WRAPPED PANEL
GA GAUGE / GAGE
GALV GALVANIZED
GFRC GLASS FIBER REINF CONCRETE
GFRG GLASS FIBER REINF GYPSUM
GL GLASS
GLMT GLASS MOSAIC TILE
GLMU GLASS MASONRY UNIT
GLT GLASS TILE
GST GLASS STAIR TREAD
GWB GYPSUM WALL BOARD
GWB P GYPSUM WALL BOARD PAINTED
GWP EP GYPSUM WALL BOARD EPOXY PAINTED
GYP GYPSUM
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH POINT
HPC HIGH PERFORMANCE COATING
HPL HIGH PRESSURE DECORATIVE LAMINATE
HR HANDRAIL
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HVAC HEATING-VENTILATING-AIR CONDITIONING
HWB HEAT WELDING BEAD
ID INSIDE DIAMETER
INST INSTALL(ED)
INSUL INSULATION / INSULATED
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE(D)
LAV LAVATORY
LGT LENGTH
LH LEFT HAND
LIN LINOLEUM
LP LOW POINT
LT LIGHT
LTWT LIGHTWEIGHT
LVT LUXURY VINYL TILE
MACH MACHINE
MARB MARBLE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MCM METAL COMPOSITE MATERIAL
MECH MECHANICAL
MES METAL EDGE STRIP
MEZZ MEZZANINE
MFR MANUFACTURER / MANUFACTURED
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MPC METAL PANEL CEILING
MSS METAL SUSPENSION SYSTEM
MTL METAL
MW MILLWORK
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NSMF NON-STRUCTURAL METAL FRAMING
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED - CONTRACTOR INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED - OWNER INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCONC POLISHED CONCRETE
PERF PERFORATE(D)
PL PLATE
PLP PLASTIC PANEL
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRT POLY RESIN TILE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PLSHD POLISHED
PMT PORCELAIN MOSAIC TILE
PNT PAINT(ED)
PT PORCELAIN TILE
PTB PORCELAIN TILE BASE
QT QUARRY TILE
QTB QUARRY TILE BASE
QTY QUANTITY
R RISER
RAD RADIUS
RAF RESILIENT ATHLETIC FLOORING
RBF RUBBER FLOORING
RBRT RUBBER TILE
RCP REFLECTED CLG PLAN
RD ROOF DRAIN
REF REFER TO / REFERENCE TO
REFG REFRIGERATOR
REINF REINFORCED / REINFORCING
REQD REQUIRED
RES RESILIENT
RESB RESILIENT BASE
REV REVISE / REVISION
RF RESINOUS FLOORING
RFG ROOFING
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RSN RESILIENT STAIR NOSING
RST RESILIENT STAIR TREAD
RT RESILIENT TILE
RTU ROOF TOP UNIT
RV RIGID VINYL
S SEALED
SDF STATIC DISSIPATIVE FLOORING
SECT SECTION
SGT STRUCTURAL GLAZED TILE
SHR SHOWER
SHT SHEET
SIM SIMILAR
SM SPECIALIZED METAL
SOG SLAB-ON-GRADE
SP SAFETY PAD
SPEC SPECIFY / SPECIFICATION
SQ SQUARE
SS SOLID SURFACE / SURFACING
SST STAINLESS STEEL
ST STONE
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SVT SOLID VINYL TILE
SWC SPECIAL WALL COATING
SWP SHEET WALL PROTECTION
T TREAD
TB TACK BOARD
TBD TO BE DETERMINED
TEMP TEMPORARY
TER TERRAZZO
TERB TERRAZZO BASE
TEXT TEXTURE
THK THICK(NESS)
TLT TOILET
TOS TOP OF STEEL
TOW TOP OF WALL
TP TANGENT POINT
TS TACKABLE SURFACE
TRSLT TRANSLUCENT
TYP TYPICAL
T&G TONGUE & GROOVE
UC UNDERCOUNTER
UPH UPHOLSTERY
UNO UNLESS NOTED OTHERWISE
VAC VACUUM
VCT VINYL COMPOSITION TILE
VEST VESTIBULE
VET VINYL ENHANCED TILE
VIF VERIFY IN FIELD
VNL VINYL
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
WAF WOOD ATHLETIC FLOORING
WC WATER CLOSET
WCV WALL COVERING
WD WOOD
WDWTR WINDOW TREATMENT
WP WORK POINT
WPC WOOD PANEL CEILING
WT WEIGHT
GENERAL NOTES_____________________________________________
1. ENCLOSE ALL EXPOSED DUCTS, PIPES, CONDUITS, ETC. IN FINISHED SPACE WITH CONSTRUCTION
AND FINISH TO MATCH ADJACENT CONSTRUCTION UNO.
2. PROVIDE ACCESS DOORS OF APPROPRIATE SIZE, TYPE AND FIRE RATING FOR ALL CONCEALED ITEMS THAT REQUIRE ADJUSTMENT, MAINTENANCE, MONITORING, ETC. COORDINATE LOCATIONS
WITH ARCHITECT.
3. DO NOT DETERMINE DIMENSIONS AND SIZE OF THE GRAPHIC REPRESENTATIONS SHOWN ON THE DRAWINGS BY USING MEASURING DEVICES (DO NOT "SCALE"). RELY ON THE NUMERIC DIMENSIONS
SHOWN ON THE DRAWINGS FOR MEASUREMENT.
4. DIMENSIONS ARE TAKEN FROM CENTERLINE OF STRUCTURE, FACE OF CONCRETE OR FINISHED
FACE OF PARTITIONS UNO. SEE PARTITION TYPES SHEETS (A1000 SERIES) FOR PARTITION
THICKNESS AND MATERIALS.
5. CENTER ITEMS IN CEILING PANELS UNO.
6. REFER TO FINISH LEGEND FOR FINISH PLAN SYMBOLS.
ABBREVIATIONS______________________________________________
A101
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW CONSTRUCTION
PLAN SYMBOLS_____________________________________________________
INTERIOR ELEVATION KEY TO MATERIAL
SIM
50S
IM
50 S
IM
A0402
SIM
A1
E101
E45
1125A
L10
RA-1
SA-1
WA-1
A0401
SIM
A0401
SIM
A0401
SIM
1/A101
SIM
LEVEL 02
118'-6"
9 '- 0"
TYPE MARK
STC TAG STC-45
N
1 / A101
1 / A101
SIM
A0401
SIM
DESCRIPTION
EQ-1
EQUIPMENT DESCRIPTION
ADA
HANDICAPPED
CLEARANCES
FINISH TAG
P-3WALL FINISH TAG
C
CEILNG MICROPHONE M
WIRELESS AP
UNDER CABINET
LUMINAIRE
A/V PROJECTOR
PROJECTOR SCREEN
F
B
W
C
LCENTERLINE
INDICATES AREAS NOT IN CONTRACT
EXIT LUMINAIRE
SPRINKLER HEAD
TRACK LIGHT
NURSE CALL DOME
LIGHT
IV / CURTAIN TRACK
N
WALL WASH
LUMINAIRE
STRIP LUMINAIRE
COVE LUMINAIRE
SURGICAL LIGHT/
EQUIPMENT BOOM
PENDANT
WALL MOUNT STRIP
WALL MOUNT STRIP
EARTH
GRAVEL OR
POROUS FILL
CONCRETE
MASONRY UNIT
BRICK STONE
CONCRETE OR
PRECAST
RIGID INSULATION
PLASTER AND
GYPSUM BOARD
FINISHED WOOD
WOOD BLOCKING
OR SHIMPLYWOOD
STEEL OR IRONALUMINUM
SPRAY INSULATION
CORE MATERIAL
SPRAY
FIREPROOFING
ACOUSTICAL
CEILING
WOOD FRAMING
FIBERGLASS/
SOLID SURFACE
MATERIAL
COMPRESSIBLE
FILLER
TERRAZZO
FIBROUS BLANKET
INSULATION
(GLASS FIBER AND
MINERAL WOOL)
HORIZONTAL VERTICAL
FIBROUS BOARD
INSULATION
(GLASS FIBER AND
MINERAL WOOL)
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102SYMBOLS & ABBREVIATIONS
A0001 Checker Author
MATERIALS
A0101
6N03
N
X01
X
1. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO
PROPOSE A PHASING PLAN TO MEET THE REQUIREMENTS OF
THE CONSTRUCTION CONTRACT.
2. SEAL OFF EXISTING DOOR TO HOSPITAL AND COMMENCE ALL
WORK FROM EXTERIOR ACCESS.
3. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES
APPROPRIATELY AS SOON AS DETECTED.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
5. EXTERIOR SPACE ON-SITE WILL BE PROVIDED FOR
STORAGE OF CONSTRUCTION RELATED MATERIALS
AND EQUIPMENT.
SPRAY-FOAM INSULATION, 1-1/2" NOM.
4" RESILIENT BASE, TYP.
EXISTING EXTERIOR WALL ASSEMBLY
6 1/2"
5/8" GWB ABOVE 8'
MOVEMENT ASSEMBLY AT ROOF DECK
COPE AND SEAL GWB AT ROOF DECK
RE: 3/A0101 FOR HEAD DETAIL AT
STEEL ROOF JOISTS
5/8" IMPACT-RESISTANT GWB BELOW 8'
4" METAL STUD FRAMING
6"
M
IN1/4
M
IN1/4
/8
5/8" GWB, ATTACH TO VERTICAL STUDS ONLY
DEFLECTION TRACK
PROVIDE 1/4" GAP WITH FIRE SEALANT ALL
INTERSECTIONS OF GWB WITH STEEL JOIST
4" METAL FRAMING
5/8" GWB, ATTACH TO ANGLE ONLY
1-1/2" METAL FRAMING ANGLE, SECURE TO STRAPS
2"W 20GA STEEL STRAPS AT 12" O.C.
MINERAL WOOL INSULATION
FOAM INSULATION
EXISTING CMU EXTERIOR WALL
STEEL JOIST
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102FLOOR PLAN AND DETAILS
A0101 Checker Author
1/8" = 1'-0"
FIRST FLOOR
KEYED NOTES:
NUMBER DESCRIPTION
1 DEMOLISH CMU WALL ENTIRELY, INCLUDING OH AND MAN DOORS.
2 ALTERNATE: NEW INSULATION & INTERIOR COVER PARTITION AT
EXTERIOR CMU WALLS - RE: 2/A0101
3 ALTERNATE: RETURN GWB BACK TO DOOR FRAME AT EXISTING
DOORS, TYP.
4 ALTERNATE: SPACE TO RECEIVE NEW FINISHES, RE: GENERAL NOTES
5 INSTALL BLANK-OFF PANEL ON INTERIOR FACE OF EXISTING LOUVER
FOR PORTIONS UNUSED (RE: MECH DWGS). FABRICATE OF 1 INCH
THICK URETHANE INSUL CORE W/ .032 IN THICK ALUM FACE SHEET EA
SIDE & .080 IN EXTRUDED ALUM FRAME
6 DELETE EXISTING DOOR AND FRAME AND INSTALL NEW DOOR AND
FRAME IN EXISTING OPENING.
CONSTRUCTION GENERAL NOTES
GENERAL NOTES
1. IN SPACES INDICATED AS RECEIVING NEW FINISHES ALL
INTERIOR WALL SURFACES, ROOF JOISTS, AND ROOF
DECK WILL BE CLEANED, PRIMED, AND PAINTED.
2. IN SPACES INDICATED AS RECEIVING NEW FINISHES,
EXISTING CONCRETE FLOORS TO BE CLEANED AND
PREPPED AND INSTALL EPOXY FLOOR COATING.
3. IN SPACES INDICATED AS RECEIVING NEW FINISHES,
INSTALL NEW 4" HIGH RUBBER BASE.
1" = 1'-0"
WALL SECTION
3" = 1'-0"
PARTITION HEAD DETAILS
DOOR SCHEDULE
OPENING
NUMBER
DOOR FRAME
SCHEDULE
FIRE RATING COMMENTSMATERIAL
MATERIAL &
TYPE
N03 HM HM-00 45 MIN REPLACE EXISTING DOOR AND FRAME IN GWB OPENING.
PROVIDE NEW MORTISE LEVERSET WITH STORAGE
FUNCTION AND DEADBOLT
N04 HM HM-00 45 MIN REPLACE EXISTING DOOR AND FRAME IN GWB OPENING.
PROVIDE NEW MORTISE LEVERSET WITH STORAGE
FUNCTION AND DEADBOLT
X01 HM HM-00 - REPLACE EXISTING DOOR AND FRAME IN MASONRY
OPENING. GROUT FRAME SOLID. PROVIDE NEW MORTISE
LEVERSET WITH STORAGE FUNCTION AND DEADBOLT,
WEATHERSEALS AND THRESHOLD
X02 HM HM-00 - REPLACE EXISTING DOOR AND FRAME IN MASONRY
OPENING. GROUT FRAME SOLID. PROVIDE NEW MORTISE
LEVERSET WITH STORAGE FUNCTION AND DEADBOLT,
WEATHERSEALS AND THRESHOLD
1. THE CHILLED WATER PLANT SHALL REMAIN OPERATIONAL DURING DEMOLITION AND CONSTRUCTION.
2. PROVIDE HOT TAP OF TEMPORARY CHILLER CONNECTION LOCATIONS DURING OPERATION OF THE EXISTING CHILLED WATER EQUIPMENT PRIOR TO ANY
DEMOLITION WORK TO ENSURE CONTINUOUS OPERATION OF THE CHILLED WATER SYSTEM. COORDINATE HOT TAP INSTALLATION WITH THE OWNER'S
OPERATIONAL REQUIREMENTS. TERMINATE WITH ISOLATION VALVES.
3. COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, SAFETY RULES AND REGULATIONS, OSHA STANDARDS, VA DESIGN AND CONSTRUCTION STANDARDS, AND
OTHER GOVERNING BODIES HAVING JURISDICTION.
4. PROTECT DUCTWORK, PIPING, EQUIPMENT, ETC. REMAINING IN PLACE FOR REUSE. REPAIR OR REPLACE EQUIPMENT AND SYSTEMS TO BE REUSED WHICH ARE INADVERTENTLY DAMAGED DURING THE DEMOLITION PROCESS AT NO ADDITIONAL COST TO THE OWNER.
5. DISPOSITION OF THE MATERIAL ASSOCIATED WITH THE DEMOLITION PACKAGE WILL BE APPROVED IN WRITING BY THE OWNER. DO NOT REMOVE DEMOLISHED
MATERIALS FROM THE WORK SITE WITHOUT PRIOR APPROVAL OF OWNER.
6. PROVIDE AND INSTALL CLOSURE DEVICES FOR REMAINING SYSTEMS AND EQUIPMENT. VERIFY THAT THE CLOSURE DEVICES HAVE BEEN INSTALLED PRIOR TO RE-ENERGIZING SYSTEMS. COMPLY WITH OWNER AND SITE LOCK-OUT/TAG-OUT PROCEDURES WHERE APPLICABLE.
7. DO NOT REUSE REMOVED PIPING, DUCTWORK, VALVES, ETC., UNLESS SPECIFICALLY INDICATED OTHERWISE.
8. PATCH AND REPAIR ALL FINISHES AND PENETRATIONS CAUSED BY OR EXPOSED BY THE REMOVAL OF MATERIAL AND EQUIPMENT.
9. COORDINATE SHUTDOWN OF MECHANICAL EQUIPMENT WITH OWNER'S OPERATIONAL REQUIREMENTS.
10. DEMOLISH AND REMOVE EXISTING MOP SINK IN CHILLER PLANT. CUT AND CAP DOMESTIC HOT AND COLD WATER SUPPLIES AT HEADER, AND PLUG DRAIN.
11. PLUG AND FILL ALL EXISTING FLOOR DRAINS IN CONFLICT WITH NEW EQUIPMENT INSTALLATION LOCATIONS.
12. PATCH AND REPAIR PENETRATIONS FROM ANY ROOF MOUNTED EQUIPMENT WITH EXISTING ROOFING SYSTEM TO MAINTAIN WARRANTY.
13. CONTRACTOR IS RESPONSIBLE FOR PROVIDING CONTINUOUS SECURITY FOR CONSTRUCTION SITE, TEMPORARY FACILITY, AND TEMPORARY CHILLER PLANT.
14. PRIOR TO COMMENCEMENT OF DEMOLITION WORK:
FIELD VERIFY THE SIZES AND LOCATION OF EQUIPMENT AND SYSTEMS TO BE REMOVED.
A. RECORD ALL CHILLED WATER AND CONDENSER WATER FLOW RATES AND SETPOINTS FOR USE AFTER INSTALLATION OF NEW PIPING AND EQUIPMENT.
SUBMIT RECORD TO OWNER AND ENGINEER FOR REVIEW.
B. VERIFY THAT THE DEMO AREA IS ACCESSIBLE AND THAT DEMO TRAFFIC ROUTES ARE FREE AND CLEAR.
C. VERIFY THAT EQUIPMENT AND SYSTEMS HAVE BEEN DE-ENERGIZED AND ARE SAFE TO DISMANTLE. COMPLY WITH OWNER AND CONSTRUCTION SITE
LOCK- OUT/TAG-OUT PROCEDURES.
D. IDENTIFY ELEMENTS OF RISK ASSOCIATED WITH THE DEMOLITION WORK, AND PROVIDE CONTINGENCY PLANS TO MINIMIZE THE RISK TO THE PROJECT
FOR APPROVAL BY OWNER.
E. PROVIDE A COMPREHENSIVE DEMOLITION AND PHASING PLANT OUTLINING THE SCHEDULE OF WORK ACTIVITIES REQUIRED TO EXECUTE THE WORK.
INCLUDE MILESTONE DATES, TEMPORARY CONNECTION POINTS, ELECTRICAL POWER FEED TO TEMPORARY EQUIPMENT, INSTALLATION LOCATION OF TEMPORARY EQUIPMENT, AND PROPOSED SCHEDULE OF TEMPORARY EQUIPMENT OPERATION FOR APPROVAL BY THE OWNER AND ENGINEER.
IDENTIFY ELEMENTS OF RISK ASSOCIATED WITH THIS SCOPE OF WORK AND PROPOSED PROVISIONS TO MITIGATE RISK.
DEMOLISH ALL CHILLED WATER, CONDENSER WATER, AND
EXHAUST SYSTEM DUCTWORK, PIPING, CONTROL PANELS
AND EQUIPMENT WITHIN PROJECT BOUNDARY, WITH THE
EXCEPTION OF PIPING SHOWN ON NEW WORK PLANS.
MECHANICAL EQUIPMENT DEMOLISHED:
CH-1, 2, 3, 4, 5, 6, 7, 8;
P-1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13;
UH-1, 2.
EF-1, 2.
REFER TO DEMO AND TEMPORARY PLANT OPERATION
NOTES ON THIS SHEET.
14" CHWS
8" CHWS
8" CHWR
12" CWR
12" CWR
12" CWS
12" CWS
DEMOLISH CWS/CWR
PIPING TO VERTICAL
PIPING 3'0" AFF SHOWN
(TYP).
14" CHWR
1. IN ORDER TO MAINTAIN CHILLED WATER SUPPLY DURING RENOVATION OF THE BUILDING CHILLER PLANT, MECHANICAL CONTRACTOR SHALL SOURCE, FURNISH, AND INSTALL A TEMPORARY AIR COOLED CHILLER PLANT (CAPACITY: 1000 TONS) AND BUILDING CHILLED WATER PUMPS FOR USE DURING
CONSTRUCTION.
2. CONSTRUCTION SHALL BE PHASED SUCH THAT THE FACILITY IS USING THE TEMPORARY CHILLER PLANT ONLY BETWEEN THE MONTHS OF NOVEMBER - FEBRUARY. THE EXISTING AND/OR NEW CHILLER PLANT SHALL BE OPERATIONAL AND PROVIDING 2250 TONS OF CAPACITY MINIMUM OUTSIDE OF THIS TIME
PERIOD.
3. TEMPORARY CHILLER PLANT SHALL BE CONFIGURED TO PROVIDE AUTOMATIC OPERATION TO INCLUDE STAGING OF PUMPS AND CHILLERS. CONTRACTOR TO PROVIDE NECESSARY SERVICE AND SUPERVISION TO ENSURE CONTINUOUS, UNINTERRUPTED OPERATION 24/7.
4. TEMPORARY CONNECTION POINTS SHALL BE INSTALLED AS SHOWN ON THE DEMOLITION PLAN PRIOR TO SHUTDOWN OF EXISTING EQUIPMENT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION RELATED TO POWER SUPPLY FOR TEMPORARY EQUIPMENT.
5. INSTALLATION LOCATION OF TEMPORARY CHILLER SHALL BE DETERMINED BY THE CONTRACTOR AND COORDINATED WITH THE OWNER.
6. ROUTING OF TEMPORARY PIPING SHALL BE COORDINATED WITH CONSTRUCTION ACTIVITIES TO PROVIDE CONTINUOUS OPERATION OF TEMPORARY CHILLERS
DURING CONSTRUCTION TO MAINTAIN BUILDING CHILLED WATER SYSTEM OPERATION.
7. TEMPORARY PUMPS SHALL HAVE A CONTROLS PACKAGE THAT PROVIDES AUTOMATIC ACTIVE/STANDBY CHILLER/PUMP ENABLE AND FLOOR CONTROLS THAT
MEET CHILLER MINIMUM FLOWRATES AND MODULATE TO MEET SYSTEM DIFFERENTIAL PRESSURE AS MEASURED BY EXISTING DIFFERENTIAL PRESSURE .
PROPOSED TEMPORARY
CHILLER (TC-1 & TC-2)
AND TEMPORARY PUMP
(TP-1 & TP-2) LOCATIONS
TEMPORARY AIR-COOLED CHILLER MINIMUM REQUIREMENTS
UNIT NO.
CAPACITY
(TONS)
TC-1 500
EVAPORATOR
EWT LWT
°F °F
53 43
ELECTRICAL
ESTIMATED MAX
POWER INPUT
(KW)
53 43
V/PH/HZ
480/3/60
ESTIMATED
MCA
REMARKS:
1. CONTRACTOR SHALL COORDINATE TEMPORARY AIR COOLED DESIGN DATA WITH RENTAL SELECTION.
2. COORDINATE ELECTRICAL POWER REQUIREMENTS WITH SELECTED RENTAL CHILLER.
3. COORDINATE LOCATION OF TEMPORARY AIR COOLED CHILLERS WITH OWNER'S OPERATIONAL REQUIREMENTS.
4. COORDINATE CONNECTION POINT OF TEMPORARY AIR COOLED CHILLERS WITH EXISTING PIPING DISTRIBUTION SYSTEM
PRIOR TO INSTALLATION.
REMARKS
1, 2, 3, 4
TC-2 500 53 43 53 43 480/3/60 1, 2, 3, 4
TEMPORARY PUMP MINIMUM REQUIREMENTS
UNIT NO.
FLOW
(GPM)
TP-1 1100
ELECTRICAL
ESTIMATED MAX
MOTOR HP
V/PH/HZ
480/3/60
REMARKS:
1. CONTRACTOR SHALL COORDINATE TEMPORARY PUMP DESIGN DATA WITH RENTAL CHILLER
SELECTION.
2. COORDINATE ELECTRICAL POWER REQUIREMENTS WITH SELECTED RENTAL PUMP.
3. COORDINATE LOCATION OF TEMPORARY PUMPS WITH OWNER'S OPERATIONAL REQUIREMENTS.
4. COORDINATE CONNECTION POINT OF TEMPORARY PUMPS WITH EXISTING PIPING DISTRIBUTION
SYSTEM PRIOR TO INSTALLATION.
5. PUMPS SHALL HAVE VARIABLE FREQUENCY DRIVES.
REMARKS
1, 2, 3, 4, 5
TP-2 1100 50 480/3/60 1, 2, 3, 4, 5
HEAD
(FT)
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102HVAC DEMOLITION PLAN
D0601
MEM ARO
DEMOLITION NOTES
1/4" = 1'-0"
CHILLER PLANT DEMOLITION PLAN
TEMPORARY PLANT OPERATION NOTES
NTS
TEMPORARY CHILLER SITE PLAN
KEYED NOTES:
1. 10" TEMPORARY CHILLED WATER CONNECTION
LOCATION. DEMO TEMPORARY CONNECTION PRIOR TO
INSTALLATION OF FINAL NEW WORK CONNECTION
SHOWN ON M0201. COORDINATE SHUTDOWN OF CHILLED
WATER SYSTEM TO MAKE FINAL CONNECTION WITH
OWNER.
2. 8" TEMPORARY CHILLED WATER CONNECTION LOCATION.
TEMPORARY CONNECTION POINTS TO REMAIN AFTER
INSTALLATION OF NEW WORK WITH BLANK OFF FLANGE.
A T
O M ain
1-1 T
IE
2-1
M A
IN
M C
B S
E C 1
S E
C 2
IMMCIMMC
MCC
IMC
MCC
IMC
MCC
IMC
MCC
IMC
MCC
IMC
MCC
IMC
MCC
IMC
S
SS
SS
S
S
DPMC
HA
LA
EX
TRANSFORMER 1
E X
S P
E C
T R
A S
E R
IE
S
S W
IT
C
H B
O A
R D
SQUARE D QED2
3 3
CT XFMR
CT DISCONNECT
CTL
CT
EX EX
EX
EXEX
EXEX
JOCKY
PUMP FIRE
PUMP
SUMP
PUMP
SEWAGE
PUMP
SUMP
PUMP
2 SEWAGE
PUMP
2 AIR
COMPRESSOR
AIR
DRYER
R&E SEC. WATER PUMP
P1&P2
ROOF
SUPPLY
PUMP
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102ELECTRICAL DEMOLITION PLAN
ED0101
TZ JMS
1. REMOVE ALL EXISTING DEVICES THIS ROOM UNLESS OTHERWISE NOTED.
2. REMOVE EXISTING LUMINAIRES THIS ROOM.
3. REMOVE EXISTING DISTRIBUTION EQUIPMENT AND ASSOCIATED FEEDERS AND CIRUITS BACK TO THE POINT OF ORIGIN. REFEED EQUIPMENT THAT REMAINS FROM NEW DISTRIBUTION EQUIPMENT AS REQUIRED. REFER TO THE EQUIPMENT CONNECTION/MOTOR CONTROL SCHEDULE FOR EQUIPMENT THAT IS TO BE REFED. IN ADDITION, ASSUME (4) 20AMP/1-POLE BRANCH CIRCUITS FROM BOTH PANELS "HA" AND "LA". FIELD VERIFY EXACT QUANTITIES OF EXISTING CIRCUITS TO BE REFED AND UPDATE AS-BUILTS ACCORDINGLY. EXTEND CIRCUITS TO NEW LOCATIONS AS REQUIRED.
4. EXACT LOCATION OF THE PUMP SHALL BE FIELD VERIFIED.
KEYED NOTES :
A. REMOVE ALL ELECTRICAL EQUIPMENT ON OR IN EXISTING WALLS, CEILINGS AND PARTITIONS WHICH ARE TO BE DEMOLISHED. REMOVE ALL EXPOSED PORTIONS OF BRANCH CIRCUIT AND CONTROL VOLTAGE WIRING AND CONDUIT.
B. STOCKPILE REMOVED LUMINAIRES, POWER AND COMMUNICATION DEVICES ON JOB SITE FOR REUSE UNTIL TIME OR PROJECT CLOSEOUT, THEN REMOVE THOSE FROM SITE THAT THE OWNER DOES NOT WISH TO SALVAGE.
C. EXISTING DEVICE LOCATIONS WERE INDENTIFIED AS COMPLETELY AS POSSIBLE BY A SITE SURVEY AND BY RECORD DOCUMENTS AS AVAILABLE. BE RESPONSIBLE FOR PROPER DEMOLITION AND REWORK OF DEVICES NOT SHOWN ON
DRAWINGS TO CONFORM WITH INTENT OF DOCUMENTS.
D. WHERE EQUIPMENT IS REQUIRED TO BE DEMOLISHED, REMOVE ALL WIRING, RACEWAYS, SUPPORTING EQUIPMENT, AND
ALL OTHER RELATED ELECTRICAL INSTALLATIONS BACK TO THE SOURCE.
GENERAL DEMOLITION NOTES:
1/4" = 1'-0"
ELECTRICAL DEMOLITION PLAN
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAV AUTOMATIC AIR VENT (VALVE)
ABV ABOVE
ACCU AIR-COOLED CONDENSING UNIT
ACH AIR CHANGES PER HOUR
ACU AIR CURTAIN
AD ACCESS DOOR
AF AIR FOIL FAN
AFF ABOVE FINISHED FLOOR
AFMS AIR FLOW MEASURING STATION
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
AP ACCESS PANEL
APD AIR PRESSURE DROP
APPROX APPROXIMATE
ARCH ARCHITECT/ARCHITECTURAL
AS AIR SEPARATOR
ATD AIR TRANSFER DUCT
AUTO AUTOMATIC
AVG AVERAGE
AWT AVERAGE WATER TEMPERATURE
AXF AXIAL FAN
BB BASEBOARD RADIATION
BDD BACK DRAFT DAMPER
BF BOILER FEED WATER
BG BOTTOM GRILLE (3"-12" ABOVE FLOOR)
BHP BRAKE HORSEPOWER
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
BOD BOTTOM OF DUCT
BR BOTTOM REGISTER (3"-12" ABOVE FLOOR)
BSMT BASEMENT
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CA COMPRESSED AIR
CAP CAPACITY
CC COOLING COIL
CCW COUNTER CLOCKWISE
CD CONDENSATE DRAIN
CENTRIF CENTRIFUGAL
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CH CABINET HEATER
CHR CHILLER
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CI CAST IRON
CL CENTER LINE
CLG COOLING
CO CLEAN OUT
CO2 CARBON DIOXIDE
COMP COMPRESSOR
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUATION
CONTR CONTRACTOR
CONV CONVECTOR
CP CONTROL PANEL
CT COOLING TOWER
CU CONDENSING/ER UNIT
CU FT CUBIC FEET
CV CONSTANT VOLUME
CV CONSTANT VOLUME
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
D DRAIN OR DRYER
DB DECIBEL OR DRY BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROL
DEG.F DEGREE FAHRENHEIT
DEMO DEMOLISH
DG DOOR GRILLE
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DISCH DISCHARGE
DN DOWN
DP DIFFERENTIAL PRESSURE
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DTR DUAL TEMPERATURE RETURN
DTS DUAL TEMPERATURE SUPPLY
DWDI DOUBLE WIDTH, DOUBLE INLET
DWG DRAWING
DX DIRECT EXPANSION
E/P ELECTRIC-PNEUMATIC
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EBB ELECTRIC BASEBOARD HEATER
EC EXPANSION COMPENSATOR/JOINT
ECWR EQUIPMENT COOLING WATER RETURN
ECWS EQUIPMENT COOLING WATER SUPPLY
EDB ENTERING DRY BULB TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
EHC ELECTRIC HEATING COIL
EL/ELEV ELEVATION
ELEC ELECTRIC/ELECTRICAL
ELEM ELEMENT
ELEV ELEVATOR
EMD END OF MAIN DRIP (STEAM)
EMER EMERGENCY
ENG ENGINEER
ENT ENTERING
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
EST ESTIMATE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EV EXHAUST AIR VALVE
EVAP EVAPORATOR
EVF FUME HOOD EXHAUST AIR VALVE
EVL LAB EXHAUST AIR VALVE
H HUMIDISTAT OR HUMIDIFIER
HC HEATING COIL
HEPA HIGH EFFICIENCY PARTICULATE AIR FILTER
HG HOT GAS
HL HIGH LIMIT
HORIZ HORIZONTAL
HP HORSEPOWER OR HEAT PUMP
HPR HIGH PRESSURE CONDENSATE RETURN
HPS HIGH PRESSURE STEAM
HR HOUR
HRC HEAT RECOVERY COIL
HT HEIGHT
HTG HEATING
HTWR HIGH TEMPERATURE WATER RETURN
HTWS HIGH TEMPERATURE WATER SUPPLY
HUM HUMIDIFIER
HVAC HEAT, VENTILATION, & AIR CONDITIONING
HVU HEATING & VENTILATING UNIT
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
HX HEAT EXCHANGER
HZ HERTZ
ID INSIDE DIAMETER
IN OR " INCHES
IN W.C. INCHES WATER COLUMN
IN W.G. INCHES WATER GAUGE
INSUL INSULATION
INT INTERNAL
KW KILOWATT
KWH KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LDB LEAVING DRY BULB TEMPERATURE
LF LINEAR FEET
LPG LIQUID PETROLEUM GAS
LPR LOW PRESSURE CONDENSATE RETURN
LPS LOW PRESSURE STEAM
LRA LOCKED ROTOR AMPERES
LVG LEAVING
LVR LOUVER
LWB LEAVING WET BULB TEMPERATURE
LWT LEAVING WATER TEMPERATURE
M MOTOR OPERATOR
MAINT MAINTENANCE
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MCC MOTOR CONTROL CENTER
MECH MECHANICAL
MERV MINIMUM EFFICIENCY REPORTING VALUE
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MPR MEDIUM PRESSURE CONDENSATE RETURN
MPS MEDIUM PRESSURE STEAM
MTD MOUNTED
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
NC NOISE CRITERIA
NIC NOT IN CONTRACT
NO. OR # NUMBER
NR NOT REQUIRED
NTS NOT TO SCALE
NV NATURAL VENTILATION
OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
OBD OPPOSED BLADE DAMPER
OED OPEN END DUCT
OFCI OWNER FURNISHED/CONTRACTOR INSTALLED
OFOI OWNER FURNISHED/OWNER INSTALLED
OH OVERHEAD
OPNG OPENING
∆P/DP DIFFERENTIAL PRESSURE
P PUMP
P/E PNEUMATIC-ELECTRIC SWITCH
PA PASCAL
PCD PUMPED CONDENSATE DISCHARGE/RETURN
PCF POUNDS PER CUBIC FOOT
PCWR PROCESSED CHILLED WATER RETURN
PCWS PROCESSED CHILLED WATER SUPPLY
PD PRESSURE DROP
PF PROPELLER FAN
PG PRESSURE GAUGE
PH PHASE
PLBG PLUMBING
PRESS PRESSURE
PROP PROPELLER
PRV PRESSURE REDUCING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE IN ABSOLUTE
PSIG POUNDS PER SQUARE IN GAUGE
QTY QUANTITY
R RETURN
RA RETURN AIR
RAD RADIATION
RAF RETURN AIR FAN
REBAL REBALANCE
REG REGISTER
REV REVISED
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RM ROOM
RO RELIEF OPENING
RP RADIANT PANEL
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
RTU ROOF TOP UNIT
RV REFRIGERANT VENT OR RELIEF VALVE (VENT)
RV RETURN AIR VALVE
S/W SUMMER-WINTER
SA SUPPLY AIR OR SOUND ATTENUATOR
SCR SILICON CONTROLLED RECTIFIER
SD SMOKE DETECTOR
SENS SENSIBLE LOAD
SF SMOKE-FIRE DAMPER
SHT SHEET
SM SMOKE DAMPER
SOL SOLENOID
SP STATIC PRESSURE
SQ SQUARE
SQ. FT. SQUARE FEET
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STM STEAM
STRUC STRUCTURE/STRUCTURAL
SV SUPPLY AIR VALVE
SWSI SINGLE WIDTH, SINGLE INLET
3SF 3 HOUR SMOKE FIRE DAMPER
TC TEMPERATURE CONTROL
TD TRANSFER DUCT
TEMP TEMPERATURE
TL TOTAL LOAD
TO TRANSFER OPENING
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TYP TYPICAL
UGRD UNDERGROUND
UH UNIT HEATER (HYDRONIC OR STEAM)
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UV UNIT VENTILATOR
V VOLT OR VENT
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VERT VERTICAL
VI VIBRATION ISOLATION
VIF VERIFY IN FIELD
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
VR VACUUM RETURN
VRV VARIABLE REFRIGERANT VOLUME
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W WATT
W.G. WATER GAGE
W/ WITH
W/O WITHOUT
WB WET BULB TEMPERATURE
WC WATER COLUMN
WMS WIRE MESH SCREEN
WPD WATER PRESSURE DROP
WT WEIGHT
WTR WATER
EWB ENTERING WET BULB TEMPERATURE
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EX EXISTING
EXIST EXISTING
EXT EXTERNAL
F FAHRENHEIT
F&T FLOAT & THERMOSTATIC STEAM TRAP
F.D. FLOOR DRAIN
FA FREE AREA
FC FORWARD CURVED
FCU FAN COIL UNIT
FD FIRE DAMPER
FF FINAL FILTER
FH FUME HOOD
FLA FULL LOAD AMPERES
FLEX FLEXIBLE
FLR FLOOR
FLT FLASH TANK
FM FLOW METER
FOG FUEL OIL GAUGE
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FP FIRE PROTECTION
FPB FAN POWERED TERMINAL UNIT
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FINNED RADIATION
FSTAT FREEZESTAT
FT FEET
FV FACE VELOCITY
G NATURAL GAS
GA GAUGE
GAL GALLON
GCWR GEOTHERMAL CONDENSER WATER RETURN
GCWS GEOTHERMAL CONDENSER WATER SUPPLY
GD GRAVITY DAMPER
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GR GLYCOL RETURN
GRL GRILLE
GRV GRAVITY RELIEF VENT
GS GLYCOL SUPPLY
GV GRAVITY VENTILATOR OR NATURAL GAS VENT
TP
M0101
SUPPLY DUCT RISE
RETURN DUCT RISE
SECTION INDICATOR TOP
INDICATES SECTION NUMBER
BOTTOM INDICATES SHEET
NUMBER
VARIABLE SPEED DRIVE
EXHAUST DUCT RISE
OPPOSED BLADE VOLUME
DAMPERS
SAFETY/RELIEF VALVE
PRESSURE REDUCING VALVE
CHECK VALVE (SHOWN W/FLOW)
CONTROL VALVE (3-WAY)
CONTROL VALVE (2-WAY)
BALANCING VALVE
SOLENOID VALVE
DIRECTION OF FLOW
UNION
PIPE ANCHOR
PIPE GUIDE
OR FLEXIBLE DUCT
SINGLE LINE DUCT RISE OR DROP
ELBOW WITH TURNING VANES
T
R
S
ELECTRICAL CONNECTION (BY DIVISION
23)
ROOM PRESSURIZATION MONITOR
FREEZESTAT
FLOW SWITCH
RELAY
SWITCH
STRAINER W/BLOWDOWN VALVE
SENSING ELEMENT - AIR STREAM
SENSING ELEMENT - LIQUID SEPARABLE WELL
FLEXIBLE CONNECTION
ROUND (DIAMETER)
TRAP
EXPANSION LOOP
EXPANSION JOINT
PIPING FLOW METER
ANALOG OUTPUT
DIGITAL OUTPUT
DIGITAL INPUT
ELECTRICAL CONNECTION (BY DIVISION
26)
ANALOG OUTPUT, PNEUMATIC
SMOKE
ANALOG INPUT, PRESSURE
ANALOG INPUT, TEMPERATURE
SMOKE DETECTOR
DUCT SMOKE DETECTOR
VOLUME DAMPER
CURRENT SENSOR
BACKDRAFT DAMPER
PUMP
FIRE, SMOKE/FIRE, OR SMOKE
DAMPER
SUPPLY DUCT DROP
RETURN DUCT DROP
EXHAUST DUCT DROP
CAPPED DUCTWORK
CAPPED PIPING OR SINGLE DUCTWORK
OR
FD,SF, OR SM
EXISTING ITEM TO BE REMOVED
VALVE
"Ø
DUCT OFF-SET DN (IN DIRECTION OF FLOW)
DUCT OFF-SET UP (IN DIRECTION OF FLOW)
RECTANGULAR DUCT DIMENSIONS
(SIZE IN INCHES, FIRST DIMENSION IS SHOWN)
ROUND DUCT DIMENSIONS (DIAMETER)
MOTORIZED DAMPER
T TEMPERATURE SENSOR (IN DUCT OR PIPE)
P PRESSURE GAGE
OR
PUSH BUTTONPB
200-14 10x8
SUPPLY/ RETURN/EXHAUST SIDEWALL GRILLE-
FIRST NO. CFM, SECOND NO. TYPE
BOTTOM NO. WIDTH BY HEIGHT OF GRILLE
(REFER TO SPECIFICATION FOR AIR DEVICE TYPE)
VSD
RECTANGULAR WYE DUCT FITTING
AIR FLOW MEASURING STATION
EXISTING HVAC PIPE
NEW HVAC PIPE
EXISTING HVAC PIPE TO BE REMOVED
PIPE ELBOW DOWN
PIPE ELBOW UP
POINT OF CONNECTION (NEW TO EXISTING)
PIPE BOTTOM DROP
CLEANOUT (CO)
PIPE RISE OR DROP
ANALOG INPUT
TEMPERATURE SENSOR
OFF
ONAUTO
STARTER
HOSE DRAIN VALVE WITH CAP
MANUAL AIR VENT
PRESSURE/TEMPERATURE TEST PORT
ANALOG INPUT, FLOW
FIRE, SMOKE/FIRE, OR SMOKE DAMPER
IN RISER
FD,SF, OR SM
NEW EQUIPMENT
EXISTING EQUIPMENT
CALLOUT INDICATOR TOP
INDICATES NUMBER ON THE SHEET
BOTTOM INDICATES SHEET
NUMBER
NEW DUCT
EXISTING DUCT
DEMOED DUCT
TRIPLE DUTY VALVE
FM
AI
AIF
AIP
AIT
AO
AOP
BDD
M0101
CO
CS
DI
DO
24x12
24"Ø
DN
UP
D
E
EX-XXX
EXISTING
EQUIPMENT TYPE
OR
FM
FS
F
XXX-1
TYPE NO.
EQUIPMENT TYPE
1. THE CHILLED WATER PLANT SHALL REMAIN OPERATIONAL DURING CONSTRUCTION. MINIMUM CAPACITY NOVEMBER - FEBRUARY: 1000 TONS. MINIMUM CAPACITY MARCH - OCTOBER: 2250
TONS.
2. ALL SYSTEMS AND EQUIPMENT SHALL BE PROVIDED BY MANUFACTURERS WITH THE ABILITY TO PROVIDE SPARE PARTS AND SERVICE WITHIN 6 HOURS OF A REQUEST BY THE OWNER.
3. COMPLY WITH APPLICABLE LOCAL, STATE, FEDERAL, AND OWNER CODES AND STANDARDS DURING THE EXECUTION OF WORK DESCRIBED ON DRAWINGS AND OTHER CONTRACT
DOCUMENTS.
4. THE MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND ARE PROVIDED TO SHOW THE INTENT OF THE WORK. PROVIDE WORK AND EQUIPMENT NECESSARY TO COMPLETE THE INSTALLATION IN ACCORDANCE WITH APPLICABLE BUILDING CODES, STATE AND LOCAL BUILDING CODES, OWNERS INSURANCE UNDERWRITER(S), N.F.P.A., AND OTHER GOVERNING
AUTHORITIES HAVING JURISDICTION.
5. DUCTWORK, PIPING, AND EQUIPMENT CONNECTIONS SHOWN ON THE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE PROVIDED AS A GUIDE FOR THE INSTALLATION OF EQUIPMENT AND ASSOCIATED SYSTEMS. THE DRAWINGS ARE NOT INTENDED TO BE SCALED FOR ROUGHING IN MEASUREMENTS OR TO SERVE AS SHOP DRAWINGS. PROVIDE MINOR ADJUSTMENTS TO THE DUCTWORK AS REQUIRED TO SUIT FIELD CONDITIONS WITHOUT ADDITIONAL COST TO THE OWNER. MAJOR DEVIATIONS TO THE DESIGN REQUIRE PRIOR APPROVAL BEFORE STARTING WORK. CONTRACTOR SHALL COORDINATE WITH OTHER DISCIPLINES FROM LAYOUT THROUGH CONSTRUCTION AND RESOLVE ANY INTERFERENCES PRIOR TO INSTALLATION.
6. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR LOCATION OF WALL MOUNTED MECHANICAL ITEMS.
7. INSTALL ALL FLOOR MOUNTED HVAC EQUIPMENT, INCLUDING PUMPS, CHILLER, ETC. ON 4" CONCRETE PAD. SEE DETAIL ON SHEET M0701.
8. SUPPORTS, ROOF AND WALL OPENINGS, EQUIPMENT CONNECTIONS, EQUIPMENT ARRANGEMENT, AND ELECTRICAL POWER PROVISIONS FOR MECHANICAL EQUIPMENT ARE BASED ON PRELIMINARY INFORMATION FOR THE EQUIPMENT DESIGN BASIS SELECTION. PROVIDE AND INSTALL EQUIPMENT SUPPORTS, MAKE ROOF AND WALL OPENINGS, ADJUST CONNECTION SIZE AND TYPE, ADJUST EQUIPMENT SPACE ARRANGEMENT, AND PROVIDE ELECTRICAL BRANCH CIRCUIT AND DISTRIBUTION MODIFICATIONS BASED UPON CERTIFIED EQUIPMENT DRAWINGS, WITHOUT ADDITIONAL COST TO THE OWNER.
9. PREPARE AND SUBMIT DUCTWORK SHOP DRAWINGS FOR APPROVAL, PRIOR TO PERFORMING FABRICATION WORK. INCLUDE DUCTWORK PLANS, ELEVATIONS, AND SECTIONS, SHOWING
DUCT FITTINGS, EQUIPMENT CONNECTIONS, AND ACCESS REQUIREMENTS.
10. PROVIDE WORK IN STRICT ACCORDANCE WITH APPROVED SHOP DRAWINGS. THE OWNER OR OWNER'S REPRESENTATIVE RESERVES THE RIGHT TO REJECT WORK NOT IN ACCORDANCE
WITH THE APPROVED SHOP DRAWINGS.
11. FURNISH AND INSTALL THE NECESSARY APPURTENANCES AND MINOR AUXILIARIES REQUIRED TO MAKE EACH SYSTEM COMPLETE AND OPERABLE IN EVERY RESPECT. FURNISH AND INSTALL WORK DESCRIBED IN THE SPECIFICATIONS AND NOT SHOWN ON THE DRAWINGS, OR VICE VERSA.
12. TEST AND ADJUST INSTALLED EQUIPMENT AND SYSTEMS IN ACCORDANCE WITH CONTRACT DOCUMENTS. CORRECT DEFECTS AND SYSTEM DEFICIENCIES DISCLOSED BY TESTING, WITHOUT
ADDITIONAL COST TO THE OWNER.
13. OPERATION OF THE EQUIPMENT, DUCTWORK, OR INSTALLED PIPING DOES NOT CONSTITUTE AN ACCEPTANCE OF THE WORK BY THE OWNER. FINAL ACCEPTANCE IS DEFINED IN THE
CONTRACT DOCUMENTS.
14. LOCATIONS SHOWN ON DRAWINGS FOR PANELS ARE APPROXIMATE. COORDINATE FINAL LOCATION TO SUIT FIELD CONDITIONS, OR AS DIRECTED BY OWNER.
15. INSTALL PIPING TO HVAC HEATING AND COOLING COIL(S) AND EQUIPMENT TO ALLOW CLEAR REMOVAL SPACE FOR THE COILS, AIR FILTERS, UNIT CONTROLS, FANS, AND MOTORS.
16. COIL PIPING SHALL NOT BLOCK FILTER OR MOTOR ACCESS.
17. RUN DUCTWORK AND PIPE INSULATION CONTINUOUSLY THROUGH FLOOR, ROOF, AND WALL PENETRATIONS.
18. PENETRATIONS NOT OTHERWISE NOTED SHALL BE FURNISHED BY THE MECHANICAL CONTRACTOR.
19. EQUIPMENT MAINTENANCE ACCESS SPACE SHOWN WITH DASHED LINES.
20. INSTALL 3/4" MANUAL HIGH POINT VENTS AND LOW POINT DRAINS IN ALL RELATIVE HIGH AND LOW POINTS IN HYDRONIC PIPE SYSTEMS TO PREVENT TRAPPING OF AIR DURING FILLING AND
TO FACILITATE COMPLETE DRAINAGE.
21. CONTRACTOR SHALL PROVIDE ALL HANGERS, SUPPORTS, AND ANCHORAGE OF SYSTEM COMPONENTS.
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102LEGENDS, SYMBOLS, & GENERAL
NOTES
M0001
MEM ARO
ABBREVIATIONS
SYMBOLS GENERAL NOTES
EXISTING ROLL
UP DOOR TO
OUTSIDE
EXISTING STAIRS
EXISTING FIRE PUMP TO REMAIN & ELECTRICAL EQUIPMENT
EXISTING STEAM
SYSTEM
TO REMAIN
MAINTENANCE
AISLE, KEEP CLEAR
9'-6" AFF
CH-1 CH-2
CH-3 CH-4
CH-6
(FUTURE)
CHWP-1 CHWP-2
CHWP-6
(FUTURE)
CHWP-5
(FUTURE)CHWP-4
VFD
VFD
(FUTURE)
VFD
(FUTURE)
VFDVFD
CH-5
(FUTURE)
CHWP-3
VFD
FCU-2
ET-1
REFRIGERANT
LEAK
DETECTION
PANEL
WITH
HORN
AND
STROBE
EXISTING VENTILATION
AIR INTAKE LOUVER. BLANK
OFF ENTIRE LOUVER.
EXISTING RELIEF
AIR LOUVER. PROVIDE 36"x36" MOTOR
OPERATED ISOLATION DAMPER (RUSKIN CD60
WITH LOW LEAKAGE BLADE SEALS OR EQUAL)
ON INTERIOR FACE OF LOUVER. BLANK OFF
UNUSED PORTION OF LOUVER.
4'-0"
FCU-1
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102HVAC EQUIPMENT PLAN AND
SCHEDULES
M0101
MEM ARO
KEYED NOTES:
1. REQUIRED EQUIPMENT MAINTENANCE ACCESS
SPACE SHOWN WITH DASHED LINES. THESE
CLEARANCES SHALL BE MAINTAINED.
2. LOCATE REFRIGERANT MONITOR STROBE ABOVE
DOOR OUTSIDE OF CHILLER PLANT.
1/4" = 1'-0"
CHILLER PLANT EQUIPMENT PLAN
WATER-COOLED LIQUID CHILLER SCHEDULE
UNIT
NO.
TYPE
CAPACITY
(TONS)
REFRIGERANT NPLV
EVAPORATOR CONDENSER ELECTRICAL
EMERGENCY
POWER
MAX. UNIT
DIMENSIONS
(LxWxH)
MAX.
OPERATING
WEIGHT (LBS)
BASIS OF DESIGN
REMARKSFLUID
TYPE
MIN/MAX
GPM
EWT (ºF) LWT (ºF)
MAX PRESS.
DROP (FT)
WATER
PASSES
FOULING
FACTOR
MAX GPM EWT (ºF) LWT (ºF)
MAX PRESS.
DROP (FT)
WATER
PASSES
FOULING
FACTOR
MAX POWER
INPUT (KW)
MCA FLA MOPD V/PH/HZ VSD MANUFACTURER MODEL
CH-1 MAGNETIC BEARING 750 R-134A 0.338 WATER 810/1795 53 43 22 2 0.0001 2130 85 95 20 2 0.00025 450 741 592 1200 480/3/60 YES YES 184"x96"x108" 23830 YORK MC2 1,2
CH-2 MAGNETIC BEARING 750 R-134A 0.338 WATER 810/1795 53 43 22 2 0.0001 2130 85 95 20 2 0.00025 450 741 592 1200 480/3/60 YES YES 184"x96"x108" 23830 YORK MC2 1,2
CH-3 MAGNETIC BEARING 750 R-134A 0.338 WATER 810/1795 53 43 22 2 0.0001 2130 85 95 20 2 0.00025 450 741 592 1200 480/3/60 YES YES 184"x96"x108" 23830 YORK MC2 1,2
CH-4 MAGNETIC BEARING 750 R-134A 0.338 WATER 810/1795 53 43 22 2 0.0001 2130 85 95 20 2 0.00025 450 741 592 1200 480/3/60 YES YES 184"x96"x108" 23830 YORK MC2 1,2
PUMP SCHEDULE
UNIT NO. SYSTEM TYPE
FLUID
TYPE
CAPACITY
(GPM)
IMPELLER
SIZE (IN)
HEAD
(FT)
EFFICIENCY
SUCTION (IN)
DISCHARGE
(IN)
MOTOR EMERGENCY
POWER
BASIS OF DESIGN
REMARKS
BHP HP RPM VSD V/PH/HZ MANUFACTURER MODEL
CHWP-1 CHILLED WATER VERTICAL INLINE WATER 1800 12.45 140 85.0 8 8 74.7 100 1790 YES 480/3/60 YES ARMSTRONG SERIES 4300-8X8X13-100 HP 1, 2, 3, 4
CHWP-2 CHILLED WATER VERTICAL INLINE WATER 1800 12.45 140 85.0 8 8 74.7 100 1790 YES 480/3/60 YES ARMSTRONG SERIES 4300-8X8X13-100 HP 1, 2, 3, 4
CHWP-3 CHILLED WATER VERTICAL INLINE WATER 1800 12.45 140 85.0 8 8 74.7 100 1790 YES 480/3/60 YES ARMSTRONG SERIES 4300-8X8X13-100 HP 1, 2, 3, 4
CHWP-4 CHILLED WATER VERTICAL INLINE WATER 1800 12.45 140 85.0 8 8 74.7 100 1790 YES 480/3/60 YES ARMSTRONG SERIES 4300-8X8X13-100 HP 1, 2, 3, 4
FAN SCHEDULE
MARK TYPE CFM
SP (IN.
WC)
FAN
RPM DRIVE
MOTOR EMERGENCY
POWER WEIGHT
BASIS OF DESIGN
REMARKSBHP HP RPM VSD V/PH/HZ MANUFACTURER MODEL
EF-1 CENTRIFUGAL 2250/4500 0.5 962 DIRECT 1.1 1.5 1725 NO 460/3/60 NO 129 GREENHECK CUBE-200-15 1, 2, 3, 4
TWO-PIPE FAN COIL UNIT SCHEDULE
MARK CONFIG.
AIRFLOW
(CFM)
ESP (IN WG)
CHILLED WATER COOILING COIL ELECTRICAL
EMERGENCY
POWER
FILTER BASIS OF DESIGN
REMARKSCAPACITY
(MBH)
MIN
ROWS
EAT (°F
DB/WB)
LAT (°F
DB/WB)
GPM EWT (°F) LWT (°F)
COOLING
COIL WPD (FT)
BHP HP FAN V/PH/HZ MERV
MANUFACTUR
ER
MODEL
FCU-1 HORIZONTAL 1800 0..5 56 4 78/65 55/54 11.2 43 53 3.6 0.6 1 460/3/60 NO 8 TRANE BCHD054G1**A3M04Z000000 1
FCU-2 HORIZONTAL 1800 0..5 56 4 78/65 55/54 11.2 43 53 3.6 0.6 1 460/3/60 NO 8 TRANE BCHD054G1**A3M04Z000000 1
EXPANSION TANK SCHEDULE
MARK TYPE FLUID TYPE
VOLUME
(GAL) ACCEPTANCE (GAL) PRE-CHARGE (PSI)
SIZE DIA x
LENGTH (IN x IN) MOUNTING
BASIS OF DESIGN
REMARKSMANUFACTURER MODEL
ET-1 DIAPHRAGM WATER 70 56.5 37.7 24"x46" FLOOR MOUNTED ARMSTRONG AX-120V 1
AIR SEPARATOR SCHEDULE
MARK SIZE (DIA. X LENGTH) GPM
BASIS OF DESIGN
REMARKS
MANUFACTURER MODEL
AS-1 32"x110" 3000 Spirotherm VDT1600 FA
AS-2 28"x98" 2500 Spirotherm VDT1400 FA
REMARKS:
1. PROVIDE WITH FULLY UNLOCKED CHILLER CONTROLLER.
2. PROVIDE WITH UNIT - MOUNTED VFD.
REMARKS:
1. PROVIDE WITH TEFC, PREMIUM EFFICIENCY MOTOR.
2. PROVIDE WITH SHAFT GROUND RINGS.
3. PROVIDE VFD WITH BYPASS AND IEEE 519 LINE REACTOR.
4. PROVIDE WITH YASKAWA VSD.
REMARKS:
1. PROVIDE WITH SIGHT GLASS.
REMARKS:
1. PROVIDE WITH 120V CONDENSATE PUMP
REMARKS
1. PROVIDE WITH PREMIUM EFFICIENCY MOTOR
2. PROVIDE WITH ROOF CURB.
3. PROVIDE WITH INTEGRAL STARTER & DISCONNECT.
4. PROVIDE 2 SPEED FAN WITH AIRFLOWS AS SCHEDULED.
EXISTING
CONDENSER WATER
HEADERS TO
COOLING TOWERS
CH-1
CH-2
CH-3
CH-4
CH-6
(FUTURE)
C H
W P
-1
C H
W P
-2
C H
W P
-6 (F
U T
U R
E
C H
W P
-5 (F
U T
U R
E
C H
W P
-4
VFD-CHWP-1 VFDVFD
CH-5
(FUTURE)
C H
W P
-3
VFD-CHWP-2
M0301
M0301
M0201
M0301
24" CWR
C H
W S
C H
W R
C W
R
C W
S
C H
W S 1
C H
W R
C W
R
C W
S
24" CWS
24" CHWS
12" CHWR
C W
S
C W
R
C H
W R
C H
W S
C W
S
C W
R
C H
W S
C H
W R
8" CHWS/R TO BUILDING
(EXISTING)
AS-1
AS-2
C H
W R
FCU-2
ET-1
4 4
20" CHWS
M0201
C H
W R
14" CHWS
12" CHWS
16" CWS20" CWS
20" CHWS
24" CWS
16" CWR 12" CWR
16" CHWR 20" CHWR
14" CHWR
C W
S
C H
W S
24" CHWR
20" CHWR
8"
8"
REFRIGERANT
LEAK
DETECTION
PANEL
WITH
HORN
AND
STROBE
1"
24" CHWR
14" CHWS
8" CHWS
x
E
A
CH-1
20" CWR
3 3
3 3
M0201
VFD
(FUTURE)
VFD
(FUTURE)
400-15 12X12
500-15 12X12
500-15 12X12
400-15 12X12
18x16
FCU-1
x
(TYP 2)
(TYP 2)
1 1/2" CHWS
1 1/2" CHWR
500-15 12X12
400-15 12X12
/2
C H
W S
/2
C H
W R
Level 1
ROOF
BOTTOM OF
STRUCTURE
20" CHWS
FUTURE CHILLED
WATER CONNECTION
POINT. PROVIDE
WITH BUTTERFLY
ISOLATION VALVE
AND BLANK OFF
PLATE (TYP)
14" CHWS/R TO
BUILDING (EXISTING)
Level 1
ROOF
24" CHWR
20" CHWR 16" CHWR 12" CHWR
V F
D -C
H W
P -3
V F
D -C
H W
P -4
V F
D (F
U T
U R
E
V F
D (F
U T
U R
E
C H
W R
C H
W R
C H
W R
C H
W R
C H
W R
C H
W R
CHWP-1 CHWP-2 CHWP-3 CHWP-4
CHWP-5
(FUTURE)
CHWP-6
(FUTURE)
V F
D -C
H W
P -1
V F
D -C
H W
P -2
Level 1
ROOF
24" CWS
24" CWR
12" CWR
12" CWS
(TYP 2)
(TYP 2)
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102HVAC DUCTWORK AND PIPING PLAN -
GROUND FLOOR
M0201
MEM ARO
1/4" = 1'-0"
CHILLER PLANT PIPING & DUCTWORK PLAN
KEYED NOTES:
1. 24"x24" EA UP TO EF-1 ON ROOF ABOVE.
2. FUTURE PIPING SHOWN WITH DASHED LINES.
3. PROVIDE BLIND FLANGE DOWNSTREAM OF VALVE FOR FUTURE
CONNECTION.
4. PROVIDE SPARE TEE, ISOLATION VALVE AND BLIND FLANGE FOR
FUTURE CONNECTION.
5. 2" RELIEF VENT UP THROUGH ROOF (TYP EACH CHILLER). COMPLY
WITH MANUFACTURER'S INSTALLATION REQUIREMENTS.
6. 1" RELIEF VENT UP THROUGH ROOF (TYP EACH CHILLER). COMPLY
WITH MANUFACTURER'S INSTALLATION REQUIREMENTS.
7. MOUNT 24"x24" GRILLE 18" AFF.
8. TEMPORARY CHILLED WATER PIPING CONNECTION TO REMAIN.
PROVIDE WITH BLIND FLANGE DOWNSTREAM OF ISOLATION
VALVE AFTER COMPLETION OF NEW WORK.
9. PROVIDE 1" COPPER CONDENSATE PIPING FROM FAN COIL UNIT
TO NEAREST FLOOR DRAIN. ALL CONDENSATE DRAIN PIPING
SHALL BE INSULATED WITH MINIMUM 1/2" FOIL FACED FIBERGLASS
INSULATION INSTALLED WITH PVC JACKET.
1/4" = 1'-0"
FUTURE CONNECTION SECTION VIEW
1/4" = 1'-0"
PUMP SECTION VIEW
24" CWR BELOW
1/4" = 1'-0"
CONDENSER WATER CONNECTION
EF-1
2" RELIEF VENT
FROM BELOW.
TERMINATE IN
GOOSENECK
(TYP)
1" RELIEF VENT
FROM BELOW
TERMINATE IN
GOOSENECK
(TYP)
1" RELIEF VENT
FROM BELOW
2" RELIEF VENT
FROM BELOW
1" RELIEF VENT
FROM BELOW
2" RELIEF VENT
FROM BELOW
1" RELIEF VENT
FROM BELOW
2" RELIEF VENT
FROM BELOW
2 2
2 2
1100 Clark Avenue St. Louis, Missouri 63102
T: 314.241.6250 F: 314.241.2570
JACKSON, MS
CANNON DESIGN PROJECT NO. 03640.62
© CannonDesign 2017 All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by the Cannon Corporation
SEPT 13, 2017
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA CHILLER PLANT
586-16-102HVAC DUCTWORK AND PIPING PLAN -
ROOF
M0202
MEM ARO
1/4" = 1'-0"
CHILLER PLANT…