36C25518R0074-006.pdf
PDF 15 MB Posted
- Attached to
- Expand Parking Garage Project 589-401
- Solicitation number
- 36C25518R0074
About this file
36C25518R0074 Drawings Expand Parking Garage - vol 2 - 60 pages.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25518R0074-00004000.docx | DOCX document | |
| 36C25518R0074-00003001.pdf | ||
| 36C25518R0074-00003000.docx | DOCX document | |
| 36C25518R0074-00002000.docx | DOCX document | |
| 36C25518R0074-00002001.pdf | ||
| 36C25518R0074-00002002.pdf | ||
| 36C25518R0074-00001011.pdf | ||
| 36C25518R0074-00001013.pdf | ||
| 36C25518R0074-00001008.pdf | ||
| 36C25518R0074-00001009.pdf | ||
| 36C25518R0074-00001014.pdf | ||
| 36C25518R0074-00001006.pdf | ||
| 36C25518R0074-00001000.docx | DOCX document | |
| 36C25518R0074-00001010.pdf | ||
| 36C25518R0074-00001007.pdf | ||
| 36C25518R0074-00001003.pdf | ||
| 36C25518R0074-00001002.pdf | ||
| 36C25518R0074-00001012.pdf | ||
| 36C25518R0074-00001001.pdf | ||
| 36C25518R0074-00001005.pdf | ||
| 36C25518R0074-00001004.pdf | ||
| 36C25518R0074-009.pdf | ||
| 36C25518R0074-002.docx | DOCX document | |
| 36C25518R0074-004.pdf | ||
| 36C25518R0074-005.pdf | ||
| 36C25518R0074-008.pdf | ||
| 36C25518R0074-007.pdf | ||
| 36C25518R0074-003.pdf | ||
| 36C25518R0074-001.docx | DOCX document | |
| 36C25518R0074-000.docx | DOCX document |
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
V A
R
IE
S S
E E
P L A
N
VARIES SEE ARCH VARIES SEE ARCH VARIES SEE ARCH
1"
3/4" C
LR
T Y P
11"
MIN
11"
MIN
10"
ETS
SEE PLANx x x xxx
P/C CONCRETE
NOTE: PLACEMENT OF ADDITIONAL
REINFORCING SHOWN APPLIES TO
LANDING AT TOP OF A STAIR
FLIGHT.
ADD'L REINF AS REQ'D BY P/C
SUPPLIER DUE TO ORIENTATION
DURING HANDLING
CIP CONC W/ 6 x 6
- W1.4 x W1.4 WWR
EMBEDDED METAL
ABRASIVE NOSING
TYP, SEE ARCH &
SPECIFICATIONS
(3) #4 @ 3" O.C. x CONT.
AT TOPPING MID-DEPTH
(3) #4 @ 3" O.C. x
CONT. AT TOPPING
MID-DEPTH
TOOLED JOINT
WITH SEALANT
TOOLED JOINT
WITH SEALANT
NOTE: STAIR SLAB DESIGN BY PRECASTER TO WITH STAND HORIZONTAL AND VERTICAL
LOADS FROM CURTAIN WALL SYSTEM. COORDINATE LOADS WITH CURTAIN WALL SUPPLIER.
1'-6"
4"P/C STAIR
SLAB-ON-GRADE
#8 x 9" LONG
4" x 4" x 1/2" KOROLATH
SHIMS. GROUT AFTER
CONNECTION IS COMPLETE.
2"Ø x 4" DEEP HOLE
CAST-IN SLAB
2"Ø HOLE THROUGH
STAIR, GROUT FULL
P /C
P A
N E
L P
/C P
A N
E L
EXTERIOR INTERIOR
CONTINUOUS
SEALANT
CONTINUOUS
NON-SHRINK NON-STAIN
GROUT BETWEEN
CONNECTION TYPICAL
P /C
P A
N E
L P
/C P
A N
E L
BACKER ROD
AND SEALANT
EACH FACE
TYPICAL
CERAMIC FIBER
BLANKET INSULATION
IF FIRE RATING REQ'D.
SEE SPECS.
A T
P /C
T O
P /C
A T
P /C
T O
C A
S T
-I N
-P L A
C E
. EQUAL EQUAL
P /C
P A
N E
L P
/C P
A N
E L
O R
G R
A D
E B
E A
M O
R C
A S
T -I
N -P
L A
C E
G R
A D
E W
A L L
WELD PLATE
EXTERIOR SIDE INTERIOR SIDE
NOTES:
1. SEE DETAIL C8/S-410 FOR CONTINUOUS HORIZONTAL JOINT BETWEEN
CONNECTION.
2. (2) CONNECTIONS, MINIMUM, PER WALL PIECE.
EMBED PLATE
WITH ANCHORS
EMBED PLATE WITH
BARS x PANEL HEIGHT
NON-SHRINK
NON-STAIN
GROUT
NON-SHRINK
NON-STAIN GROUT
CONT
SEALANT
1"
5"
/2
WELD PLATE
P/C PANEL
P/C PANEL
V-GROOVE TO
MATCH PANEL
JOINTS
BACKER ROD
AND SEALANT
END OF PANEL
WHERE APPLICABLE
EMBED PLATE WITH
ANCHORS AND BARS
TYPICAL
NOTES:
1. SEE DETAIL A8/S-410 FOR JOINT BETWEEN CONNECTIONS.
2. (2) CONNECTIONS, MINIMUM, PER WALL PIECE.
NON-SHRINK
NON-STAIN GROUT
C L A
S S
B
L A
P S
P L
IC
E
STD. HOOKS
L-BAR w/ 2'-6" LEGS
3/4"
PLATE 3/8" x 4" x 4"
EMBED PLATE BY PRECASTER
HSS 8x4x3/8
P/C WALL
5/16
5/16
5/16
5/16
ANGLE 4" x 4" x 3/8" x 4" LONG
10"
ETS
SEE PLAN
P/C WALL
CIP TOPPING,
COVE SEALANT
P/C STAIR SLAB
CONNECTION BY
PRECASTER. (2)
CONNECTIONS, MIN, PER
SLAB PIECE
x x x
ETS
SEE PLAN
CIP TOPPING
CONTINUOUS BEARING PAD
CONNECTION BY
PRECASTER. (2)
CONNECTIONS, MIN, PER
SLAB PIECE
10" P/C WALL
P/C STAIR SLAB
COVE SEALANT
x x x
ETS
SEE PLANxxxx xx
TOOLED JOINT
WITH SEALANT
P/C STAIR SLAB
CONNECTIONS BY
PRECASTER
(2) CONNECTIONS PER
LANDING, MIN.CIP TOPPING
1'-0" 1'-0" 4" 10"
/2
2'-0" 2'-0"
B1
S-410
P/C COLUMN
(2) 3/4"ø INSERT/COIL RODS x 2'-6"
(GALVANIZED)
P/C SPANDREL
PANEL
P/C BEAM
P/C COLUMN COVER,
SEE D6 AND F8/S-524 SIM
10" P/C WALL
EXPANSION JOINT
TURN EXPANSION
JOINT UP 6" BETWEEN
PRECAST PIECES, TYP
1/4" x 8" x 10" x 3'-5" TALL BENT PLATE
LOCATED 1" ABOVE THE FLOOR (GALVANIZE
AND PAINT TO MATCH COLOR OF PRECAST)
ATTACH TO STAIR TOWER WALL ONLY WITH
3/8"ø HILTI KWIK BOLT TZ (STAINLESS
STEEL) EXPANSION ANCHORS AT 18" OC
PROVIDE LONG-SLOTTED HOLES IN PLATE
9.9
G
1'-0" 1'-0" 1/2"
1'-0"
8"
9.9
2.1
P/C IT BEAM
P/C COLUMN
P/C COLUMN COVER. HANG
FROM TOP MOST HAUNCH.
PROVIDE CAVITY AROUND
OTHER HAUNCHES
BEARING PAD AT TOP
MOST SUPPORT
P/C HAUNCH AT EACH
SUPPORTED LEVEL
PERFORMANCE DESIGN
BY PRECASTER TO
SUPPORT FUTURE IT
BEAM AND FLOOR LOADS
AS SHOWN IN BID ITEM 1
1/2" BEARING PADS. GLUE
TO COLUMN
OH
/2
1'-6"
4"
9"
ETS
SEE PLAN2
(2) #4 x CONT.
GRADE SLAB, SEE SHEET S-101
FOR INFORMATION
P/C STAIR
#8 x 9" LONG
4" x 4" x 1/2" KOROLATH
SHIMS. GROUT AFTER
CONNECTION IS COMPLETE.
2"Ø x 4" DEEP HOLE
CAST-IN SLAB
2"Ø HOLE THROUGH
STAIR, GROUT FULL
#4 @ 12" OC WITH STANDARD
HOOK EACH END
1'-6"
MINIMUM
SEE ARCHITECT
1'-0"
" 1
1'-0"
SEE PLAN
ETS
SEE PLAN
ETS
S E
E
A R
C H
IT
E
C T
" M
IN
IM
U M3" C
LE
A R
(1) #4 x CONTINUOUS
EMBEDDED METAL ABRASIVE
NOSING TYPICAL, SEE
SPECIFICATIONS
#4 @ 18" OC EACH WAY
(2) #4 x CONTINUOUS
GRADE SLAB, SEE
SHEET S-101 FOR
INFORMATION
1/2" FIBERBOARD
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-410
STAIR DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
F8
TYPICAL STAIR SECTION
D8
P/C STAIR/SLAB DETAIL
C8
HORIZONTAL PANEL/PANEL
DETAIL
A8
VERTICAL PANEL/PANEL DETAIL
JOINT
E5
CONNECTION DETAIL
C5
VERTICAL PANEL/PANEL
CONNECTION
A5
CORNER REINFORCEMENT DETAIL
F3
STAIR DETAIL
D3
WALL/SLAB DETAIL
F1
BEAM/SLAB DETAIL
F5
STAIR SLAB DETAIL
D1
WALL/COLUMN DETAIL
B1
COLUMN DETAIL
B3
WALL DETAIL
A3
STAIR ON GRADE DETAIL
ETS
SEE PLAN
3/8" xxx xx
TOOLED JOINT
WITH SEALANT
P/C STAIR SLAB
CONNECTIONS BY PRECASTER.
(2) CONNECTIONS, MIN., PER SLAB
PIECE. PROVIDE BOLTED CONNECTIONS
AT BASE OF SLAB AT BID ITEMS 5 AND 6 FOR
EASY REMOVAL AT TIME OF FUTURE
EXPANSION
CIP TOPPING
EXPANSION JOINT
AND P/C BEAM,
SEE F6/S-412
L 6" X6" X 1/2" X CONTINUOUS
SLAB SUPPORT ANGLE(GALV.)
WITH CONTINUOUS BEARING
PAD ATTACHED TO ANGLE
WITH 3/16" DIAMETER S.S.
SCREWS AT 12" OC
P/C TOP
LANDING SLAB
CONTINUOUS
BEARING PAD
P/C LEDGE
STAIR D CONDITION SHOWN.
FLIP DIRECTION OF ANGLE
IN OPPOSITE DIRECTION
FOR STAIR C
TOOLED JOINT
WITH SEALANT
SEE PLAN
ETS
FLASHING AND
ROOFING MATERIAL.
SEE ARCHITECTURAL.
SLOPE TO DRAIN PER
ARCHITECTURAL
DRAWINGS.
P/C SLAB
CURTAIN WALL SYSTEM,
SEE ARCHITECTURAL.
CONNECTION TO P/C SLAB
PERFORMANCE DESIGN BY
CURTAIN WALL SUPPLIER.
COORDINATE WITH PRECASTER
10"
SEE PLAN
ETS
CONNECTIONS BY PRECASTER.
(2) CONNECTIONS, MIN., PER SLAB
PIECE.
10" P/C WALL
CONTINUOUS
BEARING PAD
GUTTER AND ROOFING
MATERIAL. SEE
ARCHITECTURAL.
SLOPE TO DRAIN PER
ARCHITECTURAL
DRAWINGS.
P/C SLAB
SEALANT BOTH
SIDES
MIN (2) THREADED INSERTS AND BOLTS
REQUIRED AT EACH CONNECTION FOR
EASY REMOVAL OF ROOF FOR BID ITEMS 5 AND 6.
WELDED CONNECTION IS ACCEPTABLE
FOR BID ITEM 1 AND OTHER BID ITEM DEDUCTS
#4 HAIRPIN
10"
J O
IN
T
SEE PLAN
ETS
FLASHING AND ROOFING MATERIAL.
SEE ARCHITECTURAL. SLOPE TO
DRAIN PER ARCHITECTURAL DRAWINGS.
P/C SLAB, NEEDS TO BE DESIGNED
TO BE EASILY REMOVED AND RELOCATED.
NEEDS TO SPAN IN NORTH-SOUTH DIRECTION
CURTAIN WALL SYSTEM,
SEE ARCHITECTURAL.
CONNECTION TO P/C SLAB
PERFORMANCE DESIGN BY
CURTAIN WALL SUPPLIER.
COORDINATE WITH PRECASTER
BACKER ROD
AND SEALANT
PRECAST BEAM, DESIGN TO SUPPORT
FUTURE VERTICAL D = 0.25KLF (SERVICE)
AND FUTURE HORIZONTAL W = 0.32 KLF
(FACTORED)
CONNECTIONS BY PRECASTER.
(2) CONNECTIONS, MIN., PER SLAB
PIECE.
MIN (2) THREADED INSERTS AND BOLTS
REQUIRED AT EACH CONNECTION FOR
EASY REMOVAL OF ROOF FOR BID ITEMS
5 AND 6
#4 HAIRPIN
CONTINUOUS
BEARING PAD
3"
MIN
P/C WALL
P/C ROOF SLAB
P/C BEAM
HIDDEN HAUNCH
SECTION A-A
HIDDEN HAUNCH
PLAN
P/C WALL
BEAM CONNECTION TO
WALL PERFORMANCE
DESIGN BY PRECASTER
TOP AND BOTTOM
FOR TORSION
A
A
P/C BEAM
(2) 1/2"ø BOLTS IN
SHORT SLOTTED
HOLES
1 1/2" 3" 1 1/2"
(2) 1/2"ø HILTI KWIK BOLT TZ x 4 1/2"
(GALVANIZED)
MC12 STRINGER
L3x3x6" LONG. PROVIDE
SEALANT ALL AROUND
/4
C
L R x xxxx
P/C TEE
CIP TOPPING
P/C IT BEAM
TOOLED JOINT WITH SEALANT
1/2"x8"x8" EMBED PLATE
PERFORMANCE DESIGN BY
PRECASTER AT EACH STAIR
STRINGER WITH 2 MORE
BETWEEN STRINGERS AT
EQUAL SPACING (4) TOTAL.
DESIGN TO CARRY STAIR
LOAD.
CONNECTION FOR STRINGERS
AND TREADS TO PRECAST
EMBEDS PERFORMANCE
DESIGN BY STEEL SUPPLIER.
MC12 STRINGER
NOTE: SEE F6/S-524 FOR REMAINING INFORMATION.
/4
C
L R
5/16
EA POST
5/16
ETS
SEE PLANxxxxxxx x xxxxxxx x
HSS 6x6x3/8
MC12 STRINGER
P/C TEE FLANGE
CIP TOPPING
HSS 6x6x3/8
MC12 STRINGER
1/4" NEOPRENE
PAD AT BOTTOM
IN ADDITION TO NORMAL TOPPING
WWR, PROVIDE (8) #3 @ 6" OC x 12'-0"
LONG CENTERED UNDER STEEL POSTS
PRECASTER TO PROVIDE 4'-0" WIDE STRIP
OF WWR EQUAL TO 0.18 IN /FT. CENTER
UNDER HSS 6x6 POSTS AND PROVIDE OVER
FULL WIDTH OF PRECAST DOUBLE TEE
HSS 8x4x3/8
10" x 10" x 3/8"
STEEL PLATE EACH
SIDE
(4) 3/4"ø THROUGH BOLTS
(GALVANIZED) AT 7 1/2" SPACING
1/4" CAP PLATES WELD
ALL AROUND WATER
TIGHT
NSNS GROUT
SEE PLAN
ETS
= 763'-11 1/2"
ETW
CONNECTIONS BY PRECASTER.
(2) CONNECTIONS, MIN., PER SLAB
PIECE.
10" P/C WALL
CONTINUOUS
BEARING PAD
P/C SLAB
SEALANT BOTH
SIDES
MIN (2) THREADED INSERTS AND BOLTS
REQUIRED AT EACH CONNECTION FOR
EASY REMOVAL OF ROOF FOR BID ITEMS
5 AND 6
P/C LEDGE FOR FUTURE STAIR SLAB
(2) #4 LEDGE TIES
AT EACH CONNECTION,
MIN
GUTTER AND ROOFING
MATERIAL. SEE
ARCHITECTURAL.
SLOPE TO DRAIN PER
ARCHITECTURAL
DRAWINGS.
F
10 10.9119.9
METAL RAILING
SEE ARCHITECTURAL
M C
S
T R
IN
G
E R
M C
S
T R
IN
G
E R
P/C COLUMN
P/C BEAM
P/C SPANDREL
P/C COLUMN COVER
GRIP-STRUT PREFORMED
METAL RISERS AND
LANDING PLANKS
NOTES:
1. STEEL STAIR CONSTRUCTION: CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CALCULATIONS PREPARED BY A MISSOURI LICENSED PROFESSIONAL ENGINEER FOR THE DESIGN OF PREFABRICATED METAL RISERS, KICK PLATES, LANDING PLANKS, THEIR CONNECTIONS TO THE STEEL STRINGERS AND SUPPORT FRAMING. THE STAIRS SHALL BE DESIGNED ACCORDING TO ALL BUILDING CODE (IBC 2012) REQUIREMENTS. DESIGN FOR DEAD LOAD DUE TO SELF-WEIGHT, 100 PSF LIVE LOAD, AND MINIMUM
SEISMIC LOAD EQUAL TO 10% OF DEAD LOAD.
A. RISER CONSTRUCTION: "GRIP-STRUT" PREFORMED STEEL RISERS
B. INTERMEDIATE LANDING FLOOR SURFACE: "GRIP-STRUT" PREFORMED METAL PLANKS.
2. GENERAL CONTRACTOR TO COORDINATE REQUIRED EMBED PLATE LOCATIONS AND SIZES FOR
CONNECTIONS BETWEEN STEEL STAIR MEMBERS AND PRECAST CONCRETE WITH PRECASTER.
3. HOT-DIP GALVANIZE AND PAINT ALL STEEL.
BOLLARDS,
SEE F7/S-523
2'-0" 5'-0" 4'-0"
1'-0"
4" 12'-3" 1'-0"
F3
S-411
B6
S-411
D3
S-411
HSS 8x4x3/8
HSS 6x6x3/8" HSS 6x6x3/8"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-411
STAIR DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
F6
STAIR SLAB DETAIL
F8
ROOF SLAB DETAIL
D8
ROOF SLAB DETAIL
0 2' 4' 8'
1/4" = 1'-0"
1/4" = 1'-0"F1
STAIR - BID ITEM 5
D6
ROOF SLAB DETAIL BID ITEMS 5
AND 6
B8
HIDDEN HAUNCH DETAIL
B6
BOTTOM STAIR SECTION
F3
TOP STAIR SECTION
N
S
W
E
D3
INTERMEDIATE STRINGER
SUPPORT
B3
STAIR TOWER EXPANSION DETAIL
4" 4"
ETGB
SEE PLAN
ETS
SEE PLAN
10" P/C WALL
PANEL
CONNECTION PERFORMANCE
DESIGN BY PRECASTER.
DESIGN BASE CONNECTIONS
ASSUMING FULL HEIGHT TOWER
AS SHOWN IN BID ITEM 1 OF THESE
DRAWINGS
CIP GRADE BEAM, SEE SCHEDULE
COVE SEALANT,
SEE B5/S-502
GRADE SLAB. CAST TIGHT WITH
BOND BREAKER
COVE SEALANT,
SEE B5/S-502
SEE PLAN
SEE
PLAN
8" 4"
ETS
SEE PLAN
8" P/C WALL PANEL
ETGB
SEE PLAN
CONNECTION PERFORMANCE
DESIGN BY PRECASTER
CIP GRADE BEAM, SEE SCHEDULE
COVE SEALANT,
SEE B5/S-502
GRADE SLAB. CAST TIGHT
WITH BOND BREAKER
ETW
730'-6"
GLAZED ALUMINUM CURTAIN WALL
SYSTEM. SEE ARCHITECTURAL
PERIMETER DRAINAGE
SYSTEM, BY OTHERS,
SEE SPECIFICATIONS
3/4" TYPICAL
4'-0" WASH4"10"
1'-0" 1'-0"
ETS
SEE PLAN
F.4G xx x x xx x
P/C TEE TYPICAL
SLOPE BEARING PLATES IN BEAMS
AND SUPPORT PLATES IN COLUMNS,
AS REQUIRED TO PROVIDE UNIFORM
BEARING ON PADS, TYPICAL
P/C HAUNCH BEYOND
CIP TOPPING, TYPICAL
P/C BEAM, SEE F1/S-522 FOR INFO
WBA WABOCRETE II
SYSTEM WITH MM-800
MEMBRANE OR
ENGINEER APPROVED
EQUIVALENT. SEE
D1/S-502
CHORD STEEL, SEE PLAN
PROVIDE MINIMUM OF 1 SLEEVE THROUGH BEAM FOR
FUTURE CONDUIT, OR AS REQUIRED BY MEP DRAWINGS
#5 X 5'-0" AT EACH TEE
STEM
CIP TOPPING
CONTINUOUS
BEARING PAD
P/C LEDGE
CONNECTIONS BY
PRECASTER.
(2) CONNECTIONS,
MIN., PER SLAB PIECE.
COVE SEALANT
TOOLED JOINT WITH SEALANT
P/C STAIR SLAB
T E
E
WASH VARIES
SEE PLAN
4" 1'-0"
ETS
SEE PLAN
2.1
9.9 x x x x xx xx
CIP TOPPING
CHORD STEEL,
SEE PLAN AND
DETAIL C1/S-521
#4 x 5'-0" @ 16"
ON CENTER.
POSITION AT
MID-DEPTH
OF TOPPING.
P/C BEAMP/C STAIR TOWER
WALL
P/C SLAB
CIP TOPPING
WBA WABOCRETE II SYSTEM
WITH MM-800 MEMBRANE OR
ENGINEER APPROVED
EQUIVALENT. SEE D3/S-502
COVER PLATE ANCHOR
TO WALL SIDE ONLY.
SEE SPECIFICATIONS TOOLED JOINT
WITH SEALANT
CONNECTIONS BY
PRECASTER. (2)
CONNECTIONS,
MIN., PER SLAB
PIECE.
TOOLED JOINT
WITH SEALANT
P/C TEE
3" 2"
ETGB
SEE PLAN
ETS
SEE PLAN
CIP GRADE BEAM,
SEE SCHEDULE
PERIMETER DRAINAGE
BY OTHERS, SEE
SPECIFICATIONS
COVE SEALANT
GRADE SLAB CAST TIGHT
10" P/C WALL
EXTERIOR GRADE,
SEE CIVIL
3/4"ø x 2'-6" COIL ROD
AND INSERT @ 18" OC
WITH (2) #4 x CONT
CONNECTION PERFORMANCE
DESIGN BY PRECASTER.
DESIGN BASE CONNECTIONS
ASSUMING FULL HEIGHT TOWER
AS SHOWN IN BID ITEM 1 OF THESE
DRAWINGS
1'-0"
2"
4"
ETS
SEE PLAN
(3) #4 x CONTINUOUS
SLAB ON GRADE
CIP CONCRETE,
SEE CIVIL
DRAWINGS
1/2" JOINT FILLER
#4 x 4'-0" @ 12" OC
CENTERED ON JOINT,
PLACE BAR IN DOWEL
SLEEVE ON PARKING
STRUCTURE SIDE OF
JOINT
P/C WALL
CIP GRADE BEAM
FACE OF WALL
BEYOND
#4 @ 12" OC WITH
STANDARD HOOK
BY PRECASTER
11"1"
4"
F.4
P/C WALL
EXPANSION JOINT
1/4" x 8" x 10" x 3'-5" TALL BENT PLATE LOCATED
1" ABOVE THE FLOOR (GALVANIZE AND PAINT TO
MATCH COLOR OF PRECAST) ATTACH TO STAIR
TOWER WALL ONLY WITH 3/8"ø HILTI KWIK BOLT
TZ (STAINLESS STEEL) EXPANSION ANCHORS AT
18" OC. PROVIDE LONG-SLOTTED HOLES IN
PLATE
TURN EXPANSION
JOINT UP 6" BETWEEN
PRECAST PIECES, TYP
P/C SPANDREL
PANEL
P/C COLUMN
3/4"ø INSERT/COIL ROD x 2'-6"
(GALVANIZED)
P/C BEAM
P/C BEAM
LEDGE BELOW
STAIR TOWERGARAGE
ETS
SEE PLAN
(3) #4 x CONTINUOUS
SLAB ON GRADE
#4 x 4'-0" @ 18" OC
CENTERED ON JOINT.
PLACE BAR IN DOWEL SLEEVE
ON STAIR TOWER SIDE OF JOINT
P/C WALL
CIP GRADE BEAM
FACE OF WALL
BEYOND
#4 @ 12" OC WITH
STANDARD HOOK
BY PRECASTER
TOOLED JOINT
WITH SEALANT
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-412
STAIR DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
B8
GRADE BEAM/WALL DETAIL
D8
GRADE BEAM/WALL DETAIL
D6
BEAM/WALL DETAIL
F6
BEAM/WALL DETAIL
B6
GRADE BEAM/WALL DETAIL
F8
EDGE OF SLAB DETAIL AT STAIR
EXTERIOR DOORWAY
B3
COLUMN PLAN DETAIL
D3
SLAB DETAIL AT DOORWAY
8" 8" 8"
2'-0"
M
IN
IM
U M
U N
O O
N P
L A
N
S PROVIDE WASH WHERE
INDICATED ON PLANS.
WASH IS 4'-0" WIDE UNO
ON PLANS
T.O. FOUNDATION
SEE FOUNDATION PLAN
ETS
SEE PLAN
ETS
SEE PLAN
SLAB ON GRADE
CMU WALL WITH #5 @ 8"
VERTICAL AND ALL CELLS
GROUTED SOLID. EXTEND
EVERY THIRD VERTICAL BAR
2'-0" INTO MASONRY ABOVE
2'-8".
CMU WALL WITH #4 @
2'-0" ON CENTER ABOVE
2'-8". GROUT CELLS
SOLID AT REINFORCING.
SEE DETAIL F5/S-501 AT
ENDS.
SLAB ON GRADE
CAST-IN-PLACE
FOOTING
#5 x 3'-0" DOWELS
@ 8" ON CENTER
WITH STANDARD
HOOK
1/2" JOINT FILLER, TYPICAL
NOTES:
1. SEE DETAIL E5/S-501 FOR HORIZONTAL REINFORCEMENT. SEE
DETAIL F3/S-501 AT OPENING.
2. GROUT CELLS SOLID WHERE MEP EQUIPMENT IS MOUNTED TO
WALL. SEE MEP DRAWINGS.
SEE DETAIL A1/S-501
AND DETAIL C1/S-501
FOR TOP OF WALL
DETAILS
(2) # 5 x CONTINUOUS
EXTEND 1'-6" INTO
INTERSECTING
FOUNDATION
DAMPPROOFING, BOTH SIDES
C L E
A R
M
IN
IM
U
M
1/8" GAP BETWEEN
ANGLE AND WALL
TYPICAL
4" MIN
8" CMU WALL WITH #4
@ 2'-0" OC GROUT
CORES SOLID AT REINFORCING.
GROUT CELLS SOLID WHERE MEP
EQUIPMENT IS MOUNTED TO WALL.
SEE MEP DRAWINGS.
P/C TEE AND CIP
TOPPING
SLOT TOP CMU BLOCK
AS REQUIRED TO SLIDE
PAST REBAR
L 6x4x5/16 (LLV) x 0'-8"
LONG @ 4'-0" ON CENTER
(GALVANIZED) WITH (2) 3/8"Ø
(GALVANIZED) EXPANSION
ANCHORS WITH 2 1/2"
MINIMUM EMBED TYPICAL
@ 5" OC IN SHORT-SLOTTED
HOLES, PERPENDICULAR TO
WALL. PROVIDE FIRST
CONNECTION AT 4'-0" FROM
CORNERS. PROVIDE
L8x6x7/16 (LLH) AT EAST
WALL
BOND BEAM WITH (2)
#5 CONTINUOUS, SEE
DETAIL C5/S-501 AT
CORNERS
SEE DETAIL E1/S-501
FOR BOTTOM OF WALL
DETAIL
FIRE RATED JOINT,
SEE SPECIFICATIONS
C L E
A R
M
IN
IM
U
M
1" CLEAR
TYPICAL
8" CMU WALL WITH #4
@ 2'-0" ON CENTER GROUT
CORES SOLID AT REINFORCING.
GROUT CELLS SOLID WHERE
MEP EQUIPMENT IS MOUNTED
TO WALL. SEE MEP DRAWINGS.
P/C TEE AND CIP
TOPPING
SLOT TOP CMU BLOCK
AS REQUIRED TO SLIDE
PAST REBAR
FIRE RATED JOINT,
SEE SPECIFICATIONS
BOND BEAM WITH (2)
#5 CONTINUOUS, SEE
DETAIL C5/S-501 AT
CORNERS
FIRE RATED JOINT,
SEE SPECIFICATIONS
SEE DETAIL E1/S-501
FOR BOTTOM OF WALL
DETAIL
1 1/2" t
CUT EVERY OTHER HORIZONTAL
BAR @ JOINT EXCEPT TOP AND
BOTTOM BARS
NOTES:
1. 20' MAXIMUM JOINT SPACING AND NO MORE THAN 10' FROM CORNER, U.N.
V-GROOVE t/8 DEEP t
1 1/2"
EXTEND TOP AND BOTTOM
BARS AND EVERY OTHER
HORIZONTAL BAR @ JOINT
V-GROOVE t/8 DEEPCLASS B LAP SPLICE
1 1/2"
CLEAR
2'-0"
MINIMUM
TYPICAL
NOTES:
1. ALL OPENINGS WITH A DIMENSION OF 4" OR GREATER SHALL BE TRIMMED
AS SHOWN.
2. THIS REINFORCEMENT IS IN ADDITION TO ANY REINFORCEMENT INDICATED
ON THE DRAWINGS.
(2) #5, ONE BAR EACH FACE,
ALL FOUR SIDES OF OPENING
EFFECTIVE OPENING LENGTH
(1'-0" MAXIMUM)
(2) #5 x 4'-0", ONE BAR EACH FACE, DIAGONAL ALL FOUR CORNERS
CLASS B
LAP SPLICE
VERTICAL BARS SHOWN @
CORNER REINFORCING ONLY
SAME SIZE AND SPACING
AS HORIZONTAL BARS
20 db > 1'-0" db = DIAMETER OF BAR
2" CLEAR
ALTERNATE ENDS
VERTICAL BARS SHOWN @
HOOKS ONLY
END OF WALL
OR JAMB
END OF WALL
OR JAMB 4"
E Q
E Q
4"
/4
/4
SINGLE ROW OF VERTICAL REINFORCINGVERTICAL REINFORCING EACH FACE
HOOK ENDHOOK END
NOTES:
1. GROUT SOLID AT REINFORCING.
B7
S-501
F5
S-501
NOTES:
1. LAP ALL VERTICAL AND HORIZONTAL REINFORCING 48 BAR DIAMETERS.
2. JAMB HEAD AND SILL REINFORCING SHALL BE THE SAME AS THE TYPICAL WALL REINFORCING AND
PLACED IN ADDITION TO THE TYPICAL WALL REINFORCING.
3. UNLESS OTHERWISE NOTED ON THE DRAWINGS, THERE SHALL BE ONE ADDITIONAL BAR ADDED AT
ALL END WALLS, CORNERS AND INTERSECTIONS.
4. FOR UNIT MASONRY MOCK UP REQUIREMENTS, COLOR VARIATIONS, ADMIXTURES REQUIREMENTS, AND MATERIAL AND FIELD TOLERANCES, SEE SPECS.
5. WHERE MASONRY BEARS ON STRUCTURAL STEEL BEAM WITH FLANGES NARROWER THAN ACTUAL
MASONRY THICKNESS, WELD 1/4" CONTINUOUS PLATE TO BEAM FLANGE - PLATE WIDTH TO BE
NARROWER THAN MASONRY THICKNESS BY 1/4" TO 3/8" EACH SIDE.
6. SEE DETAIL E5/S-501 AND DETAIL E1/S-501 FOR TYPICAL CMU WALL REINFORCING.
PROVIDE BEARING
PAD OR BOND
BREAKER AT
EXPANSION JOINT
LINTEL ANGLE,
TYPICAL
#5 MINIMUM REINFORCING
AROUND ALL OPENINGS
NOTE: REINFORCING
WHICH IS NOT
CONTINUOUS BETWEEN
SUPPORTS MUST BE
PROVIDED IN ADDITION TO
THE MINIMUM REQUIRED
REINFORCING STEEL
24" MINIMUM, BUT NOT
LESS THAN 48 BAR
DIAMETERS
CIP FOUNDATION, SEE
FOUNDATION PLAN
3/8" STACKED JOINT
WITH EVERY OTHER
ALTERNATE HORIZONTAL
REINFORCING BAR CUT
AT JOINT
2'-0" WIDE DAMPPROOFING OVER
6" WIDE x CONTINUOUS 12 GAUGE
GALVANIZED SHEET METAL STRIP,
TYPICAL BELOW GRADE
BACKER ROD EACH SIDE
SILICONE SEALANT EACH
SIDE
3/4" RAKED JOINT
EACH SIDE
VERTICAL WALL
REINFORCEMENT
TYPICAL
NOTES:
1. LOCATIONS OF ALL CONTROL JOINTS MUST BE VERIFIED WITH THE ENGINEER. MAXIMUM
SPACING NOT TO EXCEED 24'-0" UNLESS NOTED OTHERWISE.
(2) #5 x CONTINUOUS
(2) #5 x CONTINUOUS
(2) #5 x
DOWELS
TYPICAL
2'-6"
WELDED PREFABRICATED TEE
SECTION LAPPED WITH TYPICAL
HORIZONTAL JOINT REINFORCING,
9 GAUGE @ 16" ON CENTER TYPICAL
(1) #5 VERTICAL BAR
IN FILLED CELL AT
INTERSECTION
(1) #5 VERTICAL BAR
IN FILLED CELL AT
CORNER
(1) #5 VERTICAL BAR
IN FILLED CELL AT
END
CUT INSIDE BARS
AND BEND OUTSIDE
BARS AROUND
CORNERS
WELDED PREFABRICATED CORNER
SECTION MAY BE USED IN LIEU OF
FIELD BENDING AT CONTRACTORS
OPTION
LESS THAN 3'-6"
SPAN ANGLE SIZE
(2) L 3 1/2 x 3 1/2 x 1/4
3'-6" TO 5'-0" (2) L 4 x 3 1/2 x 1/4 (LLV)
5'-0" TO 7'-6" (2) L 5 x 3 1/2 x 3/8 (LLV)
7'-6" TO 11'-6" (2) L 6 x 3 1/2 x 3/8 (LLV)
LOOSE LINTEL SCHEDULE
(8" CMU WALL)
REINFORCING
AROUND OPENING,
SEE DETAIL F3/S-501
TYPICAL WALL
REINFORCEMENT
LINTEL ANGLES
(GALVANIZED), SEE
SCHEDULE BELOW
LINTEL ANGLES
(GALVANIZED), SEE
SCHEDULE BELOW
REINFORCING
AROUND OPENING,
SEE DETAIL F3/S-501
TYPICAL WALL
REINFORCING
SECTION A-ASECTION AT OPENING
NOTES:
1. LINTEL ANGLES LENGTH EQUALS CLEAR SPAN PLUS 1'-0" FOR 8" CMU WALLS.
2. WELD ANGLES TOGETHER WITH 1/4" WELD FULL HEIGHT OF VERTICAL LEGS EACH END.
A A
1"
ETS
SEE PLAN
ETS
SEE PLAN
E
SLAB ON GRADE
P/C PANEL,
SEE F1/S-512
CMU WALL , SEE
E1/S-501
SLAB ON GRADE
CIP FOOTING,
SEE E1/S-501
1/2" JOINT FILLER
BACKER ROD AND SEALANT
OVER TOP AND AT ENDS
CLOSE OFF GAP BELOW GRADE
WITH 6" WIDE STRIP OF PROTECTION
BOARDDAMPPROOFING,
BOTH SIDES
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-501
STRUCTURAL DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
E1
MASONRY WALL DETAIL
C1
SLAB/WALL DETAIL
A1
WALL/TEE DETAIL
B3
VERTICAL CONTROL JOINT IN
WALL DETAIL
A3
VERTICAL CONSTRUCTION JOINT
IN WALL DETAIL
F1
WALL OPENING DETAIL
D3
WALL CORNER REINFORCEMENT
DETAIL
C3
WALL CORNER REINFORCEMENT
DETAIL
F5
TYPICAL CMU WALL REINFORCING
DETAIL
F3
TYPICAL WALL/OPENING
REINFORCEMENT DETAIL
A5
MASONRY WALL CONTROL JOINT
DETAIL
C5
MASONRY WALL BOND BEAM
INTERSECTION REINFORCEMENT
DETAIL
E5
MASONRY WALL HORIZONTAL
JOINT REINFORCEMENT DETAIL
B7
CMU LINTEL ANGLE DETAIL
F7
MASONRY WALL DETAIL
P/C COLUMN
TOOLED JOINT
AND SEALANT
OVER INVERTED
TEE BEAM,
SEE DETAIL
F5/S-502
WASH LINE WHERE SHOWN
ON STRUCTURAL PLANS AND
DETAILS
TEE/TEE JOINT
WITH SEALANT,
SEE DETAIL
F5/S-502
COVE SEALANT AROUND
COLUMN
INTERIOR VIEW AT COLUMN EXTERIOR VIEW AT COLUMN
TOOLED JOINT
AND SEALANT,
SEE DETAIL
F5/S-502
CIP TOPPING
P/C COLUMN
BACKER ROD AND
SEALANT @ COLUMN
FACE AND DOWN
BEAM JOINT, SEE
DETAIL D5/S-502
P/C SPANDREL
WASH WHERE
SHOWN ON
STRUCTURAL PLANS
AND DETAILS
COVE SEALANT, SEE
DETAIL B5/S-502
SPANDREL FLUSH TO INTERIOR CONDITION
/4
3/4"
NOTES:
1. PREPARE SURFACE FOR PRIMER APPLICATION AND ALLOW FOR
PRIMER TO CURE PROPERLY PRIOR TO INSTALLING SEALANT.
2. SEE SPECIFICATIONS FOR APPROVED MATERIALS.
1/2" MINIMUM - 3/4" MAXIMUM
THROAT THICKNESS
FINISHED FLOOR SURFACE
WALL, COLUMN, OR
CURB FACE
P/C BEAM
1/2" MINIMUM - 3/4" MAXIMUM
THROAT THICKNESS
P/C COLUMN
BACKER ROD
NOTES:
1. PREPARE SURFACE FOR PRIMER APPLICATION AND ALLOW FOR PRIMER
TO CURE PROPERLY PRIOR TO INSTALLING SEALANT.
2. SEE SPECIFICATIONS FOR APPROVED MATERIALS.
2"
CIP TOPPING
TRAFFIC TOPPING
(FLOOR SURFACE)
CONTRACTOR TO PROVIDE
STRAIGHT FINISHED LINE
PROVIDE 1/4" DEEP SAW CUT AT
TERMINATING EDGE OF COATING,
ALLOW BASE COAT TO FLOW INTO
THE SAW CUT
LIMITS OF SURFACE
PREPARATION
LIMITS OF SURFACE
PREPARATION
CONTRACTOR TO PROVIDE
STRAIGHT FINISHED LINE
TRAFFIC TOPPING
(FLOOR SURFACE)
VERTICAL SURFACE
(BEAM OR COLUMN)
COVE SEALANT, SEE
DETAIL B5/S-502
J O
IN
T
D E
P T
H
/1
1/2"
/2
M
A X
IM
U
M S
E A
L A
N T
D E
P T
H
CIP TOPPING
3/16" TO 1/4" EDGE RADIUS
TYPICAL
BOND
BREAKER
P/C TEE
TOOL JOINT (SAW CUT JOINT
PROHIBITED). PREPARE EDGE
AND FILL WITH FLEXIBLE
SEALANT. INSTALL SEALANT
EVENLY AND RECESS 1/16"
BELOW SURFACE
DO NOT OVERFILL JOINT
NOTES:
1. CONTROL JOINT MUST BE TOOLED IN PLASTIC CONCRETE AND DIMENSIONS AS DETAILED
WILL BE MAINTAINED IN SET CONCRETE. SAW CUTTING OF CONTROL JOINT IN HARDENED
CONCRETE WILL NOT BE PERMITTED.
4" BLOCKOUT PER
EXPANSION JOINT
SUPPLIER REQUIREMENTS
B L O
C K
O U
T P
E R
E X
P A
N S
IO
N
J O
IN
T
S U
P P
L
IE
R R
E Q
U
IR
E M
E N
T S
CONTINUOUS SEALANT
WALL
ELASTOMERIC
CONCRETE HEADER
CONNECTION PER EXPANSION
JOINT SUPPLIER
WBA WABO CRETE II SYSTEM WITH
MM-800 MEMBRANE OR ENGINEER
APPROVED EQUIVALENT. DELAY
MEMBRANE INSTALLATION AT LEAST
30 DAYS AFTER PLACING CONCRETE.
TURN JOINT UP AT ENDS MIN. 6"
BETWEEN COLUMN AND WALL
1/4" CHAMFER
MEMBRANE FLAP
4"BLOCKOUT PER
EXPANSION JOINT
SUPPLIER REQUIREMENTS
B L O
C K
O U
T P
E R
E X
P A
N S
IO
N
J O
IN
T
S U
P P
L
IE
R R
E Q
U
IR
E M
E N
T S
2"
5" MIN
MEMBRANE FLAP
ELASTOMERIC CONCRETE
HEADER (TYPICAL)1/4" CHAMFER
(TYPICAL)
WBA WABO CRETE II SYSTEM WITH
MM-800 MEMBRANE OR ENGINEER
APPROVED EQUIVALENT. DELAY
MEMBRANE INSTALLATION AT LEAST
30 DAYS AFTER PLACING CONCRETE.
TURN JOINT UP AT ENDS MIN. 6"
BETWEEN COLUMN AND WALL
STAINLESS STEEL OR ALUMINUM
NON-SLIP HINGED COVER PLATE.
ANCHOR TO STAIR/ELEVATOR TOWER
WALLS ONLY. ROUND EDGES AND
COUNTERSINK ANCHORS SEE SPECS.
SEE NOTE 1.
NOTE:
1. INSTALL ALUMINUM TREAD PLATES WITH A MINIMUM NUMBER OF BUTT JOINTS. JOINTS MUST BE EVEN
AND FLUSH. HOLD END OF PLATE 2" AWAY FROM VERTICAL SURFACES (WALLS, COLUMNS, CURBS).
2. SEE F1/S-502 FOR ANTICIPATED MOVEMENTS.
ELEVATOR WALL
CONNECTIONS PER COVER PLATE
MANUFACTURER
B L O
C K
O U
T P
E R
E X
P A
N S
IO
N
J O
IN
T
S U
P P
L
IE
R R
E Q
U
IR
E M
E N
T S
4"BLOCKOUT PER
EXPANSION JOINT
SUPPLIER REQUIREMENTS
MEMBRANE FLAP
ELASTOMERIC CONCRETE
HEADER (TYPICAL)
1/4" CHAMFER (TYPICAL)
NOTE: JOINT MUST BE ADA COMPLIANT. SEE F1/S-502 FOR ANTICIPATED MOVEMENTS.
SEE D1/S-502 FOR VERTICAL CONDITION AT COLUMNS, SIM
WBA WABO CRETE II SYSTEM WITH
ME-600 MEMBRANE OR ENGINEER
APPROVED EQUIVALENT. DELAY
MEMBRANE INSTALLATION AT LEAST
30 DAYS AFTER PLACING CONCRETE.
TURN JOINT UP AT ENDS MIN. 6"
BETWEEN COLUMN AND WALL
INTERIOR VIEW AT COLUMN EXTERIOR VIEW AT COLUMN
TOOLED JOINT
AND SEALANT,
SEE DETAIL
F5/S-502
CIP TOPPING
BACKER ROD AND
SEALANT @ COLUMN
FACE AND DOWN
BEAM JOINT, SEE
DETAIL D5/S-502
P/C SPANDREL
WASH WHERE
SHOWN ON
STRUCTURAL PLANS
AND DETAILS
COVE SEALANT, SEE
DETAIL B5/S-502
SPANDREL FLUSH TO EXTERIOR CONDITION
P/C COLUMN
EXPANSION JOINT MOVEMENT TABLE
STAIR OPENING
MAX MIN
TEMPERATURE MOVEMENTS
CREEP AND SHRINKAGE
INITIAL OPENING WIDTH
TOTAL OPENING WIDTH
NOTE: ANTICIPATED SHEAR MOVEMENT DUE TO CREEP AND
SHRINKAGE AND TEMPERATURE = 1.72" AT STAIR TOWER
0.5" AT BRIDGE
BRIDGE OPENING
MAX MIN
0.61" 0.29" 0.63" 0.32"
1.11" -0.65" 1.00" -0.60"
4" 4" 4" 4"
5.72" 3.64" 5.58" 3.72"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-502
WATERPROOFING DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
F3
SEALANT ISOMETRIC AT
DRIVE-THRU
F7
SPANDREL/COLUMN SEALANT
B5
COVE SEALANT DETAIL
D5
BACKER ROD AND SEALANT
DETAIL
B1
TRAFFIC TOPPING DETAIL
(HORIZONTAL TERMINATION)
B3
TRAFFIC TOPPING DETAIL
(VERTICAL TERMINATION)
F5
TOOLED JOINT AND SEALANT
DETAIL
D1
EXPANSION JOINT DETAIL (STAIR)
D3
EXPANSION JOINT DETAIL (STAIR)
F1
EXPANSION JOINT MOVEMENTS
D7
EXPANSION JOINT (BRIDGE)
B7
SPANDREL/COLUMN SEALANT
C L E
A R
ETS
SEE PLAN
1/2" TOOLED JOINT FILL WITH
SEALANT. GRIND EDGES
SMOOTH AND STRAIGHT
PRIOR TO SEALING
#3 x 2'-6" AT 18" ON CENTER AT
MID-DEPTH, GREASE AND WRAP
ONE SIDE OF DOWEL AT SECOND
POUR
C L E
A R
ETS
SEE PLAN
3/8"ø SMOOTH BAR x 2'-6" @
36" OC AT MID-DEPTH.
GREASE ENTIRE BAR TO
PREVENT BOND
1 1/2" DEEP TOOLED JOINT FILL
WITH SEALANT. GRIND EDGES
SMOOTH AND STRAIGHT PRIOR
TO SEALING
1'-0"
1'-0"
4'-0" WASH
ETS
SEE PLAN
GRID
(3) #4 x CONTINUOUS 2
SLAB ON GRADE
ASPHALT PAVING,
SEE CIVIL
DRAWINGS
4" M
IN
ETS
SEE PLAN
GRID
SLAB ON GRADE
P/C COLUMN
TOOLED JOINT
WITH SEALANT
1/2" JT FILLER
BTWN SLAB
AND COL
CONTROL OR
CONSTR JT
HAND TOOLED JT W/
SEALANT AROUND COL
OR FORMED CONSTR
JOINT AS REQ'D (MAY
USE SECONDARY POUR
@ CONTRACTOR'S OPTION)
6"
/2
W
A S
H
M
IN
IM
U
M
SEE FOUNDATION PLAN
T.O. FOUNDATION
2'-0 SQUARE
MINIMUM
TOOLED JOINT AND
SEALANT
FLOOR DRAIN SYSTEM, SEE
MECHANICAL DRAWINGS
(2) #4 x 6'-0"
FOUR SIDES
CONCRETE SLAB ON GRADE,
SEE PLAN FOR TYPICAL SLAB
REINFORCING
SEE MECHANICAL
DRAWINGS FOR PIPING
1'-0"
2" 1'-0"
ETS
SEE PLAN
GRID
(3) #4 x CONTINUOUS
SLAB ON GRADE
CIP CONCRETE,
SEE CIVIL
DRAWINGS
EXTERIOR PARKING STRUCTURE
1/2" JOINT FILLER
#4 x 4'-0" @ 12" ON CENTER,CENTERED ON
JOINT, PLACE BAR IN DOWEL SLEEVE ON
PARKING STRUCTURE SIDE OF JOINT
1'-6"
SQUARE
ETS
SEE PLAN
SLAB ON GRADE
6" STANDARD GALVANIZED STEEL PIPE
WITH 1/4" CAP PLATE, SET PLUMB
9" x 9" x 1/2" GALVANIZED STEEL PLATE
WITH (4) 3/4"Ø x 4 3/4" EMBEDMENT
STAINLESS STEEL EXPANSION
ANCHORS @ 6 1/2" ON CENTER
1/4" NEOPRENE PAD, SEALANT ALL
AROUND
3/16"
NOTES:
1. PAINT ENTIRE PIPE GUARD ASSEMBLY TRAFFIC YELLOW.
3/16"
GRIND SMOOTH
1'-6"
2'-3" 6" 1'-9"
1'-5 1/2" 1'-6 1/2"
GRADE BEAM GB-3
SEE SCHEDULE
GRADE BEAM GB-5
SEE SCHEDULE
EXTEND TOP AND BOTTOM REINFORCING
INTO GB-3 BY DEVELOPMENT LENGTH
C
DRILLED
PIER
L
OH
1'-0"
1/2"
1'-0"
ETS
SEE PLAN
C
(3) #4 x CONTINUOUS
PHASE 2 NEW SOG PHASE I EXISTING SOG
1/2" JOINT FILLER
#4 x 3'-0" @ 12" OC, DRILL AND EPOXY
INTO EXISTING GRADE SLAB WITH HILTI
HIT-RE 500, WITH 6" EMBED. WRAP WITH
2" DIAMETER x 12" LENGTH PIPE
INSULATION NEAR JOINT
SLOPE DOWN FROM
THIS EDGE
4'-0" WASH 4'-0" WASH
ETS
SEE PLAN
G
TOOLED JOINT
WITH SEALANT
SLAB ON GRADE
1'-9" 1/2" 1'-0" 1'-0"
4'-0" WASH
ETS
SEE PLAN
G
ASPHALT PAVING,
SEE C7/S-510 SLAB ON GRADE,
SEE C7/S-510
BACKER ROD AND
SEALANT ALL
AROUND
PRECAST COLUMN
COVER
PRECAST COLUMN
1/2" BEARING PAD,
GLUE TO COLUMN
11"1"
ETF
SEE PLAN
ETW
SEE PLAN
ETS
SEE PLAN
2'-0" WIDE CIP FOOTING,
CENTER UNDER WALL
(2) # 5 x CONTINUOUS
EXTEND 1'-6" INTO
INTERSECTING PIER CAP
SLAB ON GRADE,
SEE CIVIL
CONNECTION PERFORMANCE DESIGN
BY PRECASTER. MINIMIZE NUMBER OF
CONNECTIONS TO GREATEST EXTENT
POSSIBLE FOR FUTURE REMOVAL.
PROVIDE BOLTED CONNECTION INSTEAD
OF WELDED
P/C WALL PANEL. DESIGN FOR EASY
FUTURE REMOVAL AND RE-USE
EXTERIOR GRADE,
SEE CIVIL
SLOPE
1/2"
PROVIDE RECESSED LIFTING
LOOPS/INSERTS. DO NOT REMOVE
AFTER ERECTION BUT LEAVE IN
PLACE. PROTECT FROM WEATHER
AND HIDE FROM VIEW WITH PLASTIC
CAPS AND SEALANT
3/4"ø x 2'-6" COIL ROD AND INSERT @ 4'-0" OC WITH (2) #4 x CONT
1'-6"Ø
ETS
SEE PLAN
SEALANT ALL AROUND
ASPHALT PAVING, SEE CIVIL
DRAWINGS
(4) #4 VERT WITH #3 TIES
3 @ 2" TOP, REM @ 12" OC
3/16"
6" STANDARD GALVANIZED STEEL PIPE
WITH 1/4" CAP PLATE, SET PLUMB
9" x 9" x 1/2" GALVANIZED STEEL PLATE
WITH ANCHORS @ 6 1/2" ON CENTER
1/4" NEOPRENE PAD
3/16"
GRIND SMOOTH
(4) 3/4"ø HILTI HDI DROP IN
ANCHORS AND BOLTS
(STAINLESS)
NOTES:
1. PAINT ENTIRE PIPE GUARD ASSEMBLY TRAFFIC YELLOW.
/2
1'-6"
SQUARE
2'-0"
1 1
NOTE:
1. PAINT ENTIRE PIPE GUARD ASSEMBLY TRAFFIC YELLOW.
SLAB-ON-GRADE
(2) #3 x
AROUND DROP-IN ANCHORS
3/16"
6" STANDARD GALVANIZED STEEL PIPE
WITH 1/4" CAP PLATE, SET PLUMB
9" x 9" x 1/2" GALVANIZED STEEL PLATE
WITH ANCHORS @ 6 1/2" ON CENTER
1/4" NEOPRENE PAD
3/16"
GRIND SMOOTH
(4) 3/4"ø HILTI HDI DROP IN
ANCHORS AND BOLTS
(STAINLESS)
SEALANT ALL AROUND
2'-0" MIN
1'-6" MIN
M A
X
M
IN
M
IN
9" MIN
G R
A D
E B
E A
M /F
O O
T
IN
G
N O
P
IP
E T
O B
E P
L A
C E
D W
IT
H
IN
CONCRETE FILL TO BE PLACED
BEFORE GRADE
BEAM/FOOTING IS POURED.
MAKE SAME WIDTH AS GRADE
BEAM/FOOTING & FULL WIDTH
OF PIPE TRENCH.
ALL PIPES TO CLEAR SLEEVES
BY 1" SEALANT ALL AROUND
NO DIGGING FOR PIPE TRENCH
PARALLEL TO FOOTING WITHIN
THESE LINES
SLEEVE
PIPE
STEP FOOTING WHERE PIPES
ARE MORE THAN 2'-6" BELOW
BOTTOM OF FOOTING
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-510
SLAB ON GRADE / FOUNDATION DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
F7
SLAB CONSTRUCTION JOINT
DETAIL
D7
SLAB CONTROL JOINT DETAIL
C7
EDGE OF SLAB DETAIL AT
ASPHALT PAVING
F5
SLAB ON GRADE/COLUMN DETAIL
D5
FLOOR DRAIN AT SLAB ON GRADE
DETAIL
A7
EDGE OF SLAB DETAIL AT CIP
CONCRETE
C5
PIPE BOLLARD DETAIL (SLAB ON
GRADE)
D3
GRADE BEAM DETAIL
3/4" = 1'-0"F1
PIPE AT CONCRETE
FOOTING/GRADE BEAM DETAIL
A5
EDGE OF SLAB DETAIL
E7
WASH DETAIL
F3
COLUMN COVER
D1
FOUNDATION WALL DETAIL
B3
REMOVABLE PIPE BOLLARD
B1
REMOVABLE PIPE BOLLARD
D E
P T
H
C L E
A R
2"2"
5'-0"
5'-0"
C L E
A R
GRADE BEAM STEP LOCATION
CLASS B LAP SPLICE, BAR MAY
BE CONTINUOUS AT GENERAL
CONTRACTOR OPTION
CIP DRILLED PIER
TIES, SEE GRADE BEAM
SCHEDULE ON FOUNDATION
PLAN
NOTES:
1. SEE GRADE BEAM SCHEDULE ON SHEET S-100 FOR DEPTH DIMENSIONS.
SAME NUMBER AND
SIZE AS GRADE BEAM
REINFORCEMENT
BEAM TIES @ 12" ON CENTER
OVER DRILLED PIER
6"6"
2" RECESS
1'-0"
SHEAR
WALL
T.O. FOUNDATION
SEE PLAN
GRID
P/C SHEAR WALL
GROUT POCKET AFTER
CONNECTION IS COMPLETE
WITH NON-SHRINK NON-STAIN
GROUT
EMBED PLATE WITH ANCHORS. (2)
CONNECTIONS PER WALL (MINIMUM).
TO PREVENT ECCENTRIC HORIZONTAL
LOADING, CENTER CONNECTION IN WALL.
EMBED ANGLE
WITH ANCHORS
CONNECTION BY
PRECASTER, SEE
NOTE 1
WELD PLATES
NOTES:
1. WALL CONNECTIONS ARE PERFORMANCE DESIGN BY PRECASTER AND SHALL COMPLY
WITH ACI 318-11 SECTION 21.4 FOR INTERMEDIATE PRECAST STRUCTURAL WALLS.
2'-9" 2'-9"
C
D
EXISTING DRILLED
PIER CAP
EXISTING P/C
COLUMN
EXISTING DRILLED
PIER BELOW
NEW P/C COLUMN,
FIELD VERIFY LAYOUT
AND CONDITION OF
EXISTING ANCHOR
BOLTS
ETC = 727'-0" @ 9
ETC = 725'-6" @ 3
(FIELD VERIFY
EXISTING ELEVATIONS)
HORIZONTAL SLOTTED CONNECTION
BY PRECASTER TO ALLOW 1" MOVEMENT
EACH DIRECTION PARALLEL TO WALL
P/C WALL
C OF DPL
5'-0"
2'-2"
4" 2'-6"
3 1/2" 2 1/2"
1'-0"
11" 1"
C
10.9 11
D
EXISTING CIP
DRILLED PIER CAP
EXISTING P/C
COLUMN
EXISTING CIP
DRILLED PIER
BELOW, SEE PLAN
NEW P/C COLUMN,
FIELD VERIFY LAYOUT
AND CONDITION OF
EXISTING ANCHOR BOLTS
EXISTING CIP GRADE
BEAM, SEE PLAN
P/C WALL
ETC = 727'-0"
(FIELD VERIFY)
HORIZONTAL SLOTTED CONNECTION
BY PRECASTER TO ALLOW 1" MOVEMENT
EACH DIRECTION PARALLEL TO WALL
C D.P.L
C D.P.L
1"
JOINT
BACKER ROD
& SEALANT (2) CONNECTIONS
MINIMUM PER PANEL
NON-SHRINK
NON-STAIN GROUTP/C PANEL
CONTINUOUS
DAMPROOFING
1/4" MINIMUM PROTECTION
BOARD x 8" WIDE CENTERED
OVER JOINT
P/C PANEL
11"1"
4'-0" WASH
ETW
SEE PLAN
EBW
724'-0"
ETS
SEE PLAN
ETS
SEE PLAN
GRADE SLAB,
CAST TIGHT WITH
BOND BREAKER
3/4" DIAMETER x 2'-6"
COIL ROD AND INSERT
@ 18" O.C. WITH (2) #4 x
CONT. (OMIT AT SIM)
P/C WALL, SEE A8/S-511 FOR
CONNECTION TO COLUMN
AT LINE D. SEE F1/S-512 (SIM)
FOR CONNECTION TO CAP AT LINE E
SNOW DUMP AREA
GRADE SLAB
(NORMAL GRADE
SLAB AT SIM)
SLOPE
1/2"
COVE SEALANT,
SEE B5/S-502
6"6"3'-6" WASH 3'-6" WASH
2"
1'-0"
SHEAR
WALL
ETGB
SEE PLAN
ETS
SEE PLAN
G
F
SLAB ON GRADE, CAST
TIGHT WITH BOND
BREAKER. AT C4 SIM:
PROVIDE ASPHALT, SEE CIVIL
P/C SHEAR WALL, SEE
SHEET S-321
SLAB ON GRADE, CAST TIGHT
WITH BOND BREAKER
CIP GRADE BEAM,
SEE SCHEDULE ON
FOUNDATION PLAN
CIP DRILLED PIER,
SEE SCHEDULE ON
FOUNDATION PLAN
BASE CONNECTION,
SEE DETAIL F6/S-511
5'-0"
2'-2"
4"2'-6"
3 1/2"2 1/2"
1'-0"
11"1"
1.1
C
D
EXISTING CIP
DRILLED PIER CAP
EXISTING P/C
COLUMN
EXISTING CIP
DRILLED PIER
BELOW, SEE PLAN
NEW P/C COLUMN,
FIELD VERIFY LAYOUT
AND CONDITION OF
EXISTING ANCHOR BOLTS
EXISTING CIP GRADE
BEAM, SEE PLAN
ETC = 721'-0"
(FIELD VERIFY)
CIP FOOTING,
SEE D1/S-512
DRILL AND EPOXY (3) #5 x 2'-6" LONG
@ 12" OC TOP AND BOTTOM. PROVIDE 6"
EMBED INTO EXISTING DRILLED PIER CAP
WITH HILTI HIT-RE 500
HORIZONTAL SLOTTED CONNECTION
BY PRECASTER TO ALLOW 1" MOVEMENT
EACH DIRECTION PARALLEL TO WALL
C D.P.L
C D.P.L
1'-0"
6"
ETGB
SEE PLAN
ETS
SEE PLAN
CIP GRADE BEAM,
SEE SCHEDULE ON
FOUNDATION PLAN
CIP DRILLED PIER,
SEE SCHEDULE ON
FOUNDATION PLAN
SLAB ON GRADE,
CAST TIGHT
P/C SHEAR WALL
BASE CONNECTION TO CONSIDER
SOIL LOAD, SEE DETAIL F6/S-511
PERIMETER DRAINAGE
SYSTEM, BY OTHERS,
SEE SPECIFICATIONS
EXTERIOR GRADE,
SEE CIVIL
COVE SEALANT,
SEE B5/S-502
3/4"ø x 2'-6" COIL ROD
AND INSERT
@ 18" O.C. WITH (2) #4 x
CONT.
C DRILLED
PIER/GRADE BEAM
L
11" 1"
1 1/2"
1 1/2"
1"
ETGB
727'-0"
ETS
SEE PLAN
ETS
SEE PLAN
C
E
EXISTING CIP GRADE BEAM
EXISTING P/C WALL
EXISTING PERIMETER
DRAINAGE, DO NOT
DISTURB
CAST TIGHT WITH
BOND BREAKER
THICKENED SLAB EDGE,
SEE A7/S-510 SIM
8" THICK SLAB ON GRADE,
SEE NOTE 15, SHEET S-101
TOOLED JOINT WITH
SEALANT
PLACE BAR IN DOWEL
SLEEVE IN 5" THICK SLAB
ON GRADE
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-511
FOUNDATION DETAILS / SECTIONS
INCLUDING SLAB ON GROUND DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
D6
GRADE BEAM STEP DETAIL
F6
SHEAR WALL BASE CONNECTION
DETAIL
A8
PIER CAP DETAIL
E8
PIER CAP DETAIL
F8
VERTICAL PANEL CONNECTION
B6
FOUNDATION WALL DETAIL
C4
SHEAR WALL FOUNDATION DETAIL
F4
PIER CAP DETAIL
C1
SHEAR WALL FOUNDATION DETAIL
F1
EXTERIOR FOUNDATION WALL
EQUAL
LENGTH
(SEE DRILLED
PIER CAP SCHEDULE)
EQUAL
W
ID
T H
(S E
E D
R
IL
L E
D P
IE
R
C A
P S
C H
E D
U L E
)E Q
U A
L E
Q U
A L
LC DRILLED PIER
LC DRILLED
PIER
(4) #4 OR USE
LONGITUDINAL
REINFORCING
(SEE DRILLED
PIER CAP SCHEDULE)
LONGITUDINAL
REINFORCING (SEE
DRILLED PIER CAP
SCHEDULE)
BASE PLATE AND ANCHOR
BOLTS ABOVE,
CONFIGURATION VARIES.
COORDINATE LOCATION(S)
WITH P/C SUPPLIER
HORIZONTAL
REINFORCING (SEE
DRILLED PIER CAP
SCHEDULE)
2" CLEAR TYPICAL
CIP DRILLED PIER
BELOW
TRANSVERSE
REINFORCING (SEE
DRILLED PIER CAP
SCHEDULE)
CIP DRILLED PIER CAP
1/2 INITIAL STIRRUP
SPACING
STIRRUPS
AT
INITIAL
SPACING
STIRRUPS AT REMAINDER
SPACING
STIRRUPS
AT
INITIAL
SPACING
1/2 INITIAL STIRRUP
SPACING
2" CLEAR
NOTE 4NOTE 3
EQUALEQUAL
C L E
A R
T O
S T
IR
R
U P
NOTES:
1. PROVIDE CONTINUOUS BOTTOM REINFORCEMENT OR PROVIDE CLASS B LAP SPLICE OVER SUPPORT.
2. WHERE NO DRILLED PIER CAP IS PRESENT, PROVIDE GRADE BEAM STIRRUPS OVER DRILLED PIER AT
12" ON CENTER SPACING.
3. PROVIDE CONTINUOUS TOP REINFORCING OR PROVIDE CLASS B LAP SPLICE AT MID-SPAN.
4. DEVELOP TOP AND BOTTOM AND SIDE REINFORCEMENT INTO SUPPORT. PROVIDE 90° HOOK.
5. SEE DRAWING S-691 FOR SPLICE LENGTH AND DEVELOPMENT LENGTH REQUIREMENTS.
CIP GRADE
BEAM
DRILLED PIER, TYPICAL
PROVIDE 2 1/2"
MINIMUM SIDE
CLEARANCE
FOR HOOKS,
TYPICAL
STIRRUPS
MID-SPAN
EDGE OF
SUPPORT
EDGE OF
SUPPORT
CONTINUOUS
END CONDITION
DISCONTINUOUS
END CONDITION
NOTE 2
TOP LONGITUDINAL
REINFORCING
BOTTOM LONGITUDINAL
REINFORCING
NOTE 2
NOTE 1
SIDE
REINFORCING
WIDTH
D E
P T
H STIRRUPS
2" CLEAR
TYPICAL
C L E
A R
ALTERNATE LOCATION
OF 90° TIE-CAP HOOK
SEE PLAN
MATCH TOP ADJACENT
DRILLED PIER CAP UNO
BOTTOM REINFORCING
TOP REINFORCING
HORIZONTAL REINFORCING
AT EQUAL SPACING EACH
FACE
ALTERNATIVE STIRRUP
2'-0"
11"1'-0"
M
IN
T O
B O
T T
O M
O F
P A
N E
L B
E T
W E
E N
D R
IL
L E
D P
IE
R
C A
P S
1"
ETC
SEE PLAN
ETW
SEE PLAN
ETS
SEE PLAN
GRID
P/C WALL
PANEL
P/C COLUMN
HORIZONTALLY SLOTTED CONNECTION
BY PRECASTER TO ALLOW 1" MOVEMENT
EACH DIRECTION PARALLEL TO WALL
WALL PANEL BETWEEN
DRILLED PIER CAPS
DRILLED PIER CAP
GRADE SLAB.
CAST TIGHT WITH
BOND BREAKER.
PERIMETER DRAINAGE SYSTEM,
BY OTHERS, SEE SPECIFICATIONS
ROUTE AROUND PIER CAP AS
NECESSARY
SLOPE
1/2"
COVE SEALANT,
SEE B5/S-502
CONNECTION TO CAP
PERFORMANCE DESIGN
BY PRECASTER
AT LINE 1 ONLY,
3/4"ø x 2'-6" COIL ROD AND INSERT @ 4'-0" O.C. WITH (2) #4 x CONT
11" 1"
EQUAL EQUAL
ETW
SEE PLAN
ETS
SEE PLAN
1110.9
P/C WALL
PANEL
ETGB
SEE PLAN
CONNECTION PERFORMANCE
DESIGN BY PRECASTER
CIP GRADE BEAM,
SEE SCHEDULE
COVE SEALANT, SEE
B5/S-502
GRADE SLAB. CAST
TIGHT WITH BOND
BREAKER
PERIMETER DRAINAGE
SYSTEM, BY OTHERS,
SEE SPECIFICATIONS
SLOPE
1/2"
6"
11"1"
4"
4'-4"
G A
P
ETF
SEE PLAN
ETW
SEE PLAN
ETS
SEE PLAN
S-511
F8
P/C WALL. BRACE WALL
UNTIL GRADE SLAB
IS CAST AND ATTAINS
SPECIFIED STRENGTH.
CONNECTION PERFORMANCE
DESIGN BY PRECASTER
GRADE SLAB,
CAST TIGHT
CIP FOOTING WITH #5 @ 12" OC EW
TOP AND BOTTOM WITH STANDARD
HOOKS, DOWEL REINFORCING
INTO INTERSECTING DRILLED PIER
CAP AT E/1 . DRILL AND EPOXY
(3) #5 x 2'-6" LONG TOP AND BOTTOM
PER DETAIL F4/S-511 AT D/1.
3/4" DIAMETER x 2'-6"
COIL ROD AND INSERT
@ 18" O.C. WITH (2) #4 x
CONT.
COVE SEALANT,
SEE B5/S-502
PERIMETER DRAINAGE
SYSTEM, BY OTHERS,
SEE SPECIFICATIONS
P/C INFILL WALL
P/C SPANDREL
ABOVE
2 HR FIRE RATED
JOINT ALL AROUND.
SEE SPECIFICATIONS
DAMPPROOFING
AS
NEEDED
2'-0"
11"
T.O. FOUNDATION
SEE FOUNDATION PLAN
ETW
SEE PLAN
ETS
SEE PLAN
ETS
SEE PLAN
CAST-IN-PLACE
FOOTING
(2) # 5 x CONTINUOUS
EXTEND 1'-6" INTO
INTERSECTING
FOUNDATION
GRADE SLAB,
CAST TIGHT
WITH BOND
BREAKER
CONNECTION PERFORMANCE
DESIGN BY PRECASTER
P/C WALL PANEL
NO GRADE SLAB
PRESENT AT "SIM"
AT WALLS OF SNOW DUMP AREAS ONLY,
OMIT BOND BREAKER AND PROVIDE
3/4"ø x 2'-6" COIL ROD AND INSERT @ 18" O.C. WITH (2) #4 x CONT
PROVIDE WASH WHERE
SHOWN ON PLAN
SLOPE
1/2"
COVE SEALANT,
SEE B5/S-502
2'-0"
8"1'-0"
M
IN
T O
B O
T T
O M
O F
P A
N E
L B
E T
W E
E N
D R
IL
L E
D P
IE
R
C A
P S
4"
4'-0"
11" 1"
ETS
SEE PLAN
E
C
P/C WALL
PANEL
P/C COLUMN
ETC
SEE PLAN
WALL PANEL BETWEEN
DRILLED PIER CAPS
DRILLED PIER CAP
ETW = 730'-6"
GRADE SLAB
AREA DRAIN,
SEE D6/S-510
PROVIDE 1/2"
JOINT FILLER
AROUND COLUMN
CONNECTION TO CAP PERFORMANCE
DESIGN BY PRECASTER
COVE SEALANT BOTH SIDES,
SEE B5/S-502
SLOPE
1/2"
CAST TIGHT TO P/C WALL
BOTH SIDES WITH BOND
BREAKER
EXISTING CIP WALL
AND GRADE BEAM
TOOLED JOINT
W/ SEALANT
CAST TIGHT
WITH BOND
BREAKER
6"
11"1"
3"
4" 4'-0"
G A
P
ETGB
SEE PLAN
ETW
SEE PLAN
ETS
SEE PLAN
S-511
F8
P/C WALL. BRACE WALL
UNTIL GRADE SLAB
IS CAST AND ATTAINS
SPECIFIED STRENGTH.
CONNECTION PERFORMANCE
DESIGN BY PRECASTER
GRADE SLAB,
CAST TIGHT
CIP FOOTING EXTENSION WITH
#5 @ 12" O.C. E.W. TOP AND
BOTTOM WITH STANDARD HOOKS
INTO GRADE BEAM, DOWEL
REINFORCING
INTO INTERSECTING DRILLED PIER
CAPS x 2'-0"
3/4" DIAMETER x 2'-6"
COIL ROD AND INSERT
@ 18" O.C. WITH (2) #4 x
CONT.
COVE SEALANT,
SEE B5/S-502
PERIMETER DRAINAGE
SYSTEM, BY OTHERS,
SEE SPECIFICATIONS
P/C INFILL WALL
P/C SPANDREL
ABOVE
2 HR FIRE RATED
JOINT ALL AROUND.
SEE SPECIFICATIONS
DAMPPROOFING
AS
NEEDED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-512
FOUNDATION DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
D8
DRILLED PIER CAP PLAN
B8
GRADE BEAM DETAIL
F8
GRADE BEAM SECTION DETAIL
F5
EXTERIOR FOUNDATION WALL
F3
GRADE BEAM WALL DETAIL
D1
EXTERIOR FOUNDATION WALL
DETAIL
D5
FOUNDATION WALL
F1
FOUNDATION WALL
D3
EXTERIOR FOUNDATION WALL
DETAIL
P/C COLUMN
3 SIDES
TOP OF
P/C BEAM
TOP OF
P/C BEAM
2'-0"
/2
C L E
A R
M A
X
IM
U M
T Y
P
W H
E R
E N
O T
E D
8" 8"
CONTINUOUS BOTTOM REINFORCING
1" CLEAR IN LEDGE MAXIMUM
CONTINUOUS HORIZONTAL REINFORCING
CONTINUOUS TOP REINFORCING
(4) #4 AT 3" EACH TEE
STEM MINIMUM, AT 10" MAXIMUM
SPACING BETWEEN STEMS
(2) #5 x CONTINUOUS TYPICAL
MINIMUM (PROVIDE STANDARD
HOOK OR U-BAR AT ENDS)
NOTES:
EQUIVALENT PREFABRICATED WWR ACCEPTABLE
(2) #4 MINIMUM BY P/C SUPPLIER
TIED TO STIRRUPS AT 16" ON
CENTER MAXIMUM SPACING (EPOXY COAT)
/4
1'-0"
8"
SEE DETAIL C1/S-520
CONTINUOUS BOTTOM REINFORCING
CONTINUOUS HORIZONTAL REINFORCING
CONTINUOUS TOP REINFORCING
SEE DETAIL C1/S-520 FOR
LEDGE DETAILS AND
REINFORCING
NOTES:
EQUIVALENT PREFABRICATED WWR ACCEPTABLE
2"
D A
P
D E
P T
H
2'-6"
(1) #4 x (MINIMUM)
STIRRUPS
MINIMUM 1"
CLEAR END
OF BAR
Av
EDGE OF BEAM
BEARING PLATE
NOTES:
1. EQUIVALENT PREFABRICATED WWR ACCEPTABLE.
2. WELD Av AND As TO BEARING PLATE TO DEVELOP BARS.
As
BOTTOM
REINFORCEMENT
6"
2"
2'-6"
(1) #4 x (MINIMUM)
STIRRUPS
15°
MINIMUM 1"
CLEAR END
OF BAR
Avf
Av
EDGE OF BEAM
BEARING PLATE
NOTES:
1. EQUIVALENT PREFABRICATED WWR ACCEPTABLE.
2. WELD Av AND Avf TO BEARING PLATE TO DEVELOP BARS.
6"
/2
C L R
/2
C L R
75°T Y P
A S
R E
Q U
IR
E
D
/4
3/4"
TYP
TEE STEM
WIDTH +2
TYPICAL POCKET
1'-2"
P/C BEAM
1'-2"
(2) #6 AT EACH POCKET.
SPACED 1" APART,
CENTERED AT TEE
BEARING
(2) #3 AT EACH
POCKET. SPACED 1"
APART, CENTERED AT
TEE BEARING
#4 HAIRPIN
WITH 2'-0"
LEGS
SLOTTED INSERT. SEE
C1/S-521
TAPERED EDGES
B
D
CONT BOT REINF
CONT TOP REINF
CONT HORIZ REINF TYP
NOTE:
EQUIVALENT
PREFABRICATED WWR
ACCEPTABLE
POCKETED BEAM AS
REQ'D - SEE DETAILS.
POCKETED BEAMS
SHALL BE
PRESTRESSED TO 150
PSI MIN
COMPLETE CONNECTION BEFORE TEE ERECTION.
FACE OF P/C BEAM
P/C COLUMN
1/2" PAD W/ HOLE
GLUE TO BEAM
CONNECTOR SLEEVE
AND CLOSURE CAP BY
HIGH CONCRETE
ACCESSORIES SEE
SPECIFICATIONS
PROVIDE GALV PLATE
WASHER W/ GALV NUT IN
POCKET & PEEN THREADS
1" MIN DIAMETER GALV COIL
ROD INTO GALV INSERT IN
BEAM. PROVIDE (2) #3
HAIRPINS W/ LEGS AROUND
INSERT.
NOTE:
2'-0"
NOTE:
1. COMPLETE CONNECTION BEFORE TEE ERECTION.
2. CAUTION, THIS DETAIL REQUIRES CAREFUL ATTENTION TO ERECTION TOLERANCE.
CONSIDER USING SLOTTED INSERT AS REQUIRED.
1" MIN DIA GALV COIL ROD INTO
GALV INSERT IN COLUMN
PROVIDE (2) #3 HAIRPINS W/
LEGS AROUND INSERT
1/2" PAD W/ HOLE
GLUE TO COLUMN
PROVIDE GALV PLATE
WASHER W/ GALV NUT IN
POCKET & PEEN THREADS
CONNECTOR SLEEVE
AND CLOSURE CAP BY
HIGH CONCRETE
ACCESSORIES SEE
SPECIFICATIONS
FACE OF P/C COLUMN
P/C
BEAM
2'-0" x x x x x x
CIP TOPPING
P/C SPANDREL
P/C TEE
L BRACE AS NEEDED NEAR
SHEARWALL TO RESIST BUMPER
LOAD/TORSION. PERFORMANCE
DESIGN BY PRECASTER
NOTE:
SEE DETAIL B3/S-522 FOR REMAINING
INFORMATION
1. REFER TO SHEET S-001 FOR GENERAL NOTES.
2. BEAM DESIGN IS PERFORMANCE DESIGN AND SHALL
INCLUDE TYPE, NUMBER, AND LOCATION OF STRANDS
AND/OR CONVENTIONAL REINFORCEMENT AS WELL AS
LEDGE, SHEAR/TORSION AND END OF BEAM
REINFORCEMENT. DESIGN SHALL ALSO INCLUDE ALL
BEAM TO COLUMN (OR OTHER SUPPORT) CONNECTIONS.
SEE SPECIFICATION SECTION 03 41 00 FOR PRECAST
CONCRETE.
3. APPLY MASTIC TO EACH STRAND AT ENDS OF BEAM.
4. FOR MEMBER SIZES AND OTHER INFORMATION SEE
STRUCTURAL AND ARCHITECTURAL DETAILS.
5. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ANY REQUIRED PENETRATIONS.
6. FOR EMBEDDED PLATES TO RECEIVE WELDS AS PART
OF WELDED CONNECTIONS SEE DETAIL B8/S-523.
7. FOR SEALANT REQUIREMENTS AT BEAM/COLUMN
INTERFACES SEE DETAILS B7, F3, AND F7/S-502.
8. WHERE OPENINGS ARE REQUIRED, PROVIDE OPENINGS
AT APPROXIMATELY MID-DEPTH OF STEMS OF INVERTED
TEE (DOUBLE LEDGER) BEAMS. PLACE NO CLOSER THAN
5'-0" FROM END OF BEAM. COORDINATE SIZE AND
LOCATION REQUIREMENTS WITH MECHANICAL AND
ELECTRICAL.
9. REFER TO GENERAL NOTE III-C-10 ON SHEET S-001 FOR
CORROSION PROTECTION.
A3
BEAM TOP CONNECTION DETAIL
C1
BEAM TYPE C DETAIL
A1
BEAM TYPE D DETAIL
C3
END OF BEAM REINFORCMENT
DETAIL (DAPPED BEAM)
E3
END OF BEAM REINFORCMENT
DETAIL (UNDAPPED BEAM)
GENERAL SHEET NOTES
A5
P/C BEAM DETAIL
E1
BEAM TYPE B DETAIL
C5
CONNECTION DETAIL
E5
CONNECTION DETAIL
A7
PANEL BRACE DETAIL
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
07/08/16
S-520
PRECAST BEAM DETAILS
EXPAND PARKING GARAGE 589-401
RES MAP
24" SQUARE
2"
1'-0"1'-0"
1" 1"
2"
1'-4" LAP
/2
"TEE FLANGE
AT WASHLINE
TIE REBAR AT CROSSINGS
TEE STEM
CONCRETE
TOPPING
(2) #4 (EPOXY) EACH WAY
BY GENERAL CONTRACTOR
- PLACE TIGHT TO SIDES OF
DRAIN
28" SQUARE BY 3" DEEP
CAST-IN-PLACE CONCRETE WITH
INTEGRAL CAST-IN DRAIN -
DRAIN BY PLUMBING
CONTRACTOR
TEE FLANGE
#4 (EPOXY)
PERIMETER
BARS
3/8" x 3/8" GAP
FORMED ALL
AROUND DRAIN,
FILL WITH
SEALANT
2"2"
2" Ah (1) #4 U-BAR x
2'-0" (MINIMUM)
As WELDED TO
PLATE TO DEVELOP
BAR
SHEAR REINFORCING
5'-0" MINIMUM STEM
MESH EACH STEM -
EACH END, BUT NOT
LESS THAN REQUIRED
BY DESIGN
Av WELDED TO PLATE
BEARING PLATE
MINIMUM 1"
CLEAR END
OF BAR
Ash
2"
6"
Av WELDED TO PLATE
15°
WELD BAR TO PLATE
TO DEVELOP BAR
MINIMUM 1"
CLEAR END
OF BAR
SHEAR REINFORCING
5'-0" MINIMUM STEM
MESH EACH STEM -
EACH END, BUT NOT
LESS THAN
REQUIRED BY
DESIGN
BEARING PLATE
AvF
1/4"±
XX XX XX
P/C TEE
CONTINUOUS TOOLED JOINT (SAWCUT
JOINT PROHIBITED) IN TOPPING
DIRECTLY ABOVE INTERSECTION OF
TEE FLANGES. JOINT SEALED WITH
CONTINUOUS SEALANT. SEE DETAIL
F5/S-502.
4" MAXIMUM WIDE x CONTINUOUS
STRIP OF BURLAP SOAKED IN
CEMENTITIOUS SLURRY OVER
TEE/TEE JOINT
4" LONG STAINLESS STEEL BAR
P/C ERECTOR TO PROVIDE VARIOUS
SIZES TO FIT ERECTION TOLERANCES
STAINLESS STEEL
JVI VECTOR CONNECTOR
OR APPROVED EQUAL FLANGE
CONNECTOR AT 4'-0" O.C.
CAST-IN-PLACE CONCRETE
TOPPING
NOTES:
1. RECOMMEND USING GMAW PROCEDURES TO REDUCE SLAG.
2. TO ALLEVIATE CRACKING, CONSIDER USING SMALLER WELD PASSES.
3. OBSERVATION AND VERIFICATION OF WELDING PROCEDURES BY A TESTING AGENCY IS
RECOMMENDED, PARTICULARLY FOR INITIAL INSTALLATION OF TEE/TEE CONNECTIONS.
4. 4" MAXIMUM WELD LENGTH, DO NOT OVER WELD
4, SEE 1/4
E 308
ELECTRODES
NOTE 4
S E
E D
E T
A
IL
S
3/4" CLEAR
WASH
SEE DETAILS
/4
C
L R
/2
ETS
SEE PLAN
x x x x x x x x x x
WWR
P/C TEE
P/C BEAM OR COLUMN
COVE SEALANT, SEE DETAIL B5/S-502
CAST-IN-PLACE
CONCRETE TOPPING
CONCRETE DAM BY
GENERAL CONTRACTOR
SLOTTED INSERT AND WELD PLATES
OR ENGINEER APPROVED EQUIVALENT
PERFORMANCE DESIGN BY PRECASTER.
LOCATE AT 4'-0" ON CENTER AT NON-LOAD
BEARING BEAMS AND AT EACH TEE STEM
AT LOAD-BEARING BEAMS.
(2) #4 x CONTINUOUS
(MINIMUM). OMIT
BOTTOM BAR AT
POCKETED SPANDRELS
AND PROVIDE HAIRPIN
PER A5/S-520
CHORD STEEL @ 3" OC,
SEE PLAN. PLACE BARS 6"
MINIMUM FROM FACE
OF BEAMS TO ALLOW
FOR CORE DRILLING
OF CONDUIT.
E Q
U A
L
AS REQUIRED
6'-0"
AS REQUIRED
3'-0" 3'-0"
15'-0" 15'-0"
PLAN VIEW AT BLOCKOUT
C
DAP BEARING AS
#4 REBAR AT
FLANGE
MID-DEPTH
AT MINIMUM, PROVIDE 3" x 5 3/4" DOUBLE TEE STEM
BLOCKOUTS AT 1_
POINTS. ALSO SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL LOCATIONS
CGS
CGS
REQUIRED, SEE
L
TEE ELEVATION
TEE END VIEW
APPLY MASTIC TO
STRAND AT ENDS
OF ALL TEES
NOTES:
1. SEE SPECIFICATIONS FOR FINISH.
WWR AT FLANGE MID-DEPTH
DETAIL A3/S-521
TRANSVERSE RAKE FINISH 1_
DEPTH MINIMUM TO ENSURE
BOND OF TOPPING
1. REFER TO SHEET S-001 FOR GENERAL NOTES.
2. TEE DESIGN IS PERFORMANCE DESIGN AND SHALL
INCLUDE TYPE, NUMBER AND LOCATION OF STRANDS
AS WELL AS SHEAR, FLANGE AND END OF TEE
REINFORCEMENT. SEE SPECIFICATION SECTION 03 41 00
FOR PRECAST CONCRETE.
3. MINIMUM CIP TOPPING REINFORCEMENT SHALL BE AS
FOLLOWS:
3" CIP TOPPING: WWR 4x4 - W4xW4
a. PLACE REINFORCEMENT AT MID-DEPTH OF
FLANGE OR TOPPING.
b. PROVIDE TOPPING WWR IN SHEETS NOT
ROLLS.
c. SUPPORT TOPPING WWR WITH CONTINUOUS
BAR SUPPORTS SPACED @ 2'-0" ON CENTER
MAXIMUM.
4. FOR TEE/TEE JOINT DETAIL SEE DETAIL E1/S-521.
5. FOR EMBEDDED PLATES TO RECEIVE WELDS AS PART
OF WELDED CONNECTIONS SEE DETAIL B8/S-523.
6. REFER TO GENERAL NOTE III-C-10 ON SHEET S-001 FOR
CORROSION PROTECTION.
B1
DRAIN INSTALLATION DETAIL
A3
END OF TEE REINFORCEMENT
(DAPPED TEE)
B3
END OF TEE REINFORCEMENT
(UNDAPPED TEE)
E1
TEE/TEE JOINT DETAIL
C1
TOPPING DETAIL
E3
TYPICAL P/C TEE DETAIL
GENERAL SHEET NOTES
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.