About this file

36C25218B0935 0003 S06 A0003_Att1 DWG NP2-2.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 676-18-201 Build Whole Health Complex Tomah VA Medical Center - Tomah, WI, newest first.
File Type Posted
36C25218B0935-048.docx DOCX document
36C25218B0935-0006000.docx DOCX document
36C25218B0935-0005000.docx DOCX document
36C25218B0935-0004000.docx DOCX document
36C25218B0935-0003000.docx DOCX document
36C25218B0935-0003002.pdf PDF
36C25218B0935-0002000.docx DOCX document
36C25218B0935-0002002.pdf PDF
36C25218B0935-0002003.pdf PDF
36C25218B0935-0002001.pdf PDF
36C25218B0935-0001002.pdf PDF
36C25218B0935-0001000.docx DOCX document
36C25218B0935-0001001.pdf PDF
36C25218B0935-045.pdf PDF
36C25218B0935-041.pdf PDF
36C25218B0935-042.pdf PDF
36C25218B0935-043.pdf PDF
36C25218B0935-046.pdf PDF
36C25218B0935-040.docx DOCX document
36C25218B0935-047.pdf PDF
36C25218B0935-044.pdf PDF
36C25218B0935-000.docx DOCX document
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A B C A B C

SPACE --- --- 1P 1 2 2P-30 2.88 --- ---

SPACE --- --- 1P 3 4 --- 2.88 ---

SPACE --- --- 1P 5 6 2P-30 --- --- 2.88

SPACE --- --- 1P 7 8 2.88 --- ---

SPACE --- --- 1P 9 10 2P-30 --- 2.88 ---

SPACE --- --- 1P 11 12 --- --- 2.88

SPACE --- --- 1P 13 14 2P-30 2.88 --- ---

SPACE --- --- 1P 15 16 --- 2.88 ---

EXISTING LOAD --- --- 2.00 1P-30 17 18 1P-30 --- --- 2.00

EXISTING LOAD 2.00 --- --- 1P-30 19 20 1P-30 2.00 --- ---

EXISTING LOAD --- 2.00 --- 1P-30 21 22 1P-30 --- 2.00 ---

EXISTING LOAD --- --- 2.00 1P-30 23 24 1P-30 --- --- 2.00

EXISTING LOAD 2.00 --- --- 1P-30 25 26 1P-30 2.00 --- ---

EXISTING LOAD --- 2.00 --- 1P-30 27 28 1P-30 --- 2.00 ---

EXISTING LOAD (GFI) --- --- 2.00 1P-30* 29 30 1P-20 --- --- 1.00

EXISTING LOAD 1.00 --- --- 1P-20 31 32 1P-20 1.00 --- ---

EXISTING LOAD --- 1.00 --- 1P-20 33 34 1P-20 --- 1.00 ---

EXISTING LOAD --- --- 1.00 1P-20 35 36 1P-20 --- --- 1.00

EXISTING LOAD 1.00 --- --- 1P-20 37 38 1P-20 1.00 --- ---

EXISTING LOAD --- 1.00 --- 1P-20 39 40 1P-20 --- 1.00 ---

EXISTING LOAD (GFI) --- --- 1.00 1P-20* 41 42 1P-20 --- --- 1.00

SUB TOTAL 6.00 6.00 8.00 14.64 14.64 12.76

20.64 20.64 20.76

C/B TEMP. 75 C. RATING 120 208

A B C A B C

ISOLATED GROUND BUS YES X NO 0.00 0.00 0.00 125% 0.00 0.00 0.00

MAIN CIRCUIT BREAKER X YES NO <=10 KVA@100% 3.33 3.33 3.33

SERVICE ENTR. RATED YES X NO >10KVA@50% 8.66 8.66 8.72

MINIMUM AIC (K AMPS) 10 LARGEST 0.00 0.00 0.00 125% 0.00 0.00 0.00

MCB 225A ALL OTHERS 0.00 0.00 0.00 100% 0.00 0.00 0.00

BUS RATING 400A 0.00 0.00 0.00 125% 0.00 0.00 0.00

NEUTRAL RATING 100% 0.00 0.00 0.00 100% 0.00 0.00 0.00

0.00 0.00 0.00 100% 0.00 0.00 0.00

0.00 0.00 0.00 125% 0.00 0.00 0.00

TOTAL KVA PER PHASE 20.64 20.64 20.76 11.99 11.99 12.05

100 100 100

36.02

LOAD SERVED

KVA / Phase CKT

BRKR

CKT

NO

NEUTRAL

A B C

CKT

NO

CKT

BRKR

KVA / Phase

LOAD SERVED

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

SUB TOTAL

TOTAL

V 3 PH 4 WIRE

LOAD TYPE

CONNECTED KVA NEC DEM

FACTOR

DEMAND KVA

PANEL / FEEDER (TOTAL KVA)

MOUNTING SURFACE

GENERAL LIGHTING

GENERAL USE

RECEPT

20.64 20.64 20.76

NP2-2

(TOTAL KVA) X 1000 = TOTAL AMPS

VOLTS X 1.732

MOTORS AND

EQUIPMENT

WATER HEATERS

FIX. ELEC. SPACE HEAT

DEDICATED RECEPT

SIGN

NOTE: ALL MOTOR CIRCUIT BREAKERS SHALL BE HACR RATED.

*:(INDICATES) GFI BREAKER TOTAL DEMAND AMPERES PER PHASE

L:\Projects - Eng\2017 Projects\17-289-Nagel-VA Tomah Build Whole Health-WI\Design\Elec\Panel Schedules\panel scheduels 208V-3 Phase.xls 8/17/2018 1:25 PM