676-18-201 Build Whole Health Complex Tomah VA Medical Center - Tomah, WI Federal contract opportunity
Solicitation number
36C25218B0935
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

36C25218B0935 0002 36C25218B0935 0002.docx

View the file

Other files for this federal contract opportunity

Other files attached to 676-18-201 Build Whole Health Complex Tomah VA Medical Center - Tomah, WI, newest first.
File Type Posted
36C25218B0935-048.docx DOCX document
36C25218B0935-0006000.docx DOCX document
36C25218B0935-0005000.docx DOCX document
36C25218B0935-0004000.docx DOCX document
36C25218B0935-0003000.docx DOCX document
36C25218B0935-0003002.pdf PDF
36C25218B0935-0003001.pdf PDF
36C25218B0935-0002003.pdf PDF
36C25218B0935-0002002.pdf PDF
36C25218B0935-0002001.pdf PDF
36C25218B0935-0001000.docx DOCX document
36C25218B0935-0001001.pdf PDF
36C25218B0935-0001002.pdf PDF
36C25218B0935-042.pdf PDF
36C25218B0935-045.pdf PDF
36C25218B0935-041.pdf PDF
36C25218B0935-043.pdf PDF
36C25218B0935-046.pdf PDF
36C25218B0935-040.docx DOCX document
36C25218B0935-047.pdf PDF
36C25218B0935-044.pdf PDF
36C25218B0935-000.docx DOCX document
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE

OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

BY

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 08-16-2018 676-18-3-6919-0019 676-18-201 36C252 Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite 101 Milwaukee

WI

53214-1476 36C252 Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite 101 Milwaukee

WI

53214-1476 To all Offerors/Bidders

36C25218B0935 07-20-2018

X X X ** HOUR & DATE for Receipt of Offers is EXTENDED to:

Wed. August 22, 2018 at 12:30 p.m. CST

676-3680162-6919-854200-3220 23NR8MA45

X Amendment A00002 - see continuation page(s) and attachment(s) for specific details.

CONTINUATION PAGE

SOLICITATION 36C25218B0935

AMENDMENT 00002

08/16/2018

PROJECT:676-18-201 Build Whole Health
LOCATION:Tomah VA Medical Center in Tomah, WI

Amendment 00002 hereby incorporates the following change(s) into the solicitation package:

A.) VENDOR QUESTION 8/8/2018

1. Please clarify intent for fire suppression sprinkler piping. Division 21 specification states no plastic piping to be used. We suspect that the existing piping may be mostly plastic or deco-shield. I do not see anywhere that the documents call for demo of sprinkler piping other than where it may have to get re-piped for ceiling work.

VA REPLY: Sprinkler systems are not to be demolished. Both metal piping and plastic piping is present. The east wing contains some plastic piping and the central corridor is metal piping. Only the sprinkler heads will be affected during the project. The sprinkler heads shall be relocated (and height adjustment, as needed) at all new ceiling areas and & in rooms where walls are to be demolished in accordance with specifications. A00002 Attachment 1 provides general location of plastic and metal piping.

B.) VENDOR QUESTION(S), 8/9/2018

1. will the contractor be responsible for the demo work?

VA REPLY: Yes.

2. will waterproofing be needed on the floors of bathrooms?

VA REPLY: Yes – Per Specification Section 09 30 13, Para 2.5: Waterproof membrane is required.

3. Alternate #3 calls for wall tile on wet walls only. In bath#20790 women’s, are we to consider the sink and the toilet wall both to be wet walls or just the toilet wall?

VA REPLY: Both sink and toilet walls are considered wet walls.

C.) VENDOR QUESTION(S), 8/10/2018

1. In restrooms 20790 & 20788 the room finish schedule indicates new tile on the walls over the existing walls. In these restrooms the existing finish appears to be an existing tile. Nothing on the drawings is indicates the existing tile being demoed and the existing walls being repaired, or a new tile backer board being installed over the walls. The tile section indicates cement backer board for the new walls. Do you want cement board as the tile backer board for over the new walls?

VA REPLY: Demo existing tile, patch & repair existing wall/backer, install new tile as indicated on existing backer.

2. Is the existing substrate going to be demoed or is a tile backer going to be installed over the existing tile as a backer board for the new tile, or is there some other different going to be done? Demo tile. Existing substrate to remain (if possible). New tile on existing repaired backer.

VA REPLY: Demo tile. Existing substrate to remain (if possible). New tile on existing repaired backer.

3. In 20743A the existing walls have a tile wainscot which is being removed. Are the existing walls to be patched and the new tile to be installed over the existing walls or is a new backer to be applied to the existing walls that receive new tile which is called out in the room finish schedule?

VA REPLY: Existing wall to be patched and new tile to be installed over existing backer.

D.) VENDOR QUESTION(S) - 8/15/2018

1. After review of both prints and specs, I cannot find any key notes relating to demo of any doors. Ref Pg AD001, no key notes related to doors for demolition or removal. Please advise as to which doors will be replaced.

VA REPLY: AD001 has been modified to clarify which doors are being demolished (ref A00002, Attachment 2). This includes all corridor doors (near Corridor/7C23, 7C25 & 7C27), the doors to rooms 20739, 20743, 20743A, 20745, 20747, existing room 2748B, 20749, 20755, existing room 2752, chase north of 20761, 20762, 20762A, door between 20762 & 20742, 20763, 20765, 20766, 20769, 20770, interior to 20771, 20775, 20781, 20782, 20783, existing room 2785A, 20784, 20790, and 20799. Reference A00002 Attachment 2, Drawing AD001-rev.

2. Ref Spec section 08 11 13 Pg 3, Part 2 / 2.1 system performance: It calls out for 3 types of doors. Fire rated, smoke control and sound rated. Doors in the schedule are not called out for any of the 3 stated in the specs. Please indicate which doors receive if any, one of the 3 ratings. VA REPLY: There are no fire, smoke, or sound rated new doors to be installed.

3. Ref Pg AE202 detail B5 and D8: Details call out for “ceiling mounted partitions.” These types of partitions require fastening to ceiling joist with structure steel which in turn requires most of the ceiling be removed to access and install. In bathroom 20790, this would require removal of granite style header to be removed and trashed to allow for ceiling supports to be installed. We would recommend using a HDPE composite material mounting to floor with standard headrail as this would be a tremendous cost savings in labor and materials.

VA REPLY: Existing toilet partitions are ceiling mounted; design intent is to remove existing partitions and install new at same locations. Utilize existing ceiling supports to install new partitions.

4. Doors and frames: At the site walk, it was noted the frames are flush with the walls. The wall make-up appears to be plaster. To remove the existing door, a minimum of 4 inches around the entire frame, inside room and corridor side will need to be cut to remove door. Opening will need to be framed to accommodate new door. Drywall will be installed over new framing and flush to existing plaster wall. The issue with this is, regardless of materials used, a hairline crack will continuously form at the joint. To correct this, will the VA accept type of expansion joint (fry reglet) around perimeter of door to alleviate this issue?

VA REPLY: Fry reglet expansion joint is acceptable.

F. VENDOR QUESTION(S) – 8/16/2018

1. NP1-3 has breakers listed for heat trace. The Mechanical specs talk about freeze protection on Hydronic outdoor piping. Do the Breakers need to be GFCI for equipment? Is there a plan showing the connection points for the exterior hydronic piping that needs freeze protection?

VA REPLY: Notations in the panel schedule are reflections of the existing conditions and previous heat trace systems serviced from the panel. There is not a new heat trace systems or connections in this project. These are existing circuits and circuit designations.

G. VENDOR QUESTION(S) – 8/16/2018

1. Reference Demo page AD001: Walls showed “dashed” are to be demolished. Are the walls to be taken out complete to upper decking, or above existing ceiling height?

VA REPLY: Walls shall be fully demolished to the deck.

Also, attached is a copy of the most current Wisconsin, Monroe County Wage Rates (WI11, WI180011, 08/10/2018). These wage rates replace previously issued wage rates.

If there are any open, un-answered questions a contractor has submitted, please send a follow-up e-mail to Kristi.Kluck3@va.gov.

Contractors shall ensure all amendments are being acknowledged with their bid submission.

The date for the public bid opening is being EXTENDED by two days; bids are due no later than Wednesday, August 22, 2018 at 12:30 p.m. CST.

The location for the public bid opening has not changed; bid opening is being held at the Honey Creek Business Park - 115 S. 84th Street - Suite 101, Milwaukee, WI 53214-1476.

Attachments:

See attached document: S06 36C25218B0935 A002_Att1 SKETCH_Above Clg Piping.

See attached document: S06 36C25218B0935 A002_Att2 DWG AD001.Rev1.

See attached document: S06 36C25218B0935 A002_Att3 Wage Rates WI_2018.08.10 current as of 08.16.2018.

File details come from the government source that posted it.