This presolicitation notice announces an upcoming solicitation for demolition services. The Department of Veterans Affairs will issue an invitation for bid on or about January 31, 2020 via SAM.gov to solicit bids for the demolition and removal of buildings 35, 36, 37, 38, 75, 94, 95, 96, 118 and 149 at the VA Northern Indiana Health Care System campus in Marion, Indiana. The contractor will be responsible for asbestos/lead paint abatement, utility disconnection, demolition of all structures including foundations and footings, backfilling, grading and seeding. All items removed must be disposed of by the contractor. The project is set aside for a Service-Disabled Veteran-Owned Small Business and has an estimated value between $500,000 and $1,000,000.
36C25020B0017 0002 Marion Asbestos Survey.xlsx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25020B0017-0005000.docx | DOCX document | |
| 36C25020B0017-0004001.docx | DOCX document | |
| 36C25020B0017-0004000.docx | DOCX document | |
| 36C25020B0017-0003000.docx | DOCX document | |
| 36C25020B0017-0002001.pdf | ||
| 36C25020B0017-0002004.docx | DOCX document | |
| 36C25020B0017-0002003.pdf | ||
| 36C25020B0017-0002000.docx | DOCX document | |
| 36C25020B0017-0001000.docx | DOCX document | |
| 36C25020B0017-0001001.pdf | ||
| 36C25020B0017-012.txt | TXT text file | |
| 36C25020B0017-009.pdf | ||
| 36C25020B0017-010.doc | DOC document | |
| 36C25020B0017-007.docx | DOCX document | |
| 36C25020B0017-008.pdf | ||
| 36C25020B0017-011.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Explanation
| Explanation of Survey | ||
| Abreviation | Material Identified | |
| BT | Black Tar | |
| MCB | Mastic on Cove base | |
| FD | Fire Door | |
| ED | Elevator Doors | |
| ERT | Exterior Roof Tar | |
| EWC | Exterior Window Caulk | |
| IWC or IWG | Interior Window Caulk / Glazing | |
| FT | Floor Tile | |
| FT & MFT | Floor Tile & Mastic on Floor Tile | |
| MFT | Mastic on Floor tile | |
| PI | Pipe Insulation | |
| PJ | Pipe Joist | |
| DWC | Drywall Compund | |
| MCT | Mastic on Ceiling Tile |
Each tab at the bottom of this document is the survey for an individual building. Within each tab the room number and material identified is listed as seen below.
Bldg 1
| Room/Area | Material Description | Material Abbr. | Material Quantity | Unit of Measure | Comments | Condition | Method of Abatement | |
| 1st Floor | ||||||||
| 100 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 90 | SF | Mastic Associated w/ Floor Tile Positive and Fire Door Assumed on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Wrap & Remove | ||||
| 100A | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 32 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 1x1 White /Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | 32 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. Material not identified on Previous Report | Good | Contain & Remove | ||
| 101 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 170 | SF | Mastic Associated w/ Floor Tile Positive and Fire Door Assumed on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 102 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 144 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 103 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 120 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 104 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 130 | SF | Mastic Associated w/ Floor Tile Positive and Fire Door Assumed on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 105 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 80 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. Material not identified on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| Hall outside Room 102 and 105 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 240 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. Material not identified on Previous Report | Good | Contain & Remove | |
| 106 | - | 4 Plaster Walls, Plaster Ceiling and Concrete Floor | ||||||
| 107 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. Fire Door not identified on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 108 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 260 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 2 | door | Material not identified on Previous Report | Good | Wrap & Remove | ||
| Hall outside Room 107 & Room 108 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 330 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. Material not identified on Previous Report | Good | Contain & Remove | |
| 109 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 70 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | Material not identified on Previous Report | Good | Contain & Remove | ||||
| 110 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 130 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Material not identified on Previous Report | Good | Wrap & Remove | ||
| 111 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 130 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Material not identified on Previous Report | Good | Wrap & Remove | ||
| 112 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 50 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Material not identified on Previous Report | Good | Wrap & Remove | ||
| 113 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 120 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| Hallway outside Room113 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 224 | SF | Material not identified on Previous Report. 2 blackboards, one green and one black. | Good | Contain & Remove | |
| Blackboard | BB | 2 | blackboard | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report. Area identified as 1-C-2 | Good | Wrap & Remove | ||
| 114 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 78 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Pipe Insulation Suspect | PI | 10 | LF | Wall Chase in room reveals approximately 10lin.ft. of pipe 5/9/13 - inspected pipe chase visually and by touch, insulation feels like fiberglass, or is obviously fiberglass by appearance. | Contain, Glove Bag & Remove | |||
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| Hallway outside Room115 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 140 | SF | Material identified not on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report. Area identified as 1-C-2 | Good | Wrap & Remove | ||
| 116 | Exterior Window Caulk | EWC | 26 | windows | Plaster Ceiling, Floor Tile and Mastic identified not on Previous Report. | Good | Regulated Area | |
| 117 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 1899 | SF | Drywall Ceiling, Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 1x1 White/Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | Good | ||||||
| Fire Door | FD | 1 | door | Fire Door Assumed Material identified not on Previous Report | Good | Wrap & Remove | ||
| 118 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 120 | SF | Floor Tile and Mastic identified not on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 119 | Fire Door | FD | 1 | door | Plaster ceiling and Fire Door Assumed Material identified not on Previous Report | Good | Wrap & Remove | |
| 120 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 324 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 120A | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 20 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 121 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | 15 | SF | Material identified on Previous Report was not found during inspection: Material Quantity approximated from CAD drawing. | Good | Contain & Remove | |
| 2nd Floor | ||||||||
| Building#1 was assessed, but 1st Floor only. | ||||||||
| Per Andrew Hawk visual of basement and 2nd Floor ceiling and floor | ||||||||
| were badly damaged (Structurally Unsound). Kimball was not permitted to inspect. | ||||||||
| Material in rooms on the 2nd Floor listed in previous report is Positive or Assumed. | ||||||||
| 200 | Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | |||
| 204 | Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | |
| 205 | 1x1 White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | ||
| 206 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | 6 | |
| 207 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | ||
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 209 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | ||
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Wrap & Remove | |||
| 210 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | damaged | Contain & Remove | ||
| 211 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | damaged | Contain & Remove | ||
| 212 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | damaged | Contain & Remove | ||
| 213 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | damaged | Contain & Remove | ||
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 214 | 1x1 White & Beige Mottled Floor Tile w/ Associated Mastic Mastic Positive | MFT | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | damaged | Contain & Remove | ||
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| Attic | Exterior Window Caulk | EWC | 12 | windows | Exterior Window Caulk samples collected during current inspection. Positive | Good | Regulated Area | |
| 18 |
Bldg 2
| Room/Area | Material Description | Material Abbr. | Material Quantity | Unit of Measure | Comments | Condition | Method of Abatement | |
| Basement | ||||||||
| 001 | Fire Door | FD | 1 | door | Concrete Floor, partial Plaster wall and ceiling. Fiberglass pipe lines, Fire Door Assumed not on Previous Reports | Good | Wrap & Remove | |
| 002 | Fire Door | FD | 1 | door | Brick Walls, Concrete Floor and Fiberglass pipe lines, Fire Door Assumed on Previous Report | Good | Wrap & Remove | |
| 003 | Fire Door | FD | 1 | door | Concrete Floor and Partial Drywall on 3 walls. Fire Door Assumed on Previous Report | Good | Wrap & Remove | |
| 004 | Fire Door | FD | door | Concrete Floor and Plaster Ceiling. Fiberglass line and Aircell insulation visible at ceiling. Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 005A | Fire Door | FD | 1 | door | Concrete Floor and Plaster with Skim coat walls. Fire Door Assumed not on Previous Report | Good | Wrap & Remove | |
| 1st Floor | ||||||||
| 100 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 144 | SF | Mastic Associated w/ Floor Tile Assumed to be Positive on Previous Report. Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 101 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 135 | SF | Locked: Floor Tile Assumed to be Positive on Previous Report: Quantity approximated from CAD drawing | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 102 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 30 | SF | Floor Tile Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 103 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 312 | SF | Floor Tile Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | 4432 |
| 105 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 153 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 106 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 342 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 107 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 32 | SF | FT1 not identified during inspection as noted on previous report; Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 108 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 140 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 109 | Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | |
| 110 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 84 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report; Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 111 | Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | |
| 112 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 120 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| 113 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 110 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report; Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 114 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 115 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 208 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 116 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 208 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 117 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 28 | SF | Drywall Ceiling, Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 118 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 108 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report ;Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 119 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 198 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report; Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 120 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 324 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 121 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 323 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report ;Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 1-S-1 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 202 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 1-S-3 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 99 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| 1-C-1 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 1-C-2 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 357 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| 1-C-3 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 225 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| 1-C-4 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 190 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 2nd Floor | ||||||||
| 200 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 70 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 201 | Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 202 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 120 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 203 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 120 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| Fire door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 204 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 108 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report | Good | Contain & Remove | |
| Fire door | FD | 1 | door | Fire Door Assumed on Previous Report | Good | Wrap & Remove | ||
| 205 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 108 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | 4454 |
| 206 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 156 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 207 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 120 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 208 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 140 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 209 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 96 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 210 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 187 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report. | Good | Contain & Remove | |
| 211 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 212 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 213 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 340 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 214 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 90 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 215 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 200 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 216 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 168 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 217 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 224 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 218 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 250 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 219 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 100 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 220 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 126 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 221 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 126 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 222 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 150 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 2-S-1 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 60 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 2-S-2 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 60 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 2-S-3 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 80 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 2-C-1 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 450 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 2-C-2 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 220 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report: Fire door not identified during inspection as noted on previous report | Good | Contain & Remove | |
| 2-C-3 | 1x1 Gray with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 225 | SF | Floor Tile with Associated Mastic Assumed to be Positive on Previous Report. Quantity Includes hall outside Room 206 | Good | Contain & Remove | |
| 1st Floor | Exterior Black Window Caulk | EWC | 32 | windows | Exterior Black Window Caulk was Sampled and Tested Positive | Good | Regulated Area | |
| 2nd Floor | EWC | 40 | windows | Good | Regulated Area | |||
| Attic | EWC | 16 | windows | Good | Regulated Area |
Bldg 3
| Room/Area | Material Description | Material Abbr. | Material Quantity | Unit of Measure | Comments | Condition | Method of Abatement | |
| Basement | ||||||||
| 1 | Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | ||
| 2 | Interior Window Caulk | IWC | 4 | windows | Good | Contain & Remove | ||
| 2A | Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | ||
| 3 | Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | ||
| 4 | Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | ||
| 5 | Interior Window Caulk | IWC | 5 | windows | Good | Contain & Remove | ||
| 5A | Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | ||
| 6 | Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | ||
| 1st Floor | ||||||||
| 100 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 95 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 100A | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 80 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report Fire Door Assumed on previous report. | Good | Contain & Remove | 5368 |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 101 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 162 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report: Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 102 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 120 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 103 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 120 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report: Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 104 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 84.5 | SF | Fire Door Assumed on previous Report Mastic Associated w/ Floor Tile Positive on Previous Report Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 105 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 76.5 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 105A | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 36 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 106 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 20 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 107 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report: Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 3 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 108 A/B | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 252 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report: Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 3 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| 109 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 63 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 110 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 112.5 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report: Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Contain & Remove | ||||
| Fire Door | FD | 1 | door | Wrap & Remove | ||||
| 111 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 117 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 112 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 130.5 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 113 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 104 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 114 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 98 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| 115 | Interior Window Caulk | IWC | 1 | window | Interior Window Caulk not identified on previous report. | Good | Contain & Remove | |
| 116/Porch | Interior Window Caulk | IWC | 27 | windows | Interior Window Caulk not identified on previous report: Mastic Associated w/ Floor Tile Positive on Previous Report . | Good | Contain & Remove | |
| 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 696 | SF | Good | Contain & Remove | |||
| 117 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 1450 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 7 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 118 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 168 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report: Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 120 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 340 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| 120A | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 30 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report : Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 1-S-1 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. | Good | Wrap & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| 1-S-2 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 35 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 1-S-3 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. Interior Window Caulk not identified on previous report | Good | Wrap & Remove | |
| Interior Window Caulk | IWC | 1 | window | Good | Contain & Remove | |||
| 1-C-1 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 180 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 1-C-1A | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 250 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 1-C-1B | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 144 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| 1-C-2 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 224 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| 2nd Floor | ||||||||
| 201 | 1’x1’ Mottled White/Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | 384 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Interior Window Caulk not identified on previous report | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| 202 | 1’x1’ Mottled White/Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | 340 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| 203 | 1’x1’ Mottled White/Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | 300 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 5 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 204 | 1’x1’ Mottled White/Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | 55 | windows | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report. | Good | Contain & Remove | 4823 |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 205 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 340 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Interior Window Caulk not identified on previous report | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 3 | windows | Good | Contain & Remove | |||
| 206 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 153 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 1 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 207 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 52 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 208 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove | |
| 209 | Fire Door | FD | 1 | door | Mastic Associated w/ Floor Tile Positive on Previous Report Fire Door Assumed on previous report. | Good | Wrap & Remove | |
| 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 50 | SF | Good | Contain & Remove | |||
| 210 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Wrap & Remove | |
| Interior Window Caulk | IWC | 5 | windows | Good | Contain & Remove | |||
| 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 425 | SF | Good | Contain & Remove | |||
| 211 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Wrap & Remove | |
| 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 320 | SF | Good | Contain & Remove | |||
| 212 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Wrap & Remove | |
| 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 384 | SF | Good | Contain & Remove | |||
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| 213 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 280 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | |||
| 213A | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 42 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 214 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 7 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 2-C-1 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 750 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. Fire Door Assumed on previous report. | Good | Contain & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | |||
| 2-C-2 | 1’x1’ White with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 468 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 2-C-3 | 1’x1’ Tan/White/Gray Floor Tile w/Associated Mastic Mastic Positive | MFT | 468 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 2-S-1 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. | Good | Wrap & Remove | |
| Interior Window Caulk | IWC | 2 | windows | Good | Contain & Remove | |||
| 2-S-2 | 1’x1’ White with Brown Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 60 | SF | Mastic Associated w/ Floor Tile Positive on Previous Report | Good | Contain & Remove | |
| 2-S-3 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report. | Good | Wrap & Remove | |
| Interior Window Caulk | IWC | 3 | windows | Good | Contain & Remove | |||
| Attic | Interior Window Caulk | IWC | 12 | windows | Interior Window Caulk not identified on previous report. Sample collected during current inspection Positive. | Good | Contain & Remove |
Bldg 4
| Room/Area | Material Description | Material Abbr. | Material Quantity | Unit of Measure | Comments | Condition | Method of Abatement |
| Basement | |||||||
| 1 | Exterior Window Caulk | EWC | 2 | windows | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| 2 | Exterior Window Caulk | EWC | 5 | windows | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| 2A | Exterior Window Caulk | EWC | 1 | window | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove | |
| 3 | Exterior Window Caulk | EWC | 1 | window | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove | |
| 4 | Exterior Window Caulk | EWC | 1 | window | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| 5 | Exterior Window Caulk | EWC | 4 | windows | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| 5A | Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove |
| 6 | Exterior Window Caulk | EWC | 2 | windows | Exterior Window Caulk not identified on previous report. Sample collected Positive. | Good | Regulated Area |
| 1st Floor | |||||||
| 100 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 100 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | ||
| 100A | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 66.5 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 101 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 170 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 102 | 1’x1’Tan with Tan & Gray Splotches Floor Tile w/Associated Mastic Mastic Assumed Positive | MFT | 120 | SF | MFT4 identified Mastic Positive on Previous Report. Not There. Mastic Assumed Positive | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove | |
| 103 | 1’x1’ Brown with White Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 240 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | ||
| 104 | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 81 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 105A | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 96 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 106 | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 300 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 106A | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 96 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 107 | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 96 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 109 | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 108 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 110 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 140 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 111 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 112 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 112 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 96 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 2 | door | Good | Wrap & Remove | ||
| 113 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove |
| 114/Porch | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 360 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | ||
| 115 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 1708 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 115A | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 12 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 115B | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 12 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 116 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 110 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 118 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 732 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 2 | doors | Good | Wrap & Remove | ||
| 120 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 12 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove | |
| 120A | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 12 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. | Good | Contain & Remove |
| 1-S-1 | Fire Door | FD | 2 | doors | Fire Door Assumed on previous report | Good | Wrap & Remove |
| 1-S-2 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 45 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 1-S-3 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove |
| 1-C-1 | 1’x1’Tan with White Splotches Floor Tile w/ Associated Mastic Mastic Positive | MFT | 162 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 1-C-2 | 1’x1’Tan with Brown Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 285 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 140 | SF | Good | Contain & Remove | ||
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 2nd Floor | |||||||
| 200 | Fire Door | FD | 1 | door | Fire Door Assumed on previous report | Good | Wrap & Remove |
| 201 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 170 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 202 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 320 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 203 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 325 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 204 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 35 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 205 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 170 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove | ||
| 206 | 1’x1’ White with Tan Splotches Floor Tile w/Associated Mastic Mastic Positive | MFT | 162 | SF | Mastic Associated w/Floor Tile Positive on Previous Report. Fire Door Assumed on previous report | Good | Contain & Remove |
| Fire Door | FD | 1 | door | Good | Wrap & Remove |