36C24618R0842-005.pdf
PDF 11 MB Posted
- Attached to
- Project 659-16-101, Correct Operating Room Deficiencies Federal contract opportunity
- Solicitation number
- 36C24618R0842
About this file
36C24618R0842 CONTRACT ATTACHMENT A - DRAWINGS - FILE 4 - Mechanical.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24618R0842-0002004.pdf | ||
| 36C24618R0842-0002002.pdf | ||
| 36C24618R0842-0002000.docx | DOCX document | |
| 36C24618R0842-0002003.pdf | ||
| 36C24618R0842-0002001.pdf | ||
| 36C24618R0842-008.docx | DOCX document | |
| 36C24618R0842-007.pdf | ||
| 36C24618R0842-006.pdf | ||
| 36C24618R0842-002.pdf | ||
| 36C24618R0842-003.pdf | ||
| 36C24618R0842-001.docx | DOCX document | |
| 36C24618R0842-009.pdf | ||
| 36C24618R0842-004.pdf | ||
| 36C24618R0842-000.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO SCALE
TEMPERATURE SENSOR
UNDERWRITER'S LABORATORIES
UNLESS OTHERWISE NOTED
SYMBOL OR SYMMETRICAL
TEST, ADJUST, BALANCE
SUPPLY REGISTER
STANDARD CUBIC FEET PER MINUTE
SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
STATIC PRESSURE
VARIABLE SPEED
WEATHER PROOF
VARIABLE FREQUENCY DRIVE
VARIABLE VOLUME
WET BULB TEMPERATUREWb
INSUL
LAT
LB/HR
KW
HTG
HVAC
HOA
HORZ
H'STAT
HR
HP
HD
GPH
GPM
HC
IN
ID
HEATING, VENTILATING, AND AIR CONDITIONING
INSIDE DIAMETER
LEAVING AIR TEMPERATURE
POUNDS PER HOUR
INSULATED
KILOWATT
HEATING
INCH
HEAT DETECTOR
HAND-OFF-AUTOMATIC
HORSEPOWER
GALLONS PER HOUR
GALLONS PER MINUTE
HUMIDITY CONTROLLER
HORIZONTAL
HUMIDISTAT
HOUR
WP
WG WATER GAGE
FCV
GALV
GC
GAL
FSD
FT
FV
FS
FPC
FPM
FPS
FLEX
FLG
FD
F&T
F.D.
FC
EQUIP
ESP
EWT
EXH
ER
EC
EFF
ELEC
EL
EQ
EAT
EA
F
FIRE PROTECTION CONTRACTOR
FEET PER SECOND
FLOW SWITCH/SENSOR
GENERAL CONTRACTOR
COMBINATION FIRE/SMOKE DAMPER
FEET PER MINUTE
FEET
GALVANIZED
GALLON(S)
FLOW VALVE
FLOW CONTROL VALVE
FLANGE
FIRE DAMPER
FLEX
VERT
W/
W/O
VFD
VOL
VS
VLV
WITHOUT
WITH
VERTICAL
VOLUME
VALVE
THRU
T'STAT
UL
V
UON
TYP
TS
THERMOSTAT
TYPICAL
THROUGH
EXHAUST REGISTER
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
FLOAT AND THERMOSTATIC
FLOW CONTROLLER
FAHRENHEIT
FLOOR DRAIN
EXHAUST
ENTERING AIR TEMPERATURE
ELECTRICAL CONTRACTOR
ELEVATION
ELECTRICAL
EQUAL
EQUIPMENT
EXHAUST AIR
EFFICIENCY
STRUCT
TAB
SYM
SYS
STL
STM
SR
SQ
STRUCTURAL
SYSTEM
STEEL
STEAM
SQUARE
SMACNA
SPEC
SECT
SCFM
SP
SCH
SD
SA
SECTION
SPECIFICATION
SMOKE DAMPER
SCHEDULE
SUPPLY AIR
LOW SIDE WALL EXHAUST REGISTER
LEAVING WATER TEMPERATURE
RELATIVE HUMIDITY
REVOLUTIONS PER MINUTE
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCH GAGE
REFLECTED CEILING PLAN
POUNDS PER SQUARE INCH
PLUMBING CONTRACTOR
OUTSIDE DIAMETER
MOTOR OPERATED DAMPER
NATIONAL ELECTRICAL MANUFACTURER'S
NOT IN CONTRACT
NORMALLY CLOSED
MECHANICAL CONTRACTOR
MANUAL DAMPER
MANUFACTURERMFR
ARCH ARCHITECTURAL
DWG
Db
DEG(°)
DPR
DTF
DP
DN
CTR
DD
CU
CONN
CONT
CONTR
COP
CONST
COORD
CFH
CFM
CLG
CONC
ASHRAE
BDD
ASME
BHP
AUTO
BTUH
BTU
BV
C
DOWN THRU FLOOR
DUCT MOUNTED SMOKE DETECTOR
DRAIN POINT
DRAWING
DAMPER
DRY BULB TEMPERATURE
DEGREE(S)
DOWN
COEFFICIENT OF PERFORMANCE
CONSTRUCTION
COPPER
CENTER
CONNECTION
CONTINUATION
CONTRACTOR
COORDINATE
REINF
REQD
RH
RPM
RM
REV
RD
RA
RCP
REQUIRED
ROOM
REVISION
RETURN AIR
REINFORCING
ROUND
PSIG
QTY
PSI
PSIA
QUANTITY
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
CONSTANT VOLUME
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
BRITISH THERMAL UNIT PER HOUR
BRITISH THERMAL UNIT
BUTTERFLY VALVE
CEILING
CONCRETE
BACKDRAFT DAMPER
AND AIR CONDITIONING ENGINEERS
BRAKE HORSEPOWER
AUTOMATIC
NIC
OPNG
OA
P.C.
OD
OC
NTS
NO.
OUTSIDE AIR
ON CENTER
OPENING
NOT TO SCALE
NUMBER
NEMA
NC
MOD
MIN
ASSOCIATION
MINIMUM
AD
AFMS
ALUM
AFF
AC/HR
ANSI
APPROX
AMCA
ABV.CLG.
Ø
AIR MOVEMENT AND CONTROL ASSOCIATION
AMERICAN NATIONAL STANTDARDS INSTITUTE
AIR FLOW MONITORING STATION
ACCESS DOOR
ABOVE FINISHED FLOOR
AIR CHANGES PER HOUR
ALUMINUM
APPROXIMATE
ABOVE CEILING
POUNDS OR NUMBER
ROUND, DIAMETER OR PHASE
LSWER
MECH
MFG
MD
MAX
MC
MBH
MANUFACTURING
MECHANICAL
MAXIMUM
BTUH x 1000
LF
LWT
LINEAR FEET
FVNR FULL VOLTAGE, NON-REVERSING, MAGNETIC
W WATTS
AHU-1 AIR HANDLING UNIT & TAG
CC COOLING COIL
CP-1 CONDENSATE PUMP & TAG
DB DECIBELS
Dp DEWPOINT TEMPERATURE
CW COLD WATER (DOMESTIC)
EF-1 EXHAUST FAN & TAG
E or EX. EXISTING
NOT ALL ABBREVIATIONS SHOWN
IN THIS LIST WERE UTILIZED FOR
THIS PROJECT.
AMERICAN SOCIETY OF HEATING, REFRIGERATING,
NOT APPLICABLEN/A
SIDEWALL RETURN REGISTER
CEILING RETURN GRILLE/
SIDEWALL EXHAUST REGISTER
CEILING EXHAUST GRILLE/
DUCTWORK W/O DUCTLINER
SIDEWALL SUPPLY REGISTER
CEILING SUPPLY DIFFUSER/
MOTOR OPERATED DAMPER
DAMPER WITH ACCESS DOOR
COMBINATION FIRE/SMOKE
DOOR
ACCESS DOOR
DETECTOR WITH ACCESS
DUCT MOUNTED SMOKE
SMOKE DAMPER WITH
WITH ACCESS DOOR
MANUAL DAMPER
ACCESS DOOR
FIRE DAMPER WITH
DOUBLE LINE
EQUIPMENT
TRANSITION
DESCRIPTION
OVAL TRANSITION
SQUARE TO ROUND/
CONICAL TAKEOFF
RECTANGULAR DUCT
MITERED TAKEOFF
(SEE SCH)
(SEE SCH)
REGISTER (SEE SCH)
DOUBLE LINE
(SEE SCH)
REGISTER (SEE SCH)
REGISTER (SEE SCH)
DESCRIPTION
MEDIUM PRESSURE STEAM CONDENSATE (60 PSI)
LOW PRESSURE STEAM SUPPLY (15 PSI)
LOW PRESSURE STEAM CONDENSATE (15 PSI)
MEDIUM PRESSURE STEAM SUPPLY (60 PSI)
MPC
MPS
LPS
LPCR
HWR
HWS HOT WATER SUPPLY
HOT WATER RETURN
D
CHWS
CHWR
DRAIN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
BOX NUMBER (C OR V INDICATES
500 CFM
1-4-XC
VARIABLE OR CONSTANT VOLUME BOX WITH REHEAT
HOT WATER GPM
CONSTANT OR VARIABLE FLOW)
24" OF ROUND HARD DUCTWORK
VARIABLE OR CONSTANT REGULATOR
ACCESS DOOR
SUPPLY CFM
REHEAT COIL
FLOOR
AIR HANDLING UNIT NUMBER
1 GPM
AIR FLOW MONITORING
STATION
DUCT MOUNTED COIL
(HOT WATER)
EXHAUST DUCT UP
SUPPLY AND RETURN SIMILAR
RETURN DUCT DOWN
SUPPLY AND EXHAUST SIMILAR
SUPPLY DUCT, UP THROUGH ROOF
RETURN AND EXHAUST SIMILAR
DRAWING NUMBER WHERE SECTION
EMERGENCY STOP SWITCH
DIRECTION OF AIR FLOW
CONNECT TO EXISTING SYMBOL
THERMOMETER WELL AND CAP ONLY
THERMOMETER WITH WELL
12x10 DUCT SYMBOL: RECTANGULAR
TEMPERATURE SENSOR
IS LOCATED
T
SECTION NUMBER
HUMIDITY SENSORH
ESS
MISCELLANEOUS
CFM
ARROW AND CFM
DUCT SYMBOL: ROUND12Ø
UNION
LINE PRESSURE RELIEF VALVE
MANUAL AIR VENT POINT ON PIPE
LOW PRESSURE TRAP ASSEMBLY
AUTOMATIC FLOW LIMITING DEVICE
PIPE UP
PIPE DOWN
(SEE SPECS)
FLOW SWITCH
ACCESSORIES
DIRECTION OF FLOW
DIRECTION OF SLOPE
THREE WAY VALVE
AUTOMATIC CONTROL VALVE
VALVES
BALL VALVE
ISOLATION VALVE
CHECK VALVE
BUTTERFLY VALVE
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
AIR VALVE
M4.1
TO REMAIN
TO BE REMOVED
EXISTING DUCT
EXISTING EQUIPMENT
TO REMAIN
TO BE REMOVED
EXISTING PIPING
EXISTING PIPING
TO REMAIN
EXISTING CONDENSATE DRAIN
TO BE REMOVED
EXISTING EQUIPMENT
TO REMAIN
EXISTING DUCT
NEW EQUIPMENT
NEW PIPING
NEW
DUCTWORK
MEDIUM PRESSURE TRAP ASSEMBLY
AFLD AUTOMATIC FLOW LIMITING DEVICE
HUMIDIFIER
FSD
SD
M
FD
DD
M4
ABBREVIATIONS
GENERAL NOTES
DUCTWORK
PIPING
LEGEND
D
DRAWING
DRAWING INDEX
TITLE
MECHANICAL - NOTES, LEGEND AND DRAWING INDEX
MECHANICAL - DETAILS
MECHANICAL - DETAILS
MECHANICAL - SEISMIC DETAILS
MECHANICAL - SCHEDULES
MECHANICAL - SCHEDULES
MECHANICAL - AHU
MECHANICAL - THIRD FLOOR - DEMOLITION - DUCTWORK - AREA C
MECHANICAL - THIRD FLOOR - DEMOLITION - PIPING - AREA C
MECHANICAL - FOURTH FLOOR - DEMOLITION - DUCTWORK - AREA A
MECHANICAL - FOURTH FLOOR - DEMOLITION - DUCTWORK - AREA B
MECHANICAL - FOURTH FLOOR - DEMOLITION - DUCTWORK - AREA C
MECHANICAL - FOURTH FLOOR - DEMOLITION - PIPING - AREA A
MECHANICAL - FOURTH FLOOR - DEMOLITION - PIPING - AREA B
MECHANICAL - FOURTH FLOOR - DEMOLITION - PIPING - AREA C
MECHANICAL - FOURTH FLOOR - DEMOLITION - CHILLED WATER - AREA A
MECHANICAL - FOURTH FLOOR - DEMOLITION - CHILLED WATER - AREA B
MECHANICAL - FOURTH FLOOR - DEMOLITION - CHILLED WATER - AREA C
MECHANICAL - FOURTH FLOOR - PIPING - SUPPLEMENTAL AREA C
MECHANICAL - FIFTH FLOOR - DEMOLITION - DUCTWORK - AREA A
MECHANICAL - FIFTH FLOOR - DEMOLITION - DUCTWORK - AREA B
MECHANICAL - FIFTH FLOOR - DEMOLITION - DUCTWORK - AREA C
MECHANICAL - FIFTH FLOOR - DEMOLITION - PIPING - AREA A
MECHANICAL - FIFTH FLOOR - DEMOLITION - PIPING - AREA B
MECHANICAL - ROOF - DEMOLITION
MECHANICAL - ROOF - DEMOLITION - CHILLED WATER
MECHANICAL - THIRD FLOOR - NEW WORK - DUCTWORK - AREA C
MECHANICAL - THIRD FLOOR - NEW WORK - PIPING - AREA C
MECHANICAL - FOURTH FLOOR - NEW WORK - DUCTWORK - AREA A
MECHANICAL - FOURTH FLOOR - NEW WORK - DUCTWORK - AREA B
MECHANICAL - FOURTH FLOOR - NEW WORK - DUCTWORK - AREA C
MECHANICAL - FOURTH FLOOR - NEW WORK - PIPING - AREA A
MECHANICAL - FOURTH FLOOR - NEW WORK - PIPING - AREA B
MECHANICAL - FOURTH FLOOR - NEW WORK - PIPING - AREA C
MECHANICAL - FOURTH FLOOR - NEW WORK - CHILLED WATER - AREA B
MECHANICAL - FOURTH FLOOR - NEW WORK - CHILLED WATER - AREA C
MECHANICAL - FIFTH FLOOR - NEW WORK - DUCTWORK - AREA A
MECHANICAL - FIFTH FLOOR - NEW WORK - DUCTWORK - AREA B
MECHANICAL - FIFTH FLOOR - NEW WORK - DUCTWORK - AREA C
MECHANICAL - FIFTH FLOOR - NEW WORK - PIPING - AREA A
MECHANICAL - FIFTH FLOOR - NEW WORK - PIPING - AREA B
MECHANICAL - FIFTH FLOOR - NEW WORK - PIPING - AREA C
MECHANICAL - FIFTH FLOOR - NEW WORK - CHILLED WATER - AREA A
MECHANICAL - FIFTH FLOOR - NEW WORK - CHILLED WATER - AREA B
MECHANICAL - ROOF - NEW WORK
M001 M002 M002A M003 M004 M004A M005
MD300C
MD301C
MD400A
MD400B
MD400C
MD401A
MD401B
MD401C
MD402A
MD402B
MD402C
MD403C
MD500A
MD500B
MD500C
MD501A
MD501B
MD600
MD601
M300C M301C M400A M400B M400C M401A M401B M401C M402B M402C M500A M500B M500C M501A M501B M501C M502A M502B M600
A. ALL DUCTS, PIPE, AND EQUIPMENT SHALL BE LATERALLY RESTRAINED TO COMPLY WITH
THE NORTH CAROLINA BUILDING CODE.
B. BEFORE FABRICATING ANY SHEET METAL DUCTWORK, COORDINATE LOCATION AND SIZE
WITH SPRINKLER & PLUMBING PIPING, CONDUITS, LIGHT FIXTURES, STRUCTURAL, ETC.
PLANS ARE SCHEMATIC AND ARE NOT SHOP DRAWINGS. SUBMIT DUCTWORK
COORDINATION DRAWINGS, AS SPECIFIED.
C. BEFORE SUBMITTING SHOP DRAWINGS, COORDINATE VOLTAGES AVAILABLE FOR
MECHANICAL EQUIPMENT AND PROVISION OF ALL STARTERS AND DISCONNECT
SWITCHES WITH ELECTRICAL CONTRACTOR.
D. ALL EQUIPMENT SHALL BE U.L. LISTED.
E. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT;
PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT AND
WIRE VFD, UNLESS OTHERWISE NOTED.
F. FIRE AND SMOKE DAMPERS SHALL BE INSTALLED IN COMPLETE ACCORDANCE WITH THE
MFR'S. U.L. LISTING AND INSTALLATION INSTRUCTIONS. FIRE AND SMOKE DAMPERS
SHALL HAVE SPECIFIC U.L. LISTING FOR THE CONSTRUCTION IN WHICH THEY ARE
INSTALLED.
G. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER
TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK INSTALLED BY THIS
CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF COORDINATION BETWEEN
TRADES, SHALL BE CHANGED AS DIRECTED BY THE ARCHITECT/ENGINEER WITHOUT
ADDITIONAL COMPENSATION TO THE CONTRACTOR.
H. DUCT MOUNTED SMOKE DETECTORS SHALL BE FURNISHED BY ELECTRICAL CONTRACTOR
AND INSTALLED BY THE MECHANICAL CONTRACTOR. PROVIDE DUCT ACCESS DOOR AT
EACH DETECTOR. INSTALL DETECTORS IN COMPLETE ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
I. MECHANICAL CONTRACTOR SHALL COORDINATE ROUTING OF DUCTWORK TO ENSURE
DUCTWORK DOES NOT PASS OVER ELECTRICAL PANELS.
J. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE SCALE,
WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.
K. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE OWNERS
REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK. THIS TIME
LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL BE AT THE
OWNERS DISCRETION.
L. PROVIDE ESCUTCHEON PLATES WHERE DUCTS PENETRATE CEILINGS OR WALLS IN
AREAS EXPOSED TO VIEW. ESCUTCHEONS FOR DUCTS SHALL BE CONSTRUCTED OF
SAME MATERIAL AS DUCT. PIPE ESCUTCHEONS SHALL BE CHROME-PLATED BRASS.
M. LEAVE A MINIMUM CLEARANCE OF 2 INCHES ABOVE DUCTS INSTALLED IN RATED
PARTITIONS TO ALLOW SPACE FOR THE GENERAL CONTRACTOR TO SEAL THE WALL
ABOVE THE DUCTS. DO NOT INSTALL FLEXIBLE DUCT THROUGH RATED WALLS,
BARRIERS OR PARTITIONS.
N. PROVIDE REMOVABLE ACCESS DOORS AT ALL MOTOR OPERATED DAMPERS, FIRE
DAMPERS, SMOKE DAMPERS, DUCT COILS, SMOKE DETECTORS, AND SIMILAR ITEMS
REQUIRING MAINTENANCE OR ADJUSTMENT.
number of phases minimum efficiency
# of poles motor type
SEE SCHEDULE SHEET
SEE SCHEDULE SHEET
SEE SCHEDULE SHEET
Method of Compliance
VARIABLE VOLUME AIR HANDLING EQUIPMENT description of unit
Equipment schedules with motors (mechanical systems) total chiller capacity. If oversized, state reason.
total boiler output. If oversized, state reason.
Chiller motor horsepower
List equipment efficiencies cooling output of unit heat output of unit cooling efficiency heating efficiency
Boiler
SEE SCHEDULE SHEET
SEE SCHEDULE SHEET
SEE SCHEDULE SHEET
N/A
N/A
SEE SCHEDULE
SEE SCHEDULE
SEE SCHEDULE
SEE SCHEDULE
Energy Cost Budget
Mechanical Spacing Conditioning System summer dry bulb
Building cooling load
Building heating load relative humidity
Unitary
Prescriptive winter dry bulb Interior design conditions summer dry bulb winter dry bulb Thermal Zone
X
75.0°F
1,480 MBH
2,329 MBH
50.0%
72.0°F
91.7°F 24.6°F 3A
MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT
MAXIMUM ACCEPTABLE SOUND LEVELS
TYPE OF ROOM NC LEVEL
BATHROOMS AND TOILET ROOMS
CONFERENCE ROOMS
CORRIDORS (NURSE STATIONS)
CORRIDORS (PUBLIC)
EXAMINATION ROOMS
OFFICES, LARGE OPEN (3 OR MORE OCCUPANTS)
OFFICES, SMALL PRIVATE (2 OR FEWER OCCUPANTS)
PATIENTS ROOMS
TREATMENT ROOMS
X-RAY AND GENERAL WORK ROOMS
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000
Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/8
/2
:3
:2
A
M D
L o c a l R e v it
F ile s \3
C
E
C e n tr a l
M o d e l.
rv t
M001
MECHANICAL - NOTES,
LEGEND AND DRAWING
INDEX
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
KAT
GAT
Salisbury, NC
100% FINAL DESIGN
11/10/16
Item Date Description
1 05/08/17 Revision 1
(LUG TYPE)
BUTTERFLY VALVE
PT TEST PLUG
SUPPLY
LIMITING DEVICE
AUTOMATIC FLOW
RETURN
UNION
THERMOMETER
MANUAL AIR VENT
DRAIN VALVE
TWO WAY VALVE
BUTTERFLY
VALVE
M
J
S
STEAM COIL
CONTROL VALVE STRAINER
GATE VALVE
1/4" PET COCK VENT
VACUUM BREAKER
LPR
F&T TRAP
TEMPERATURE
CONTROL SENSOR
VACUUM
BREAKER
14" MINUMUM
NTS
LPS
SUPPORTED DUCT
NAILER STRIP
FLASHING
ROOF DECK
NTS
OVERFLOW DRAIN
PRESSURE STEAM INLETSTEAM OUTLETS
F/T
STEAM
CONDENSATE
NTS
DRAIN
STEAM
TRAP
AIR FLOW
NTS
STEAM PRESSURE REDUCING VALVE STATION (LOCATED IN AHU-11)
NOTES:
1. PROVIDE INTEGRAL CONDENSATE COOLER.
STEAM TO STEAM HUMIDIFIER DETAIL
10"MIN
FLOOR STAND ASSEMBLY
CONTROL PANEL
AUXILIARY DRAIN FOR
MAINTENANCE
STEAM-TO-STEAM
HUMIDIFIER
1/4"x1 1/2"
LONG LAG BOLTS
W/WASHERS
GALV TIE DOWN
AROUND DUCT
DUCT SUPPORT ON ROOF
STEAM COIL PIPING
CONTROL
VALVE WATER
INLET
STEAM PRESSURE REDUCING VALVE STATION (LOCATED IN AHU-4)
B-LINE "C-PORT"
CHANNEL SUPPORT
CAT. NO. C10
OR EQUAL.
14 GA. GALV. CHANNEL
B-LINE "BVT" SERIES CLAMP
GAS OR CONDENSATE PIPING
INSTALL IN ACCORDANCE WITH
MANUFACTURER'S INSTALLATION
INSTRUCTIONS.
ROOF
APPROVED EQUAL: PIPE PIER BY
MICHIGAN HANGER CO. INC.
ROOFTOP PIPE SUPPORT
NTS
NTS
DIFFERENTIAL PRESSURE MONITOR DETAIL
VFD
ROOF
SP
ROOFING
COORDINATE PATCH
EXISTING BUILT-UP
WITH ROOFING
CONTRACTOR
NTS
3 3
NTS
NTS
R
NTS
BRANCH DUCT
NTS
BRANCH DUCT
DUCT
NTS
48"
2"
FINISH FLOOR
DEVICES BY ELECTRICAL
CONTRACTOR
THERMOSTAT
NTS
NTS
HWS
HWR
UNION
BALL VALVE
AFLD
AIR VENT
J
NTS
PRV-2A 100 15 585 1/2"
SRV-2A 20 1,760 J
PRV-2B 100 15 1175 1"
FULL
NORMAL
PRV-2B
1 1/2"
2 1/2"
2 1/2"
TO LPC
PRV-2A
1 1/2"
1 1/4"
2 1/2"
2"
1"
1 1/4"
NTS
NOTES:
1. INSTALL AIR VENT AT HIGH POINTS ON PIPING.
2. INSTALL DRAIN VALVES AT LOW POINTS OF PIPING.
3. EXTEND COIL VENTS AND DRAINS (IF PROVIDED BY COIL MANUFACTURER)
THROUGH AIR HANDLING UNIT HOUSING.
4. INSTALL FLOW CONTROL DEVICE MINIMUM OF 10 PIPE DIAMETERS STRAIGHT PIPE
(OR MORE IF REQUIRED BY MANUFACTURER) DOWNSTREAM OF NEAREST FITTING.
TYPICAL SINGLE CHILLED WATER COIL PIPING WITH
2-WAY CONTROL VALVE
SAFETY RELIEF VALVE
PRESSURE REDUCING VALVE STATION SCHEDULE
PITCH
DOWN
SAFETY RELIEF VALVE - SRV-1ASTEAM
SUPPLY
PITCH DN.
REDUCED STEAM
PRESSURE SUPPLY
TO EQUIPMENT.
PRESSURE
SENSING
LINES
10 PIPE
DIAMETERS
MINIMUM
MEDIUM
PRESSURE
TRAP
PORT
TYPE
HOFFMAN SERIES 2000
2100 NP
KUNKLE
6252 KJP
1 1/2"INLET/2 1/2" OUTLET
MODEL
ORFICE
SIZE
ACTUAL STEAM
FLOW (LBS/HR)
DISCHARGE
PRESSURE
(psi)
SRV-#
HOFFMAN SERIES 2000
2100 FP
PRESSURE REDUCING VALVES
MODEL
VALVE
SIZE
(in)
STEAM CAPACITY
(LBS/HR)
LEAVING
PRESSURE
(psi)
ENTERING
PRESSURE
(psi)
PRV-#
NOTES
1. PROVIDE ORIFICE TYPE FLOW METER UPSTREAM OF PIPE FLOW AS
REQUIRED.
2. GATE VALVES SHOULD BE FULLY OPEN TO PROVIDE UNRESTRICTED FLOW.
3. PROVIDE PILOT OPERATED REGULATORS.
4. PROVIDE DRIP PAN ELBOW. OUTLET SIZE OF SRV-2A SHALL MATCH INLET OF
DRIP PAN ELBOW.
PILOT LIGHT BY E.C. ON
WHEN SWITCH IS ON.
MOUNT NEXT TO SWITCH.
DISCONNECT SWITCH BY EC.
LOCATE IN AN ACCESSIBLE
LOCATION ABOVE THE CEILING
WITHIN 18" OF OF THE DAMPER
ACCESS DOOR. SWITCH SHALL BE
LEVITON #1221 FOR 120V OR #1081
FOR 24V OR EQUAL. EC SHALL
PROVIDE CIRCUIT LABEL AND
LOCKABLE COVER.
TO OTHER DAMPERS
BY E.C.
FIRE ALARM SYSTEM
CONNECTION REQUIRED
FOR SMOKE AND
FIRE/SMOKE DAMPERS
PROVIDED BY E.C.
FIRE, SMOKE, OR
FIRE/SMOKE
DAMPER BY M.C. ELECTRICAL PANEL LOCATED IN
ELECTRICAL ROOM, PROVIDED BY EC.
WIRING FROM
ELECTRICAL PANEL
JUNCTION BOX
PROVIDED BY E.C.
WIRING FROM JUNCTION
BOX TO DISCONNECT
SWITCH AND FROM
DISCONNECT SWITCH TO
DAMPER ACTUATOR BY EC.
JUNCTION BOX
LOCATED OUTSIDE
ELECTRICAL ROOM
PROVIDED BY E.C.
NOTES:
1. FIRE, SMOKE, AND FIRE/SMOKE DAMPERS SHALL BE U.L. LABELED AND INSTALLED
PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2. ALL WIRING SHALL BE INSTALLED BY DIVISION 26.
3. BASIS OF DESIGN SHALL BE: FIRE DAMPER - RUSKIN FSD-60, SMOKE DAMPER
- RUSKIN SD-60, FIRE/SMOKE DAMPER - RUSKIN FSD-60.
FIRE, SMOKE, & FIRE/SMOKE DAMPER
WIRING DETAIL
120V WIRING
BY CONTROLS
CONTRACTOR
120V BY CONTROLS
CONTRACTOR TO OTHER
TERMINAL UNITS
120V BY ELECTRICAL
CONTRACTOR
24V WIRING BY
CONTROLS
CONTRACTOR
120/24V TRANSFORMER BY
TERMINAL MANUFACTURER.
120V TOGGLE DISCONNECT BY
TERMINAL MANUFACTURER.
PRESSURE/
TEMPERATURE
TEST PLUG
2-WAY VALVE BY CONTROLS
CONTRACTOR, UNLESS NOTED
OTHERWISE ON PLANS
HOSE END DRAIN
VALVE WITH CAP
DDC CONTROLLER SHALL BE
FACTORY MOUNTED
MULTI-
POINT
INLET
SENSOR
24" OF ROUND HARD
DUCTWORK
(VARIABLE VOLUME
BOX ONLY)
HOT WATER HEATING COIL.
(PROVIDE ACCESS DOOR
PRIOR TO COIL FOR
CLEANING COIL)
NOTES:
1. MAINTAIN CLEARANCE ON CONTROL SIDE OF BOX AND INSTALL
SO THAT ACCESS DOORS ARE NOT BLOCKED.
VARIABLE OR CONSTANT VOLUME
TERMINAL UNIT WITH REHEAT
NOTES:
1. PROPERLY COORDINATE DEVICE LOCATION TO ALIGN VERTICALLY.
THERMOSTAT ALIGNMENT
SPIN IN COLLAR.
AIR DISTRIBUTION DEVICE
SEAL INSULATION TO
DUCT WITH CAULKING
SEAL WITH DRAW BAND
AT TAP CONNECTION
AND DIFFUSER/FIXTURE
NOTES:
1. ONLY ONE 90° TURN ALLOWED IN FLEX DUCT. DUCT MUST BE PROPERLY
SUPPORTED TO PREVENT KINKING.
2. IF ADDITIONAL 90° TURNS ARE REQD TO CONNECT OUTLET TO DIFFUSER, EXTEND
TAP AND PROVIDE EXTERNALLY INSULATED SHEET METAL ELLS AS REQD.
CONNECTIONS BETWEEN LOW PRESSURE DUCT
AND AIR DISTRIBUTION DEVICE
FLEX DUCT WITH
EXTERNAL BLANKET
INSULATION (TYP)
EXTEND TAP AS REQ.D TO ALLOW
MAX 5' LENGTH OF FLEX DUCT
BETWEEN CONNECTION AND
DIFFUSER
MANUAL VOLUME DAMPER WITH
QUADRANT LOCKING DEVICE,
WITH STANDOFF RUSKIN MODEL
MDRS25 OR EQUAL.
VOLUME DAMPER (REFER TO
VOLUME DAMPER DETAIL).
VOLUME DAMPER (REFER TO
VOLUME DAMPER DETAIL).
MAIN SUPPLY
AIR FLOW
AIR
FLOW
NOTE:
ALL BRANCH TAKEOFFS SHALL BE 45°, CONICAL OR BELLMOUTH TYPE.
MAIN EXHAUST OR
RETURN AIR FLOW
BRANCH DUCTWORK TAKEOFFS
AIR
FLOW
TYPE RE 1 RADIUS ELBOW
TYPE RE 2 SQUARE THROAT
ELBOW WITH VANES
RECTANGULAR SHEETMETAL ELBOWS
NOTES:
1. CHANGES IN DUCTWORK ELEVATION SHALL BE ACCOMPLISHED BY UTILIZING
RADIUS ELBOW TRANSITIONS EQUAL TO NO LESS THAN R=1.5D. IN ORDER TO
MINIMIZE DUCT STATIC PRESSURE LOSSES.
2. ELEVATION TRANSITION ARROW INDICATING UP OR DOWN (DN) IS SHOWN WITH
RESPECT TO AIRFLOW DIRECTION.
D
R .5
D
PLAN VIEW
ELEVATION CHANGE - OGEE TRANSITION
DETAIL
SIDE VIEW
THROUGH PENETRATION FIRESTOP SYSTEM
(PROVIDE UL LISTED SYSTEM)
NOTES:
1. RATED WALL OR FLOOR ASSEMBLY - PROVIDE FIRE STOPPING ASSEMBLY FOR
PARTITION TYPE & RATING ENCOUNTERED.
2. THROUGH PENETRATION (INSULATED OR BARE DEPENDING ON SERVICE) - PROVIDE
FIRE STOPPING ASSEMBLY FOR SIZE & MATERIAL OF THROUGH PENETRATION
UTILIZED.
3. FIRE STOPPING MATERIAL - PROVIDE FIRE STOPPING MATERIAL FOR WALL
ASSEMBLY & THROUGH PENETRATION MATERIAL ENCOUNTERED. FILL VOIDS OR
CAVITY ACCORDING TO THE REQUIREMENTS OF THE FIRE STOPPING SYSTEM
UTILIZED.
ALL RATED WALLS, PARTITIONS OR FLOORS SHALL BE PROVIDED WITH A UL
LISTED FIRE STOP SYSTEM. THE SYSTEM UTILIZED SHALL MATCH THE
SEPARATION PENETRATED AND THE THROUGH PENETRATION MATERIAL.
DETAILS FOR THE INSTALLATION OF SYSTEM TYPE UTILIZED SHALL BE AVAILABLE
AT THE PROJECT SITE FOR THE DURATION OF CONSTRUCTION AND SHALL BE
PROVIDED TO THE BUILDING OWNER AT THE PROJECT COMPLETION.
PROVIDE WALL OR FLOOR LABELS INDICATING THE SYSTEM MANUFACTURER AND
UL LISTED ASSEMBLY NUMBER AT EACH LOCATION WHERE THE FIRE STOPPING
SYSTEM IS INSTALLED.
Section A-A
A
A
VOLUME DAMPER DETAIL
SECTIONSIDE ELEVATION
DUCT
1/2" [15mm] ROUND
ROD PIN
INSULATION
STAND-OFF
HANDLE
WITH
LOCKING
QUADRANT
INSIDE END
BEARING
OUTSIDE END
BEARING
1/8" [6mm] CLEARANCE ALL
AROUND
DAMPER BLADE
INSULATION
NOTES:
1. DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.
2. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR
FOR MULTI-BLADE DAMPERS & ROUND DAMPERS.
2. DISCONNECT AND TRANSFORMER SHALL BE FACTORY MOUNTED
ADJACENT TO THE CONTROL PANEL.
3. FLEXIBLE DUCT SHALL NOT EXCEED 5 LINEAR FEET AND ONE 30° OR LESS
TURN PER SECTION.
(WIRING AND CONDUIT
PER ELECTRICAL
SPECIFICATIONS)
STRAINER
(TYPICAL)
NOTES
1. PROVIDE ORIFICE TYPE FLOW METER UPSTREAM OF PIPE FLOW AS
REQUIRED.
2. GATE VALVES SHOULD BE FULLY OPEN TO PROVIDE UNRESTRICTED FLOW.
3. PROVIDE PILOT OPERATED REGULATORS.
4. PROVIDE DRIP PAN ELBOW. OUTLET SIZE OF SRV-2A SHALL MATCH INLET OF
DRIP PAN ELBOW.
PRV-#
ENTERING
PRESSURE
(psi)
LEAVING
PRESSURE
(psi)
STEAM CAPACITY
(LBS/HR)
VALVE
SIZE
(in)
MODEL
PRESSURE REDUCING VALVES
PRV-1A 100 15 560 1/2"
HOFFMAN SERIES 2000
2100 FP
SRV-#
DISCHARGE
PRESSURE
(psi)
ACTUAL STEAM
FLOW (LBS/HR)
ORFICE
SIZE MODEL
SRV-1A 20 1,675 J
KUNKLE
6252 KJG
1 1/2"INLET/2 1/2" OUTLETPRV-1B 100 15 1115 1"
HOFFMAN SERIES 2000
2100 NP
PORT
TYPE
FULL
NORMAL
MEDIUM
PRESSURE
TRAP
PRV-1B
1 1/2"
2 1/2"
10 PIPE
DIAMETERS
MINIMUM
2 1/2"
PRESSURE
SENSING
LINES
REDUCED STEAM
PRESSURE SUPPLY
TO EQUIPMENT.
PITCH DN.
STEAM
SUPPLY
TO LPC
SAFETY RELIEF VALVE - SRV-1A
PRV-1A
1 1/2"
1 1/4"
2 1/2"
2"
1"
1 1/4"
NTS
PITCH
DOWN
PRESSURE REDUCING VALVE STATION SCHEDULE
SAFETY RELIEF VALVE
STRAINER
(TYPICAL)
NOTES :
1. THE GENERAL CONTRACTOR SHALL PROVIDE GASKETING AND DOOR SWEEPS ON DOORS
THAT COMMUNICATE WITH THE CORRIDOR IN ORDER TO MAINTAIN THE ABILITY TO MAINTAIN
ISOLATION ROOMS AT THE ESTABLISHED DIFFERENTIAL PRESSURE.
DPM
RESTROOM
ANTE
ROOM
SUPPLY AIR
VAV
ROOF MOUNTED ISOLATION
ROOM EXHAUST FAN
HEPA FILTERS
EXHAUST AIR
FROM ADDITIONAL
ISOLATION ROOMS
SEE NOTE 1SEE NOTE 3
SLIDING DOOR TO CORRIDOR SEE
NOTE 3
ISOLATION ROOM
FROM
AHU
NOTES:
1. PROVIDE SEISMIC RESTRAINTS AS REQUIRED BY
SEISMIC DETAIL SHEET.
2. SUPPORTS SHALL PENETRATE EXISTING ROOF SYSTEM.
PROVIDE ROOF PATCHING TO MATCH EXISTING.
LPCR
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000
Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/8
/2
:3
:2
A
M D
L o c a l R e v it
F ile s \3
C
E
C e n tr a l
M o d e l.
rv t
M002
MECHANICAL - DETAILS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
KAT
GAT
Salisbury, NC
100% FINAL DESIGN
11/10/16
NTS
2"
NTS
4"
8"
MIN.
NTS
MIN.
4"
NTS
NTS
NTS
NTS
NTS
DUCT
NTS
PREFABRICATED EQUIPMENT SUPPORT
GUY WIRE DETAIL
ROOF
WITH TURNBUCKLE
CABLE CLAMP
TURNBUCKLE
3/16" S/S GUY-WIRE
NOT TO SCALE
W/ SUNSHIELD
FLEX CONNECTION
MINIMUM
HIGH
10'-0"
GUY
WIRE (TYP. OF 3)
REFER TO
DETAIL
SEE NOTE 3.
SIDE ACCESS FILTER
HOUSING SUITABLE FOR
30% FLAT FILTER
99.9% HEPA FILTER
FLOW
AIR
MAGNAHELICS
LIQUID TIGHT.
DUCTWORK TO BE
WATER TIGHT
SEAL
BAG-IN/BAG-OUT SERVICE
EQUIPMENT
RAILS 6" WIDE,
14" HIGH
NOTES :
1. FAN SHALL HAVE SENSOR TO AFFIRM AIRFLOW. UPON DISRUPTION OF AIRFLOW, SENSOR SHALL SEND ALARM SIGNAL TO ALARM PANEL AT CENTRAL LOCATION STATION. HEPA FILTER ASSEMBLY
SHALL HAVE PRESSURE DIFFERENTIAL PORTS AND GAUGE TO MEASURE PRESSURE DROP ACROSS FILTERS. PRESSURE GAUGE SHALL BE MOUNTED ON FAN/FILTER ASSEMBLY IN WEATHERPROOF
HOUSING.
2. SEE FILTER SCHEDULE FOR FILTER SIZE AND DETAIL INFO.
3. THE DIAMETER OF STACK SHALL BE EQUAL TO THE FAN INLET SIZE FROM THE EXHAUST SYSTEM.
4. DUCTWORK EXPOSED TO THE ELEMENTS SHALL BE STAINLESS STEEL.
5. PROVIDE DRAIN PLUG IN EXHAUST FAN HOUSING.
SEE PLANS FOR CONT.
OF DUCTWORK
ROOF MOUNTED EXHAUST WITH HEPA FILTER BANK
6"
SLOPE FOR DRAIN
VIBRATION
ELIMINATOR CO.
TYPE "UN-S"
HOUSED SPRING
BASE DEFLECTION =
.75" MAX
PREFABRICATED ROOF CURB
SHEET METAL
COUNTER FLASHING
DUCT THRU ROOF
SHEET METAL SCREWS
WITH ROOFING CONTRACTOR.
COORDINATE COUNTER FLASHING
TREATED WOOD NAILER
CADMIUM PLATED
MASTIC
SEAL DUCT WITH WATERPROOF
SCREWS AT ALL CORNERS)
FLASHING (SHEET METAL
SLIP FIT OVER COUNTER
WEATHERPROOFING
INSULATION AND
PREFAB ROOF CURB
BY MECHANICAL
CONTRACTOR
FOR SIZE
DUCT-SEE PLAN
4"
DUCT
DRIP PAN ELL
FROM
PROTECTED
PRESSURIZED
EQUIPMENT
PRESSURE RELIEF
VALVE, SIZE AS
REQUIRED PER CODE
3/4" DRAIN, PIPE TO NEAREST
FLOOR DRAIN
DRIP PAN ELL
VENT PIPE, SIZE AS
REQUIRED PER CODE
FLOAT AND THERMOSTATIC (F&T) TRAP ASSEMBLY
FLOAT AND THERMOSTATIC
TRAP (SEE PLANS AND
SCHEDULES FOR SIZES)
1/2" TEST VALVE
STEAM SUPPLY
1/2" DRAIN VALVE
FULL SIZE DIRT LEG
STRAINER
UNION
GATE VALVE
NOTES:
1. USE ON LOW PRESSURE APPLICATIONS.
CONDENSATE
RETURN
MINIMUM 3/4" TRAP
SIZE
BUCKET TRAP ASSEMBLY
BUCKET TYPE
TRAP (SEE
PLANS AND
SCHEDULES
FOR SIZE)
1/2" TEST VALVE
CHECK VALVE
4" MIN.
STEAM SUPPLY
GATE VALVE
UNION
STRAINER
CONDENSATE
RETURN
DIRT LEG
FULL SIZE
FAN
CONCEALED HORIZONTAL FAN COIL UNIT
FINISHED
CEILING DRAIN PAN &
PIPE
CONNECTION
SUPPLY
AIR DUCT
OUTSIDE AIR DUCT.
SEE SCHEDULE
FOR SIZE.
RETURN
AIR GRILLE
& FILTER
HANGER ROD
SUPPORTS SECURE
TO STRUCTURE
ABOVE (TYP)
HINGED
BOTTOM
RETURN
AIR PANEL
EXTENSION
KIT AS
REQUIRED
CONNECTION TO FAN COIL UNIT - PIPING DETAIL
NEW 2-WAY PNEUMATIC
CONTROL VALVE
COPPER PIPING
CH
WS
D
CH
WR
AUTOMATIC FLOW
CONTROL VALVE SET AT
GPM FOR UNIT.
UNION (TYPICAL)
PVC PIPING
FAN COIL UNIT
NOTES:
1. PIPE SIZE SHALL BE AS SHOWN ON PLANS.
2. MAXIMUM PRESSURE DROP THROUGH VALVES SHALL BE 2 PSI.
3. THE CONTRACTOR SHALL FURNISH A CONTROL VALVE WHICH FITS INSIDE THE
FCU HOUSING AND IS SMALL ENOUGH TO ALLOW PROPER MAINTENANCE,
INCLUDING DIAPHRAGM REPLACEMENT, WITHOUT REMOVING OTHER PIPING
WITHIN THE FCU. THE PIPING CONFIGURATION WITHIN THE FCU SHALL ENSURE
THAT VALVES AND FITTINGS ARE POSITIONED ABOVE THE AUXILIARY DRAIN
PAN. THE CONTRACTOR SHALL INSTALL A FCU MOCK UP FOR APPROVAL BY
THE CONTRACTOR.
12" LENGTH OF
BRAIDED SIS
FLEXIBLE PIPE
INTEGRAL
CONDENSATE
PUMP
GLYCOL CHILLED WATER LOOP SCHEMATIC
GLYCOL COOLING
COIL LOCATED IN AHU
COLD WATER FILL WITH
BACKFLOW FROM
GLYCOL FILL UNIT
EXPANSION TANK
AIR SEPARATOR
BUFFER TANK
AIR COOLED
CHILLER
GCHWP-1
GCHWP-2
P P F T
T P
DUCT SUPPORT ABOVE ROOF
(TYPICAL)
GALVANIZED STRAP
2" DUCT
INSULATION WITH
ALUMINUM JACKET
COORDINATE DUCTWORK
WITH INLET OF FAN(S) ON
ROOF.
B-LINE B32 CHANNEL
1-3/8" x 1-5/8" FRAME
OR EQUAL
5 2
CONCRETE
DECK
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000
Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/8
/2
:3
:2
A
M D
L o c a l R e v it
F ile s \3
C
E
C e n tr a l
M o d e l.
rv t
M002A
MECHANICAL - DETAILS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
KAT
GAT
Salisbury, NC
100% FINAL DESIGN
11/10/16
PIPING & DUCT COMPONENT IMPORTANCE FACTOR (Ip) DESIGNATION
Ip = 1.0 Ip = 1.5
PIPING & DUCT VIBRATION ISOLATION REQUIREMENTS
SEISMIC AND WIND REQUIREMENTS FOR MECHANICAL SYSTEMS (ASCE 7-05)
COMPONENT IMPORTANCE FACTOR (IP)
COMPONENT IDENTIFICATION
ROOF MOUNTED NOT REQUIRED RESTRAIN ALL 13.1.4.3
FLOOR MOUNTED
WALL MOUNTED
COMPONENT SUPPORTS 13.1.4.3 13.6.5
NOT REQUIRED 13.1.4.3
RESTRAIN IF >75 LBS
(SEE NOTE 3)
PROVIDE FLEX. CONN.
(SEE NOTE 4)
13.6.7
NOT REQUIRED 13.1.4.3 RESTRAIN ALL 13.1.4.3
13.1.4.3 >2"
(SEE NOTES 5,6) 13.6.8.2.b
13.1.4.3
RESTRAIN ALL
(SEE NOTE 6) 13.1.4.3
13.2.2 REQUIRED 13.2.2
SEISMIC DESIGN CATEGORIES D,E,F
COMPONENT IMPORTANCE FACTOR (IP)
COMPONENT IDENTIFICATION
SEISMIC RESTRAINT
REQUIREMENT
ASCE
7-05
REFERENCE
SEISMIC RESTRAINT
REQUIREMENT
ROOF MOUNTED
RESTRAIN ALL
(SEE NOTE 1) 13.1.4.3 RESTRAIN ALL 13.1.4.3
FLOOR MOUNTED
RESTRAIN ALL
(SEE NOTES 1,2) 13.1.4.3 RESTRAIN ALL 13.1.4.3
WALL MOUNTED
RESTRAIN ALL
(SEE NOTE 1) 13.1.4.3 RESTRAIN ALL 13.1.4.3
COMPONENT SUPPORTS
RESTRAIN ALL
(SEE NOTE 1) 13.6.5 RESTRAIN ALL 13.6.5
SUSPENDED
EQUIPMENT
INLINE W/ DUCT
RESTRAIN IF >75 LBS
(SEE NOTE 3)
PROVIDE FLEX. CONN.
(SEE NOTE 4)
13.6.7
RESTRAIN IF >75 LBS
(SEE NOTE 3)
PROVIDE FLEX. CONN.
(SEE NOTE 4)
13.6.7
NOT INLINE W/
DUCT/PIPE
RESTRAIN ALL
(SEE NOTE 1) 13.1.4.3 RESTRAIN ALL 13.1.4.3
SUSPENDED DUCTILE PIPING
>3"
(SEE NOTES 5,6) 13.6.8.2.c >1"
(SEE NOTES 5,6) 13.6.8.2.a
SUSPENDED DUCTWORK
6 SQ.FT. AND LARGER
(SEE NOTE 6) 13.1.4.3
RESTRAIN ALL
(SEE NOTE 6) 13.1.4.3
COMPONENT
CERTIFICATION
(SEE NOTE 7)
NOT REQUIRED 13.2.2 REQUIRED 13.2.2
1.0 1.5
ASCE
7-05
REFERENCE
13.1.4.3
13.1.4.3
RESTRAIN ALL
RESTRAIN ALL
RESTRAIN ALL
13.1.4.3
13.1.4.3
13.1.4.3
SEISMIC RESTRAINT
REQUIREMENT
ASCE
7-05
REFERENCE
SEISMIC RESTRAINT
REQUIREMENT
ASCE
7-05
REFERENCE
1.0 1.5
SUSPENDED
EQUIPMENT
INLINE W/ DUCT
NOT INLINE W/
DUCT/PIPE
SUSPENDED DUCTILE PIPING
SUSPENDED DUCTWORK
COMPONENT
CERTIFICATION
(SEE NOTE 7)
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
SEISMIC DESIGN CATEGORY C
I. ALL ROOF CURBS / ROOF RAILS INCLUDING THEIR ATTACHMENT TO THE EQUIPMENT AND STRUCTURE MUST BE EVALUATED FOR WIND LOADING. WHERE SEISMIC RESTRAINT IS REQUIRED, THE MORE
DEMANDING FORCE OF WIND AND SEISMIC MUST BE USED.
II. SEE SEISMIC INFORMATION CONTAINED IN THE STRUCTURAL DRAWINGS FOR SITE SPECIFIC
INFORMATION ON SEISMIC DESIGN CATEGORY.
III. SEE EQUIPMENT SCHEDULES AND DETAILS FOR SPECIFIC COMPONENT IMPORTANCE FACTOR
DESIGNATIONS.
IV. USE APPLICABLE TABLE BELOW TO DETERMINE SEISMIC RESTRAINT REQUIREMENTS FOR EACH
MECHANICAL COMPONENT.
V. FOR ALL COMPONENTS REQUIRING SEISMIC RESTRAINT, THE COMPONENT SUPPORTS AND
ATTACHMENTS SHALL BE DESIGNED BY A REGISTERED DESIGN PROFESSIONAL.
VI. WHERE SEISMIC RESTRAINT IS REQUIRED, HOUSEKEEPING PADS NEEDED FOR THE INSTALLATION OF EQUIPMENT UNDER THIS CONTRACT MUST BE DESIGNED BY THE SEISMIC ENGINEER. DO NOT POUR ANY
HOUSEKEEPING PADS PRIOR TO THE THE RECEIPT OF THE SEISMIC SUBMITTAL.
NOTES:
1. EQUIPMENT 20 LBS. OR LESS IS EXEMPT IF FLEXIBLE CONNECTIONS ARE PROVIDED BETWEEN
THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT.
2. RESTRAINTS ARE NOT REQUIRED IF THE COMPONENT WEIGHS 400 LBS. OR LESS, IS MOUNTED
AT 4 FT. OR LESS ABOVE A FLOOR, AND HAS FLEXIBLE CONNECTIONS BETWEEN THE
COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT.
3. ITEMS WEIGHING LESS THAN 76 LBS. DO NOT NEED RESTRAINT IF THE ATTACHED DUCTWORK IS
RESTRAINED AND POSITIVELY ATTACHED TO THE EQUIPMENT.
4. FLEXIBLE CONNECTIONS REQUIRED FOR PIPE CONNECTIONS ONLY.
5. ALL NON-DUCTILE PIPING (PLASTIC, CAST IRON, CERAMIC) MUST BE RESTRAINED.
6. RESTRAINT IS NOT REQUIRED IF SUSPENDED 12" OR LESS FROM THE STRUCTURE AND THE
HANGERS ARE DETAILED TO AVOID SIGNIFICANT BENDING OF THE HANGERS AND THEIR
ATTACHMENTS AND PROVISIONS ARE MADE FOR PIPING TO ACCOMMODATE EXPECTED DEFLECTIONS.
7. COMPONENT CERTIFICATION MUST BE SUPPLIED BY THE EQUIPMENT MANUFACTURER AT TIME OF
SUBMITTAL FOR REVIEW BY ENGINEER OF RECORD & SEISMIC DESIGNER.
REFER TO STRUCTURAL OR ARCHITECTURAL DRAWINGS FOR SEISMIC DESIGN CATEGORY.
TYPE 1 ISOLATION
GASKET
CURB
MOUNTED
EQUIPMENT
WOOD NAILER
COUNTERFLASHING
ROOF MEMBRANE
CANT. PIECE
ROOF BALLAST
WOOD NAILER
ROOF INSULATION
3 LB. HEAVY DENSITY
FIBERGLASS INSUL.
ATTACH CURB TO
STRUCTURE PER SEISMIC
AND/OR WIND RESTRAINT
SUBMITTALS
WIND/SEISMIC RATED
ROOF CURB
(SEE NOTE BELOW)
ALL ROOF CURBS, THEIR ATTACHMENT
TO STRUCTURE & THE UNIT
ATTACHMENT TO THE CURB MUST BE
EVALUATED FOR WIND LOADING.
WHERE SEISMIC RESTRAINT IS
REQUIRED, THE MORE DEMANDING
FORCE OF WIND & SEISMIC MUST BE
USED.
ATTACH UNIT TO ROOF CURB
PER SEISMIC AND/OR WIND
LOADING REQUIREMENTS
TYPE 2 ISOLATION
TYPE 3 ISOLATION (FLOOR MOUNTED)
TYPE 3 ISOLATION (SUSPENDED)
TYPE 4 ISOLATION
TYPE 'B' ISOLATION
• ALL DUCT
• HOT WATER SUPPLY & RETURN
• STEAM SUPPLY AND CONDENSATE PIPING
• ALL EQUIPMENT
• CHILLED WATER SUPPLY & RETURN
TYPE 5 ISOLATION
NON ISOLATION ROOF CURB
TYPE 'D' ISOLATION (ROOF CURB)
A. SUPPORT PIPING CONNECTIONS TO EQUIPMENT MOUNTED ON SPRING ISOLATORS USING TYPE 3 ISOLATORS FOR SCHEDULED DISTANCE.
1. UP TO 4 INCHES PIPE SIZE: FIRST THREE POINTS OF SUPPORT.
2. 5 TO 8 INCHES PIPE SIZE: FIRST FOUR POINTS OF SUPPORT.
3. 10 INCHES PIPE SIZE AND OVER: FIRST SIX POINTS OF SUPPORT.
4. SELECT THREE HANGERS CLOSEST TO VIBRATION SOURCE FOR MINIMUM 1.0 INCH STATIC DEFLECTION OR STATIC DEFLECTION OF ISOLATED EQUIPMENT. SELECT REMAINING ISOLATORS FOR MINIMUM 1.0 INCH STATIC DEFLECTION OR 1/2 STATIC DEFLECTION OF ISOLATED EQUIPMENT.
5. FLEXIBLE CONNECTIONS SHOULD BE PROVIDED FOR ALL PIPING CONNECTIONS TO VIBRATION ISOLATED EQUIPMENT.
BUILDING
STRUCTURE
NRC
MAXIFLEX
NK
BRD
RHD
HD
SW
SERIES A
SLF
BSRA
RSH-30A
30N
MS
AWRS
SLR
SWSR
ASCM
SLRA
TRK
SFB/WSB
WFB
WF
A/B:
VMC:
MASON:
RTIC
P-6200
RSC
IM:
VMC:
WLRC
P-6000
ANCHOR BOLT
MOTOR
END
PUMP END
OPER. CL.
EQUIPMENT MOUNTING HOLES
ISOLATOR
(4) MIN. REQ'D
HEIGHT SAVING
BRACKET (TYP.)
STEEL ISOLATION BASE
RUBBER IN SHEAR
ELEMENT
30°
SPRING & RUBBER HANGER
FOR 15° MISALIGNMENT (30° SWING)
HANGER ROD TO
SUPPORT STRUCTURE
EQUIPMENT
MOUNTING FOOT
GROMMET LOAD PLATE
1" PAD WITH HOLE. PLATE TO BE
PROVIDED IF EQUIPMENT FOOT
COVERS LESS THAN 80% OF PAD.
ANCHOR
PAD TYPE ISOLATOR
RUBBER-IN-SHEAR HANGER
HANGER ROD TO
SUPPORT STRUCTURE
RUBBER IN SHEAR
ELEMENT
A/B:
A/B:
VMC:
MASON:
A/B:
VMC:
MASON:
A/B:
VMC:
MASON:
A/B:
VMC:
MASON:
A/B:
VMC:
MASON:
A/B:
VMC:
MASON:
A/B:
VMC:
MASON:
ADJUSTING BOLT
ELASTOMERIC BUSHING
JAM NUT
1_
" THICK RIBBED
NEOPRENE PAD
ROOF DECK
ROOF
INSULATION
WATERPROOF
MEMBRANE
2" THICK
INSULATIONBOARD
FLATTENED
EXPANDED METAL
MESH - 1/2 NO. 16
LOWER FLASHING
FIELD INSTALLED
TO WOOD NAILER
12" WIDE RUBBER GASKET TO ENCLOSE
ENTIRE OUTSIDE OF CURB AS SHOWN.
OVERLAP SEAMS AT LEAST 4".
2X2 NOMINAL
CCA40 TREATED
WOOD NAILER
ALL AROUND CURB
TYPE 3 ISOLATOR TO BE
USED FOR FOR
NON-SEISMIC OR WIND
APPLICATIONS.
TYPE 4 ISOLATOR TO BE
USED FOR SEISMIC OR
WIND APPLICATIONS.
ALL ROOF CURBS, THEIR ATTACHMENT TO
STRUCTURE & THE UNIT ATTACHMENT TO THE
CURB MUST BE EVALUATED FOR WIND LOADING.
WHERE SEISMIC RESTRAINT IS REQUIRED, THE
MORE DEMANDING FORCE OF WIND & SEISMIC
MUST BE USED.
STEEL SPRINGS TO
MATCH DEFLECTION
OF ISOLATION
BUILDING STRUCTURE
PRE-COMPRESSION NUT
THREADED ROD
STEEL ANGLES WITH
BACK-UP PLATES
NTS
NTS
NTS
NTS
NTS
NTSNTS
NTS NTS
NTS
9 6
ATTACH ROOF
MEMBRANE TO CURB
ROOF DECK
TYPE 'C' ISOLATION
ROOF RAIL DETAIL
WOOD NAILER
ROOF MEMBRANE
ROOF INSULATION
ROOF DECK
ATTACH ROOF MOUNTING
RAIL TO STRUCTURE PER
SEISMIC AND/OR WIND
RESTRAINT SUBMITTALS
ALL ROOF MOUNTING RAILS, THEIR ATTACHMENT TO
STRUCTURE & THE UNIT ATTACHMENT TO THE RAIL MUST BE
EVALUATED FOR WIND LOADING. WHERE SEISMIC RESTRAINT
IS REQUIRED, THE MORE
DEMANDING FORCE OF WIND & SEISMIC MUST BE USED.
BUILDING
STRUCTURE
CANT. PIECE
ATTACH UNIT TO ROOF
MOUNTING RAIL PER SEISMIC
AND/OR WIND LOADING
REQUIREMENTS
WIND/SEISMIC RATED
ROOF MOUNTING RAIL
(SEE NOTE BELOW)
CPF
MPF
BMK
WLRR
R-7000
REBAR
OPER. CL. ISOLATOR
(4) MIN. REQ'D
CONCRETE INERTIA BASE
WITH ISOLATORS
IM:
VMC:
A/B:
VMC:
MASON:
VIBRATION ISOLATION TYPES PER ASHRAE HANDBOOK - HVAC APPLICATIONS CHAPTER 47
TYPE 3 ISOLATOR
TO BE USED FOR
FOR NON-SEISMIC
APPLICATIONS.
TYPE 4 ISOLATOR
TO BE USED FOR
SEISMIC
APPLICATIONS.
NTS
ATTACH ROOF
MEMBRANE
TO ROOF RAIL
NAILER
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000
Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/8
/2
:3
:2
A
M D
L o c a l R e v it
F ile s \3
C
E
C e n tr a l
M o d e l.
rv t
M003
MECHANICAL - SEISMIC
DETAILS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
KAT
GAT
Salisbury, NC
100% FINAL DESIGN
11/10/16
NOTES:
2. PROVIDE ISOLATION VALVES AND CHECK VALVES FOR EACH PUMP.
1. MOTORS SHALL BE INVERTER DUTY PREMIUM EFFICIENCY.
1. PROPYLENE GLYCOL SHALL BE USED.
2. 5 YEAR PARTS AND LABOR WARRANTY.
3. HAIL GUARDS ON THE CONDENSER COILS SHALL BE PROVIDED.
4. STARTUP BY FACTORY TECH.
5. FACTORY PERFORMANCE TEST.
3. FACTORY MOUNTED, WIRED AND CONTROLLED VFD SHALL BE PROVIDED
4. PROVIDE SENSOR MONITOR TANK FOR GLYCOL/WATER MIXTURE VERIFICATION.
5. PUMPS AND TANKS SHALL BE MOUNTED UNDER AIR COOLED CHILLER FRAMING/COVER.
6. CHILLER EQUIPMENT DE-RATED FOR 20% PROPYLENE GLYCOL
SOLUTION.
7. DISCONNECT SWITCHES PROVIDED BY THE ELECTRICAL CONTRACTOR.
NOTES
52.00 180 160
52.00 180 149
5-E-1C 360 360 8 8 100.00 0.17 2.23 23.40 0.95 5008A - 1, 5008B - 2, 5008C - 3
5-E-2C 310 310 6 6 0.20 1.14 16.70 0.25 5010 - ISOLATION, 5010A - ANTE
310 100.00
3/4"
3/4"
CFM
CFM
CFM
CFM
100 42 32 180.40 47.90 ft H20 100ACCH-1 500.00 208 3 4 8 TRANE CGAM 100474.70
ACCH-2 100 42 32 180.40 47.90 ft H20 100 500.00 208 3 4 8 TRANE CGAM 100474.70
GCWP-1 ACCH-1 ACCH-1 180 91.19 15HP 208V/3Ø/28A CENTRIFUGAL HIGH HEAD MECHANICAL 6.3 201VFD
GCWP-2 ACCH-2 ACCH-2 180 91.19 15HP 208V/3Ø/28A CENTRIFUGAL HIGH HEAD MECHANICAL 6.3 201VFD
52.00 180 1694-11-4C 530 530 6 6 100.00 0.54 5.43 28.60 3.67 4010 - STERILE SUPPLY, 4012 - CORRIDOR, 4017A - STORAGE2530 3/4"
52.00 180 1304-11-3C 1,855 1,855 14 14 90.00 0.44 3.28 79.10 1.58 4008 - OR #121,855 1"
52.00 180 1274-11-2C 1,730 1,730 14 14 90.00 0.40 2.88 73.80 1.27 4006 - OR #221,730 1"
52.00 180 1604-11-1V 295 150 8 8 100.00 0.06 0.75 7.30 0.38 4003 - CYSTO STORAGE, 4005 - EQ STORAGE1150 3/4"
52.00 180 1635-4-4V 560 280 10 10 100.00 0.10 1.89 15.10 2.17 5077B - ELEVATOR LOBBY, 5087 - CLEAN CORE1280 1"
52.00 180 1335-4-2C-B 1,955 1,955 14 14 90.00 0.49 3.63 83.40 1.88 5084 - SEMI-HYBRID 1, 5085 - EQ STORAGE21,955 1"
52.00 180 1315-4-2C-A 1,865 1,865 14 14 90.00 0.45 3.32 79.60 1.61 5084 - SEMI-HYBRID 121,865 1"
52.00 180 1614-11-5V 525 265 10 10 100.00 0.09 1.58 14.30 1.64 4009 - CLEAN CORE1265 3/4"
4-11-6V
52.00 180 1605-11-1C-A 2,500 2,500 16 16 90.00 0.69 10.2 102.6 5.04 5001 - HYBRID 222,500 1 1/4"
52.00 180 1605-11-1C-B 2,240 2,240 16 16 90.00 0.73 9.7 97.0 5.91 5001 - HYBRID 222,240 1 1/4"
52.00 180 1605-11-2V 490 245 8 8 100.00 0.16 1.15 11.20 0.74 5003 - MECH, 5007 - EQ STORAGE, 5078 - CORRIDOR, 5094 - SCRUB, 5078 - CORRIDOR1245 3/4"
52.00 180 1605-11-3C 765 765 10 10 100.00 0.32 3.53 43.10 2.58 5077 - NS WORK, 5086 - SCRUB, 5090 - M LOCKERS, 5091 - STERILE SUPPLY, 5092 - F LOCKERS, 5078 - CORRIDOR2765 3/4"
PUMPS PROVIDED BY ACCH MFG.
ELECTRICAL CHARACTERISTICS
VOLT/PHASE/AMPS
PUMPS PROVIDED BY ACCH MFG.
FLOW CONTROL REMARKS AND MFG. TYPE
DESIGN BASED ON
BUFFER TANK
VOLUME (gal)
EXPANSION TANK
VOLUME (gal)TYPE SEALTYPE PUMPMIN. H.P. &
VOLTAGEFEET HEADGPM MIN.LOCATIONSERVICESPUMP NO.
NOTES
MANUFACTURER
& MODEL
CONDENSER
FANSCOMPRESSORS
PH.VOLTSMOCPMCA
ELECTRICALO.A.
TEMP
(°F)
MAX. WATER
PRESS. DROP
(EVAPORATOR)
GPML.W.T.
(°F) E.W.T.
(°F)
CAPACITY
(TONS)UNIT NO.
PRICE LFD24"x12" 6" RND NECK0-60
PRICE LFD24"x48" 10" RND NECK0-280
OVERALL
DIMENSIONS
24"x24"INLET
DIMENSIONS
10"x6"
4. ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE
ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
5. LAMINAR DIFFUSERS SHALL BE PROVIDED WITH OUT HEPA FILTER ACCESSORY.
AND SHALL BE PROVIDED WITH STAINLESS STEEL MANUAL VOLUME DAMPER OPTION FOR AIRFLOW
BALANCING.
NOTES
1. HORD SYSTEM (92STSYS) SHALL BE CONSTRUCTED WITH CONTINUOUSLY WELDED
STAINLESS STEEL.
2. PLENUM FRAME AND DIFFUSER FINISH SHALL BE COORDINATED WITH ARCH.
TAG OVERALL
DIMENSIONS TYPE
196"x192"0-240
CFM RANGE
PRICE HORD
PRICE LFD6" RND NECK0-120
TAG NECK TYPECFM RANGE
REHEAT
ROWS
WATER
RUNOUT
SIZE
UNIT SIZE AIR RUNOUT
SIZE ROOM NUMBER AND NAME
MIN.MAX.
WATER
PRESSURE
DROP(FT)
L.W.T.
(°F)
E.W.T.
(°F)MBHGPM
MINIMUM
OPERATING
PD (in.wg)
HEATING
L.A.T.
(°F)
E.A.T.
(°F)
CFMTERMINAL
NO.
7. CONSTANT VOLUME BOXES SHALL BE THE SAME BOX USED FOR VARIABLE VOLUME BOX
EXCEPT CFM SHALL BE LOCKED AT CAPACITY SHOWN. BOX SHALL NOT OPERATE AS
VARIABLE VOLUME.
8. CONTROLS SHALL BE DDC PROVIDED BY CONTROLS CONTRACTOR AND INSTALLED BY BOX
MANUFACTURER.
9. BASIS OF DESIGN SHALL BE PRICE SINGLE DUCT VARIABLE OR CONSTANT VOLUME SDV
SERIES. APPROVED EQUALS: KREUGER, ENVIRO-TEC, & NAILOR.
10. MAXIMUM NC LEVEL OF 30 ON ALL BOXES. PROVIDE SOUND ATTENUATOR AS REQUIRED.
11. PROVIDE DIFFERENTIAL AIRFLOW SWITCH.
12. TERMINAL UNITS SERVING THE OPERATING SUITE SHALL BE 2-POSITION CONSTANT AIR VOLUME
GENERAL NOTES
1. BOXES SHALL HAVE PIPE CONNECTIONS ON SAME SIDE AND BE FOR FLARED FITTINGS.
2. COIL AND BOX SIZE MAY BE INCREASED TO MEET REQUIRED CONDITIONS; BUT SHALL NOT BE
DECREASED FROM SIZE SHOWN.
3. BOXES SHALL BE SET FOR MAXIMUM CFM SHOWN ON PLANS.
4. DUCT CONNECTIONS TO BOXES SHALL BE SAME SIZE AS BOX INLET UNLESS SHOWN
OTHERWISE.
5. MAXIMUM WATER PRESSURE DROP SHALL BE 6 FEET.
6. VARIABLE VOLUME BOXES SHALL OPERATE DOWN TO 50% OF MAXIMUM FLOW.
52.00 180 1605-E-3V 420 210 8 8 0.16 1.14 11.10 0.73 5070 - NURSE MANAGER, 5072 - ANESTH OFFICE, 5073 - ANESHT WORK/SUPPLY, 5075 STRETCHER ALCOVE, 5076 - EQ ALCOVE, 5078 - CORRIDOR1210 100.00 3/4"
BANK
No.
DESIGN BASIS
MODEL NO.
SIZE EACHTOTAL
CFMLOCATION NO. OF
FILTERS FILTER
PRE-FILTER
STATIC PRESSURE
INITIAL
MAX.
FINAL
MAX.
TYPE
EFF.
MIN.
STATIC PRESSUREDESIGN BASIS
MODEL NO.
MFG. & NO. OF
FILTERS
SIZE EACH
FILTER
INITIAL
MAX.
FINAL FILTER
FINAL
MAX.
TYPE MIN.
EFF.
MFG. &
REMARKS:
PROVIDE CAMFIL STAINLESS STEEL CONTAINMENT HOUSING, SEPARATE ACCESS DOORS FOR PREFILTER AND HEPA FILTER, MAGNEHELIC GAUGE AND WEATHER CAP. BASIS OF DESIGN IS CAMFIL MODEL CF-1X1-212P-3GB-SS (FB-1A, 1B, 2A, 2B ONLY).1.
FB-1 ROOF 635 1 24x24x2 0.05 0.2 30% 1 24X24X12 0.5 1.0 HEPA 99.97%THROW
AWAY
CAMFIL
30/30 CAMFIL FB BIOLOGICAL GRADE HEPA FILTER CARTRIDGE
WITH FACEGUARD, 99.97% EFFICIENT
FB-2 ROOF 635 1 24x24x2 0.05 0.2 30% 1 24X24X12 0.5 1.0 HEPA 99.97%THROW
AWAY
CAMFIL
30/30 CAMFIL FB BIOLOGICAL GRADE HEPA FILTER CARTRIDGE
WITH FACEGUARD, 99.97% EFFICIENT
SERVICES LOCATION CFM STARTER DISC. SW.
EF-1
FAN NO. FAN RPM
EXTERNAL
STATIC PRESS.
IN W.G. FAN WHEEL TYPE
MOTOR
HP/VOLT/PHASE
DRIVE
TYPE FAN TYPE CONTROL SWITCH &
INTERLOCK TYPE MFG. & MODEL # DESIGN BASED ON
EF-2
5010 - ISOLATION ROOF 635 3,204 3.75 BELT CENTRIFUGAL UTILITY SET VFD GREENHECK 9-CSW-BI-21-10-I-10 VFD MC
MC
BACKWARD INCLINED
NOTES:
1. PROVIDE VIBRATION ISOLATORS, SEE SPECIFICATIONS.
2. COORDINATE HEIGHT OF ROOF CURB WITH ROOFING CONTRACTOR.
3. APPROVED EQUALS - COOK AND TWIN CITY.
4. PROVIDE VARIABLE SPEED DRIVES ON ISOLATION ROOM FANS TO COMPENSATE FOR VARYING PRESSURE DROP ACROSS HEPA FILTERS (ISOLATION ROOM EXHAUST FANS ONLY).
5. ISOLATION EXHAUST FANS MAY SUPPLY MORE CAPACITY THAN SHOWN ON AIR DISTRIBUTION.
6. MOTORS SHALL BE INVERTER DUTY PREMIUM EFFICIENCY.
1/208/3Ø
5010 - ISOLATION ROOF 635 3,204 3.75 BELT CENTRIFUGAL UTILITY SET VFD GREENHECK 9-CSW-BI-21-10-I-10 VFDBACKWARD INCLINED 1/208/3Ø
MAX RPM
1,780
1,780
BOXES FOR OCCUPIED AND UN-OCCUPIED OPERATIONS.
7. TERMINAL UNITS PROVIDED SERVING THE SUGERY SUITE SHALL BE PROVIDED WITH COPPER FINS AND COPPER TUBES.
52.00 N/A N/A4-11-7V 200 0 6 6 52.00 0.01 N/A N/A N/A 4015 - ELECTRICALN/AN/A N/A
5-E-4V 52.00 180 160300 150 8 8 100.00 0.06 0.75 7.30 0.38 5108 - CORRIDOR, 5106 - CLEAN/MEDS, 5107 - N/S1150 3/4"
72.70
72.70
NOT USED
CFM
PRICE HORD0-290 160x120" 10"x6"
ACTUAL
CAPACITY
(TONS)
52.00 180 1605-11-4V 400 200 8 8 100.00 0.16 1.15 10.4 1.04 5077 - NS WORK, 5086 - SCRUB, 5090 - M LOCKERS, 5091 - STERILE SUPPLY, 5092 - F LOCKERS, 5078 - CORRIDOR1200 3/4"
52.00 N/A N/A5-11-5V 550 0 10 10 52 0.01 N/A N/A N/A 5002 - EQN/A0 N/A
5-11-6V 200 0 52.00 N/A N/A6 6 52 0.01 N/A N/A N/A 5005 - ELECN/A0 N/A
CFM 0-200 8" RND NECK24"x36" PRICE LFD
TERMINAL UNIT SCHEDULE
LAMINAR DIFFUSERS
AIR CURTAIN
AIR COOLED WATER CHILLER SCHEDULE
GLYCOL CHILLED WATER PUMP SCHEDULE
FILTER BANK SCHEDULE
FAN SCHEDULE
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000 Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road Suite 500 Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/2
0/
:5 8:
P
M E
:\L oc al R ev it
Fi le s\
\3
C E
- C en tra l
M od el .rv t
M004
MECHANICAL -
SCHEDULES
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
KAT
GAT
Salisbury, NC
100% FINAL DESIGN
11/10/16
Item Date Description
2 10/31/17 Revision 2 - Hybrid 2
1. PROVIDE SUPPORT LEGS.
2. PROVIDE 3/4" THICK RIGID INSULATION KIT.
3. OUTDOOR STEAM TO STEAM GENERATOR SHALL BE PROVIDED WITH THE FOLLOWING ACCESSORIES:
INSULATED HEADERS, INSULATED TUBES, ELECTRONIC DRAIN WATER COOLER, SHORT ABSOPTION STEAM MANIFOLD, MOUNTING FRAME
FOR HEADERS AND INLET ADAPTOR KIT.
4. PROVIDE ROOF CURB TO SUPPORT EQUIPMENT ON ROOF.
5. DISCONNECT SWITCH SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR.
1. PROVIDE INTEGRAL CONDENSATE COOLER.
2. PROVIDE SHORT ABSORPTION MANIFOLDS. REFER TO DUCTWORK PLANS FOR MANIFOLD LOCATION AND SUPPLY DUCTWORK DIMENSIONS.
UNIT NO. CAPACITY
(MBH)
CHILLED WATER SIDE GLYCOL CHILLED SIDE
E.W.T. L.W.T GPM MAX.
P.D. E.W.T. L.W.T. GPM MAX.
P.D.
SQUARE
FEET
NUMBER
OF PLATES
BASIS OF DESIGN MANUFACTURER
AND MODEL NUMBER
PF-1 1,254 44 54 250 4.5 34 41 8.98 145 58 SONDEX-S21A360
NOTES
1. BASIS OF DESIGN SHALL HAVE A MAX WORKING/TEST PRESSURE RATING OF 150PSI.
2. GYLCOL CHILLED WATER SHALL BE A 20% PROPYLENE SOLUTION.
UNIT WEIGHT: (LBS)
SYSTEM DESCRIPTION
OUTDOOR UNIT ELECT. CONN. MCA/MOCP
ELECTRICAL CHARACTERISTICS
COOLING EDB/EWB (°F)
GROSS COOLING CAP (MBH)
TOTAL CFM
UNIT MODEL NUMBER:
MANUFACTURER
UNIT TAG:
SEER
FAN MOTOR FLA
SPLIT SYSTEM
13/20
1,200
15.3
0.35
PUY-A18NHA4
SSCU-1
95/75
SPLIT SYSTEM
N/A
MITSUBISHI
15.3
0.33
SSEU-1
80/67
PKA-A18HA4
SEE NOTE 2
MITSUBISHI
3. APPROVED EQUALS - DAIKEN AND CARRIER.
LOCATION ROOF
CONDENSING UNIT EVAPORATOR UNIT
ELEVATOR EQUIPMENT
ROOM
208/1Ø
COOLING ONLY COOLING ONLY
AV-1
AV-2
1,360 1,360 EXHAUST 10 OR-1 4008 4TH FLOOR
TAG MAXIMUM
CFM
MINIMUM
CFM
AIR FLOW
TYPE
UNIT
SIZE SERVES LOCATION
AV-3
AV-4
AV-5
INLET
SIZE
10"
NOTES
1. BASIS OF DESIGN: CRC.
2. UNITS SERVING OR SPACES SHALL BE VARIABLE VOLUME TO ENSURE POSITIVE PRESSURE CAN BE MAINTAINED.
3. EXHAUST AIR VALVES SHALL BE SUPPLY WITH A FAIL OPEN FAILSAFE OPTION.
AV-7
1,230 1,230 EXHAUST 10 OR-2 4006 4TH FLOOR10"
920 920 EXHAUST 10 SEMI HYBRID-1 5084 5TH FLOOR10"
920 920 EXHAUST 12 SEMI HYBRID-1 5084 5TH FLOOR12"
800 800 EXHAUST 12 HYBRID-2 5001 5TH FLOOR12"
1,650 1,650 EXHAUST 12 HYBRID-2 5001 5TH FLOOR12"
AV-6 1,650 1,650 EXHAUST 12 HYBRID-2 5001 5TH FLOOR12"260
H-1
H-2
AHU-11
AHU-4
STEAM
STEAM
75 110/1 0.65 15 NORTEC SETC B+ 100 N/A
TAG SERVICE TYPE CAPACITY
(LB./HR.) VOLTS/PHASE kW STEAM (PSI) MANUFACTURER & MODEL NO. REMARKS
H-3
H-4
H-5
H-6
H-7
4006 - OR #2
4008 - OR #1
5084 - SEMI - HYBRID 1
5084 - SEMI - HYBRID 1
5001 - HYBRID 2
ELECTRODE
ELECTRODE
ELECTRODE
ELECTRODE
ELECTRODE
208/1
208/1
208/3
208/3
208/3
3.70
3.70
7.50
7.50
7.50
30.00-80.00
30.00-80.00
30.00-80.00
30.00-80.00
30.00-80.00
NORTEC EL 010/208/1
NORTEC EL 010/208/1
NORTEC EL 020/208/3
NORTEC EL 020/208/3
NORTEC EL 020/208/3
N/A
N/A
N/A
N/A
N/A
TAG SERVICE TYPE CAPACITY
(LB./HR.) VOLTS/PHASE kW WATER (PSI) MANUFACTURER & MODEL NO. REMARKS
69 110/1 0.65 15 NORTEC SETC B+ 100 N/A
H-8 5001 - HYBRID 2 ELECTRODE 15 208/3 7.50 30.00-80.00 NORTEC EL 020/208/3 N/A
NOTES
NOTES
SYMBOL SIZE TYPE
111-250 CFM 10"x8"
0-110 CFM 8"x4"
251-480 CFM 14"x10"
481-650 CFM 18"x12"
651-835 CFM 20"x14"
836-1400 CFM 24"x18"
PRICE 530/630CFM
CFM
CFM
CFM
CFM
CFM
PRICE 530/630
PRICE 530/630
PRICE 530/630
PRICE 530/630
PRICE 530/630
ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER.
SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
226-450 CFM 12"x10"
0-225 CFM 10"x6"
451-700 CFM 18"x12"
701-900 CFM 24"x12"
901-1180 CFM 30"x12"
1181-1350 CFM 36"x12"
SYMBOL CFM RANGE & MODULE SIZE
ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER.
SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
CFM
CFM
CFM
CFM
CFM
CFM
PRICE 520/620
DOUBLE DEFLECTION
PRICE 520/620
DOUBLE DEFLECTION
PRICE 520/620
DOUBLE DEFLECTION
PRICE 520/620
DOUBLE DEFLECTION
PRICE 520/620
DOUBLE DEFLECTION
PRICE 520/620
DOUBLE DEFLECTION
TYPE
1401-1800 CFM 30"x18"CFM
7 PRICE 530/630
SPLIT SYSTEM
13/20
1,200
15.2
0.35
PUY-A12NHA4
SSCU-2
95/75
SPLIT SYSTEM
N/A
MITSUBISHI
15.2
0.33
SSEU-2
80/67
PKA-A12HA4
SEE NOTE 2
MITSUBISHI
ROOF IT ROOM 4019
CONDENSING…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.