36C24618R0842-003.pdf
PDF 13 MB Posted
- Attached to
- Project 659-16-101, Correct Operating Room Deficiencies Federal contract opportunity
- Solicitation number
- 36C24618R0842
About this file
36C24618R0842 CONTRACT ATTACHMENT A - DRAWINGS - FILE 2 - Architectural.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24618R0842-0002003.pdf | ||
| 36C24618R0842-0002001.pdf | ||
| 36C24618R0842-0002002.pdf | ||
| 36C24618R0842-0002000.docx | DOCX document | |
| 36C24618R0842-0002004.pdf | ||
| 36C24618R0842-004.pdf | ||
| 36C24618R0842-005.pdf | ||
| 36C24618R0842-008.docx | DOCX document | |
| 36C24618R0842-001.docx | DOCX document | |
| 36C24618R0842-009.pdf | ||
| 36C24618R0842-007.pdf | ||
| 36C24618R0842-006.pdf | ||
| 36C24618R0842-002.pdf | ||
| 36C24618R0842-000.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N4
V1
K1 E1
J1
Q1N2
C4
C1
B2
C3
D1
B1
B3
C6
K1
HYBRID 2
SCRUB
EXISTING EXTERIOR DOOR
TO BE LOCKED AND NO
ROOF ACCESS.
A430 8
A430 9
A430
A4307
EQ
TOILET
CORRIDOR
MECH
ELEC
ISOLATION POWER PANELS
2 - 12" D. X 30" W.
9'
A404
4 1/2"
2'
1/
2"
9 1/2"
SHAFT
1' - 10"
2'
1' - 10"
A103A
F0.0
G4.0L
F0.0
F0.0
F4.0F4.0
F4.0
F0.0
F0.0
F4.0
8' - 2 1/4"
6'
1/
8" 3'
7/ 8"
4' - 9 1/2"
7'
1/
2"
MOBILE
C-ARM
5083CLEAN
ELEVATOR
5077E
ELEVATOR
LOBBY
5077B
MECH
SEMI -
HYBRID 1
EQUIP. STOR
ANESTH.
OFFICE
ANESTH
WORK/
SUPPLY
SCRUB
TOILET
CLEAN CORE
A430
A43012
ISOLATION
POWER PANEL
12" D. X 30" W.
ISOLATION
POWER PANEL
12" D. X 30" W.
Case Cart Case Cart Case Cart
C-ARM, Moblie
SHAFT
SHAFT
A403
ISO-CENTER
G4.0L
G4.0L
G4.0L
G4.0L
W2
G4.0L
G4.0L
G4.0L
G4.0L
G4.0L
G4.0L
G4.0L
TOILET
MALE
LOCKERS
STERILE
SUPPLY
FEMALE
LOCKERS
TOILET
CLEAN CORE
A430 14
A430
A430 16A43017
LOCKERS,
BY OWNER
LOCKERS,
BY OWNER
A403
A403
Fluid Warmer
Warmer, Blanket
1'
8"
TA008TA008
A403
5 G4.1
G4.1
G4.1
F0.0
F4.0
F4.0
F4.0
F4.0
F0.0
F2.0
FEC FEC
NS WORK
A430
A430 18 A43018A430 21
SIM SIM
ISOLATION
ANTE
5010A
PATIENT
TOILET
A430 26
A430 27
A403
A403
F4.0
F4.0
F4.0
F0.0
F4.0
Cart, Resuscitation
Headwall Column
A430 28
5008C
5008B
5008A
2' - 0" 2' - 1 3/8"
G4.0
F4.0
F0.0
F4.0
G4.0
F0.0
F4.0
F2.0
F0.0
G4.0 G4.0
G4.1F2.0
F0.0
F4.0
F4.0
F0.0
Headwall Column
Headwall Column
Headwall Column
11' - 8"
2' - 0"
NS
A430
A4302324
CLEAN/ MEDS
Omnicell Ice Maker
1. ALL INTERIOR PARTITIONS TO BE TYPE G4.0 UNLESS NOTED OTHERWISE.
2. STUDS AND FURRING STRIPS AT 16" O.C.
3. DO NOT FASTEN TOP RUNNER TO STUDS. CRIMP RUNNER ON BOTH SIDES TO STABILIZE STUDS.
4. ALL INTERIOR PARTITIONS TO SEAL TO STRUCTURE ABOVE.
5. ALL INTERIOR PARTITIONS TO HAVE SOUND ATTENUATION INSULATION FOR FULL HEIGHT OF WALL.
NOT ALL PARTITIONS LISTED ABOVE ARE USED IN EACH VIEW.
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/2 /2
:5
:1
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th .c ru m p .r v t
A402
FIFTH FLOOR ENLARGED
PLANS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
AB, ES
RH
Salisbury, NC
100% FINAL DESIGN
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - HYBRID 2 SUITE
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - SEMI-HYBRID 1
SUITE
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - LOCKERS / STERILE
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - NURSE STATION
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - PACU ISOLATION
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - ISOLATION BAYS
1/4" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - NURSE STATION
WALL SCHEDULE
Type Face Structure Fire Rating UL # Comments
F0.0 5/8" Gyp. Bd., 1 layer 1 side 7/8" Metal Channels
F1.0 5/8" Gyp. Bd., 1 layer 1 side 1 5/8" Metal Channels
F2.0 5/8" Gyp. Bd., 1 layer 1 side 2 1/2" Metal Studs
F4.0 5/8" Gyp. Bd., 1 layer 1 side 4" Metal Studs
G4.0 5/8" Gyp. Bd., 1 layer ea. side 4" Metal Studs
G4.0L 5/8" Lead-Lined Gyp. Bd., 1 layer ea. side 4" Metal Studs
G4.1 5/8" Fire-Rated Gyp. Bd., 1 layer ea. side 4" Metal Studs 1-HR U419
G4.2 5/8" Fire-Rated Gyp. Bd., 2 layer ea. side 4" Metal Studs 2-HR U419
G6.0 5/8" Gyp. Bd., 1 layer ea. side 6" Metal Studs
M8.2 8" Concrete Masonry Unit 2-HR U905
S2.2 5/8" Fire-Rated Gyp. Bd., 2 layer 1 side, 1" liner panel, shaft side
2 1/2" C-H Studs 2-HR U415
S4.2 5/8" Fire-Rated Gyp. Bd., 2 layer 1 side, 1" liner panel, shaft side
4" C-H Studs 2-HR U415
S6.2 5/8" Fire-Rated Gyp. Bd., 2 layer 1 side, 1" liner panel, shaft side
6" C-H Studs 2-HR U415
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
1 05/08/17 Revision 1
2 10/31/17 Revision 2 - Hybrid 2
3'
0"
TA001
GRAB BAR
1'
TA003
TOILET PAPER
DISPENSER
3'
8"
TA004
SOAP DISPENSER
WALL MOUNTED
3'
4"
TA006
MIRROR
2'
8"
TA007
SANITARY NAPKIN
DISPOSAL
3'
8"
TA008 - WALL MOUNT
TA009 - NOT USED
PAPER TOWEL DISPENSER
4'
0"
TA011
TOWEL BAR
4'
0"
TA012
ROBE HOOK
5'
6"
TA015
MOP/BROOM
RACK
2'
DRINKING
FOUNTAIN
2'
SINK
WALL MOUNTED
1'
5"
TOILET
7'
0"
TA016
SHOWER CURTAIN
ROD
TA005
SHOWER BENCH
1'
6"
1'
TA002
TOILET PAPER
DISPENSER
SHOWER
HEAD
MAX
1' - 3"
FIRE
EXTINGUISHER
T O
T O
P O
F T
A N
K
3'
6"
CABINET PER
SPECS
5'
6"
TA014
TOWEL
RACK/SHELF
1'
5"
URINALMATERIAL TO CL OF FIXTURE
1' - 6" , FACE OF FINISH
LOCATION OF BAR
SHALL BE BASED
ON TOILET CL
BACK WALL SIDE WALL
NOTES:
1. REFERENCE ACCESSORY MOUNTING SCHEDULE FOR MOUNTING HEIGHTS ABOVE FINISH FLOOR .
2. DIMENSIONS SHALL BE TAKEN FROM FACE OF WALL FINISH MATERIAL. CONTRACTOR SHALL
COORDINATE LOCATIONS OF FIXTURES AND GRAB BARS WITH ANY TILE AND/OR PARTITIONS.
1'
6"
4' - 6"
3' - 4"
3' - 6" MIN
1' - 0" 2' - 0"
TOILET
3' - 0" 6"
3'
6" 1'
0"
1'
2"
TA001
TA007
TA003
TA001
TA012
A403
SIM
TOILET
TA001
TA003
TA012
TA001
6" 3' - 0"
3'
6" 1'
0"
1'
2"
A403
PATIENT
TOILET
1' - 3" 3' - 0"
1'
0"
6"
3'
6" 1'
2"
TA003
TA008
TA001
TA010
TA012
TA007
A403
1'
0" C
LE
A
R , M
IN
M
IN
1/
2" C
LE
A
R
SURFACE-MOUNTED
ACCESSORY ABOVE
GRAB BAR
GRAB BAR. MAINTAIN MINIMUM
1'-0" CLEAR ABOVE BAR AND
MIN 1 1/2" CLEAR BELOW BAR
AT ALL TIMES.
SURFACE-MOUNTED
ACCESSORY BELOW
GRAB BAR
P-4A
WSF-4A COVE BASE
WP-2 WALL PANEL
(WET WALL ONLY)
FIELD CUT END INSTALLED
BEHIND COVE BASE
FACTORY FINISHED
RADIUS EDGE
6'
8" 4"
TA010
TA004
P-4A
WSF-7 COVE BASE
WP-2 WALL PANEL
(WET WALL ONLY)
FIELD CUT END INSTALLED
BEHIND COVE BASE
FACTORY FINISHED
RADIUS EDGE
4" 6'
8"
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/9
/2
:4
:5
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th
.s u m n e r@ rp a d e s ig n .n e t.
rv t
A403
ENLARGED TOILET
PLANS AND
ACCESSORIES
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
AB, ES
RH
Salisbury, NC
100% FINAL DESIGN
1/2" = 1'-0"
GRAB BAR CLEARANCES AT TOILETS
1/2" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - TOILET 5093
1/2" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - TOILET 5089
1/2" = 1'-0"
ENLARGED PLAN FIFTH FLOOR - TOILET 5009
TOILET ACCESSORY SCHEDULE
Accessory No. Description Manufacturer Model Furnish/Install
TA001 Grab Bar Bobrick, See Specifications for Other Manufacturers
B-5806
TA003 Toilet Paper Dispenser Bobrick, or equal B-4288
TA004 Soap Dispenser, Wall Mount N/A N/A
TA007 Sanitary Napkin Disposal Bobrick, or equal B-254
TA008 Paper Towel Dispenser Bobrick, See Specifications for Other Manufacturers
B-262
TA010 Mirror, Framed, 24"x36" Bobrick, or equal B-290
TA012 Robe Hook Bobrick, or equal B-672
3/4" = 1'-0"
TOILET ACCESSORIES AT GRAB BARS
1/2" = 1'-0"
ELEVATION - Typical Toilet Room Wet Wall
1/2" = 1'-0"
ELEVATIONS - Typical Private Toilet
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
1 05/08/17 Revision 1
FIFTH FLOOR
44' - 0"
ROOF
56' - 6"
EDECEBEA
T O
B O
TT
O
M O
F C
E
IL
IN
G
9'
0"
HYBRID 2
ISO CENTER
TABLE
ISO CENTER
C-ARM
N O
E X
C E
P T
IO
N
S T
A K
E N
9'
1/
4" A
.F .F
LINE OF CEILING BEYOND
FOURTH FLOOR
33' - 0"
FIFTH FLOOR
44' - 0"
ECEB
C E
IL
IN
G
9'
0"
CLEAN CORE
OR #2
CORRIDOR
Omnicell - Anesthesia
Workstation G4 Case Cart
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/2 /2
:5
:1
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th .c ru m p .r v t
A404
ENLARGED SECTIONS -
HYBRID OR 2 AND 4TH
FLOOR OR
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
ES
RH
Salisbury, NC
100% FINAL DESIGN
1/2" = 1'-0"
SECTION - HYBRID 2
1/2" = 1'-0"
SECTION - 4TH FLOOR OR
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
1 05/08/17 Revision 1
2 10/31/17 Revision 2 - Hybrid 2
SD
SD
SDSD
SD
SD
SD
SD
SD
SD
CL
CL
PS
PS
PS
SD
SD
SD
SD
SD
PS
PS
PS
PS
SD
PS
SD
CL
CL
SD
M L
OS
OS
OS
SD
SD
SD
SD
SD
A404
ELECTRICAL
SHOWER
SCRUB
OR #1
OR #2
EQ. STORAGE
CYSTO
STORAGE
STERILE
SUPPLY
SOIL HOLD
CLEAN CORE
STAIRS
NEPTUNE
DOCK
C-ARM
ALCOVE
CORRIDOR
9' - 0" 9' - 0"8' - 0"
8' - 0"
8' - 6"
8' - 0"
8' - 0"
M A
X
9"
3' - 2" 3' - 2"
M A
X
9"
M A
X
9"
M A
X
9"
3' - 2" 3' - 2"
8' - 0"
8' - 0"
1 1
8' - 6"
CORRIDOR
SHAFT
8' - 0"
8' - 0"
E Q
E Q
8' - 0"8' - 0"8' - 0"8' - 0"3' - 7"
E Q
E Q 7' - 5"
E Q
E Q
2' - 10"
EQEQ
3'
0"
2' - 2
EQ
EQ
E Q
E Q
EQEQEQEQ
1' - 8"
EQ
EQ
EQEQ
E Q
E Q
3' - 7"6' - 4"3' - 7"
E Q
E Q
8' - 0" 4' - 5"
5'
3"
ALIGN ALIGN
8' - 0"3' - 8"
ALIGN
E Q
E Q
EQEQ
7' - 5" 2' - 0"
2'x4' Acoustical Tile
REFLECTED CEILING
PLAN LEGEND
Access Panel
Lay-in Light
EXP
Indirect Lay-in Light
2'x2' Acoustical Tile
Gypsum Board Ceiling
Specialty Acoustical Ceiling Tile
Recessed Downlight
Ceiling Mounted Light
Pendant Light
Wall Mounted Light
Exit Sign
Suspended Linear Light 1x4
Suspended Linear Light 2x4
Strip Light
Supply
Return
Exhaust Air Grill
Linear Supply
Elevation Marker
See Electrical.
Luminaire, Ceiling Mounted.
See Electrical.
Luminaire, Ceiling Mounted.
Slash Indicates connected to Critical Branch.
See Electrical.
Luminaire, Ceiling Mounted.
Half-Shaded indicates connected to Emergency or Life Safety Branch.
Sprinkler Head
Recessed Heat Lamp
Exposed to Structure
Track Lighting
Cubicle Curtain Track
Lift Track
Ceiling Mounted Equipment
8'-0"
Smoke Detector
Spot Elevation Tag
Motion Sensor
9'-0"
SD
CEILING PLAN NOTES
1 24" x 24" ACCESS PANEL
2 -
CEILING GENERAL
NOTES
1. CEILING HEIGHTS TO BE 9'-0" A.F.F., U.N.O.
2. CONTRACTOR TO COORDINATE WITH ARCHITECT ANY INSTANCE WHERE
CEILING TILES ARE LESS THAN 4" IN WIDTH.
3. ALL GYPSUM BOARD CEILINGS AND SOFFITS TO BE PRIMED AND PAINTED
PER FINISH SCHEDULE, U.N.O.
4. WHERE FIELD CONDITIONS CAUSE VARIATIONS IN THE REFLECTED CEILING
PLAN, ANY ADJUSTMENTS WITH SPRINKLER HEADS, EXIST SIGNS OR LIGHT
FIXTURES MUST BE COORDINATED WITH THE ARCHITECT.
5. SEE ENGINEERING DRAWINGS FOR DETAILED CEILING LEGEND AND
SPECIFICATIONS.
6. G.C. TO FRAME ELECTRICAL FIXTURES AND MECHANICAL DIFFUSERS. G.C.
TO COORDINATE WITH MECHANICAL & ELECTRICAL SUBCONTRACTORS.
7. SOFFITS HEIGHTS TO BE 8'-0" A.F.F., U.N.O.
8. CENTER DEVICES INCLUDING DOWNLIGHTS, SPRINKLER HEADS, AND HVAC
GRILLES SMALLER THAN 2 BY 2 FEET, IN CEILING TILES, U.N.O.
9. CENTER EXIT SIGNS OVER DOORS, U.N.O.
10. ALIGN FACE OF SOFFIT WITH FACE OF PARTITION, U.N.O.
1. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED
CEILING PLANS WITH THE ELECTRICAL LIGHTING PLANS, WITH THE MECHANICAL
SUPPLY, RETURN AND EXHAUST PLANS, AND WITH THE FIRE PROTECTION PLANS, AND
HE SHALL REPORT TO THE ARCHITECT ANY ERROR, INCONSISTENCY OR OMISSION
THAT HE MAY DISCOVER PRIOR TO PROCEEDING.
2. SPRINKLER HEAD LOCATIONS ARE NOT INDICATED ON THE REFLECTED CEILING
PLANS. THE CONTRACTOR SHALL INSTALL SUFFICIENT HEADS IN ALL SPACES TO
PROVIDE COMPLETE (100%) AUTOMATIC SPRINKLER COVERAGE AS DEFINED IN NFPA
STANDARD 13, AND IN THE PROJECT MANUAL, AND AS REQUIRED BY THE OWNER'S
INSURANCE UNDERWRITER. CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING
LOCATIONS OF SPRINKLER HEADS FOR APPROVAL.
3. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF APPROPRIATE SIZE AND
TYPE ARE INSTALLED IN GYPSUM BOARD CEILINGS OR SOFFITS, IN CEMENT PLASTER
CEILINGS OR SOFFITS, AND IN OTHER NON-ACCESSIBLE TYPE CEILINGS OR SOFFITS
WHERE ACCESS, SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING OR
ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE THE FIRE RATED
TYPE EQUAL TO THE RATING OF THE CEILING OR SOFFIT IN WHICH THEY OCCUR.
4. ONLY CEILING MOUNTED EXIT LIGHTS ARE SHOWN ON THE REFLECTED CEILING
PLANS. SEE THE ELECTRICAL DRAWINGS FOR LOCATIONS OF WALL MOUNTED EXIT
LIGHTS.
5. SEE THE ELECTRICAL DRAWINGS AND/OR THE COMMUNICATIONS DRAWINGS FOR
LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS, SPEAKERS, FIRE ALARM
DEVICES, ETC.
6. THE CONTRACTOR SHALL PROVIDE ACCESS PANELS IN GYPSUM BOARD CEILINGS
FOR INSPECTION OF RATED AND/OR RATED SMOKE WALLS. THESE ACCESS PANELS
SHALL BE LOCATED AT INTERVALS NOT TO EXCEED 30'-0" ON CENTER, MINIMUM OF
ONE PER SPACE, AND IN SUCH MULTIPLE LOCATIONS AS NECESSARY TO VIEW ALL
SURFACES OF THE RATED AND/OR RATED SMOKE WALLS.
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/9
/2
:4
:1
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th
.s u m n e r@ rp a d e s ig n .n e t.
rv t
A405
FOURTH FLOOR
ENLARGED REFLECTED
CEILING PLANS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
AB, ES
RH
Salisbury, NC
100% FINAL DESIGN
1/4" = 1'-0"
ENLARGED RCP FOURTH FLOOR - OR SUITE SE WING
PS
CL
SD
OS
SD
SD
SD
DD
DD
OS
CLSD
CL
SD
SD
CL
SD
SD
SD
PS
PS
PS
PS
CL
OS
OS
SD
SD
2'x4' Acoustical Tile
REFLECTED CEILING
PLAN LEGEND
Access Panel
Lay-in Light
EXP
Indirect Lay-in Light
2'x2' Acoustical Tile
Gypsum Board Ceiling
Specialty Acoustical Ceiling Tile
Recessed Downlight
Ceiling Mounted Light
Pendant Light
Wall Mounted Light
Exit Sign
Suspended Linear Light 1x4
Suspended Linear Light 2x4
Strip Light
Supply
Return
Exhaust Air Grill
Linear Supply
Elevation Marker
See Electrical.
Luminaire, Ceiling Mounted.
See Electrical.
Luminaire, Ceiling Mounted.
Slash Indicates connected to Critical Branch.
See Electrical.
Luminaire, Ceiling Mounted.
Half-Shaded indicates connected to Emergency or Life Safety Branch.
Sprinkler Head
Recessed Heat Lamp
Exposed to Structure
Track Lighting
Cubicle Curtain Track
Lift Track
Ceiling Mounted Equipment
8'-0"
Smoke Detector
Spot Elevation Tag
Motion Sensor
9'-0"
SD
MECH
HYBRID 2
SCRUB
EQ
9' - 4 1/4"
9' - 0"
A.F.F. NO
EXCEPTIONS TAKEN
A406 3
A406
9' - 4"
"1
8' - 0"
SHAFT
4'
4'
6"
FINAL LAYOUT OF LIGHTS AND MECH DIFFUSERS TO
BE COORDINATED WITH CEILING MOUNTED EQ.
EQ
EQ
M A
X
9"
MIN
1' - 2"
MAX.
9"
6' - 0"2' - 9"
E Q
E Q
6'-0" +/-4' - 3"
6'
6" 4'
-6
3' - 6"
E Q
5'
3" 5'
3"
E Q
EQEQ
E Q
E Q
4' - 9" 4' - 8" 6' - 0" 6' - 0"
4' - 8" 4' - 10"
4'
5'
5"
0"
5'
5" 5'
5"
5'
5" 5'
5"
5'
5"
3'
0"
11' - 9" CLEAR
3' - 2 1/4"
1'
2'
0"
9' - 0"
8' - 6"
9' - 0"
8' - 6"
8' - 0"
8' - 0"
9' - 0"
9' - 0"
MECH
CLEAN
ELEVATOR
5077E
ELEVATOR
LOBBY
5077B
SEMI -
HYBRID 1
SCRUB
ANESTH.
OFFICE
ANESTH
WORK/
SUPPLY
EQUIP. STOR
CLEAN CORE
TOILET
MOBILE
C-ARM
3' - 2" 3' - 2"
MAX
9"
MAX
9"
1'
8"
FINAL LAYOUT OF LIGHTS AND MECH DIFFUSERS TO
BE COORDINATED WITH CEILING MOUNTED EQ.
3'
0" 3'
0"
EQ
EQ
3' - 0" 10' - 0" 10' - 0"
EQ
EQ
6'
0"
4'
0"
6'
0"
EQEQ
3' - 0"3' - 0"
8'
0"
4'
0"
3'
6" 5'
5"
0"
ALIGN
9' - 10"6' - 0"
ALIGN
5'
7"
ALIGN
ALIGN
3'
6"
4' - 6"
6'
1"
2'
8"
EQ
EQ
CEILING GENERAL
NOTES
1. CEILING HEIGHTS TO BE 9'-0" A.F.F., U.N.O.
2. CONTRACTOR TO COORDINATE WITH ARCHITECT ANY INSTANCE WHERE
CEILING TILES ARE LESS THAN 4" IN WIDTH.
3. ALL GYPSUM BOARD CEILINGS AND SOFFITS TO BE PRIMED AND PAINTED
PER FINISH SCHEDULE, U.N.O.
4. WHERE FIELD CONDITIONS CAUSE VARIATIONS IN THE REFLECTED CEILING
PLAN, ANY ADJUSTMENTS WITH SPRINKLER HEADS, EXIST SIGNS OR LIGHT
FIXTURES MUST BE COORDINATED WITH THE ARCHITECT.
5. SEE ENGINEERING DRAWINGS FOR DETAILED CEILING LEGEND AND
SPECIFICATIONS.
6. G.C. TO FRAME ELECTRICAL FIXTURES AND MECHANICAL DIFFUSERS. G.C.
TO COORDINATE WITH MECHANICAL & ELECTRICAL SUBCONTRACTORS.
7. SOFFITS HEIGHTS TO BE 8'-0" A.F.F., U.N.O.
8. CENTER DEVICES INCLUDING DOWNLIGHTS, SPRINKLER HEADS, AND HVAC
GRILLES SMALLER THAN 2 BY 2 FEET, IN CEILING TILES, U.N.O.
9. CENTER EXIT SIGNS OVER DOORS, U.N.O.
10. ALIGN FACE OF SOFFIT WITH FACE OF PARTITION, U.N.O.
1. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED
CEILING PLANS WITH THE ELECTRICAL LIGHTING PLANS, WITH THE MECHANICAL
SUPPLY, RETURN AND EXHAUST PLANS, AND WITH THE FIRE PROTECTION PLANS, AND
HE SHALL REPORT TO THE ARCHITECT ANY ERROR, INCONSISTENCY OR OMISSION
THAT HE MAY DISCOVER PRIOR TO PROCEEDING.
2. SPRINKLER HEAD LOCATIONS ARE NOT INDICATED ON THE REFLECTED CEILING
PLANS. THE CONTRACTOR SHALL INSTALL SUFFICIENT HEADS IN ALL SPACES TO
PROVIDE COMPLETE (100%) AUTOMATIC SPRINKLER COVERAGE AS DEFINED IN NFPA
STANDARD 13, AND IN THE PROJECT MANUAL, AND AS REQUIRED BY THE OWNER'S
INSURANCE UNDERWRITER. CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING
LOCATIONS OF SPRINKLER HEADS FOR APPROVAL.
3. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF APPROPRIATE SIZE AND
TYPE ARE INSTALLED IN GYPSUM BOARD CEILINGS OR SOFFITS, IN CEMENT PLASTER
CEILINGS OR SOFFITS, AND IN OTHER NON-ACCESSIBLE TYPE CEILINGS OR SOFFITS
WHERE ACCESS, SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING OR
ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE THE FIRE RATED
TYPE EQUAL TO THE RATING OF THE CEILING OR SOFFIT IN WHICH THEY OCCUR.
4. ONLY CEILING MOUNTED EXIT LIGHTS ARE SHOWN ON THE REFLECTED CEILING
PLANS. SEE THE ELECTRICAL DRAWINGS FOR LOCATIONS OF WALL MOUNTED EXIT
LIGHTS.
5. SEE THE ELECTRICAL DRAWINGS AND/OR THE COMMUNICATIONS DRAWINGS FOR
LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS, SPEAKERS, FIRE ALARM
DEVICES, ETC.
6. THE CONTRACTOR SHALL PROVIDE ACCESS PANELS IN GYPSUM BOARD CEILINGS
FOR INSPECTION OF RATED AND/OR RATED SMOKE WALLS. THESE ACCESS PANELS
SHALL BE LOCATED AT INTERVALS NOT TO EXCEED 30'-0" ON CENTER, MINIMUM OF
ONE PER SPACE, AND IN SUCH MULTIPLE LOCATIONS AS NECESSARY TO VIEW ALL
SURFACES OF THE RATED AND/OR RATED SMOKE WALLS.
CEILING PLAN NOTES
1 24" x 24" ACCESS PANEL
2 -
6"
4" METAL STUDS @ 16" O.C.
BRACED TO STRUCTURE ABOVE
5/8" GYP BD
CONTINUOUS CORNER BEAD
9' - 0"
9' - 4 1/4"
A.F.F.
NO EXCEPTIONS
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/2 /2
:5
:2
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th .c ru m p .r v t
A406
FIFTH FLOOR ENLARGED
REFLECTED CEILING
PLANS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
AB, ES
RH
Salisbury, NC
100% FINAL DESIGN
1/4" = 1'-0"
ENLARGED RCP FIFTH FLOOR - HYBRID 2 SUITE
1/4" = 1'-0"
ENLARGED RCP FIFTH FLOOR - SEMI-HYBRID 1 SUITE
1 1/2" = 1'-0"
CEILING - HYBRID OR SOFFIT DETAIL
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
1 05/08/17 Revision 1
Case Cart Case Cart Case Cart Case Cart
WP-1 WP-1
CG-1 CG-1
WP-1 WP-1
CG-1 CG-1CG-1
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
NURSE STATION MILLWORK N.I.C.
SHOWN FOR COORDINATION
PURPOSES ONLY
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
9'
0"
EDGE OF WALL
3'
0"
EDGE OF WALL
SHELVING N.I.C.
SHOWN FOR COORDINATION
PURPOSES ONLY
SHELVING N.I.C.
SHOWN FOR COORDINATION
PURPOSES ONLY
SHELVING N.I.C.
SHOWN FOR COORDINATION
PURPOSES ONLY
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
2'
6" 2'
6"
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
NURSE STATION
CASEWORK,
N.I.C.
2'
6" 2'
2"
2'
6"
7'
2" NURSE STATION
CASEWORK N.I.C.
NURSE STATION
MILLWORK N.I.C.
SHOWN FOR
COORDINATION
PURPOSES ONLY
TA008
TA004
Headwall Column
COVE BASE
BG-1
Headwall Column
COVE BASE
BG-1
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/2 /2
:5
:3
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th .c ru m p .r v t
A430
INTERIOR ELEVATIONS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
AB
RH
Salisbury, NC
100% FINAL DESIGN
1/4" = 1'-0"
ELEVATION - Clean Core 4009
1/4" = 1'-0"
ELEVATION - Scrub 4007
1/4" = 1'-0"
ELEVATION - Nurse Station 4020 A
1/4" = 1'-0"
ELEVATION - Nurse Station 4020 B
1/4" = 1'-0"
ELEVATION - Nurse Station 4020 C
1/4" = 1'-0"
ELEVATION - Nurse Station 4020 D
1/4" = 1'-0"
ELEVATION - Hybrid 2 5001 A
1/4" = 1'-0"
ELEVATION - Hybrid 2 5001 B
1/4" = 1'-0"
ELEVATION - Scrub 5094
1/4" = 1'-0"
ELEVATION - Clean Core 5087 A
1/4" = 1'-0"
ELEVATION - Clean Core 5087 B
1/4" = 1'-0"
ELEVATION - Scrub 5086
1/4" = 1'-0"
ELEVATION - Sterile Supply 5091 A
1/4" = 1'-0"
ELEVATION - Sterile Supply 5091 B
1/4" = 1'-0"
ELEVATION - Sterile Supply 5091 C
1/4" = 1'-0"
ELEVATION - F Lockers 5092
1/4" = 1'-0"
ELEVATION - M Lockers 5090
1/4" = 1'-0"
ELEVATION - NS Work 5077 A
1/4" = 1'-0"
ELEVATION - NS Work 5077 C
1/4" = 1'-0"
ELEVATION - NS Work 5077 D
1/4" = 1'-0"
ELEVATION - NS 5107 A
1/4" = 1'-0"
ELEVATION - NS 5107 B
1/4" = 1'-0"
ELEVATION - NS 5107 C
1/4" = 1'-0"
ELEVATION - Ante 5010A
1/4" = 1'-0"
ELEVATION - Isolation 5010
1/4" = 1'-0"
ELEVATION - Isolation Bay
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
TYP. RUNG CONNECTION TO STRINGER
ALUM. EXTRUDED SERRATED TREAD
ALUM. EXTRUDED
LADDER STRINGER
1/
4"
4 1/8"
6"
75.00°
S.S. H.H.M.B.
WITH NUT AND LOCK WASHER,
2 PER BRACKET
ALUM. FLAT BAR PIPE FLANGE
WELD ALL AROUND
ALUM. PIPE HANDRAIL & POST
ALUM. EXTRUDED
LADDER STRINGER
ALUM. SERRATED TREAD
ALUM. CHANNEL STRINGER
LA
D
D E
R W
ID
T
H 2'
0"
PLATFORM DIM.
2' - 0"
SIDE ELEVATIONFRONT ELEVATION
4" X 1 3/8" X 3/16" 2" LG. AL.
ANGLE STANDARD FLOOR
BRACKET (TYP.)
ALUM. SERRATED
TREAD
ALUM. EXTRUDED
CHANNEL LADDER
STRINGERS
PIPE HANDRAIL
3'
0"
2'
6"
2'
6"
3"
V A
R
IE
S
75.00°
LA
D
D E
R H
E
IG
H T
- V .I.
F.
3'
6"
E Q
U A
L S
P A
C E
S A
T
V
A R
IE
S
6" E
Q E
Q E
Q E
Q
SAFETY END CAP
SAFETY END CAP
ALUM. EXTRUDED CHANNEL
LADDER STRINGERS
LADDER WIDTH
2' - 0"
PIPE HANDRAIL
STANDARD BRACKET ANCHOR
BY OTHERS
A501
A501
A501
ED
E4
CFMF CHANNEL
CFMF
GYP
EB
E4
1' - 6 3/4" 10 1/2"
3'
1/
2"
EC
E1
ALIGN NEW PARTION TO
EXISTING WALL.
EC
E3
1' - 10"
1/
2"
1/ 2"
10"6 1/4"
1' - 4 1/4"5 3/4"
NEW FLEXIBLE FIRESTOP
SEALANT - MUST MEET
REQUIREMENTS FOR 2 HOUR
RATED FLOOR
NEW FLOORING MATERIAL AS
DIRECTED ON INTERIOR FINISH
DRAWINGS
LEVELING COMPOUND AS
REQUIRED FOR PROPER
FLOORING INSTALLTION -
BOTH SIDES OF JOINT
NEW 6" W. X 1/8" H. ALUM. COVER
PLATE. PLATE SHALL BE CON'T
FROM WALL TO WALL AND
EDGES TO BE BEVELED.
COORD. ANCHOR TYPE AND
SPACING WITH VENDOR
ROOF SYSTEM VARIES
ROOF MEMBRANE
SEALANT
WOOD NAILERS
ROOF DECK
1" MOLDED FIBER CANT
COPING/COUNTERFLASHING
LAP ROOF MEMBRANE OVER PARAPET
BLOCKING AND FASTEN
WOOD BLOCKING
CURB BEARING
CONFIGURATION VARIES
FLASHING MEMBRANE
BASE OF UNIT 1/2'' MIN.BEYOND
TOP OF CURB
MECHANICAL UNIT, HATCH, ETC.
COUNTERFLASHING
WOOD NAILER
1'' MIN. BELOW TOP OF CURB
FASTENERS
INSULATION
COMPRESSIBLE
ELASTOMERIC SEALANT
PREFABRICATED CURB
WOOD NAILER
THERMOSET ROOF
MEMBRANE
ROOF DECK
ROOF SYSTEM VARIES
FASTENERS
FLASHING MEMBRANE 8"
MIN. HEIGHT
REMOVABLE SHEET METAL
COUNTERFLASHING
GASKETED FASTENERS
MIN. TWO FASTENERS PER
SIDE
COMPRESSIBLE ELASTOMERIC
SEALANT - CONTINUOUS
PREFABRICATED CURB
SHEET METAL ENCLOSURE
WITH REMOVABLE TOP -
CROSSBREAK OR SLOPE
FOR DRAINAGE
INSULATE VOID
TO PREVENT
CONDENSATION
SHEET METAL OR
FLEX-TUBE COLLAR
SLOPE PIPES DOWN AND
AWAY FROM HOOD
REMOVABLE SHEET METAL
COUNTERFLASHING
ROOF DECK
THERMOSET ROOF MEMBRANE
ROOF SYSTEM VARIES
GASKETED FASTENERS
MINIMUM
TWO FASTENERS PER SIDE
SHEET METAL
FLASHING RECEIVER
WOOD NAILERS AND CURB
MIN. 4'' CLEARANCE
FROM PIPE TO TOP OF CURB -
MIN. 2'' BETWEEN PIPES
PITCH POCKETS ARE NOT ACCEPTABLE.
REINFORCED MEMBRANE
ATTACHMENT STRIP WITH
SEAM PLATES AND
FASTENERS
FLASHING MEMBRANE 8"
MIN. HEIGHT
ENCLOSURE FOR MULTIPLE PIPING/CONDUIT
PIPES/CONDUITS SHALL HAVE A
MINIMUM OF 12 INCHES OF
CLEARANCE ON ALL SIDES FROM
WALLS, CURBS, AND OTHER
PROJECTIONS FOR PROPER
FOR MULTIPLE PIPE/CONDUIT
PENETRATIONS WHERE 12"
CLEARANCE IS UNAVAILABLE, SEE ROOF DECK
ROOF SYSTEM VARIES
ROOF
MEMBRANE
BASE MEMBRANE
ATTACHMENT
PREFABRICATED
MEMBRANE FLASHING 8''
MIN. HEIGHT
SEALANT BETWEEN
PIPE/CONDUIT AND
PREFABRICATED MEMBRANE
FLASHING
PIPE/CONDUIT
DRAWBAND
SEALANT
FLASHING FOR INDIVIDUAL PIPING/CONDUIT
WOOD NAILERS AND CURB
ROOF DECK
ROOF SYSTEM VARIES
METAL OR GYPSUM LINER
REINFORCED MEMBRANE
ATTACHMENT STRIP WITH
SEAM PLATES AND
FASTENERS
THERMOSET ROOF MEMBRANE
INSULATE VOID FOR COLD
STACKS
REMOVABLE SHEET METAL
COUNTERFLASHING
07620
FLASHING MEMBRANE 8''
MIN. HEIGHT
GASKETED FASTENERS
MINIMUM TWO FASTENERS
PER SIDE
TEMPERATURE
APPROPRIATE ELASTOMERIC
SEALANT
DRAWBAND OR WELD
UMBRELLA TO STACK
ISOLATED STACK FLASHING (HOT OR COLD)
VAR
IES
BASE MEMBRANE ATTACHMENT
FILL GAPS WITH INSULATION
BOARD TO PROVIDE EVEN
SUBSTRATE
ROOF SYSTEM VARIES
ROOF MEMBRANE
ROOF DECK
FLASHING MEMBRANE 8'' MIN. HEIGHT
SEALANT
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/9
/2
:4
:4
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th
.s u m n e r@ rp a d e s ig n .n e t.
rv t
A501
EXTERIOR AND INTERIOR
DETAILS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
ES
RH
Salisbury, NC
100% FINAL DESIGN
6" = 1'-0"
SHIPS LADDER - TREAD DETAIL
6" = 1'-0"
SHIPS LADDER - POST DETAIL
1" = 1'-0"
SHIPS LADDER - PLATFORM PLAN
1/2" = 1'-0"
SHIPS LADDER - ELEVATIONS
1 1/2" = 1'-0"
PLAN DETAIL - TYPICAL WRAP AT EXISTING
EXTERIOR COLUMNS
1 1/2" = 1'-0"
PLAN DETAIL - 4TH FLOOR E4/EB
1 1/2" = 1'-0"
PLAN DETAIL - 4TH FLOOR E1/EC
1 1/2" = 1'-0"
PLAN DETAIL - 4TH FLOOR E3/EC
3" = 1'-0"
EXPANSION JOINT - REPLACEMENT
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
1 05/08/17 Revision 1
6" = 1'-0"
ROOF - Base Flashing
6" = 1'-0"
ROOF - Curb Flashing TPO
6" = 1'-0"
ROOF - Penetration Detail
6" = 1'-0"
ROOF - Pipe Flashing TPO
6" = 1'-0"
ROOF - Stack Flashing
6" = 1'-0"
ROOF - Steel Tube Flashing TPO
1/2"
2"
VARIES
STEEL FRAME
SEALANT EACH SIDE
BOX HEADER
9/16"
2"
VARIES
DOUBLE STUD
SEALANT EACH SIDE
STEEL FRAME
JAMB ANCHOR
1/2"
2"
VARIES
STEEL FRAME
SEALANT EACH SIDE
BOX HEADER
DOOR
CENTER-HUNG DOUBLE-
ACTING PIVOT
SMOKE SEAL
1/2"
2"
VARIES
DOUBLE STUD
SEALANT EACH SIDE
STEEL FRAME
JAMB ANCHOR
DOOR
SMOKE SEAL, BOTH SIDES
1/2"
2"
VARIES
SEALANT EACH
SIDE
BOX HEADER
5/8" GWB WITH 1/2" LEAD LINED GWB
EXTEND LEAD INTO FRAME
HOLLOW METAL FRAME
W/ LEAD SHIELDING
PROFILE P-X
ANGLES FASTENED
BOTH ENDS
GROUT FRAME
1/2"
2"
VARIES
DOUBLE STUD
SEALANT EACH SIDE
HOLLOW METAL
FRAME
W/ LEAD SHIELDING
PROFILE P-X
JAMB ANCHOR
5/8" GWB WITH 1/2" LEAD LINED GWB
EXTEND LEAD INTO FRAME
ANGLES FASTENED
BOTH ENDS
9/16"
2"
VARIES
GLASS
STEEL FRAME
SEALANT EACH SIDE
BOX HEADER
9/16"
2"
VARIES
DOUBLE STUD
SEALANT EACH SIDE
STEEL FRAME
JAMB ANCHOR
GLASS
9/16"
LEADED GLASS
SEALANT EACH SIDE
BOX HEADER
5/8" LEAD LINED GWB
EXTEND LEAD INTO FRAME
PROVIDE SHIM AND/OR
LEAD STRIP AS REQ'D
HOLLOW METAL FRAME
W/ LEAD SHIELDING
2" ON LEAD LINE SIDE
1 3/8" ON CONTROL ROOM SIDE
ATTACH PER MANUF. RECOMMENDATIONS
GROUT SOLID - PROFILE P-X
1/2"X1/2" REMOVABLE
GLAZING STRIPS
2"
VARIES
9/16"
DOUBLE STUD
SEALANT EACH
SIDE
HOLLOW METAL FRAME
W/ LEAD SHIELDING
2" ON LEAD LINE SIDE
1 3/8" ON CONTROL ROOM SIDE
ATTACH PER MANUF. RECOMMENDATIONS
GROUT SOLID - PROFILE P-X
JAMB ANCHOR
LEADED GLASS
5/8" LEAD LINED GWB
EXTEND LEAD INTO FRAME
PROVIDE SHIM AND/OR
LEAD STRIP AS REQ'D
1/2"X1/2" REMOVABLE
GLAZING STRIPS
2"
VARIES
W3
NOT USED
W2
LEAD SHIELDED HM FRAME
W4
LEAD SHIELDED HM FRAMEHM FRAME
W1 W5
LEAD SHIELDED HM FRAME
3'
0" 4'
0"
4'
6" 2'
6"
2' - 0" 3' - 0"
4'
6" 2'
6"
4' - 0"
3'
0" 5'
4"
4 EQ.
15' - 8"
GL-3GL-3GL-3GL-3
GL-3GL-3
GL-1
HAS BOTH CLOSER AND LATCH
12" MIN WHERE DOOR
18" MIN
WHERE DOOR LOCATIONS ARE NOT
DIMENSIONED ON PLAN, THESE MINIMUM
DIMENSIONS SHALL BE USED TO LOCATE
DOOR FROM ADJACENT PARTITIONS.
NOTIFY ARCHITECT PRIOR TO
PROCEEDING IF THESE DIMENSIONS CAN
NOT BE MET.
RE
Q
UI
RE
D
AD
A
CL
EA
RA
NC
ES
AD
DI
TI
O
NA
L
DI
M
EN
SI
O
NS
LOCATE DOOR BY HINGE JAMB DIMENSION
WHEN THIS DIM IS GREATER THAN 18",
6" AT HINGE JAMB
A
WIDTH HEIGHT HEIGHTWIDTH
B
C
D
E
F
G
H
I
J
K
L
M
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
7'-8"
1'-6"
2'-0"
2'-2"
2'-4"
2'-6"
2'-8"
2'-10"
3'-0"
3'-2"
3'-4"
3'-8"
3'-10"
1'-6"
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
7'-0"
8'-0"
2'-0"
2'-2"
2'-4"
2'-6"
2'-8"
3'-0"
3'-4"
3'-8"
3'-10"
UNASSIGNED
3'-6"
4'-0"
3'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
DOOR MODIFICATIONS
A LAMINATED GLASS
ADO AUTOMATIC DOOR OPERATOR (SWING OR SLIDE)
ALK AUDIBLE ALARM (ON EGRESS)
CL STAND-ALONE CARD READER LOCK
CR CARD READER
D DOUBLE GLAZED TEMPERED GLASS
DE DELAYED EGRESS
DPS DOOR POSITION SWITCH
F FIRE RATED GLAZING
H ELECTRIC HOLD OPEN
IC INTERCOM
ID INTEGRATED DOOR ASSEMBLY
IL INTERLOCKED
L LOUVER
LL LEAD-LINED DOORS
LP LIGHT PROOF LOUVER
M MECH. SEAL FOR LIGHT PROOF & SOUND
RETARDING DOOR
P PANIC HARDWARE
PB STAND-ALONE PUSHBUTTON LOCK
PP PUSH PAD
RF RADIOFREQUENCY SHIELDED DOOR
RR REMOTE RELEASE BUTTON
STC ACOUSTIC DOOR ASSEMBLY (INDICATE RATING #)
T TEMPERED GLASS
U UNDERCUT 1"
V LEAD GLASS
W WIRED GLASS
WP WAVE PLATE
NOTES:
1. ALL DOORS SHALL BE FLUSH - 1 3/4" THICK U.N.O.
2. TOP & SIDE RAILS SHALL BE 9" MIN. BOTTOM RAILS SHALL BE 12" MIN.
3. DOOR TYPES 7, 8, & 9 SHALL NOT BE USED FOR OPPOSING DOORS.
4. FOR SCHEDULING DOOR TYPES, SEE PG-18-14
5. EVEN NUMBERS ARE METAL; ODD NUMBERS ARE WOOD.
6. NUMBERS IN THE SCHEDULE FOR DOOR SYMBOL REFERS TO DOOR SIZE,
MATERIAL, AND MODIFICATION. DOOR FRAMES TO BE HOLLOW METAL, WITH
THE EXCEPTION OF ROOMS REQUIREM LEAD LINING.
DOUBLE
LETTERS
EQUAL
SIZE OF LEAF
FOR PAIR OF
DOORS
LEGEND (SEE ELEVATIONS)
GLASS OR LOUVER
REQUIRED BY MODIFICATION
GLASS OR LOUVER
REQUIRED BY ELEVATION
TYPE
DOOR SIZES
9"
100 IN² MAX
4"X25"
T.A. OR W/F
3'
6"
1'
0"
LOUVER SIZED
AS REQ'D
13 15/17
22 24
40 42
MUNTINS
AS REQ'D
T.A.
OR
W/F
'A' LABEL 'B' LABEL
3'
6"
9"
9"
9" 6"1' - 0" 9" 9"
100 IN² MAX
4"X25"
'F' GLASS
1296 IN² MAX.
EACH LEAF
4"X25"
'F' GLASS
DETENTION
TYPE
SOUND RATED
51 53
SHELF
'B' LABEL 'C' LABEL DUTCH DOOR
100 IN² MAX
4"X25"
LEAD GLASS
LEAD LINED
5'
0"
9"
9" 9"
9"
LOUVERS
AS REQ'D
1'
0"
SECURITY
RM DR
INTEGRATED
DOOR ASSEMBLY
INTEGRATED
DOOR ASSEMBLY
4'
2" 2'
0"
9"
9"
INTEGRATED
SLIDING DOOR
INTEGRATED
ICU DOOR
HOLLOW METAL
DOOR TYPES
(EVEN NUMBERS ARE HOLLOW METAL; ODD NUMBERS ARE WOOD)
FRAME TYPES
S
E E
S C
H E
D
2"
2" SEE SCHED. 2"
HOLLOW METAL
S E
E S
C H
E D
4"
2" SEE SCHED. 2"
9"
3'
6"
HOLLOW METAL
LEAD LINED
S E
E S
C H
E D
2"
2" SEE SCHED. 2"
GLAZING SCHEDULE:
TYPE
GL-1
DESCRIPTION
CLEAR GLASS
THICKNESS
1/4"
GL-2 CLEAR TEMPERED GLASS 1/4"
GL-3 CLEAR LEAD GLASS 1/4"
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/2 /2
:5
:3
A
M C
U s e rs \e liz a b e th
.s u m n e r\
D o c u m e n ts
\1 -0
-0
B
L D
G
O
R R e n o v
C e liz a b e th .c ru m p .r v t
A601
DOOR SCHEDULE &
WINDOW SCHEDULE
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/10/16
ES
RH/ FF
Salisbury, NC
100% FINAL DESIGN
DOOR SCHEDULE
Door Number Door Mark
(VA)
Door Number
(VA)
Door
Door Material
Door Modifications
(VA)
Frame
Material Frame
Elevation Fire Rating Door
Hardware Comments
Size
Width Height
THIRD FLOOR
3159 S 1 3' - 0" 7' - 0" WD HMTL 1 3E
3161 S 5 3' - 0" 7' - 0" WD HMTL 1 120 Min. Per Elev. Code
5G
3162 Q 1 2' - 6" 7' - 0" WD HMTL 1 5D
FOURTH FLOOR
4003 X 15 4' - 0" 7' - 0" WD HMTL 1 45 Min. 4K
4005 V 11 3' - 8" 7' - 0" WD T HMTL 1 45 Min. 5F
4006A SS 1 6' - 0" 7' - 0" WD T-WP-ADO HMTL 1 10H LITE IN 4' DOOR ONLY
4006B X 1 4' - 0" 7' - 0" WD T HMTL 1 1B
4008A SS 1 6' - 0" 7' - 0" WD T-WP-ADO HMTL 1 10H LITE IN 4' DOOR ONLY
4008B X 1 4' - 0" 7' - 0" WD T HMTL 1 1B
4009A X 1 4' - 0" 7' - 0" WD T HMTL 1 4C
4009B S 1 3' - 0" 7' - 0" WD T HMTL 1 4C
4010 X 11 4' - 0" 7' - 0" WD HMTL 1 45 Min. 5F
4011 S 11 3' - 0" 7' - 0" WD HMTL 1 45 Min. 5F
4013 S 1 3' - 0" 7' - 0" WD HMTL 1 5F
4016A X 1 4' - 0" 7' - 0" WD HMTL 1 4C
4016B S 1 3' - 0" 7' - 0" WD HMTL 1 4C
4018 S 1 3' - 0" 7' - 0" WD HMTL 1 5D
4019 S 1 3' - 0" 7' - 0" WD HMTL 1 5D
4130 N/A N/A 4' - 0" 7' - 0" N/A HMTL 1 OPENING
FIFTH FLOOR
5001 SS 15 6' - 0" 7' - 0" WD LL-V-WP-ADO HMTL 3 10H LEAD LINED
5001A S 15 3' - 0" 7' - 0" WD LL-V HMTL 3 1S LEAD LINED
5001B S 15 3' - 0" 7' - 0" WD LL-V HMTL 3 1S LEAD LINED
5002 S 15 3' - 0" 7' - 0" WD LL-V HMTL 3 5F LEAD LINED
5005 S 1 3' - 0" 7' - 0" WD HMTL 1 5D
5007 X 11 4' - 0" 7' - 0" WD HMTL 1 45 Min. 5F
5007A S 1 3' - 0" 7' - 0" WD HMTL 1 2
5007B S 1 3' - 0" 7' - 0" WD HMTL 1 5F
5009 S 1 3' - 0" 7' - 0" WD HMTL 1 2
5010 X 1 4' - 0" 7' - 0" WD HMTL 1 1R
5010A S 1 3' - 0" 7' - 0" WD HMTL 1 1R
5010B S 1 3' - 0" 7' - 0" WD HMTL 1 1R
5070 S 1 3' - 0" 7' - 0" WD HMTL 1 3E
5071 S 11 3' - 0" 7' - 0" WD HMTL 1 45 Min. 5F
5072 S 1 3' - 0" 7' - 0" WD HMTL 1 3E
5073 S 1 3' - 0" 7' - 0" WD HMTL 1 4K
5077B X 1 4' - 0" 7' - 0" WD HMTL 1 4C
5078A 7' - 0" 7' - 0" ALUM WP-ADO-T ALUMN BI-PARTING AUTO DOOR
5078B 7' - 0" 7' - 0" ALUM WP-ADO-T ALUMN BI-PARTING AUTO DOOR
5084A SS 15 6' - 0" 7' - 0" WD LL-V-WP-ADO HMTL 3 10H LEAD LINED
5084B V 15 3' - 8" 7' - 0" WD LL-V HMTL 3 1B LEAD LINED
5087 V 1 3' - 8" 7' - 0" WD T HMTL 1 1F
5089 S 1 3' - 0" 7' - 0" WD HMTL 1 2
5090A S 1 3' - 0" 7' - 0" WD HMTL 1 1
5090B S 1 3' - 0" 7' - 0" WD HMTL 1 1
5091A S 11 3' - 0" 7' - 0" WD T HMTL 1 45 Min. 4C
5091B S 11 3' - 0" 7' - 0" WD T HMTL 1 45 Min. 4C
5092A S 1 3' - 0" 7' - 0" WD HMTL 1 1
5092B S 1 3' - 0" 7' - 0" WD HMTL 1 1
5093 S 1 3' - 0" 7' - 0" WD HMTL 1 2
5106 S 1 3' - 0" 7' - 0" WD HMTL 1 SH-3D
3" = 1'-0"
DOOR INTERIOR - Interior Door Head Detail
3" = 1'-0"
DOOR INTERIOR - Interior Door Jamb Detail
3" = 1'-0"
DOOR INTERIOR - Double Acting - Door Head
3" = 1'-0"
DOOR INTERIOR - Double Acting - Door Jamb
3" = 1'-0"
DOOR INTERIOR - LEAD LINED DOOR HEAD DETAIL -
HMTL FRAME
3" = 1'-0"
DOOR INTERIOR - LEAD LINED DOOR JAMB DETAIL -
HTML FRAME
3" = 1'-0"
WINDOW INTERIOR - Interior Window Head Detail - HMTL Frame
3" = 1'-0"
WINDOW INTERIOR - Interior Window Jamb Detail - HMTL Frame
3" = 1'-0"
WINDOW INTERIOR - Interior Window Lead Lined Head Detail - HMTL Frame
3" = 1'-0"
WINDOW INTERIOR - Interior Window Lead Lined Jamb Detail - HMTL Frame
1/4" = 1'-0"
WINDOW TYPES
3/8" = 1'-0"
DOOR - Typical Door Location Dimensions
NTS
DOOR - SIZE & ABBR. LEGEND
1/4" = 1'-0"
DOORS AND FRAMES - TYPE LEGEND
ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription
1 05/08/17 Revision 1
2 10/31/17 Revision 2 - Hybrid 2
ABBREVIATIONS
VA Salisbury
ACT
ACT(SP)
AWP
AF
AWF
BL
BG
C
CC
CG
CP
CPT
CR
CRM
CS
CMP
CSM
CT
DC
DCP
DG
DFG
DP
EG
EXP
FW
FB
FT
GL
GR
GWB
GWB(SP)
HIT
H.MTL
HR
LAM
LPC
LN
LVT
MP
NIC
P
PF
PRB
PT
QT
RAF
RB
RES
RF
RP
RSF
RS
S
SAF
SCONC
SD
SP
SS
ST
SVT
TAC
TER
TT
TR
VCT
W
WD
WB
WG
WOM
WR
WSF
WT
ACOUSTICAL CEILING TILE
ACOUSTICAL CEILING TILE (W/SPRAY APPLIED PLASTIC FINISH)
ACOUSTICAL WALL PANELS
ACCESS FLOORING
AWNING FABRICS
BLINDS
BUMPER GUARD
CONCRETE
CUBICLE CURTAIN
CORNER GUARD
CARPET
CARPET TILE
CHAIR RAIL
CROWN MOLDING
CASING
CAST MARBLE PANEL
CAST STONE MASONARY
CERAMIC TILE (FLOOR, BASE, AND WALL)
DECORATIVE CANOPY
DECORATIVE CEILING PANELS
DECORATIVE GRILL
DOOR FRAME GUARD
DOOR PROTECTION
END GUARD
EXPOSED STRUCTURE
FABRIC WALLCOVERING
FIBER BOARD
FILM TINT
GLASS (GLAZING)
GROUT
GYPSUM WALLBOARD SYSTEMS
GYPSUM WALLBOARD SYSTEMS(W/SPRAY APPLIED PLASTIC FINISH)
HIGH IMPACT THERMOPLASTIC
HOLLOW METAL
HANDRAIL
LAMINATE
LAMINATE PLANK CEILING
LINOLEUM
LUXURY VINYL TILE
MANUFACTURED PANEL
NOT IN CONTRACT
(OWNER FURNISHED)
PAINT
PANEL FABRIC
PROFILE BASE
PORCELAIN TILE (FLOOR, BASE AND WALL)
QUARRY TILE
RESILIENT ATHLETIC FLOORING
RESILIENT BASE
(RUBBER OR VINYL WITH FACTORY FORMED INSIDE AND
OUTSIDE CORNERS)
RESINOUS FLOORING
RUBBER FLOOR
RESIN PANEL
RESILIENT SHEET FLOORING (CHEMICALLY WELDED SEAMS)
ROLLER SHADES
SOLID SURFACE MATERIAL
SEAMLESS SOUND ABSORPTIVE ACOUSTICAL SYSTEM
STAINED CONCRETE
STATIC DISSIPATIVE
SPECIAL FACED
STAINLESS STEEL
STAIN
SOLID VINYL FLOOR TILE
TEXTURED ACRYLIC COATING
TERRAZZO, POURED
TERRAZZO TILE (PLASTIC MATRIX)
TREAD (STAIR)
RESILIENT TILE FLOORING (VINYL COMPOSITION TILE)
WALLCOVERING
WOOD
WOOD BASE
WALL GUARD
WALK-OFF MAT
WELDING ROD
WELED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
WINDOW TRIM
SEALANT @ TOP OF CAP
PREFABRICATED COVE
FORM
SHEET FLOORING AS
SCHEDULED
6" U
N O
ALL SEAMS, COVES, AND
CORNERS SHALL BE SMOOTH
TO ALLOW EASE OF CLEANING
COVE BASE TO OVERLAP
WALL PANEL
BOTTOM OF CORNER GUARDS
BEGIN AT TOP OF BASE
BASE
FINISH FLOOR
CORNER GUARD INSTALLED
PER MFR. INSTRUCTIONS.
3' -0
A
F F
IF001CONTINUOUS ALUMINUM
RETAINER
VINYL COVER
SELF -TAPPING SCREWS
2"
2"
3"
1"
CONTINUOUS
ALUMINUM RETAINER
VINYL COVER
#10 X 1 3/4" METAL SCREW
WITH ALLIGATOR ANCHOR
1'-2" AFF
INTERIOR FINISH
GENERAL NOTES
1. ALL GROMMETS TO BE 2" DIAMETER, COLOR TBD AND TO BE APPROVED BY
ARCHITECT.
2. WALL TO BE PAINTED P-1 U.N.O., ALL PAINT TO BE EGGSHELL FINISH,
UNLESS OTHERWISE NOTED.
3. TRANSITIONS BETWEEN DISSIMILAR FLOOR FINISHES TO OCCUR AT
CENTERLINE OF DOOR UNLESS NOTED OTHERWISE. INSTALL TRANSISTION
STRIPS PER DETAILS. ARCHITECT TO APPROVE COLOR OF TRANSITION STRIP.
4. ALL DOOR FRAMES TO BE PAINTED P-7 UNLESS NOTED OTHERWISE. FINISH
TO BE SEMI-GLOSS.
5. ALL FIRE EXTINGUISHER CABINETS, ELECTRICAL PANELS, SUPPLIES AND
METAL GRILLS TO BE FACTORY PAINTED ENAMEL PAINT. PAINT IS TO MATCH
ADJOINING WALL.
6. ALL DOORS TO BE STAINED TO MATCH EXISTING. STAIN SAMPLES TO BE
APPROVED BY ARCHITECT.
7. ALL GROUT TO BE SEALED A MINIMUM OF 2 TIMES.
8. ALL GROUT JOINTS TO BE 1/4" MIN. U.N.O.
9. ALL CORRIDOR WALLS TO BE P-1 U.N.O.
10. ALL CONTINUOUS CAULK AT BACKSPLASH TO BE CLEAR.
11. ALL CORNER GUARDS TO BE CG-1 U.N.O.
12. ALL WALL GUARDS TO BE WG-1 U.N.O. WITH MATCHING TOP CAP.
13. ALL SOFFITS TO BE PAINTED P-7, ALL SIDES U.N.O.
14. ALL SUBFLOORS TO BE LEVELED PRIOR TO FLOORING INSTALLATION - TYP.
15. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR ALL NON-FINISH
DETAILS.
16. ALL ELEMENTS THAT APPEAR TO ALIGN, MUST ALIGN.
17. PORCELAIN FLOOR TILES IN BATHROOMS, 12" X 24" TO BE INSTALLED IN A
BRICK PATTERN. CERAMIC WALL TILES TO BE INSTALLED IN VERTICAL STACK /
SOLDIER PATTERN. INSTALL MOSAIC TILE IN A 4" HIGH ACCENT STRIP WITH
TILES RUNNING VERTICALLY AT APPROX. 48" HIGH.
18. REFERENCE FINISH TAGS FOR FINISH OF ALL GYP CEILINGS.
19. ALL FINISHES TO MEET THE REQUIREMENTS OF CLASS B OR BETTER
ACCORDING TO THE IBC 2012 SECTION 8, INCLUDING BUT NOT LIMITED TO
803.5.
20. INTERIOR FINISHES SHALL COMPY WITH 03 OF THE IFC 2009 EDITION.
21. SEE ELEVATION 06/IF001 FOR ELEVATOR CAB WALL FINISH AND DESIGN.
INTERIOR FINISH
SPECIFICATIONS:
Acoustical Ceiling:
AT-1 Armstrong Style: Ultima 1910 Edge: Square Lay-In Size: 24" x 24" x 3/4" Color: White Grid: Prelude15/16" Grid Color: White
Paint:
P-1 Manufacturer: ICI Dulux / Glidden Color: Flaxen White Number: #30 YY 71/138 Finish: Low Luster / Eggshell
P-1A Manufacturer: Wolf Gordon Scuffmaster Color: Scrubtough to match Flaxen White Number: Custom #30 YY 71/138 Finish: ST
P-2 Manufacturer: Sherwin Williams Color: Ponder Number: SW 7079 Finish: Low Luster / Eggshell
P-2A Manufacturer: Wolf Gordon Scuffmaster Color: Scrubtough to match Ponder Number: SW 7079 Finish: ST
P-3 NOT USED
P-4 Manufacturer: ICI Dulux / Glidden Color: Spa Blue Number: #70 BG 40/050 Finish: Low Luster / Eggshell
P-4A Manufacturer: Wolf Gordon Scuffmaster Color: Scrubtough to match Spa Blue Number: #70 BG 40/050 Finish: ST
P-5 NOT USED
P-6 Manufacturer: Sherwin Williams Color: Ceiling White
P-6A Manufacturer: Wolf Gordeon Scuffmaster Color: Scrubtough to match Ceiling White Finish: ST
P-7 Manufacturer: Sherwin Williams Color: Poised Taupe Number: SW 6039 Note: Semi-Gloss finish Door Frames only, Low-Luster / Eggshell when used on walls.
Rubber Base:
RB-1 Manufacturer: Johnsonite
Style: Traditional Cove with Integral Toe Color: Fawn 80 Size: 4" x 120' Coiled Length
Special Coatings:
SP-1 Manufacturer: Stonhard Series: Soneglase VSR Color: TBS
Stair Tread:
TR-1 Manufacturer: Johnsonite Series: Hammered Stair Tread w/out Riser (visually impaired):VIHMT Color: Fawn 80
ALL FINISHES ARE LISTED AS BASIS OF DESIGN. CONTRACTOR TO PROVIDE
PRODUCT OR EQUAL FOR APPROVAL BY OWNER, ARCHITECT AND INTERIOR
DESIGNER.
Corner Guard:
CG-1 Manufacturer: Inpro Corporation
Style: G2-150, PVC Free Size: 3" x 8" Color: Chamois 0234 Mount: Surface Mount
Bumper Guards:
BG-1 Inpro Style: 500 Color: Chamois 0234 Mounting: See 05/IF001
End Guard:
EG-1 Manufacturer: Inpro Corporation
Series: 160D End Wall Guard, #168 Size: 2" x 8' Color: Chamois 0234 Mount: Surface Mount
Handrail:
HR-1 Manufacturer: Inpro Corporation
Style: 900 Series Color: American Teak 0553 Mounting Bracket: 909 Stainless Steel
Rubber Floor:
RF-1 Manufacturer: Johnsonite
Style: Microtone Rubber Tile Color: LE2 Chocolate Cream Size: 24" x 24" Thickness: 1/8" (3.175 MM)
Solid Vinyl Tile:
SVT-1 Manufacturer: Azrock Style: Cortina Grande Color: CG510 Grille Grey Size: 16" x 16" tiles
Acoustical Ceiling (Spray Applied Special Coating):
AT(SP)-1 Armstrong Style: Ultima Health Zone 1935 Edge: Square Lay-In Special Coatings Size: 24" x 24" x 5/8" Color: White Grid: 15/16" Grid Color: White
AT(SP)-2 Armstrong Style: Ultima Health Zone 1935 Edge: Square Lay-In Special Coatings Size: 24" x 24" x 5/8" Color: White Grid: With Gaskets 15/16" Grid Color: White
Welding Seam Sheet Flooring (Heat Welded with Rod):
WSF-1 Manufacturer: Shannon Specialty Floors Style: Barenaked, CS Collection Color: CS5507 Latte Size: 4'9" Width Thickness: 2mm
WSF-2 Manufacturer: Shannon Specialty Floors Style: Barenaked, CS Collection Color: CS5511 French Macaroon Size: 4'9" Width Thickness: 2mm
WSF-3 Manufacturer: Shannon Specialty Floors Style: Barenaked, CS Collection Color: CS5561 Spring Water Size: 4'9" Width Thickness: 2mm
WSF-4 Manufacturer: Shannon Specialty Floors Style: Barenaked, CS Collection Color: CS5544 Rasberry Size: 4'9" Width Thickness: 2mm
WSF-5 Manufacturer: Tecknoflor Collection: Forestscapes Color: Medium Walnut 31097 Size: 6' Width x 75' Long Thickness: 2.3mm
WSF-6 Manufacturer: Tecknoflor Collection: Mountainscapes Color: Kashmere Creme 8661 Size: 6' Width x 75' Long Thickness: 2.3mm
WSF-7 Manufacturer: Tecknoflor Collection: Mountainscapes Color: River 88001 Size: 6' Width x 75' Long Thickness: 2.3mm
Resinous Flooring:
RES-1 Manufacturer: Stonhard
Style: Stonrez RTZ Color: TBD - Custom Color Base: Integral Cove Base
Plastic Laminate:
PLAM-1 Manufacturer: Wilsonart
Style / Pattern: Pewter Mesh Number: 4878-38
PLAM-2 Manufacturer: Wilsonart Style / Pattern: Sable Soapstone Number: 4883-38
Luxury Vinly Tile:
LVT-1 Manufacturer: Shaw
Style: Jeogori Color: Fiber Size: 18" x 18" Edge: Square Dye Lot 03MQ13C
Wall Protection:
WP-1 Manufacturer: Inpro Corporation Style: G2405, PVC Free Color: Chamois 0234 Size: 4' x 8', .40 Thick
Ceramin Tile:
CT-1 Manufacturer: Daltile
Style: Skybridge Color: Beige SY96 Size: 10" x 14" Wall Tile Installation: Vertical Stack / Soldier Patter Grout: Mapei, 14 Biscuit, epoxy, 1/8" grout joint
CT-2 Manufacturer: Daltile Style: Skybridge Color: Beige SY96 Size: 10" x 3" Bullnose S-4310 Grout: Mapei, 14 Biscuit, epoxy, 1/8" grout joint
Mosaic Tile:
MT-1 Manufacturer: Daltile
Style: Lucent Skies Mosaic Color: Sunlit Dawn LS09384MS1P Size: 12" x 12" Mesh backed sheet Installation: 4" accent stripe with tiles running vertically @ approx. 48" AFF Grout: Mapei, 14 Biscuit, epoxy, 1/8" grout joint
Porcelain Tile:
PT-1 Manufacturer: Daltile
Style: Dignitary Color: Notable beige - Unpolished DR09 Size: 12" x 24" Installation: Brick Pattern Grout: Mapei,39 Ivory, epoxy, 3/16" grout joint
PT-2 Manufacturer: Daltile Style: Dignitary Color: Notable beige - Unpolished DR09 Size: 6" x 12" S-36C9T Grout: Mapei,39 Ivory, epoxy, 3/16" grout joint
FINISH FLOOR
PLAM-1
PANEL
PLAM-2
PANEL
STAINLESS BUMPER GUARD
/ HANDRAIL
PLAM-2
PANEL
PLAM-2
PANEL
PLAM-1
PANEL
PLAM-1
PANEL
STAINLESS REVEALS
*NOTE: ELEVATION IS
REPRESENTATION OF DESIRED
ELEVATOR CAB. FINAL PANEL
DESIGN AND WALL FINISHES TO
BE SELECTED AND APPROVED
DURING SUBMITTAL PROCESS
FROM ELEVATOR
MANUFACTURER STANDARDS.
1/
2"
3/
8"
3"
1 1/2"
909SS MOUNTING BRACKET
1/4 - 20 X 3" HEX HEAD
SCREW W/ PHILLIPS
HEAD SLOT
CONT. 900M & 900MF
ALUM. HANDRAIL
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
RPA Design Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record
5960 Fairview Road
Suite 500
Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program ManagerProgram ManagerProgram ManagerProgram Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/1
/2
:5 :3
A
M C
U s e rs \a n n z ie
.b a rf ie ld .R
P A
D E
S
IG
N \D o c u m e n ts
\1
-0
-0
B
L D
G
O
R R e n o v C
A n n z ie b .r v t
IF001
INTERIOR FINISH
SCHEDULE AND DETAILS
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
11/1…