36C24618R0842-002.pdf

PDF 16 MB Posted

Attached to
Project 659-16-101, Correct Operating Room Deficiencies Federal contract opportunity
Solicitation number
36C24618R0842
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

36C24618R0842 CONTRACT ATTACHMENT A - DRAWINGS - FILE 1 - Architectural.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Project 659-16-101, Correct Operating Room Deficiencies, newest first.
File Type Posted
36C24618R0842-0002004.pdf PDF
36C24618R0842-0002002.pdf PDF
36C24618R0842-0002000.docx DOCX document
36C24618R0842-0002003.pdf PDF
36C24618R0842-0002001.pdf PDF
36C24618R0842-007.pdf PDF
36C24618R0842-006.pdf PDF
36C24618R0842-005.pdf PDF
36C24618R0842-008.docx DOCX document
36C24618R0842-003.pdf PDF
36C24618R0842-001.docx DOCX document
36C24618R0842-009.pdf PDF
36C24618R0842-004.pdf PDF
36C24618R0842-000.docx DOCX document
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N4

V1

K1 E1

J1

Q1N2

C4

C1

B2

C3

D1

B1

B3

C6

K1

HYBRID 2

SCRUB

EXISTING EXTERIOR DOOR

TO BE LOCKED AND NO

ROOF ACCESS.

A430 8

A430 9

A430

A4307

EQ

TOILET

CORRIDOR

MECH

ELEC

ISOLATION POWER PANELS

2 - 12" D. X 30" W.

9'

A404

4 1/2"

2'

1/

2"

9 1/2"

SHAFT

1' - 10"

2'

1' - 10"

A103A

F0.0

G4.0L

F0.0

F0.0

F4.0F4.0

F4.0

F0.0

F0.0

F4.0

8' - 2 1/4"

6'

1/

8" 3'

7/ 8"

4' - 9 1/2"

7'

1/

2"

MOBILE

C-ARM

5083CLEAN

ELEVATOR

5077E

ELEVATOR

LOBBY

5077B

MECH

SEMI -

HYBRID 1

EQUIP. STOR

ANESTH.

OFFICE

ANESTH

WORK/

SUPPLY

SCRUB

TOILET

CLEAN CORE

A430

A43012

ISOLATION

POWER PANEL

12" D. X 30" W.

ISOLATION

POWER PANEL

12" D. X 30" W.

Case Cart Case Cart Case Cart

C-ARM, Moblie

SHAFT

SHAFT

A403

ISO-CENTER

G4.0L

G4.0L

G4.0L

G4.0L

W2

G4.0L

G4.0L

G4.0L

G4.0L

G4.0L

G4.0L

G4.0L

TOILET

MALE

LOCKERS

STERILE

SUPPLY

FEMALE

LOCKERS

TOILET

CLEAN CORE

A430 14

A430

A430 16A43017

LOCKERS,

BY OWNER

LOCKERS,

BY OWNER

A403

A403

Fluid Warmer

Warmer, Blanket

1'

8"

TA008TA008

A403

5 G4.1

G4.1

G4.1

F0.0

F4.0

F4.0

F4.0

F4.0

F0.0

F2.0

FEC FEC

NS WORK

A430

A430 18 A43018A430 21

SIM SIM

ISOLATION

ANTE

5010A

PATIENT

TOILET

A430 26

A430 27

A403

A403

F4.0

F4.0

F4.0

F0.0

F4.0

Cart, Resuscitation

Headwall Column

A430 28

5008C

5008B

5008A

2' - 0" 2' - 1 3/8"

G4.0

F4.0

F0.0

F4.0

G4.0

F0.0

F4.0

F2.0

F0.0

G4.0 G4.0

G4.1F2.0

F0.0

F4.0

F4.0

F0.0

Headwall Column

Headwall Column

Headwall Column

11' - 8"

2' - 0"

NS

A430

A4302324

CLEAN/ MEDS

Omnicell Ice Maker

1. ALL INTERIOR PARTITIONS TO BE TYPE G4.0 UNLESS NOTED OTHERWISE.

2. STUDS AND FURRING STRIPS AT 16" O.C.

3. DO NOT FASTEN TOP RUNNER TO STUDS. CRIMP RUNNER ON BOTH SIDES TO STABILIZE STUDS.

4. ALL INTERIOR PARTITIONS TO SEAL TO STRUCTURE ABOVE.

5. ALL INTERIOR PARTITIONS TO HAVE SOUND ATTENUATION INSULATION FOR FULL HEIGHT OF WALL.

NOT ALL PARTITIONS LISTED ABOVE ARE USED IN EACH VIEW.

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/2 /2

:5

:1

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th .c ru m p .r v t

A402

FIFTH FLOOR ENLARGED

PLANS

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

AB, ES

RH

Salisbury, NC

100% FINAL DESIGN

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - HYBRID 2 SUITE

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - SEMI-HYBRID 1

SUITE

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - LOCKERS / STERILE

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - NURSE STATION

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - PACU ISOLATION

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - ISOLATION BAYS

1/4" = 1'-0"

ENLARGED PLAN FIFTH FLOOR - NURSE STATION

WALL SCHEDULE

Type Face Structure Fire Rating UL # Comments

F0.0 5/8" Gyp. Bd., 1 layer 1 side 7/8" Metal Channels

F1.0 5/8" Gyp. Bd., 1 layer 1 side 1 5/8" Metal Channels

F2.0 5/8" Gyp. Bd., 1 layer 1 side 2 1/2" Metal Studs

F4.0 5/8" Gyp. Bd., 1 layer 1 side 4" Metal Studs

G4.0 5/8" Gyp. Bd., 1 layer ea. side 4" Metal Studs

G4.0L 5/8" Lead-Lined Gyp. Bd., 1 layer ea. side 4" Metal Studs

G4.1 5/8" Fire-Rated Gyp. Bd., 1 layer ea. side 4" Metal Studs 1-HR U419

G4.2 5/8" Fire-Rated Gyp. Bd., 2 layer ea. side 4" Metal Studs 2-HR U419

G6.0 5/8" Gyp. Bd., 1 layer ea. side 6" Metal Studs

M8.2 8" Concrete Masonry Unit 2-HR U905

S2.2 5/8" Fire-Rated Gyp. Bd., 2 layer 1 side, 1" liner panel, shaft side

2 1/2" C-H Studs 2-HR U415

S4.2 5/8" Fire-Rated Gyp. Bd., 2 layer 1 side, 1" liner panel, shaft side

4" C-H Studs 2-HR U415

S6.2 5/8" Fire-Rated Gyp. Bd., 2 layer 1 side, 1" liner panel, shaft side

6" C-H Studs 2-HR U415

ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription

1 05/08/17 Revision 1

2 10/31/17 Revision 2 - Hybrid 2

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:3

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

G002

APPENDIX B & UL

LISTINGS

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH/FF

Salisbury, NC

100% FINAL DESIGN

ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription

1 05/08/17 Revision 1

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:3

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

G003

UL LISTINGS

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

CEILING

STEEL STUDS

UNDERSIDE OF STRUCTURE

GYP WALL BD (5/8")

SEALANT

FLOOR SLAB

SEALANT

*SEAL ALL

PENETRATIONS WITH

SEALANT

TYPE G1.0/G2.0/G3.0/G4.0/G6.0

SCALE: 1-1/2"=1'-0"STC-49 SA870717

/8

G2.0

WITH 2 1/2" STUDS

G4.0

WITH 4" STUDS

G1.0

WITH 1 5/8" STUDS

G6.0

WITH 6" STUDS

SOUND ATTENUATION

INSULATION

BASE AS SCHEDULED

G3.0

WITH 3 5/8" STUDS

3/ 8"

FLOOR SLAB

FIRE SEALANT

STEEL STUDS

@ 16" ON CENTER

FIRE RATED GYP WALL

BD (5/8")

CEILING

*FIRESTOP ALL

PENETRATIONS

TYPE G3.1/G4.1/G6.1, (1-HR)

SCALE: 1-1/2"=1'-0"

STC-49 SA870717

UL-U419 1 HOUR

/8

G4.1

WITH 4" STUDS

G6.1

WITH 6" STUDS

GLASS FIBER OR MINERAL WOOL

INSULATION

M A

X

1/ 4"

FIRE SEALANT

2" M

IN

/ 6

M

A X

FIRE RATED GYP WALL

BD (5/8")

UNDERSIDE OF FLOOR OR ROOF

ASSEMBLY PER U.L. DESIGN NUMBER

BASE AS SCHEDULED

G3.1

WITH 3 5/8" STUDS

SEALANT

FLOOR SLAB

GYP WALL BD (5/8")

UNDERSIDE OF STRUCTURE

TYPE F0.0

SCALE: 1-1/2"=1'-0"

CEILING

3/ 8"

6"

COORDINATE FINAL HEIGHT WITH

WALL SCHEDULE

EXISTING EXTERIOR WALL,

CONCRETE, CMU, OR OTHER

SUBSTRATE - SEE PLANS

7/8" HAT CHANNEL AT 16" O.C. VERTICALLY - SHIM WITH INORGANIC

MATERIAL AS NECESSARY TO COMPENSATE FOR SUBSTRATE

CONSTRUCTION TOLERANCES

SCREWS AS REQ'D

LO

CA

TE

E

DG

E

FU

RR

IN

G

CH

AN

NE

L

W

IT

HI

N

2" O

F

ED

G E

O F

W

AL

L

SEALANT

FLOOR SLAB

GYP WALL BD (5/8")

STEEL STUDS

CEILING

UNDERSIDE OF STRUCTURE

F2.0

WITH 2 1/2" STUDS

SEALANT

TYPE F1.0/F2.0/F3.0/F4.0

SCALE: 1-1/2"=1'-0"

/8

F4.0

WITH 4" STUDS

F1.0

WITH 1 5/8" STUDS

*SEAL ALL

PENETRATIONS WITH

SEALANT

BASE AS SCHEDULED

F3.0

WITH 3 5/8" STUDS

1"

CEILING

STEEL STUDS

UNDERSIDE OF STRUCTURE

GYP WALL BD (5/8")

SEALANT

FLOOR SLAB

SEALANT

*SEAL ALL

PENETRATIONS WITH

SEALANT

TYPE G1.0L/G2.0L/G3.0L/G4.0L/G6.0L, (SEALED)

SCALE: 1-1/2"=1'-0"STC-49 SA870717

/8

G2.0L

WITH 2 1/2" STUDS

G4.0L

WITH 4" STUDS

G1.0L

WITH 1 5/8" STUDS

SOUND ATTENUATION INSULATION

G6.0L

WITH 6" STUDS

LEAD LINING ON O.R. ROOM SIDE OF

PARTITION. 7' HIGH OFF OF FLOOR

1/16" THICK. FINAL LEAD THICKNESS

SHALL BE CONFIRMED BY OWNER'S

DOSIMETRIST ONCE FINAL

DECISION IS MADE ON RADIOLOGY

EQUIPMENT.

BASE AS SCHEDULED

G3.0L

WITH 3 5/8" STUDS

FIRE SEALANT

FLOOR SLAB

CEILING

FIRE RATED

GYP WALL BD (5/8")

STEEL CH STUDS

SHAFTWALL LINER

PANEL (1")

UNDERSIDE OF STRUCTURE

*FIRESTOP ALL

PENETRATIONS

TYPE S2.1/S4.1/S6.1, (1-HR) & S2.2/S4.2/S6.2, (2-HR)

SCALE: 1-1/2"=1'-0"

STC-42

UL-U415 1 HOUR & 2 HOUR

/8

S2.2 (2-HR) SIMILAR W/ TWO (2) LAYERS

OF FIRE RATED GYP WALL BD (5/8")

S4.1 (1-HR) W/ STEEL CH STUDS (4")

S4.2 (2-HR) SIMILAR W/ TWO (2)

LAYERS OF FIRE RATED GYP WALL

BD (5/8") AND STEEL CH STUDS (4")

SHAFTWALL LINER

PANEL (1")

SEALANT SYSTEM COMPLIANT

WITH UL# HW-D-0372

BASE AS SCHEDULED

S2.1 (1-HR) W/ STEEL CH STUDS (2

1/2"")

S4.1 (1-HR) W/ STEEL CH STUDS (6")

S6.2 (2-HR) SIMILAR W/ TWO (2)

LAYERS OF FIRE RATED GYP WALL

BD (5/8") AND STEEL CH STUDS (6")

*FIRESTOP ALL

PENETRATIONS

WALL PRIORITY PLAN & LEGEND

SCALE: 1-1/2"=1'-0"

2-

HR

R

AT

ED

W

AL

L

NON-RATED

WALL

RATED WALL

NO

N-

RA

TE

D W

AL

L

1-HR RATED

WALL

2-HR RATED

WALL

1-HR RATED

WALL

ONE (1) LAYER

OF GYP. BD. AT

1-HR RATED

WALL

HOLLOW METAL FRAME

JAMB STUDS AS REQUIRED

HIGHER PRIORITY WALL

METAL STUDS AS PRESCRIBED

IN WALL SCHEDULE

TWO HOUR FIRE & SMOKE WALL

TWO HOUR FIRE WALL

TWO HOUR SHAFT WALL

ONE HOUR FIRE & SMOKE WALL

ONE HOUR FIRE WALL

NON-RATED WALL

PRIORITY 1 (HIGHEST)

PRIORITY 2

PRIORITY 2

PRIORITY 3

PRIORITY 4

PRIORITY 5 (LOWEST)

WALL PRIORITY LEGEND

2" M

A X

2" MAX.

16 SQ. INCH MAX AT EACH OPENING.

RATED GYP WALL BD

ADJACENT ELECTRICAL BOXES - RATED WALLS

SCALE: NTS

SEAL BOXES TIGHT WITH JOINT

COMPOUND

2 FEET MIN.

*MAXIMUM OPENING PER 100 SQ. FT. IS

LIMITED TO 100 SQ. INCHES*

DATA /

ELEC BOX

DATA /

ELEC BOX

SCREWS AS REQ'D

BOXED HEADER DETAIL

SCALE: NTS

BOXED HEADER, SIZE

AND GAGE AS REQ'D

INSERT INSULATION INTO BOX

WHEN LOCATED ON EXTERIOR

WALL - R VALUE OF INSULATION

TO MATCH ADJACENT WALL

TRACK PIECE, SIZE AND

GAGE AS REQ'D. SCREW

TO JAMB AND LINTEL AS

REQ'D

SCREWS AS REQ'D

JAMB, SIZE AND GAGE

AS REQ'D

SUPPORT CLIP W/

SCREWS AS REQ'D

STUD, SIZE AND GAGE AS REQ'D

GYP WALL BD - SEE WALL SCHEDULE

FOR QUANTITY, SIZE, AND TYPE

PARTITION CORNER DETAIL

SCALE: 3"=1'-0"

SCREWS AS REQ'D

2" M

A X

2" MAX.

STEEL STUDS - SEE WALL SCHEDULE

FOR SIZE AND HEIGHT

GYP WALL BD - SEE WALL SCHEDULE

FOR QUANTITY, SIZE, AND TYPE

SEALANT

WALL CONTROL JOINT

SCALE: 3"=1'-0"

VERTICAL CONTROL JOINT AT 30'

O.C. MAX. UNLESS NOTED

OTHERWISE

INSTALL CONTROL JOINTS AT

GYPSUM BOARD WALLS AND

SOFFITS

GAUGE

SHAPE/TYPE

C-SHAPE

WIDTH

INTERIOR

ALL MECHANICAL SHAFTS SHOULD BE FIRE RATED CONSTRUCTION. AS SHOWN ON PLAN

2-1/2 inch

2-1/2 inch

C-H-SHAPE

C-SHAPE

C-SHAPE

C-SHAPE

1-5/8 inch

3-5/8 inch

4 inch

REFER TO FLOOR PLANS SHEET FOR FIRE RATED AND SMOKE PARTITION LOCATIONS. ALL FIRE & SMOKE PARTITIONS SHALL EXTEND FROM FLOOR SLAB TO THE UNDERSIDE OF STRUCTURE - DECK ABOVE. ALL PENETRATIONS SHALL BE SEALED AND PROTECTED WITH FIRE RATED

SEALANT TO MAINTAIN THE INTEGRITY OF THE PARTITION.

PARTITION INSTALLATION SHALL CONFORM TO ALL CODE REQUIREMENTS.

WHERE PARTITIONS OF DIFFERENT FIRE RATING INTERSECT, PARTITION WITH THE HIGHEST PRIORITY SHALL BE CONTINUOUS PER

FOLLOWING PRIORITY LIST:

PRIORITY 1 - TWO HOUR FIRE AND SMOKE WALL

PRIORITY 2 - TWO HOUR FIRE OR SHAFT WALL

PRIORITY 3 - ONE HOUR FIRE AND SMOKE WALL

PRIORITY 4 - ONE HOUR FIRE WALL

PROVIDE IDENTIFICATION OF ALL FIRE RATED AND/OR SMOKE

PARTITIONS AT NOT MORE THAN 10'-0" ON CENTER ABOVE

CEILINGS WITH 3" HIGH STENCILED BLOCK LETTERING AS

FOLLOWS: "1 HOUR FIRE", "1 HOUR FIRE/SMOKE", "2 HOUR

FIRE", "2 HOUR FIRE/SMOKE", "2 HOUR SHAFT", ETC.

EXTEND FIRE RATED WALL CONSTRUCTION BEHIND RECESSED OR BUILD-IN EQUIPMENT SUCH AS FIRE EXTINGUISHER CABINETS (FEC), ELECTRICAL WATER COOLERS (EWC), ELECTRIC PANELS, ETC.

STAGGER GYPSUM BOARD JOINTS VERTICALLY AND HORIZONTALLY A MINIMUM OF 16" EACH SIDE OF PARTITION AT ALL PARTITIONS.

PROVIDE TYPE 'X' WATER RESISTANT GYPSUM WALL BOARD, ON ALL SURFACES, IN ALL TOILETS, JANITOR CLOSETS AND SHOWERS. PROVIDE TYPE 'X' TILE BACKERBOARD ON ANY PARTITION SCHEDULED TO BE FINISHED WITH CERAMIC TILE.

PROVIDE AND INSTALL ANY STIFFENERS, BRACING, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL

FLOOR MOUNTED OR SUSPENDED MECHANICAL, OR ELECTRICAL.

ALL VERTICAL PIPING AND COLUMNS EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND GWB AND FINISHED TO MATCH

ADJACENT WALLS, U.N.O. EXCEPTIONS: ELEC. CLOSETS, TEL. CLOSETS & MECH. CLOSETS.

WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND/OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL.

COORDINATE METAL STUD GAUGE WITH PRE-APPROVED EQUIPMENT ANCHORAGE. WHERE DISCREPANCY OCCURS, THE MORE STRINGENT

REQUIREMENT SHALL GOVERN.

PROVIDE FIRE SAFING INSULATION AS REQUIRED TO MAINTAIN THE INTEGRITY OF FIRE RATED PARTITIONS.

PROVIDE REQUIRED FRAMES AND BRACING AROUND WALL PENETRATIONS.

PROVIDE CONTINUOUS ACOUSTICAL SEALANT AT BOTTOM OF ALL PARTITIONS.

WHERE COLUMN FURRING STUDS EXCEED THE MANUFACTURER'S RECOMMENDED LIMITING HEIGHTS, STUDS SHALL BE BRACED BACK TO THE

STRUCTURE AS REQUIRED.

METAL STUD SCHEDULE:

UNLESS NOTED OTHERWISE, STRUCTURAL PROPERTIES LISTED BELOW ARE BASED ON STEEL STUDS C-SHAPE STUDS AND SHALL HAVE

MINIMUM 1-1/4" FLANGE WITH 1/4" RETURN LIPS EACH SIDE.

ALL PARTITIONS SHALL RECEIVE SOUND ATTENUATION BLANKETS, EXCEPT FOR PARTITIONS WHICH DO NOT SEPARATE TWO OR MORE

ROOMS (WING WALLS).

THERE SHALL BE NO BACK-TO-BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS, EXCEPT WHERE SPECIFICALLY SHOWN.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

PARTITION NOTES

PRIORITY 5 - NON-RATED WALL

20C-SHAPE6 inch

MIN. THICKNESS

0.0195"

0.0147"

0.0195"

0.0195"

0.0209"

0.0209"

3/8" NOM. MORTAR THICKNESS.

STAGGER VERTICAL JOINTS

FLOOR SLAB

8" CONCRETE MASONRY UNIT:

D-2 (2 HR)

UNDERSIDE OF FLOOR OR ROOF

ASSEMBLY PER U.L. DESIGN NUMBER

SEALANT SYSTEM COMPLIANT WITH

UL# HW-D-0030

TYPE M4.2/M8.2

SCALE: 1-1/2"=1'-0"

M8.0 SIMILAR

WITH NON-RATED CMU AND NON-

RATED SEALANT AT TOP.

M A

X

1"

UL U905

M8.1 SHALL BE CONSTRUCTED IN

LIKE MANNER AS M8.2. OPENING

AND PENETRATION REQUIREMENTS

MAY DIFFER

SEALANT SYSTEM COMPLIANT WITH

UL# WW-D-0022

M

AT

ER

IA

L M

AY

V

AR

Y, S

EE

FL

O

O R

PL

AN

*FIRESTOP ALL

PENETRATIONS

3/ 8"

FLOOR SLAB

FIRE SEALANT

STEEL STUDS (4") @ 16"

ON CENTER

TWO (2) LAYERS FIRE

RATED GYP WALL

BD (5/8")

CEILING

*FIRESTOP ALL

PENETRATIONS

TYPE G4.2, (2-HR)

SCALE: 1-1/2"=1'-0"

STC-49 SA870717

UL-U419 2 HOUR

/8

GLASS FIBER OR MINERAL WOOL

INSULATION

M A

X

1/ 4"

FIRE SEALANT

2" M

IN

/ 6

M

A X

TWO (2) LAYERS FIRE RATED

GYP WALL

BD (5/8")

UNDERSIDE OF FLOOR OR ROOF

ASSEMBLY PER U.L. DESIGN NUMBER

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:4

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

G004

PARTITION TYPES

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

ROOF

BELOW

ROOF

BELOW

ROOF

BELOWROOF

BELOW

CLEAN

ELEVATOR

ELEVATOR

LOBBY

OFFICE

4127B

SUPPLIES /

CLEAN

UTILITY

STAFF

WORKSTATION

STAIRS

MEN'S

LOCKERS

4130A

OR #6

EQUIPMENT

STORAGE #1

HAC

EQ STORAGE

#2

STAIR

OR #7

PACU PH 1

TOILET

SOILED

UTILITY

PRE OP

TOILET

4017B

PH2 / RM1

PH2 / RM2

PH2 / RM4

PH2 / RM3

TOILET / SHW

PH2 / RM5

BED

4029TOILET

4029A

LINEN

STORAGE

DUMBWAITER

VENDING

4154A

PH 1 PACU

TOILET

TOILET

STORAGE

4093TOILET

OFFICE

4100B

OFFICE

4100A

CONFERENCE

RECEPTION

TOILET / SHW

4030A

BED

NEW ELEV

NURSE

STATION

ELEC

IT

ROOF

BELOW

ROOF

BELOW

DEDUCT ALTERNATE #1:

DELETE ALL WORK

ASSOCIATED WITH THE

RENOVATION OF THE OLD

O.R. AREA, SOUTHEAST

WING OF LEVEL 4.

AREA OF DEMOLITION TO

INSTALL SUPPORT

STRUCTURE FOR HYBRID

OR # 2. SEE STRUCTURAL

DRAWINGS.

OR #5

SUB STERILE

MED GAS

SOILED

UTILITY

TOILET

WOMEN'S

LOCKERS

MEN'S

LOCKERS

TOILET

ELECTRICAL

SURGICAL

CORRIDOR

STORAGE

STORAGE

MOP CLOSET

MOP CLOSET

OR #1

SCRUB ROOM

SCRUB RM

STORAGE

MECH

OR #2

OR #3

STAIRS

STORAGE

STORAGE

MOP CLOSET

OR #1

SCRUB ROOM

SCRUB RM

STORAGE

MECH

OR #2

OR #3

STORAGE

SHAFT

SHAFT

SHAFT

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:5

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

G005

DEDUCT ALTERNATE

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

1/8" = 1'-0"

DEDUCT ALTERNATE #1 - FOURTH FLOOR

F

DN

DN

U

U

U

C

K

K

C

LIFE SAFETY LEGEND

Travel Distance 25'-0"

1 Hour Fire Rated Barrier

Exit Width

2 Hour Fire Rated Barrier

Fire Extinguisher Cabinet FEC

Exit Sign

0 1

0"

Egress Width

Actual Occupant Load

Max. Occupant Load

Fire Extinguisher FE

1 Hour Smoke Barrier

2 Hour Smoke Barrier

Smoke Partition

1Key Note

LSTD: Life Safety Suite Travel Distance (50 or 100 ft depending on number of intervening rooms)

EATD: Exit Access Travel Distance (150 ft)

SBTD: Smoke Barrier Travel Distance (200 ft limit)

GENERAL NOTES

1. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL COMPLY

WITH THE BUILDING CODE AND NFPA.

2. PENETRATIONS SHALL BE FIRE STOPPED WITH FIRE BARRIER

PRODUCTS AS REQUIRED TO MAINTAIN FIRE RATINGS. INSTALL IN

ACCORDANCE WITH UL ASSEMBLIES AND MANUFACTURER'S

INSTRUCTIONS FOR THEIR USE.

3. CONTRACTOR MAY USE OTHER UL LISTED FIRE STOP MATERIALS

WHEN APPROVED IN WRITING BY THE ARCHITECT AND FIRE

MARSHAL.

4. PROVIDE SHOP DRAWINGS FOR APPROVAL SHOWING

PENETRATIONS, MATERIALS USED FOR FIRE RATING AND UL

ASSEMBLY NO.

5. PROVIDE BLOCKING AT PARTITIONS AS REQUIRED FOR MOUNTING

OF FURNISHED AND NON-FURNISHED WALL-MOUNTED ITEMS.

6. ALIGN FINISHED FACE OF CONTINUOUS PARTITIONS THAT CHANGE

PARTITION TYPES ALONG A STRAIGHT RUN.

7. PROVIDE SUPPLEMENTAL FRAMING, INSULATION, AND FINISH

MATERIALS AS REQUIRED TO MAINTAIN PARTITION FIRE-RESISTANCE

RATING AT RECESSED ITEMS.

8. REFER TO SHEET A601 FOR DOOR SCHEDULE AND DOOR TYPES.

9. REFER TO SHEET G004 FOR PARITION TYPE DETAILS

NURSE STATION

PACU PH 1

NEW ELEV

EQ ALCOVE

SUPPLIES / CLEAN

UTILITY

TOILET

SOILED UTILITY

MEN'S LOCKERS

4130A

WOMEN'S

LOCKERS

ELECTRICAL

PRE OP

STORAGE

4017A

TOILET

4017B

PH2 / RM1

PH2 / RM2

TOILET / SHW

PH2 / RM3

PH2 / RM4

PH2 / RM5

BED

BED

BED

TOILET / SHW

4030A

TOILET

4029A

STORAGE

LINEN

4156MECH

VENDING

4154ADUMBWAITER

OR #1

CLEAN CORE

STERILE SUPPLY

SOIL HOLD

SHOWER

TOILET

TOILET

STAIRS

LINEN CHUTE

SOILED UTILITY

MED GAS

OR #5

SUB STERILE

OR #6

ELEVATOR LOBBY

OFFICE

4127B

STAFF

WORKSTATION

RELOCATED

NEPTUNE DOCK

OR #7

EQ STORAGE #2

STAIR

EQUIPMENT

STORAGE #1

4119 HAC

ELECTRICAL

SURGICAL

CORRIDOR

CLEAN

ELEVATOR

STAIRS

EQ. STORAGE

OR #2

CYSTO STORAGE

SCRUB #2

SCRUB #1

HAC

MEN'S LOCKERS

OFFICE

4100A

PH 1 PACU

OFFICE

4100B

TOILET

CONFERENCE

RECEPTION

STORAGE

4093TOILET

TOILET

ELEC

IT

0'

0"

BED

BED

TOILET / SHW

TOILET / SHW

BED

BED

SCRUB

CORRIDOR

NEPTUNE DOCK

C-ARM ALCOVE

HAC

STORAGE

TOILET

Room

ELEC

TOILET

UTILITY

OFFICE

TOILET

PASS

SURGERY

WAITING

OFFICE

4076Room

STAIR # 6

NOURISHMENT

ROOM

CONTROL

BREAKROOM

SOIL UTILITY

MED ROOM

ICU

ICU

STORAGE

ICU

ICU

STAIR #2

ICU

ICU

DISTRIBUTION

ICU

ISOLATION ICU

ANTE

ISOLATION ICU

ICU

Room

HAC

STAFF TOILET

LOCKER ROOM

ON CALL

TOILET

STORAGE

BREAK / CONF

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

STAIR #3

OFFICE

OFFICE

OFFICE

OFFICE

RESP EQ

RESP OFFICE

CLEAN LINEN

EQUIP

FEC

FEC

ELEC

F.A,C.

137 45

41"

143 14

43"

10343 SF

SMOKE

COMPARTMENT

4-1

10778 SF

SMOKE

COMPARTMENT

4-2

10445 SF

SMOKE

COMPARTMENT

4-3

Occupancy Classifications

SMOKE COMPARTMENT 4-1

SMOKE COMPARTMENT 4-2

SMOKE COMPARTMENT 4-3

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:0

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

GL101

OVERALL FOURTH

FLOOR LIFE SAFETY

PLAN

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

1/16" = 1'-0"

FOURTH FLOOR OVERALL LIFE SAFETY PLAN

1/32" = 1'-0"

FOURTH FLOOR SMOKE COMPARTMENT PLAN

UP

F

F

S D

F

UP UP

C

K

N

V

K

E

J

Q

N

C

C

D

B

C

D

D

B

LIFE SAFETY LEGEND

Travel Distance 25'-0"

1 Hour Fire Rated Barrier

Exit Width

2 Hour Fire Rated Barrier

Fire Extinguisher Cabinet FEC

Exit Sign

0 1

0"

Egress Width

Actual Occupant Load

Max. Occupant Load

Fire Extinguisher FE

1 Hour Smoke Barrier

2 Hour Smoke Barrier

Smoke Partition

1Key Note

LSTD: Life Safety Suite Travel Distance (50 or 100 ft depending on number of intervening rooms)

EATD: Exit Access Travel Distance (150 ft)

SBTD: Smoke Barrier Travel Distance (200 ft limit)

GENERAL NOTES

1. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL COMPLY

WITH THE BUILDING CODE AND NFPA.

2. PENETRATIONS SHALL BE FIRE STOPPED WITH FIRE BARRIER

PRODUCTS AS REQUIRED TO MAINTAIN FIRE RATINGS. INSTALL IN

ACCORDANCE WITH UL ASSEMBLIES AND MANUFACTURER'S

INSTRUCTIONS FOR THEIR USE.

3. CONTRACTOR MAY USE OTHER UL LISTED FIRE STOP MATERIALS

WHEN APPROVED IN WRITING BY THE ARCHITECT AND FIRE

MARSHAL.

4. PROVIDE SHOP DRAWINGS FOR APPROVAL SHOWING

PENETRATIONS, MATERIALS USED FOR FIRE RATING AND UL

ASSEMBLY NO.

5. PROVIDE BLOCKING AT PARTITIONS AS REQUIRED FOR MOUNTING

OF FURNISHED AND NON-FURNISHED WALL-MOUNTED ITEMS.

6. ALIGN FINISHED FACE OF CONTINUOUS PARTITIONS THAT CHANGE

PARTITION TYPES ALONG A STRAIGHT RUN.

7. PROVIDE SUPPLEMENTAL FRAMING, INSULATION, AND FINISH

MATERIALS AS REQUIRED TO MAINTAIN PARTITION FIRE-RESISTANCE

RATING AT RECESSED ITEMS.

8. REFER TO SHEET A601 FOR DOOR SCHEDULE AND DOOR TYPES.

9. REFER TO SHEET G004 FOR PARITION TYPE DETAILS

HYBRID 2

FEMALE

LOCKERS

SCRUB

MECH

5003 EQ. STORAGE

STAFF TOILET

5007A

5008A

5008B

5008C PATIENT TOILET

ISOLATION

EXAM #2

BREAK RM

PHARM

NEW ELEV.

NS

CLEAN/ MEDS

IV MIXTURE ROOM

5110 ALCOVE

DUMBWAIT

ECHO READING

ECHO STATION

5068A

ECHO STATION

TEE/ CARDIO

STAIRS

NS WORK

5077STERILE SUPPLY

MALE LOCKERS

SCRUB

SOIL

5007B

SEMI - HYBRID 1

MECH

ELEVATOR LOBBY

5077B

CLEAN ELEVATOR

5077E

HK

ROOF

ROOF

ROOF

ROOF

IT

ELEC

TELE

LINEN

EXAM #3

EXAM #1

WAITING

STORAGE

ELEC

HEALTH ADMIN

ELEC

TOILET

TOILET

EQUIP. STOR

CLEAN CORE

SOILED

ANESTH. OFFICE

ANESTH WORK/

SUPPLY

ANTE

5010A

NURSE COORD.

5062C

EXG/ HOLTER

5062B

EKG/ HOLTER

5062A

HAC

EXAM #4

EXAM #5

EXAM #6

EXAM #7

NURSE MANAGER

MOBILE C-ARM

CORRIDOR

PREOP - RECOV

PROCEDURE

TOILET ROOM

5020B

PROCEDURE

ROOM

5020A

TOILET

MED ROOM

SCOPE CLEAN

Room

SPD

TOILET

F. TLT

ELEC

STAIRS

L. CHUTE

WO CLINIC WAIT

SOILED

SPD

NOUR. KIT.

TOILET

OFFICE

NA52

EXAM

OFFICE/ EXAM

OFFICE/ EXAM

OFFICE/ EXAM

OFFICE/ EXAM

5039ATOILET/ SHOWER

OFFICE/ EXAM

ULTRASOUND

UTILITY

BREAK ROOM

PIPE SPACE

OFFICE

NURSE TRIAGE

PIPE SPACE

WORKROOM

STORAGE

M & F TOILET

EXAM #5

DR. HENRY

5027A

SERVICE CHIEF

5026A

EXAM #4

EXAM #3

5025A

EXAM #2

SHARED OFFICE

UROLOGY

WAITING

STRETCHER

ALCOVE

EQ ALCOVE

EQ

FEC

FEC

137 51

41"

137 51

41"

CONTROL ROOM

5001A

7035 SF

SMOKE

COMPARTMENT

5-1

7090 SF

SMOKE

COMPARTMENT

5-3

10145 SF

SMOKE

COMPARTMENT

5-2

Occupancy Classifications

SMOKE COMPARTMENT 5-1

SMOKE COMPARTMENT 5-2

SMOKE COMPARTMENT 5-3

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/2 /2

:5

:4

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th .c ru m p .r v t

GL102

OVERALL FIFTH FLOOR

LIFE SAFETY PLAN

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

1/16" = 1'-0"

FIFTH FLOOR OVERALL LIFE SAFETY PLAN

1/32" = 1'-0"

FIFTH FLOOR SMOKE COMPARTMENT PLAN

ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription

1 05/08/17 Revision 1

2 10/31/17 Revision 2 - Hybrid 2

OVA

UP

UP UP UP

U2

U1

U1

B5

B6

C8

K1

K1

B5

B6

C8

U2

U1

U1

B5

B6

C8

K1

K1

B5

B6

C8

UP

B3

B4

C6 K1

N4

V1

K1

E1

J1

Q1

N2

C4

C1

B2

C3

D1

B1

UP

B3

B4

C6 K1

N4

V1

K1

E1

J1

Q1

N2

C4

C1

B2

C3

D1

B1

UP

B3

B4

C6 K1

N4

V1

K1

E1

J1

Q1

N2

C4

C1

B2

C3

D1

B1

OVA

SEE DEMO PLAN AD101A -

LEVEL 3.

RE-ROUTE ALL UTILITIES TO

ACCOMMODATE NEW

ELEVATOR SHAFT.

SEE DEMO PLAN AD102A -

LEVEL 4.

RE-ROUTE ALL UTILITIES TO

ACCOMMODATE NEW

ELEVATOR SHAFT

SEE DEMO PLAN

AD102A - LEVEL 4,

THIS AREA ONLY.

THIS AREA WIL BE IMPACTED

DURING DEMOLITION WORK

ON LEVEL 5 ABOVE.

SEE DEMO PLAN AD103A -

LEVEL 5.

RE-ROUTE ALL UTILITIES TO

ACCOMMODATE NEW

ELEVATOR SHAFT.

SEE DEMO PLAN AD-104A -

MECHANICAL/ ROOF LEVEL.

RE-ROUTE ALL UTILITIES TO

ACCOMMODATE NEW

ELEVATOR SHAFT OVER-RIDE.

SEE SHEET A101A - LEVEL 3

FOR NEW ELEV PIT WORK

THIS AREA.

THIS AREA WILL BE

IMPACTED DURING

DEMOLITION WORK ON

LEVEL 4 ABOVE.

THIS AREA WILL BE

IMPACTED DURING

DEMOLITION WORK ON

LEVEL 4 ABOVE.

(ELECTRICAL, PLUMBING,

DRAIN LINES, ETC.)

SEE SHEET A102A - LEVEL 4

FOR NEW WORK THIS AREA.

THIS AREA WILL BE

IMPACTED DURING

CONSTRUCTION OF NEW

WORK ON LEVEL 5

ABOVE, (ELECTRICAL,

PLUMBING, DRAIN LINES,

ETC.)

NEW STEEL SUPPORTS UNDER

C-ARM ABOVE. (HYBRID #2)

SEE STRUCTURAL DRAWINGS.

SEE DEMO PLAN AD102A,

LEVEL 4. LEAVE AREA

OPERATIONAL AS LONG

AS POSSIBLE.

COORDINATE TIMING

WITH AHU EXCHANGE.

PHASE 2.3

SEE SHEET A102A -

LEVEL 4 FOR NEW

WORK THIS AREA.

THIS AREA OFF-LINE

WHEN AHU ABOVE IS

REPLACED.

SEE SHEET A103A FOR NEW

WORK THIS AREA.

EXCHANGE AIR

HANDLING UNIT. SEE

MECHANICAL FOR NEW

WORK THIS AREA.

COORDINATE TIMING

W/ OWNER

THIS AREA BUILT, BUT

CONDITIONED FROM A

TEMPORARY SOURCE, SEE

MECH. DWGS.

AREA NOT OPERATIONAL

UNTIL AFTER AHU IS

EXCHANGED IN PHASE 4.

5TH FLOOR HAS TO BE COMPLETED WITH

RENOVATION PRIOR TO BRINGING DOWN

4TH FLOOR FOR DEMOLITION WORKS.

PHASE 2.1

PHASE 2.2

EXCHANGE AIR

HANDLING UNIT. SEE

MECHANICAL FOR NEW

WORK THIS AREA.

COORD. TIMING WITH

OWNER.

AHU CONNECTION

ALLOWS THIS AREA TO

BECOME OPERATIONAL.

SEE SHEET A104A

FOR NEW WORK

THIS AREA

DEMOLITION

NEW

PHASING LEGEND

IMPACTED AREA

OPERATIONAL O.R.

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/2 /2

:0

:2

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th .c ru m p .r v t

PH101

PHASING

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

PHASE 1 PHASE 2 PHASE 3 PHASE 4

LEVEL

LEVEL

LEVEL

MECHANICAL/

ROOF

LEVEL

LEVEL

LEVEL

MECHANICAL/

ROOF

LEVEL

LEVEL

LEVEL

MECHANICAL/

ROOF

LEVEL

LEVEL

LEVEL

MECHANICAL/

ROOF

6 FUNCTIONING

O.R.'S DURING

THIS PHASE

3 FUNCTIONING

O.R.'S DURING

THE LAST PART OF

THIS PHASE

4 FUNCTIONING

O.R.'S DURING

THIS PHASE

6 FUNCTIONING

O.R.'S DURING

THIS PHASE. 7

WHEN FINISHED.

7TH O.R.

OPENS AT

THE END OF

PHASE 4.

ItemItemItemItem DateDateDateDate DescriptionDescriptionDescriptionDescription

1 05/08/17 Revision 1

2 10/31/17 Revision 2 - Hybrid 2

UTILITY

ROOM

EKG

3153 ICE

DAYROOM

OFFICE

3101A

OFFICE

FAC

3165A

1-BED

1-BED

M. TOILET

M. TOILET

1-BED

SPACE

TLT

SPACE

CORRIDOR

STORAGE

STORAGE

1-BED

TLT

TLT

OFFICE

3094K

SUPPLY

OFFICE

3094G

OFFICE

3094H

OFFICE

3094I

OFFICE

3094J

OFFICE

3094F

OFFICE

3094E

SPACE

3094D

OFFICE

3094L

OFFICE

3094C

OFFICE

3094B

OFFICE

3094A

F. TLT.

LAB ST.

TEL

3091A

FAC

TLT

WAITING

3088 STORAGE

M. TLT

1-BED

TLT

TLT

EXAM

STAIR #5

SOILED

LINEN

1-BED

TLT

TLT

1-BED

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE

BEEN PREPARED USING "AS-DESIGNED" DOCUMENTS PROVIDED BY THE OWNER.

NEITHER THE OWNER NOR THE ARCHITECT WARRANT THESE TO BE "AS-BUILT"

DOCUMENTS, AND ACTUAL CONDITIONS MAY VARY. THE DEMOLITION WORK

INDICATED IS INTENDED TO SHOW THE GENERAL SCOPE OF THE DEMOLITION WORK

AND IN NO WAY RELIEVES THE CONTRACTOR FROM PERFORMING ANY AND ALL

DEMOLITION REQUIRED TO COMPLETE THE NEW WORK.

2. ALL DEMOLITION WORK SHALL BE PERFORMED WITH "DUE CARE AND DILIGENCE"

SO AS TO PREVENT THE ARBITRARY DESTRUCTION OR INTERRUPTION OF

CONCEALED UTILITIES WHICH COULD NOT BE PREDETERMINED UNTIL DEMOLITION

WAS STARTED. ALL SUCH DISCOVERIES OF UTILITIES DURING THE DEMOLITION

PROCESS WHICH ARE IN A LOCATION DIFFERENT FROM FLOOR TO FLOOR, ETC., OR

ARE UNIDENTIFIED, SHALL BE REPORTED TO THE ARCHITECT BEFORE REMOVAL FOR

FINAL DISPOSITION.

3. REMOVE ALL CONSTRUCTION DESIGNATED TO BE REMOVED AND CLEAR TO

RECEIVE NEW WORK AS HEREIN INDICATED.

4. REMOVE PORTIONS OF EXISTING CONSTRUCTION AS DRAWN AND PATCH TO

MATCH ADJACENT CONSTRUCTION.

5. WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE

REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGARS, BRACING,

FOUNDATION, ETC. AFTER REMOVAL, AFFECTED CONSTRUCTION AND SURFACES,

SUCH AS FLOORS ,WALLS, BASES, AND CEILINGS, SHALL BE FINISHED TO MATCH

ADJACENT SURFACES UNLESS OTHERWISE NOTED.

6. NEW WORK SHALL ALIGN WITH AND MATCH EXISTING WORK EXCEPT WHERE

OTHERWISE DIMENSIONED OR DETAILED.

7. ANY EXISTING CONDITIONS WHICH ARE INCONSISTENT WITH CONTRACT DRAWINGS

RELEVANT TO THIS CONTRACT SHALL BE REPORTED TO THE ARCHITECT.

8. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR SURFACES WITH

IMPERFECTIONS OR NOT LEVEL TO TOLERANCES SPECIFIED FOR NEW WORK,

PROVIDE SELFLEVELING UNDERLAYMENT.

9. WHERE DEMOLITION WORK UNCOVERS OR LEAVES OPENINGS IN PARTITIONS OR

INCOMPLETE PARTITIONS, EXTEND, RESTORE, AND/OR CLOSE OPENING IN PARTITION

AS INDICATED AND/OR AS REQUIRED TO MAINTAIN FIRE RATINGS AND SMOKE

BARRIERS. MATCH EXISTING CONSTRUCTION, U.N.O., WITHIN THE LIMITS AND

TOLERANCES FOR MATERIALS AS SPECIFIED OR RECOMMENDED BY THE

MANUFACTURER. REFINISH SURFACES TO ALIGN FLUSH WITH EXISTING.

10. WHERE DEMOLITION WORK OR RELOCATION OF EXISTING ITEMS LEAVES

UNFINISHED SURFACES AND/OR SUBSTRATES, CUT AND PATCH AS REQUIRED TO

RESTORE SUBSTRATE AND/OR FINISH MATERIAL EVEN AND FLUSH WITH ADJOINING

SURFACES. TEXTURE AND REFINISH TO MATCH EXISTING U.N.O.

11. CONTRACTOR SHALL DISPOSE OF ALL ITEMS AND MATERIALS PER

SPECIFICATIONS. OWNER RESERVES THE RIGHT TO SELECT SPECIFIC ITEMS FOR

SALVAGE. THESE ITEMS SHALL BE IDENTIFIED DURING A PRECONSTRUCTION

WALKTHROUGH.

12. FOR FURTHER DEMOLITION INFORMATION REF THE MECHANICAL, ELECTRICAL

AND PLUMBING DRAWINGS.

13. APPLY SELF-LEVELING COMPOUND TO FLOORING WHERE CMU WALLS ARE

DEMOLISHED. GRIND FLOOR PRIOR TO APPLYING SELF-LEVELING COMPOUND IF

REQUIRED TO ALLOW FOR LEVEL FLOOR SURFACE. REFER TO DETAIL 8/S401.

14. PROVIDE TEMPORARY DUST, SIGHT AND SOUND BARRIERS AS REQUIRED BY

OWNER, AND WHEREVER NECESSARY, TO LIMIT THE AMOUNT OF NOISE, DUST,

VISUAL POLLUTION WITHIN AND AROUND THE FACILITY, TO MAINTAIN OCCUPANCY

AND USE OF OCCUPIED AREAS IN THE EXISTING BUILDING. THE EXACT LOCATION

AND QUANTITY OF TEMPORARY BARRIERS IS TO BE COORDINATED WITH OWNER AND

DETERMINED BY CONSTRUCTION SCHEDULE AND WORK SCHEDULE.

15. COORDINATE CEILING DEMOLITION WITH TEMPORARY CONSTRUCTION BARRIERS.

16. ALL BUILDING SYSTEMS SERVING OCCUPIED AREAS OF THE BUILDING SHALL

REMAIN FULLY OPERATIONAL AT ALL TIMES. CONTRACTOR SHALL PROTECT AND

MAINTAIN ALL EXISTING BUILDING SYSTEMS INCLUDING SYSTEMS PASSING THROUGH

AND ADJACENT AREAS REQUIRING DEMOLITION. WHERE NECESSARY RE-ROUTE OR

CAP AS REQUIRED ALL WIRING, CONDUITS, PIPING, DUCTWORK AND OTHER UTILITIES

TO SERVE OCCUPIED AREAS.

DEMOLITION PLAN

NOTES

1 REMOVE WALLS, DOORS, CEILINGS, CASEWORK, FIXTURES,

ETC. AS REQUIRED FOR NEW WORK.

2 REMOVE FIXTURES AS REQUIRED FOR NEW WORK. DISCARD

ITEMS AND CAP WATER LINES.

3 FLOOR DEMOLITION FOR NEW ELEVATOR SHAFT.

4 EXISTING UTILITIES TO REMAIN, UNLESS DIRECTED BY MEP

DOCUMENTS TO BE REMOVED. REMOVE EXISTING

ENCLOSURE. USE F2.0 TO WRAPT TIGHT TO STRUCTURE AND

UTILITIES.

DOOR TAG

ROOM TAG

1 REVISION TAG

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

KEYNOTE TAG

SECTION TAG

WALL TAG

A101

SIM

1 DETAIL TAG

INTERIOR ELEVATION TAG

REFERENCE LEGEND

CARD READER

Room

G3.0

101A

EXTERIOR ELEVATION TAG

?1

A101 1

A101 1

1 Hour Smoke Barrier

0 Hour Smoke Resistant

2 Hour Fire Rated Barrier

1 Hour Fire Rated Barrier

2 Hour Smoke Barrier

EXISTING WALL

DEMOLISHED

WALL

NEW WALL

EXISTING DOOR

DEMOLISHED

DOOR

NEW DOOR

ROOM TAG EXISTING

Room

A101a

SIM

CR

WAVE PLATEWP

THE OWNER (VA) HAS VERY SPECIFIC

REQUIREMENTS REGARDING CONSTRUCTION

AND DEMOLITION NOISE, SOUND AND

VIBRATION. SEVERE RESTRICTIONS ARE IN

PLACE REGARDING ACCEPTABLE DECIBEL

LEVELS, DAYS OF OPERATION, HOURS OF

THE DAY, DURATIONS, AND PROXIMITY TO

OCCUPIED SPACES. CONTRACTOR IS

REQUIRE TO INVESTIGATE, FULLY

UNDERSTAND, PLAN FOR, AND COMPLY WITH

THESE RESTRICTIONS, AND ACCOUNT FOR

ANY AND ALL RELATED COST IN THEIR BID.

NOTE:

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:0

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

AD101A

THIRD FLOOR -

DEMOLITION PLAN -

AREA A

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

1/8" = 1'-0"

THIRD FLOOR - DEMOLITION PLAN

O VA

DEMOLITION PLAN

NOTES

1 REMOVE WALLS, DOORS, CEILINGS, CASEWORK, FIXTURES,

ETC. AS REQUIRED FOR NEW WORK.

2 REMOVE FIXTURES AS REQUIRED FOR NEW WORK. DISCARD

ITEMS AND CAP WATER LINES.

3 FLOOR DEMOLITION FOR NEW ELEVATOR SHAFT.

4 EXISTING UTILITIES TO REMAIN, UNLESS DIRECTED BY MEP

DOCUMENTS TO BE REMOVED. REMOVE EXISTING

ENCLOSURE. USE F2.0 TO WRAPT TIGHT TO STRUCTURE AND

UTILITIES.

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE

BEEN PREPARED USING "AS-DESIGNED" DOCUMENTS PROVIDED BY THE OWNER.

NEITHER THE OWNER NOR THE ARCHITECT WARRANT THESE TO BE "AS-BUILT"

DOCUMENTS, AND ACTUAL CONDITIONS MAY VARY. THE DEMOLITION WORK

INDICATED IS INTENDED TO SHOW THE GENERAL SCOPE OF THE DEMOLITION WORK

AND IN NO WAY RELIEVES THE CONTRACTOR FROM PERFORMING ANY AND ALL

DEMOLITION REQUIRED TO COMPLETE THE NEW WORK.

2. ALL DEMOLITION WORK SHALL BE PERFORMED WITH "DUE CARE AND DILIGENCE"

SO AS TO PREVENT THE ARBITRARY DESTRUCTION OR INTERRUPTION OF

CONCEALED UTILITIES WHICH COULD NOT BE PREDETERMINED UNTIL DEMOLITION

WAS STARTED. ALL SUCH DISCOVERIES OF UTILITIES DURING THE DEMOLITION

PROCESS WHICH ARE IN A LOCATION DIFFERENT FROM FLOOR TO FLOOR, ETC., OR

ARE UNIDENTIFIED, SHALL BE REPORTED TO THE ARCHITECT BEFORE REMOVAL FOR

FINAL DISPOSITION.

3. REMOVE ALL CONSTRUCTION DESIGNATED TO BE REMOVED AND CLEAR TO

RECEIVE NEW WORK AS HEREIN INDICATED.

4. REMOVE PORTIONS OF EXISTING CONSTRUCTION AS DRAWN AND PATCH TO

MATCH ADJACENT CONSTRUCTION.

5. WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE

REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGARS, BRACING,

FOUNDATION, ETC. AFTER REMOVAL, AFFECTED CONSTRUCTION AND SURFACES,

SUCH AS FLOORS ,WALLS, BASES, AND CEILINGS, SHALL BE FINISHED TO MATCH

ADJACENT SURFACES UNLESS OTHERWISE NOTED.

6. NEW WORK SHALL ALIGN WITH AND MATCH EXISTING WORK EXCEPT WHERE

OTHERWISE DIMENSIONED OR DETAILED.

7. ANY EXISTING CONDITIONS WHICH ARE INCONSISTENT WITH CONTRACT DRAWINGS

RELEVANT TO THIS CONTRACT SHALL BE REPORTED TO THE ARCHITECT.

8. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR SURFACES WITH

IMPERFECTIONS OR NOT LEVEL TO TOLERANCES SPECIFIED FOR NEW WORK,

PROVIDE SELFLEVELING UNDERLAYMENT.

9. WHERE DEMOLITION WORK UNCOVERS OR LEAVES OPENINGS IN PARTITIONS OR

INCOMPLETE PARTITIONS, EXTEND, RESTORE, AND/OR CLOSE OPENING IN PARTITION

AS INDICATED AND/OR AS REQUIRED TO MAINTAIN FIRE RATINGS AND SMOKE

BARRIERS. MATCH EXISTING CONSTRUCTION, U.N.O., WITHIN THE LIMITS AND

TOLERANCES FOR MATERIALS AS SPECIFIED OR RECOMMENDED BY THE

MANUFACTURER. REFINISH SURFACES TO ALIGN FLUSH WITH EXISTING.

10. WHERE DEMOLITION WORK OR RELOCATION OF EXISTING ITEMS LEAVES

UNFINISHED SURFACES AND/OR SUBSTRATES, CUT AND PATCH AS REQUIRED TO

RESTORE SUBSTRATE AND/OR FINISH MATERIAL EVEN AND FLUSH WITH ADJOINING

SURFACES. TEXTURE AND REFINISH TO MATCH EXISTING U.N.O.

11. CONTRACTOR SHALL DISPOSE OF ALL ITEMS AND MATERIALS PER

SPECIFICATIONS. OWNER RESERVES THE RIGHT TO SELECT SPECIFIC ITEMS FOR

SALVAGE. THESE ITEMS SHALL BE IDENTIFIED DURING A PRECONSTRUCTION

WALKTHROUGH.

12. FOR FURTHER DEMOLITION INFORMATION REF THE MECHANICAL, ELECTRICAL

AND PLUMBING DRAWINGS.

13. APPLY SELF-LEVELING COMPOUND TO FLOORING WHERE CMU WALLS ARE

DEMOLISHED. GRIND FLOOR PRIOR TO APPLYING SELF-LEVELING COMPOUND IF

REQUIRED TO ALLOW FOR LEVEL FLOOR SURFACE. REFER TO DETAIL 8/S401.

14. PROVIDE TEMPORARY DUST, SIGHT AND SOUND BARRIERS AS REQUIRED BY

OWNER, AND WHEREVER NECESSARY, TO LIMIT THE AMOUNT OF NOISE, DUST,

VISUAL POLLUTION WITHIN AND AROUND THE FACILITY, TO MAINTAIN OCCUPANCY

AND USE OF OCCUPIED AREAS IN THE EXISTING BUILDING. THE EXACT LOCATION

AND QUANTITY OF TEMPORARY BARRIERS IS TO BE COORDINATED WITH OWNER AND

DETERMINED BY CONSTRUCTION SCHEDULE AND WORK SCHEDULE.

15. COORDINATE CEILING DEMOLITION WITH TEMPORARY CONSTRUCTION BARRIERS.

16. ALL BUILDING SYSTEMS SERVING OCCUPIED AREAS OF THE BUILDING SHALL

REMAIN FULLY OPERATIONAL AT ALL TIMES. CONTRACTOR SHALL PROTECT AND

MAINTAIN ALL EXISTING BUILDING SYSTEMS INCLUDING SYSTEMS PASSING THROUGH

AND ADJACENT AREAS REQUIRING DEMOLITION. WHERE NECESSARY RE-ROUTE OR

CAP AS REQUIRED ALL WIRING, CONDUITS, PIPING, DUCTWORK AND OTHER UTILITIES

TO SERVE OCCUPIED AREAS.

PH2 / RM4

PH2 / RM2

PH2 / RM1

TOILET

4017B

PRE OP

ELECTRICAL

STORAGE

4017A

TOILET

TOILET

MEN'S

LOCKERS

4130A

STAIRS

SUPPLIES /

CLEAN

UTILITY

TOILET

STAFF

WORKSTATION

OFFICE

4127B

CLEAN

ELEVATOR

ELEVATOR

LOBBY

SURGICAL

CORRIDOR

OR #6

OR #7

HAC

EQUIPMENT

STORAGE #1

EQ STORAGE

#2

4122STAIR

SUB STERILE

OR #5

MED GAS

SOILED

UTILITY

WOMEN'S

LOCKERS

SHOWER

LINEN CHUTE

PACU PH 1

DUMBWAITER

VENDING

4154A

LINEN

STORAGE

MECH

TOILET / SHW

PH2 / RM3

PH2 / RM5

BED

4029TOILET

4029A

BED

SOILED

UTILITY

STAIRS

MEN'S

LOCKERS

SHOWER

4130B

SCRUB #2

SCRUB #1

MINOR OR

REGISTRATION

ELEC

4152B

MINOR OR

NURSE

STATION

CASE CART

HOLDING

STORAGE

STORAGE

MOP CLOSET

MOP CLOSET

OR #1

SCRUB ROOM

SCRUB RM 4002

MECH

STORAGE

MECH

STORAGE

OR #2

OR #34138

FAC

4113A

PAT LOCKER

CLOSET

OFFICE

4100A

OFFICE

4100B

PH 1 PACU

TOILET

CONFERENCE

RECEPTION

STORAGE

TOILET

TOILET

TOILET / SHW

4030A

ROOF

BELOW

ROOF

BELOW

ROOF

BELOW

ROOF

BELOW

F.A,C.

ELEC

DOOR TAG

ROOM TAG

1 REVISION TAG

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

KEYNOTE TAG

SECTION TAG

WALL TAG

A101

SIM

1 DETAIL TAG

INTERIOR ELEVATION TAG

REFERENCE LEGEND

CARD READER

Room

G3.0

101A

EXTERIOR ELEVATION TAG

?1

A101 1

A101 1

1 Hour Smoke Barrier

0 Hour Smoke Resistant

2 Hour Fire Rated Barrier

1 Hour Fire Rated Barrier

2 Hour Smoke Barrier

EXISTING WALL

DEMOLISHED

WALL

NEW WALL

EXISTING DOOR

DEMOLISHED

DOOR

NEW DOOR

ROOM TAG EXISTING

Room

A101a

SIM

CR

WAVE PLATEWP

THE OWNER (VA) HAS VERY SPECIFIC

REQUIREMENTS REGARDING CONSTRUCTION

AND DEMOLITION NOISE, SOUND AND

VIBRATION. SEVERE RESTRICTIONS ARE IN

PLACE REGARDING ACCEPTABLE DECIBEL

LEVELS, DAYS OF OPERATION, HOURS OF

THE DAY, DURATIONS, AND PROXIMITY TO

OCCUPIED SPACES. CONTRACTOR IS

REQUIRE TO INVESTIGATE, FULLY

UNDERSTAND, PLAN FOR, AND COMPLY WITH

THESE RESTRICTIONS, AND ACCOUNT FOR

ANY AND ALL RELATED COST IN THEIR BID.

NOTE:

This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.

It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.

It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.

Project

City, State

RPA Design Project Number

Drawn By

Checked By

Seal / Signature

Sheet Title

Date

Sheet Number

Issued For

Architect of RecordArchitect of RecordArchitect of RecordArchitect of Record

5960 Fairview Road

Suite 500

Charlotte, NC 28210

887.3500

887.3507 fax

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212

704.531.3000 PHONE

704.531.3001 FAX

MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:

Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031

704.987.9114 PHONE

704.987.9938 FAX

STRUCTURAL:

Program ManagerProgram ManagerProgram ManagerProgram Manager

13620 Reese Blvd.

Suite 100

Huntersville, NC 28078

401.2040

401.2067 fax

/9

/2

:4

:0

A

M C

U s e rs \e liz a b e th

.s u m n e r\

D o c u m e n ts

\1 -0

-0

B

L D

G

O

R R e n o v

C e liz a b e th

.s u m n e r@ rp a d e s ig n .n e t.

rv t

AD102A

FOURTH FLOOR -

DEMOLITION PLAN -

AREA A

15-0014-00

CORRECT OPERATING

ROOM DEFICIENCIES

11/10/16

ES

RH

Salisbury, NC

100% FINAL DESIGN

1/8" = 1'-0"

FOURTH FLOOR - DEMOLITION PLAN

BREAK RM

EXAM #2

IV MIXTURE

ROOM

ALCOVE

DUMBWAIT

STORAGE

ELEC

ECHO

READING

ECHO

STATION

5068A

ECHO

STATION

ELEC

STAIRS

TEE/ CARDIO

MECH

ELEVATOR

LOBBY

5077B

MECH

WAITING

HEALTH

ADMIN

5060 EXAM #3

EXAM #1

PHARM

TELE

SOILED

LINEN

STRESS

TESTING

STRESS

TESTING

NURSING

EDU.

CLASSROOM

LOCKER5006

TOILET

OFFICE

OFFICE

OFFICE

5095A

PIPE CHASE

TOILET

PIPE CHASE

NURSING ED.

EQ. STORAGE

OFFICE5090

OFFICE

BREAK ROOM

HAC

OFFICE

OFFICE

OFFICE 5077

CORRIDOR

WAITING

TOILET

STORAGE

UTILITIES

OFFICE

STORAGE

STORAGE

CHG RM

HAC

5081A

ELEC

FAC

5005A

ELEC

LINEN

EXG/ HOLTER

5062B

EKG/ HOLTER

5062A

NURSE

COORD.

5062C

HAC

TOILET

OFFICE

OFFICE

5077E

SERVICE

ELEVATOR

EXAM #1

ROOF

ROOF

AD103A

AD103A

DEMOLITION PLAN

NOTES

1 REMOVE WALLS, DOORS, CEILINGS, CASEWORK, FIXTURES,

ETC. AS REQUIRED FOR NEW WORK.

2 REMOVE FIXTURES AS REQUIRED FOR NEW WORK. DISCARD

ITEMS AND CAP WATER LINES.

3 FLOOR DEMOLITION FOR NEW ELEVATOR SHAFT.

4 EXISTING UTILITIES TO REMAIN, UNLESS DIRECTED BY MEP

DOCUMENTS TO BE REMOVED. REMOVE EXISTING

ENCLOSURE. USE F2.0 TO WRAPT TIGHT TO STRUCTURE AND

UTILITIES.

DOOR TAG

ROOM TAG

1 REVISION TAG

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

KEYNOTE TAG

SECTION TAG

WALL TAG

A101

SIM

1 DETAIL TAG

INTERIOR ELEVATION TAG

REFERENCE LEGEND

CARD READER

Room

G3.0

101A

EXTERIOR ELEVATION TAG

?1

A101 1

A101 1

1 Hour Smoke Barrier

0 Hour Smoke Resistant

2 Hour Fire Rated Barrier

1 Hour Fire Rated Barrier

2 Hour Smoke Barrier

EXISTING WALL

DEMOLISHED

WALL

NEW WALL

EXISTING DOOR

DEMOLISHED

DOOR

NEW DOOR

ROOM TAG EXISTING

Room

A101a

SIM

CR

WAVE PLATEWP

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE

BEEN PREPARED USING "AS-DESIGNED" DOCUMENTS PROVIDED BY THE OWNER.

NEITHER THE OWNER NOR THE ARCHITECT WARRANT THESE TO BE "AS-BUILT"

DOCUMENTS, AND ACTUAL CONDITIONS MAY VARY. THE DEMOLITION WORK

INDICATED IS INTENDED TO SHOW THE GENERAL SCOPE OF THE DEMOLITION WORK

AND IN NO WAY RELIEVES THE CONTRACTOR FROM PERFORMING ANY AND ALL

DEMOLITION REQUIRED TO COMPLETE THE NEW WORK.

2. ALL DEMOLITION WORK SHALL BE PERFORMED WITH "DUE CARE AND DILIGENCE"

SO AS TO PREVENT THE ARBITRARY DESTRUCTION OR INTERRUPTION OF

CONCEALED UTILITIES WHICH COULD NOT BE PREDETERMINED UNTIL DEMOLITION

WAS STARTED. ALL SUCH DISCOVERIES OF UTILITIES DURING THE DEMOLITION

PROCESS WHICH ARE IN A LOCATION DIFFERENT FROM FLOOR TO FLOOR, ETC., OR

ARE UNIDENTIFIED, SHALL BE REPORTED TO THE ARCHITECT BEFORE REMOVAL FOR

FINAL DISPOSITION.

3. REMOVE ALL CONSTRUCTION DESIGNATED TO BE REMOVED AND CLEAR TO

RECEIVE NEW WORK AS HEREIN INDICATED.

4. REMOVE PORTIONS OF EXISTING CONSTRUCTION AS DRAWN AND PATCH TO

MATCH ADJACENT CONSTRUCTION.

5. WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE

REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGARS, BRACING,

FOUNDATION, ETC. AFTER REMOVAL, AFFECTED CONSTRUCTION AND SURFACES,

SUCH AS FLOORS ,WALLS, BASES, AND CEILINGS, SHALL BE FINISHED TO MATCH

ADJACENT SURFACES UNLESS OTHERWISE NOTED.

6. NEW WORK SHALL ALIGN WITH AND MATCH EXISTING WORK EXCEPT WHERE

OTHERWISE DIMENSIONED OR DETAILED.

7. ANY EXISTING CONDITIONS WHICH ARE INCONSISTENT WITH CONTRACT DRAWINGS

RELEVANT TO THIS CONTRACT SHALL BE REPORTED TO THE ARCHITECT.

8. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR SURFACES WITH

IMPERFECTIONS OR NOT LEVEL TO TOLERANCES SPECIFIED FOR NEW WORK,

PROVIDE SELFLEVELING UNDERLAYMENT.

9. WHERE DEMOLITION WORK UNCOVERS OR LEAVES OPENINGS IN PARTITIONS OR

INCOMPLETE PARTITIONS, EXTEND, RESTORE, AND/OR CLOSE OPENING IN PARTITION

AS INDICATED AND/OR AS REQUIRED TO MAINTAIN FIRE RATINGS AND SMOKE

BARRIERS. MATCH EXISTING CONSTRUCTION, U.N.O., WITHIN THE LIMITS AND

TOLERANCES FOR MATERIALS AS SPECIFIED OR RECOMMENDED BY THE

MANUFACTURER. REFINISH SURFACES TO ALIGN FLUSH WITH EXISTING.

10. WHERE DEMOLITION WORK OR RELOCATION OF EXISTING ITEMS LEAVES

UNFINISHED SURFACES AND/OR SUBSTRATES, CUT AND PATCH AS REQUIRED TO

RESTORE SUBSTRATE AND/OR FINISH MATERIAL EVEN AND FLUSH WITH ADJOINING

SURFACES. TEXTURE AND REFINISH TO MATCH EXISTING U.N.O.

11. CONTRACTOR SHALL DISPOSE OF ALL ITEMS AND MATERIALS PER

SPECIFICATIONS. OWNER RESERVES THE RIGHT TO SELECT SPECIFIC ITEMS FOR

SALVAGE. THESE ITEMS SHALL BE IDENTIFIED DURING A PRECONSTRUCTION

WALKTHROUGH.

12. FOR FURTHER DEMOLITION INFORMATION REF THE MECHANICAL, ELECTRICAL

AND PLUMBING DRAWINGS.

13. APPLY SELF-LEVELING COMPOUND TO FLOORING WHERE CMU WALLS ARE

DEMOLISHED. GRIND FLOOR PRIOR TO APPLYING SELF-LEVELING COMPOUND IF

REQUIRED TO ALLOW FOR LEVEL FLOOR SURFACE. REFER TO DETAIL 8/S401.

14. PROVIDE TEMPORARY DUST, SIGHT AND SOUND BARRIERS AS REQUIRED BY

OWNER, AND WHEREVER NECESSARY, TO LIMIT THE AMOUNT OF NOISE, DUST,

VISUAL POLLUTION WITHIN AND AROUND THE FACILITY, TO MAINTAIN OCCUPANCY

AND USE OF OCCUPIED AREAS IN THE…