36C24618R0842 CONTRACT ATTACHMENT A - DRAWINGS - FILE 3 - Electrical.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24618R0842-0002004.pdf | ||
| 36C24618R0842-0002002.pdf | ||
| 36C24618R0842-0002000.docx | DOCX document | |
| 36C24618R0842-0002003.pdf | ||
| 36C24618R0842-0002001.pdf | ||
| 36C24618R0842-007.pdf | ||
| 36C24618R0842-006.pdf | ||
| 36C24618R0842-002.pdf | ||
| 36C24618R0842-005.pdf | ||
| 36C24618R0842-008.docx | DOCX document | |
| 36C24618R0842-003.pdf | ||
| 36C24618R0842-001.docx | DOCX document | |
| 36C24618R0842-009.pdf | ||
| 36C24618R0842-000.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
H
M
PS
PS D
V
PTZ
PB
SS
SS
K
KPCR
EXIT
ELC
PP
CR
ES
AL
PB
ML
ERS
BR
BA
NL
EMO
DAS
VFD
W
S
SS
SS
SS S
3050A
ANESTH.
WORK.B
S
SEE LUMINAIRE SCHEDULE number of ballasts in fixture
N/A total exterior wattage specified vs allowed
* total interior wattage specified vs allowed
SEE LUMINAIRE SCHEDULE
SEE LUMINAIRE SCHEDULE
SEE LUMINAIRE SCHEDULE
total wattage per fixture ballast type used in the fixture
PerformancePrescriptive
METHOD OF COMPLIANCE :
ELECTRICAL SYSTEM AND EQUIPMENT
SEE LUMINAIRE SCHEDULE
number of lamps in fixture lamp type required in fixture Lighting schedule
** Lighting shall have a source efficacy of at least 45 lumens per watt.
PerformancePrescriptive
ENERGY CODE
ASHRAE 90.1
506.2.1 MORE EFFICIENT MECHANICAL EQUIPMENT
506.2.2 REDUCED LIGHTING POWER DENSITY
506.2.3 ENERGY RECOVERY VENTILATION SYSTEMS
506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATING
506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY
506.2.6 AUTOMATIC DAY LIGHTING CONTROL SYSTEMS
ELECTRICAL ENERGY CODE SUMMARY
DRAWING TITLE
ELECTRICAL SYMBOLS
RL = EXISTING DEVICE TO BE RELOCATED.
DASHED SYMBOLS INDICATE EXISTING DEVICES.
DOORBELL TRANSFORMER.
DOORBELL BUTTON.
DOORBELL CHIME.
MISCELLANEOUS
WHERE CEILING HEIGHT EXCEEDS 9'-0".
RLD = RELOCATED DEVICE SHOWN IN FINAL LOCATION.
RM = EXISTING DEVICE TO REMAIN.
RV = EXISTING DEVICE TO BE REMOVED.
FLOOR PLAN KEYED NOTES, SEE FLOOR PLAN.
DIMENSION INDICATES HEIGHT, AFF, AT WHICH DEVICE IS TO BE MOUNTED.
ON CENTER.
ABOVE FINISHED FLOOR TO CENTERLINE OF DEVICE.
TELEPHONE TERMINAL BOARD.
EMPTY CONDUIT.
ABBREVIATIONS
AFF
EC
OC
TTB
+60"
NIGHT LIGHTING, 24 HOUR, OPERATION. WIRE AHEAD OF ALL LOCAL SWITCHES.NL
TELEPHONE OUTLET, FLUSH FLOOR MOUNTED.
TELEPHONE OUTLET, WALL MOUNTED 18" AFF TO CENTER OF DEVICE.
SECURITY SYSTEM CLOSED CIRCUIT T.V. CAMERA. SUBSCRIPT INDICATES PAN/TILT/ZOOM CONTROL.
SECURITY SYSTEM DURESS ALARM PUSHBUTTON STATION. SURFACE MOUNTED 42" AFF.
PUBLIC ADDRESS SYSTEM MICROPHONE OUTLET, WALL MOUNTED 18" AFF. COORDINATE TYPE OF
PUBLIC ADDRESS SYSTEM HORN, WALL MOUNTED 7'-6" AFF. UNLESS OTHERWISE INDICATED.
PUBLIC ADDRESS SYSTEM SPEAKER, CEILING MOUNTED.
OUTLET WITH OWNER'S EQUIPMENT.
W = WALL MOUNTED STATION
INTERCOM OUTLET WALL MOUNTED 42" AFF TO CENTER OF DEVICE, WITH DESK MOUNTED STATION
VOICE/DATA OUTLET, WALL MOUNTED 18" AFF TO CENTER OF DEVICE OR SECURITY CAMERA.
MODIFIERS FOR INTERCOM:
S = SUB STATION
M = MASTER STATION
TELEPHONE OUTLET, WALL MOUNTED 48" AFF.
VOICE/DATA OUTLET, WALL MOUNTED 42" AFF, 2" FROM BOTTOM OF OUTLET TO BACKSPLASH.
PROVIDE 3/4"C. FROM OUTLET TO AN ACCESSIBLE SPACE ABOVE THE CORRIDOR LAY-IN CEILING.
OR 6" FROM BOTTOM OF OUTLET TO COUNTERTOP.
TELEPHONE OUTLET WALL MOUNTED 42" AFF, 2" FROM BOTTOM OF OUTLET TO BACKSPLASH,
PROVIDE FLUSH MOUNTED JUNCTION BOX WITH APPROPRIATE COVERPLATE. PROVIDE 1 1/4" EMPTY
CONDUIT WITH NYLON PULL CORD FROM JUNCTION BOX TO ABOVE ACCESSIBLE CEILING FOR
VOICE/DATA WIRING TO PRE-WIRED FURNITURE. COORDINATE EXACT REQUIREMENTS AND LOCATION
MODIFIERS FOR VOICE/DATA & TELEPHONE OUTLETS:
COMMUNICATIONS
VOICE/DATA OUTLET, FLUSH FLOOR MOUNTED.
PUBLIC ADDRESS SYSTEM VOLUME CONTROL SWITCH, WALL MOUNTED 42" AFF.
CONDUIT SLEEVES. SEE PLANS FOR SIZE AND QUANTITY.
FIRE ALARM DUCT MOUNTED SMOKE DETECTOR.
FIRE ALARM TAMPER SWITCH CONNECTION TO SPRINKLER SYSTEM.
FIRE ALARM CENTRAL PROCESSING UNIT/STATUS COMMAND CENTER.
FIRE ALARM AUDIO & VISUAL ALARM SIGNAL. WALL MOUNTED 80" AFF TO BOTTOM OF DEVICE.
FIRE ALARM FLOW SWITCH CONNECTION TO SPRINKLER SYSTEM.
FIRE ALARM SPEAKER MOUNTED IN ELEVATOR CAB.
FIRE ALARM THERMAL DETECTOR.
FIRE ALARM SYSTEM TRANSPONDER.
FIRE ALARM SMOKE DETECTOR.
FIRE ALARM ELEVATOR CONNECTION.
FIRE ALARM MAGNETIC DOOR HOLDER. PROVIDE 120V POWER FROM LIFE-SAFETY BRANCH
FIRE ALARM CEILING MOUNTED REMOTE INDICATING LIGHT. W = WALL MOUNTED 12" BELOW CEILING.
120V CEILING MOUNTED SMOKE DETECTOR.
FIRE ALARM CHIME & VISUAL ALARM SIGNAL, WALL MOUNTED 80" AFF TO BOTTOM OF DEVICE.
FIRE ALARM REMOTE ANNUNCIATOR PANEL. BOTTOM 56" AFF TO TOP OF DEVICE.
FIRE ALARM SPEAKER, CEILING MOUNTED. W = WALL MOUNTED (12" BELOW CEILING OR
FIRE ALARM CONTROL PANEL. MOUNT AT 6'-6" AFF TO TOP.
FIRE ALARM MANUAL PULL STATION, 42" AFF.
CIRCUIT PANEL BOARD PROVIDE 20A/1P CIRCUIT BREAKER. WIRE WITH 2#12+1#12G, 3/4"C.
PROVIDE TRANSFORMER AS REQUIRED BY DOOR HOLDER.
FIRE ALARM
FIRE ALARM CHIME & VISUAL ALARM SIGNAL, CEILING MOUNTED.
FIRE ALARM VISUAL ALARM SIGNAL, WALL MOUNTED 80" AFF TO BOTTOM OF DEVICE.
FIRE ALARM VISUAL ALARM SIGNAL, CEILING MOUNTED.
96" AFF WHERE CEILING HEIGHT EXCEEDS 9'-0").
FLUORESCENT LIGHTING FIXTURE, WALL MOUNTED OR UNDER CABINET, CONNECTED TO NORMAL POWER.
LED, COMPACT FLUORESCENT, OR HID LIGHTING FIXTURE, CEILING OR WALL MOUNTED,
POLE MOUNTED LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE (*).
DRAWINGS. SEE SCHEDULE FOR TYPE (*).
CEILING OR WALL MOUNTED EXIT SIGN. PROVIDE NUMBER OF FACES AND CHEVRONS AS INDICATED ON
EMERGENCY LIGHTING FIXTURE, CEILING-MOUNTED OR WALL-MOUNTED AT 7'-6" AFF UNLESS NOTED
OTHERWISE. CONNECT UNSWITCHED.
LIGHTING
LED, COMPACT FLUORESCENT, OR HID LIGHTING WALLWASH FIXTURE, CEILING MOUNTED.
TRACK LIGHTING FIXTURE. SEE PLANS/SCHEDULE FOR TRACK LENGTH AND NUMBER OF TRACK HEADS.
NURSE CALL PSYCHIATRIC PATIENT STATION, 42" AFF TO CENTER OF DEVICE.
MONITOR OUTLET. COORDINATE EXACT LOCATION WITH OWNER/ARCHITECT.
NARCOTICS CABINET SWITCH CONNECTION.
ELAPSED TIME CLOCK (6'-6" AFF) AND CONTROLS (5'-0" AFF).
DOCTORS' DICTATION OUTLET WALL, MOUNTED 18" AFF, OR 8" ABOVE COUNTER,
NURSE CALL CORRIDOR ZONE LIGHT, CEILING MOUNTED.
NURSE CALL STAFF STATION, 44" AFF TO CENTER OF DEVICE.
NURSE CALL CONNECTION TO DOOR.
OR 2" ABOVE BACKSPLASH.
NURSE CALL DOUBLE PATIENT STATION. SEE PATIENT ROOM ELEVATION FOR MOUNTING HEIGHT, NURSE CALL SINGLE PATIENT STATION. SEE PATIENT ROOM ELEVATION FOR MOUNTING HEIGHT, NURSE CALL SIDECOM INTERFACE MODULE.
NURSE CALL PSYCHIATRIC SPEAKER, CEILING MOUNTED.
NURSE CALL MASTER STATION, DESK MOUNTED.
NURSE CALL KEYED SWITCH STATION, 42" AFF.
NURSE CALL EMERGENCY PSYCHIATRIC PUSHBUTTON, 42" AFF.
NURSE CALL EMERGENCY STATION W/ PULL CORD, 70" AFF.
NURSE CALL EMERGENCY STATION W/ PULL CORD, 30" AFF.
NURSE CALL EMERGENCY STATION W/ PUSH BUTTON WITH 6' CORD, 42" AFF.
NURSE CALL DUTY STATION, 42" AFF TO CENTER OF DEVICE.
NURSE CALL CORRIDOR DOME LIGHT, CEILING MOUNTED.
NURSE CALL CENTRAL EQUIPMENT, MOUNT AT 6'-6" AFF TO TOP.
NURSE CALL CODE BLUE STATION, 42" AFF TO CENTER OF DEVICE.
NURSE CALL ANNUNCIATOR PANEL, WALL RECESSED, MOUNT AT 6'-0" AFF TO TOP.
IF NONE SHOWN MOUNT AT 44" AFF TO CENTER OF DEVICE.
IF NONE SHOWN MOUNT AT 44" AFF TO CENTER OF DEVICE.
NURSE CALL
NARCOTICS ALARM LIGHT.
NURSE CALL SYSTEM LOW VOLTAGE CONTROLLER.
LOW VOLTAGE TV.
EQUIPMENT IDENTIFICATION
HORSEPOWER RATING
MOTOR CONNECTION. SPECIAL VOLTAGES AS SHOWN ON DRAWING.
ENCLOSED CIRCUIT BREAKER. NUMERAL INDICATES TRIP AMPERE RATING.
FUSED SAFETY SWITCH. NUMERAL INDICATES FUSE RATING.
NON-FUSIBLE SAFETY SWITCH. NUMERAL INDICATES AMPERE RATING.
SIZE AND BOTTOM NUMERAL INDICATES NEMA STARTER SIZE.
COMBINATION MOTOR STARTER WITH CIRCUIT BREAKER. TOP NUMERAL INDICATES CIRCUIT BREAKER
MOTOR STARTER. NUMERAL INDICATES NEMA SIZE.
AMPACITY. SEE FEEDER SCHEDULE.
ON RISERS, DESIGNATION DENOTES QUANTITY OF CURRENT CARRYING CONDUCTORS AND FEEDER
WIRING SYSTEM CONCEALED IN OR ABOVE CEILING OR IN WALL.
WIRING SYSTEM BELOW FLOOR OR BELOW GRADE.
ETC. DESIGNATION DENOTES PANEL BOARD, SWITCHBOARD, MOTOR CONTROL CENTER, ETC., AND BRANCH OR FEEDER CIRCUIT HOMERUN TO PANEL BOARD, SWITCHBOARD, MOTOR CONTROL CENTER, WIRING SYSTEM TURNED UP.
WIRING SYSTEM TURNED DOWN.
WIRING SYSTEM EXPOSED.
OVER CURRENT PROTECTION DEVICE NUMBER.
DRY TYPE TRANSFORMER.
NEC REQUIRED GROUND.
EF-1, 10 HP.460V, 3PH
208V, 3PH
120V, 1PH
MOTOR RATED SWITCH.
CONNECTION TO WALL MOUNTED FILM ILLUMINATOR. PROVIDE RECEPTACLE IN FLUSH OUTLET BOX AT
LOWER RIGHT HAND CORNER OF UNIT IF SURFACE MOUNTED. HARD WIRE IF RECESSED.
JUNCTION BOX AND CONNECTION TO EQUIPMENT OR TERMINAL STRIPS.
CEILING FAN 120V. MANUFACTURER (HUNTER#21252 GREEN FINISH W/ INTEGRATED 240W LIGHT FIXTURE)
CONNECTION TO FAN COIL UNIT. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR.
CONNECTION TO EXHAUST FAN. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR.
PANELBOARD SURFACE MOUNTED.
REMOTE ALARM PANEL FOR ISOLATED POWER PANEL BOARD WALL MOUNTED AT 5'-0" AFF.
GENERATOR REMOTE ALARM ANNUNCIATOR. WALL MOUNTED AT 5'-0" AFF.
BLANK = NORMAL BRANCH
U = UNGROUNDED (ISOLATION) PANEL
Q = EQUIPMENT BRANCH
C = CRITICAL BRANCH
L = LIFE SAFETY BRANCH
M = MOTOR CONTROL CENTER
L = 120/208 VOLT
H = 277/480 VOLT
PANELBOARD FLUSH MOUNTED.
1,2,3 = FLOOR
A,B,C = LOCATION
PANELBOARD NAMING CONVENTION
JUNCTION OR PULL BOX. W = WEATHERPROOF.
CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE.
HARDWIRE CONNECTION FROM FLUSH MOUNTED JUNCTION BOX WITH APPROPRIATE COVERPLATE AND 3/4" LIQUID TIGHT FLEXIBLE METALLIC WHIP TO PRE-WIRED FURNITURE. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH EQUIPMENT SUPPLIER/INSTALLER. EIGHT(8) WIRE SYSTEM PROVIDES FOUR(4) CIRCUITS.
POWER
SURFACE MOUNTED MULTIOUTLET ASSEMBLY. 46" AFF OR 8" ABOVE COUNTER
TV = TELEVISION, SEE DETAIL.
G = GROUND FAULT CIRCUIT INTERRUPTER.
EWC = ELECTRIC WATER COOLER POWER CONNECTION, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER
P = PEDESTAL
WP = WEATHERPROOF "IN-USE" COVER, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER DEVICE.
DUPLEX RECEPTACLE, MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE
OR 2" ABOVE BACKSPLASH. SHADED AREA INDICATES RECEPTACLE.
DUPLEX RECEPTACLE OUTLET. FLUSH FLOOR MOUNTED.
SIMPLEX RECEPTACLE MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE
TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 42" AFF TO CENTER OF OUTLET
OR 2" FROM BOTTOM OF OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES
OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES CONNECTED TO THE EMERGENCY
DUPLEX RECEPTACLE, MOUNTED 42" AFF TO CENTER OF OUTLET OR 2" FROM BOTTOM OF
TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 18" AFF TO CENTER OF DEVICE. SLASH
DUPLEX RECEPTACLE OUTLET. CEILING MOUNTED. SLASH INDICATES
SPECIAL RECEPTACLE OUTLET. NEMA CONFIGURATION AS INDICATED.
MODIFIERS FOR RECEPTACLES:
SPECIAL RECEPTACLE OUTLET. NEMA CONFIGURATION AS INDICATED.
LH2A-1
CH2A
EQUIPMENT CONNECTION DESIGNATION, SEE SCHEDULE FOR DETAILS.
RATING AND BOTTOM NUMERAL INDICATES NEMA STARTER SIZE.
COMBINATION MOTOR STARTER WITH FUSED SWITCH. TOP NUMERAL INDICATES FUSETRON AMPERE
LIGHTNING PROTECTION SYSTEM GROUND ROD.
75KVA
LIGHTNING PROTECTION SYSTEM AIR TERMINAL.
TR = TAMPER RESISTANT
3 = THREE WAY
MODIFIERS FOR SWITCHES:
SINGLE POLE SWITCH.
THREE SINGLE POLE SWITCHES IN A 3-GANG BOX.
PHOTO ELECTRIC CELL MOUNTED ON CONDUIT STUBBED 6" ABOVE ROOF, FACING NORTH.
SWITCHES
TWO SINGLE POLE SWITCHES IN A 2-GANG BOX.
PROVIDE DIVIDER FOR DIFFERENT VOLTAGES OR BRANCHES.
4 = FOUR WAY
D = DIMMER
DT = DOUBLE THROW
LV = LOW VOLTAGE
PROVIDE DIVIDER(S) FOR DIFFERENT VOLTAGES OR BRANCHES.
OS = OCCUPANCY SENSOR
TIME CLOCK. PROVIDE POWER CIRCUIT AND 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE.
a,b,c = MULTIPLE SWITCH LEGS
T = TIMER
INDICATED.
INDICATED. SLASH INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.
INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.
CONNECTED TO NORMAL POWER. SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTUAL RCP FOR EXACT
LUMINAIRE, 2x4, CEILING MOUNTED, CONNECTED TO THE NORMAL POWER SYSTEM (UNLESS OTHERWISE NOTED). SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT LOCATION/CEILING TYPE.
LOCATION AND CEILING TYPE. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.
SEE SCHEDULE FOR TYPE (*).
SEE SCHEDULE FOR TYPE (*).
REMOTE EMERGENCY EGRESS TWIN-LAMP UNIT.
HALF-SHADED INDICATES CONNECTED TO LIFE SAFETY BRANCH.
UNLESS NOTED OTHERWISE.
WITH EQUIPMENT SUPPLIER/INSTALLER.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. SEE SCHEDULE FOR TYPE (*).
NURSE CALL PILLOW SPEAKER.
NURSE CALL SINGLE CALL CORD.
NURSE CALL HEADEND EQUIPMENT.
FIRE ALARM SPEAKER AND VISUAL ALARM SIGNAL, CEILING MOUNTED.
HEADWALL. SEE PLAN FOR NUMBER.HW#
POWER COLUMN. SEE PLAN FOR NUMBER.PC#
POWER SYSTEM.
CONNECTED TO THE EMERGENCY POWER SYSTEM.
FLUORESCENT STRIP LUMINAIRE. CEILING MOUNTED OR SUSPENDED 8'-0" AFF TO BOTTOM OF LUMINAIRE, CONNECTED TO NORMAL POWER. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.
HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY
GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
CARD READER. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.
ELECTRIC STRIKE. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.
WALL MOUNTED LOCAL ALARM BUZZER, 85dBA.
DURESS ALARM BUTTON RECESSED IN COUNTER.
MAGNETIC LOCK FOR DOOR.
PUBLIC ADDRESS SYSTEM SPEAKER, CEILING MOUNTED.
REMOTE LINE ISOLATION MONITOR.
CABLE TV OUTLET, MOUNTED ADJACENT TO TV RECEPTACLE, UNLESS NOTED OTHERWISE.
PUSHPAD. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.
VARIABLE SPEED DRIVEVSD
FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED.
WIRELESS TELEMETRY ANTENNA
WIRELESS TELEMETRY DEVICE
EXPEDITER BUTTON PANEL
EXAM LIGHT CONTROLLER
EMERGENCY EGRESS PUSH BUTTON
KEY PAD CARD READER
FIRE ALARM SPEAKER AND VISUAL ALARM SIGNAL, WALL MOUNTED.
EMERGENCY RELEASE SWITCH. PROVIDE TAMPER RESISTANT COVER WITH A SOUNDING HORN.
RP = EXISTING DEVICE TO BE REPLACED WITH NEW DEVICE.
PNEUMATIC TUBE STATIONPTS
BUTTON RELEASE.
BADGE ACCESS.
NURSE LOCATOR.
EMERGENCY MANUAL OVERRIDE.
DEVICE. INSTALL DEVICE SO IT IS CONCEALED BEHIND ENCLOSURE, COORDINATE WITH PLUMBING.
SHOWN TO CLARIFY THAT DEVICES/LUMINAIRES ON THE SAME CIRCUIT ARE CONTROLLED SEPARATELY.
POLE MOUNTED LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE (*).
SYMBOL LOCATION LEADER
POWER CONNECTION TO FIRE DAMPER. SEE DETAIL.
POWER AND FIRE ALARM CONNECTION TO SMOKE DAMPER OR FIRE/SMOKE DAMPER. SEE DETAIL.
NURSE CALL CORRIDOR DOME LIGHT, WALL MOUNT ABOVE DOOR AT 4" FROM THE TOP OF THE
DOOR FRAME TO THE BOTTOM OF THE DEVICE.
NURSE CALL CORRIDOR ZONE LIGHT, WALL MOUNT ABOVE DOOR AT 4" FROM THE TOP OF THE
DOOR FRAME TO THE BOTTOM OF THE DEVICE.
ROOM TAG
ELAPSED TIME CONTROL. MOUNT 48" AFF
BOOM LIGHT CONTROLLER
PUSH BUTTON
CONNECT LIFE SAFETY CIRCUIT TO MEDICAL GAS ALARM PANEL. 120V, 20A
WIRELESS ACCESS POINT
CODE BLUE RECEIVER
FIRE ALARM CONNECTION TO KNOX BOX.
PROVIDE DISCONNECT SWITCH AND CONNECTION TO MOTOR OPERATED DOOR. COORDINATE WITH
HARDWARE VENDOR.
INTERCOM STATION WITH BUILT IN CAMERA.
INTERCOM STATION WITH BUILT VIDEO MONITOR.
PROVIDE CONNECTION TO OWNER FURNISHED ELAPSED TIME CLOCK. MOUNT 84" AFF.
RV RM
RM
DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR. PROVIDE ONE POWER PACK FOR EACH SENSOR. COORDINATE WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.
CARBON MONOXIDE DETECTOR. CEILING MOUNT.
FIRE ALARM CONNECTION TO KNOX BOX.
FIRE ALARM CONNECTION TO AUTOMATIC DOOR.
( NOTE: SYMBOLS WITHIN THIS SCHEDULE ARE REPRESENTATIVE OF THOSE TYPICALLY FOUND ON THE DRAWINGS. ALL SYMBOLS MAY NOT APPEAR ON THIS SET OF DRAWINGS. )
GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE OUTLET. SLASH INDICATES
CONNECTED TO THE EMERGENCY POWER SYSTEM.
TAMPER RESISTENT DUPLEX RECEPTACLE OUTLET. SLASH INDICATES
CONNECTED TO THE EMERGENCY POWER SYSTEM.
LUMINAIRE, 2X2, CEILING MOUNTED, CONNECTED TO THE NORMAL POWER SYSTEM (UNLESS OTHERWISE NOTED). SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT LOCATION/CEILING TYPE.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
M
C
C
30CB
DB
DT
E
F
H
GA
J
J
M
LIM
P
PE
RA
T
TC
CB
FAC
CO
AD
CL
F
CL
DD
EC
ES
FACP
FARA
FATR
FD
FS
FS
H
FSD
KB
OS
L
HL
LD
L
SD
RL
SL
SD
TD
TS
SL
BL
D
DR
ET
ETC
IC
IM
M
MGA
MOD
NA
NA
NC
NC
NBO
NCL
NB
NCL
NCS
NEC
NEB
ND
NEC
NEP
NHE
NKS
NLV
NMS
NZL
NZL
NPP
NP1
NP2
NS
PS1
SCC
TV
WA
ET
G
TR TR
G
S
ELECTRICAL - SYMBOL SCHEDULE, NOTES AND DRAWING INDEX
ELECTRICAL - DETAILS AND NOTES
ELECTRICAL - LUMINAIRE SCHEDULE AND DETAILS
ELECTRICAL - LIGHTNING PROTECTION DETAILS
ELECTRICAL - VENDOR DETAILS
ELECTRICAL - FOURTH FLOOR - DEMOLITION PLAN
ELECTRICAL - FIFTH FLOOR - DEMOLITION PLAN
ELECTRICAL - FOURTH FLOOR - NEW WORK - LIGHTING - AREA A
ELECTRICAL - FOURTH FLOOR - NEW WORK - LIGHTING - AREA B
ELECTRICAL - FOURTH FLOOR - NEW WORK - LIGHTING - AREA C
ELECTRICAL - FOURTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA A
ELECTRICAL - FOURTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA B
ELECTRICAL - FOURTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA C
ELECTRICAL - FIFTH FLOOR - NEW WORK - LIGHTING - AREA A
ELECTRICAL - FIFTH FLOOR - NEW WORK - LIGHTING - AREA B
ELECTRICAL - FIFTH FLOOR - NEW WORK - LIGHTING - AREA C
ELECTRICAL - FIFTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA A
ELECTRICAL - FIFTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA B
ELECTRICAL - FIFTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA C
ELECTRICAL - ROOF PLAN - NEW WORK - POWER
E001 E002 E003 E004 E005
ED400
ED500
E400A E400B E400C E401A E401B E401C E500A E500B E500C E501A E501B E501C E600
CONNECTION TO PRE-FABRICATED HEADWALL UNIT. WITH NORMAL AND CRITICAL POWER
CIRCUITS AND COMMUNICATION SERVICES.
TWO SINGLE POLE SWITCHES IN A 2-GANG BOX. EITHER SWITCH INBOARD AND OUTBOARD LAMPS
SEPARATELY OR STEP-DIM BOTH LAMPS TO 50%.
ELECTRICAL - ROOF - DEMOLITION PLANED600
ELECTRICAL - PANEL SCHEDULESE010
ED300 ELECTRICAL - THIRD FLOOR - DEMOLITION PLAN
E100 ELECTRICAL - GROUND FLOOR - NEW WORK - POWER
ELECTRICAL - THIRD FLOOR - NEW WORK - LIGHTING - AREA CE300C
ELECTRICAL - THIRD FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA CE301C
ELECTRICAL - PANEL SCHEDULESE011
ELECTRICAL - DETAILSE006
ELECTRICAL - POWER RISER DIAGRAME007
FIRE ALARM ISOLATION MODULE.ISO
DURESS ALARM SYSTEM INTRFACE CONNECTIONS.
(1 VOICE/1 DATA DENOTES QUANTITY OF VOICE/DATA OUTLETS)
* No new lighting load added.
VARIABLE FREQUENCY DRIVE.
ELECTRICAL - SITE PLANE020
CONNECTED TO THE EMERGENCY POWER SYSTEM.
VOICE/DATA OUTLET, CEILING MOUNTED.
GENERAL NOTES
A. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE SCALE,
WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.
B. SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE OWNERS'
REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK. THIS TIME
LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL BE AT THE
OWNERS' DISCRETION.
C. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.
D. ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING EQUIPMENT THAT IS TO
REMAIN AS REQUIRED IN ORDER TO FACILITATE INSTALLATION OF NEW WORK.
E. ELECTRICAL CONTRACTOR IS NOT PERMITTED TO ROUTE WIRING CONNECTED TO THE
LIFE SAFETY OR CRITICAL BRANCH SOURCES OF POWER IN FLEXIBLE METAL
RACEWAYS OR METAL SHEATHED CABLE ASSEMBLIES, WITH THE EXCEPTIONS OF THE
EXEMPTIONS LISTED IN NEC 517.30.C.3.
F. ELECTRICAL CONTRACTORS SHALL PROVIDE SEPARATE RACEWAY, JUNCTION BOXES
OR CABINETS THAT ROUTE LIFE SAFETY AND/OR CRITICAL BRANCH CIRCUITS WIRING
FROM ALL WIRING AND EQUIPMENT CONNECTED TO OTHER BRANCHES OF POWER.
G. ALL FIXED ELECTRICAL EQUIPMENT FURNISHED BY ELECTRICAL CONTRACTOR SHALL
BE LISTED AND LABELED BY AN APPROVED NORTH CAROLINA TESTING AGENCY.
FACTORY ASSEMBLED LISTED COMPONENTS SHALL BE LISTED AND LABELED AS AN
ASSEMBLY. ANY ELECTRICAL EQUIPMENT NOT LISTED OR LABELED MUST BE
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION AND HAVE A THIRD
PARTY TESTING LABEL OR SHALL BE REPLACED WITH EQUIPMENT THAT IS UL
LABELED/LISTED AT THE CONTRACTOR'S EXPENSE.
H. CONTRACTOR SHALL COORDINATE WITH THE FACILITY'S INFECTION CONTROL
OFFICER TO VERIFY THAT APPROPRIATE SAFEGUARDS ARE BEING TAKEN TO PROTECT
WORKERS INVOLVED IN DEMOLITION ACTIVITIES.
I. CONTRACTOR SHALL COORDINATE WITH FACILITY'S INFECTION CONTROL OFFICER TO
VERIFY THAT APPROPRIATE PRECAUTIONS ARE BEING TAKEN TO PROTECT FACILITY
STAFF AND PATIENTS DURING THE CONSTRUCTION ACTIVITIES.
J. ASBESTOS CONTAINING MATERIALS (IF PRESENT) WILL BE IDENTIFIED BY THE OWNER
AND WILL BE REMOVED FROM AHU'S, PIPING INSULATION, DUCT INSULATION, ETC. (IF
REQUIRED) PRIOR TO CONTRACTOR BEGINNING ANY WORK ON THE SITE. COORDINATE
WITH OWNER.
K. UNLESS NOTED OTHERWISE, ELECTRICAL CONTRACTOR SHALL INSTALL ALL
RACEWAY, BOXES, AND CABLES. ALL MEDICAL EQUIPMENT CABLES, UNLESS
OTHERWISE NOTED, SHALL BE PROVIDED BY MEDICAL EQUIPMENT VENDOR.
L. ALL ELECTRICAL WORK MUST BE COMPLETED IN PHASES, AS ESTABLISHED IN
"GENERAL CONDITIONS".
Q. BRANCH CIRCUIT WIRE SIZING WILL BE IN ACCORD WITH THE FOLLOWING TABLES:
VOLTS
120/208
DISTANCE
0' - 50'
HOME RUN
#12
REMAINDER
OF CIRCUIT
50' - 100' 100' - 150'
#10 #8
#12 #12 #10
VOLTS
277/480
DISTANCE
0' - 125'
HOME RUN
#12
REMAINDER
OF CIRCUIT
125' - 220' 220' - 330'
#10 #8
#12 #12 #10
P. ELECTRICAL CONTRACTOR SHALL USE MULTI-POLE BREAKERS FOR ALL SHARED
NEUTRALS OR PROVIDE SEPARATE NEUTRALS FOR EACH BRANCH CIRCUIT. ADJUST
PANEL SCHEDULES ACCORDINGLY TO MEET NEC 210.4.
O. CONDUCTORS SHALL BE COPPER, RATED AT NOT LESS THAN 600 VOLTS.
MINIMUM SIZE SHALL BE NO. 12 AWG UNLESS OTHERWISE NOTED ON THE DRAWINGS.
ALL WIRE #8 AWG AND LARGER SHALL BE STRANDED. #10 THRU #12 AWG
CONDUCTORS SHALL BE SOLID. ALL INSULATION TYPES SHALL BE THWN OR THHN.
N. A MAXIMUM OF THREE 20A, 1 POLE BRANCH CIRCUITS MAY BE COMBINED IN A
COMMON HOMERUN SHARING A COMMON NEUTRAL OR WITH SEPARATE NEUTRALS,
FOR A TOTAL OF SIX CURRENT - CARRYING CONDUCTORS. ALL BRANCH CIRCUITS
LARGER THAN 20A SHALL BE SEPARATELY HOMERUN TO PANEL TO MEET NEC 200.4.
M. PER NEC REQUIREMENTS, EQUIPMENT GROUNDING TERMINAL BUSES OF THE
NORMAL AND ESSENTIAL BRANCH-CIRCUIT PANELBOARDS SERVING THE SAME
INDIVIDUAL PATIENT CARE VICINITY SHALL BE CONNECTED TOGETHER WITH AN
INSULATED CONTINUOUS COPPER CONDUCTOR NOT SMALLER THAN 10 AWG.
ELECTRICAL - VENDOR DRAWINGSE008
ELECTRICAL - VENDOR DRAWINGSE009
ELECTRICAL - VENDOR DRAWINGSE012
ELECTRICAL - VENDOR DRAWINGSE013
ELECTRICAL - VENDOR DRAWINGSE014
DRAWING INDEX
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000 Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road Suite 500 Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
/1
9/
:2 3:
P
M M
:\R ev it
\3
C E
C en tra l M od el .rv t
E001
ELECTRICAL - SYMBOL
SCHEDULE, NOTES AND
DRAWING INDEX
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
MMF
CLH
Salisbury, NC
100% FINAL DESIGN
11/10/16
Item Date Description
1 05/08/17 Revision 1 2 10/31/17 Revision 2 - Hybrid 2
C
H
M
PS
PS D
V
PTZ
PB
SS
SS
K
KPCR
EXIT
ELC
PP
CR
ES
AL
PB
ML
ERS
BR
BA
NL
EMO
DAS
VFD
W
S
SS
SS
SS S
3050A
ANESTH.
WORK.B
S
SEE LUMINAIRE SCHEDULE number of ballasts in fixture
N/A total exterior wattage specified vs allowed
* total interior wattage specified vs allowed
SEE LUMINAIRE SCHEDULE
SEE LUMINAIRE SCHEDULE
SEE LUMINAIRE SCHEDULE
total wattage per fixture ballast type used in the fixture
PerformancePrescriptive
METHOD OF COMPLIANCE :
ELECTRICAL SYSTEM AND EQUIPMENT
SEE LUMINAIRE SCHEDULE
number of lamps in fixture lamp type required in fixture Lighting schedule
** Lighting shall have a source efficacy of at least 45 lumens per watt.
PerformancePrescriptive
ENERGY CODE
ASHRAE 90.1
506.2.1 MORE EFFICIENT MECHANICAL EQUIPMENT
506.2.2 REDUCED LIGHTING POWER DENSITY
506.2.3 ENERGY RECOVERY VENTILATION SYSTEMS
506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATING
506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY
506.2.6 AUTOMATIC DAY LIGHTING CONTROL SYSTEMS
ELECTRICAL ENERGY CODE SUMMARY
DRAWING TITLE
ELECTRICAL SYMBOLS
RL = EXISTING DEVICE TO BE RELOCATED.
DASHED SYMBOLS INDICATE EXISTING DEVICES.
DOORBELL TRANSFORMER.
DOORBELL BUTTON.
DOORBELL CHIME.
MISCELLANEOUS
WHERE CEILING HEIGHT EXCEEDS 9'-0".
RLD = RELOCATED DEVICE SHOWN IN FINAL LOCATION.
RM = EXISTING DEVICE TO REMAIN.
RV = EXISTING DEVICE TO BE REMOVED.
FLOOR PLAN KEYED NOTES, SEE FLOOR PLAN.
DIMENSION INDICATES HEIGHT, AFF, AT WHICH DEVICE IS TO BE MOUNTED.
ON CENTER.
ABOVE FINISHED FLOOR TO CENTERLINE OF DEVICE.
TELEPHONE TERMINAL BOARD.
EMPTY CONDUIT.
ABBREVIATIONS
AFF
EC
OC
TTB
+60"
NIGHT LIGHTING, 24 HOUR, OPERATION. WIRE AHEAD OF ALL LOCAL SWITCHES.NL
TELEPHONE OUTLET, FLUSH FLOOR MOUNTED.
TELEPHONE OUTLET, WALL MOUNTED 18" AFF TO CENTER OF DEVICE.
SECURITY SYSTEM CLOSED CIRCUIT T.V. CAMERA. SUBSCRIPT INDICATES PAN/TILT/ZOOM CONTROL.
SECURITY SYSTEM DURESS ALARM PUSHBUTTON STATION. SURFACE MOUNTED 42" AFF.
PUBLIC ADDRESS SYSTEM MICROPHONE OUTLET, WALL MOUNTED 18" AFF. COORDINATE TYPE OF
PUBLIC ADDRESS SYSTEM HORN, WALL MOUNTED 7'-6" AFF. UNLESS OTHERWISE INDICATED.
PUBLIC ADDRESS SYSTEM SPEAKER, CEILING MOUNTED.
OUTLET WITH OWNER'S EQUIPMENT.
W = WALL MOUNTED STATION
INTERCOM OUTLET WALL MOUNTED 42" AFF TO CENTER OF DEVICE, WITH DESK MOUNTED STATION
VOICE/DATA OUTLET, WALL MOUNTED 18" AFF TO CENTER OF DEVICE OR SECURITY CAMERA.
MODIFIERS FOR INTERCOM:
S = SUB STATION
M = MASTER STATION
TELEPHONE OUTLET, WALL MOUNTED 48" AFF.
VOICE/DATA OUTLET, WALL MOUNTED 42" AFF, 2" FROM BOTTOM OF OUTLET TO BACKSPLASH.
PROVIDE 3/4"C. FROM OUTLET TO AN ACCESSIBLE SPACE ABOVE THE CORRIDOR LAY-IN CEILING.
OR 6" FROM BOTTOM OF OUTLET TO COUNTERTOP.
TELEPHONE OUTLET WALL MOUNTED 42" AFF, 2" FROM BOTTOM OF OUTLET TO BACKSPLASH,
PROVIDE FLUSH MOUNTED JUNCTION BOX WITH APPROPRIATE COVERPLATE. PROVIDE 1 1/4" EMPTY
CONDUIT WITH NYLON PULL CORD FROM JUNCTION BOX TO ABOVE ACCESSIBLE CEILING FOR
VOICE/DATA WIRING TO PRE-WIRED FURNITURE. COORDINATE EXACT REQUIREMENTS AND LOCATION
MODIFIERS FOR VOICE/DATA & TELEPHONE OUTLETS:
COMMUNICATIONS
VOICE/DATA OUTLET, FLUSH FLOOR MOUNTED.
PUBLIC ADDRESS SYSTEM VOLUME CONTROL SWITCH, WALL MOUNTED 42" AFF.
CONDUIT SLEEVES. SEE PLANS FOR SIZE AND QUANTITY.
FIRE ALARM DUCT MOUNTED SMOKE DETECTOR.
FIRE ALARM TAMPER SWITCH CONNECTION TO SPRINKLER SYSTEM.
FIRE ALARM CENTRAL PROCESSING UNIT/STATUS COMMAND CENTER.
FIRE ALARM AUDIO & VISUAL ALARM SIGNAL. WALL MOUNTED 80" AFF TO BOTTOM OF DEVICE.
FIRE ALARM FLOW SWITCH CONNECTION TO SPRINKLER SYSTEM.
FIRE ALARM SPEAKER MOUNTED IN ELEVATOR CAB.
FIRE ALARM THERMAL DETECTOR.
FIRE ALARM SYSTEM TRANSPONDER.
FIRE ALARM SMOKE DETECTOR.
FIRE ALARM ELEVATOR CONNECTION.
FIRE ALARM MAGNETIC DOOR HOLDER. PROVIDE 120V POWER FROM LIFE-SAFETY BRANCH
FIRE ALARM CEILING MOUNTED REMOTE INDICATING LIGHT. W = WALL MOUNTED 12" BELOW CEILING.
120V CEILING MOUNTED SMOKE DETECTOR.
FIRE ALARM CHIME & VISUAL ALARM SIGNAL, WALL MOUNTED 80" AFF TO BOTTOM OF DEVICE.
FIRE ALARM REMOTE ANNUNCIATOR PANEL. BOTTOM 56" AFF TO TOP OF DEVICE.
FIRE ALARM SPEAKER, CEILING MOUNTED. W = WALL MOUNTED (12" BELOW CEILING OR
FIRE ALARM CONTROL PANEL. MOUNT AT 6'-6" AFF TO TOP.
FIRE ALARM MANUAL PULL STATION, 42" AFF.
CIRCUIT PANEL BOARD PROVIDE 20A/1P CIRCUIT BREAKER. WIRE WITH 2#12+1#12G, 3/4"C.
PROVIDE TRANSFORMER AS REQUIRED BY DOOR HOLDER.
FIRE ALARM
FIRE ALARM CHIME & VISUAL ALARM SIGNAL, CEILING MOUNTED.
FIRE ALARM VISUAL ALARM SIGNAL, WALL MOUNTED 80" AFF TO BOTTOM OF DEVICE.
FIRE ALARM VISUAL ALARM SIGNAL, CEILING MOUNTED.
96" AFF WHERE CEILING HEIGHT EXCEEDS 9'-0").
FLUORESCENT LIGHTING FIXTURE, WALL MOUNTED OR UNDER CABINET, CONNECTED TO NORMAL POWER.
LED, COMPACT FLUORESCENT, OR HID LIGHTING FIXTURE, CEILING OR WALL MOUNTED,
POLE MOUNTED LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE (*).
DRAWINGS. SEE SCHEDULE FOR TYPE (*).
CEILING OR WALL MOUNTED EXIT SIGN. PROVIDE NUMBER OF FACES AND CHEVRONS AS INDICATED ON
EMERGENCY LIGHTING FIXTURE, CEILING-MOUNTED OR WALL-MOUNTED AT 7'-6" AFF UNLESS NOTED
OTHERWISE. CONNECT UNSWITCHED.
LIGHTING
LED, COMPACT FLUORESCENT, OR HID LIGHTING WALLWASH FIXTURE, CEILING MOUNTED.
TRACK LIGHTING FIXTURE. SEE PLANS/SCHEDULE FOR TRACK LENGTH AND NUMBER OF TRACK HEADS.
NURSE CALL PSYCHIATRIC PATIENT STATION, 42" AFF TO CENTER OF DEVICE.
MONITOR OUTLET. COORDINATE EXACT LOCATION WITH OWNER/ARCHITECT.
NARCOTICS CABINET SWITCH CONNECTION.
ELAPSED TIME CLOCK (6'-6" AFF) AND CONTROLS (5'-0" AFF).
DOCTORS' DICTATION OUTLET WALL, MOUNTED 18" AFF, OR 8" ABOVE COUNTER,
NURSE CALL CORRIDOR ZONE LIGHT, CEILING MOUNTED.
NURSE CALL STAFF STATION, 44" AFF TO CENTER OF DEVICE.
NURSE CALL CONNECTION TO DOOR.
OR 2" ABOVE BACKSPLASH.
NURSE CALL DOUBLE PATIENT STATION. SEE PATIENT ROOM ELEVATION FOR MOUNTING HEIGHT, NURSE CALL SINGLE PATIENT STATION. SEE PATIENT ROOM ELEVATION FOR MOUNTING HEIGHT, NURSE CALL SIDECOM INTERFACE MODULE.
NURSE CALL PSYCHIATRIC SPEAKER, CEILING MOUNTED.
NURSE CALL MASTER STATION, DESK MOUNTED.
NURSE CALL KEYED SWITCH STATION, 42" AFF.
NURSE CALL EMERGENCY PSYCHIATRIC PUSHBUTTON, 42" AFF.
NURSE CALL EMERGENCY STATION W/ PULL CORD, 70" AFF.
NURSE CALL EMERGENCY STATION W/ PULL CORD, 30" AFF.
NURSE CALL EMERGENCY STATION W/ PUSH BUTTON WITH 6' CORD, 42" AFF.
NURSE CALL DUTY STATION, 42" AFF TO CENTER OF DEVICE.
NURSE CALL CORRIDOR DOME LIGHT, CEILING MOUNTED.
NURSE CALL CENTRAL EQUIPMENT, MOUNT AT 6'-6" AFF TO TOP.
NURSE CALL CODE BLUE STATION, 42" AFF TO CENTER OF DEVICE.
NURSE CALL ANNUNCIATOR PANEL, WALL RECESSED, MOUNT AT 6'-0" AFF TO TOP.
IF NONE SHOWN MOUNT AT 44" AFF TO CENTER OF DEVICE.
IF NONE SHOWN MOUNT AT 44" AFF TO CENTER OF DEVICE.
NURSE CALL
NARCOTICS ALARM LIGHT.
NURSE CALL SYSTEM LOW VOLTAGE CONTROLLER.
LOW VOLTAGE TV.
EQUIPMENT IDENTIFICATION
HORSEPOWER RATING
MOTOR CONNECTION. SPECIAL VOLTAGES AS SHOWN ON DRAWING.
ENCLOSED CIRCUIT BREAKER. NUMERAL INDICATES TRIP AMPERE RATING.
FUSED SAFETY SWITCH. NUMERAL INDICATES FUSE RATING.
NON-FUSIBLE SAFETY SWITCH. NUMERAL INDICATES AMPERE RATING.
SIZE AND BOTTOM NUMERAL INDICATES NEMA STARTER SIZE.
COMBINATION MOTOR STARTER WITH CIRCUIT BREAKER. TOP NUMERAL INDICATES CIRCUIT BREAKER
MOTOR STARTER. NUMERAL INDICATES NEMA SIZE.
AMPACITY. SEE FEEDER SCHEDULE.
ON RISERS, DESIGNATION DENOTES QUANTITY OF CURRENT CARRYING CONDUCTORS AND FEEDER
WIRING SYSTEM CONCEALED IN OR ABOVE CEILING OR IN WALL.
WIRING SYSTEM BELOW FLOOR OR BELOW GRADE.
ETC. DESIGNATION DENOTES PANEL BOARD, SWITCHBOARD, MOTOR CONTROL CENTER, ETC., AND BRANCH OR FEEDER CIRCUIT HOMERUN TO PANEL BOARD, SWITCHBOARD, MOTOR CONTROL CENTER, WIRING SYSTEM TURNED UP.
WIRING SYSTEM TURNED DOWN.
WIRING SYSTEM EXPOSED.
OVER CURRENT PROTECTION DEVICE NUMBER.
DRY TYPE TRANSFORMER.
NEC REQUIRED GROUND.
EF-1, 10 HP.460V, 3PH
208V, 3PH
120V, 1PH
MOTOR RATED SWITCH.
CONNECTION TO WALL MOUNTED FILM ILLUMINATOR. PROVIDE RECEPTACLE IN FLUSH OUTLET BOX AT
LOWER RIGHT HAND CORNER OF UNIT IF SURFACE MOUNTED. HARD WIRE IF RECESSED.
JUNCTION BOX AND CONNECTION TO EQUIPMENT OR TERMINAL STRIPS.
CEILING FAN 120V. MANUFACTURER (HUNTER#21252 GREEN FINISH W/ INTEGRATED 240W LIGHT FIXTURE)
CONNECTION TO FAN COIL UNIT. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR.
CONNECTION TO EXHAUST FAN. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR.
PANELBOARD SURFACE MOUNTED.
REMOTE ALARM PANEL FOR ISOLATED POWER PANEL BOARD WALL MOUNTED AT 5'-0" AFF.
GENERATOR REMOTE ALARM ANNUNCIATOR. WALL MOUNTED AT 5'-0" AFF.
BLANK = NORMAL BRANCH
U = UNGROUNDED (ISOLATION) PANEL
Q = EQUIPMENT BRANCH
C = CRITICAL BRANCH
L = LIFE SAFETY BRANCH
M = MOTOR CONTROL CENTER
L = 120/208 VOLT
H = 277/480 VOLT
PANELBOARD FLUSH MOUNTED.
1,2,3 = FLOOR
A,B,C = LOCATION
PANELBOARD NAMING CONVENTION
JUNCTION OR PULL BOX. W = WEATHERPROOF.
CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE.
HARDWIRE CONNECTION FROM FLUSH MOUNTED JUNCTION BOX WITH APPROPRIATE COVERPLATE AND 3/4" LIQUID TIGHT FLEXIBLE METALLIC WHIP TO PRE-WIRED FURNITURE. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH EQUIPMENT SUPPLIER/INSTALLER. EIGHT(8) WIRE SYSTEM PROVIDES FOUR(4) CIRCUITS.
POWER
SURFACE MOUNTED MULTIOUTLET ASSEMBLY. 46" AFF OR 8" ABOVE COUNTER
TV = TELEVISION, SEE DETAIL.
G = GROUND FAULT CIRCUIT INTERRUPTER.
EWC = ELECTRIC WATER COOLER POWER CONNECTION, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER
P = PEDESTAL
WP = WEATHERPROOF "IN-USE" COVER, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER DEVICE.
DUPLEX RECEPTACLE, MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE
OR 2" ABOVE BACKSPLASH. SHADED AREA INDICATES RECEPTACLE.
DUPLEX RECEPTACLE OUTLET. FLUSH FLOOR MOUNTED.
SIMPLEX RECEPTACLE MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE
TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 42" AFF TO CENTER OF OUTLET
OR 2" FROM BOTTOM OF OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES
OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES CONNECTED TO THE EMERGENCY
DUPLEX RECEPTACLE, MOUNTED 42" AFF TO CENTER OF OUTLET OR 2" FROM BOTTOM OF
TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 18" AFF TO CENTER OF DEVICE. SLASH
DUPLEX RECEPTACLE OUTLET. CEILING MOUNTED. SLASH INDICATES
SPECIAL RECEPTACLE OUTLET. NEMA CONFIGURATION AS INDICATED.
MODIFIERS FOR RECEPTACLES:
SPECIAL RECEPTACLE OUTLET. NEMA CONFIGURATION AS INDICATED.
LH2A-1
CH2A
EQUIPMENT CONNECTION DESIGNATION, SEE SCHEDULE FOR DETAILS.
RATING AND BOTTOM NUMERAL INDICATES NEMA STARTER SIZE.
COMBINATION MOTOR STARTER WITH FUSED SWITCH. TOP NUMERAL INDICATES FUSETRON AMPERE
LIGHTNING PROTECTION SYSTEM GROUND ROD.
75KVA
LIGHTNING PROTECTION SYSTEM AIR TERMINAL.
TR = TAMPER RESISTANT
3 = THREE WAY
MODIFIERS FOR SWITCHES:
SINGLE POLE SWITCH.
THREE SINGLE POLE SWITCHES IN A 3-GANG BOX.
PHOTO ELECTRIC CELL MOUNTED ON CONDUIT STUBBED 6" ABOVE ROOF, FACING NORTH.
SWITCHES
TWO SINGLE POLE SWITCHES IN A 2-GANG BOX.
PROVIDE DIVIDER FOR DIFFERENT VOLTAGES OR BRANCHES.
4 = FOUR WAY
D = DIMMER
DT = DOUBLE THROW
LV = LOW VOLTAGE
PROVIDE DIVIDER(S) FOR DIFFERENT VOLTAGES OR BRANCHES.
OS = OCCUPANCY SENSOR
TIME CLOCK. PROVIDE POWER CIRCUIT AND 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE.
a,b,c = MULTIPLE SWITCH LEGS
T = TIMER
INDICATED.
INDICATED. SLASH INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.
INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.
CONNECTED TO NORMAL POWER. SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTUAL RCP FOR EXACT
LUMINAIRE, 2x4, CEILING MOUNTED, CONNECTED TO THE NORMAL POWER SYSTEM (UNLESS OTHERWISE NOTED). SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT LOCATION/CEILING TYPE.
LOCATION AND CEILING TYPE. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.
SEE SCHEDULE FOR TYPE (*).
SEE SCHEDULE FOR TYPE (*).
REMOTE EMERGENCY EGRESS TWIN-LAMP UNIT.
HALF-SHADED INDICATES CONNECTED TO LIFE SAFETY BRANCH.
UNLESS NOTED OTHERWISE.
WITH EQUIPMENT SUPPLIER/INSTALLER.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. SEE SCHEDULE FOR TYPE (*).
NURSE CALL PILLOW SPEAKER.
NURSE CALL SINGLE CALL CORD.
NURSE CALL HEADEND EQUIPMENT.
FIRE ALARM SPEAKER AND VISUAL ALARM SIGNAL, CEILING MOUNTED.
HEADWALL. SEE PLAN FOR NUMBER.HW#
POWER COLUMN. SEE PLAN FOR NUMBER.PC#
POWER SYSTEM.
CONNECTED TO THE EMERGENCY POWER SYSTEM.
FLUORESCENT STRIP LUMINAIRE. CEILING MOUNTED OR SUSPENDED 8'-0" AFF TO BOTTOM OF LUMINAIRE, CONNECTED TO NORMAL POWER. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.
HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY
GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
CARD READER. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.
ELECTRIC STRIKE. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.
WALL MOUNTED LOCAL ALARM BUZZER, 85dBA.
DURESS ALARM BUTTON RECESSED IN COUNTER.
MAGNETIC LOCK FOR DOOR.
PUBLIC ADDRESS SYSTEM SPEAKER, CEILING MOUNTED.
REMOTE LINE ISOLATION MONITOR.
CABLE TV OUTLET, MOUNTED ADJACENT TO TV RECEPTACLE, UNLESS NOTED OTHERWISE.
PUSHPAD. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.
VARIABLE SPEED DRIVEVSD
FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED.
WIRELESS TELEMETRY ANTENNA
WIRELESS TELEMETRY DEVICE
EXPEDITER BUTTON PANEL
EXAM LIGHT CONTROLLER
EMERGENCY EGRESS PUSH BUTTON
KEY PAD CARD READER
FIRE ALARM SPEAKER AND VISUAL ALARM SIGNAL, WALL MOUNTED.
EMERGENCY RELEASE SWITCH. PROVIDE TAMPER RESISTANT COVER WITH A SOUNDING HORN.
RP = EXISTING DEVICE TO BE REPLACED WITH NEW DEVICE.PNEUMATIC TUBE STATIONPTS
BUTTON RELEASE.
BADGE ACCESS.
NURSE LOCATOR.
EMERGENCY MANUAL OVERRIDE.
DEVICE. INSTALL DEVICE SO IT IS CONCEALED BEHIND ENCLOSURE, COORDINATE WITH PLUMBING.
SHOWN TO CLARIFY THAT DEVICES/LUMINAIRES ON THE SAME CIRCUIT ARE CONTROLLED SEPARATELY.
POLE MOUNTED LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE (*).
SYMBOL LOCATION LEADER
POWER CONNECTION TO FIRE DAMPER. SEE DETAIL.
POWER AND FIRE ALARM CONNECTION TO SMOKE DAMPER OR FIRE/SMOKE DAMPER. SEE DETAIL.
NURSE CALL CORRIDOR DOME LIGHT, WALL MOUNT ABOVE DOOR AT 4" FROM THE TOP OF THE
DOOR FRAME TO THE BOTTOM OF THE DEVICE.
NURSE CALL CORRIDOR ZONE LIGHT, WALL MOUNT ABOVE DOOR AT 4" FROM THE TOP OF THE
DOOR FRAME TO THE BOTTOM OF THE DEVICE.
ROOM TAG
ELAPSED TIME CONTROL. MOUNT 48" AFF
BOOM LIGHT CONTROLLER
PUSH BUTTON
CONNECT LIFE SAFETY CIRCUIT TO MEDICAL GAS ALARM PANEL. 120V, 20A
WIRELESS ACCESS POINT
CODE BLUE RECEIVER
FIRE ALARM CONNECTION TO KNOX BOX.
PROVIDE DISCONNECT SWITCH AND CONNECTION TO MOTOR OPERATED DOOR. COORDINATE WITH
HARDWARE VENDOR.
INTERCOM STATION WITH BUILT IN CAMERA.
INTERCOM STATION WITH BUILT VIDEO MONITOR.
PROVIDE CONNECTION TO OWNER FURNISHED ELAPSED TIME CLOCK. MOUNT 84" AFF.
RV RM
RM
DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR. PROVIDE ONE POWER PACK FOR EACH SENSOR. COORDINATE WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.
CARBON MONOXIDE DETECTOR. CEILING MOUNT.
FIRE ALARM CONNECTION TO KNOX BOX.
FIRE ALARM CONNECTION TO AUTOMATIC DOOR.
( NOTE: SYMBOLS WITHIN THIS SCHEDULE ARE REPRESENTATIVE OF THOSE TYPICALLY FOUND ON THE DRAWINGS. ALL SYMBOLS MAY NOT APPEAR ON THIS SET OF DRAWINGS. )
GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE OUTLET. SLASH INDICATES
CONNECTED TO THE EMERGENCY POWER SYSTEM.
TAMPER RESISTENT DUPLEX RECEPTACLE OUTLET. SLASH INDICATES
CONNECTED TO THE EMERGENCY POWER SYSTEM.
LUMINAIRE, 2X2, CEILING MOUNTED, CONNECTED TO THE NORMAL POWER SYSTEM (UNLESS OTHERWISE NOTED). SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT LOCATION/CEILING TYPE.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
GENERAL PROJECT NOTES
M
C
C
30CB
DB
DT
E
F
H
GA
J
J
M
LIM
P
PE
RA
T
TC
CB
FAC
CO
AD
CL
F
CL
DD
EC
ES
FACP
FARA
FATR
FD
FS
FS
H
FSD
KB
OS
L
HL
LD
L
SD
RL
SL
SD
TD
TS
SL
BL
D
DR
ET
ETC
IC
IM
M
MGA
MOD
NA
NA
NC
NC
NBO
NCL
NB
NCL
NCS
NEC
NEB
ND
NEC
NEP
NHE
NKS
NLV
NMS
NZL
NZL
NPP
NP1
NP2
NS
PS1
SCC
TV
WA
ET
G
TR TR
G
S
ELECTRICAL - SYMBOL SCHEDULE, NOTES AND DRAWING INDEX
ELECTRICAL - DETAILS
ELECTRICAL - LUMINAIRE SCHEDULE AND DETAILS
ELECTRICAL - LIGHTNING PROTECTION DETAILS
ELECTRICAL - DETAILS
ELECTRICAL - FOURTH FLOOR - DEMOLITION PLAN
ELECTRICAL - FIFTH FLOOR - DEMOLITION PLAN
ELECTRICAL - FOURTH FLOOR - NEW WORK - LIGHTING - AREA A
ELECTRICAL - FOURTH FLOOR - NEW WORK - LIGHTING - AREA B
ELECTRICAL - FOURTH FLOOR - NEW WORK - LIGHTING - AREA C
ELECTRICAL - FOURTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA A
ELECTRICAL - FOURTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA B
ELECTRICAL - FOURTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA C
ELECTRICAL - FIFTH FLOOR - NEW WORK - LIGHTING - AREA A
ELECTRICAL - FIFTH FLOOR - NEW WORK - LIGHTING - AREA B
ELECTRICAL - FIFTH FLOOR - NEW WORK - LIGHTING - AREA C
ELECTRICAL - FIFTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA A
ELECTRICAL - FIFTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA B
ELECTRICAL - FIFTH FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA C
ELECTRICAL - ROOF PLAN - NEW WORK - POWER
E001 E002 E003 E004 E005
ED400
ED500
E400A E400B E400C E401A E401B E401C E500A E500B E500C E501A E501B E501C E600
CONNECTION TO PRE-FABRICATED HEADWALL UNIT. WITH NORMAL AND CRITICAL POWER
CIRCUITS AND COMMUNICATION SERVICES.
TWO SINGLE POLE SWITCHES IN A 2-GANG BOX. EITHER SWITCH INBOARD AND OUTBOARD LAMPS
SEPARATELY OR STEP-DIM BOTH LAMPS TO 50%.
ELECTRICAL - ROOF - DEMOLITION PLANED600
ELECTRICAL - PANEL SCHEDULESE010
ED300 ELECTRICAL - THIRD FLOOR - DEMOLITION PLAN
E100 ELECTRICAL - GROUND FLOOR - NEW WORK - POWER
ELECTRICAL - THIRD FLOOR - NEW WORK - LIGHTING - AREA CE300C
ELECTRICAL - THIRD FLOOR - NEW WORK - POWER AND SPECIAL SYSTEMS - AREA CE301C
ELECTRICAL - PANEL SCHEDULESE011
1. ALL FIXED ELECTRICAL EQUIPMENT FURNISHED BY ELECTRICAL CONTRACTOR SHALL BE LISTED AND LABELED BY AN APPROVED TESTING AGENCY APPROVED BY THE GOVERNMENT. FACTORY ASSEMBLED LISTED COMPONENTS SHALL BE LISTED AND LABELED AS AN ASSEMBLY. ANY ELECTRICAL EQUIPMENT NOT LISTED OR LABELED MUST BE APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION AND HAVE A THIRD PARTY TESTING LABEL OR SHALL BE REPLACED WITH EQUIPMENT THAT IS UL LABELED/LISTED AT THE CONTRACTOR'S EXPENSE.
2. FIRE ALARM APPLIANCES AND DEVICES SHOWN INDICATE TO PROVIDE COVERAGE IN THAT AREA. ELECTRICAL CONTRACTOR SHALL PROVIDE APPLIANCES AND DEVICES AS REQUIRED BY THE LATEST EDITION OF NFPA 72 AND LOCAL BUILDING CODE. NO CHANGE ORDERS WILL BE ALLOWED FOR APPLIANCES AND DEVICES REQUIRED BY
NFPA 72 AND THE NC STATE BUILDING CODE.
3. CONTRACTOR SHALL COORDINATE WITH THE FACILITY'S INFECTION CONTROL OFFICER TO VERIFY THAT APPROPRIATE SAFEGUARDS ARE BEING TAKEN TO PROTECT WORKERS INVOLVED IN DEMOLITION ACTIVITIES.
4. CONTRACTOR SHALL COORDINATE WITH FACILITY'S INFECTION CONTROL OFFICER TO VERIFY THAT APPROPRIATE PRECAUTIONS ARE BEING TAKEN TO PROTECT FACILITY STAFF AND PATIENTS DURING THE CONSTRUCTION
ACTIVITIES.
5. ASBESTOS CONTAINING MATERIALS (IF PRESENT) WILL BE IDENTIFIED BY THE OWNER AND WILL BE REMOVED FROM AHU'S, PIPING INSULATION, DUCT INSULATION, ETC. (IF REQUIRED) PRIOR TO CONTRACTOR BEGINNING ANY WORK
ON THE SITE. COORDINATE WITH OWNER.
6. UNLESS NOTED OTHERWISE, ELECTRICAL CONTRACTOR SHALL INSTALL ALL RACEWAY, BOXES, AND CABLES. ALL MEDICAL EQUIPMENT CABLES, UNLESS OTHERWISE NOTED, SHALL BE PROVIDED BY MEDICAL EQUIPMENT VENDOR.
ELECTRICAL - DETAILSE006
ELECTRICAL - POWER RISER DIAGRAME007
FIRE ALARM ISOLATION MODULE.ISO
DURESS ALARM SYSTEM INTRFACE CONNECTIONS.
(1 VOICE/1 DATA DENOTES QUANTITY OF VOICE/DATA OUTLETS)
* No new lighting load added.
VARIABLE FREQUENCY DRIVE.
ELECTRICAL - SITE PLANE020
CONNECTED TO THE EMERGENCY POWER SYSTEM.
VOICE/DATA OUTLET, CEILING MOUNTED.
DRAWING INDEX
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000 Project No. 3588
Charlotte Engineers, LLP
This document is the property of RPA Design and RPA Design retains all rights therein, including copyrights.
It may only be used in a manner consistent with RPA Design's rights while RPA Design is providing services for the specific project identified or referred to herein or extensions thereto.
It may not be used for any other purpose except with the express written agreement of, and compensation to, RPA Design.
Project
City, State
Project Number
Drawn By
Checked By
Seal / Signature
Sheet Title
Date
Sheet Number
Issued For
Architect of Record
5960 Fairview Road Suite 500 Charlotte, NC 28210
887.3500
887.3507 fax
Charlotte Engineers, LLP 5838 Monroe Road, Suite 100 Charlotte, NC 28212
704.531.3000 PHONE
704.531.3001 FAX
MECHANICAL/ELECTRICAL/PLUMBING/FIRE PROTECTION:
Fitzpatrick Engineering Group, PLLC 19520 West Catawba Ave., Ste. 311 Cornelius, NC 28031
704.987.9114 PHONE
704.987.9938 FAX
STRUCTURAL:
Program Manager
13620 Reese Blvd.
Suite 100
Huntersville, NC 28078
401.2040
401.2067 fax
5/ 8/
:4
3:
P M
E :\L oc al
R ev it\
\3
C E
- C en tra l M od el
.rv t
E001
ELECTRICAL - SYMBOLS
SCHEDULE, NOTES AND
DRAWING INDEX
15-0014-00
CORRECT OPERATING
ROOM DEFICIENCIES
MMF
CLH
Salisbury, NC
100% FINAL DESIGN
11/10/16
Item Date Description
S
J
F
F
RL
SD DD
COMBINATION TV RECEPTACLE OUTLET
NOTES:
A. THE TERMS PATIENT WALL SYSTEM AND HEADWALL ARE SYNONYMOUS OF
EACH OTHER AND ARE USED INTERCHANGEABLY.
B. HEADWALL ASSEMBLY AND DEVICES FURNISHED BY THE OWNER. WITH
EXCEPTION TO NURSE CALL.
C. VERIFY ARRANGEMENT WITH ARCHITECTURAL ELEVATIONS.
D. PROVIDE MULTI-PIN CONNECTION FROM BED SIDECOM CONTROLS TO LOW
VOLTAGE RELAY AT LIGHT FIXTURE.
HL LCL ADDRESSABLE
MAIN
TSFS
CL
SD
HL L
DD SD
SD
EXIT
TYPICAL FOR FLOORS 3,4 AND 5
FIRE, SMOKE, & FIRE/SMOKE DAMPER WIRING
DETAIL
NOTES:
1. ALL WIRING SHALL BE INSTALLED IN RACEWAY.
2. MULTIPLE DAMPERS CAN BE SERVED BY EACH JUNCTION BOX UP TO A MAXIMUM OF 10 AMPS PER
CIRCUIT.
WIRING FROM JUNCTION BOX
TO DISCONNECT SWITCH AND
FROM DISCONNECT SWITCH
TO DAMPER ACTUATOR BY
EC.
WIRING FROM
ELECTRICAL PANEL
TO JUNCTION BOX
PROVIDED BY EC.
FIRE, SMOKE, OR FIRE/SMOKE
DAMPER BY MC.
FIRE ALARM SYSTEM
CONNECTION,
REQUIRED FOR SMOKE
AND FIRE/SMOKE
DAMPERS.
PROVIDED
BY FIRE ALARM
CONTRACTOR.
S
NOT TO SCALE 3
TO OTHER
DAMPERS (SEE
NOTE 2)
DISCONNECT SWITCH (LEVITON #1221, OR
APPROVED EQUAL) WITH LOCKABLE
COVER ; AND INDICATOR LIGHT
(DAYTON/ZORO RED, OR APPROVED
EQUAL) MOUNTED IN STAINLESS STEEL
PLATE ON UTILITY BOX THAT IS MOUNTED
WITHIN 18 INCHES OF DAMPER ACCESS
DOOR. PROVIDE CIRCUIT LABEL ON
PLATE.
ELECTRICAL PANEL LOCATED IN
ELECTRICAL ROOM, PROVIDED BY EC.
PILOT LIGHT BY EC. ON
WHEN SWITCH IS ON.
MOUNT NEXT TO SWITCH.
NOT TO SCALEDEVICE LABELING DETAIL
PROVIDE ALL WIRING DEVICES WITH A SELF-
ADHESIVE METALLIC LABEL WITH BLACK LETTERING
INDICATING PANEL AND CIRCUIT NUMBER SERVING
THE DEVICE. THE LABEL SHALL MATCH THE
CURRENT FACILITY'S STANDARDS FOR NORMAL AND
EMERGENCY BRANCH CIRCUITS. 1/4" MINIMUM
LETTERING HEIGHT.
7FCL-3
GENERAL DETAIL NOTES:
A. COORDINATE LABELING WITH OWNER PRIOR TO INSTALLATION.
7FCL-1
NOT TO SCALEDEVICE MOUNTING DETAIL 4
TOP PLATE
STUDS
JUNCTION BOX ABOVE
CEILING MOUNTED ON
BRACKET, TOP PLATE,
OR BY THREADED
ROD FROM STRUCTURE.
HOMERUN
IN EMT.
EMT
EQUAL,
MOUNT TO
STUDS ON BOTH
SIDES.
SWITCH OR
RECEPTACLE.
10NOT TO SCALEWALL MOUNTED OCCUPANCY
SENSOR
8NOT TO SCALE
FEATURES
PATTERN: 360 DEGREES
COVERAGE: 46-186 SQ M (500-2000SF)
TIME DELAY: ADJUSTABLE 30 SECONDS TO 30 MINUTES
OPTIONS
PROVIDE DUAL RELAY IN SPACES WITH MULTIPLE SWITCHING.
CONTROL: MANUAL OFF, DUAL TECHNOLOGY, OR APPROVED EQUAL
LIGHTING CONTROL
GENERAL DESCRIPTION
HOUSING: IMPACT RESISTANT INJECTION MOLDED ABS
MOUNTING: CEILING BETWEEN 2440-3050 mm (8'-10') H
ELECTRICAL: 24 VOLT DC (FROM POWER PACK), 120 OR 277 VOLT AC
INPUT
FINISH: MATCH FACILITY'S STANDARDS
NOM. DIMENSIONS: 121 mm X 102 mm (4 3/4" DIA X 4"D)
CEILING MOUNTED OCCUPANCY
SENSOR
NOT TO SCALE 92-POLE CEILING MOUNTED OCCUPANCY SENSOR FOR
CONTROL OF DUAL LEVEL SWITCHING
N
LOAD
HN
LOAD
H
LIGHT SWITCH
LIGHTING CIRCUIT LIGHTING CIRCUIT
CONDUCTORS PER MANUFACTURER'S
PUBLISHED RECOMMENDATIONS
IN 3/4"C MINIMUM (TYPICAL)
FATC
KEY NOTES:
1. DEVICES SHOWN ARE TYPICAL. REFER TO COMMUNICATIONS SHEETS FOR DEVICE LOCATIONS
AND QUANTITIES.
2. PROVIDE END OF LINE RESISTORS AS REQUIRED.
3. ANNUNCIATION SHALL BE THREE TEMPORAL BEEPS.
4. DUCT SMOKE DETECTORS AND DAMPERS SHALL BE PROVIDED AND WIRED TO FATC AND POWER
BY ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL INSTALL THEM.
5. FOR LARGER DUCTS, PROVIDE ADDITIONAL DUCT DETECTORS AS REQUIRED BY NFPA 72.
6. NEW EQUIPMENT MUST BE COMPATIBLE WITH THE EXISTING SYSTEM.
7. CONFIRM / INSTALL SMOKE DETECTOR IS LOCATED ABOVE MASTER FIRE ALARM CONTROL PANEL
OR EXISTING FATC. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN.
8. MASTER FIRE ALARM CONTROL PANEL TO BE LOCATED IN A FIRE RATED ENCLOSURE . THE
MASTER FIRE ALARM CONTROL PANEL IS NOT REQUIRED TO BE LOCATED IN A FIRE RATED
ENCLOSURE IF THE BUILDING IS SPRINKLERED. CONFIRM / COORDINATE.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING A FIRE WATCH WHEN A FIRE ALARM
SYSTEM IS OUT OF SERVICE MORE THAN 4 OUT OF 24 HOURS OR A SPRINKLER SYSTEM IS OUT OF SERVICE MORE THAN 10 HOURS IN A 24 HOUR PERIOD IN AN OCCUPIED BUILDING. NOTIFICATION
AND FIRE WATCH TIMES ARE DOCUMENTED. PROVIDE WRITTEN VALIDATION OF FIRE WATCH
DURING OUTAGES.
10. FIRE ALARM SYSTEM IMPAIRMENT PROCEDURES SHALL COMPLY WITH NFPA 72.
FIRE ALARM RISER DIAGRAM NOT TO SCALE 12
EXISTING
RENOVATED
AREA
EXISTING
AREA
COVER PLATE AS SHOWN.
TWO GANG BACK BOX WITH
SNAP IN PLASTIC CLOSURE.
CONNECTOR. PROVIDE TEMPORARY
OPENING FOR SYSTEM
BARRIER
DUPLEX RECEPTACLE
ACCESSIBLE CEILING.
STUBBED TO ABOVE
WITH PULL STRING
3/4" EMPTY CONDUITSYMBOL:
NTS
TV
DOOR OPERATOR
DOOR DOOR
PUSH PADS
120V, 20A
CIRCUIT
TYPICAL FOR SINGLE OR DOUBLE DOORS
DOOR OPERATOR WIRING - RISER DIAGRAM 6
NTS
FLOOR
12", UNLESS CEILING IS HIGHER
THAN 12'-0", THEN 24" ABOVE DOOR.
CEILING
FLOOR
WALL MOUNTED
TELEPHONE
6" TO
TOP OF
COUNTER OR
BACKSPLASH
18"
RECEPTACLE
LIGHT SWITCH
OR DIMMER
ALIGN WHERE
POSSIBLE
TELEPHONE OR
VOICE DATA OUTLET
TV OUTLET
OR CLOCK
OUTLET
FIRE ALARM DEVICES
" A
BO
VE
FL
OO
R
TO
B
OT
TO
M
OF
D
EV
IC
E
ON
C
OL
UM
NS
MOUNTING HEIGHTS OF DEVICES
FOR WALL MOUNTED UNITS:
BOTTOM
OF DEVICE
NO
T T
O
EX
CE
ED
" T
O
BO
TT
OM
NOT TO SCALE
GENERAL DETAIL NOTES:
A. PARTICULAR ATTENTION SHALL BE GIVEN TO THE ALIGNMENT OF DEVICES. WHEREVER
DEVICES, ON THIS SHEET OR OTHER SHEETS, ARE SHOWN AT GIVEN LOCATION WITH
DIFFERENT MOUNTING HEIGHTS THEY SHALL BE ALIGNED VERTICALLY. IF THEY ARE
SHOWN AT THE SAME MOUNTING HEIGHT THEY SHALL BE ALIGNED HORIZONTALLY. REFER
TO THE ARCHITECTURAL PLANS, ELEVATIONS AND DETAILS. COORDINATE WITH
ARCHITECT PRIOR TO ROUGH-IN.
B. ALL DIMENSIONS ARE TO THE CENTER LINE OF DEVICE UNLESS INDICATED OTHERWISE.
C. MOUNTING HEIGHTS SHOWN HERE ARE TYPICAL. PRIOR TO ROUGH-IN, COORDINATE WITH
ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS. IF A CONFLICT OCCURS, REQUEST
CLARIFICATION FROM ARCHITECT/ENGINEER PRIOR TO ROUGH-IN.
D. COORDINATE MOUNTING HEIGHTS WITH "OR" AND BIOMED STAFF.
6"
A
A
Section A-A
1. RATED WALL OR FLOOR ASSEMBLY - PROVIDE FIRE STOPPING
ASSEMBLY FOR PARTITION TYPE & RATING ENCOUNTERED.
2. THROUGH PENETRATION - PROVIDE FIRE STOPPING ASSEMBLY FOR
SIZE & MATERIAL OF THROUGH PENETRATION UTILIZED.
3. FIRE STOPPING MATERIAL - PROVIDE FIRE STOPPING MATERIAL FOR
WALL ASSEMBLY & THROUGH PENETRATION MATERIAL ENCOUNTERED. FILL VOIDS OR CAVITY
ACCORDING TO THE REQUIREMENTS OF THE FIRE STOPPING SYSTEM UTILIZED.
ALL RATED WALLS, PARTITIONS OR FLOORS SHALL BE PROVIDED WITH A UL LISTED FIRE STOP SYSTEM. THE SYSTEM UTILIZED SHALL MATCH THE SEPARATION PENETRATED AND THE THROUGH
PENETRATION MATERIAL.
DETAILS FOR THE INSTALLATION OF SYSTEM TYPE UTILIZED SHALL BE AVAILABLE AT THE PROJECT SITE FOR THE DURATION OF CONSTRUCTION AND SHALL BE PROVIDED TO THE AUTHORITY HAVING
JURISDICTION AND TO THE BUILDING OWNER AT THE PROJECT COMPLETION.
PROVIDE WALL OR FLOOR LABLES INDICATING THE SYSTEM MANUFACTURER AND UL LISTED
ASSEMBLY NUMBER AT EACH LOCATION WHERE THE FIRE STOPPING SYSTEM IS INSTALLED.
NOT TO SCALE
THROUGH PENETRATION FIRESTOP SYSTEM 5(PROVIDE UL…