About this file

36A77619Q0023 0008 P09 - SOW - Rev 06FEB2019 - Amendment 0008.docx

View the file

Other files for this federal contract opportunity

Other files attached to 36A77619Q0023 ScriptPro Pharmacy System Equipment Chico Package 32 612A90048 Pharmacy System Equipment (VA-18-00117631), newest first.
File Type Posted
-16445.docx DOCX document
36A77619Q0023-0008000.docx DOCX document
36A77619Q0023-0007000.docx DOCX document
36A77619Q0023_0006.docx DOCX document
36A77619Q0023_0005.docx DOCX document
36A77619Q0023_0004.docx DOCX document
36A77619Q0023_0003.docx DOCX document
36A77619Q0023_0002.docx DOCX document
36A77619Q0023-0001001.docx DOCX document
36A77619Q0023-0001000.docx DOCX document
36A77619Q0023-005.docx DOCX document
36A77619Q0023-004.pdf PDF
36A77619Q0023-003.docx DOCX document
36A77619Q0023-002.pdf PDF
36A77619Q0023-001.docx DOCX document
36A77619Q0023-000.docx DOCX document
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA Northern California Health Care System 10535 Hospital Way Mather, CA 95655

VA Northern California Health Care System Initial Outfitting, Transition & Activation Statement of Work Pharmacy System Equipment

Revision: 2/6/2019 – Amendment 0008 Approved By:

Date:

VA Northern California Health Care System 10535 Hospital Way Mather, CA 95655

Statement of Work Pharmacy System Equipment

Introduction Veteran Affairs Northern California Health Care System (VANCHCS) has a requirement to purchase Pharmacy System Equipment from ScriptPro identified in Table 1 below. This requirement is in support of the activation of the Chico VA Clinic. Item(s) are to be delivered and installed to VANCHCS Chico VA Clinic.

Table 1 – Package Items Summary

Item Number
Item Description
Quantity
M7280
Dispenser, Medication, Robotic – ScriptPro CRS
1
M7280-E
Computer Workstation, Data Mgt, Pharmacy ScriptPro SP Central Platform w/Datapoint
1
M7280-A
Pharmacy Data Terminal, Control Station, Prescription, Robotic –

ScriptPro SP Datapoint

Part of M7280-A
KVM Emulation and Setup up
1
Part of M7280-A
KVM Device
6
M7280-B
Pharmacy Printer, Label, Barcode – ScriptPro SP Printer
3
M7280-C
Prescription Notification Board, Message, Electronic – ScriptPro NOTICEBOARDXL
1
M7280-F
Signature Pad, Electronic
2
M7280-G
Rx Paperwork Printer
2
F2700
Reader, Bar Code, Hand Held, With Interface – ScriptPro Wireless Scanner
2
Part of M7280-E
Standard Interface
2
Part of M7280-E
Data Management for Central Platform
1
Part of M7280-E
SP Data Point Workstation
1
Part of M7280-E
Virus Protection Interface Upgrade (Platform)
1
All
Monthly Support
5
All
Installation
1

General Conditions Site Address The address of the VANCHCS Chico VA Clinic is provided below. Further information on delivery is located in section 2.4.

Chico VA Clinic 1601 Concord Avenue Chico, CA 95928 Delivery Schedule Items shall be delivered no earlier than the estimated delivery start date and no later than the delivery end date listed in Table 2 below.

Table 2 – Anticipated Building Outfitting Schedule

Building Name
Building # & Letter
Acronym
Est. Delivery Start Date
Est. Delivery End Date

Chico VA Clinic

Site
No earlier than 4/15/19
NLT 5/15/19

Schedule and Order Management The above delivery schedule is based upon the current construction schedule. The vendor shall not increase prices for a change in delivery date for up to 30+ days due to construction delays.

The awardees actual delivery dates will be confirmed by VA upon award.

Post-award the vendor will coordinate delivery prior to beginning any work (see section 2.4). Once the dates have been confirmed, modifications to the schedule are subject to written approval by the COR and the vendor. Schedule changes that are beyond the dates specified in the contract will require approval by the Contracting Officer and a contract modification.

Delivery and Receiving Delivery and receipt of the proposed items is anticipated to be directed to the location identified below. Confirmation of delivery location will be provided post-award. To coordinate delivery, contact Government POC Antonio Homer at (916) 843-7393, Antonio.homer@va.gov and Angela Howard at (217) 274-8933, angela.howard@goenergistics.com or Jack O’Dell at (937) 608-7329, jack.odell@goenergistics.com.

☒ VANCHCS Chico VA Clinic (Direct Delivery to address detailed in paragraph 2.1.1) ☐ IOT&A Contractor-Provided Warehouse Local to the VANCHCS Go Energistics Warehouse: Attn: GoE-VA Project, 13290 Contractor Dr., Chico, CA 95928 The delivery of items identified in this document shall take place during normal business hours which are defined as: 0800 to 1630 (i.e.: 8:00am to 4:30pm Pacific Standard Time), Monday through Friday, and excluding Federal Holidays.

Delivery trucks will not be permitted to remain at the loading dock. Trucks shall be unloaded, moved from the dock, and then brought back to the dock if required to haul out any waste, tools, or excess materials.

Labeling of delivered items shall include the VA facilities contract number and VA purchase order number for identification and reference upon receipt of product.

Use of Warehouse If the vendor requires the use of the Government’s activation contractor’s warehouse to meet the requirements of this contract the vendor must provide a certificate of insurance prior to the delivery and offloading of the item(s). This insurance certificate must be completed and presented to the activation contractor prior to delivery.

The vendor shall communicate through the VA POC any required coordination requirements.

Clean Up and Disposal There are no dumpsters available for vendor use.

The removal of waste and/or excess material shall be conducted through the loading dock area.

Deliverables The vendor shall provide a completed 6550 form with submittal documents for any and all item(s) that may connect to the VA network and medical devices that store sensitive patient information.

Assembly and Installation The vendor is required to manage and coordinate installation at the VANCHCS Chico VA Clinic with the COR.

On-site assembly and installation of items, and performance of services identified in this document shall take place during normal business hours which are defined as: 0800 to 1630 (i.e.: 8:00am to 4:30pm Pacific Standard Time), Monday through Friday, and excluding Federal Holidays.

The vendor is required to define the need for a staging area to accommodate item assembly and installation, if needed. Post-award, this information will be confirmed with the vendor.

The vendor is required to provide tools, labor and materials to complete assembly and installation of the items detailed in this document.

The vendor shall protect all finished spaces and surfaces as required from delivery and installation damage. The vendor shall use covering and protection to the extent necessary to prevent damage to finished spaces. Any damage occurred during delivery and installation is the responsibility of the vendor. The vendor will be responsible for paying for and repairing any damage or noted deficiencies to finished spaces and surfaces that occur as a result of the vendor’s (or associated sub-contractors) installation.

During the entire duration of assembly and installation, the vendor will have a competent representative on-site as the vendor’s contact, and to serve as the interface between the vendor and VANCHCS. On-site representative can be the installer. All instructions provided from COR to the representative will be binding as if given to the vendor’s main contact. The COR may provide specific instructions, however, only the Contracting Officer may change the terms or conditions of the contract.

Training The vendor shall provide end-user training for routine operation and maintenance, fault/alarm identification and response, and basic trouble-shooting, at a minimum. Training format may be hands-on, pre-recorded, internet based and/or O&M manual based. Training must be coordinated with the VA POC prior to installation or first use of equipment.

For on-site, vendor conducted training, the vendor will document the training and provide a copy of all training materials to the VA POC. Documentation may be up to and including video of training session conducted on site.

The vendor shall provide service training, if required by item, up to and including preventive maintenance, diagnostics and repair. Training shall be completed within 45 days after final installation of equipment or as directed by the VA. The vendor will document the training and provide a copy of the training materials to the VA POC”

VA Northern California Health Care System F2700

1601 Concord Avenue

Chico, CA 95928

Project: Chico VA Clinic

Total Quantity: 2

☐ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked ☐ BMET Training Required if Checked ☐ End User Training Required if Checked

Item Name: Reader, Bar Code, Hand Held, With Interface

Salient Characteristics:

Wireless Scanner shall interface with ScriptPro system Wireless Scanner cradle (charger/communication base) USB connected to SP Datapoint Power Supply: 2.5 W (0.5 A @ 5 V) with USB (Charging), 0.625 W (0.125 A @ 5 V) (Non- Charging); 4-5.5 VDC, 2.3 W (450mA @ 5 VDC) (Operating), 0.45 W (90mA @ 5 VDC) (Standby)

VA Northern California Health Care System M7280

Project: Chico VA Clinic

Total Quantity: 1

☐ BMET Training Required if Checked ☒ End User Training Required if Checked

Item Name: Dispenser, Medication, Robotic

Salient Characteristics:

· Medication dispensing pharmacy robot system. System supports up to 75 dispensing cells and dispenses tablets and capsules of all shapes and sizes into standard pharmacy vials. System uses a computer controlled robotic arm to fill vials directly from medication dispensing cells.

· Compact Robotic prescription dispensing system

· System uses computer controlled robotics to fill vials directly from medication dispensing cells

· 7 sq. foot footprint

· No drug cross contamination

· Floor standing unit

· Ability to fill up to (150) vials per hour

· Up to (75) Medication dispensing cells

· Can support a large variety of vial types and sizes

· Filling system that prevents drug cross-contamination

· Ethernet connection

· Power supply: 100-125 VAC ±10%, 50/60 Hz, 6 AMP, 1 Phase, Uninterruptible Power Supply included. Dedicated 20 AMP power outlet located within 10 feet (3m) of power connection.

VA Northern California Health Care System M7280A

Project: Chico VA Clinic

Total Quantity: 4

Item Name: SP Datapoin Pharmacy Data Terminal

Salient Characteristics:

Compact, interactive countertop unit. Allow pharmacy workers to enter, fill, verify, dispense and track prescriptions. Touchscreen monitor, keyboard, mouse and CCD barcode scanner included.

Data management workstation for pharmacy robot system Allows pharmacy workers to enter, fill, verify, dispense and track prescriptions Touchscreen monitor, keyboard, mouse and CCD barcode scanner included Power supply: 115-240 VAC ±10%, 50/60Hz, 1.4-0.7 AMP, 1 Phase. Outlet located within 5 feet (1.5m) of power connection Accessories Includes terminal KVM switch (6)set up for toggling between VHA Vista computer and Script Pro workstation KVM Terminal Emulation/Service and KVM Setup

VA Northern California Health Care System M7280B

Project: Chico VA Clinic

Total Quantity: 3

Item Name: Printer, Label, Barcode (SP Printer- Pharmacy Printer)

Salient Characteristics:

Works with SP Datapoint to produce high quality direct thermal prescription labels.

Interfaces with ScriptPro’s SP Central software to ensure the user scans the correct product code before printing the prescription label.

Counter mounted Dimensions: 14" W x 12" D x 7" H (horizontal mounting configuration) Power supply: “100-240 VAC ±10%, 50/60 Hz, 2-1 AMP, 1 Phase. Outlet located within 5 feet (1.5m) of power connection.

VA Northern California Health Care System M7280C

Project: Chico VA Clinic

Total Quantity: 1

Item Name: Board, Message, Electronic

Salient Characteristics:

Monitor Displaying patient name and status located in lobby areas to alert patients that prescriptions are ready for pickup. Connected to CRS software system which automatically updates board once final step in prescription filling is completed. Board comes with wall mount. Message board- 42” flat panel monitor Message board 42” flat panel monitor located in lobby areas to alert patients that prescriptions are ready for pickup Connected to M7280 software system which automatically updates board once final step in prescription filling is completed Monitor comes with wall mount (Customer Responsibility to mount) Electrical: 120V cord and plug Power supply: 120 Volts, 60 Hertz, Phase 1, 10 Amps, 1200 Watts

VA Northern California Health Care System M7280E

Project: Chico VA Clinic

Total Quantity: 1

Item Name: Computer Workstation, Data Mgt, Pharmacy

Salient Characteristics:

Data management software. Connects components of the robot system. Stores data for the robot as well as patient information.

Central server for the robot workflow system System provides centralized management and data processing System stores prescription processing data and electronic signatures for prescription dispensing Includes:

(2) wireless barcode scanners

(1) for the Rx printer

· (2) standard interfaces, 1 for the vista computer and the Virus Protection Interface upgrade are to be quoted separately

· Dimensions: 20" W x 24" D x 6" H (approximate dimensions for desktop configuration)

· Power supply: 100-240 VAC, 50/60 Hz, 2.5 AMP without UPS, 2.9 with UPS, 1 Phase. Grounded outlet located within 5 feet (1.5 m) of power connection.

VA Northern California Health Care System M7280F

Project: Chico VA Clinic

Total Quantity: 2

Item Name: Signature Pad, Electronic

Salient Characteristics:

Electronic signature pad.

Electronically captures signature of anyone picking up a prescription.

Interfaces with SP Central system to store and track who was the receiver of medications Shall plug into a computer via USB Attached Stylus for signing Power supply: 12W, 12-24VDC, power pack input requirements: 100-240VAC, 50/60Hz

VA Northern California Health Care System M7280G

Project: Chico VA Clinic

Total Quantity: 2

Item Name: Printer, Prescription, Paper

Salient Characteristics:

Network capable desktop printer Printer shall interface with ScriptPro system Include Rx Paperwork Printer Bar Code Card Prints 8.5" x 11" paper Network capable Rx Paperwork printer Printer shall interface with ScriptPro system Rx Paperwork Printer Bar Code Card required at additional cost Prints 8.5" x 11" paper image1.jpeg