3-KW Library Roof Replacement Drawings 4 May 2026.pdf
PDF 11 MB Posted
- Attached to
- Key West Library Roof Replacement
- Solicitation number
- RFP-637
- Issued by
- Monroe County, Florida
About this file
This file contains roof replacement design drawings for the Monroe County Public Library Key West Branch, prepared by Keister Webb Structural Engineers LLC and Bender & Associates Architects, PA. The drawings specify structural and design criteria for replacing the existing roof at the 15,400-square-foot facility located at 700 Fleming Street, Key West, Florida. The project follows the Florida Building Code, Eighth Edition (2023) and ASCE/SEI 7-22 standards, with design wind loads calculated for an ultimate design wind speed of 180 miles per hour and nominal design wind speed of 140 miles per hour under Risk Category II exposure. The structural drawings include detailed component and cladding wind pressure tables and zone diagrams for flat, gable, and hip roof configurations, with effective areas ranging from 10 to 100 square feet and wind pressures varying by zone and area.
The technical specifications establish requirements for structural lumber (minimum No. 2 grade Southern Pine with specified design stresses), structural steel (ASTM A36), fasteners (5/8-inch diameter ASTM A307 bolts), wood panels and sheathing (3/4-inch minimum thickness APA Rated Sheathing Structural I with Exposure 1 classification), and connection details using Simpson Strong-Tie hangers and anchors. All roof structural panels must be nailed with 10d spiral or ring shank nails at spacing ranging from 4 to 6 inches on center depending on wind zone, with end joints located over supports and rows staggered. The contractor is required to submit shop drawings for review and approval, verify existing conditions before beginning work, and engage qualified inspection and testing agencies subject to architect approval. All pressure-treated lumber must comply with AWPA Standards C2 and LP-22, and the contractor bears responsibility for design and installation of any alternate connection details proposed as substitutes for those specified on the drawings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A0.0
M
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
MONROE COUNTY PUBLIC LIBRARY - KEY WEST BRANCH
M O N R O E C O U N T Y B O A R D O F C O U N T Y C O M M I S S I O N E R S 7 0 0 F L E M I N G S T R E E T K E Y W E S T , F L O R I D A
ROOF REPLACEMENT
Haven Burkee DS Stamp
A0.1
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
D1.1
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A1.1
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A1.2
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A2.1
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A2.2
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A5.1
A8.1
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A8.2
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A8.3
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A8.4
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
A8.5
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
FLAT ROOF COMPONENT AND
CLADDING WIND PRESSURE
EFFECTIVE
AREA (SF)
ROOF ZONE
ALL ZONES 1F 2F
10 +29 -113 -149 20 +27 -105 -139 50 +25 -96 -127
100 +23 -88 -117
GABLE ROOF COMPONENT AND CLADDING WIND PRESSURE
EFFECTIVE
AREA (SF)
ROOF ZONE OVERHANG ZONE
ALL ZONES 1G 2G 3G 1G 2G 3G
10 +48 -102 -163 -194 -152 -213 -244 20 +44 -93 -140 -165 -139 -186 -211 50 +38 -80 -108 -126 -122 -150 -168
100 +34 -70 -85 -97 -109 -123 -136
HIP ROOF COMPONENT AND CLADDING
WIND PRESSURE
EFFECTIVE
AREA (SF)
ROOF ZONE OVERHANG
ALL ZONES 1H 2H/3H 1H/2H/3H
10 +54 -96 -132 -182 20 +46 -85 -114 -160 50 +37 -71 -90 -132
100 +30 -60 -72 -110
NOTES:
1. POSITIVE WIND PRESSURES ACT TOWARDS THE BUILDING SURFACE. NEGATIVE WIND PRESSURES ACT
AWAY FROM THE BUILDING SURFACE.
2. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN, THE PRESSURE ASSOCIATED WITH THE LOWER EFFECTIVE
AREA SHALL BE USED.
3. TABULATED COMPONENT AND CLADDING PRESSURES HAVE BEEN CALCULATED IN ACCORDANCE WITH THE DESIGN BUILDING CODE PER NOTE 100.1 BASED ON THE ULTIMATE DESIGN WIND SPEED (Vult) PER
NOTE 100.3A AND SHOULD BE USED IN CONJUNCTION WITH ASCE 7-22 LOAD COMBINATIONS.
TABULATED PRESSURES CAN BE CONVERTED TO NOMINAL VALUES BY MULTIPLYING BY 0.6.
COMPONENTS AND CLADDING
ZONE DIAGRAM
3G 3G 3G 3G2G 2G
1G 1G
3' -0
3'-0" 3'-0"
2G 2G
1G 1G
2F
'-0
'-0
1F
2F
2G2G 2G 2G 3H
3H 3H 3H 3H
3H
3H
3H
3H
3H
3H 3H
3H
3H
3H
6'-0"
6' -0
6' -0
6'
-0
6'-0"
6'-0"
6'-0"
6'-0"
6'-0"
2H
2H 2H
2H
2H
3H
2H
2H
1H
2G
2G
2G
2G
1G
1G
3G 3G 2H
2H
2H
2H
2H
1H
2G
2G
6'-0"
6' -0
GENERAL NOTES
100. DESIGN CRITERIA
100.1 DESIGN BUILDING CODE:
A. FLORIDA BUILDING CODE, EIGHTH EDITION (2023)
B. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE/SEI) 7-22, MINIMUM
DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER
STRUCTURES
100.2 DESIGN LOADS:
A. LIVE LOAD
PITCHED ROOF 20 PSF
100.3 WIND LOAD (ASCE/SEI 7-22)
ULTIMATE DESIGN WIND SPEED (Vult) 180 MPH NOMINAL DESIGN WIND SPEED (Vasd) 140 MPH
RISK CATEGORY II
EXPOSURE CATEGORY C
ENCLOSURE CLASSIFICATION ENCLOSED
INTERNAL PRESSURE COEFFICIENT (GCpi) +/- 0.18
SEE COMPONENTS AND CLADDING DESIGN WIND PRESSURE TABLE
AND DIAGRAM
110. GENERAL
110.1 THESE DRAWINGS HAVE BEEN PRODUCED ENTIRELY ON BENDER &
ASSOCIATES ARCHITECTS, PA CADD SYSTEM. ANY OTHER LETTERING, LINES,
OR SYMBOLS, OTHER THAN PROFESSIONAL STAMPS AND SIGNATURES,
HAVE BEEN MADE WITHOUT THE AUTHORIZATION OF KEISTER WEBB
STRUCTURAL ENGINEERS LLC AND ARE INVALID.
110.2 THE ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL
DIMENSIONS.
110.3 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ONLY DIMENSIONS
INDICATED ON DRAWINGS MAY BE USED TO ESTABLISH THE LOCATION AND
EXTENT OF STRUCTURAL WORK. IF A REQUIRED DIMENSION IS NOT
FURNISHED ON DRAWINGS, THE CONTRACTOR SHALL SUBMIT A REQUEST
FOR INFORMATION TO OBTAIN THE DIMENSION.
110.4 UNLESS OTHERWISE INDICATED, PROVIDE EQUAL SPACING OF STRUCTURAL
COMPONENTS BETWEEN OVERALL DIMENSIONS INDICATED ON DRAWINGS.
110.5 THE METHOD AND FREQUENCY OF ATTACHING MECHANICAL EQUIPMENT
UNITS, ETC., TO THE STRUCTURAL ELEMENTS SHALL BE SUBJECT TO THE
ENGINEER'S REVIEW AND APPROVAL.
110.6 UNLESS OTHERWISE INDICATED, STRUCTURAL COMPONENTS SUPPORTING
MECHANICAL EQUIPMENT HAVE NOT BEEN DESIGNED FOR THE VIBRATIONAL
EFFECTS OF THE EQUIPMENT. THE CONTRACTOR SHALL PROVIDE
VIBRATION ISOLATORS FOR ANY MECHANICAL EQUIPMENT MOUNTED TO
THE STRUCTURE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S
RECOMMENDATIONS.
110.7 THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS,
ETC., AND SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES,
ADDITIONAL INFORMATION, ETC., BEFORE BEGINNING THE WORK.
110.8 THE CONTRACTOR SHALL USE EXTREME CAUTION IN THE DEMOLITION OF
EXISTING STRUCTURES. SUCH DEMOLITION SHALL BE PERFORMED IN SUCH
A MANNER AS TO MAINTAIN THE STRUCTURAL INTEGRITY OF ALL EXISTING
STRUCTURES TO REMAIN. PROVIDE SHORING AS REQUIRED.
110.9 STRUCTURAL WORK SHALL BE INSPECTED IN ACCORDANCE WITH ALL LOCAL
ORDINANCES. THE CONTRACTOR SHALL ENGAGE AN EXPERIENCED,
QUALIFIED INSPECTION AGENCY, SUBJECT TO THE REVIEW OF THE
ARCHITECT, TO PERFORM ALL INSPECTION WORK, AS REQUIRED.
110.10 STRUCTURAL WORK SHALL BE TESTED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE GENERAL NOTES. THE CONTRACTOR SHALL
ENGAGE AN EXPERIENCED, QUALIFIED TESTING AGENCY, SUBJECT TO THE
REVIEW OF THE ARCHITECT, TO PERFORM ALL TESTING WORK, AS
REQUIRED.
120. SHOP DRAWINGS AND DELEGATED DESIGN SUBMITTALS
120.1 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW BY
BENDER & ASSOCIATES ARCHITECTS, PA.
120.2 SHOP DRAWINGS TO BE SUBMITTED SHALL PROVIDE COMPLETE
INFORMATION FOR THE PRODUCTS OR COMPONENTS TO BE SUPPLIED.
120.3 ALL SHOP DRAWING RESUBMITTALS AND RECORD COPY SUBMITTALS SHALL
HAVE ALL REVISIONS SUBSEQUENT TO THE PREVIOUS SUBMISSION
CLOUDED OR OTHERWISE IDENTIFIED ON THE RESUBMITTED SHEETS.
RESUBMITTALS AND RECORD COPY SUBMITTALS WITHOUT IDENTIFICATION
OF REVISIONS WILL BE REJECTED WITHOUT REVIEW.
120.4 THE CONTRACTOR SHALL NOT DIRECTLY INCORPORATE THE
ARCHITECTURAL DRAWINGS, OR PORTIONS THEREOF, INTO SHOP
DRAWINGS OR ERECTION DRAWINGS TO BE SUBMITTED FOR THIS PROJECT
WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION OF BENDER
& ASSOCIATES ARCHITECTS, PA. SUBMITTED SHOP DRAWINGS WHICH
CONTAIN COPIES OR REPRODUCTIONS OF ANY PORTION OF THE
ARCHITECTURAL DRAWINGS WITHOUT THE EXPRESS WRITTEN PERMISSION
OF BENDER & ASSOCIATES ARCHITECTS, PA WILL BE RETURNED REJECTED.
PERMISSION FOR A SPECIFIC CONTRACTOR OR SUB-CONTRACTOR TO USE
PORTIONS OF THE ARCHITECTURAL DRAWINGS IN THEIR PREPARATION OF
SHOP DRAWINGS REQUIRES THAT CONTRACTOR OR SUB-CONTRACTOR TO
ENTER INTO A WRITTEN AGREEMENT WITH BENDER & ASSOCIATES
ARCHITECTS, PA AND TO PAY A SERVICE FEE. SUCH AGREEMENT IS
NON-TRANSFERRABLE AND IS EXTENDED ONLY TO THAT CONTRACTOR FOR
THE DURATION OF THIS PROJECT.
120.5 THE CONTRACTOR SHALL SUBMIT ELECTRONIC OR PRINTED COPIES OF
SHOP DRAWINGS (ELECTRONIC COPIES ARE PREFERRED). COPIES SHALL BE
SUBMITTED TO BENDER & ASSOCIATES ARCHITECTS, PA IN PDF FILE
FORMAT, WITH ONE (1) ELECTRONIC FILE PER SUBMISSION. BENDER &
ASSOCIATES ARCHITECTS, PA WILL REVIEW, ANNOTATE, AND RETURN ONE
(1) FILE TO THE ARCHITECT FOR THEIR REVIEW AND DISTRIBUTION TO THE
CONTRACTOR.
120.6 THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS FOR THIS
PROJECT IS FOR CONFORMANCE WITH THE DESIGN CONCEPT AND FOR
GENERAL COMPLIANCE WITH THE INFORMATION CONTAINED IN THE
CONTRACT DOCUMENTS. COMMENTS REGARDING THESE SUBMITTALS DO
NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE CONTRACT
DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING HIS
WORK IN A SAFE AND SATISFACTORY MANNER.
610. STRUCTURAL LUMBER
610.1 ALL STRUCTURAL LUMBER WORK SHALL BE IN ACCORDANCE WITH THE
"NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION WITH
2015 NDS SUPPLEMENT" (ANSI/AWC NDS-2018) PUBLISHED BY THE AMERICAN
WOOD COUNCIL.
610.2 ALL STRUCTURAL LUMBER SHALL BE AS A MINIMUM NO. 2 GRADE SOUTHERN
PINE AND SHALL HAVE AT LEAST THE FOLLOWING MINIMUM ALLOWABLE
DESIGN STRESSES (NOT INCORPORATING THE SIZE ADJUSTMENT FACTOR
(CF)) AND MODULUS OF ELASTICITY AT A MAXIMUM MOISTURE CONTENT OF
19%:
A. Fb.(BENDING) 750 PSI B. Fv.(SHEAR) 175 PSI C. Fc.(COMPRESSION) 1,250 PSI D. Ft.(TENSION) 450 PSI
E. E 1,400,000 PSI
610.3 ALL LUMBER SHALL COMPLY WITH PS 20 "AMERICAN SOFTWOOD LUMBER
STANDARD" AND WITH THE APPLICABLE RULE OF INSPECTION AGENCIES
CERTIFIED BY AMERICAN LUMBER STANDARD. FACTORY-MARK EACH PIECE
OF LUMBER WITH GRADE STAMP OF INSPECTION AGENCY EVIDENCING
COMPLIANCE WITH GRADING RULE REQUIREMENTS.
610.4 STRUCTURAL STEEL PLATES, ANGLES, ETC., SHALL BE ASTM A36.
CONTRACTOR TO SUBMIT SHOP DRAWINGS ON ALL MISCELLANEOUS
METALS FOR REVIEW BY STRUCTURAL ENGINEER.
610.5 ALL BOLTS SHALL BE 5/8" DIAMETER ASTM A307 UNLESS NOTED OTHERWISE
WITH 2 WASHERS PER BOLT UNLESS OTHERWISE NOTED.
610.6 NO CUTS, HOLES, OR COPES REQUIRED FOR OTHER TRADES IN
STRUCTURAL WOOD FRAMING WILL BE PERMITTED WITHOUT PRIOR REVIEW
AND APPROVAL OF ENGINEER AND ARCHITECT.
610.7 PRESSURE TREAT WITH WATER-BORNE PRESERVATIVES ALL LUMBER FOR
SILL PLATES AND OTHER WOOD WHICH MAY BE EXPOSED TO WEATHER OR
EARTH. PRESSURE TREATMENT SHALL COMPLY WITH REQUIREMENTS OF
AWPA STANDARDS C2 AND LP-22.
610.8 ALL WOOD JOISTS BEARING ENDS SHALL BE ANCHORED TO SUPPORT IN
WOOD FRAMING WITH A TYPE A34 FRAMING ANCHOR, AS MANUFACTURED
BY SIMPSON STRONG-TIE COMPANY, INC.
610.9 ALL WOOD JOIST OR HEADERS ENDS WHICH FRAME INTO BEAMS SHALL BE
HUNG WITH THE FOLLOWING JOISTS HANGERS, AS MANUFACTURED BY
SIMPSON STRONG-TIE COMPANY, INC., OR WITH APPROVED SUBSTITUTES
WITH THE FOLLOWING WORKING LOAD CAPACITIES.
JOIST SIMPSON LOAD
SIZE HANGER CAPACITY
2X6 U26 705 LBS.
2X8 U26 705 LBS.
2X10 U210 1,175 LBS.
2X12 U210 1,175 LBS.
2-2X6 HU26-2 990 LBS.
2-2X8 HU28-2 1,303 LBS.
2-2X10 HU210-2 1,666 LBS.
2-2X12 HU212-2 2,016 LBS
610.10 ALTERNATE CONNECTION DETAILS MAY BE USED IF SUCH DETAILS ARE
SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL. HOWEVER, THE
ENGINEER SHALL BE THE SOLE JUDGE OF ACCEPTANCE AND THE
CONTRACTOR'S BID SHALL ANTICIPATE THE USE OF THOSE SPECIFIED
DETAILS SHOWN ON THE DRAWINGS THE CONTRACTOR IS RESPONSIBLE
FOR THE DESIGN OF SUCH ALTERNATE DETAILS WHICH HE PROPOSES.
620. STRUCTURAL WOOD PANELS/WOOD SHEATHING
620.1 FURNISH PANELS THAT ARE EACH FACTORY MARKED WITH A
CERTIFICATION STAMP EVIDENCING COMPLIANCE WITH GRADE AND SPAN
RATING REQUIREMENTS. THE CENTER-TO-CENTER SPACING IN INCHES
SHALL NOT EXCEED THE SPAN RATING STAMPED ON THE PANELS.
INSTALLATION OF THE PANELS SHALL BE IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE APA.
620.2 PANELS SHALL COMPLY WITH USDOC PS-1 OR PS-2 AND APA PRP-108 AND
SHALL MEET THE FOLLOWING REQUIREMENTS:
A. ROOF SHEATHING:
1. MIN. THICKNESS = 3/4" MATCH EXISTING
2. BOND CLASSIFICATION = EXPOSURE 1 EXTERIOR
3. GRADE = APA RATED SHEATHING STRUCTURAL I
4. SPAN RATING = AS REQUIRED TO SUIT JOIST/TRUSS SPACING
620.3 ALL PANELS WHICH HAVE ANY EDGE OR FACE PERMANENTLY EXPOSED TO
THE WEATHER SHALL BE CLASSED EXTERIOR, EXCEPT OPEN SOFFITS OR
ROOF SHEATHING EXPOSED ON THE UNDERSIDE MAY BE CLASSED
EXPOSURE 1.
620.4 ALL ROOF PANELS SHALL HAVE THE END JOINTS LOCATED OVER
SUPPORTS AND SHALL HAVE THE ROWS STAGGERED ONE HALF PANEL
LENGTH FROM ADJACENT PANELS. PROVIDE 1/8" SPACE AT PANEL ENDS
AND EDGES.
620.5 ALL ROOF STRUCTURAL PANELS SHALL BE NAILED WITH 10d SPIRAL OR
RING SHANK NAILS AT 6" OC AT ZONES 1 AND 2; 4" OC IN ZONE 3.
SHEATHING SHALL BE NAILED AT ALL ENDS AND INTERMEDIATE SUPPORTS.
EDGES SHALL BE NAILED IF BLOCKING IS CALLED FOR ON DRAWINGS
REFER TO COMPONENT AND CLADDING WIND PRESSURE DIAGRAM FOR
LOCATION OF ROOF ZONES.
620.6 ALL PLYWOOD PANELS SHALL COMPLY WITH THE WIND UPLIFT
REQUIREMENTS OF NM519 [NM520] FOR FULLY-WIND-RESISTIVE ROOF
ASSEMBLIES COMPLYING WITH UL CLASS 90 CLASSIFICATION.
M
ON
RO
E
CO
UN
TY
P
UB
LI
C
LI
BR
AR
Y
KE
Y W
ES
T
BR
AN
CH
FL
EM
IN
G
S
TR
EE
T, KE
Y
W
ES
T F
LO
RI
DA
MO
NR
OE
C
OU
NT
Y
BO
AR
D
OF
C
OU
NT
Y
CO
MM
IS
SI
ON
ER
S
R O
O F
R
EP
LA
C
EM
EN
T
6501 Arlington Expressway Building B, Suite 201 Jacksonville, FL 32211 p 904.619.2333 www.kwengineers.com
© Copyright KW 2026 KW Project #25-163
KEISTER WEBB STRUCTURAL ENGINEERS LLC S1.1
AutoCAD SHX Text
AutoCAD SHX Text Project N :
AutoCAD SHX Text
OF --
AutoCAD SHX Text Bender & Associates
AutoCAD SHX Text
ARCHITECTS
AutoCAD SHX Text p.a.
AutoCAD SHX Text Facsimilie (305) 296-2727
AutoCAD SHX Text Key West, Florida 33040
AutoCAD SHX Text 410 Angela Street
AutoCAD SHX Text Telephone (305) 296-1347
AutoCAD SHX Text Florida License AAC002022
AutoCAD SHX Text Date:
AutoCAD SHX Text 3/30/26
AutoCAD SHX Text
MARK J KEISTER PE 37435
Haven Burkee Textbox
| 25-163 GEN NOTES & CC S1.1.pdf |
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .