3-FAC25022-Art Barn IAImprvmts PLANS.pdf

PDF 13 MB Posted

Attached to
Art Barn Accessibility and Infrastructure Improvements
Solicitation number
FAC25022
Issued by
Utah

About this file

Art Barn Infrastructure and Accessibility Improvements

This construction document set comprises architectural, mechanical, and electrical plans prepared for Salt Lake City Corporation's Art Barn Infrastructure and Accessibility Improvements project located at 54 Finch Lane, Salt Lake City, Utah 84102. The project scope includes general improvements to the art exhibit gallery space with renovations to the main entry, removal of the existing ADA ramp, relocation of the ADA entrance to the north door, remodeling of a storage closet, installation of new gallery hardwood flooring, painting, new ceiling tile, new exhibit lighting, remodeling of administrative offices, new carpet installation, and modifications to electrical and mechanical systems. The work encompasses demolition of existing interior partition walls, removal of existing wood ramps and stairs, installation of new concrete ramps with ADA-compliant handrails, new door installations, new stair construction, and reconfiguration of HVAC ductwork and grilles. The project is designed by EDA Architects with Sean A. Fyfe, AIA serving as City Architect, and Resolut Group providing mechanical and electrical engineering services. The permit set of drawings was dated September 10, 2026, with final revisions completed as of September 15, 2026.

The contract documents establish comprehensive requirements for all general contractors, subcontractors, and sub-subcontractors, mandating licensure to work in the State of Utah and full compliance with federal, state, and local codes including the International Building Code, International Mechanical Code, and National Electrical Code. All mounting heights for signage, fixtures, cabinetry, handrails, and toilet accessories must meet ADA standards. The contractor is responsible for verifying all existing conditions prior to installation, protecting adjacent surfaces during demolition, coordinating work with all trades including mechanical, electrical, and structural components, and ensuring fire-rated wall and ceiling penetrations are sealed appropriately. Material specifications require copper conductors with THHN/THWN-2 insulation, minimum 3/4-inch conduit size, separate equipment grounding conductors, and proper sealing of all penetrations of fire-rated assemblies. The project requires complete coordination between architectural, mechanical, and electrical systems to avoid conflicts, with the contractor bearing responsibility for final design and layout details not explicitly shown on the diagrammatic drawings.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

SALT LAKE CITY CORPORATION

SITE ORIENTATION MAP

(SEE SHEET INDEX ON G001)

DATESEAN A. FYFE, AIA

CITY ARCHITECT

OWNER

DEPARTMENT OF

ACM DIVISION

CITY ARCHITECT - SEAN A. FYFE, AIA

CITY COUNCIL

DIST. 5

DIST. 7

DIST. 6

DIST. 4

DIST. 3

DIST. 2

DIST. 1

MAYOR

ERIKA CARLSEN

SARAH YOUNG

DAN DUGAN

CHRIS WHARTON

ALEJANDRO PUY

VICTORIA PETRO

ERIN MENDENHALL

CITY OFFICIALS

ARCHITECT

ENGINEERS

DATE DATE DATE DATE DATE DATE DATE

FACILITIES DIVISION DIRECTOR

RILEY BYRD

CONSTRUCTION DOCUMENTS

OLD SALT LAKE CITY MAIN LIBRARYOLD SALT LAKE CITY MAIN LIBRARY

RESOLUT

181 E 5600 S, Ste #200

801.530.3148 www.resolutgroup.com

Salt Lake City, UT 84107

ACM DIVISION

ARCHITECTURE & CONSTRUCTION

MANAGEMENT (ACM) DIVISION

ARCHITECTURE AND CONSTRUCTION

MANAGEMENT DIVISION (ACM)

349 SOUTH 200 EAST, SUITE 100

SALT LAKE CITY, UTAH 84111

OFFICE - 801.535.7116

ACM DIVISION

CITY ARCHITECT - SEAN A. FYFE, AIA

349 SOUTH 200 EAST, SUITE 100

SALT LAKE CITY, UTAH 84111

OFFICE - 801.535.7116

DIRECTOR OF PUBLIC SERVICES - JORGE CHAMORRO

SALT LAKE CITY CORPORATION

NATHAN JOHNSEN

ART BARN INFRASTRUCTURE AND ACCESSIBILITY

IMPROVEMENTS

54 Finch Lane, Salt Lake City, Utah 84102

JOB NO. FAC25002

09.14.26

A R

T B

A R

N

IN

F R

A S

T R

U C

T U

R E

A N

D A

C C

E S

S

IB

IL

IT

Y

IM

P

R O

V E

M E

N T

S

F in ch L an e, S al t L ak e C ity , U ta h

JO

B N

O

F A

C

SALT LAKE CITY ARTS COUNCIL-

FINCH LANE ART GALLERY

SALT LAKE CITY ARTS COUNCIL-

FINCH LANE ART GALLERY

smarjaei 10/5/2026 Review of this material is for assistance in interpreting the design concept. This action does not change the contract requirements.

Total performance, dimension, arrangement accessibility, additional necessary items, etc. are the responsibility of the contractor. Contractor must coordinate the work with all trades, select fabricating methods, and perform the work in a safe and satisfactory manner.

No Exceptions Taken Make Corrections Noted

Reviewed Rejected

DateBy

Revise & Resubmit

ENGINEERS

9 EXCHANGE PLACE, SUITE 1100,

SALT LAKE CITY, UTAH 84111

801-531-7600

WWW.EDAARCH.COM

DEPARTMENT OF PUBLIC SERVICES

CONSTRUCTION PROGRAM / PROJECTS

MANAGER

JENNIFER NAPIER-PEARCE

VISUAL ARTS PROGRAM COORDINATOR EDA ARCHITECTS

TODD OBERNDORFER JAKE HILL

AFF

ACT

ADDL

ADJ

ADMIN

ALT

ALUM

ANOD

APPROX

ARCH

AV

BLW

BD

BO

BLDG

BLT

CAB

CSWK

CIP

CLG

CTR

CL

CIR

CLR

COL

CONC

CMU

CONF

CONSTR

CD

CJ

COORD

CONT

CORR

CNTR

CSK

CUST

DBE

DEG

DEMO

DET

DIAG

DIA

DIM

DIR

DIST

DR

DBL

DWG

DF

EA

E

ELEC

EWC

ELEV

EMER

ENCL

EQ

EQUIP

EST

ETC

EXIST

EXP

EJ

EXT

EIFS

FT

FIN FLR

FEC

FIXT

FD

FURN

GA

GALV

GC

GL

GYP BD

HCP

HNDRL

HDW

HDWD

HDR

HVAC

HT

HM

HB

ABBREVIATIONS

AND

ABOVE FINISH FLOOR

ACOUSTIC CEILING TILE

ADDITIONAL

ADJACENT/ADJUSTABLE

ADMINISTRATION

ALTERNATE

ALUMINUM

ANODIZED

APPROXIMATELY

ARCHITECTURAL

AUDIO/VISUAL

BELOW

BOARD

BOTTOM OF

BUILDING

BUILT

CABINET

CASEWORK

CAST IN PLACE

CEILING

CENTER

CENTER LINE

CIRCLE

CLEAR

COLUMN

CONCRETE

CONCRETE MASONRY UNIT

CONFERENCE

CONSTRUCTION

CONSTRUCTION DOCUMENTS

CONTROL JOINT

COORDINATE

CONTINUE/ CONTINUOUS

CORRIDOR

COUNTER

COUNTERSUNK

CUSTODIAN

DECK BEARING ELEVATION

DEGREE

DEMOLITION/ DEMOLISH

DETAIL

DIAGONAL

DIAMETER

DIMENSION

DIRECTION

DISTANCE

DOOR

DOUBLE

DRAWING

DRINKING FOUNTAIN

EACH

EAST

ELECTRICAL

ELECTRICAL WATER COOLER

ELEVATION

EMERGENCY

ENCLOSURE

EQUAL

EQUIPMENT

ESTIMATE

ET CETERA

EXISTING

EXPANSION

EXPANSION JOINT

EXTERIOR

EXTERIOR INSULATION

& FINISH SYSTEM

FOOT

FINISH FLOOR

FIRE EXTINGUISHER CABINET

FIXTURE

FLOOR DRAIN

FURNITURE/ FURNISHINGS

GAUGE

GALVANIZED

GENERAL CONTRACTOR

GLASS

GYPSUM BOARD

HANDICAP

HANDRAIL

HARDWARE

HARDWOOD

HEADER

HEATING, VENTILATION,

& AIR CONDITIONING

HEIGHT

HOLLOW METAL

HOSE BIBB

ID

INFO

INSUL

INT

JAN

J-BOX

LAM

LAV

MAINT

MFR

MATL

MAX

MECH

MTL

MIN

OC

ORIG

OD

OPP

PT

PBD

PLYWD

PAF

PREF

PRELIM

PREV

PROJ

QTY

R

RLG

RM

RCP

REINF

RFI

RFP

REQ'D

REV

RD

RO

SCHED

SECT

SHT

SIM

SC

SCWD

S

SMFEC

SPEC

SQ

SF

STD

SS

STL

STOR

SD

STRUCT

SUSP CLG

TBD

TMPD

TEMP

THRES

THRU

T&G

TO

TOB

TOC

TOF

TOS

TOW

TS

TYP

UNO

UTIL

VIF

VERT

VEST

VCT

WC

WT

W W/ W/O

WD

INSIDE DIAMETER

INFORMATION

INSULATION

INTERIOR

JANITOR

JUNCTION BOX

LAMINATE

LAVATORY

MAINTENANCE

MANUFACTURER

MATERIAL

MAXIMUM

MECHANICAL

METAL

MINIMUM

ON CENTER

ORIGINAL

OUTSIDE DIAMETER

OPPOSITE

PAINT

PARTICLE BOARD

PLYWOOD

POWDER ACTUATED FASTENER

PREFERENCE

PRELIMINARY

PREVIOUS

PROJECT

QUANTITY

RADIUS

RAILING

ROOM

REFLECTED CEILING PLAN

REINFORCED

REQUEST FOR INFORMATION

REQUEST FOR PROPOSAL

REQUIRED

REVISION

ROOF DRAIN

ROUGH OPENING

SCHEDULE

SECTION

SHEET

SIMILAR

SOLID CORE

SOLID CORE WOOD DOOR

SOUTH

SUFACE MOUNTED FIRE

EXTINGUISHER CABINET

SPECIFICATIONS

SQUARE

SQUARE FEET

STANDARD

STAINLESS STEEL

STEEL

STORAGE

STORM DRAIN

STRUCTURAL

SUSPENDED CEILING

TO BE DETERMINED

TEMPERED

TEMPORARY

THRESHOLD

THROUGH

TONGUE & GROOVE

TOP OF

TOP OF BEAM

TOP OF CONCRETE

TOP OF FLOOR/ FOOTING

TOP OF SLAB

TOP OF WALL

TUBE STEEL

TYPICAL

UNLESS NOTED OTHERWISE

UTILITY

VERIFY IN FIELD

VERTICAL

VESTIBULE

VINYL COMPOSITE TILE

WATER CLOSET

WEIGHT

WEST

WITH

WITHOUT

WOOD

VICINITY MAP

PROJECT NORTH

SYMBOLS

FINISH WOOD

MASONRY WALL

WOOD STUD WALL

METAL STUD WALL

ACOUSTIC TILE

GYPSUM BOARD

CERAMIC TILE & GROUT BED

BRICK/BRICK WALL

WOOD BLOCKING

SEMI-RIGID INSULATION

RIGID INSULATION

BATT INSULATION

WOOD FRAMING

INSULATED GLASS

GLASS

SPRAY FOAM INSULATION

STEEL

CONCRETE

SAND/GROUT FILL

GRAVEL

ASPHALT PAVING

ALUMINUM

EARTH/COMPACTED

ENGINEERED/STRUCTURAL FILL

(AS INDICATED)

ROOM NAME

& NUMBER

GRID

NUMBER DETAIL

FINISH

TYPE

CEILING TYPE

& HEIGHT SIGN TYPE

SPOT ELEV. /

BENCHMARK

GLASS

TYPE

1 AG1 101a

WINDOW

TYPE

A

REVISION

MARK

KEYED NOTE

NEW/DEMOLITION

DOOR

NUMBER

WALL

TYPE

A1

ROOM

NAME

A601

1 DETAIL NUMBER

SHEET ON WHICH

THE DETAIL APPEARS

F1 C1 8'-0" S1

A

B

100'-0"

T.O. SLAB

GL

A401 A201 A301

AA

A310

B

DETAIL NUMBER

SHEET ON WHICH

THE ELEVATION APPEARS

DETAIL NUMBER

SHEET ON WHICH

THE ELEVATION APPEARS

DETAIL NUMBER

SHEET ON WHICH

THE SECTION APPEARS

DETAIL NUMBER

SHEET ON WHICH

THE SECTION APPEARS

INTERION ELEVATION BUILDING ELEVATION BUILDING SECTION WALL SECTION

FINISH LEVEL/

DATUM

EXISTING SPOT

ELEVATION

MATCHLINE &

AREA DESIGNATION

GRID LINE &

NUMBER

PLYWOOD

CONT. WEATHER BARRIER

1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES WITH THE CONSTRUCTION DOCUMENTS TO ARCHITECT PRIOR TO ANY INSTALLATION AND/OR ASSOCIATED CONSTRUCTION ACTIVITY.

2. CONSTRUCTION DAMAGE TO ANY ADJACENT SURFACES, DUE TO DEMOLITION ACTIVITIES OR NEW CONSTRUCTION, SHALL

BE PATCHED OR REPAIRED TO MATCH ADJACENT SURFACES.

3. ALL GENERAL CONTRACTORS, SUBCONTRACTORS AND SUB-SUBCONTRACTORS SHALL BE LICENSED TO WORK IN THE

STATE OF UTAH.

4. ALL WORK AND MATERIALS SHALL BE IN FULL CONFORMANCE WITH THE LATEST FEDERAL, STATE, AND LOCAL CODES, LAWS AND ORDINANCES, INCLUDING THEIR MOST RECENT REVISIONS, AMENDMENTS AND INTERPRETATIONS.

5. THE GENERAL CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ARCHITECT FOR IMMEDIATE RESOLUTION, ANY CODE VIOLATIONS OR INCORRECT CONSTRUCTION OR SAFETY PROBLEMS THAT ARE EXISTING CONDITIONS.

6. ALL DIMENSIONS SHALL BE AS INDICATED ON THE DRAWINGS OR AS CLARIFIED BY THE ARCHITECT. UNDER NO CIRCUMSTANCES SHALL DIMENSIONS BE DETERMINED BY SCALING THE DRAWINGS. BRING ANY DIMENSIONAL

DISCREPANCIES TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION.

7. ALL MOUNTING HEIGHTS OF SIGNAGE, FIXTURES, CABINETRY, HAND/ GUARDRAILS AND TOILET ACCESSORIES SHALL MEET

ADA STANDARDS.

8. ADJACENT, IN-LINE PARTITIONS OF DIFFERENT TYPES SHALL BE CONSTRUCTED SUCH THAT EXPOSED, FINISHED SURFACES

ARE FLUSH AND CONTINUOUS.

9. FLOOR PLANS INDICATE FLOOR FINISH TRANSITIONS ONLY WHERE TRANSITIONS OCCUR WITHIN ROOMS OR SPACES, UNLESS OTHERWISE NOTED.

10. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED AS PART OF THIS CONTRACT OR BY OTHERS.

11. REFER TO MECHANICAL, ELECTRICAL, AND OTHER CATEGORIES OF DRAWINGS FOR ADDITIONAL NOTES.

12. SEE SYMBOL LEGEND FOR TYPICAL GRAPHIC SYMBOLS.

13. ALL WOOD BLOCKING WITHIN WALLS SHALL BE FIRE-RETARDANT PRESSURE-TREATED LUMBER.

GENERAL NOTES

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

G001

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

NOTES, SHEET

INDEXES,

ABBREVIATIONS &

VICINTY MAP

PROJECT LOCATION

INDEX - ARCHITECTURAL DRAWINGS

SHEET # SHEET NAME

A001 SITE STAGING PLAN

AD101 MAIN FLOOR DEMOLITION PLAN

AD102 MAIN FLOOR REFLECTED CEILING DEMOLITION PLAN

A100 LEVEL 01 FLOOR PLAN

A110 MAIN LEVEL REFLECTED CEILING PLAN

A120 ROOF PLAN

A500 DETAILS

INDEX - ELECTRICAL DRAWINGS

SHEET # SHEET NAME

E001 ELECTRICAL TITLE SHEET

E002 ELECTRICAL SCHEDULES

ED111 MAIN LEVEL - DEMOLITION PLAN

EL111 MAIN LEVEL - LIGHTING PLAN

EP101 BASEMENT POWER FLOOR PLAN

EP111 MAIN LEVEL - POWER FLOOR PLAN

EP600 POWER SCHEDULES

INDEX - GENERAL DRAWINGS

SHEET # SHEET NAME

G000 TITLE SHEET

G001 NOTES, SHEET INDEXES, ABBREVIATIONS & VICINTY MAP

# REVISION DATE

1 PERMIT SET 09.10.2026

INDEX - MECHANICAL DRAWINGS...

SHEET # SHEET NAME

ME001 HVAC TITLE SHEET

MD101 MECHANICAL DEMO PLAN

M101 MECHANICAL PLAN

M501 MECHANICAL DETAILS AND SCHEDULES

W

ALK

4587.89

W

ALK

4587.73

W

ALK

4587.86

W

ALK

4587.97

TBC 4588.22

TBC4588.12

TBC4588.17

TBC4588.11

TBC4588.27

W

ALK

4588.03

D

EC TREE 2417.0W

" DIA

0.00

STEP4591.76

4589.42

4587.58

4586.31

4585.74

4586.46

4585.32

W

ALK

4582.42

W

ALK

4582.41

TBC4583.04

TBC4587.93

W

ALK

4587.41

W

ALK JO

INT

4587.15

TBC4587.56

TBC4587.36

W

ALK

4586.97

W

ALK

4586.79

TBC 4587.23

TBC 4587.03

W

ALK JO

INT

4586.61

W

ALK JO

INT

4586.01

TBC4586.42

TBC4585.64

W

ALK JO

INT

4585.25

W

ALK JO

INT

4584.82

TBC4585.21

TBC4584.45

W

ALK JO

INT

4584.07

W

ALK JO

INT

4583.02

TBC4583.44

4589.90 4588.90

4588.28

4587.95

4586.75

4585.73

4584.11

4583.21

4582.90

4582.47

4581.90

W

ALK JO

INT

4582.03

W

ALK JO

INT

4581.89

4581.97

4583.01

W

ALK JO

INT

4582.03

W

ALK JO

INT

4582.12

W

ALK

4582.21

ENTRY4582.32

ENTRY4582.37

TBC4582.95

W

ALK

4582.32

W

ALK

4582.21

TBC4582.84

TBC4582.77

W

ALK JO

INT

4582.12

W

ALK JO

INT

4582.10

W

ALK JO

INT

4582.02

W

ALK JO

INT

4582.06

W

ALK JO

INT

4583.05

STEP4584.98

STEP 4585.05

W

ALK

4584.47

W

ALK

4583.17

W

ALK

4584.06

D

EC TREE 20" DIA

4585.43

4586.50

4585.49

TBC4584.88

W

ALK

4584.57

TBC4585.33

W

ALK JO

INT

4584.98

W

ALK

4585.26

TBC4585.58

TBC4585.83

W

ALK JO

INT

4585.51

W

ALK JO

INT

4586.02

TBC 4586.35

LIG

HT PO

LE

4585.80

TBC4586.82

TBC4587.00

W

ALK JO

INT

4586.53

W

ALK

4586.65

W

ALK

4586.76

TBC4587.10

TBC4587.20

W

ALK

4586.87

W

ALK

4586.98

TBC4587.33

TBC4587.80

W

ALK

4587.45

TBC4587.52

W

ALK JO

INT

4587.21

TBC4587.94

STEP4587.94

W

ALK

4587.56

W

ALK

4587.56

STEP4587.93

TBC4587.85

TBC4587.94

W

ALK

4587.55

W

ALK

4587.52

STEP4588.07STEP4588.09

W

ALK

4587.52

JO

INT/STO

NE CO

NC

4587.68

JO

INT/STO

NE CO

NC

4587.70

TBC 4588.03

4586.72

4587.26

W

ALK

4587.82

TBC4588.10

TBC4588.21

TBC4588.51

W

ALK

4588.11

JO

INT/STO

NE CO

NC

4587.87

JO

INT/STO

NE CO

NC

4587.83

W

ALK

4588.21

TBC4588.60

STEP4588.80

STEP 4588.85

TBC4588.64

TBC4588.65

W

ALK JO

INT

4588.29

W

ALK JO

INT

4588.19

W

ALK JO

INT

4588.71

W

ALK JO

INT

4588.64

TBC4589.57

W

ALK JO

INT

4589.26

W

ALK JO

INT

4589.13

TBC4589.50

W

ALK

4589.62

TBC4589.94

TBC4590.14

JO

INT/STO

NE CO

NC

4589.87

W

ALK

4589.93

TBC 4590.26

TBC4590.32

W

ALK

4590.02

W

ALK

4590.18

TBC4590.59

TBC4590.24

JO

INT/STO

NE CO

NC

4589.92

W

ALK

4590.02

TBC4590.28

TBC4590.33

JO

INT/STO

NE CO

NC

4590.02

W

ALK

4590.23

TBC4590.55

W

ALK

4590.46

TBC4590.86

TBC4590.99

W

ALK JO

INT

4592.83

W

ALK JO

INT

4590.66

TBC4591.07

W

ALK

4592.82 W

ALK

4592.81

W

ALK

4592.85

TBC4592.94

STEP4591.69

LIG

HT PO

LE

4591.83

W

ALK JO

INT

4581.85

W

ALK

4584.63

TBC 4591.29

W

ALK

4590.97

W

ALK

4590.83

TBC4591.26

TBC4591.37

W

ALK

4590.99

W

ALK

4591.10

TBC4591.49

TBC4591.60

W

ALK JO

INT

4591.20

W

ALK JO

INT

4591.24

TBC4591.56

4590.28

W

ALK

4591.36 JO

INT/STO

NE CO

NC

4591.40

W

ALK

4591.33

TBC4591.80

TBC4591.93

W

ALK JO

INT

4591.31

W

ALK

4592.25

TBC4592.54

TBC4592.62

TBC4592.95TBC 4593.18

W

ALK

4592.85

TBC 4592.94

TBC 4592.96

TBC4592.80

W

ALK JO

INT

4592.55

TBC4592.57

W

ALK

4592.31

W

ALK

4592.29

TBC4592.56

TBC 4592.61 W

ALK

4592.36

W

ALK JO

INT

4592.32

4592.62

JO

INT/STO

NE CO

NC

4591.48

JO

INT/STO

NE CO

NC

4591.32

TBC4592.01

W

ALK

4591.43

W

ALK JO

INT

4592.65

4593.10

W

ALK JO

INT

4592.76

W

ALK JO

INT

4592.79

TBC4593.29

W

ALK JO

INT

4592.93

W

ALK JO

INT

4593.51

TBC4593.83

W

ALK

4592.75

TBC 4593.16

TBC4593.49

W

ALK

4593.18

W

ALK

4593.53

TBC4593.78

TBC4594.04

W

ALK

4593.83

W

ALK

4593.94

TBC4594.14

TBC4594.35

W

ALK

4594.33

W

ALK

4594.22

TBC4594.30

TBC4594.38

W

ALK

4594.42

W

ALK

4594.43

TBC4594.42

TBC4594.43

TBC4594.42

4593.95

4593.44

TBC4594.50

TBC4594.49

TBC4594.43

W

ALK

4594.42

W

ALK

4594.36

W

ALK

4594.43

W

ALK

4594.44

W

ALK

4594.43

W P1

4594.16

OS

R C

RC3

RC3

J J

J

RC2

RC2

OS OS

O S

F

J

S

S

SOUTH UNIVERSITY STREET

EXISTING ADA PARKING STALL TO

REMAIN, MAINTAIN ACCESS AND

USE DURING CONSTRUCTION.

PARKING

TENNIS COURT

ADA ENTRANCE.

ART BARN

EXISTING EXTERIOR RAMP TO

REMAIN.

SCOPE OF WORK

AREA - CUT

EXISTING RAILING,

GRIND CONCRETE.

SCOPE OF WORK AREA -

EXTERIOR WALK.

CONTRACTOR PARKING

MATERIAL STAGING

REFUGE CONTAINER.

NOT IN THE SCOPE

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

A001

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

SITE STAGING PLAN

1/16" = 1'-0"

SITE STAGING PLAN

PROJECT NORTH

# REVISION DATE

1 PERMIT SET 09.10.2026

UP

GENERAL DEMOLITION NOTES

1. FIELD-VERIFY ALL EXISTING CONDITIONS.

2. PROTECT ADJACENT SURFACES & MATERIALS TO REMAIN DURING DEMOLITION. REPAIR/REPLACE

ALL DAMAGED SURFACES/MATERIALS AS REQUIRED TO MATCH EXISTING.

3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF DEMOLITION

WORK.

4. DASHED LINES INDICATE EXISTING CONSTRUCTION TO BE REMOVED, UNLESS NOTED OTHERWISE.

5. PROTECT ALL EXISTING CONSTRUCTION, FINISHES, STRUCTURE, EQUIPMENT, AND BUILDING

SYSTEMS TO REMAIN.

6. REMOVE EXISTING DOORS, FRAMES, HARDWARE, PARTITIONS, FLOOR FINISHES, BASE, CEILING

FINISHES, AND RELATED ITEMS AS REQUIRED FOR NEW WORK.

7. PATCH, REPAIR, AND PREPARE ALL EXISTING WALL, FLOOR, AND CEILING SURFACES AFFECTED BY

DEMOLITION TO RECEIVE NEW FINISHES.

8. COORDINATE DEMOLITION WORK WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL,

ELECTRICAL, AND PLUMBING DRAWINGS.

9. DO NOT REMOVE STRUCTURAL OR LOAD-BEARING ELEMENTS UNLESS SPECIFICALLY NOTED AND

APPROVED BY STRUCTURAL ENGINEER.

10. CONTRACTOR SHALL MAINTAIN SAFE EGRESS AND PROVIDE TEMPORARY PROTECTION, DUST

CONTROL, AND BARRIERS DURING DEMOLITION.

11. REMOVE AND DISPOSE OF DEMOLISHED MATERIALS IN ACCORDANCE WITH LOCAL CODES AND

REGULATIONS.

12. EXISTING DIMENSIONS AND CONDITIONS SHOWN ARE APPROXIMATE. VERIFY IN FIELD PRIOR TO

CONSTRUCTION.

DEMOLITION PLAN LEGEND

EXISTING ELEMENT TO REMAIN

EXISTING ELEMENT TO BE DEMOLISHED

AREA NOT IN SCOPE

EXISTING WOOD FLOOR TO BE REMOVED

EXISTING CARPET FLOOR TO BE REMOVED

OFFICE

CONFERENCE ROOM

D1D3

D9

D2

D5D5

D5

D6

D6

D7

D8

D10 D10

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11

D11 D11

D11

D11

D11

D11D11

D11

D11

D9

D9

OFFICE

OFFICE

PRINT ROOM

RECEPTION

ART GALLERY

ART GALLERY

ENTRANCE

D12

D9

D9

D13

D14 D14D14

D14

D5

D15

GRIND CURB FLUSH WITH

CONCRETE SLAB

REMOVE THREE POST, CUT TOP RAIL

BACK TO FOURTH POST, GRIND SMOOTH

D16

D17

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

AD101

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

MAIN FLOOR

DEMOLITION PLAN

KEYED NOTES

D1 REMOVE EXISTING WOOD FLOOR FINISH AND BASE AS REQUIRED FOR NEW WORK.

D2 REMOVE EXISTING CARPET, AND RELATED FLOOR FINISHES THROUGHOUT AREA OF WORK.

D3 DEMOLISH EXISTING INTERIOR PARTITION WALL BETWEEN CONFERENCE ROOM AND DIRECTOR’S OFFICE TO

CREATE ONE COMBINED SPACE.

D5 REMOVE EXISTING WOOD RAMP, STEEL RAILING, WOOD BASE, CURBING, AND ASSOCIATED INTERIOR

ELEMENTS AS REQUIRED.

D6 REMOVE EXISTING STAIR AS REQUIRED FOR NEW STAIR LAYOUT. PROTECT EXISTING STRUCTURE TO REMAIN.

D7 REMOVE EXISTING SLIDING VINYL-FRAMED GLASS DOOR, FRAME, TRACK, AND ASSOCIATED HARDWARE.

D8 MODIFY EXISTING SUPPLY AIR DUCT AT MAIN ENTRANCE AS REQUIRED FOR NEW STAIR LAYOUT.

COORDINATE WITH MECHANICAL.

D9 DEMOLISH EXISTING INTERIOR PARTITION WALL AS INDICATED.

D10 REMOVE EXISTING TRANSITION STRIPS AS INDICATED.

D11 REMOVE EXISTING WOOD BASE AS INDICATED.

D12 MOVE FIRE ALARM DEVICE AND DEMO J-BOX.

D13 REMOVE EXISTING FLOOR SHEATHING AT CLOSET, PROVIDE CLEATS AS NECESSARY TO SUPPORT NEW

FLOOR MATERIAL.

D14 REMOVE THREE POSTS STARTING AT THE SOUTH END OF RAILING, REMOVE HANDRAIL PORTION BACK TO

FOURTH POST FROM SOUTH END, GRIND SMOOTH. GRIND CONCRETE CURB FLUSH WITH CONCRETE SLAB.

D15 DEMO OPENING TO ACOMODATE 3'-0" X 6'-8" HOLLOW CORE WOOD DOOR WITH JAMB WOOD PAINTED AND

TRIM TO WOOD PAINTED.

D16 DEMO CARPET.

D17 DEMOLISH EXISTING DOOR HEADER, PREPARE FOR NEW HEADER.

1/4" = 1'-0"

MAIN LEVEL DEMOLITION FLOOR PLAN

PROJECT NORTH

J J J

A

B

2 C

D

E

F G

H

J

A

B

2 C

D

E

F G

H

J

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

AD102

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

MAIN FLOOR

REFLECTED CEILING

DEMOLITION PLAN

1/4" = 1'-0"

LEVEL 1 RCP DEMOLITION PLAN

# REVISION DATE

1 PERMIT SET 09.10.2026

DEMOLISH DIRECT APPLIED

ACOUSTICAL CEILING TILES AT

OFFICE, MEETING ROOM AND

BOTH GALLERY SPACES

MODIFY HVAC DEVICES AND

DUCTWORK PER MECHANICAL

DRAWINGS

F

1. FIELD-VERIFY ALL EXISTING CONDITIONS.

2. REFER TO SHEET G001 FOR GENERAL NOTES.

3. REFER TO SHEET G002 FOR RATED WALL LOCATIONS.

4. SEALANT IS REQUIRED AROUND ALL FRAMES,

OPENINGS, EXPANSION & CONTROL JOINTS, AND

BETWEEN DISSIMILAR MATERIALS, INDICATED OR

OTHERWISE. USE SEALANTS AS SCHEDULED, OR AS

RECOMMENDED BY MANUFACTURER FOR

CONDITIONS. CONSULT ARCHITECT WHERE MORE

THAN ONE PRODUCT MAY BE SUITABLE, AND FOR

COLOR SELECTION.

FLOOR PLAN LEGEND

GENERAL FLOOR PLAN NOTES

WOOD STUD WALL

2X4 WOOD STUDS,

3" SOUND BATT INSULATION,

5/8" TYPE X GYPSUM BOARD BOTH SIDES,

PAINTED.

EXISTING WALL TO REMAIN

ART GALLERY

P1

F2

B2

ROOM NAME

ROOM NUMBER

WALL FINISH

FLOOR FINISH

WALL BASE

1' -7

A500

A50011

A500

OFFICE

P1

F1

B1

OFFICE

P1

F1

B1

OFFICE

P1

F1

B1

PHONE ROOM

P1

F1

B1

HALLWAY

P1

F1

B1

RECEPTION

P1

F1

B1

ART GALLERY

P1

F2

B2

ART GALLERY

P1

F2

B2

5.8%

1.7%

WIRELESS DOOR OPERATOR

ON 48" HIGH STAINLESS

STEEL PEDESTAL

NEW HANDRAILS, BOTH SIDES OF NEW RAMP.

REFER TO RAILING ELEVATION

NEW 4" CONCRETE RAMP, OVER 4" COMPACTED FREE DRAINING

GRANULAR MATERIAL OVER COMPACTED SUB-BASE.

PROVIDE 2% MAXIMUM CROSS SLOPE ON RAMP.

NEW DOOR AND FRAME IN

EXISTING WALL

NEW WOOD FLOORING AND NEW

THRESHOLD AT EXTERIOR DOOR

6'-0"

125 124

+/- 9'-8"

A500

NEW WOOD FLOOR, MATCH EXISTING

S1

S2

12"X18" ADA SIGN

6"X9"

ADA SIGN

6"X9" ADA SIGN

EXISTING DOOR

TO REMAIN

NEW WOOD BENCH

RUBBER TRANSITION

STRIP, CARPET TO WOOD

FLOOR, FIELD VERIFY

CONDITION BEFORE

ORDERING.

A500

S3

5'-0"

PROVIDE KEY SWITCH TO

DISABLE DOOR OPENER

NEW FLOOR

GRILLE

NEW FLOOR

GRILLE

RESTROOM

NOT IN

SCOPE

KITCHEN

NOT IN

SCOPE

STORAGE

NOT IN

SCOPE

DOWN

ENTRANCE

ENTRANCE

NEW CONCRETE LANDING

2% MAX SLOPE

EXISTING CONCRETE WALK TO REMAIN

EXISTING CONCRETE

WALK TO REMAIN

EXISTING

ACCESSIBLE

PARKING STALL

PROVIDE NEW FULL

HEIGHT STUD WALL, ALIGN

WITH EXISTING WALL.

A500

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

A100

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

LEVEL 01 FLOOR

PLAN

PROJECT NORTH

FINISH SCHEDULE

RM # ROOM NAME FLOOR BASE

WALLS

CEILING COMMENTSNORTH SOUTH EAST WEST

122 OFFICE F1 B1 P1 P1 P1 P1 C3

123 OFFICE F1 B1 P1 P1 P1 P1 C3

124 OFFICE F1 B1 P1 P1 P1 P1 C4

125 PHONE ROOM F1 B1 P1 P1 P1 P1 C3

126 HALLWAY F1 B1 P1 P1 P1 P1 C3

127 RECEPTION F1 B1 P1 P1 P1 P1 C3

129 ART GALLERY F2 B2 P1 P1 P1 P1 C1

130 ART GALLERY F2 B2 P1 P1 P1 P1 C1,C4

FINISH LEGEND

MARK MATERIAL MANUFACTURER MODEL

PATTERN/N

UMBER COLOR FINISH SIZE COMMENTS

FLOOR

F1 CARPET TILE

F2 HARD WOOD FLOORING NATURAL STAINED 2.5" PROFILE WOOD FLOOR, WHITE OAK, PLAIN/ FLAT SLICE, 2.5" WIDE

PLANK, FINISH TO MATCH EXISTING

BASE

B1 RUBBER WALL BASE 4" COVED

B2 WOOD WALL BASE PAINT PAINT GRADE, PROFILE TO MATCH EXISTING

PAINT

P1 PAINT WHITE

P2 PAINT BLACK BLACK, CEILINGS IN GALLERY SPACES, DIRECT APPLIED

ACOUSTIC TILES, PAINTED BLACK

CEILING

C1 EXISTING ACOUSTIC CEILING TILE BLACK PRE FINISHED OR

PAINTED

24" x 24" DIRECT APPLIED (GLUED)

C2 EXISTING GYP. BOARD PAINTED

C3 EXISTING ACOUSTIC CEILING TILE P1 PAINTED

C4 NEW ACOUSTIC CEILING PANEL

SYSTEM

WHITE 24" x 24"

MISCELLANEOUS

PL1 PLASTIC LAMINATE FRONT ENTRY CASEWORK

WV1 WOOD VENEER FRONT ENTRY CASEWORK

1/4" = 1'-0"

MAIN LEVEL PLAN

DOOR SCHEDULE

ROOM

NO. ROOM NAME WIDTH HEIGHT T

H

IC

K

N E

S

S DOOR FRAME

COMMENTSTYPE MATERIAL FINISH MATERIAL FINISH

124 OFFICE 124 3' - 0" 6' - 8" 1 3/4" D1 WOOD PAINTED WOOD PAINTED EXISTING DOOR

125 PHONE ROOM 125 3' - 0" 6' - 8" 1 3/4" D1 WOOD PAINTED WOOD PAINTED NEW DOOR. DEATAIL 10/A500

127 RECEPTION 127 3' - 0" 6' - 8" 1 3/4" D1 WOOD PAINTED WOOD PAINTED EXISTING DOOR

129 ART GALLERY 129 3' - 0" 6' - 8" 1 3/4" D1 METAL PAINTED WOOD PAINTED NEW DOOR. DOOR OPENER, EXIT DEVICE, KEY SWITCH. DETAIL 9/A500

C3 8' - 8"

C3 10' - 0"

C2 9' - 3"

C4 9' - 0"

MODIFY DUCTWORK AND AIR

DEVICES TO ACCOMMODATE

NEW FULL HEIGHT WALL

EXISTING TO REMAIN

EXISTING TO REMAIN

NEW SUSPENDED ACOUSTIC

CEILING PANEL SYSTEM

9'-0"

C1 9' - 0"

C1 9' - 0"

COORDINATE MECHANICAL

DUCT WITH ELECTRICAL

(LIGHT)

GENERAL CEILING NOTES

1. REFER TO MECHANICAL & ELECTRICAL DRAWINGS

FOR ACTUAL FIXTURE/DEVICE INFORMATION. SHOWN

HERE FOR SPECIFIC DIMENSIONS AND GENERAL

LAYOUT COORDINATION.

2. COORDINATE THE LAYOUT OF CEILING SUSPENSION

TO ACHIEVE THE LOCATIONS OF ALL ITEMS TO BE

INSTALLED IN THE CEILING.

3. LAY-IN GRID CEILINGS ARE SHOWN FOR INTENT. LAY

OUT ACOUSTICAL TILES SYMETRICALLY WITHIN

INDIVIDUAL SPACES.

4. FIRE SPRINKLER SYSTEM SHALL BE FULLY

COORDINATED WITH ALL TRADES PRIOR TO

INSTALLATION TO ENSURE ALL SYSTEM ARE

INSTALLED AS TIGHT TO THE STRUCTURE ABOVE AS

POSSIBLE. HEADS SHALL BE INSTALLED

SYMETRICALLY WITHIN INDIVIDUAL SPACES.

5. LOCATE SMOKE ALARMS, SPRINKLER HEADS, AND

ALL OTHER CEILING-MOUNTED DEVICES AT THE

CENTER OF CEILING TILES / CLOUDS.

6. ALL OPEN-TO-STRUCTURE CEILINGS SHALL BE

PAINTED, INCLUDING ALL EXPOSED DUCTWORK,

PIPING, CONDUIT, ETC.

7. ALL SUSPENDED ITEMS SHALL BE SEISMICALLY

BRACED, AS REQUIRED BY CODE.

CEILING LEGEND

C1, EXISTING ACOUSTIC

CEILING TILE

C3, EXISTING ACOUSTIC

CEILING TILE

C2, EXISTING GYP. BOARD

C4, NEW ACOUSTIC CEILING

PANEL SYSTEM

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

A110

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

MAIN LEVEL

REFLECTED CEILING

PLAN

1/4" = 1'-0"

MAIN LEVEL REFLECTED CEILING PLAN

PROJECT NORTH

PATCH 3. PROVIDE FLASHING AT THE

NEW DUCT WORK PENETRATION. REFER

TO MECHANICAL.

EXISTING SINGLE PLY

MEMBRANE ROOF

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

A120

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

ROOF PLAN

# REVISION DATE

1 PERMIT SET 09.10.2026

1/4" = 1'-0"

ROOF PLAN

BEBE

A500 2

ALL HANDRAILS TO BE 1 1/4" I.D. STEEL PIPE WELD AND GRIND

SMOOTHLY JOINTS. PROVIDE END SUPPORTS, BRACKETS, POST

ANCHORAGE SOCKET ESCUTCHEON PLATES. MOUNTING HT.

SHALL BE 34" @ NOSING. PAINT ALL MEMEBERS.

18" HEIGHT BENCH, STRATA 5 FT. BACKLESS

BENCH, WWW.COUNTRYCASUALTEAK.COM OR

EQUAL., FIELD FINISH.

A500

1'-5"

NEW FLOOR GRILLE

NEW FLOOR

GRILLE

PROVIDE WOOD LEDGERS

AND NEW SUBFLOOR

WHERE FAILING AT CLOSET

EXTEND NEW RAILING

TO EXISTING WALL

CARPET TO REMAIN ON

STAIRS GOING UP

NEW HARDWOOD FLOORING

AT ENTRY AND STAIRS

NEW FULL HEIGHT 2x4 WOOD

STUD WALL WITH GYPSUM

BOARD, PAINTED ON ENTRY SIDE

NEW BUILT-IN CABINET

FLOOR FRAMING AT EXISTING ENTRY

AREA TO REMAIN COORDINATE WITH

DEMO OF EXISTING INTERIOR STAIRS

BUILD NEW STAIRS AND LANDING

1'-2 1/2" 1'-7"

5'-0"

5'-11"

1' -1

1"

A500

EXISTING GLAZING TO REMAIN

NEW DOOR

WOOD BASE, PAINTED

PLASTIC LAMINATE DOOR &

DRAWER FRONT, (PL1) SELF

EDGE (TYP)

COUNTERTOP; PLASTIC

LAMINATE (PL2), WITH

VINYL EDGE BANDING

3"

WHITE MELAMINE INTERIOR FINISH

DOUG MOCKETT 4" TAB PULL

CORK BOARD, FROM

COUNTERTOP TO CEILING

BLOCKING AS

REQUIRED, TYP.

1'-6"

CEILING

DRAWERS

LEVEL 01

100' - 0"

1/4" THICK, TRIM-LESS AND SEAMLESS

FORBO LINOLEUM/ CORK BULLETIN

BOARD OR EQUAL. MIN CLASS B FINISH

RATING PER ASTM E 84. INSTALL ABOVE

COUNTER TO CEILING. ADHERE TO WALL

PER MANUFACTURER'S WRITTEN

INSTRUCTIONS. COLOR TO BE SELECTED

FROM MANUFACTURER'S STANDARD

COLORS.

LOCKING PLASTIC LAMINATE CUBBY

FOR MAIL SLOT, FIELD COORDINATE

SIZE

NEW CASEWORK, BASE CABINET AND

COUNTERTOP WITH (8) DRAWERS

FLOOR LEVEL AT ENTRY

LEVEL 01

100' - 0"

12" MINFIELD VERIFY12" MIN

NEW HANDRAILS, BOTH SIDES OF NEW RAMP.

36" HIGH 1 1/4" STANDARD STEEL PIPE

HANDRAIL WITH BOTTOM RAIL SPACED ABOVE

THE RAMP SURFACE THAT PREVENTS THE

PASSAGE OF A 4-INCH SPHERE .

GALVANIZED AND PAINTED

PROVIDE HANDRAIL EXTENSIONS

ANCHOR SLEEVES INTO NEW WALK SURFACE

THICKEN CONCRETE TO PROVIDE COVERAGE

PROVIDE SURFACE MOUNTED BASE PLATE WHERE

POSTS ANCHOR TO EXISTING CONCRETE

EXISTING WINDOW

0.63" PREFINISHED ALUMINUM

BRAKE METAL, FULL HEIGHT,

BOTH SIDES, FIELD VERIFY AND

INSTALL TO ACCOMMODATE

WINDOW HEAD

NEW FULL HEIGHT STUD WALL,

FIELD VERIFY AND INSTALL TO

ACCOMMODATE WINDOW

HEAD

NEW CARPET TILES

EXISTING CARPET ON STAIR

RISER, TO REMAIN

CUT CARPET AT TOP NOSING

WHERE NEW CARPET TILE IS

SCHEDULED

ROPPE #207 VINYL STAIR NOSING

ACCESSIBLE

ENTRANCE

6"

ACCESSIBLE

ENTRANCE

1'-0"

1' -6

M A

X

1/

NEW CARPET TILE

HARD WOOD

TRANSITION STRIP

NEW HARD WOOD FLOOR

ACCESSIBLE

ENTRANCE

6"

3 1/2"

/2

(4) 1/2" DIA X 3" LAG BOLTS.

1 1/4" STANDARD PIPE POSTS &

RAILING WELD TO PLATE W/ 1/4"

FILLET WELD.

3/8" THICK BASE PLATE

GRIND ALL EDGES SMOOTH,

PAINT.

PAINT ALL

COMPONENTS

WOOD DOOR CASING

AND TRIM, PROFILE TO

MATCH EXISTING,

PAINTED

PROVIDE NEW 2X6

HEADER OVER DOOR

INSULATED METAL DOOR

DRIP

1X4 CEDAR. PAINT TO MATCH EXISTING.

PREFINISHED METAL DRIP FLASHING.

NEW SHEATHING.

WOOD SHINGLES. REPLACE, AS

REQUIRED, PROFILE AND PAINT TO

MATCH EXISTING.

NEW HEADERS. (3) 2x8 MINIMUM.

PATCH GYPSUM BOARD AS

REQUIRED TO INSTALL NEW DOOR

AND HEADER.

NEW PAINTED WOOD TRIM AND

CASING, PROFILE TO MATCH

EXISTING.

11" E Q

M A

X

E Q

3/4" NEW HARDWOOD

FLOORING STEPS.

MATCH EXISTING

HEIGHT.

PLASTIC LAMINATE

RISERS ON MDF

3/4" PLYWOOD

SUB-FLOOR

NEW HARDWOOD FLOORING ON

STAIR TREADS AND FLOOR

AREAS

11"

11"

A500

A500

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

AP

JH

PROJECT NUMBER

P M

A500

DD MONTH YYYY

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

DETAILS

PROJECT NORTH

1/2" = 1'-0"

MAIN LEVEL PLAN

1/2" = 1'-0"

PHONE ROOM DOOR ELEVATION

3/4" = 1'-0"

ENTRANCE CABINET SECTION

1/2" = 1'-0"

ENTRANCE CABINET ELEVATION

1/2" = 1'-0"

RAMP HANDRAIL ELEVATION

1 1/2" = 1'-0"

WALL TO WINDOW CONECTION

6" = 1'-0"

STAIR NOSING DETAIL

6" = 1'-0" S1

ACCESSIBLE ENTRANCE

3" = 1'-0" S2

ACCESSIBLE GUIDE GUIDE

6" = 1'-0"

FLOOR TRANSITION DETAIL

6" = 1'-0" S3

ENTRANCE ACCESSIBLE GUIDE

6" = 1'-0"

STAIR POST BASE PLATE DETAIL

3" = 1'-0"

PHONE ROOM HEAD (JAM-SIMILAR) DETAIL

3" = 1'-0"

HEAD-JAMB SIMILAR

1 1/2" = 1'-0"

ENTRANCE STAIR DETAILS

# REVISION DATE

1 PERMIT SET 09.10.2026

PROVIDE PREMANUFACTURED ALUMINUM SIGNS

MOUNT TO BUILDING WHERE SHOWN ON DRAWINGS.

B

M

D

S

S

M

S

S

M

CO2

CO2

H2

HZG

NO2

O2

SYMBOL DESCRIPTION

MECHANICAL PIPING SYMBOLS LEGEND

CHWR

CHWS

GCHWR

GCHWS

CD

CWR

CWS

GHWR

GHWS

GWR

GWS

HWR

HWS

NER

NES

G

LP

RFL

RFG

RFD

LPS

LPCR

PC

HPS

HPCR

CHILLED WATER RETURN

CHILLED-WATER SUPPLY

GLYCOL INDIRECT COOLING RETURN

GLYCOL INDIRECT COOLING SUPPLY

CONDENSATE DRAIN

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

GLYCOL HEATING WATER RETURN

GLYCOL HEATING WATER SUPPLY

GROUND LOOP WATER RETURN

GROUND LOOP WATER SUPPLY

HOT WATER RETURN

HOT WATER SUPPLY

NET ENERGY LOOP RETURN

NET ENERGY LOOP SUPPLY

NATURAL GAS

LIQUID PROPANE

REFRIGERANT LIQUID

REFRIGERANT GAS

REFRIGERANT DISCHARGE

LOW PRESSURE STEAM

CONDENSATE RETURN

(LOW PRESSURE)

PUMPED CONDENSATE

HIGH PRESSURE STEAM

CONDENSATE RETURN

(HIGH PRESSURE)

PIPE RISE / PIPE DROP

BRANCH CONNECTION BELOW / TOP

PIPE TEE / PIPE 90° ELBOW

PIPE FLOW ARROW INDICATES

DIRECTION OF FLOW

PIPE CAP

SQUARE CEILING DIFFUSER / RECT.

DUCT CONNECTION.

14"Ø/24x24

500RG-2

PLR

14"Ø/24x24

RG-2

12"x12"/24x24

100EG-1

ROUND CEILING DIFFUSER

8"Ø/2s/4'-0"L

LD-100 200

PLENUM RETURN

SIDEWALL SUPPLY GRILLE

LINEAR SLOT DIFFUSER

PLENUM RETURN

CEILING RETURN

CEILING RETURN WITH SOUND BOOT

CEILING EXHAUST

RECT. DUCT CONNECTION.

RTU-X

PLR

22"x22"/24x24

RG-15

VAV BOX

VAV-X

ROOFTOP UNIT

INLINE PUMP

HWP-X

INLINE FAN

OR

EF-XX

WEF-X

CEILING EXHAUST FAN

4 WAY BLOW

PATTERN

3 WAY BLOW

PATTERN

2 WAY BLOW

PATTERN

1 WAY BLOW

PATTERN

10"x10"/24x24

250CD-2

10"Ø/24x24

250CD-2

SQUARE CEILING DIFFUSER / ROUND.

DUCT CONNECTION.

DUCTED RETURN SHOWS CFM

6"Ø/24x24

100EG-1

CEILING EXHAUST

ROUND DUCT CONNECTION.

16"x16"/16x16

SWS-1 500

AIRFLOW

NECK SIZE/ SLOT(S)/ ACTIVE LENGTH

6"Ø/24

100CD-9

SYMBOL DESCRIPTION

CONSTRUCTION DOCUMENT SYMBOLS LEGEND

AIR TERMINALS & CALLOUTS

EQUIPMENT & CALLOUTS

16"x16"/16x16

SWR-1 500

SIDEWALL RETURN GRILLE

ARROW INDICATES

DIRECTION OF AIRFLOW

ARROW INDICATES

DIRECTION OF AIRFLOW

SYMBOL DESCRIPTION

HVAC DAMPER SYMBOLS LEGEND

MANUAL DAMPER

MOTORIZED (ATC) DAMPER

BACKDRAFT DAMPER

SMOKE DAMPER

FIRE DAMPER

COMB. FIRE/ SMOKE DAMPER

TAG

MD

ATC

BD

SD

FD

FSD

24"x12"

24"/12" FO

18"Ø

FLUE

C/A

SA

SA

VA

OA

TA

RA

RLA

EA

GEA

LH

(E)

SC

DE

HVAC DUCT SYMBOLS LEGEND

SYMBOL DESCRIPTION

EXISTING DUCT TO REMAIN

OVAL DUCT SIZE (WIDTH / HEIGHT)

(CLEAR INSIDE DIMENSION) WIDTH

INDICATES PLAN SIZE

SQ. DUCT SIZE (WIDTH X HEIGHT)

(CLEAR INSIDE DIMENSION) WIDTH

INDICATES PLAN SIZE

RECT. SUPPLY DUCT RISE / DROP

ROUND DUCT SIZE (DIAMETER)

(CLEAR INSIDE DIMENSION)

DUCT TO BE DEMOLISHED

ROUND SUPPLY DUCT RISE / DROP

RECT. RETURN DUCT RISE / DROP

ROUND RETURN DUCT RISE / DROP

RECT. EXHAUST DUCT RISE / DROP

ROUND EXHAUST DUCT RISE / DROP

SUPPLY AIR - LOW PRESSURE

SUPPLY AIR - MEDIUM PRESSURE

VENTILATION AIR

OUTDOOR AIR

RETURN AIR

TRANSFER AIR

RELIEF AIR

GENERAL EXHAUST AIR

GREASE EXHAUST DUCT

LABORATORY HOOD

FLUE GAS VENT

COMBUSTION AIR

UNDER FLOOR DUCT

SAWDUST COLLECTION

DRYER EXHAUST

AIRFLOW

CATALOG THROW PERFORMANCE

NECK SIZE / MODULE SIZE

EQUIPMENT BY OTHERS

(REFER TO OTHER DISCIPLINES)

EXISTING TO REMAIN

EQUIPMENT

TYPE (SEE SCHEDULE)

MAX NC RATING

DESIGN AIRFLOW RATE

DESIGN WATER FLOW

OPERATING WEIGHT

HEATING CAPACITY

NOMINAL COOLING CAPACITY

EXISTING RELOCATED

EQUIPMENT

BOTTOM OF EQUIPMENT HEIGHT

NECK SIZE

AIRFLOW

AIRFLOW

MOUNTING ELEVATION (CENTERLINE)

NOMINAL DUCT SIZE

TYPE COUNT FOR SPACE

UNIT IDENTITY

GAS SUPPLY INPUT RATE

THROW PATTERN

(E)AHU-2

RTU-1

10.0 ton

RTU-1

180000 Btu/h

180 CFH

3.7 GPM

VAV-1-2

(R)AHU-3

EF-1

500 CFM

AC-1

7'-0" AFF:

10"Ø/24x24

H6/9/1729

CD-11 500

ET-1

379 lb

10"Ø/24x24

CD-11 500

TYP. X 4

10"Ø/24x24

CD-11 500

AFF:8'-0"

SYMBOL DESCRIPTION

ENGINERING SYMBOLS LEGEND

EQUIPMENT & CALLOUTS

AIR TERMINALS & CALLOUTS

RW

20"x12" 14"Ø

20"x20" 14"x14"

45° 45°

SYMBOL DESCRIPTION

HVAC FITTING SYMBOLS LEGEND

ROUND DUCT ELBOW R/W = 1.5

RECTANGULAR DUCT

RADIUS ELBOW

RECTANGULAR DUCT MITERED

ELBOW WITH TURNING VANES

HARD DUCT DIFFUSER CONNECTION

FLEX DUCT DIFFUSER CONNECTION

HIGH EFFECIENCY TAKE-OFF

WITH DAMPER / WITHOUT DAMPER

FLEXIBLE DUCT CONNECTION

RECT. TO ROUND DUCT TRANSITION

RECT. TO RECT. DUCT TRANSITION

SHUTOFF

BAL

BFV

CHECK

CHECK

CIRC

GATE

GLOBE

LOCK

PRV

QUICK

STRAIN

M-CNTRL

3-WAY CNTRL

GAS-CNTRL

PLUG

GAS COCK

REG

BALL VALVE

BALANCING VALVE

BUTTERFLY VALVE

CHECK VALVE

ALTERNATE CHECK VALVE

CIRCUIT SETTER

GATE VALVE

GLOBE VALVE

LOCKED SHIELD VALVE

PRESSURE REDUCING VALVE

QUICK OPENING VALVE

FLUID STRAINER

ELEC. CONTROL VALVE

3-WAY ELEC. VALVE

EMERGENCY GAS SHUTOFF

PLUG VALVE

GAS SHUTOFF COCK

GAS REGULATOR

FLUID CONTROL SYMBOLS LEGEND

SYMBOL DESCRIPTION

CONTINUATION SYMBOL

POINT WHERE NEW CONNECTS TO EXISTING

AREA BEING DEMOLISHED

AREA NOT IN CONTRACT

POINT WHERE EXISTING IS TO BE DEMOLISHED

GENERAL LEGEND

SYMBOL DESCRIPTION

KEYNOTE

ROOM NAME & NUMBER

DIAGRAM TAG

MATCH LINE TAG

ROOM

SECTION TAG. HATCHED AREA INDICATES VIEW DIRECTION.

REVISION CLOUD DELTA. SHOWN WITH CLOUD

AND INDICATES A CHANGE PER THE TITLE BLOCK.

SHEET NUMBER WHERE DIAGRAM IS PLACED

DIAGRAM NUMBER ON SHEET

SECTION

TOP = DIAGRAM NUMBER

BOTTOM = SHEET NUMBER

* NOTE *

ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN

THIS SET.THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE

USED IN THIS SET OF DRAWINGS.

QUANTITIES SHOWN ON SCHEDULES ARE PROVIDED FOR REFERENCE ONLY AND SHALL NOT

BE RELIED UPON FOR BIDDING OR CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL

REQUIRED QUANTITIES FROM THE CONTRACT DRAWINGS AND FIELD CONDITIONS.

ABBREV. DESCRIPTION

Ø ROUND

ABV ABOVE

AC AIR CONDITIONING

AD AREA DRAIN

ADD ADDENDUM

AFF ABOVE FINISHED FLOOR

AFUE ANNUAL FUEL UTILIZATION EFF.

ALT ALTERNATE

AP ACCESS PANEL

ARCH ARCHITECT/ARCHITECTURAL

BFF BELOW FINISHED FLOOR

BLW BELOW

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER HOUR

CAP CAPACITY

CB CATCH BASIN

CFM CUBIC FEET PER MINUTE

CLG CEILING

CO CLEAN OUT

CW COLD WATER

D DEGREE

DB DRY BULB

DIA DIAMETER

DN DOWN

DW DISTILLED WATER

EA EACH

EAT ENTERING AIR TEMPERATURE

ELEC ELECTRICAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

E/A EXHAUST AIR

EXIST EXISTING

F DEGREES FAHRENHEIT

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FL FLOOR

FO FUEL OIL

FOV FUEL OIL VENT

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FPM FEET PER MINUTE

FS FLOOR SINK

FT FOOT/FEET

FTR FIN TUBE RADIATION

GAL GALLON

GF GAS-FIRED

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

GW GREASE WASTE

HB HOSE BIB

HP HORSE POWER

HTG HEATING

HTR HEATER

HW HOT WATER

HYD HYDRANT

ID INDIRECT

IN INCH

INV INVERT

LB POUND

LB/HR POUNDS PER HOUR

LAT LEAVING AIR TEMPERATURE

LP LOW PRESSURE

LPG LIQUEFIED PETROLEUM GAS

ABBREV. DESCRIPTION

LVR LOUVER

LWT LEAVING WATER TEMPERATURE

M/A MIXED AIR

MAX MAXIMUM

MBH ONE THOUSAND BTU PER HOUR

MCF ONE THOUSAND CUBIC FEET

MD MOTORIZED DAMPER

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTR MOTOR

MU/A MAKE-UP/AIR

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NUMBER

NO NORMALLY OPEN

NTS NOT TO SCALE

O OXYGEN

O/A OUTSIDE AIR

ORD OVERFLOW ROOF DRAIN

PD PRESSURE DROP

PIV POST INDICATOR VALVE

PLBG PLUMBING

PRESS PRESSURE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH GAUGE

PWR POWER

R DUCT RISER

R/A RETURN AIR

RCP RADIANT CEILING PANEL

RD ROOF DRAIN

REC RECESSED

RED REDUCER

RH RELATIVE HUMIDITY

RL/A RELIEF AIR

RM ROOM

RPM REVOLUTIONS PER MINUTE

RW RAIN WATER

SF SQUARE FOOT

S/A SUPPLY AIR

SAN SANITARY

SF SQUARE FOOT

SD SMOKE DAMPER

SM SURFACE MOUNT

SP STANDPIPE

SP STATIC PRESSURE

STM STEAM

T THERMOSTAT

TD TEMPERATURE DROP

TDR TRENCH DRAIN

TEMP TEMPERATURE

TYP TYPICAL

UG UNDERGROUND

VAC VACUUM

V VENT

VAV VARIABLE AIR VOLUME

VENT VENTILATION

VTR VENT THROUGH ROOF

W WASTE

WB WET BULB

WCO WALL CLEAN OUT

WH WALL HYDRANT

ABBREV. DESCRIPTION

AC AIR CONDITIONING UNIT

ACCU AIR COOLING CONDENSING UNIT

AHU AIR HANDLING UNIT

AS AIR SEPARATOR

B BOILER

CH CHILLER

CT COOLING TOWER

CUH CABINET UNIT HEATER

CHWP CHILLED WATER PUMP

DBP DOMESTIC WATER BOOSTER PUMP

DC DUCT MOUNTED COIL

DCP DOM. WATER CIRCULATING PUMP

EF EXHAUST FAN

EDC ELECTRIC DUCT COIL

ABBREV. DESCRIPTION

ET EXPANSION TANK

EWH ELECTRIC WATER HEATER

FCU FAN COIL UNIT

FP FIRE PUMP

GI GREASE INTERCEPTOR

GRV GRAVITY ROOF VENTILATOR

HWP HEATING WATER PUMP

HRU HEAT RECOVERY UNIT

PRV POWER ROOF VENTILATOR

RE RETURN/EXHAUST FAN

RTU ROOFTOP UNIT

SP SUMP PUMP

UH UNIT HEATER

WH WATER HEATER

MECHANCIAL EQUIPMENT ABBREVIATIONS INDEX

MECHANICAL ABBREVIATION INDEX

AHU-1

MECHANCIAL SENSING DEVICE SYMBOLS LEGEND

SYMBOL DESCRIPTION

UNIT IDENTITY

TEMPERATURE SENSOR

TEMP/ HUMIDITY SENSOR

TEMP/ CO2 SENSOR

THERMOSTAT

HUMIDISTAT

HUMIDITY SENSOR

CARBON DIOXIDE DETECTOR

CARBON MONOXIDE DETECTOR

HYDROGEN GAS DETECTOR

HAZARDOUS GAS DETECTOR

NITROGEN DIOXIDE DETECTOR

OXYGEN GAS DETECTOR

TS

TH

TC

T

H

HS

P PRESSURE SENSOR

HVAC GENERAL NOTES

1 COORDINATE EXACT PLACEMENT OF DIFFUSERS, GRILLES, AND REGISTERS WITH ARCHITECTURAL

REFLECTED CEILING PLAN, TYPICAL.

2 SEE DETAIL FOR DIFFUSER CONNECTIONS TO DUCTWORK, TYPICAL.

3 BRANCH DUCTWORK SHALL BE SIZED TO MATCH THE NECK INLET SIZE OF THE DIFFUSERS,

REGISTER OR GRILLE IT SERVES UNLESS NOTED OTHERWISE, TYPICAL.

4 COORDINATE EXACT MOUNTING LOCATION OF ALL THERMOSTATS WITH LATEST REVISION OF

ARCHITECTURAL ELEVATION AND FURNISHINGS PLANS, TYPICAL.

5 THE MECHANICAL CONTRACTOR SHALL PROVIDE FIRE, SMOKE OR COMBINATION FIRE/SMOKE

DAMPERS AT ALL LOCATIONS SHOWN ON THE CONTRACT DOCUMENTS AND AS REQUIRED TO

MEET THE INTEGRITY OF ALL SMOKE AND FIRE PARTITIONS. THE CONTRACTOR SHALL REFER TO

THE LATEST ARCHITECTURAL LIFE SAFETY PLANS FOR ALL FIRE AND SMOKE PARTITION

LOCATIONS. DAMPERS ARE TO BE PROVIDED WITH SHUTOFF/TEST SWITCH AT EACH LOCATION.

6 PROVIDE AND INSTALL TURNING VANES IN ALL SQUARE LOW PRESSURE DUCTWORK AT ELBOWS

OR TEES, TYPICAL.

7 INSTALL ALL TERMINAL BOXES IN EASILY ACCESSIBLE AND SERVICEABLE LOCATIONS, MEETING

ALL MANUFACTURERS REQUIRED CLEARANCES ON EACH SIDE, SEE DETAILS, TYPICAL.

8 DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. REFER TO MECHANICAL

SPECIFICATIONS FOR EXTENT OF DUCT INSULATION AND LINER AND ADJUST SHEET METAL

DIMENSION.

9 PROVIDE AND INSTALL REMOTE DAMPER OPERATORS FOR ALL DAMPERS INSTALLED ABOVE

INACCESSIBLE CEILING, SEE MECHANICAL SPECIFICATIONS FOR EQUIPMENT REQUIREMENTS,

TYPICAL.

10 PROVIDE AND INSTALL HIGH EFFICIENCY TAKE-OFF FITTINGS AND BALANCING DAMPER AT ALL

BRANCH CONNECTIONS TO LOW PRESSURE DUCTWORK. PROVIDE BALANCING DAMPERS AT EACH

BRANCH TAKE OFF TO SERVE DIFFUSER OR GRILLE AS WELL AS WHERE INDICATED.

11 PROVIDE AND INSTALL HIGH EFFICIENCY OR CONICAL TAKE-OFFS AT ALL BRANCH CONNECTIONS

TO MEDIUM PRESSURE DUCTWORK.

12 WHERE DUCTWORK CROSSES, SUPPLY DUCTWORK IS USUALLY BELOW RETURN AND EXHAUST

DUCT. RETURN DUCTWORK IS USUALLY BELOW EXHAUST DUCTS.

13 AT LOCATIONS WHERE DIFFUSERS OR GRILLES ARE UNDER DUCTWORK, CONTRACTOR TO

FABRICATE TRANSITION BOOT FROM FLEX CONNECTION TO DIFFUSER OR GRILLE WITH BALANCING

DAMPER, TYPICAL.

14 THE MECHANICAL CONTRACTOR SHALL PROVIDE CEILING MOUNTED ACCESS DOORS FOR ALL

FIRE, SMOKE AND COMBINATION FIRE/SMOKE DAMPERS INSTALLED ABOVE INACCESSIBLE CEILING.

FIELD VERIFY EXACT INSTALLATION LOCATIONS PRIOR TO COMMENCING WORK AND COORDINATE

INSTALLATIONS WITH LATEST ARCHITECTURAL REFLECTED CEILING PLANS.

15 ALL VAV BOXES TO HAVE REHEAT COILS, EXCEPT AS NOTED. PROVIDE EQUIPMENT TAG TO MATCH SCHEDULE. PROVIDE A MINIMUM OF TWO DUCT DIAMETERS OF STRAIGHT ROUND DUCT TO INLET OF VAV BOX. BOX SHALL BE HARD CONNECTED (CONICAL) TO MEDIUM PRESSURE DUCT, TYPICAL.

16 PROVIDE ACCESS DOORS TO ACCESS VAV BOX CONTROLS ABOVE HARD CEILINGS. PROVIDE

MINIMUM 24" X 24".

17 FLEX DUCT IS REQUIRED FOR ALL DIFFUSERS AND GRILLES INSTALLED IN LAY-IN CEILINGS. FOR DIFFUSERS AND GRILLES IN HARD LID CEILINGS, THE DUCTWORK SHALL BE EXTENDED ALL THE

WAY TO THE DIFFUSER AND SHALL BE CONNECTED WITH A HARD CONNECTION OR A FLEX DUCT

CONNECTION WITH A MUD RING AND LAY-IN DIFFUSER AS SHOWN ON PLANS.

18 THE CONTRACTOR SHALL INFORM THE DESIGNER OF ANY PROPOSED DEVIATIONS FROM THE

CONTRACT DOCUMENTS.

19 PROVIDE ACCESS TO ALL TEMPERATURE CONTROLS ABOVE CEILING. LOCATE IN ACCESSIBLE

LOCATION. WHERE THERE ARE HARD CEILINGS, THE CONTRACTOR SHALL PROVIDE 24" X 24"

ACCESS DOOR.

20 SUPPLY AND RETURN PIPING TO COILS ARE THE SAME SIZE.

21 CONTRACTOR SHALL LOCATE AND TEMPERATURE SENSORS AT 4'-0" AFF, A MINIMUM OF 8" FROM

LIGHT SWITCH, UNLESS OTHERWISE NOTED ON THE ARCHITECT'S ELEVATIONS. COORDINATE

EXACT LOCATIONS WITH ARCHITECT.

22 REFER TO MECHANICAL PIPING OR ZONING DRAWINGS FOR THERMOSTAT AND TEMPERATURE

SENSOR LOCATIONS.

23 CONDENSATE DRAINS SHALL BE SUPPLIED FOR ALL COOLING EQUIPMENT. CONTRACTOR SHALL

ENSURE PROPER INSTALLATION AND DRAINAGE AS REQUIRED BY FEDERAL, STATE, AND LOCAL

CODES. CONDENSATE PIPING SHALL BE TYPE "L" COPPER UNLESS OTHERWISE NOTED IN THE

SPECIFICATIONS.

24 PROVIDE A 6" HOUSEKEEPING PAD FOR EACH PIECE OF MECHANICAL EQUIPMENT THAT IS FLOOR

MOUNTED. COORDINATE SIZES WITH MECHANICAL EQUIPMENT SELECTED.

25 ALL SUPPLY, RETURN, AND EXHAUST DUCTWORK SHALL BE RATED FOR PRESSURE CLASS OF 2"

W.G. UNLESS NOTED OTHERWISE ON THE PLANS OR IN THE SPECIFICATIONS.

26 THIS CONTRACTOR SHALL BE REQUIRED TO REPLACE FILTERS ON HVAC EQUIPMENT AFTER ALL

DUST PRODUCING CONSTRUCTION HAS BEEN COMPLETED AND PRIOR TO THE FINAL PUNCH.

PROJECT REQUIREMENTS

1 THE PROJECT GENERAL NOTES APPLY TO ALL DISCIPLINES.

2 REMOVE ALL UNUSED PIPING, DUCTWORK, EQUIPMENT, AND ACCESSORIES.

3 THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN THE SCOPE OF WORK SPACE AND WITHIN CLOSE PROXIMITY TO THE SCOPE OF WORK SPACE. THE CONTRACTOR WILL FIELD VERIFY AS MUCH AS IS REASONABLE BEFORE THE FINAL BID. AFTER THE FINAL BID THE CONTRACTOR WILL NOTIFY THE OWNER, ARCHITECT, AND MECHANICAL DESIGN ENGINEER IMMEDIATELY UPON

DISCOVERY OF EXISTING CONDITIONS THAT MAY AFFECT THE DESIGN.

4 THE MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR ON THE EXISTING

EQUIPMENT AND ITS ACCESSORIES AS FOLLOWS: CLEAN ALL COILS, REPLACE THE FILTERS AND

BELTS, INSPECT, REPAIR, OR REPLACE THE ECONOMIZERS, DRIVERS AND FAN BEARINGS,

MOTORS, CONTROL COMPONENTS, VALVES, AND ANY OTHER ITEM NECESSARY FOR A COMPLETE

AND PROPER OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE, PRIOR TO

FINAL BIDDING, AND VERIFY ALL EXISTING SITE CONDITIONS. PROVIDE ALL MATERIAL AND

COMPONENTS AS NEEDED TO BRING THE UNITS TO FULL COMPLIANCE OF THE OWNER’S CRITERIA

AND LOCAL AUTHORITY HAVING JURISDICTION.

5 WHERE FLOOR DRAINS OCCUR WITH THE LIMITS OF CONSTRUCTION, PREVENT CONSTRUCTION

DEBRIS FROM ENTERING DRAIN BODY BY SEALING DRAIN OPENING PRIOR TO START OF WORK.

UNSEAL DRAINS AT COMPLETION OF CONSTRUCTION.

6 COORDINATE INSTALLATION OF PIPING, DUCTWORK, CONDUIT, LIGHTS, CABLE TRAY, STRUCTURE, EQUIPMENT, CEILINGS, ARCHITECTURAL COMPONENTS, AND ANYTHING ELSE PERTAINING TO THE

PROJECT TO PREVENT CONFLICTS.

7 THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS BOTH EXISTING AND THOSE ILLUSTRATED BY THESE DOCUMENTS AND THOSE OF OTHER DISCIPLINES, INCLUDING, BUT NOT LIMITED TO ARCHITECTURAL, CIVIL, ELECTRICAL, VENTILATION, PLUMBING, AND OTHER SYSTEMS

INVOLVED ON THIS PROJECT.

8 FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL CONFORM TO ALL

REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING BUT NOT

LIMITED TO THE INTERNATIONAL BUILDING CODE, INTERNATIONAL MECHANICAL CODE, AND

INTERNATIONAL PLUMBING CODE.

9 LOCATE EQUIPMENT REQUIRING ACCESS 2'-0" MAXIMUM ABOVE CEILING.

10 ALL ROOF MOUNTED EQUIPMENT SHALL BE A MINIMUM 10'-0" FROM EDGE OF ROOF.

11 COORDINATE INSTALLATION OF DUCTWORK, PIPING AND MECHANICAL EQUIPMENT WITH NEC

CLEARANCES INCLUDING THE SPACE ABOVE ELECTRICAL PANELS, TRANSFORMERS AND OTHER

ELECTRICAL EQUIPMENT. NO PIPING OR DUCTWORK TO RUN OVER ELECTRICAL PANELS, VFD'S OR MCC'S. PROTECT EQUIPMENT WITH A 42" DEEP ZONE IN FRONT OF PANELS, VFD'S AND MCC'S.

PROVIDE PANS IF REQUIRED UNDER PIPING.

12 FIRE SEAL AROUND DUCT AND PIPING PENETRATIONS OF FIRE RATED WALLS. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CAULKING AND SEALING ALL PENETRATIONS IN FIRE

AND SMOKE RATED PARTITIONS TO MAINTAIN RATINGS. REFER TO SPECIFICATION.

13 PROVIDE SLEEVES AND/OR OPENINGS TO RUN PIPES AND DUCTS THROUGH FOUNDATIONS,

FLOORS, WALLS, AND ROOF.

14 TRANSITION PIPING AND DUCTWORK SIZES TO MATCH THE SIZE OF EQUIPMENT CONNECTION.

15 REFER TO PLUMBING SERIES DRAWINGS FOR GAS PIPING.

16 ALL PIPE AND DUCT SIZES SHOWN SHALL BE CONTINUED IN THE DIRECTION OF FLOW UNTIL

ANOTHER SIZE IS SHOWN.

17 FOR DETAILS, EQUIPMENT CONNECTIONS, AND PIPE SIZES NOT SHOWN ON THE SEGMENTS, REFER

TO DETAILS, SCHEDULES, AND SPECIFICATIONS.

18 INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S WRITTEN

INSTALLATION INSTRUCTIONS, AT A LEVEL OF WORKMANSHIP CONSISTENT WITH THE

SPECIFICATIONS.

19 MECHANICAL CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT IS PROVIDED AND INSTALLED

WITH CLEARANCES PER MANUFACTURERS RECOMMENDATIONS. THE CONTRACTOR SHALL

MAINTAIN PROPER SERVICE SPACE FOR COIL PULLS, BAS DEVICES, MAINTENANCE ACCESS, ETC.

20 INSTALL EXPOSED PIPING AND DUCTWORK AS HIGH AS PRACTICAL IN ROOMS WITHOUT CEILINGS.

21 LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT, AS INDICATED ON THE DRAWING, ARE

APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD, INCLUDING, BUT NOT LIMITED

TO, OFFSETS AND TRANSITIONS. NEW DUCTWORK, PIPING AND EQUIPMENT SHALL BE

COORDINATED WITH STRUCTURE, LIGHTS, REFLECTED CEILING PLANS, CABLE TRAY, ELECTRICAL CONDUIT, PLUMBING, MECHANICAL AND FIRE PROTECTION PIPING, MEDICAL GASES, ALL OTHER

TRADES AND ALL OTHER EXISTING CONDITIONS TO AVOID INTERFERENCE IN THE FIELD..

22 THE CONTRACTOR SHALL INFORM THE DESIGNER OF ANY PROPOSED DEVIATIONS FROM THE

CONTRACT DOCUMENTS.

23 IF CONTRACTOR ENCOUNTERS MATERIAL WHICH MAY CONTAIN ASBESTOS, IMMEDIATELY STOP

WORK IN THIS AREA AND NOTIFY THE OWNER.

24 DETAILS REFERENCE ALL SHEETS.

25 INSTALL ALL PIPING AND DUCTWORK WITHOUT FORCING OR SPRINGING.

26 ROUTE DOMESTIC WATER, FIRE PROTECTION, SANITARY WASTE, ROOF DRAIN, CAMPUS CHILLED OR HOT WATER, AND ANY OTHER UTILITY SERVICES TO SITE UTILITIES 5'-0" FROM BUILDING

UNLESS NOTED OTHERWISE. REFER TO CIVIL PLANS.

27 LOCATE VALVING, ACCESSORIES, AND EQUIPMENT IN ACCESSIBLE LOCATIONS. WHERE LOCATED ABOVE HARD CEILING PROVIDE AN ACCESS DOOR IN CEILING. MINIMUM ACCESS DOOR SIZE OF 24"

X 24". COORDINATE EXACT LOCATION AND STYLE WITH ARCHITECT. EQUIPMENT SHALL BE

LOCATED IN THE CEILING CAVITY SO IT CAN BE SAFELY SERVICED FROM SOMEONE STANDING ON

A LADDER PLACED BELOW THE CEILING ACCESS.

28 WHERE VALVING, ACCESSORIES, OR EQUIPMENT IS LOCATED IN A WALL, PROVIDE AN

APPROPRIATELY SIZED ACCESS DOOR. COORDINATE ACCESS DOOR SIZE, LOCATION, AND STYLE

WITH ARCHITECT.

29 CONTRACTOR TO PROVIDE VALVE IDENTIFICATION AND LOCATION ON ALL CEILING TILES WHERE

VALVES ARE LOCATED.

30 CONTRACTOR TO PROVIDE DELEGATED DESIGN OF SEISMIC BRACING AS A DEFERRED SUBMITTAL.

SEE SPECIFICATION 23 0548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC.

31 CONTRACTOR TO PROVIDE BIM COORDINATION AND VIRTUAL DESIGN AND CONSTRUCTION

SERVICES TO A XXX LEVEL OF DETAIL. SEE SPECIFICATION 23 0099-BIM COORDINATION.

HVAC SHEET INDEX

ME001 HVAC TITLE SHEET

MD101 MECHANICAL DEMO PLAN

M101 MECHANICAL PLAN

M501 MECHANICAL DETAILS AND SCHEDULES

181 E 5600 S, Ste #200 Murray, UT 84107

(801) 530-3148 | www.resolutgroup.com Resolut Project #: 260666

L I C

E N

S E

D

P R

OFESS I ONA

L

E N

G I N

E E

R

No. 190991

S

T A

T E O F U T

A H

BENJAMIN L.

DAVIS

07/01/2026

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

PA

PM

PROJECT NUMBER

P M

ME001

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

HVAC TITLE SHEET

260666

# DESCRIPTION DATE

2 C

D

E

F G

H

J

7 1/2"x11"

(E)SG 0

7 1/2"x23"/---

(E)RG 0

10"x10"/24x24

250(E)CD-2

10"x10"/24x24

250(E)RG-2

10"Ø/24x24

250(E)CD-

N5

N5

N7

N7

N8

N10

N10

N9 N9

N12

A

B

2 C

D

E

F G

H

J

N3

N3

N6

N6

(E)12"x8" SA

12"x8" RA

181 E 5600 S, Ste #200 Murray, UT 84107

(801) 530-3148 | www.resolutgroup.com Resolut Project #: 260666

L I C

E N

S E

D

P R

OFESS I ONA

L

E N

G I N

E E

R

No. 190991

S

T A

T E O F U T

A H

BENJAMIN L.

DAVIS

07/01/2026

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

PA

PM

PROJECT NUMBER

P M

MD101

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

MECHANICAL DEMO

PLAN

260666

KEYNOTES

N3 EXISTING DUCT CONTINUES TO FURNACE IN MECHANICAL ROOM. NO

CHANGES ARE TO BE MADE BEYOND THIS POINT.

N5 DEMOLISH EXISTING SUPPLY AND RETURN GRILLES AND

ASSOCIATED DUCTWORK IN COUNTER BEING DEMOLISHED. SEE

VIEW 2 ON THIS SHEET FOR EXTENT OF DUCTWORK TO BE REMOVED

IN BASEMENT.

N6 DEMOLISH DUCTWORK TO THIS POINT. SEE M101 FOR NEW

DUCTWORK.

N7 EXISTING GRILLES IN OFFICE ARE TO REMAIN.

N8 EXISTING GRILLE IN OPEN OFFICE IS TO BE REMOVED. DUCTWORK IS

TO REMAIN.

N9 EXISTING DUCTWORK CONNECTS TO ROOF TOP UNIT. NO WORK IS

BEING DONE TO ROOFTOP UNIT.

N10 DUCTWORK IS ROUTED ON ROOF WITH ROOF PENETRATIONS TO

EACH GRILLE.

N12 ELBOW TO EXISTING GRILLE TO BE DEMOLISHED. ROOF

PENETRATION TO REMAIN FOR NEW CONNECTION AND DUCT

EXTENDED TO NEW RETURN GRILLE. SEE M101 FOR NEW DUCTS.

3/16" = 1'-0"

BASEMENT MECHANICAL DEMO PLAN

3/16" = 1'-0"

LEVEL 01 MECHANICAL DEMO PLAN

2 C

D

E

F G

H

J

PRINT ROOM

OFFICE/ CONFERENCE ROOM

Space

Space

Space

OFFICE

OFFICE

HALLWAY

RECEPTION

ART GALLERY

ART GALLERY

N4

10"x10"/24x24

250(E)CD-2

10"x10"/24x24

250RG-2

10"x10"/24x24

250(E)RG-2

10"x10"/24x24

250CD-2

N9 N9

8"x24"/---

RG-1 200

N10

N10 (E)10"x10" SA

10"x10" RA

N11

10"x10" SA

7 1/2"x11"

SG-1 200N4

A

B

2 C

D

E

F G

H

J

N1

N2

N3

N3

(E)12"x8" SA

8"x24" RA

12"x8" SA

181 E 5600 S, Ste #200 Murray, UT 84107

(801) 530-3148 | www.resolutgroup.com Resolut Project #: 260666

L I C

E N

S E

D

P R

OFESS I ONA

L

E N

G I N

E E

R

No. 190991

S

T A

T E O F U T

A H

BENJAMIN L.

DAVIS

07/01/2026

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

PA

PM

PROJECT NUMBER

P M

M101

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

MECHANICAL PLAN

260666

KEYNOTES

N1 EXISTING DUCT TO CONNECT TO NEW PLENUM FROM NEW FLOOR

RETURN GRILLE ABOVE.

N2 EXISTING SUPPLY DUCT TO CONNECT TO NEW SUPPLY DUCT.

N3 EXISTING DUCT CONTINUES TO FURNACE IN MECHANICAL ROOM. NO

CHANGES ARE TO BE MADE BEYOND THIS POINT.

N4 NEW GRILLES TO BE PLACED IN FLOOR. COORDINATE LOCATION

WITH ARCHITECTURE AND EXISTING STRUCTURE. STRUCTURE

SHALL NOT BE ALTERED TO INSTALL NEW DUCTWORK AND GRILLES.

N9 EXISTING DUCTWORK CONNECTS TO ROOF TOP UNIT. NO WORK IS

BEING DONE TO ROOFTOP UNIT.

N10 DUCTWORK IS ROUTED ON ROOF WITH ROOF PENETRATIONS TO

EACH GRILLE.

N11 LOCATION FOR NEW GRILLE TO BE COORDINATED WITH ROOF

STRUCTURE. EXISTING DUCT THAT TURNS DOWN TO EXISTING

GRILLE IS TO BE TURNED AND ROUTED TO NEW LOCATION.

3/16" = 1'-0"

BASEMENT MECHANICAL PLAN

3/16" = 1'-0"

LEVEL 01 MECHANICAL PLAN

INSULATION

METAL DECK

PROVIDE PITCH WITH

INSULATION MATERIAL

FOR DRAINAGE

STRUCTURAL SHAPE

AS PER SMACNA

(ANGLE IRON OR PIPE)

SUPPORT LEGS

WELD TO ANGLE (TYPICAL)

ANGLE IRON FASTENED

TO EQUIPMENT SUPPORT

COUNTER FLASHING

HOOD

MEMBRANE ROOF

PREFABRICATED

EQUIPMENT

SUPPORT

INVERTED ANGLE IRON

ANCHOR EQUIPMENT SUPPORT

TO METAL DECK

DUCTWORK SUPPORTED

AS PER SMACNA

SEAL ALL ANGLES

WEATHER TIGHT

INSULATED SUPPLY OR

RETURN DUCTWORK

ANGLE IRON WELD TO PIPE

OR ANGLE IRON (TYPICAL)

AT ROOF DUCT SUPPORT-INSULATE

OVER ANGLE IRON SUPPORTS AND

SEAL ALL CORNERS OF ANGLES IN A

WEATHER TIGHT MANNER

M

IN

IM

U

M

2' -0

DUCT SUPPORT

INSULATION

WHERE REQUIRED

RECTANGULAR OR

ROUND DUCTWORK

CAULK ALL AROUND

COUNTER FLASHING

SHEETMETAL

SAFING TIGHT

TO DUCT

WOOD

NAILER

BUILT UP

ROOF

BASE FLASHING

WOOD NAILER

INSULATION

WOOD JOISTS

PREFABRICATED, INSULATED

CURB, MOUNT AND SECURE

ON WOOD NAILER. (BASE)

12"

MIN.

181 E 5600 S, Ste #200 Murray, UT 84107

(801) 530-3148 | www.resolutgroup.com Resolut Project #: 260666

L I C

E N

S E

D

P R

OFESS I ONA

L

E N

G I N

E E

R

No. 190991

S

T A

T E O F U T

A H

BENJAMIN L.

DAVIS

07/01/2026

PROJECT ARCHITECT

PROJECT MANAGER

C EDA

[A] The Boston Building

9 Exchange Place, Suite 1100

Salt Lake City, Utah 84111

[O] 801 531 7600

[E] info@edaarch.com

[W] www.edaarch.com

PA

PM

PROJECT NUMBER

P M

M501

ART BARN

INFRASTRUCTURE AND

ACCESSIBILITY

IMPROVEMENTS

54 FINCH LANE, SALT LAKE

CITY, UT 84102

MECHANICAL DETAILS

AND SCHEDULES

260666

GRILLE, REGISTER, AND DIFFUSER SCHEDULE

ID TYPE MANUFACTURER MODEL COUNT DESCRIPTION

RG-1 KEES FHD0 1

SG-1 KEES FHD0 1

CD-2 PRICE SPD 1 STYLE: SQUARE PLAQUE FACE CEILING DIFFUSER

CONSTRUCTION: STEEL

FINISH: POWDER COAT WITH COLOR SELECTED BY…