- NE WRF Influent Building Floor Repair
- Solicitation number
- 25-0004-UT
- Issued by
- Pinellas County, Clewiston City, Florida
About this file
This is an Invitation for Bid (IFB) plan document prepared by the City of Clearwater, Florida Engineering Department for the NE WRF Influent Building Floor Repair project (Contract No. 25-0004-UT). The project scope encompasses the demolition of existing grating over channels in the influent headworks building through the splitter box and the installation of new grating to replace it. Specific work includes removal and replacement of grating and existing support ledgers and beams at the influent box and channel, removal and replacement of grating over the headcell influent channel at both north and south channels with additional anchors to existing supports, and selective demolition of grating and grating supports at the downstream effluent channel and distribution well. The contractor must field-verify all existing conditions, as not all existing conditions are captured in the drawings, and an engineer's site visit will identify specific members requiring replacement. The project is located at the Northeast Water Reclamation Facility in Clearwater, Florida, with a construction timeline of 365 days.
The contractor is responsible for furnishing all labor, materials, equipment, tools, services, and incidentals necessary to complete the work in a complete and ready-for-service condition, including repairs, testing, permits, cleanup, replacements, and restoration of any damages caused during construction. All work must comply with applicable local, state, and federal codes. The existing analyzer cabinet will be relocated by others. The plans were prepared by ARDURRA, a professional engineering firm, with input from 100% Submittal Engineering and reviewed by the City of Clearwater Engineering Department. The document includes eight detailed photographs showing the current conditions of grating at various locations within the influent building to facilitate contractor understanding of existing conditions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NE_WRF_Influent_Building_Floor_Repair.pdf | ||
| NE_WRF_Inf_Bldg_Flr_Proposed_Contract_Time.pdf | ||
| NE_WRF_Inf_Bld_IFB_Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRATING AT INFLUENT BOX AND CHANNEL
PHOTO NO.1
GRATING AT INFLUENT BOX AND CHANNEL (UNDERSIDE VI EW)
PHOTO NO.5
NOTES:
1. NOT ALL EXISTING CONDITIONS ARE INTENDED TO BE CAPTURED IN THE DRAWINGS. THE CONTRACTOR
MUST FIELD VERIFY ALL EXISTING CONDITIONS.
2. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT EXISTING STRUCTURES AND
EQUIPMENT FROM DAMAGE WHEN WORKING IN AND AROUND THE BUILDING.
SURVEYED BY:
REVIEWED BY:
APPROVED BY:
[iJ
KEY NOTES
REMOVE AND REPLACED GRATING AND EXISTING SUPPORT LEGERS AND BEAMS; REFER TO
SHEET S1 .04 FOR REPAIR AND REPLACEMENT
REMOVE AND REPLACE GRATING OVER HEADCELL INFLUENT CHANNEL, OCCURS AT BOTH NORTH AND SOUTH CHANNELS. SUPPORTS TO REMAIN AND RECEIVE ADDITIONAL ANCHORS; REFER TO SHEET S1 .05
PROVIDE SELECTIVE DEMOLITION OF GRATING AND GRATING SUPPORTS AT DOWNSTREAM
EFFLUENT CHANNEL AND DISTRIBUTION WELL. REFER TO SHEET S1 .05 FOR SCOPE OF REPAIRS
AND SCHEDULING OF ENGINEER'S SITE VISIT TO IDENTIFY MEMBERS TO BE REPLACED.
EXISTING ANALYZER CABINET TO BE RELOCATED BY OTHERS
RECORD DRAWINGS
DRAWN BY:
PROJECT ENGINEER DATE
DATE REVISION
GRATING AT INFLUENT CHANNELS
PHOTO NO.2
GRATING AT HEADCELL INFLUENT CHANNEL
PHOTO NO.6
BY DATE
CITY OF CLEARWATER, FLORIDA
ENGINEERING DEPARTMENT
100 S. MYRTLE AVE.
CLEARWATER, FL 33756
GRATING AT INFLUENT BOX AND CHANNEL
PHOTO NO.3
GRATING AT HEADCELL INFLUENT CHANNEL
PHOTO NO.7
LEGEND
v z;,,1 INDICATES DEMOLITION AS NOTED
GRATING AT INFLUENT CHANNELS
PHOTO NO.4
DOWNSTREAM COVERED EFFLUENT CHANNEL
PHOTO NO.8
100% SUBMITTAL
ENGINEERING
1320 WILFRED DRIVE
ORLANDO, FL 32803
PH: 407.219.4454
WEKIVA PROJ. NO. 25-104
FL ENG BUSINESS NO. 31920
DWG NAME:
ARDURRA
COLLABORATE". INNOVATE. CREATE.
4921 Memorial Highway One Memorial Center, Suite 300
Tampa, Florida 33634 Phone: (813) 880-8881 www.Ardurra.com License #2610
FIELD BOOK: SURVEYED BY:
G;) "cALLros•ii NE WRF INFLUENT BUILDING FLOOR REPAIRS CONTRACT NO.:
25-0004-UT
DATE DRAWN:
5/04/2026
N/A
DRAWN BY:
DSM SUNSHINE STATE
ONE CALL
OF FLORIDA
www.callsunshine.com
(800) 432-4770
MIN. 48 HOURS
BEFORE YOU EXCAVATE -·· - --- - ·-- --
PHOTOGRAPHS - GRATING REPAIRS
JOB NO.: DESIGNED BY: CHECKED BY:
2025-1239 DSM JVS ,
APPROVED BY
ENGINEER OF RECORD FL PE#
S1.03
SCALE:
VERT. NA
HORIZ. NA
SHEET NO.:
OF
DATE
| S1.01 |
| S1.02D |
| S1.02 |
| S1.03 |
| S1.04 |
| S1.05 |
| S1.06 |
| 2026-06-04T18:23:00-0400 | |
| Tara Kivett |
File details come from the government source that posted it. Updated .