Clinton_Nurse Call_Life Safety Plan - Main Floor.pdf

PDF 511 KB Posted

Attached to
The Contractor shall provide and install a new wired auxiliary IP-based wireless nurse call system and remove the old system components.
Solicitation number
246-24-Q-0007
Issued by

About this file

This document includes a life safety plan drawing and related federal contract opportunity solicitation. The life safety plan drawing depicts the first floor layout of the Clinton Indian Health Center in Clinton, Oklahoma and includes the location of fire walls, exits, detectors, alarms and other life safety equipment.

The related federal contract opportunity solicitation seeks offers to provide and install a new wired auxiliary IP-based wireless nurse call system at the Clinton Indian Health Center and remove the existing system components. The solicitation was issued by the Department of Health and Human Services Indian Health Service. Offerors are required to submit responses by the date specified to be considered for award of the contract to provide the nurse call system and perform the required installation and removal work.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DNUP

145.1657 45.1018164.0621

ELECTRICAL ROOM

TELEPHONE EQ

ACCESS CONTROL PANEL

D

D

D

D

D

D

D D D

D

F1

F1

CORR

C O

R R

CORR CORR

C O

R R

C O

R R

C O

R R

CORR

C O

R R

CORR

C O

R R

C O

R R

C O

R R

CORR

C O

R R

C O

R R

C O

R R

C O

R R

C O

R R

IT CLOSET

S

S

S

S

S

SS

S

SH

SH

S H

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH SH

SH

SH

SH

M

M

M

SH

SH

SH

SH

SH

FE

FE

FE

FE

#1

#22

#3

#9

M

M

S

M

S

S

S

S

SS

S

S

S

S

S

H

S

S

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

D

INDIAN HEA

L

TH

SERV I CE

1 9

F1 F1

D

CORR

SP

F C

H

SH

S

S

M

D

FIRST FLOOR

MAIN BUILDING

CLINTON INDIAN HEALTH CENTER

CLINTON, OKLAHOMA

AutoCAD SHX Text

FACP

AutoCAD SHX Text

MFACP

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

LAYOUT NAME:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION DESCRIPTION

AutoCAD SHX Text

INIT.

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

PROJ ENG:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OFFICE OF ENVIRONMENTAL

AutoCAD SHX Text

HEALTH & ENGINEERING

AutoCAD SHX Text

DIVISION OF FACILITIES

AutoCAD SHX Text

MANAGEMENT

AutoCAD SHX Text

701 MARKET DRIVE

AutoCAD SHX Text

OKLAHOMA CITY, OKLAHOMA 73114

AutoCAD SHX Text

OKLAHOMA CITY AREA

AutoCAD SHX Text

REV

AutoCAD SHX Text

LIFE SAFETY-CLINTON-01

AutoCAD SHX Text

FIRST FLOOR

AutoCAD SHX Text 09/17/2015

AutoCAD SHX Text

BOBBIE GONZALEZ

AutoCAD SHX Text

JACK SHIELD

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text

CLINTON, OKLAHOMA

AutoCAD SHX Text

LIFE SAFETY

AutoCAD SHX Text

LS-01

AutoCAD SHX Text

LIFE SAFETY

AutoCAD SHX Text

1 HR FIREWALL

AutoCAD SHX Text

FIRE EXTINGUISHER

AutoCAD SHX Text

PULL STATION

AutoCAD SHX Text

FIRE DAMPER

AutoCAD SHX Text

CORRIDOR WALL

AutoCAD SHX Text

EXIT LIGHTS

AutoCAD SHX Text

SMOKE PARTITION

AutoCAD SHX Text

EMERGENCY LIGHTING

AutoCAD SHX Text

FIRE DOOR

AutoCAD SHX Text

CORRIDOR DOOR

AutoCAD SHX Text

SECURITY CAMERA

AutoCAD SHX Text

MOTION DETECTOR

AutoCAD SHX Text

SMOKE DETECTOR

AutoCAD SHX Text

HEAT DETECTOR

AutoCAD SHX Text

HORN / STROBE

AutoCAD SHX Text

STROBE

AutoCAD SHX Text

FACP

AutoCAD SHX Text

FIRE ALARM CONTROL PANEL

AutoCAD SHX Text

DUCT SMOKE DETECTOR

AutoCAD SHX Text

MFACP

AutoCAD SHX Text

MAIN FIRE ALARM CONTROL PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .