Waters Middle School ADA Restroom Renovations - Final Drawings
This set of final construction drawings comprises the architectural, structural, plumbing, mechanical, and electrical design documents for ADA restroom renovations at Waters Middle School, located at 600 Roosevelt Road, Portsmouth, Virginia 23701. The project involves comprehensive renovation of multiple existing restrooms throughout the first floor of the facility, constructed in 1965, including demolition and new construction of ceilings, wall and floor finishes, associated HVAC equipment, lighting, installation of new walls, doors, ceilings, and floor and wall finishes. The scope encompasses approximately 20 restroom spaces with varying sizes, accessibility requirements, and fixture configurations. The drawings are dated September 2, 2025, and marked as 100% Bid Documents, indicating they are final construction documents ready for contractor bidding and procurement under IFB #44-26-SKL. The project maintains the existing building's Educational Group E occupancy classification and does not alter life safety or egress plans, with the existing 1965 construction type remaining unchanged.
The renovation work includes structural modifications such as demolition and reconstruction of concrete masonry unit (CMU) walls, installation of new fire-rated partitions with 1-hour fire resistance ratings in specific shower room storage areas per Virginia Construction Code requirements, and concrete slab infill work. Architectural specifications detail extensive tile work, including removal of existing mosaic and ceramic tiles with installation of new porcelain and ceramic tile finishes, new plumbing fixtures with ADA-compliant wash fountains and drinking fountains, new HDPE toilet partitions with grab bars and accessories, new lighting and HVAC diffusers, and new hollow metal doors with appropriate fire ratings. Hazardous materials management is required, including asbestos-containing material (ACM) removal from mudded pipe fittings, door frame sealants, and undersink mastic, as well as lead paint abatement on exterior painted surfaces. The project incorporates ADA accessibility standards throughout, with detailed specifications for accessible toilet stalls, turning radiuses, grab bar placements, and fixture heights in accordance with ICC A117.1 standards.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
S
U A
N C
E S
C H
E D
U L
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
N U
M B
R
D A
T
S C
R
IP
T
IO
N
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
A ut od es k D oc s:
//P or ts m ou th
P ub lic S ch oo ls
H ub
_R
W
_A R
C H
_W at er s
M S
A D
A R
R R en ov at io n_ R
.r vt
9/ 2/
:1
5:
A M
COVER SHEET
G-001
A.GENUNG
M. MIJAL
F. FRENCH
10012314.07
09/02/2025
W A
T E
R S
M
ID
D L
E S
C H
O O
L C
IT
Y
O F
P O
R T
S M
O U
T H
R O
O S
E V
E
LT
R D
P O
R T
S M
O U
T H
, V A
A D
A R
E S
T R
O O
M R
E N
O V
A T
IO
N
S
SHEET INDEX
SHEET NUMBER SHEET NAME
P-602 Unnamed
GENERAL
G-001 COVER SHEET
GENERAL
GI001 CODE SUMMARY
GI101 LIFE SAFETY PLAN - FIRST FLOOR
HAZMAT
HM101 1ST FLOOR OVERALL PLAN - REMOVAL
STRUCTURAL
S-001 GENERAL NOTES
S-101 OVERALL PLAN
S-102 ENLARGED PLANS
S-103 ENLARGED PLANS
ARCHITECTURE
A-001 SYMBOLS AND ABBREVIATIONS
AD101 FIRST FLOOR OVERALL PLAN - DEMOLITION
AD111 FIRST FLOOR REFLECTED CEILING PLAN - DEMOLITION
A-101 FIRST FLOOR OVERALL PLAN - NEW CONSTRUCTION
A-111 FIRST FLOOR REFLECTED CEILING PLAN - NEW CONSTRUCTION
A-401 ENLARGED TOILET PLANS
A-402 ENLARGED TOILET PLANS
A-403 ENLARGED TOILET PLANS
A-411 ENLARGED CEILING PLANS
A-412 ENLARGED CEILING PLANS
A-413 ENLARGED CEILING PLANS
A-431 TYPICAL TOILET ELEVATIONS AND PLANS, ACCESSORY ELEVATIONS
A-601 DOOR SCHEDULE & TYPES, PARTITION TYPES AND MISCELLANEOUS DETAILS
A-701 INTERIOR FINISH SCHEDULE AND FINISH LEGEND
A-702 FIRST FLOOR FINISH PLAN
PLUMBING
P-001 LEGEND, NOTES AND ABBREVIATIONS
P-002 FIXTURE PLATES
P-003 FIXTURE PLATES
PD-101 OVERALL FIRST FLOOR PLAN - DEMOLITION
P-101 OVERALL FIRST FLOOR PLAN - NEW CONSTRUCTION
P-401 ENLARGED PLUMBING FLOOR PLANS
P-402 ENLARGED PLUMBING FLOOR PLANS
P-403 ENLARGED PLUMBING FLOOR PLANS
P-601 WASTE RISER DIAGRAMS
ELECTRICAL
E-001 LEGEND, NOTES AND ABBREVIATIONS
ED101 OVERALL DEMOLITION FLOOR PLAN
E-101 OVERALL NEW WORK FLOOR PLAN
E-401 ENLARGED DEMOLITION AND NEW WORK PLANS
E-402 ENLARGED DEMOLITION AND NEW WORK PLANS
E-403 ENLARGED DEMOLITION AND NEW WORK PLANS
E-404 ENLARGED DEMOLITION AND NEW WORK PLANS
E-501 DETAILS
E-601 DETAILS, RISER AND SCHEDULES
PROJECT SITE
PROJECT SITE
THE PROJECT CONSISTS OF THE RENOVATION OF EXISTING
RESTROOMS: CEILINGS; WALL AND FLOOR FINISHES; ASSOCIATED
HVAC EQUIPMENT; LIGHTING; INSTALLATION OF NEW WALLS; DOORS;
CEILINGS; FLOOR AND WALL FINISHES; HVAC DIFFUSERS AND
ELECTRIC DEVICES.
BUILDING DATE OF CONSTRUCTION: 1965
CITY OF PORTSMOUTH
WATERS MIDDLE SCHOOL
ADA RESTROOM RENOVATIONS
02 SEPTEMBER 2025
WOOLPERT
ARCHITECTURE - LIFE SAFETY - INTERIORS
4433 CORPORATION LANE, SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
GEOENVIRONMENTAL
RESOURCES, INC
ASBESTOS ABATEMENT - DEMOLITION
2712 SOUTHERN BOULEVARD, SUITE101
VIRGINIA BEACH, VA 23462
757.463.3200
MCPHERSON DESIGN GROUP
INC.
STRUCTURAL
192 BALLARD COURT SUITE 102
VIRGINIA BEACH, VA 23462
757.965.2000
PACE COLLABORATIVE
PLUMBING, MECHANICAL, ELECTRICAL
1277 PERIMETER PKWY,
VIRGINIA BEACH, VA 23454
757.499.7223
LOCATION MAPVICINITY MAP
PROJECT NAME: WATERS MIDDLE SCHOOL ADA RESTROOM RENOVATIONS
PROJECT NAME: CRADOCK MIDDLE SCHOOL ADA RESTROOM RENOVATIONS
VCC: VIRGINIA CONSTRUCTION CODE (VCC) 2021
USE GROUP: EDUCATIONAL GROUP E
CONSTRUCTION TYPE: CONSTRUCTION TYPE IS EXISTING TO REMAIN
SPRINKLER SYSTEM: THE EXISTING BUILDING IS NOT PROTECTED BY AN AUTOMATIC
SPRINKLER SYSTEM
FIRE ALARM SYSTEM: AN EXISTING FIRE DETECTION SYSTEM IS PROVIDED
SEPARATION: BUILDING SEPARATION AND EXPOSURE PROTECTION ARE EXISTING
OCCUPANT LOADS: RENOVATION TO THE EXISTING RESTROOMS WILL NOT INCREASE OR
DECREASE THE OCCUPANT LOAD
DESIGN LOADS: REFER TO DESIGN LOADS LISTED ON S-001
PROJECT TYPE: MIDDLE SCHOOL RESTROOM RENOVATION
PROJECT SCOPE (DOES NOT ALTER EXISTING LIFE SAFETY OR EGRESS PLAN)
CODE PARAMETERS
GENERAL NOTES CONTINUED
27. THE CONTRACTOR SHALL VERIFY AND COORDINATE, WITH ALL
TRADES, THE SIZES AND LOCATIONS OF ALL OPENINGS FOR
MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT
PADS, OR BASES AS WELL AS POWER, WATER, AND DRAIN
INSTALLATIONS BEFORE PROCEEDING WITH WORK. ALL CONCERNS,
SPACE LIMITATIONS OR STRUCTURAL CONFLICTS SHALL BE BROUGHT
TO THE IMMEDIATE ATTENTION OF THE OWNER REPRESENTATIVE,
PRIOR TO COMMENCING WITH THE WORK IN QUESTION.
28. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND
LOCATE ELECTRICAL, DATA AND PHONE RECEPTACLES, SWITCHES,
ETC. TO AVOID CONFLICTS WITH CASEWORK, DOORS, AND OTHER
TRADES.
DEMOLITION (APPLIES TO ALL DEMOLITION DRAWINGS)
1. DRAWINGS OF THE EXISTING BUILDING HAVE BEEN PREPARED
FROM A COMBINATION OF EXISTING DRAWING INFORMATION
AND SPOT FIELD MEASUREMENTS.
2. UNLESS OTHERWISE NOTED, REMOVAL OF EXISTING
CONSTRUCTION ON DEMOLITION PLANS IS INDICATED BY A
DASHED LINES. EXISTING CONSTRUCTION TO REMAIN IS
INDICATED BY SOLID LINES.
3. DEMOLITION KEYNOTES AND THE DRAWINGS ARE INTENDED TO
PROVIDE A GENERAL INDICATION OF WORK TO BE REMOVED. IT
IS NOT INTENDED THAT THE DRAWINGS INDICATE EACH AND
EVERY ITEM OF DEMOLITION AND PATCHING REQUIRED TO
COMPLETE THE WORK.
4. DEMOLITION AND PATCHING SHALL BE PERFORMED AS
NECESSARY TO COMPLETE THE WORK INDICATED, REGARDLESS
OF WHETHER THE WORK IS SPECIFICALLY NOTED ON THE
DRAWINGS. UNLESS A DEMOLITION NOTE IS SPECIFICALLY
NOTED TO BE LIMITED TO A SPECIFIC ITEM OF WORK, IT SHALL
BE ASSUMED THAT THE NOTE APPLIES TO THE ENTIRE AREA.
QUANTITIES OF WORK, IF INDICATED, ARE ESTIMATES. NO CLAIM
FOR A CHANGE IN THE CONTRACT WILL BE CONSIDERED
UNLESS THE ACTUAL SCOPE OF WORK DIFFERS SUBSTANTIALLY
FROM WHAT IS INDICATED.
5. REFER TO THE ALL DISCIPLINES DRAWINGS, INCLUDING
PLUMBING, MECHANICAL AND ELECTRICAL FOR OTHER
DEMOLITION REQUIREMENTS. PERFORM ARCHITECTURAL
DEMOLITION AS IS NECESSARY TO COMPLETE THE WORK
SHOWN ON OTHER DRAWINGS.
6. PATCH ALL OPENINGS IN EXISTING CONSTRUCTION, INCLUDING
PARTITIONS, FLOORS, CEILINGS, AND EXTERIOR WALLS,
RESULTING FROM THE REMOVAL OF PIPE, CONDUIT,
DUCTWORK, AND SIMILAR MISCELLANEOUS ITEMS, WITH
MATERIALS MATCHING EXISTING ADJACENT CONSTRUCTION.
OPENINGS IN EXISTING CONSTRUCTION INDICATED TO BE FIRE
RATED SHALL BE PATCHED AND SEALED WITH MATERIALS
MATCHING EXISTING CONSTRUCTION AND WHICH PROVIDE THE
EQUIVALENT FIRE RESISTANCE RATING INDICATED ON THE
DRAWINGS.
7. PROTECT THE EXISTING FACILITIES AT ALL TIMES DURING THE
COURSE OF CONSTRUCTION. ALL DAMAGES CAUSED, AS A
RESULT OF CONTRACTOR ACTIVITIES, SHALL BE REPAIRED AT
NO ADDITIONAL COST.
8. IN GENERAL, PATCHING, REPAIR, REMODELING, AND
RENOVATION WORK SHALL TO MATCH, COMPLIMENT AND ALIGN
WITH EXISTING CONDITIONS.
9. WHERE FULL OR PARTIAL DEMOLITION OF A BUILDING ELEMENT
IS INDICATED, REMOVAL OF ALL ITEMS ATTACHED TO OR
CONTAINED WITHIN THE ELEMENT OR PORTION OF ELEMENT TO
BE DEMOLISHED SHALL BE INCLUDED IN THE DEMOLITION OF
THE BUILDING ELEMENT EVEN IF NOT NOTED SPECIFICALLY.
ITEMS THAT MAY BE ATTACHED TO, OR CONTAINED WITHIN, THE
BUILDING ELEMENT, OR PORTION OF THE BUILDING ELEMENT TO
BE DEMOLISHED MAY INCLUDE BUT ARE NOT LIMITED TO
CONDUIT, WIRING, SWITCHES, RECEPTACLES, JUNCTION BOXES,
PIPING, DUCTWORK, GRILLES, DIFFUSERS, LOUVERS,
INSULATION, FURRING, BASE, FINISHES, TRIMS, DOORS, DOOR
FRAMES, DOOR HARDWARE, TRANSOMS, WINDOWS, WINDOW
FRAMES, WINDOW HARDWARE, TOILET ACCESSORIES, CHALK
BOARDS, TACK BOARDSAND ANCHORS ASSOCIATED WITH
ATTACHED ITEMS.
1. CONSTRUCTION SHALL CONFORM TO ALL GOVERNING CODES.
2. FIRST FLOOR FINISH FLOOR ELEVATION OF 0'-0" IS FOR REFERENCE
ONLY. FINISH FLOOR OF NEW CONSTRUCTION CORRESPONDS
WITH ACTUAL FINISH FLOOR ELEVATIONS AS SHOWN ON CIVIL SITE
PLAN.
3. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION THE
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING
CLARIFICATION FROM THE ARCHITECT OR ENGINEER OF RECORD
BEFORE CONTINUING WITH THE WORK.
4. EACH CONTRACTOR IS RESPONSIBLE FOR COORDINATING THEIR
WORK WITH ALL SURROUNDING CONSTRUCTION ELEMENTS AND
TRADES AFFECTED.
5. EACH CONTRACTOR IS RESPONSIBLE FOR CREATING AND PATCHING
ALL NEW OPENINGS, PENETRATIONS, LINTELS, ETC. AS REQUIRED
TO PERFORM THEIR PORTION OF WORK. AT NEW FIRE RATED
PARTITIONS, CLOSE OPENINGS/PENETRATIONS/ETC/ WITH
FIRESTOPPING THAT MATCHES OR EXCEEDS THE PARTITION
RATING.
6. ALL ITEMS REQUIRING COLOR SELECTION SHALL BE SELECTED BY
THE OWNER'S REPRESENTATIVE DURING THE SUBMITTAL REVIEW
FROM MANUFACTURER'S STANDARD OR FULL RANGE (AS
DIRECTED IN SPECIFICATION) OF COLORS.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY FOR THE COORDINATION
OF ALL DRAWINGS AND SPECIFICATIONS AS REQUIRED TO
PERFORM THE WORK AS CALLED FOR, SHOWN AND REASONABLY
IMPLIED.
8. ASBESTOS CONTAINING MATERIALS SHALL NOT BE USED ON ANY
PROJECT.
9. FINISH AND PAINT WALLS AND INSTALL FLOORING BEFORE
INSTALLING CASEWORK, EQUIPMENT, FIXTURES, ELEC. PANELS,
BOXES, SURFACE CONDUIT, ETC. IF APPLICABLE.
10. CONTRACTOR TO INSTALL WOOD OR METAL BLOCKING FOR ALL
CASEWORK, EQUIPMENT, HANDRAILS, BATH ACCESSORIES,
FIXTURE, ETC. AS RECOMMENDED BY MANUFACTURER, IF NOT
OTHERWISE SHOWN HEREIN.
11. ALL WOOD BLOCKING LOCATED OUTSIDE THE BLDG. ENVELOPE, IN
EXTERIOR WALLS/ROOFS OR IN CONTACT W/CONCRETE OR
MASONRY, SHALL BE FIRE RETARDANT TREATED LUMBER, AND
FASTENED WITH SCREWS. ALL TREATED WOOD BLOCKING SHALL
HAVE CORROSION RESISTANT SCREWS.
12. IF DISCREPANCIES BETWEEN PLANS OR SPECIFICATIONS OCCUR
THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OR ENGINEER OF
RECORD. TREAT ANYTHING MENTIONED IN THE SPECIFICATIONS
BUT NOT SHOWN ON THE DRAWINGS OR SHOWN ON THE DRAWINGS
BUT NOT INCLUDED IN THE SPECIFICATIONS AS IF SHOWN OR
MENTIONED IN BOTH. IF DISCREPANCIES OCCUR BETWEEN THE
DRAWINGS AND SPECIFICATIONS, THE SPECIFICATIONS TAKE
PRECEDENCE.
13. FOR INSTALLATION OF ALL WORK WHICH IS DEPENDENT ON
CONDITION OF SUBSTRATE, CAREFULLY INSPECT AND VERIFY
SUITABILITY OF SUBSTRATE FOR INSTALLATION OF WORK. DO NOT
INSTALL WORK OVER UNSUITABLE OR UNACCEPTABLE
SUBSTRATES. CORRECT UNACCEPTABLE SUBSTRATES BEFORE
INSTALLING WORK. CONTRACTOR IS RESPONSIBLE FOR ALL
GRINDING, LEVELING, SANDING, PATCHING ETC. TO CORRECT ALL
EXISTING SURFACES TO PREPARE FOR NEW FINISHES.
DEMOLITION GENERAL NOTES GENERAL NOTES
10. REMOVE MECHANICAL, ELECTRICAL AND PLUMBING ITEMS IN
ACCORDANCE WITH MECHANICAL, ELECTRICAL AND
PLUMBING DOCUMENTS.
11. WHERE A WALL OR A BUILDING ELEMENT IS INDICATED TO BE
DEMOLISHED, CLEAN AND REPAIR RESULTING DAMAGE TO
THE FLOOR SUBSTRATE. GRIND AND/OR FILL AND PATCH
DAMAGED AREAS OF THE EXISTING FLOOR SUBSTRATE WITH
A CONCRETE TOPPING SLAB OR A CEMENTITIOUS LEVELING
COMPOUND AS APPLICABLE.
12. WHERE A WALL OR PORTION OF A MASONRY OR CONCRETE
WALL IS INDICATED TO BE DEMOLISHED, GRIND AND REPAIR
THE ADJOINING MASONRY OR CONCRETE WALL SURFACES.
GRIND SURFACES SMOOTH AND PATCH DAMAGED AREAS OF
THE ADJOINING WALL AREAS WITH NON-SHRINK GROUT.
CLEAN AND PREPARE EXISTING AND PATCHED WALL
SURFACES TO RECEIVE THE FINISH INDICATED.
13. MISCELLANEOUS ITEMS WHICH ARE NOT SPECIFICALLY
SHOWN ON THE DRAWINGS SHALL BE REMOVED IN
RENOVATED AREAS, UNLESS OTHERWISE INDICATED OR
DIRECTED BY THE OWNER. MISCELLANEOUS ITEMS INCLUDE
BUT ARE NOT LIMITED TO FIRE EXTINGUISHERS, CLOCKS,
TOILET ACCESSORIES, BRACKETS HANGERS BOLTS, PLATES
BLOCKING, ETC. REFER QUESTIONABLE ITEMS TO THE
ARCHITECT FOR VERIFICATION.
14. COORDINATE ALL DEMO WITH SECTION 01 74 19
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL.
15. FOR ELEMENTS INDICATED TO MATCH EXISTING, DOCUMENT
EXISTING CONDITIONS WITH DETAILED DRAWINGS,
DIMENSIONS, PHOTOGRAPHS, AND OTHER METHODS
NECESSARY TO MEMORIALIZE EXISTING CONDITIONS PRIOR
TO AND DURING DEMOLITION. COORDINATE WITH NEW
CONSTRUCTION DRAWINGS TO DETERMINE THE SCOPE OF
ELEMENTS TO MATCH EXISTING.
16. COORDINATE EXTENT OF TILE SETTING BED DEMOLITION
WITH REQUIREMENTS FOR NEW SETTING BED. DO NOT OVER
DEMOLISH IF UNNECESSARY PER TCNA.
14. MOUNTING HEIGHTS OF ELECTRICAL, PLUMBING, MECHANICAL, AND
OTHER DEVICES SHALL COMPLY WITH HEIGHTS INDICATED ON
DRAWINGS. NOTIFY ARCHITECT OR ENGINEER OF RECORD IF
CONFLICTS ARE ENCOUNTERED.
15. ALL EXPOSED METAL, METAL DECK, STRUCTURAL, BAR JOISTS,
CONDUITS, PIPES, ANGLES, BRACKETS, DUCT, ATC. SHALL NOT BE
PAINTED UNLESS NOTES OTHERWISE.
16. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS IN THE FIELD PRIOR TO ORDERING OR FABRICATION
OF MATERIALS OR THE BEGINNING OF CONSTRUCTION. NOTIFY
ARCHITECT OR ENGINEER OR RECORD OF ALL DISCREPANCIES. ALL
WORK REQUIRING MEASURING TO BE DONE ACCORDING TO
FIGURES ON DRAWINGS. DISCREPANCIES BETWEEN ACTUAL
CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT OR ENGINEER OF
RECORD. CONTRACTOR TO SUBMIT SPECIFIC DISCREPANCY FOR
ARCHITECT OR ENGINEER OF RECORD REVIEW, PRIOR TO
COMMENCING WITH THE WORK IN QUESTION.
17. CONTRACTOR TO REVIEW ALL DRAWINGS ISSUED FOR THIS
PROJECT FOR ADDITIONAL INFORMATION FROM OTHER TRADES
TO COORDINATE THE REQUIRED SCOPE OF WORK.
18. ALL MATERIALS, FIXTURE AND EQUIPMENT INDICATED IN THE
CONSTRUCTION DOCUMENTS SHALL BE NEW AND AS SPECIFIED,
UNLESS IDENTIFIED OTHERWISE.
19. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH,
CONTINUOUSLY FREE OF IMPERFECTIONS AND IMPROPER
CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS
SHALL MATCH THE ADJACENT MATERIALS CONSTRUCTION AND
FINISH.
20. ALL FLOORS ON EITHER SIDE OF DOORWAY OR OPENING SHALL BE
LEVEL AND HAVE MAXIMUM ELEVATION DIFFERENCE OR
THRESHOLD HEIGHT OF 1/2"
21. ALL NEW PENETRATIONS OF FIRE RATED FLOORS, WALLS AND
CEILING TO BE SEALED WITH PROPER APPROVED MATERIALS TO
THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS.
22. FIRE STOP ALL NEW WALLS AND CEILING AS REQUIRED BY
APPLICABLE CODE.
23. ALL NEW WOOD BLOCKING IN EXTERIOR WALLS TO BE MOISTURE
RESISTANT TREATED IN ACCORDANCE WITH SPECIFICATIONS.
WHERE REQUIRED BY CODE, ALL NEW WOOD BLOCKING IN INTERIOR
WALLS TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH
SPECIFICATIONS.
24. INSTALL SEALANT AT EXTERIOR SIDE OF ALL NEW JOINTS, SEAMS,
CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR
AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT
COLOR TO MATCH ARCHITECT'S SAMPLE. COLOR REQUIRES
ARCHITECT'S APPROVAL.
25. PROVIDE FIRE EXTINGUISHERS COMPLYING WITH NFOA 10, AS
INDICATED ON LIFE SAFETY DRAWINGS.
26. THE CONTRACTOR HAS THE RESPONSIBLY TO VERIFY UTILITY
LOCATIONS IN THE FIELD BY EMPLOYING FIELD UTILITY LOCATING
SERVICES BEFORE CONSTRUCTION STARTS, AND COORDINATE
ALL NEW UTILITY LOCATIONS, CONNECTIONS AND PENETRATIONS.
Lic. No. 0401014032
09/02/2025
09/02/2025
09/02/2025
100% BID
DOCUMENTS
100% BID
DOCUMENTS
Strelitz Text Box
100% BID DOCUMENTS
APPLICABLE CODES AND STANDARDS
• VIRGINIA CONSTRUCTION CODE (VCC) (2021)
• VIRGINIA STATEWIDE FIRE PREVENTION CODE (2021)
• ICC A117.1, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (2017)
• NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES (2016)
SUMMARY OF FIRE PROTECTION FEATURES
THIS PROJECT INCLUDES THE FOLLOWING FIRE PROTECTION FEATURES:
• FIRE-RESISTANCE RATED CONSTRUCTION
TYPE OF CONSTRUCTION
VCC CHAPTER 6
BUILDING CONSTRUCTION TYPE IS EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT
SCOPE OF WORK.
FIRE-RESISTANCE RATED BUILDING COMPONENTS
VCC TABLE 601
FIRE RESISTANCE REATED BUILDING COMPONENTS ARE EXISTING TO REMAIN AND WILL NOT BE
ALTERED UNDER THIS PROJECT SCOPE OF WORK.
HEIGHT LIMITATIONS
VCC SECTION 503 AND 504
BUILDING HEIGHT IS EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT
SCOPE OF WORK.
BUILDING SEPARATION AND EXPOSURE PROTECTION
VCC TABLE 602, TABLE 705.8
BUILDING SEPARATION AND EXPOSURE PROTECTION ARE EXISTING TO REMAIN AND WILL NOT BE
ALTERED UNDER THIS PROJECT SCOPE OF WORK.
REQUIRED INTERIOR SEPARATIONS
VCC CHAPTER 7 AND CHAPTER 10
DURING SITE INVESTIGATIONS IT WAS NOTED THAT THE EXISTING SHOWER ROOMS ARE BEING UTILIZED
AS STORAGE ROOMS FOR MISCELANEOUS STORAGE. WITH THIS BUILDING NOT PROTECTED
THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM, THE SHOWER ROOMS WOULD BE
REQUIRED TO BE 1-HOUR FIRE RESISTANCE RATED IN ORDER FOR THE THESE ROOMS TO REMAIN AS A STORAGE ROOM. REFER TO LIFE SAFETY PLAN FOR SHOWER ROOMS THAT WILL REQUIRE THE 1-HOUR
FIRE RESISTANCE RATING.
CLASSIFICATION OF OCCUPANCY
VCC CHAPTER 3
THIS EXISTING FACILITY IS CLASSIFIED AS A SINGLE USE OCCUPANCY:
• EDUCATIONAL GROUP E
UTILITY, SUPPORT, AND STORAGE AREAS ARE ACCESSORY TO THE PRIMARY OCCUPANCY AND THEIR COMBINED AREA IS LESS THAN 10% OF THE FLOOR AREA OF THE STORY IN WHICH THEY ARE LOCATED.
ASSEMBLY SPACES ARE CONSIDERED ASSOCIATED WITH THE EDUCATIONAL OCCUPANCY AND ARE
PERMITTED TO BE INCLUDED IN THE EDUCATIONAL GROUP E CLASSIFICATION PER VCC 303.1.3.
AREA LIMITATIONS
VCC SECTION 506
BUILDING AREA EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT
SCOPE OF WORK..RESTROOM RENOVATION WILL NOT INCREASE THE TOTAL ARE OF THE
BUILDING.
VERTICAL OPENINGS
VERTICAL OPENINGS WILL NOT BE CREATED UNDER THIS PROJECT SCOPE OF WORK.
INTERIOR FINISH REQUIREMENTS
VCC TABLE 803.11, SECTION 804
INTERIOR FINISH IS REQUIRED TO COMPLY WITH THE CRITERIA FOR EDUCATIONAL OCCUPANCY THAT IS
NOT PROTECTED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM.
COMPONENT INTERIOR FINISH FLOOR FINISH
EXITS A I OR II
EXIT ACCESS CORRIDORS A OR B I OR II
OTHER SPACES A, B, OR C NOT APPLICABLE
FOR INTERIOR FINISH:
CLASSIFICATION FLAME SPREAD INDEX SMOKE DEVELOPMENT INDEX
CLASS A 0 - 25 0 - 450
CLASS B 26 - 75 0 - 450
CLASS C 76 - 200 0 - 450
FOR FLOOR FINISH:
CLASSIFICATION CRITICAL RADIANT FLUX
CLASS I >0.45 W/SQ.CM
CLASS II 0.22 - 0.45 W/SQ.CM
VCC CHAPTER 10
RENOVATION TO THE EXISTING RESTROOMS WILL NOT INCREASE OR DECREASE THE OCCUPANT LOAD.
OCCUPANT LOAD
NUMBER OF EXITS
VCC CHAPTER 10
MINIMUM NUMBER OF EXITS ARE EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT
SCOPE OF WORK.
EXIT CAPACITY AND EXIT WIDTH
VCC CHAPTER 10
EXIT CAPACITY AND EXIT WIDTH ARE EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS
PROJECT SCOPE OF WORK.
EGRESS ARRANGEMENT
VCC CHAPTER 10
FOR AN EXISTING BUILDING NOT PROTECTED THROUGHOUT BY AN AUTOMATIC FIRE SPRINKLER SYSTEM:
USE TRAVEL DISTANCE COMMON PATH DEAD END CORRIDOR
EDUCATIONAL 200 FT (MAX) 75 FT (MAX) 20 FT (MAX)
STORAGE 200 FT (MAX) 75 FT (MAX) 20 FT (MAX)
MEANS OF EGRESS ILLUMINATION
VCC CHAPTER 10
MEANS OF EGRESS ILLUMINATION IS REQUIRED.
SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
EMERGENCY LIGHTING
VCC CHAPTER 10
EMERGENCY LIGHTING IS REQUIRED FOR A MINIMUM OF 90-MINUTES.
SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
MEANS OF EGRESS MARKING
VCC CHAPTER 10
ILLUMINATED EXIT SIGNAGE IS REQUIRED AT EXITS AND DIRECTIONAL EXIT SIGNAGE REQUIRED ALONG
THE PATH OF EGRESS TRAVEL. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
FIRE DEPARTMENT VEHICLE ACCESS
VCC SECTION 503
FIRE DEPARTMENT VEHICLE ACCESS IS EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS
PROJECT SCOPE OF WORK.
RESPONDING PERSONNEL ACCESS
VCC SECTION 504 AND 506
RESPONDING PERSONNEL ACCRSS IS EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS
PROJECT SCOPE OF WORK.
VCC AND NFPA 13
THE EXISTING MUNICIPAL UNDERGROUND WATER DISTRIBUTION SYSTEM WILL NOT BE ALTERED UNDER
THIS PROJECT SCOPE OF WORK.
WATER SUPPLY
CALCULATED FIRE-FLOW
VIRIGINIA STATEWIDE FIRE PREVENTION CODE, APPENDIX B
BUILDING CALCULATED FIRE FLOW IS EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS
PROJECT SCOPE OF WORK.
FIRE HYDRANTS
VIRGINIA STATEWIDE FIRE PREVENTION CODE, SECTION 507.5
FIRE HYDRANTS ARE EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT SCOPE OF
WORK.
STANDPIPE SYSTEM
VCC SECTION 410.7, 905.3.4 AND NFPA 14
THE EXISTING BUILDING IS NOT PROTECTED BY A STANDPIPE SYSTEM AND IS NOT REQUIRED NOR
PROVIDED UNDER THIS PROJECT SCOPE OF WORK
PORTABLE FIRE EXTINGUISHERS
VCC SECTION 906 AND NFPA 10
FIRE EXTINGUISHERS ARE EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT
SCOPE OF WORK.
VCC 907.2.3 AND NFPA 72
AN EXISTING FIRE DETECTION AND ALARM SYSTEM IS PROVIDED FOR THE BUILDING. EXISTING FIRE ALARM OCCUPANT NOTIFICATION APPLIANCES ARE PROVIDED FOR SOME OF THE EXISTING RESTROOMS
THAT ARE BEING RENOVATED. THESE APPLIANCES WILL BE REVIEWED FOR CODE COMPLIANCE
RELATING TO LOCATION, ROOM SIZE AND CANDELA RATING OF THE APPLIANCE. WHERE EXISTING RESTROOMS BEING RENOVATED DO NOT HAVE FIRE ALARM OCCUPANT NOTIFICATION APPLIANCES, EACH RESTROOM WILL BE REVIEWED AS TO THE CODE REQUIREMENT FOR PROVIDING NEW FIRE ALARM
OCCUPANT NOTIFICATION APPLIANCES.
FIRE DETECTION AND ALARM SYSTEM
N/A - ELEVATOR IS NOT PROVIDED IN THIS BUILDING.
ELEVATOR EMERGENCY OPERATION AND PROTECTION
AREA OF RESCUE ASSISTANCE TWO-WAY COMMUNICATION
NOT APPLICABLE - NO EQUIVALENCIES REQUESTED.
APPROVED EQUIVALENCIES
BUILDING AREA SEPARATION
VCC 503, 504, 506, 706
BUILDING AREA SEPARATIONS ARE EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS PROJECT
SCOPE OF WORK.
VCC AND NFPA 13
THE EXISTING BUILDING IS NOT PROTECTED BY AN AUTOMATIC FIRE SPRINKLER SYSTEM AND IS
NOT REQUIRED NOR PROVIDED UNDER THIS PROJECT SCOPE OF WORK
AUTOMATIC FIRE SUPPRESSION SYSTEMS
INCIDENTAL USE AREAS
REQUIRED SEPARATIONS OF EXITS
VCC 1007
REQUIRED SEPARATION OF EXITS ARE EXISTING TO REMAIN AND WILL NOT BE ALTERED UNDER THIS
PROJECT SCOPE OF WORK.
VCC 904
N/A - NO SPECIAL SUPPRESSION SYSTEMS REQUIRED UNDER THIS PROJECT SCOPE OF WORK.
SPECIAL SUPPRESSION SYSTEMS
N/A - ELEVATOR IS NOT PROVIDED IN THIS BUILDING.
VCC 509
THERE WILL BE NO NEW INCIDENTAL USES CREATED UNDER THIS PROJECT SCOPE OF WORK.
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
757.417.0140
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
S
U A
N C
E S
C H
E D
U
DATE ISSUED:
N U
M B
S C
R
IP
T
DRAWN BY:
CHECKED BY:
A ut od es k D oc s:
//P or ts m ou th
P ub lic S ch oo ls
H ub
_R
W
_L S
_W at er s
M S
A D
A R
R R en ov at io n_ R
.r vt
8/
/2
6:
:4
A
M
CODE SUMMARY
GI001
P.BUTT
J.ZIMMERMAN
P.BUTT
10012314.07
09/02/2025
W A
T E
R S
M
ID
D L
E S
C H
O O
L C
IT
Y
O F
P O
R T
S M
O U
T H
R O
O S
E V
E
LT
R D
P O
R T
S M
O U
T H
, V A
A D
A R
E S
T R
O O
M R
E N
O V
A T
IO
N
S
Lic. No. 0401014032
09/02/2025
09/02/2025
100% BID
DOCUMENTS
100% BID
DOCUMENTS
GIRLS TLT
TLT
GIRLS
LOCKER
STORAGE
257STORAGE
TLT
155.B
TLT
TLT
GIRLS TLT
TLT
116A
BOYS TLT
STAFF TLT
STAFF TLT
KITCHEN
STAFF
TOILET
TLT
TLT
TLT
247 BOYS
LOCKER
ROOM
STORAGE
TLT
TLT
BOYS TLT
NOT IN
S
COPE O
F W
ORK
NOT IN
S
COPE O
F W
ORK
NOT IN
S
COPE O
F W
ORK
NOT IN
S
COPE O
F W
ORK
NOT IN
S
COPE O
F W
ORK
NOT IN
S
COPE O
F W
ORK
EXIT
A229
EXIT
A130
EXIT
A131
EXIT
A132
EXIT
A133
EXIT
A253
EXIT
A125
EXIT
A124
EXIT
A123
EXIT
A122
EXIT
A126
EXIT
A127
EXIT
A128
EXIT
A129
EXIT
A245
EXIT
A243
125'
TD
CORRIDOR
CORRIDOR
CORRIDOR
58'
TD
193'
TD
169'
TD
141'
TD
150'
TD
88'
TD
170'
TD
155'
TD
143'
TD
141'
TD
150'
TD
144'
TD
88'
TD
73'
TD
169'
TD
193'
TD
63'
TD
55'
TD
61'
TD
58'
TD
66'
TD
LIFE SAFETY LEGEND
1-HOUR FIRE BARRIER
• 45-MIN RATED OPENING PROTECTIVES
(DOORS AND WINDOWS)
• DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
• FIRE DAMPERS NOT REQUIRED FOR
DUCTED SYSTEMS
• 1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
XXX EXIT IDENTIFIER
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
757.417.0140
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
S
U A
N C
E S
C H
E D
U
DATE ISSUED:
N U
M B
S C
R
IP
T
DRAWN BY:
CHECKED BY:
A ut od es k D oc s:
//P or ts m ou th
P ub lic S ch oo ls
H ub
_R
W
_L S
_W at er s
M S
A D
A R
R R en ov at io n_ R
.r vt
8/
/2
6:
:4
A
M
LIFE SAFETY PLAN - FIRST
FLOOR
GI101
P.BUTT
J.ZIMMERMAN
P.BUTT
10012314.07
09/02/2025
W A
T E
R S
M
ID
D L
E S
C H
O O
L C
IT
Y
O F
P O
R T
S M
O U
T H
R O
O S
E V
E
LT
R D
P O
R T
S M
O U
T H
, V A
A D
A R
E S
T R
O O
M R
E N
O V
A T
IO
N
S
SCALE : 1/16" = 1'-0"A1
LIFE SAFETY PLAN - FIRST FLOOR
EGRESS ARRANGEMENT - FIRST FLOOR
MARK LENGTH FROM ROOM TO ROOM
TD 125' - 0" GIRLS TLT 201 CORRIDOR 262
TD 65' - 9" BOYS TLT 178 CORRIDOR 262
TD 63' - 2" TLT 273 MECHANICAL ROOM 270
TD 57' - 11" TLT 247 BOYS LOCKER ROOM 248
TD 73' - 1" BOYS TLT 128 CORRIDOR 262
TD 144' - 2" GIRLS TLT 108 CORRIDOR 262
TD 87' - 6" TLT 116B CORRIDOR 262
TD 140' - 11" TLT 155.B CORRIDOR 263
TD 149' - 8" TLT 159 CORRIDOR 263
TD 169' - 2" TLT 134 CORRIDOR 135
TD 193' - 3" TLT 197 CORRIDOR 135
TD 169' - 7" STAFF TLT 214 CORRIDOR 262
TD 154' - 11" STAFF TLT 213 CORRIDOR 262
TD 143' - 6" KITCHEN STAFF TOILET 233 CORRIDOR 262
TD 61' - 3" TLT 265 GIRLS LOCKER 259
TD 55' - 0" TLT 261 GIRLS LOCKER 259
OCCUPANT LOAD - FIRST FLOOR
ROOM NO. ROOM NAME SPACE USE & LF
AREA
(APPROX.)
OCCUPANCY
LOAD FACTOR
OCCUPANT
LOAD
108 GIRLS TLT RESTROOMS 319 SF 0
116A TLT RESTROOMS 35 SF 0
128 BOYS TLT RESTROOMS 328 SF 0
134 TLT RESTROOMS 67 SF 0
135 CORRIDOR (none) 1788 SF
155.B TLT RESTROOMS 66 SF 0
159 TLT RESTROOMS 29 SF 0
178 BOYS TLT RESTROOMS 320 SF 0
197 TLT RESTROOMS 51 SF 0
201 GIRLS TLT RESTROOMS 322 SF 0
213 STAFF TLT RESTROOMS 44 SF 0
214 STAFF TLT RESTROOMS 44 SF 0
233 KITCHEN STAFF TOILET RESTROOMS 115 SF 0
242 TLT RESTROOMS 26 SF 0
247 TLT RESTROOMS 48 SF 0
248 BOYS LOCKER ROOM RESTROOMS 1525 SF 0
251 TLT RESTROOMS 107 SF 0
253 STORAGE STORAGE
(GENERAL)
253 SF 0
256 STORAGE STORAGE
(GENERAL)
269 SF 0
257 STORAGE STORAGE
(GENERAL)
167 SF 0
259 GIRLS LOCKER RESTROOMS 1527 SF 0
261 TLT RESTROOMS 99 SF 0
262 CORRIDOR CIRCULATION 10798 SF 0
263 CORRIDOR CIRCULATION 1823 SF 0
265 TLT RESTROOMS 43 SF 0
273 TLT RESTROOMS 15 SF 0
TOTAL 0
A
B
C
D
E
F
KEY PLAN
0 4' 8' 16' 32' 48'
1/16"=1'-0"
NOTE: EXISTING BUILDING OCCUPANCY TO REMAIN UNCHANGED. RESTROOM RENOVATIONS WILL NOT INCREASE OR DECREASE
OCCUPANT LOAD.
Lic. No. 0401014032
09/02/2025
09/02/2025
100% BID
DOCUMENTS
A-402 D5
A-401 A4
A-401 A1
A-403 C1
A-403 A1
A-401 C5
A-402 A1
A-402 C1
A-403 F1
A-402 B5
A-402 E1
A-401 E1 A-402
A5
N
O
I
S
C
O
P
F
W
R
K
N
O
R
K
N
O
R
K
N
O
R
K
N
O
R
K
N
O
R
K
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
SU
AN
CE
S
CH
ED
UL
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
NOT FOR
CONSTRUCTION
NU
M
BE
AT
ES
CR
IP
TI
O
N
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PRELIMINARY
FIRST FLOOR OVERALL
PLAN - HAZMAT
REMOVAL
HM101
W. PINE
H. ADCOCK
W. PINE
10012314.07 07/11/25
W
AT
ER
S
M
ID
DL
E
SC
HO
O L
CI
TY
O F
PO
RT
SM
O
UT
H
RO
O
SE
VE
LT
R
D
PO
RT
SM
O
UT
H, V
A
AD
A
RE
ST
RO
O
M R
EN
O
VA
TI
O
NS
1/16" = 1'-0"
OVERALL FLOOR PLAN - HAZMAT REMOVAL
KEY PLAN
C F
E B
A D
0 4' 8' 16' 32' 48' 1/16"=1'-0"
GRAPHIC SCALE
1. A HAZARDOUS MATERIALS INSPECTION WAS PERFORMED. THE SURVEY/INSPECTION REPORT IS PROVIDED IN THE SPECIFICATIONS/CONTRACT DOCUMENTS. THE WORK WILL REQUIRE THE REMOVAL OF KNOWN ASBESTOS-CONTAINING MATERIALS (ACM). DESTRUCTIVE ACTIVITIES SUCH AS BREAKING INTO WALLS, CEILINGS AND FLOORS WERE NOT PERFORMED IN ORDER TO LOCATE MATERIALS. THEREFORE, IF DURING THE WORK SUSPECT MATERIALS ARE UNCOVERED, NOTIFY THE CONTRACTING OFFICER AND STOP WORK UNTIL THE MATERIAL IS PROPERLY IDENTIFIED
AND ADDRESSED.
2. THE CONTRACT DOCUMENTS REPRESENT CONDITIONS WITHIN THE FACILITY AT THE TIME OF THE INITIAL FIELD INVESTIGATION. REFER TO REPORT TO DETERMINE THOSE CONDITIONS. SHOULD CONDITIONS EXISTS OTHER THAN THOSE INDICATED IN THE REPORT, CONSULT THE
CONTRACTING OFFICER FOR VERIFICATION.
3. CONTRACTOR MUST VISIT THE SITE TO ASCERTAIN THE EXACT NATURE AND LOCATION OF THE WORK INCLUDING THE WORK OR COST THEREOF.
4. CONTRACTOR MUST COORDINATE ALL ASPECTS OF THE WORK WITH OTHER TRADES. SEE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND
ELECTRICAL DEMOLITION DRAWINGS.
5. THE AHERA DOCUMENT IDENTIFIED ACM PIPE FITTING INSULATION IN PIPE CHASES . CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN EXPOSING CONCEALED AREAS BECAUSE ACM PIPE INSULATION, MUDDED FITTINGS MAY BE ENCOUNTERED.
6. REMOVE ACM IN ACCORDANCE WITH SPECIFICATION SECTION 02 82 00 "ASBESTOS REMEDIATION." FOR BIDDING PURPOSES ASSUME THE FOLLOWING ESTIMATED ACM QUANTITIES: (A) MUDDED MATERIAL PIPE FITTINGS (100 EACH), (B) DOOR FRAME SEALANT (200 LINEAR FEET), (C)
SINK WITH ACM UNDERSINK MASTIC (1 EACH).
7. EXISTING PAINT WITHIN THE STRUCTURE HAS BEEN DETERMINED TO CONTAIN CONCENTRATIONS ABOVE THE LABORATORY'S MINIMUM DETECTION LIMIT OF THE FOLLOWING METALS: LEAD, CADMIUM AND CHROMIUM. EXTERIOR PAINTED SURFACES ARE LEAD-BASED PAINT.
PERFORM RENOVATION WORK IN ACCORDANCE WITH SPECIFICATION SECTION 02 83 00 "LEAD REMEDIATION". CONSTRUCTION STANDARDS ESTABLISHED BY OSHA FOR CHROMIUM, CADMIUM AND LEAD ARE; CHROMIUM, 29 CFR 1926.1126; CADMIUM, 29 CFR 1926.1127 AND LEAD, 29 CFR 1926.62
8. TOXICITY CHARACTERISTIC LEACHING PROCEDURE (TCLP) TESTING ON EXISTING PAINTED BUILDING MATERIALS, WHEN DEMOLISHED AS COMPONENTS OF AN ASSEMBLY TYPICALLY RETURN RESULTS CLASSIFYING THE WASTE AS NONHAZARDOUS. PAINTED MATERIAL REMOVED IN THE FORM OF STRIPPING, BLASTING, SCRAPING OR OTHER METHODS THAT REMOVE THE PAINT COATING FROM THE EXISTING SUBSTRATE, OR PRODUCES A WASTE RESULTING PRIMARILY OF PAINT MATERIAL, MAY RESULT IN WASTE CLASSIFIED AS HAZARDOUS. THE CONTRACTOR MUST COORDINATE THE WORK PROCEDURES TO CHARACTERIZE THE ANTICIPATED WASTE STREAM. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH CHARACTERIZATION AND DISPOSAL OF WASTE GENERATED FROM THE WORK. INCLUDE LEAD PAINT ABATEMENT EFFORTS FOR ALL WORK ITEMS AS NEEDED FOR THE PROJECT. COORDINATE WASTE DISPOSAL AND ACCUMULATION WITH INSTALLATION ENVIRONMENTAL
PRIOR TO WASTE GENERATION ACTIVITIES.
9. ALL LIGHT BALLASTS WITHOUT "NON PCB" MARKINGS AND ALL FLUORESCENT LIGHT TUBES MUST BE REMOVED IN ACCORDANCE WITH SPECIFICATION SECTION 02 84 16. FOR BIDDING PURPOSES, ASSUME 5 BALLASTS CONTAIN PCB's AND ALL FLUORESCENT LIGHT TUBES CONTAIN MERCURY VAPOR. COORDINATE WASTE DISPOSAL AND ACCUMULATION WITH INSTALLATION ENVIRONMENTAL PRIOR TO WASTE GENERATION
ACTIVITIES.
10. DISASSEMBLE, REMOVE, AND INSPECT DOORS TO BE REMOVED TO DETERMINE ASBESTOS CONTENT. THE INSPECTION MUST BE PERFORMED BY A VIRGINIA LICENSED ASBESTOS INSPECTOR. REMOVE, HANDLE, AND DISPOSE OF ASBESTOS DOORS IN ACCORDANCE WITH SPECIFICATION SECTION 02 82 00. NON-ASBESTOS DOORS MUST BE DISPOSED OF AS REGULAR CONSTRUCTION WASTE. FOR BIDDING PURPOSES, ASSUME 8
ASBESTOS-CONTAINING DOORS EXIST (TOTAL FOR PROJECT).
11. MANAGE ALL WASTE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS INCLUDING 40 CFR 261 AND 40 CFR 262. COMPLY
WITH ALL ENVIRONMENTAL REQUIREMENTS.
(HM101)
PHOTOGRAPH LOCATION.
KEY TO SYMBOLS
REFERENCE PHOTOGRAPH NOTES
1. VIEW OF TYPICAL STUDENT RESTROOM. NO ACM WAS DETECTED IN ANY INTERIOR FINISHES WITHIN THE STUDENT BATHROOMS.
2. VIEW OF PIPING SERVING A STUDENT RESTROOM. ACM MUDDED MATERIALS WERE IDENTIFIED WITHIN THE SCHOOL. ACM MUDDED PIPE FITTINGS
MAY EXIST ABOVE CEILINGS AND WITHIN WALLS AND CHASES.
3. VIEW OF TYPICAL SINGLE ADULT RESTROOM. NO MATERIALS WITHIN THE SINGLE RESTROOMS WERE DETERMINED TO BE ACM. ACM MUDDED
MATERIALS MAY STILL EXIST ABOVE CEILING OR IN WALLS AND CHASES.
4. VIEW OF THE SHARED SINGLE STUDENT RESTROOM BETWEEN CLASSROOMS. THIS RESTROOM HAS A METAL SINK WITH ACM UNDERSINK MASTIC.
HAZMAT GENERAL NOTES
HAZMAT KEY NOTES
1. REMOVE ACM MUDDED PIPE FITTING INSULATION AS REQUIRED TO PERFORM WORK. THE MATERIAL MAY BE ABOVE
CEILINGS, IN CONCEALED AREAS AND IN CHASES.
2. REMOVE DOOR FRAME SEALANT AS REQUIRED TO PERFORM THE WORK. REMOVE AND INSPECT DOOR FOR ACM, SEE HAZMAT
GENERAL NOTE #10 ON HM101.
3. REMOVE SINK, WITH ACM UNDERSINK MASTIC.
(HM101)
(HM101)
(HM101)
REFERENCE PHOTO - NOTE 1A1 HM101
REFERENCE PHOTO - NOTE 2A2 HM101
REFERENCE PHOTO - NOTE 3A3 HM101
REFERENCE PHOTO - NOTE 4A4 HM101
7/
/2
1:
P
M
M :\P
RO
JE
CT
S\
W at er s
M S
AD
A
Re st ro om
\D ra wi ng sG er
\9 5%
S ub m itt al D wg s
(1
C om pl et e)
\H
AZ
M
AT
_W at er s
M S
AD
A
RR
R en ov at io n
- S he et
H1
1S T
FL
O
O R
O
VE
RA
LL
P
LA
N
- H
AZ
M
AT
R
EM
O
VA
L.
dw g
CAUTION NOTE
DO NOT DISTURB ACM MUDDED PIPE FITTINGS AND
INSULATION UNLESS REQUIRED TO.
CAUTION NOTE
TERRAZZO FLOORING CONTAINS ASBESTOS.
DO NOT DISTURB ACM .
THESE HAZMAT KEYNOTES APPLY TO ALL SPACES TO BE RENOVATED
UNLESS OTHERWISE NOTED.
License # 3305001394
WYATT S. PINE
Asbestos Project
Designer
09/02/2025
A
B
C
D
E
F
KEY PLAN
100% BID
DOCUMENTS
1. COORDINATE AND VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL DRAWINGS AND THE DRAWINGS OF ALL OTHER
DISCIPLINES PRIOR TO STARTING CONSTRUCTION.
2. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, ELECTRICAL, FIRE PROTECTION, MECHANICAL, AND PLUMBING DRAWINGS (AS APPLICABLE) INCLUDING SPECIFICATIONS THAT COMPRISE THE COMPLETE CONSTRUCTION DOCUMENT SET FOR THIS PROJECT. THE CONTRACTOR SHALL COORDINATE AND VERIFY THE REQUIREMENTS OF ALL OTHER TRADES AS TO SLEEVES, CHASES, ANCHORS, INSERTS, HANGERS, HOLES, AND ANY
ADDITIONAL ITEMS TO BE PLACED IN THE STRUCTURAL WORK.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, SEQUENCES, REGULATIONS, AND
SAFETY MEASURES AS IT RELATES TO THIS PROJECT.
4. PROVIDE ALL TEMPORARY SHORING, GUYING AND BRACING TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK HAS BEEN COMPLETED. THE DESIGN OF SHORING, GUYING AND BRACING IS
THE RESPONSIBILITY OF THE CONTRACTOR.
5. EQUIPMENT WEIGHTS, OPENINGS, AND LOCATIONS INDICATED ON THE STRUCTURAL DRAWINGS ARE INDICATED FOR INFORMATIONAL PURPOSES ONLY. THE CONTRACTOR SHALL VERIFY AND COORDINATE THE SIZES, WEIGHTS, AND LOCATIONS OF ALL EQUIPMENT AND OPENINGS. REPORT ANY DISCREPANCIES TO THE ARCHITECT/ENGINEER.
6. THE REFERENCE DATUM (ELEVATION = 0'-0") FOR ELEVATIONS SHOWN ON THESE DRAWINGS SHALL BE FINISHED FLOOR ELEVATION WHICH PREDOMINATES ON THE FIRST FLOOR. REFER TO CIVIL DRAWINGS FOR ACTUAL FINISHED FLOOR
ELEVATION AND ADDITIONAL INFORMATION.
7. WHERE A SECTION OR DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL LIKE AND SIMILAR CONDITIONS.
8. UNDER NO CIRCUMSTANCES SHALL THE CONTRACT DRAWINGS BE REPRODUCED, IN PART OR IN WHOLE, AND USED AS
SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER.
9. ALL LOADS AND REACTIONS ON DRAWINGS AND IN THESE GENERAL STRUCTURAL NOTES ARE UNFACTORED SERVICE LOADS UNLESS OTHERWISE NOTED. LOAD CASES WHICH INCLUDE COMBINED LOADS SHALL BE CALCULATED IN
ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
10. THE GENERAL STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS AND SPECIFICATIONS. SHOULD CONFLICTS EXIST BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE GENERAL STRUCTURAL NOTES, THE
STRICTEST PROVISION SHALL GOVERN.
11. PRODUCTS AND MANUFACTURERS SPECIFICALLY IDENTIFIED IN THE DRAWINGS ARE REQUIRED TO COMPLY WITH THE DESIGN. BEFORE SUBMITTING SUBSTITUTIONS, CONFIRM LOAD CAPACITY BASED ON RELIABLE TESTING DATA OR CALCULATIONS PUBLISHED BY AN INDEPENDENT THIRD PARTY. THE ENGINEER OF RECORD SHALL EVALUATE AND GIVE WRITTEN APPROVAL FOR SUBSTITUTIONS PRIOR TO INSTALLATION. INSTALL ALL PRODUCTS IN ACCORDANCE WITH
MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS.
12. RECORD DOCUMENTS FOR THE EXISTING STRUCTURE ADJACENT TO NEW CONSTRUCTION WERE UNAVAILABLE. THE EXISTING CONSTRUCTION SHOWN IS BASED UPON LIMITED FIELD INVESTIGATION AND EXTRAPOLATION BASED UPON SIMILAR CONSTRUCTION SHOWN IN RECORD DOCUMENTS OF ADJACENT CONSTRUCTION. THE CONDITIONS AS THEY EXIST TODAY WILL VARY FROM THE AVAILABLE RECORD DOCUMENTS. THE CONTRACTOR MUST FIELD VERIFY ALL RELEVANT DIMENSIONS, MATERIALS AND CONSTRUCTION AS PART OF THEIR SHOP DRAWING AND SUBMITTAL PREPARATION. DEVIATIONS FROM THE INFORMATION PRESENTED IN THE CONTRACT DOCUMENTS MUST IMMEDIATELY BE
BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND ENGINEER OF RECORD.
GENERAL STRUCTURAL NOTES:
1. 2021 EDITION OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC).
A. PART 1 : VIRGINIA CONSTRUCTION CODE (VCC).
B. PART 2 : VIRGINIA EXISTING BUILDING CODE.
2. 2022 EDITION OF THE AMERICAN SOCIETY OF CIVIL ENGINEERS/STRUCTURAL ENGINEERS INSTITUTE (ASCE/SEI): ASCE/SEI
7-22, "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES".
3. 2014 EDITION OF THE AMERICAN CONCRETE INSTITUTE (ACI): ACI 318-14, "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE".
4. 2016 EDITION OF THE AMERICAN CONCRETE INSTITUTE (ACI): ACI 530-16, "BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES" AND ACI 530.1-16, "SPECIFICATIONS FOR MASONRY STRUCTURES".
DESIGN CODES AND GOVERNING STANDARDS:
THE FOLLOWING LOADS IN ADDITION TO THE DEAD LOADS OF THE PERMANENT CONSTRUCTION BUILDING MATERIALS WERE
USED:
FLOOR LIVE LOAD(S):
STORAGE AREA : 125 PSF
ALL OTHER AREAS : 100 PSF
ROOF LIVE LOAD:
MINIMUM ROOF LOAD : 20 PSF
SNOW LOAD:
GROUND SNOW LOAD, Pg : 10 PSF SNOW EXPOSURE FACTOR, Ce : 1.0 (PARTIALLY EXPOSED) SNOW LOAD IMPORTANCE FACTOR, Is : 1.0 THERMAL FACTOR, Ct : 1.0
WIND DESIGN CRITERIA:
ULTIMATE DESIGN WIND SPEED, Vult (3 SECOND GUST) : 115 MPH NOMINAL DESIGN WIND SPEED, Vasd : 90 MPH
RISK CATEGORY : II
WIND EXPOSURE : B
INTERNAL PRESSURE COEFFICIENT : +/-0.18
COMPONENTS AND CLADDING PRESSURE : 24 PSF
DESIGN LOADS:
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 301 "STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318/318R "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. CONCRETE PLACED IN HOT WEATHER SHALL BE PLACED IN ACCORDANCE WITH ACI 305 "HOT WEATHER CONCRETING." CONCRETE PLACED IN COLD WEATHER
SHALL BE PLACED IN ACCORDANCE WITH ACI 306 "COLD WEATHER CONCRETING."
2. ALL CAST-IN-PLACE CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH CEMENT TYPE II AND ATTAIN THE FOLLOWING MINIMUM 28 DAY COMPRESSIVE STRENGTHS (f'c):
A. SLAB-ON-GRADE : 4,000 PSI
B. CONCRETE NOT OTHERWISE NOTED : 3,000 PSI
3. REINFORCING MATERIALS SHALL BE AS FOLLOWS:
A. REINFORCING BARS : ASTM A 615, GRADE 60, DEFORMED
B. WELDED WIRE REINFORCEMENT : ASTM A 185 - WELDED STEEL WIRE REINFORCEMENT; PROVIDE FLAT SHEETS
ONLY, ROLL TYPE IS PROHIBITED.
4. BEND ALL BARS 24 DIAMETERS AROUND CORNERS. ALL BENT BARS SHALL BE SHOP FABRICATED. FIELD BENDING OF
REINFORCEMENT IS NOT PERMITTED.
5. PROVIDE 3/4" CHAMFERS ON ALL EXPOSED EDGES OF CONCRETE, UNLESS OTHERWISE NOTED.
6. THE SLUMP OF CAST-IN-PLACE CONCRETE SHALL NOT EXCEED 4 INCHES WITHOUT A HIGH RANGE WATER REDUCING ADMIXTURE. THE SLUMP OF CAST-IN-PLACE CONCRETE WITH THE USE OF A HIGH RANGE WATER REDUCING ADMIXTURE SHALL NOT EXCEED 8 INCHES. THE SLUMP OF CONCRETE SHALL BE DETERMINED WITH ACCORDANCE WITH ASTM C143.
ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED 5% TO 7%. ENTRAPPED AIR SHALL NOT EXCEED 3%.
7. ALL REINFORCING STEEL AND EMBEDDED ITEMS SUCH AS ANCHOR BOLTS AND WELD PLATES SHALL BE ACCURATELY PLACED AND HELD SECURELY TO PREVENT DISPLACEMENT DURING THE CONCRETE PLACEMENT. DO NOT WET SET DOWELS, ANCHOR BOLTS, OR OTHER EMBEDDED ITEMS. ALL REINFORCEMENT SHALL BE SUPPORTED ON PLASTIC- PROTECTED WIRE BAR SUPPORTS OR PRECAST CONCRETE BAR SUPPORTS OF GREATER COMPRESSIVE STRENGTH THAN THE CONCRETE, MANUFACTURED IN ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTE (CRSI)
MANUAL OF STANDARD PRACTICE.
CAST-IN-PLACE CONCRETE NOTES:
8. DURING THE PLACEMENT OF CONCRETE SLABS, TAKE ALL NECESSARY STEPS TO AVOID PLASTIC SHRINKAGE CRACKS DUE TO WEATHER. WET CURE ALL CONCRETE SLABS. CONVENTIONAL SAWED JOINTS SHALL BE COMPLETED WITHIN 4
TO 12 HOURS AFTER THE CONCRETE HAS BEEN FINISHED.
9. MINIMUM CONCRETE COVER FOR PROTECTION OF REINFORCEMENT SHALL BE AS FOLLOWS, UNLESS THE DRAWINGS
DEPICT GREATER COVER REQUIREMENTS:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH : 3 INCHES
B. CONCRETE CAST AGAINST FORMWORK : 1 1/2 INCHES
C. ALL OTHER LOCATIONS : 1 1/2 INCHES (UNLESS OTHERWISE NOTED)
10. UNLESS OTHERWISE NOTED, SPLICES IN TOP REINFORCING SHALL BE MADE AT MID-SPAN BETWEEN SUPPORTS AND
SPLICES IN BOTTOM REINFORCING SHALL BE MADE OVER SUPPORTS.
11. WHERE NEW CONCRETE IS PLACED AGAINST EXISTING, INCLUDING RECENTLY PLACED CONCRETE WHICH IS NO LONGER PLASTIC, COAT THE EXISTING CONCRETE SURFACE ABUTTING NEW WITH AN EPOXY BONDING COMPOUND.
12. FORMWORK SHALL BE IN ACCORDANCE WITH CHAPTER 26 OF ACI 318.
13. THE USE OF POST-INSTALLED REINFORCING STEEL AND ANCHOR BOLTS, EITHER WITH ADHESIVE, EPOXY GROUT AND/OR MECHANICAL SYSTEMS, WILL NOT BE PERMITTED UNLESS OTHERWISE NOTED. THE USE OF POST-INSTALLED SYSTEMS WILL BE CONSIDERED FOR REMEDIAL PURPOSES ONLY, SUBJECT TO APPROVAL BY THE ENGINEER OF RECORD.
14. MIXING AND DELIVERY OF CONCRETE SHALL COMPLY WITH ASTM C94 OR ASTM C685.
CAST-IN-PLACE CONCRETE NOTES: (CONTINUED)
1. CONCRETE MASONRY SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH (F'm) OF 2,500 PSI AND BE IN
ACCORDANCE TO THE FOLLOWING:
A. CONCRETE MASONRY UNITS - ASTM C90, LIGHTWEIGHT
B. CONCRETE FACING BRICK - ASTM C1634
C. NON-LOADBEARING CONCRETE MASONRY UNITS - ASTM C129
D. MORTAR - ASTM C270, TYPE M, S OR N MASONRY CEMENT
E. GROUT - ASTM C476, (F'G) - 3,000 PSI (MIN)
F. SELF-CONSOLIDATING GROUT (SCG) - ASTM C404
G. REINFORCING BARS - ASTM A615, GRADE 60 DEFORMED BARS
H. TYPE N MORTAR SHALL BE USED FOR MASONRY VENEER.
I. JOINT REINFORCEMENT - ASTM A653 G60
2. ALL REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A615, GRADE 60 DEFORMED BARS, UNLESS OTHERWISE
NOTED.
3. ALL MORTAR FOR USE IN MASONRY BEARING WALLS SHALL BE IN ACCORDANCE WITH ASTM C-270 TYPE "S" MORTAR. USE TYPE "M" MORTAR FOR BELOW GRADE MASONRY. GROUT ALL CELLS SOLID BELOW FINISHED FIRST FLOOR UNLESS
OTHERWISE NOTED.
4. PROVIDE FOUNDATION DOWELS FOR ALL REINFORCED MASONRY WALLS WITH STANDARD ACI HOOK. LAP 48 BAR DIAMETERS WITH VERTICAL MASONRY REINFORCING, NUMBER, SIZE AND SPACING OF DOWELS SHALL MATCH WALL
REINFORCING. DOWELS SHALL BE WIRE TIED AND NOT SET INTO WET CONCRETE.
5. ALL REINFORCING STEEL MARKED CONTINUOUS (CONT.) SHALL BE LAPPED 48 BAR DIAMETERS AT SPLICES, UNLESS
OTHERWISE NOTED. FULLY GROUT ALL REINFORCED CELLS, BOND BEAMS AND LINTELS.
6. THE MASONRY CONTRACTOR SHALL BUILD, REINFORCE AND GROUT THE WALLS IN NO GREATER THAN 5'-4" LIFTS, MECHANICALLY VIBRATING GROUT IMMEDIATELY AFTER EACH LIFT.
7. LAP ALL REINFORCING AS FOLLOWS:
#3 - 12" #6 - 53" #4 - 18" #7 - 63" #5 - 28" #8 - 72"
8. HORIZONTAL JOINTS SHALL BE REINFORCED WITH GALVANIZED STANDARD NO. 9 GAGE LADDER TYPE AT 16" ON CENTER
ON ALL WALLS, LAP MINIMUM OF 6 INCHES.
9. DIMENSIONS SHOWN FOR CMU WALLS ARE NOMINAL BLOCK. HOLD DIMENSIONS TO OUTSIDE FACE OF CMU.
10. REFER TO ARCHITECTURAL DRAWINGS FOR ANY ADDITIONAL REQUIREMENTS.
11. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT INTERVALS NOT EXCEEDING 200
BAR DIAMETERS OF THE REINFORCEMENT.
12. PROVIDE ONE VERTICAL BAR THE SAME SIZE AS WALL REINFORCING AT CORNERS AND ENDS OF WALLS. REFER TO
TYPICAL WALL REINFORCING DETAILS.
13. HOLLOW UNIT MASONRY CONSTRUCTION SHALL CURE AT LEAST 24 HOURS BEFORE GROUTING EACH LIFT.
14. ALL MASONRY BOND BEAMS AND LINTELS SHALL BE REINFORCED WITH (2)-#5 MINIMUM AND SHALL BE COMPLETELY GROUTED, UNLESS OTHERWISE NOTED. BOND BEAMS AT INTERSECTING CMU WALLS SHALL MEET AT THE SAME
ELEVATION AND THE REINFORCING SHALL BE LAPPED AS REQUIRED.
15. ALL MASONRY SHALL BE LAID IN A RUNNING BOND PATTERN, UNLESS OTHERWISE NOTED.
MASONRY NOTES:
ACI
ADDIT.
AISC
ARCH.
ASTM
AWS
BLDG.
B.O.
BOTT.
BRG.
CL
CLR.
CMU
COL.
CONC.
CONN.
CONT.
COORD.
DBL.
DEMO.
DET.
DIA.
DIAG.
DWGS.
EA.
E.F.
E.W.
ELEV.
EMBED.
EQ.
EXIST.
EXP.
F.F.
F.F.E.
FIN.
FLR.
FNDN.
FTG.
F.V.
GA.
GALV.
HORIZ.
AMERICAN CONCRETE INSTITUTE
ADDITION/ADDITIONAL
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ARCHITECTURAL
AMERICAN STANDARD FOR TESTING OF MATERIALS
AMERICAN WELDING SOCIETY
BUILDING
BOTTOM OF
BOTTOM
BEARING
CENTERLINE
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECT/CONNECTION
CONTINUE/CONTINUOUS
COORDINATE
DOUBLE
DEMOLISH/DEMOLITION
DETAIL
DIAMETER
DIAGONAL
DRAWINGS
EACH
EACH FACE
EACH WAY
ELEVATION
EMBEDDED/EMBEDMENT
EQUAL/EQUALLY
EXISTING
EXPANSION
FINISHED FLOOR
FINISHED FLOOR ELEVATION
FINISHED
FLOOR
FOUNDATION
FOOTING
FIELD VERIFY
GAGE
GALVANIZED
HORIZONTAL
ABBREVIATION LEGEND
INFO.
KSI
LBS.
LLH
LLV
LT.
L.W.
MANUF.
MAS.
MAX.
MIN.
MECH.
MTL.
o/c
OPNG.
OPP.
PEJ
PL
PROJ.
PSF
PSI
REINF.
REM.
REQD.
RTU
SB
SCHED.
SECT.
SIM.
STD.
STL.
STRUCT.
S.W.
THK.
T.O.
TYP.
U.O.N.
VERT.
W.P.
WT.
WWR
W/
INFORMATION
KIPS PER SQUARE INCH
POUNDS
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LIGHT
LONG WAY
MANUFACTURER
MASONRY
MAXIMUM
MINIMUM
MECHANICAL
METAL
ON CENTER
OPENING
OPPOSITE
PREMOLDED EXPANSION JOINT
PLATE
PROJECTION
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
REINFORCED/REINFORCING
REMAINDER
REQUIRED
ROOF TOP UNIT
SLAB BEAM
SCHEDULE
SECTION
SIMILAR
STANDARD
STEEL
STRUCTURAL
SHORT WAY
THICK
TOP OF
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
WORKING POINT
WEIGHT
WELDED WIRE REINFORCEMENT
WITH
STRUCTURAL SYMBOLS
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
WALL SECTION TAG
SECTION NUMBER
SHEET WHERE DRAWN
NEW WORK
KEYNOTE TAG
KEYNOTE NUMBER
DEMO
KEYNOTE TAG
KEYNOTE NUMBER
X
(+10.0')
(+10'-0")
ELEVATION CALLOUT
ELEVATION CALLOUT
ELEVATION TARGET
X
TYP.
2'-0"
T Y
P
2' -0
OPENINGS EXCEEDING 2'-0", BUT NOT OVER 4'-0"
IN ANY DIRECTION
FOR EITHER INTERIOR OR EXTERIOR
WALLS OR STRUCTURAL PARTITIONS
NOTES:
1. LINTEL BARS IN BOND BEAMS OVER OPENING MAY TAKE THE PLACE OF TOP BARS
SHOWN.
2. HORIZONTAL BARS BELOW OPENING TO BE IN BOND BEAM AT DOORS, OMIT BOTTOM
HORIZONTAL REINFORCING.
3. FOR EACH BAR (TYPICAL WALL REINFORCING) INTERRUPTED, ADD ONE BAR EACH
SIDE OF OPENING, MINIMUM (2)-BARS EACH SIDE.
(2)-#4, MIN. EA. SIDE.
INSIDE BAR CONT.
(2)-#4
TYP. WALL REINF.
NOTE:
PLACE "INSIDE" BAR IN ADJACENT CELLS.
TYPICAL BAR BEAM BEARING
PERPENDICULAR
VERTICAL CONTROL
JOINT
VERT. CONTROL JOINT,
REFER TO ARCH.
DWGS. FOR LOCATION
AND DETAIL
NOTE 'A'
REINF.
(2)-CELLS
NEAREST
BEAM BRG.
A. VERTICAL WALL REINFORCING BAR AS SPECIFIED. REFER TO OTHER DETAILS AND SECTIONS FOR SIZE AND
SPACING.
B. VERTICAL WALL REINFORCING BAR AS SPECIFIED (PROVIDE #4 BAR WHERE NOT OTHERWISE SPECIFIED).
C. ADDITIONAL VERTICAL WALL REINFORCING BARS MAY BE REQUIRED, REFER TO PLANS AND OTHER DETAILS.
D. CENTERLINE OF BEAM/GIRDER ABOVE, REFER TO FRAMING PLANS FOR EXACT LOCATION.
CORNER INTERSECTION OPENING BEAM BEARING AT
END OR CORNER
GROUT ALL
REINF. CELLS
SOLID, TYP.
IN
T
E
X T
OPNG.
NOTE 'D'
NOTE 'D'
NOTE 'B'
NOTE 'B',
TYP.
EQEQ
E Q
E Q
/8
WALL THICKNESS
3/8"
NOTE 'B' NOTE 'B'
OPNG.NOTE 'B'
NOTE 'C'
NOTE 'B'
NOTES:
BOND BEAM, REFER TO
SCHED. FOR REINF.
EXTERIOR WALL
1/4"x1 1/2"x24" STRAP ANCHOR
W/ 3" RIGHT ANGLE BENDS AT
EA. END AT VERT. SPACING
NOT EXCEEDING 16" O.C.
ADD VERT. REINF. AS SHOWN,
REFER TO PLAN FOR SIZE
RAKE OUT AND CAULK TO
FORM CONTROL JOINT INTERIOR WALL
EMBED BENT ENDS IN
FULLY GROUTED CELLS
INSTALL PIPE SLEEVE W/
DIA. 2" GREATER THAN PIPE
FILL VOID AROUND PIPE
W/ COMPRESSIBLE FOAM
PIPE, REFER TO
PLUMBING DWGS.
CMU WALL,
REFER TO PLAN.
DO NOT
PENETRATE AT
REINF. CELL.
M D G cPHERSON
ESIGN
ROUP
STRUCTURAL ENGINEERS
www.mdg-eng.com
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
S
U A
N C
E S
C H
E D
U
DATE ISSUED:
N U
M B
S
C R
IP
T
DRAWN BY:
CHECKED BY:
OFHTLAE
W
N O M M O
C
A I
N I
G
RI
V
MATTHEW J. LOMBARDO
Lic. No. 55182
P R O F
E S
S I ONA L EN
G I N
E E R
09-02-2025
PRELIMINARY
NOT FOR
CONSTRUCTION
F \2
-0
\D
W G
S
R e vi t2 \2
-0
W a te rs M id d le
S ch o o l.r vt
/2
/2
:3
:1
A
M
GENERAL NOTES
S-001
JAK
GMG
MJL
10012314.07
09/02/2025
W A
T E
R S
M
ID
D L
E S
C H
O O
L C
IT
Y
O F
P O
R T
S M
O U
T H
R
O O
S E
V E
L T
R D
P O
R T
S M
O U
T H
V
A
A D
A R
E S
T R
O O
M R
E N
O V
A T
IO
N
S
NOT TO SCALE
TYPICAL MASONRY OPENING REINFORCING DETAIL
NOT TO SCALE
TYPICAL WALL REINFORCING DETAILS
NOT TO SCALE
TYPICAL INTERSECTION OF BEARING AND
NON-BEARING MASONRY WALLS DETAIL
NOT TO SCALE
TYPICAL PIPE SLEEVE
THRU CMU WALL DETAIL
09/02/2025
100% BID
DOCUMENTS
S-102
S-102 D
S-102 B
S-102 C
S-103 A
S-103 B
S-103 C
S-102 F
S-102 E
NOT IN SCOPE OF WORK NOT IN SCOPE OF WORK
M D G cPHERSON
ESIGN
ROUP
STRUCTURAL ENGINEERS
www.mdg-eng.com
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
S
U A
N C
E S
C H
E D
U
DATE ISSUED:
N U
M B
S
C R
IP
T
DRAWN BY:
CHECKED BY:
OFHTLAE
W
N O M M O
C
A I
N I
G
RI
V
MATTHEW J. LOMBARDO
Lic. No. 55182
P R O F
E S
S I ONA L EN
G I N
E E R
09-02-2025
PRELIMINARY
NOT FOR
CONSTRUCTION
F \2
-0
\D
W G
S
R e vi t2 \2
-0
W a te rs M id d le
S ch o o l.r vt
/2
/2
:3
:1
A
M
OVERALL PLAN
S-101
JAK
GMG
MJL
10012314.07
09/02/2025
W A
T E
R S
M
ID
D L
E S
C H
O O
L C
IT
Y
O F
P O
R T
S M
O U
T H
R
O O
S E
V E
L T
R D
P O
R T
S M
O U
T H
V
A
A D
A R
E S
T R
O O
M R
E N
O V
A T
IO
N
S
1/16" = 1'-0"
NEW WORK OVERALL FLOOR PLAN
8' 16' 32' 64'0'
1/16" =1'-0"
GRAPHIC SCALE
NOTE:
IF THIS DRAWING IS A REDUCTION, GRAPHIC SCALE MUST BE USED.
A
B
C
D
E
F
KEY PLAN
09/02/2025
100% BID
DOCUMENTS
4S-103
S-103
6 6
S-103
Sim
7 TYP.
3 3
5 S-103
Sim
S-103
Sim
7 TYP.
7TYP.
S-103
Sim
S-103
Sim
7 TYP.
7TYP.
1. ALL ITEMS SHOWN ON THIS DRAWING ARE CONSIDERED NEW
CONSTRUCTION, UNLESS OTHERWISE NOTED AS EXISTING.
2. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO FOLLOW ALL
SAFETY CODES AND REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.
3. THE CONTRACTOR MUST VERIFY THE REQUIREMENTS OF OTHER
TRADES AS TO SLEEVES, ANCHORS, CHASES, INSERTS, HANGERS, ETC.
TO BE PLACED IN THE STRUCTURAL WORK.
4. CONTRACTOR MUST PROTECT EXISTING BUILDING ELEMENTS TO
REMAIN. ANY DAMAGE DONE MUST BE REPAIRED OR REPLACED AT
THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER.
5. THE CONTRACTOR MUST COORDINATE AND VERIFY ALL DIMENSIONS
PRIOR TO STARTING CONSTRUCTION. ANY DISCREPANCIES MUST BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER.
6. REFER TO ARCHITECTURAL DRAWINGS AND DETAILS FOR OPENINGS
AND ALL FIRE RATED CONSTRUCTION.
7. REFER TO ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS
FOR FLOOR DRAINS, SLOPES, AND PENETRATIONS.
8. TOP OF CONCRETE SLAB ELEVATION MUST BE (0'-0"), UNLESS
OTHERWISE NOTED.
9. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS TO MASONRY
WALLS.
10. REFER TO AND COORDINATE WITH PLUMBING AND CIVIL DRAWINGS
FOR PENETRATIONS THROUGH SLAB. PROVIDE SLEEVE FOR PIPES IN
THE SLAB.
PLAN NOTES:
1. EXISTING FOUNDATION WALL AND FOOTING.
2. EXISTING CONCRETE SLAB-ON-GRADE.
3. EXISTING MASONRY WALL, FIELD VERIFY.
4. CONTRACTOR MUST DEMOLISH EXISTING MASONRY WALL DENOTED
ON PLAN (-0'-8") BELOW FINISHED FLOOR ELEVATION. PROVIDE NEW
CONCRETE INFILL, 8" DEEP, MINIMUM, BY WIDTH OF WALL. REINFORCE
AS SHOWN IN SECTIONS ON SHEET S-103.
5. AFFIX NEW MASONRY WALL TO EXISTING WITH #4 DOWELS DRILLED
AND EPOXIED INTO EXISTING WALL AT 24" ON CENTER, VERTICAL.
6. NEW MASONRY WALL TYPE, COORDINATE WITH ARCHITECTURAL
DRAWINGS. REINFORCE WITH #4 AT 24" ON CENTER, GROUTED SOLID.
REFER TO WALL REINFORCING DETAILS FOR ADDITIONAL
REINFORCING. MASONRY WALL TO SIT ATOP EXISTING CONCRETE
SLAB-ON-GRADE. DRILL AND EPOXY INTO EXISTING CONCRETE SLAB A
MINIMUM OF 2 1/2". CONTRACTOR MUST CONFIRM CONCRETE SLAB-
ON-GRADE THICKNESS IS 4" MINIMUM.
7. PLUMBING FIXTURE, REFER TO PLUMBING DRAWINGS.
8. CONTRACTOR MUST "TEETH-IN" CMU INTO EXISTING WALL (CMU TO
MATH EXISTING). FILL SOLID WITH GROUT AND PROVIDE (1)-#5 BAR
FOR VERITCAL REINFORCING.
PLAN KEY NOTES: X
3 3
S-103
Sim7
7 TYP.
4 33
5 5
S-103
Sim
S-103
Sim 77
M D G cPHERSON
ESIGN
ROUP
STRUCTURAL ENGINEERS
www.mdg-eng.com
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6 7
A
B
C
D
E
F
IS
S
U A
N C
E S
C H
E D
U
DATE ISSUED:
N U
M B
S
C R
IP
T
DRAWN BY:
CHECKED BY:
OFHTLAE
W
N O M M O
C
A I
N I
G
RI
V
MATTHEW J. LOMBARDO
Lic. No. 55182
P R O F
E S
S I ONA L EN
G I N
E E R
09-02-2025
PRELIMINARY
NOT FOR
CONSTRUCTION
F \2
-0
\D
W G
S
R e vi t2 \2
-0
W a te rs M id d le
S ch o o l.r vt
/2
/2
:3
:2
A
M
ENLARGED PLANS
S-102
JAK
GMG
MJL
10012314.07
09/02/2025
W A
T E
R S
M
ID
D L
E S
C H
O O
L C
IT
Y
O F
P O
R T
S M
O U
T H
R
O O
S E
V E
L T
R D
P O
R T
S M
O U
T H
V
A
A D
A R
E S
T R
O O
M R
E N
O V
A T
IO
N
S
1/4" = 1'-0" (S-101) A
ENLARGED PLAN - ROOM 133
1/4" = 1'-0" (S-101) D
ENLARGED PLAN - ROOMS 116A/116B
1/4" = 1'-0" (S-101) B
ENLARGED PLAN - ROOM 178
1/4" = 1'-0" (S-101)
C
ENLARGED PLAN - ROOM 128
2' 4' 8' 16'0'
1/4" =1'-0"
GRAPHIC SCALE
NOTE:
IF THIS DRAWING IS A REDUCTION, GRAPHIC SCALE MUST BE USED.
1/4" = 1'-0" (S-101) E
ENLARGED PLAN - ROOMS 197/201
1/4" = 1'-0" (S-101)
F
ENLARGED PLAN - ROOMS 155A/155B A
B
C
D
E
F
KEY PLAN
09/02/2025
100% BID
DOCUMENTS
1. ALL ITEMS SHOWN ON THIS DRAWING ARE CONSIDERED NEW
CONSTRUCTION, UNLESS OTHERWISE NOTED AS EXISTING.
2. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO FOLLOW ALL
SAFETY CODES AND REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.
3. THE CONTRACTOR MUST VERIFY THE REQUIREMENTS OF OTHER
TRADES AS TO SLEEVES, ANCHORS, CHASES, INSERTS, HANGERS, ETC.
TO BE PLACED IN THE STRUCTURAL WORK.
4.…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .