2.1718_Seaholm G003 Remodel_Bids Elec_03-15-18.pdf
PDF 2 MB Posted
- Attached to
- 2. 1718_Seaholm ASD Classroom G003 Remodel
- Solicitation number
- RFP-BPS-180000002473-2
- Issued by
- Michigan
About this file
This file contains electrical specification drawings and plans for the Seaholm High School Remodeling project in Birmingham Public Schools, Birmingham, Michigan. The documents include electrical sheet indexes, symbol lists, specifications, and detailed floor plans showing both demolition and new electrical work for Zone 'A' of the first level. The plans include lighting fixture schedules detailing specific types of LED fixtures to be installed.
The electrical drawings show comprehensive demolition plans for existing lighting and power systems as well as new installation plans featuring LED lighting fixtures, power systems, and associated electrical infrastructure. The plans include detailed notes regarding installation requirements, demolition procedures, and specifications for electrical components. A key plan indicates this work is focused on Zone 'A' of the building, which appears to be a section containing classroom or institutional spaces based on the floor layout. The project number is listed as 18013, with drawing numbers E0.1, E0.1A, and E1.1A shown on the sheets.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
EG0.1
AutoCAD SHX Text
ELECTRICAL SHEET INDEX, SYMBOLS LIST AND SPECIFICATIONS
AutoCAD SHX Text
0-10 VOLT LED TYPE DIMMER SWITCH
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text
0-10 VOLT LED TYPE DIMMER SWITCH - THREE WAY
AutoCAD SHX Text S
AutoCAD SHX Text D3
AutoCAD SHX Text
SINGLE GANG CAST BOX FOR VOICE / DATA
AutoCAD SHX Text
DOUBLE DUPLEX RECEPTACLE
AutoCAD SHX Text
DUPLEX RECEPTACLE
AutoCAD SHX Text
EXIT LIGHT, (SHADED AREA INDICATED FACE OF FIXTURE), TYPE AS INDICATED
AutoCAD SHX Text
THREE WAY SWITCH
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL SYMBOL LIST
AutoCAD SHX Text F
AutoCAD SHX Text
FIRE ALARM PULL STATION
AutoCAD SHX Text
FIRE ALARM AUDIO VISUAL DEVICE, 80" AFF, 15 CANDELA UNLESS OTHERWISE NOTED
AutoCAD SHX Text
FIRE ALARM VISUAL DEVICE, 80" AFF, 15 CANDELA UNLESS OTHERWISE NOTED
AutoCAD SHX Text
EXISTING PANELBOARD
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
GROUND FAULT INTERRUPTER
AutoCAD SHX Text
WP
AutoCAD SHX Text
WEATHERPROOF
AutoCAD SHX Text
SINGLE POLE SWITCH
AutoCAD SHX Text S
AutoCAD SHX Text 2'x4' LAY-IN LIGHT FIXTURE, TYPE AS INDICATED
AutoCAD SHX Text
CEILING MOUNTED OCCUPANCY SENSOR
AutoCAD SHX Text
CD
AutoCAD SHX Text
CANDELA
AutoCAD SHX Text
EMERGENCY LIGHT FIXTURE
AutoCAD SHX Text
CLOCK
AutoCAD SHX Text
LP
AutoCAD SHX Text
LIGHTING PANEL
AutoCAD SHX Text
RP
AutoCAD SHX Text
RECEPTACLE PANEL
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
ELECTRICAL SHEET INDEX, SYMBOL LIST AND SPECIFICATIONS
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
EG0.1
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ELECTRICAL SHEET INDEX
AutoCAD SHX Text E1.1A
AutoCAD SHX Text
FIRST LEVEL ELECTRICAL NEW WORK FLOOR PLAN - ZONE 'A'
AutoCAD SHX Text E0.1A
AutoCAD SHX Text
FIRST LEVEL ELECTRICAL DEMOLITION FLOOR PLAN - ZONE 'A'
AutoCAD SHX Text
EM
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text
INTERCOM WITH CAMERA
AutoCAD SHX Text
EXISTING LIGHT FIXTURE
AutoCAD SHX Text
EXISTING EMERGENCY LIGHT FIXTURE
AutoCAD SHX Text
EM
AutoCAD SHX Text
WALL MOUNTED SPEAKER
AutoCAD SHX Text CEILING MOUNTED FIRE ALARM AUDIO VISUAL DEVICE, 15 CANDELA UNLESS OTHERWISE NOTED
AutoCAD SHX Text
CEILING MOUNTED FIRE ALARM VISUAL DEVICE, 15 CANDELA UNLESS OTHERWISE NOTED
AutoCAD SHX Text BAI No.
AutoCAD SHX Text 36400 West Twelve Mile Road
AutoCAD SHX Text Farmington Hills, Michigan 48331
AutoCAD SHX Text
(248) 489-3100 FAX (248) 489-3161
AutoCAD SHX Text
BERBIGLIA ASSOCIATES INC.
AutoCAD SHX Text
CONSULTING ENGINEERS
AutoCAD SHX Text 18-1601
AutoCAD SHX Text
REGISTRATION SEAL
AutoCAD SHX Text
ISSUE DATES
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text A R C H I T E C T U R E
AutoCAD SHX Text T M P A R C H I T E C T U R E I N C
AutoCAD SHX Text
1191 WEST SQUARE LAKE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
EM INFO TMP-ARCHITECTURE.COM
AutoCAD SHX Text
PH 248.338.4561 FX 248.338.0223
AutoCAD SHX Text
BLOOMFIELD HILLS MICHIGAN 48302
AutoCAD SHX Text 03.15.18
AutoCAD SHX Text
BIDS
AutoCAD SHX Text
CC/VK
AutoCAD SHX Text
JB
AutoCAD SHX Text
JB
AutoCAD SHX Text 18013
AutoCAD SHX Text Seaholm
AutoCAD SHX Text High Schoool
AutoCAD SHX Text Birmingham, Michigan
AutoCAD SHX Text Remodeling
AutoCAD SHX Text Birmingham Public Schools
AutoCAD SHX Text S
ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS GENERAL 1. INCLUDE ALL ITEMS, ARTICLES, MATERIALS, LABOR, OPERATIONS OR METHODS LISTED, INCLUDE ALL ITEMS, ARTICLES, MATERIALS, LABOR, OPERATIONS OR METHODS LISTED, MENTIONED OR SCHEDULED ON DRAWINGS AND/OR HEREIN SPECIFIED OR REQUIRED, INCLUDING ALL EQUIPMENT AND INCIDENTALS NECESSARY AND REQUIRED FOR THE COMPLETE AND OPERATING SYSTEMS. 2. OBTAIN AND PAY FOR ALL PERMITS, LICENSES, INSPECTIONS, APPROVALS AND FEES OBTAIN AND PAY FOR ALL PERMITS, LICENSES, INSPECTIONS, APPROVALS AND FEES REQUIRED AND INSURE THAT THE ENTIRE ELECTRICAL INSTALLATION CONFORMS TO CODES AND REGULATIONS REQUIRED BY AUTHORITY OR AGENCY HAVING JURISDICTION OVER THE INSTALLATION, ALTERATION OR CONSTRUCTION OF WORK INCLUDED. ALL FEES SHALL BE INCLUDED IN THE BASE PROPOSAL. 3. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (N.E.C.), N.F.P.A., ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (N.E.C.), N.F.P.A., LOCAL AND STATE CODES AND ORDINANCES. 4. THE CONTRACTOR SHALL VISIT THE SITE, EXAMINE AND VERIFY THE CONDITIONS UNDER THE CONTRACTOR SHALL VISIT THE SITE, EXAMINE AND VERIFY THE CONDITIONS UNDER WHICH HIS WORK MUST BE CONDUCTED BEFORE SUBMITTING A PROPOSAL. THE SUBMITTING OF A PROPOSAL IMPLIES THAT THE CONTRACTOR HAS VISITED THE SITE AND IS CONVERSANT WITH ALL EXISTING CONDITIONS, OBSTRUCTIONS AND ALL CONDITIONS WHICH WILL BE ENCOUNTERED, AS REQUIRED TO PERFORM THE WORK AS INDICATED ON PLAN OR HEREIN SPECIFIED. 5. ELECTRICAL CONTRACTOR SHALL FURNISH ALL EQUIPMENT UNLESS OTHERWISE INDICATED ELECTRICAL CONTRACTOR SHALL FURNISH ALL EQUIPMENT UNLESS OTHERWISE INDICATED AND PERFORM ALL ELECTRICAL WORK AS REQUIRED TO COMPLETE NEW WORK AND REVISIONS INDICATED ON PLAN OR AS REQUIRED FOR THE SUCCESSFUL OPERATION OF ELECTRICAL SYSTEMS. 6. THE ELECTRICAL WORK AND REVISIONS TO THE EXISTING SYSTEMS SHALL BE AS INDICATED THE ELECTRICAL WORK AND REVISIONS TO THE EXISTING SYSTEMS SHALL BE AS INDICATED ON PLANS, BUT SHALL NOT BE LIMITED TO THE SAME, AS THE WORK SHALL BE COMPLETED IN ALL DETAILS AND REQUIREMENTS AND READY FOR THE PROPER OPERATION. 7. EXCEPT AS OTHERWISE INDICATED ON PLAN OR HEREIN SPECIFIED, ALL MATERIALS USED EXCEPT AS OTHERWISE INDICATED ON PLAN OR HEREIN SPECIFIED, ALL MATERIALS USED SHALL BE NEW AND BEAR THE U.L. LABEL WHERE SUCH SERVICE AND LABEL ARE REGULARLY PROVIDED AND BE OF THE APPROPRIATE NEMA STANDARD. REUSE EXISTING EQUIPMENT ONLY WHERE SPECIFICALLY INDICATED ON PLAN. 8. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TESTS AND INSPECTIONS NECESSARY TO ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TESTS AND INSPECTIONS NECESSARY TO DETERMINE THAT ALL WIRING AND EQUIPMENT INSTALLED UNDER THIS SPECIFICATION IS IN SATISFACTORY CONDITION AND SHALL BE PERFORMED TO THE SATISFACTION OF THE ELECTRICAL INSPECTOR OF THE LOCAL AUTHORITY AND TO ALL OTHERS HAVING JURISDICTION OVER THE ELECTRICAL WORK. 9. THE ELECTRICAL CONTRACTOR SHALL DELIVER THE CERTIFICATES OF INSPECTION AND THE ELECTRICAL CONTRACTOR SHALL DELIVER THE CERTIFICATES OF INSPECTION AND FINAL APPROVAL TO THE ARCHITECT AS A REQUIREMENT FOR FINAL PAYMENT. 10. THE ELECTRICAL CONTRACTOR SHALL GUARANTEE IN WRITING ALL WORK IN CONNECTION THE ELECTRICAL CONTRACTOR SHALL GUARANTEE IN WRITING ALL WORK IN CONNECTION WITH HIS ELECTRICAL CONTRACT FOR A PERIOD OF ONE YEAR FROM THE DATE OF COMPLETION AND ACCEPTANCE BY THE OWNER. ALL WORK AND MATERIALS REQUIRED BY THE ELECTRICAL CONTRACTOR IN ORDER TO SATISFY THE GUARANTEE SHALL BE AT NO ADDITIONAL COST TO THE OWNER. 11. PROVIDE EQUIPMENT SHOP DRAWINGS IN A PDF FORMAT FOR ELECTRICAL EQUIPMENT AS PROVIDE EQUIPMENT SHOP DRAWINGS IN A PDF FORMAT FOR ELECTRICAL EQUIPMENT AS LISTED: A. LIGHT FIXTURES LIGHT FIXTURES 12. ON COMPLETION OF WORK AND BEFORE FINAL PAYMENT IS MADE, THIS CONTRACTOR SHALL ON COMPLETION OF WORK AND BEFORE FINAL PAYMENT IS MADE, THIS CONTRACTOR SHALL PREPARE "AS-BUILT DRAWINGS". CLEARLY INDICATE ON A SET OF CONTRACT DRAWINGS ALL THE CHANGES MADE DURING CONSTRUCTION, DUE TO FIELD CONDITIONS, ADDENDA, BULLETINS, ETC. DRAWINGS SHALL INDICATE THE INSTALLED LOCATION OF ALL EQUIPMENT, OUTLETS, ETC. BASIC MATERIALS AND METHODS 1. 1. ALL DEMOLISHED ITEMS SHALL BECOME THE PROPERTY OF THIS CONTRACTOR AND HE 1. ALL DEMOLISHED ITEMS SHALL BECOME THE PROPERTY OF THIS CONTRACTOR AND HE ALL DEMOLISHED ITEMS SHALL BECOME THE PROPERTY OF THIS CONTRACTOR AND HE SHALL REMOVE SAME FROM THE PREMISES. 2. MATERIALS SALVAGED FROM THIS WORK SHALL NOT BE REUSED EXCEPT WHERE REUSE IS MATERIALS SALVAGED FROM THIS WORK SHALL NOT BE REUSED EXCEPT WHERE REUSE IS SPECIFICALLY INDICATED ON PLAN. 3. ALL WIRING NOT REQUIRED TO REMAIN SHALL BE REMOVED. UNUSED WIRING SHALL NOT BE ALL WIRING NOT REQUIRED TO REMAIN SHALL BE REMOVED. UNUSED WIRING SHALL NOT BE ABANDONED. 4. THE ORIGINAL FUNCTION OF THE PRESENT ELECTRICAL WORK TO BE MODIFIED SHALL NOT THE ORIGINAL FUNCTION OF THE PRESENT ELECTRICAL WORK TO BE MODIFIED SHALL NOT BE CHANGED UNLESS REQUIRED BY THE SPECIFIC REVISIONS TO THE SYSTEM AS SPECIFIED OR SHOWN ON THE PLANS. 5. ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF ELECTRICAL ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF ELECTRICAL SYSTEMS SHALL BE BY THE ELECTRICAL CONTRACTOR. 6. BRANCH CIRCUIT WIRE AND CABLE SHALL BE COPPER WITH 98% CONDUCTIVITY AND SHALL BRANCH CIRCUIT WIRE AND CABLE SHALL BE COPPER WITH 98% CONDUCTIVITY AND SHALL MEET THE TESTS AND STANDARDS SET FORTH BY NEMA, U.L. AND IPCEA. WIRE FOR GENERAL INDOOR USE SHALL BE COPPER, TYPE THHN/THWN, 90 DEGREES C. ALUMINUM WIRE SHALL NOT BE USED. 7. ALL POWER WIRING 120 VOLTS AND GREATER SHALL BE INSTALLED IN CONDUIT. CONDUIT ALL POWER WIRING 120 VOLTS AND GREATER SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE ELECTRIC METALLIC TUBING WITH SET SCREW FITTINGS. 8. ALL CONDUIT IN FINISHED AREAS SHALL BE INSTALLED CONCEALED AND ALL COSTS FOR ALL CONDUIT IN FINISHED AREAS SHALL BE INSTALLED CONCEALED AND ALL COSTS FOR SAME SHALL BE INCLUDED IN THIS CONTRACTORS BID. THE INSTALLATION OF SURFACE MOUNTED CONDUIT, BOXES, ETC. IN FINISHED AREAS IS NOT PERMITTED. SURFACE CONDUIT, BOXES, ETC. WILL BE PERMITTED IN UNFINISHED AREAS ONLY, EXCEPT AS OTHERWISE SPECIFICALLY APPROVED BY THE ARCHITECT. 9. STEEL CONDUIT ELBOWS AND COUPLINGS SHALL BE HOT DIPPED GALVANIZED AND CONFORM STEEL CONDUIT ELBOWS AND COUPLINGS SHALL BE HOT DIPPED GALVANIZED AND CONFORM TO THE LATEST ANSI SPECIFICATIONS FOR STEEL CONDUIT, ZINC COATED. 10. CONDUITS SHALL NOT BE SUPPORTED FROM MECHANICAL DUCTS, PIPE, OR PIPE AND DUCT CONDUITS SHALL NOT BE SUPPORTED FROM MECHANICAL DUCTS, PIPE, OR PIPE AND DUCT SUPPORTS, UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. 11. CONDUITS SHALL BE INSTALLED IN NEAT SYMMETRICAL LINES PARALLEL WITH THE BUILDING CONDUITS SHALL BE INSTALLED IN NEAT SYMMETRICAL LINES PARALLEL WITH THE BUILDING CONSTRUCTION AND ADJACENT TO BEAMS, WALLS, ETC. AND NOT ACROSS OPEN BAYS. 12. ELECTRIC SYSTEM GROUNDING SHALL IN ALL INSTANCES COMPLY WITH THE MINIMUM ELECTRIC SYSTEM GROUNDING SHALL IN ALL INSTANCES COMPLY WITH THE MINIMUM REQUIREMENTS OF THE N.E.C. METAL ENCLOSURES SHALL BE BONDED TOGETHER AND GROUNDED TO THE BUILDING GROUND SYSTEM. ALL CONDUITS SERVING WIRING OF 120 VOLTS OR GREATER SHALL INCLUDE A GROUND WIRE. 13. BRANCH CIRCUIT WIRING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 310 AND BRANCH CIRCUIT WIRING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 310 AND TABLE 310.15 ADJUSTMENT FACTORS FOR MORE THAN 3 CURRENT CARRYING CONDUCTORS IN A RACEWAY. INSTALL A MAXIMUM OF THREE CIRCUITS IN A SINGLE CONDUIT. DE-RATE THE AMPACITY PER THE NEC WHERE THE NUMBER OF CONDUCTORS EXCEEDS 3. 14. PROVIDE ACCURATE TYPED DIRECTORIES IN ALL PANELBOARDS. TRACE EXISTING CIRCUITS PROVIDE ACCURATE TYPED DIRECTORIES IN ALL PANELBOARDS. TRACE EXISTING CIRCUITS AS REQUIRED TO DETERMINE LOADS SERVED FROM EXISTING CIRCUIT BREAKERS AND COMPLETE PANELBOARD DIRECTORIES ACCORDINGLY. 15. CIRCUIT NUMBERS INDICATED ON PLAN SERVED FROM EXISTING PANELS MAY NOT CIRCUIT NUMBERS INDICATED ON PLAN SERVED FROM EXISTING PANELS MAY NOT REPRESENT THE ACTUAL CIRCUIT BREAKER POLE POSITION BUT ARE SHOWN TO INDICATE LOADS TO BE GROUPED ON THE SAME CIRCUIT. 16. LIGHT FIXTURES AND FLUORESCENT LAMPS SHALL BE AS NOTED ON PLAN AND IN THE LIGHT FIXTURES AND FLUORESCENT LAMPS SHALL BE AS NOTED ON PLAN AND IN THE LIGHTING FIXTURE SCHEDULE. LIFE SAFETY SYSTEMS 1. FIRE ALARM SYSTEM DEVICES ARE EXISTING TO REMAIN. MAINTAIN OPERATION OF SAME. FIRE ALARM SYSTEM DEVICES ARE EXISTING TO REMAIN. MAINTAIN OPERATION OF SAME. 2. EMERGENCY LIGHTING UNITAS ARE EXISTING TO REMAIN. MAINTAIN OPERATION OF SAME.EMERGENCY LIGHTING UNITAS ARE EXISTING TO REMAIN. MAINTAIN OPERATION OF SAME.
1/4"
D.7
AutoCAD SHX Text E'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
UNIFORM
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text A115
AutoCAD SHX Text
EX.
AutoCAD SHX Text
JANITOR'S
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text A110
AutoCAD SHX Text
EX.
AutoCAD SHX Text
MUSIC
AutoCAD SHX Text
LIBRARY
AutoCAD SHX Text A113
AutoCAD SHX Text
EX.
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
PLANNING
AutoCAD SHX Text A106
AutoCAD SHX Text
EX.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text A107
AutoCAD SHX Text
EX.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text A109
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text A108
AutoCAD SHX Text
EX.
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text A102
AutoCAD SHX Text
EX.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text A111
AutoCAD SHX Text
EX.
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text A105
AutoCAD SHX Text
EX.
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text A104
AutoCAD SHX Text
EX.
AutoCAD SHX Text
STAIR
AutoCAD SHX Text A103
AutoCAD SHX Text
SPECIAL EDUCATION
AutoCAD SHX Text A101
AutoCAD SHX Text G003
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A100
AutoCAD SHX Text
EX.
AutoCAD SHX Text I.D.F
AutoCAD SHX Text A112
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A100
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text 3a
AutoCAD SHX Text 3b
AutoCAD SHX Text
AutoCAD SHX Text 3a
AutoCAD SHX Text 3b
AutoCAD SHX Text E0.1A
AutoCAD SHX Text
FIRST LEVEL ELECTRICAL DEMOLITION FLOOR PLAN ZONE 'A'
AutoCAD SHX Text N
AutoCAD SHX Text
%%UFIRST LEVEL ELECTRICAL DEMOLITION FLOOR PLAN ZONE 'A'
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text BAI No.
AutoCAD SHX Text 36400 West Twelve Mile Road
AutoCAD SHX Text Farmington Hills, Michigan 48331
AutoCAD SHX Text
(248) 489-3100 FAX (248) 489-3161
AutoCAD SHX Text
BERBIGLIA ASSOCIATES INC.
AutoCAD SHX Text
CONSULTING ENGINEERS
AutoCAD SHX Text 18-1601
AutoCAD SHX Text
REGISTRATION SEAL
AutoCAD SHX Text
ISSUE DATES
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text A R C H I T E C T U R E
AutoCAD SHX Text T M P A R C H I T E C T U R E I N C
AutoCAD SHX Text
1191 WEST SQUARE LAKE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
EM INFO TMP-ARCHITECTURE.COM
AutoCAD SHX Text
PH 248.338.4561 FX 248.338.0223
AutoCAD SHX Text
BLOOMFIELD HILLS MICHIGAN 48302
AutoCAD SHX Text 03.15.18
AutoCAD SHX Text
BIDS
AutoCAD SHX Text
CC/VK
AutoCAD SHX Text
JB
AutoCAD SHX Text
JB
AutoCAD SHX Text 18013
AutoCAD SHX Text Seaholm
AutoCAD SHX Text High Schoool
AutoCAD SHX Text Birmingham, Michigan
AutoCAD SHX Text Remodeling
AutoCAD SHX Text Birmingham Public Schools
AutoCAD SHX Text
%%UDEMOLITION GENERAL NOTES:
AutoCAD SHX Text 1 REFER TO SPECIFICATIONS FOR COMPLETE REQUIREMENTS. REFER TO SPECIFICATIONS FOR COMPLETE REQUIREMENTS. 2 ELECTRICAL CONTRACTOR SHALL VISIT SITE AND VERIFY ALL EXISTING ELECTRICAL CONTRACTOR SHALL VISIT SITE AND VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING BID. INCLUDE ALL DEMOLITION WORK REQUIRED AND MAKE THE SPACE READY FOR THE INSTALLATION OF NEW SYSTEMS AND EQUIPMENT. 3 ALL ELECTRICAL DEVICES, LIGHTING, MECHANICAL EQUIPMENT SERVICES, ALL ELECTRICAL DEVICES, LIGHTING, MECHANICAL EQUIPMENT SERVICES, ETC. DOWNSTREAM OF DEVICES INTENDED TO BE DEMOLISHED OR REVISED SHALL REMAIN OPERATIONAL. PROVIDE ALL BRANCH CIRCUIT WIRING REVISIONS AS REQUIRED TO MAINTAIN OPERATION OF ALL DEVICES, LIGHTING, EQUIPMENT, ETC. NOT INTENDED TO BE REVISED. FIELD VERIFY EXISTING CONDITIONS AND INCLUDE ALL COSTS IN BID. 4 ALL EXISTING LIGHTING FIXTURES, DEVICES, CONDUIT, WIRING, BOXES, ALL EXISTING LIGHTING FIXTURES, DEVICES, CONDUIT, WIRING, BOXES, ETC. SHOWN THIS PLAN SHALL BE DEMOLISHED UNLESS OTHERWISE INDICATED TO REMAIN. 5 ELECTRICAL EQUIPMENT, DEVICES, BOXES, ETC. INDICATED ON ELECTRICAL EQUIPMENT, DEVICES, BOXES, ETC. INDICATED ON ELECTRICAL DEMOLITION DRAWINGS ARE NOT INTENDED TO SHOW COMPLETE DEMOLITION REQUIREMENTS OR ALL ITEMS TO BE DEMOLISHED BUT IS INTENDED TO SHOW MAJOR COMPONENTS ONLY. THE ELECTRICAL DEMOLITION WORK SHALL BE COMPLETE IN ALL DETAILS AND REQUIREMENTS AND READY FOR THE INSTALLATION OF NEW SYSTEMS AND EQUIPMENT. 6 REFER TO ARCHITECTURAL DRAWINGS FOR THE SCOPE OF CEILING REFER TO ARCHITECTURAL DRAWINGS FOR THE SCOPE OF CEILING SYSTEM REVISIONS INCLUDING CEILINGS BEING REMOVED OR RAISED. INCLUDE ALL ELECTRICAL WORK REQUIRED TO ACCOMMODATE CEILING SYSTEM REVISIONS INCLUDING RE-SUPPORTING OR RELOCATING CONDUIT, BOXES, WIRING, ETC. REQUIRED TO REMAIN. NOTE EXISTING ELECTRICAL CONDUIT, BOXES, RACEWAYS, ETC. MAYBE SUPPORTED FROM CEILING SYSTEM SUPPORTS THAT WILL BE REMOVED BY ARCHITECTURAL TRADES. INCLUDE ALL CONDUIT, BOX AND WIRING REVISIONS INCLUDING SUPPORTS AS REQUIRED. 7 REFER TO MECHANICAL HVAC AND PLUMBING DRAWINGS FOR REFER TO MECHANICAL HVAC AND PLUMBING DRAWINGS FOR MECHANICAL EQUIPMENT BEING DEMOLISHED. INCLUDE THE DEMOLITION OF ELECTRIC SERVICE SERVING EQUIPMENT BEING DEMOLISHED. COORDINATE ALL WORK WITH MECHANICAL TRADES AND INCLUDE ALL COSTS IN THE ELECTRICAL BID. 8 ALL EXISTING ITEMS INDICATED IN THE CONTRACT DRAWINGS HAVE BEEN ALL EXISTING ITEMS INDICATED IN THE CONTRACT DRAWINGS HAVE BEEN TAKEN FROM THE OWNERS LIMITED RECORD DRAWINGS AND CERTAIN FIELD OBSERVATIONS. THIS CONTRACTOR SHALL VISIT THE SITE AND COMPLETELY UNDERSTAND THE CONDITIONS UNDER WHICH THE WORK MUST BE PERFORMED. IF A DEPARTURE FROM THE DESIGN INTENT OF THE DOCUMENTS IS REQUIRED DUE TO THE ACTUAL FIELD CONDITIONS OBSERVED BY THE CONTRACTOR, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING FOR RESOLUTION PRIOR TO SUBMITTING FINAL BID OR ENTERING INTO A CONTRACT FOR CONSTRUCTION. FAILURE TO PROVIDE THE ARCHITECT WITH NOTIFICATION SHALL RESULT IN THE CONTRACTOR BEING HELD RESPONSIBLE TO COMPLETE ALL WORK TO MEET THE DESIGN INTENT WITH NO ADDITIONAL COST BEING INCURRED BY THE OWNER. 9 WHEN REMOVING AN ENCLOSURE, DEVICE, LIGHT FIXTURE, ETC. WIRING, WHEN REMOVING AN ENCLOSURE, DEVICE, LIGHT FIXTURE, ETC. WIRING, CONDUIT, RACEWAY, ETC. SHALL BE REMOVED COMPLETE. INCLUDE FIELD INVESTIGATIONS AND WIRE TRACING IN ORDER TO DETERMINE THE USE AND FUNCTION OF ALL EXISTING WIRING. 10 REMOVED EQUIPMENT, CONDUIT, WIRE, RECEPTACLES, TOGGLE SWITCHES, REMOVED EQUIPMENT, CONDUIT, WIRE, RECEPTACLES, TOGGLE SWITCHES, LIGHTING FIXTURES, ETC., SHALL NOT BE REUSED UNLESS OTHERWISE NOTED, SHALL BECOME THE PROPERTY OF THIS CONTRACTOR AND HE/SHE SHALL REMOVE SAME FROM THE PREMISES. REMOVED EQUIPMENT AND MATERIALS SHALL BE PROPERLY DISPOSED OF IN ACCORDANCE WITH ALL ENVIRONMENTAL REQUIREMENTS. 11 ALL WALL PENETRATIONS, CONDUITS OR CONDUIT SLEEVES NO LONGER ALL WALL PENETRATIONS, CONDUITS OR CONDUIT SLEEVES NO LONGER REQUIRED, REGARDLESS OF THE SYSTEM SERVED, SHALL BE REMOVED COMPLETE WITH THE PENETRATION PATCHED TO MAINTAIN THE ORIGINAL FIRE RATING OR CONSTRUCTION OF THE WALL.
AutoCAD SHX Text
%%UDEMOLITION KEY NOTES:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYP. OF 5
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text WHEN USING THIS DRAWING - PLOT OR PRINT FULL SIZE TO ENSURE CORRECT SCALE. NOTE REDUCED SIZE DRAWINGS ARE NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text Key Plan
AutoCAD SHX Text N
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text E
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
EXISTING ELP-M1A 277/480V, 3 , 4W
AutoCAD SHX Text
EXISTING LCP-M1A 277/480V, 3 , 4W
AutoCAD SHX Text
EXISTING LP-M1A 277/480V, 3 , 4W
AutoCAD SHX Text
EXISTING RP-M12 120/208V, 3 , 4W
AutoCAD SHX Text
EXISTING RP-M11 120/208V, 3 , 4W
AutoCAD SHX Text
EXISTING RPIT-M11 120/208V, 3 , 4W
AutoCAD SHX Text
EXISTING ERP-M11 120/208V, 3 , 4W
EXISTING PENDANT LINEAR FLUORESCENT LIGHTING FIXTURES TO BE REMOVED. EXISTING LIGHTING SWITCHES TO REMAIN AND TO BE REUSED. SEE NEW WORK PLAN DRAWING E1.1A. EXISTING LIGHTING TRACK AND TRACK LIGHT FIXTURES TO BE RELOCATED. EXISTING SPEAKER TO BE RELOCATED. EXISTING VIDEO MONITOR TO BE REMOVED. REMOVE ALL ASSOCIATED WIRING AND CONTROLS. EXISTING PENDANT FLUORESCENT DOWNLIGHT FIXTURES TO BE REMOVED. EXISTING HOOD LIGHT TO BE REMOVED. REMOVE ALL ASSOCIATED WIRING AND SWITCH ENTIRELY.
¾
1/4"
AutoCAD SHX Text D.7
AutoCAD SHX Text E'
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text 3a
AutoCAD SHX Text 3b
AutoCAD SHX Text
AutoCAD SHX Text 3a
AutoCAD SHX Text 3b
AutoCAD SHX Text D.7
AutoCAD SHX Text E'
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E1.1A
AutoCAD SHX Text
FIRST LEVEL ELECTRICAL NEW WORK FLOOR PLAN ZONE 'A'
AutoCAD SHX Text N
AutoCAD SHX Text
%%UFIRST LEVEL NEW LIGHTING FLOOR PLAN ZONE 'A'
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text BAI No.
AutoCAD SHX Text 36400 West Twelve Mile Road
AutoCAD SHX Text Farmington Hills, Michigan 48331
AutoCAD SHX Text
(248) 489-3100 FAX (248) 489-3161
AutoCAD SHX Text
BERBIGLIA ASSOCIATES INC.
AutoCAD SHX Text
CONSULTING ENGINEERS
AutoCAD SHX Text 18-1601
AutoCAD SHX Text
REGISTRATION SEAL
AutoCAD SHX Text
ISSUE DATES
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text A R C H I T E C T U R E
AutoCAD SHX Text T M P A R C H I T E C T U R E I N C
AutoCAD SHX Text
1191 WEST SQUARE LAKE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
EM INFO TMP-ARCHITECTURE.COM
AutoCAD SHX Text
PH 248.338.4561 FX 248.338.0223
AutoCAD SHX Text
BLOOMFIELD HILLS MICHIGAN 48302
AutoCAD SHX Text 03.15.18
AutoCAD SHX Text
BIDS
AutoCAD SHX Text
CC/VK
AutoCAD SHX Text
JB
AutoCAD SHX Text
JB
AutoCAD SHX Text 18013
AutoCAD SHX Text Seaholm
AutoCAD SHX Text High Schoool
AutoCAD SHX Text Birmingham, Michigan
AutoCAD SHX Text Remodeling
AutoCAD SHX Text Birmingham Public Schools
AutoCAD SHX Text
%%UNEW WORK GENERAL NOTES:
AutoCAD SHX Text
%%UNEW WORK KEY NOTES:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 REFER TO SPECIFICATIONS FOR COMPLETE REQUIREMENTS. REFER TO SPECIFICATIONS FOR COMPLETE REQUIREMENTS. 2 REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. 3 ALL NEW LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING ALL NEW LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE AND IN ACCORDANCE WITH NEC AND LOCAL REQUIREMENTS. 4 ALL LIGHTING TO REMAIN, SERVED ON A CIRCUIT DOWNSTREAM OF ALL LIGHTING TO REMAIN, SERVED ON A CIRCUIT DOWNSTREAM OF LIGHTING OR DEVICES BEING DEMOLISHED OR REVISED SHALL REMAIN OPERATIONAL. PROVIDE ALL BRANCH CIRCUIT WIRING REVISIONS AS REQUIRED TO MAINTAIN OPERATION OF LIGHTING, NOT INTENDED TO BE REVISED. 5 REFER TO ARCHITECTURAL DRAWINGS FOR THE SCOPE OF CEILING REFER TO ARCHITECTURAL DRAWINGS FOR THE SCOPE OF CEILING SYSTEM REVISIONS. INCLUDE ALL ELECTRICAL WORK REQUIRED TO ACCOMMODATE CEILING SYSTEM REVISIONS INCLUDING RE-SUPPORTING OR RELOCATING CONDUIT, BOXES, WIRING, ETC. REQUIRED TO REMAIN. INCLUDE ALL CONDUIT, BOX AND WIRING REVISIONS REQUIRED. 6 ALL CONDUIT AND WIRING SHALL BE CONCEALED IN ALL FINISHED AREAS. ALL CONDUIT AND WIRING SHALL BE CONCEALED IN ALL FINISHED AREAS. 7 ALL JUNCTION BOXES SERVING BRANCH CIRCUIT WIRING SHALL BE ALL JUNCTION BOXES SERVING BRANCH CIRCUIT WIRING SHALL BE LABELED WITH CIRCUITS BEING SERVED. USE INDELIBLE MARKER ON BOX COVER. 8 ALL 120 VOLT BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL ALL 120 VOLT BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR. 9 ALL CONDUIT SERVING WIRING 120 VOLTS OR GREATER SHALL HAVE A ALL CONDUIT SERVING WIRING 120 VOLTS OR GREATER SHALL HAVE A GROUND WIRE. 10 ALL 120 VOLT BRANCH CIRCUITS SHALL BE 2#12 + 1#12 GROUND - ¾” C ALL 120 VOLT BRANCH CIRCUITS SHALL BE 2#12 + 1#12 GROUND - ¾” C ” C SERVED FROM A 20 AMP SINGLE POLE CIRCUIT BREAKER UNLESS OTHERWISE REQUIRED. 11 BRANCH CIRCUIT WIRING SHALL BE IN STRICT ACCORDANCE WITH NEC BRANCH CIRCUIT WIRING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 310 AND TABLE 310.15 ADJUSTMENT FACTORS FOR MORE THAN 3 CURRENT CARRYING CONDUCTORS IN A RACEWAY. INSTALL A MAXIMUM OF THREE CIRCUITS IN A SINGLE CONDUIT. DE-RATE THE AMPACITY PER THE NEC WHERE THE NUMBER OF CONDUCTORS EXCEEDS 3. 12 CIRCUIT NUMBERS INDICATED ON PLAN SERVED FROM EXISTING PANELS CIRCUIT NUMBERS INDICATED ON PLAN SERVED FROM EXISTING PANELS MAY NOT REPRESENT THE ACTUAL CIRCUIT BREAKER POLE POSITION BUT ARE SHOWN TO INDICATE LOADS TO BE GROUPED ON THE SAME CIRCUIT. 13 PROVIDE UPDATED TYPED DIRECTORIES IN ALL PANELBOARDS TO REFLECT PROVIDE UPDATED TYPED DIRECTORIES IN ALL PANELBOARDS TO REFLECT PROJECT CIRCUITING REVISIONS. 14 PROVIDE AS-BUILT DRAWINGS INDICATING FINAL REVISIONS.PROVIDE AS-BUILT DRAWINGS INDICATING FINAL REVISIONS.
AutoCAD SHX Text RELOCATED SPEAKERS. LOCATE TOP 12" BELOW NEW CEILING. RECONNECT TO EXISTING SOUND SYSTEM TO MAINTAIN OPERATION. RELOCATED TRACK LIGHTING. RECONNECT TO EXISTING DIMMER SWITCH AND EXISTING CIRCUIT RP-M12-17. SEE DRAWING E0.1A FOR PANEL LOCATION. FIELD VERIFY EXACT CIRCUIT NUMBER. EXISTING LIGHTING SWITCHES TO REMAIN. NEW RECESSED DOWNLIGHT. CONNECT TO EXISTING THREE-WAY SWITCHES AND EXISTING CIRCUIT LP-M1A-12. SEE DRAWING E0.1A FOR PANEL LOCATION. FIELD VERIFY EXACT CIRCUIT NUMBER. NEW 2'x4' RECESSED LIGHTING FIXTURES. CONNECT TO EXISTING CIRCUIT LP-M1A-12. SEE DRAWING E0.1A FOR PANEL LOCATION. FIELD VERIFY EXACT CIRCUIT NUMBER. CONNECT CENTER LAMPS TO EXISTING THREE-WAY SWITCHES S3a. CONNECT TWO OUTER LAMPS TO EXISTING THREE-WAY SWITCHES S3b. EXISTING EMERGENCY BATTERY UNIT TO REMAIN. PROVIDE BRANCH CIRCUIT CONNECTION ON LINE SIDE OF LIGHT SWITCH SERVING TYPE "A" LIGHT FIXTURE. EXISTING FIRE ALARM AUDIBLE/VISUAL DEVICE TO REMAIN. EXISTING PROJECTOR TO REMAIN. NEW EXIT SIGN. CONNECT TO LOCAL LIGHTING CIRCUIT AHEAD OF SWITCHING.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYP. OF 3
AutoCAD SHX Text
AutoCAD SHX Text
TYP. OF 2
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text "A"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "B"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text "A"
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text
%%UFIRST LEVEL NEW POWER AND SYSTEMS FLOOR PLAN ZONE 'A'
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text A108
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A100
AutoCAD SHX Text
EX.
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text A102
AutoCAD SHX Text
SPECIAL EDUCATION
AutoCAD SHX Text A101
AutoCAD SHX Text G003
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text A108
AutoCAD SHX Text
EX.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A100
AutoCAD SHX Text
EX.
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text A102
AutoCAD SHX Text
SPECIAL EDUCATION
AutoCAD SHX Text A101
AutoCAD SHX Text G003
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLES THIS ROOM SERVED FROM
AutoCAD SHX Text
PANELS RP-M11 AND RPIT-M11 AND ARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text WHEN USING THIS DRAWING - PLOT OR PRINT FULL SIZE TO ENSURE CORRECT SCALE. NOTE REDUCED SIZE DRAWINGS ARE NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
"XA"
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING LIGHTING IN THIS ROOM
AutoCAD SHX Text
TO REMAIN
AutoCAD SHX Text
"XA"
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text A
AutoCAD SHX Text Key Plan
AutoCAD SHX Text N
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text E
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text M
AutoCAD SHX Text N
AREA OF WORK
File details come from the government source that posted it. Updated .