17404_ Revised Plans.pdf
PDF 4 MB Posted
- Attached to
- CDC Building 2 Stair Improvements
- Solicitation number
- S-29100-00017404
- Issued by
- Oregon
About this file
This is a revised architectural and structural plan set for a stair replacement project at the Oregon Department of Corrections (DOC) Building No. 2, located at 295 37th Avenue NE, Salem, Oregon 97301. The project, identified as Job No. 2025.0073, involves the removal of an existing wood stair system and its replacement with a new steel stair configuration. The design team includes AC+CO Architecture/Community (Principal Architect Blake Bural, AIA) and MSC Engineers Inc. (Structural Engineer John Carstensen, PE). The project scope includes demolition of the existing wood stair with support rods and guardrails, installation of new steel stringers and pipe railings, concrete landing slabs with broomed finishes, and a cane detection guard. The existing structure is classified as S-2 occupancy (sorting facility/warehouse) with construction type VB, sprinklered, comprising two stories with approximately 21,950 square feet of total area. The plans are prepared in accordance with the 2022 Oregon Structural Specialty Code and 2021 International Building Code. The contract documents include architectural sheets (A2.1, A3.1, A3.2) and structural sheets (S0.1, S1.1) with detailed plans, sections, and connection details. Contractor responsibilities include field verification of all dimensions, shop drawing submittals with 10 business days for design team review, and compliance with special inspection requirements for welding, high-strength bolting, and post-installed anchors.
The structural design specifies concrete mixes with compressive strengths of 3,000 psi for footings and 4,000-6,000 psi for stair elements, with shrinkage-reducing admixtures and air-entrainment requirements. All structural steel conforms to ASTM A992 for wide flanges and ASTM A36 for plates and angles, with fabrication and welding per AISC 360 standards and AWS D1.1 specifications. The project includes new footings (2 feet by 2 feet by 1 foot and 2 feet by 6 feet minimum configurations) with reinforcing bars, new steel columns (HSS 4x4 and 3x3), and landing support systems. Fire sprinkler work is designated as design-build, requiring contractor design under supervision of a Professional Engineer or licensed sprinkler installer with NICET Level III certification and Oregon licensure. The contractor is responsible for obtaining all necessary permits from the Authority Having Jurisdiction. Special inspections are required for structural steel welding, high-strength bolting, and post-installed anchors in accordance with Oregon Structural Specialty Code Section 1705. The seismic design parameters include SS = 0.807 and S1 = 0.404 with Risk Category II and an importance factor of 1.0. Live loads for stairs are specified at 100 psf. No specific contract pricing, award dates, or funding sources are documented in the plan set.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 17404 ITB_GTC_SGC_SPECS.pdf | ||
| Structural Calculations~1.pdf | ||
| Check Off sheet ITB~16.pdf | ||
| 17404_Plans.pdf | ||
| 17404 ADDENDA 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CJA
A2.1
295 37TH AVE NE
SALEM, OR 97301
D.O.C. BUILDING NO. 2
STAIR REPLACEMENT
2025.0073
FEB. 6, 2026
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
UP
CODE ANALYSIS
DESIGN TEAM
OREGON
295 37TH AVE NE
SALEM, OREGON 97301
STRUCTURAL ENGINEER
OWNER
STATE OF OREGON CORRECTIONS
3601 STATE ST
SALEM, OREGON 97310
ATTN: STEVEN CONNER
Steven.E.CONNER@DOC.oregon.gov
DEPARTMENT OF
VICINITY MAP
PROJECT
CORRECTIONS
BUILDING NO. 2
GENERAL
OREGON DEPARTMENT OF CORRECTIONS: BUILDING NO. 2 STAIR REPLACEMENT
PROJECT NUMBER: 2025.0072
STATE OF OREGON 2022 STRUCTURAL SPECIALTY CODE, AMENDMENTS BASED ON 2021 IBC
PRINCIPAL ARCHITECT: BLAKE BURAL, AIA
PROJECT DESCRIPTION: EXISTING WOOD STAIR TO BE REMOVED AND REPLACED WITH NEW STEEL STAIR
USE AND OCCUPANCY CLASSIFICATION (CHAPTER 3)
S-2 OCCUPANCY SORTING FACILITY WAREHOUSE SECT. 311.3
GENERAL BUILDING HEIGHTS AND AREAS (CHAPTER 5)
CONSTRUCTION TYPE: VB, SPRINKLERED
EXISTING HEIGHT: ~34'-0"
BASE ALLOWABLE: 60'-0" MAX, COMPILES TABLE 504.3
EXISTING NUMBER OF STORIES: 2 STORIES
ALLOWABLE: 3 STORIES MAX, COMPLIES TABLE 504.4
EXISTING AREA:
FIRST FLOOR: 20,000 SF
SECOND FLOOR: 1,950 SF
TOTAL: 21,950 SF
BASE ALLOWABLE: 54,000 SF > 21,950 SF, COMPLIES TABLE 506.2
SCALE:1
ENLARGED STAIR PLAN - DEMO
1/4" = 1'-0"
REFERENCE NOTES - DEMO:
1 EXISTING WOOD STAIR TO BE REMOVED
· STEEL SUPPORT RODS FROM ROOF STRUCTURE ABOVE
· 2x WOOD FRAMED GUARDRAIL AND HANDRAIL AS OCCURS
· PLYWOOD DECK OVER 2x WOOD FRAMED LANDINGS
· 2x WOOD TREADS AND RISERS AT STAIRS
· 2x WOOD FRAMED STRINGERS AND PLYWOOD COVER
· 2x WOOD KNEE BRACES
EXISTING WET-PIPE FIRE SPRINKLER LINE TO BE REMOVED TO ALLOW FOR NEW
WORK, F.V. REINSTALL AND MODIFY AS REQUIRED BY GOVERNING CODES, REFER
TO FIRE PROTECTION DESIGN/BUILD DRAWINGS
EXISTING FLOOR DRAIN TO REMAIN
EXISTING EYE WASH STATION TO REMAIN
EXISTING WASHER AND DRYER TO REMAIN
EXISTING STEEL RAILING TO BE REMOVED, CUT EXISTING ANCHORS FLUSH WITH
FINISH FLOOR. PREP FOR REINSTALLATION IN NEW LOCATION
LINE OF FLOOR ABOVE
ABOVE
BOL
(E)
BOL
(E)
BOL
(E)
COL
(E)
COL
(E)
COL
(E)
FE
(E)
STAIR REPLACEMENT
SHEET INDEX
ARCHITECTURAL
A2.1 COVER SHEET AND STAIR PLANS - DEMOLITION & NEW
A3.1 STAIR SECTION AND DETAILS
A3.2 SAFETY ZONE PLAN AND EXISTING CONDITIONS PHOTOS
STRUCTURAL
S.01 GENERAL NOTES AND STAIR PLANS
S1.1 STAIR FRAMING DETAILS
bbural@accoac.com
ATTN: BLAKE BURAL, AIA
PH. 503-581-4114
SALEM, OREGON 97302
1100 LIBERTY STREET SE
AC + CO ARCHITECTURE | COMMUNITY
ARCHITECT
SUITE 200
MSC ENGINEERS INC.
3470 PIPEBEND PL NE, SUITE 120
SALEM, OR 97301
PH. 503-399-1399
CONTACT: JOHN CARSTENSEN, PE
johnc@mscengineersinc.com
GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWINGS.
2. DIMENSIONS ARE TO EXISTING FACE OF WALL, FACE OF NEW FRAMING, AND FACE OF
EXISTING CONCRETE UNLESS NOTED OTHERWISE.
3. DIMENSIONS OF EXISTING CONDITIONS ARE APPROXIMATE AND INTENDED FOR
ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD
VERIFY ALL DIMENSIONS PRIOR TO ACTUAL CONSTRUCTION. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES OR QUESTIONABLE DIMENSIONS PRIOR TO
PROCEEDING WITH AREA OF WORK IN QUESTION.
4. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED.
5. IN CASE OF ANY CONFLICTS IN THE REQUIREMENTS OF THE CONTRACT DOCUMENTS,
THE CONTRACTOR IS REQUIRED TO INCLUDE THE BETTER QUALITY AND LARGER
QUANTITY OF THE WORK.
6. CONTRACTOR AND BIDDERS SHALL USE COMPLETE SETS OF CONTRACT DOCUMENTS;
NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS OR
MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF
CONTRACT DOCUMENTS.
SYMBOL LEGEND:
EXISTING CHAIN-LINK FENCE TO REMAIN
AREA OF EXISTING CONCRETE FLOOR SYSTEM TO BE SAWCUT AND
REMOVED TO ALLOW FOR NEW COLUMN FOOTINGS.
NOTE: CONTRACTOR TO PERFORM SAW CUTTING ON SATURDAYS
TO PREVENT POTENTIAL NOISE AND SILICA HAZARDS
NEW BASE ROCK, AND CONCRETE SLAB, SEAL; DOWEL CONCRETE INFILL
INTO EXISTING CONCRETE SLAB TO REMAIN, REFER TO STRUCTURAL
DRAWINGS
X
EXISTING WALL TO REMAIN
EXISTING COLUMN TO REMAIN, (N) DENOTES NEW COLUMN, REFER TO
STRUCTURAL DRAWINGS. PREP AND PAINT ALL (E) AND (N) COLUMNS SHOWN
COL
(E)
EXISTING DOOR, FRAME AND HARDWARE TO REMAIN(E
EXISTING SURFACE MOUNTED FIRE EXTINGUISHER TO REMAINFE
(E)
EXISTING FLOOR DRAIN TO REMAINFD
(E)
EXISTING STEEL BOLLARD TO REMAINBOL
(E)
FA
(E) EXISTING SURFACE FIRE ALARM TO REMAIN
FD
(E)
SCALE:2
ENLARGED STAIR PLAN - 1ST FLOOR
1/4" = 1'-0" SCALE:3
ENLARGED STAIR PLAN - MEZZANINE
1/4" = 1'-0"
REFERENCE NOTES:
1 EXISTING DOOR/WINDOW TO REMAIN, PROTECT AT ALL TIMES
NEW 11
2" STEEL PIPE HANDRAIL, PAINT
NEW 11
2" STEEL PIPE GUARDRAIL, PAINT, REFER TO
NEW CONCRETE STAIR TREADS, REFER TO STRUCTURAL FOR SPECIFIC MIX. FINISH
TO BE BROOMED PERPENDICULAR TO DIRECTION OF TRAVEL, SEAL.
NEW STEEL STAIR STRINGER, PAINT, REFER TO STRUCTURAL DRAWINGS
NEW LOCATION OF EXISTING STEEL RAIL, PREP AND PAINT, ANCHOR WITH 316"x23 4"
SIMPSON TITEN TURBO CONCRETE SCREW ANCHORS OR APPROVED EQUAL
A3.1
FE (E)
UP
3' -1
0" (E
) L
AN
D
IN
G (1
3) E
Q T
R
EA
D S
AT
T
" E
AC
H
3' -9
(6
) E Q
T R
EA
D
S
AT
1"
E
AC
H
'-6
8'
-1 0"
(E ) L
AN
D
IN
G
'-1
1" 8'
-0
4'-4"
8' -0
'-1 1"
'-1
1" 8'
-0
4'-4"
'-1
1"
'-1
1"
5'-3"
'-1
1"
'-1
1"
4'-0"
CLR
6"4" 6"
'-0
7'
-1 1"
4' -0
(9
) E Q
U
AL
T R
EA
D
S
AT
1"
E
AC
H
8' -3
6'
-0
(1 3)
E Q
T R
EA
D
S
AT
T
" E
AC
H
3'
-9
1' -0
5'
-0
'-0
4' -0
(9
) E Q
U
AL
T R
EA
D
S
AT
1"
E
AC
H
8' -3
6'
-0
(1 3)
E Q
T R
EA
D
S
AT
T
" E
AC
H
3'
-9
1' -0
'-1 1"
1' -0
'-1
1"
7' -1
1"
5'-3"
UP
4' -4
'-0
1' -7
1' -7
4'
-5
CL
CL CL
BOL
(E)
BOL
(E)
BOL
(E)
COL
(E)
COL
(E)
COL
(E)
FE
(E)
FD
(E)
5'-3"
4'-0"
CLR
6"4" 6"
'-1
1"
'-0
2' -6
(1
3) E
Q T
R
EA
D S
AT
T
" E
AC
H
3' -9
1' -0
'-1
1" 8'
-3
4' -5
7' -1
1"
8' -0
'-1 1"
'-1
1" 8'
-0
'-1
1"
4' -4
2'
-7
CL
CL
'-2
1'
-6
8' -3
1'
-7
(E)
COL
(E)
1A A3.1
5'-3"
1A A3.1
1A A3.1
1A A3.1
1' -0
1' -6
CL
2' -6
CL
1' -7
CL
SIM
COL
(N)
COL
(N)
COL
(N)
9 9
7 7
FA (E)
UP
1'-8"
1' -0
1'
-0
2' -0
3'
-6
3' -4
1'
-4
2' -0
6"
1'-4"
8"
3'-3"
2'-0"
5" 7"
5" 7"
CL
5"
4'-10"
2A A3.2
2G A3.2
2B A3.2
2C A3.2
ABOVE
2D A3.2
2E A3.2
2F A3.2
ABOVE
2J A3.2
2H A3.2
2'-0"3'-10"
NEW CONCRETE LANDING OVER STEEL DECK, REFER TO STRUCTURAL FOR SPECIFIC
MIX. FINISH TO BE BROOMED PERPENDICULAR TO DIRECTION OF TRAVEL, SEAL.
NEW 1 12" DIA. STEEL PIPE CANE DETECTION GUARD, 27" MAX HEIGHT, PAINT.
CONTRACTOR TO CORE INTO EXISTING CONCRETE SLAB, EMBED POSTS, AND FILL
WITH GROUT OR ANCHOR WITH 4"x4"x1
2" STEEL BASE PLATE AND 316"x23
4" SIMPSON
TITEN TURBO CONCRETE SCREW ANCHORS OR APPROVED EQUAL
NEW STEEL COLUMN AND BASE PLATE, EXTEND TO UNDERSIDE OF STAIR LANDING.
AT SIM CONDITION, EXTEND AND FASTEN TO UNDERSIDE OF EXISTING GLULAM BEAM
ABOVE AND NEW FOOTING, REFER TO STRUCTURAL DRAWINGS. PREP AND PAINT.
1B A3.1
FIRE SPRINKLER DESIGN/BUILD
· THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, AND
SERVICES NECESSARY FOR PROVIDING AND INSTALLING COMPLETE FIRE SPRINKLER SYSTEMS, AND OTHER WORK
AS SHOWN OR INDICATED
· CONTRACTOR TO DESIGN SYSTEM UNDER DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER OR LICENSED SPRINKLER INSTALLER WITH NICET LEVEL III CERTIFICATION IN THE DESIGN OF WATER BASED SYSTEMS LAYOUT
AND EXPERIENCED IN THIS TYPE OF WORK WITH A VALID LICENSE IN THE STATE OF OREGON
· CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE NECESSARY FIRE SYSTEM PERMITS THROUGH AHJ
10 SECTION OF NEW GUARDRAIL TO BE REMOVABLE REFER TO 5
A3.1
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
BLAKE BURAL
AutoCAD SHX Text
A3.1
295 37TH AVE NE
SALEM, OR 97301
D.O.C. BUILDING NO. 2
STAIR REPLACEMENT
2025.0073
FEB. 6, 2026
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
SCALE:1
STIAR SECTION
1/4" = 1'-0"
GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWINGS.
2. DIMENSIONS ARE TO EXISTING FACE OF WALL, FACE OF NEW FRAMING, AND FACE OF
EXISTING CONCRETE UNLESS NOTED OTHERWISE.
3. DIMENSIONS OF EXISTING CONDITIONS ARE APPROXIMATE AND INTENDED FOR
ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD
VERIFY ALL DIMENSIONS PRIOR TO ACTUAL CONSTRUCTION. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES OR QUESTIONABLE DIMENSIONS PRIOR TO
PROCEEDING WITH AREA OF WORK IN QUESTION.
4. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED.
5. IN CASE OF ANY CONFLICTS IN THE REQUIREMENTS OF THE CONTRACT DOCUMENTS,
THE CONTRACTOR IS REQUIRED TO INCLUDE THE BETTER QUALITY AND LARGER
QUANTITY OF THE WORK.
6. CONTRACTOR AND BIDDERS SHALL USE COMPLETE SETS OF CONTRACT DOCUMENTS;
NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS OR
MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF
CONTRACT DOCUMENTS.
REFERENCE NOTES:
1 EXISTING DOOR/WINDOW TO REMAIN, PROTECT AT ALL TIMES
NEW 11
2" STEEL PIPE HANDRAIL, PAINT
NEW 11
2" STEEL PIPE GUARDRAIL, PAINT, REFER TO
NEW CONCRETE STAIR TREADS, REFER TO STRUCTURAL FOR SPECIFIC MIX. FINISH
TO BE BROOMED PERPENDICULAR TO DIRECTION OF TRAVEL, SEAL.
NEW STEEL STAIR STRINGER, PAINT, REFER TO STRUCTURAL DRAWINGS
NEW LOCATION OF EXISTING STEEL RAIL, PREP AND PAINT, ANCHOR WITH 316"x23 4"
SIMPSON TITEN TURBO CONCRETE SCREW ANCHORS OR APPROVED EQUAL
NEW CONCRETE LANDING OVER STEEL DECK, REFER TO STRUCTURAL FOR SPECIFIC
MIX. FINISH TO BE BROOMED PERPENDICULAR TO DIRECTION OF TRAVEL, SEAL.
NEW 1 12" DIA. STEEL PIPE CANE DETECTION GUARD, 27" MAX HEIGHT, PAINT.
CONTRACTOR TO CORE INTO EXISTING CONCRETE SLAB, EMBED POSTS, AND FILL
WITH GROUT OR ANCHOR WITH 4"x4"x1
2" STEEL BASE PLATE AND 316"x23
4" SIMPSON
TITEN TURBO CONCRETE SCREW ANCHORS OR APPROVED EQUAL
NEW STEEL COLUMN AND BASE PLATE, EXTEND TO UNDERSIDE OF STAIR LANDING.
AT SIM CONDITION, EXTEND AND FASTEN TO UNDERSIDE OF EXISTING GLULAM BEAM
ABOVE AND NEW FOOTING, REFER TO STRUCTURAL DRAWINGS. PREP AND PAINT.
EXISTING STEEL COLUMN TO REMAIN
EXISTING GLULAM BEAM TO REMAIN
A3.1
F.F.E.
0'-0"
F.F.E.
0'-0"
T.O. LANDING
9'-2"
T.O. LANDING
14'-10"
(1 6)
E Q
R
IS
ER
S
AT
8"
E
AC
H
'-2
(1 0)
E Q
R
IS
ER
S
AT
8" E
AC
H
'-8
T.O. LANDING
9'-2"
SCALE:
HANDRAIL/GUARDRAIL DETAIL
2 3/4" = 1'-0" 25073-A3.1-02
NEW 11
2" DIA. VERTICALS, SPACE AT 4'-0" o.c.
MAX
NEW STEEL CHANNEL PER STRUCTURAL
NEW 11
2" DIAMETER RAIL, PAINT
2" 4" M
AX
3'
-0
EQ
U
AL
NEW 11
2" DIAMETER PIPE HANDRAIL, PAINTABOVE NOSING
2'-10"
ABOVE NOSING
3'-6"
2" GAP
NEW WAGNER BRACKET, BAR BEND
(RB14025), PAINT, SPACE AT 4'-0" o.c. MAX
3' -6
2' -1
0" 8"
11 10
SIM
A3.1
A3.1SIM
A3.1
SCALE:3
STAIR CONNECTION
1 1/2" = 1'-0" 25073-A3.1-03
NEW FORM STEEL SHEET TREADS
AND RISER, TYP.
EXISTING SLAB ON GRADE
NEW CONCRETE TREAD INFILL,
REFER TO STRUCTURAL FOR
SPECIFIC MIX. FINISH TO BE
BROOMED PERPENDICULAR TO
DIRECTION OF TRAVEL, SEAL.
NEW STRINGER PER STRUCTURAL,
PAINT
NEW SOLID STEEL RISERS, REFER
TO SPECS, PAINT
NOTE: GUARDRAIL NOT SHOWN
FOR CLARITY
EXST. F.F.E
0'-0"
7" M
AX 11 2"
11"
1"
2" 9"
7"
CONCRETE FOOTING PER
STRUCTURAL
NEW NOSING TO BE PAINTED IN
CONTRASTING YELLOW COLOR
SCALE:4
STAIR CONNECTION
1 1/2" = 1'-0" 25073-A3.1-04
NEW FORM STEEL SHEET TREADS
AND RISER, TYP.
T.O. LANDING
14'-10" (9'-3" AT SIM)
11"
1"
2" 9"
NEW STRINGER PER STRUCTURAL,
PAINT
NOTE: GUARDRAIL NOT SHOWN
FOR CLARITY
NEW STEEL BEAM PER STRUCTURAL,
PAINT
NEW METAL CLIP AT EACH TREAD
PER STRUCTURAL, PAINT
NEW SOLID STEEL RISERS, REFER
TO SPECS, PAINT
NEW NOSING TO BE PAINTED IN
CONTRASTING YELLOW COLOR
NEW CONCRETE TREAD INFILL,
REFER TO STRUCTURAL FOR
SPECIFIC MIX. FINISH TO BE
BROOMED PERPENDICULAR TO
DIRECTION OF TRAVEL, SEAL.
NEW CONCRETE LANDING OVER
STEEL DECK, REFER TO STRUCTURAL
FOR SPECIFIC MIX. FINISH TO BE
BROOMED PERPENDICULAR TO
DIRECTION OF TRAVEL, SEAL.
T.O. LANDING
14'-10"
A3.1
6' -8
1'-0"
7"5"
1B A3.1 3'
-6
2" CLR
BEYOND
A B
SCALE:
REMOVABLE GUARDRAIL DETAIL
5 3/4" = 1'-0" 25073-A3.1-05
4'-4"
T.O. LANDING
14'-10"
3' -6
NEW 11
2" DIA. VERTICALS, SPACE AT 4'-0" o.c.
MAX
NEW 11
2" DIAMETER RAIL, PAINT
NEW STEEL CHANNEL PER STRUCTURAL
3" 3"CL CL CLCL
NEW STEEL PIPE SLEEVE WITH 12" STEEL PIN.
MIN INSIDE DIA. = OUTSIDE DIA. OF GUARDRAIL +
16". ATTACH PER STRUCTURAL
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
BLAKE BURAL
A3.2
295 37TH AVE NE
SALEM, OR 97301
D.O.C. BUILDING NO. 2
STAIR REPLACEMENT
2025.0073
FEB. 6, 2026
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
SCALE:2
EXISTING CONDITIONS PHOTOS
GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWINGS.
2. DIMENSIONS ARE TO EXISTING FACE OF WALL, FACE OF NEW FRAMING, AND FACE OF
EXISTING CONCRETE UNLESS NOTED OTHERWISE.
3. DIMENSIONS OF EXISTING CONDITIONS ARE APPROXIMATE AND INTENDED FOR
ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD
VERIFY ALL DIMENSIONS PRIOR TO ACTUAL CONSTRUCTION. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES OR QUESTIONABLE DIMENSIONS PRIOR TO
PROCEEDING WITH AREA OF WORK IN QUESTION.
4. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED.
5. IN CASE OF ANY CONFLICTS IN THE REQUIREMENTS OF THE CONTRACT DOCUMENTS,
THE CONTRACTOR IS REQUIRED TO INCLUDE THE BETTER QUALITY AND LARGER
QUANTITY OF THE WORK.
6. CONTRACTOR AND BIDDERS SHALL USE COMPLETE SETS OF CONTRACT DOCUMENTS;
NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS OR
MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF
CONTRACT DOCUMENTS.
A
ED FEXISTING FIRE SPRINKLER TO BE REMOVED
AND REINSTALLED AS REQUIRED, REFER TO
FIRE PROTECTION DESIGN/BUILD DRAWINGS
EXISTING STEEL SUPPORT RODS FROM
ROOF STRUCTURE ABOVE TO BE REMOVED
EXISTING FIRE SPRINKLER TO BE REMOVED
AND REINSTALLED AS REQUIRED, REFER TO
FIRE PROTECTION DESIGN/BUILD DRAWINGS
EXISTING STEEL SUPPORT RODS FROM
ROOF STRUCTURE ABOVE TO BE REMOVED
EXISTING STEEL SUPPORT RODS FROM
ROOF STRUCTURE ABOVE TO BE REMOVED
EXISTING FIRE SPRINKLER TO BE REMOVED
AND REINSTALLED AS REQUIRED, REFER TO
FIRE PROTECTION DESIGN/BUILD DRAWINGS
~7 1 2"
T
YP
43" CLR
B C
SCALE:1
SAFETY ZONE PLAN
1/4" = 1'-0"
5' -0
7' -1
1" 7'
-7
21'-3"
8'-0" 8'-0"
'-6
'-0
5'-3"
21'-3"
5'-3" 8'-0"8'-0"
8' -0
'-6
7' -7
'-0
7' -1
1"
'-0
REFERENCE NOTES:
NEW TEMPORARY WALL SURROUNDING CONSTRUCTION AREA. 2x4 STUDS AT 16" OC
WITH 12" PLYWOOD AT OUTSIDE FACE, FRAME UP TO 8'-0" A.F.F. CONTRACTOR TO
PROVIDE CONSTRUCTION ZONE SIGNAGE.
EXISTING DOOR AT MEZZANINE TO BE CLOSED OF FOR DURATION OF WORK2
UP
ABOVE
BOL
(E)
BOL
(E)
BOL
(E)
COL
(E)
COL
(E)
COL
(E)
FD
(E)
COL
(N)
COL
(N)
COL
(N)
FE
(E)
HG J
EXISTING DOOR AT MEZZANINE TO BE
CLOSED OF FOR DURATION OF WORK
EXISTING STEEL SUPPORT RODS FROM
ROOF STRUCTURE ABOVE TO BE REMOVED
EXISTING STEEL RAILING TO BE REMOVED,
CUT EXISTING ANCHORS FLUSH WITH FINISH
FLOOR. PREP FOR REINSTALLATION IN NEW
LOCATION
EXISTING WASHER AND DRYER TO REMAIN
EXISTING FIRE SPRINKLER TO BE REMOVED
AND REINSTALLED AS REQUIRED, REFER TO
FIRE PROTECTION DESIGN/BUILD DRAWINGS
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
BLAKE BURAL
STAIR FRAMING PLAN
1/4" = 1'-0"
S1.1 TYP.
S1.1 TYP.
S1.1 TYP.
S1.1
TY
P.
S1.1
TY
P.
S1.1
TY
P.
S1.1
TY
P.
S1.1
TY
P.
C1 2x
.7
S
TR
IN
GE
R C1
2x
.7 S
TR
IN
GE
R
C12x20.7
MC6x12
L4x4x1
L4x4x1
MC6x12
M C6 x1
LE
DG
ER
NO
TC
HE
D C1
2x
.7 S
TR
IN
GE
R
NO
TC
HE
D
C1 2x
.7
S
TR
IN
GE
R
L4x4x1
L4x4x1
S1.1 TYP.
C1 2x
.7
S
TR
IN
GE
R
NO
TC
HE
D
C1 2x
.7
S
TR
IN
GE
R
FOUNDATION PLAN
1/4" = 1'-0"
CONCRETE LANDING SLAB:
4" THICK W/ W.W.F.4x4-W2.9xW2.9
IN FLAT SHEETS CENTERED IN SLAB
ON 11ga FLAT PLATE, TYP.
HSS
4x
4X
3 16
EX
IST
CO
LU
MN
HSS
3x
3X 3 16
HSS4x4X 3
HSS
4x
4X 3 16
EX
IST
CO
LU
MN
HSS
3x
3X 3 16
HSS4x4X 3
S1.1
TY
P.
S1.1TYP.
2'x2'x1' FOOTING W/ (3) #4 x1'-6" BARS
EA. SIDE, TYP.
2'x6' (MIN.) FOOTING
W/ (4) #4 LONG BARS
F eb
3, 6- 2:
:2 pm
G
JO
BS
-2
5\
O
DO
C
CD
C
BL
DG
S
TA
IR
\2
.D W
G, M
SC
M
SC
E N G
I N E E
R S
SIN
CE
CO
NS
ULT
ING
STR
UC
TUR
AL
EN
GIN
EER
S
3470 P ipeb end Place
NE
Suite 120 Salem
, OR
97301
503.39 9.1399 msc eng inee rsinc.co m
SHEET
DRAWN
REVISIONS
JOB NO.
DATE
251277
FEB. 6, 2026
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
JCP
295 37TH AVE NE
SALEM, OR 97301
D.O.C. BUILDING NO. 2
STAIR REPLACEMENT
S
TR
UCTURAL
DIGITALLY SIGNED
S0.1
GENERAL NOTES
GENERAL REQUIREMENTS:
A. IT IS THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO OBTAIN APPROPRIATE APPROVALS AND
NECESSARY PERMITS FROM CITY, COUNTY, STATE, OR FEDERAL AGENCIES, AS REQUIRED.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION METHODS, TECHNIQUES, SEQUENCING, AND SAFETY REQUIRED TO COMPLETE CONSTRUCTION.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS PRIOR TO PROCEEDING WITH
CONSTRUCTION. ALL DISCREPANCIES SHALL BE APPROVED BY THE ARCHITECT OR ENGINEER OF
RECORD.
D. CONTRACTOR SHALL VERIFY ALL REQUIRED PENETRATIONS ON ARCHITECTURAL, MECHANICAL AND
ELECTRICAL PLANS. ALL DIMENSIONS SHALL BE FIELD VERIFIED AS EARLY AS POSSIBLE.
E. CONTRACTOR SHALL THOROUGHLY REVIEW AND REDLINE ALL SHOP DRAWINGS PRIOR TO SUBMITTAL TO THE ENGINEER AND ARCHITECT. SUBMIT SHOP DRAWINGS IN A TIMELY FASHION TO ALLOW 10 BUSINESS DAYS FOR REVIEW BY DESIGN TEAM. ALL MODIFICATIONS OR COMMENTS MADE DURING REVIEW DO NOT RELIEVE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE PLANS OR
SPECIFICATIONS.
FOUNDATIONS:
A. ALL FOOTINGS TO REST ON FIRM, UNDISTURBED SOIL, OR STRUCTURAL FILL, FREE OF ORGANIC MATERIAL, AND CAPABLE OF SUPPORTING A MINIMUM ALLOWABLE BEARING PRESSURE OF 1,500 psf.
UNDER COMBINED DEAD AND LIVE LOADS.
B. ALL SLABS-ON-GRADE SHALL BE UNDERLAIN BY A MINIMUM OF 6" OF FREE- DRAINING
(LESS THAN 5% PASSING THE NO. 200 SIEVE), WELL GRADED, CRUSHED ROCK. THE
BASE COURSE MATERIALS SHALL BE COMPACTED TO AT LEAST 95% OF MAXIMUM DRY
DENSITY.
REINFORCING PROTECTION:
A. CONCRETE DEPOSITED AGAINST EARTH: 3 INCHES.
B. CONCRETE FORMED SURFACES EXPOSED TO GROUND AND WEATHER:
#5 AND SMALLER BAR - 11
2 INCHES
#6 AND LARGER BAR - 2 INCHES
C. CONCRETE SURFACES NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:
#11 AND SMALLER BAR - 3 4 INCHES
D. SLABS = 34 INCHES
STRUCTURAL STEEL:
A. ALL STRUCTURAL STEEL WIDE FLANGE MEMBERS SHALL CONFORM TO STRUCTURAL STEEL DESIGNATION ASTM A992. ALL STEEL PLATES IN THE SPECIAL MOMENT-RESISTANT FRAMES SHALL CONFORM TO STRUCTURAL STEEL DESIGNATION ASTM A572 (50ksi). ALL OTHER STRUCTURAL STEEL PLATES, ANGLES
AND MISC. SHAPES SHALL CONFORM TO STRUCTURAL STEEL DESIGNATION ASTM A36.
B. ALL HOLLOW STRUCTURAL SECTIONS (HSS) SHALL CONFORM TO ASTM A500, GRADE B DESIGNATION HAVING A MINIMUM YIELD STRENGTH OF 46,000 psi FOR RECTANGULAR SHAPES AND HAVING A MINIMUM YIELD STRENGTH OF 42,000 psi FOR ROUND SHAPES.
C. ALL STRUCTURAL STEEL PIPE SHALL CONFORM TO ASTM A53, GRADE B.
D. FABRICATION AND ERECTION SHALL CONFORM TO THE SPECIFICATIONS SET FORTH IN AISC 360
"SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS," AND AISC 303 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES," AND THE "STANDARD CODE FOR ARC AND GAS WELDING IN
BUILDING CONSTRUCTION."
E. HIGH STRENGTH BOLTS SHALL BE ASTM A325-N, BEARING-TYPE CONNECTION DESIGNED WITH THREADS INCLUDED IN THE SHEAR PLANE. HIGH STRENGTH BOLTS ARE NOT 'PRETENSION,' AND THEREFORE
SHALL BE 'SNUG TIGHT.'
F. ALL OTHER BOLTS NOT DESIGNATED AS HIGH STRENGTH SHALL BE ASTM A307, GRADE A.
G. GALVANIZE ALL EXTERIOR BOLTS IN ACCORDANCE WITH ASTM A153.
H. LOCK NUTS SHALL BE 1F1 100, GRADE B PREVAILING TORQUE TYPE.
I. PLAIN HARDENED WASHERS SHALL BE ASTM F436.
J. BEVELED WASHERS SHALL BE ANSI B18.23.1.
K. WELDING SHALL CONFORM TO AWS D1.1 "STRUCTURAL WELDING CODE - STEEL." WELDING FILLER
METAL SHALL BE AWS A5.1 OR A5.5 E70XX ELECTRODES OR AWS A5.18 ER70S-X. ALL WELDING SHALL BE PERFORMED BY WELDERS AWS CERTIFIED WITHIN THE PAST 2 YEARS FOR THE TYPE OF WELDING PERFORMED. WELDER SHALL PRESENT EVIDENCE OF QUALIFICATION WITHIN THE PAST TWO YEARS.
WELD ELECTRODE E70T-4 IS PROHIBITED.
L. AFTER FABRICATION, BUT BEFORE INSTALLATION, REMOVE RUST SCALE, GREASE AND OIL BY WIRE
BRUSHING AND CHEMICAL TREATMENT.
M. SHOP PRIME STEEL ITEMS WITH ONE HEAVY COAT OF RUST INHIBITING METAL PRIMER, UNLESS STEEL
IS TO BE GALVANIZED.
STRUCTURAL INSPECTION AND TESTING:
A. CONTRACTOR SHALL PROVIDE WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL
AND OWNER PRIOR TO COMMENCEMENT OF WORK AS REQUIRED BY OSSC SECTION 1704.2.3.
B. ALL CONSTRUCTION SHALL BE INSPECTED IN CONFORMANCE WITH THE OREGON STRUCTURAL
SPECIALTY CODE.
C. ALL ITEMS NOTED AS REQUIRING SPECIAL INSPECTION PER THE OREGON STRUCTURAL SPECIALTY CODE IN ACCORDANCE WITH SECTION 1705, SHALL BE PERFORMED BY A QUALIFIED PERSON WHO CAN DEMONSTRATE COMPETENCE FOR THE PARTICULAR TYPE OF CONSTRUCTION BEING INSPECTED. THE SPECIAL INSPECTIONS SHALL BE PERFORMED IN ADDITION TO THE INSPECTIONS REQUIRED BY THE OREGON STRUCTURAL SPECIALTY CODE, THE PLANS AND SPECIFICATIONS, THE ARCHITECT OF RECORD, AND THE BUILDING OFFICIALS.
DESIGN LOADS:
A. STAIR LOADS:
LIVE LOAD = 100 psf
B. SEISMIC DESIGN DATA:
SS = 0.807 S1 = 0.404
SITE CLASS = D
SDS = 0.645 SD1 = N/A
SEISMIC DESIGN CATEGORY D
EQUIVALENT LATERAL FORCE ANALYSIS
RISK CATEGORY = II
C. IMPORTANCE FACTORS:
SEISMIC (Ie) = 1.0
1. THE ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH OSSC SECTION 1705 BY A CERTIFIED SPECIAL INSPECTOR FROM AN ESTABLISHED TESTING AGENCY. FOR MATERIAL
SAMPLING AND TESTING REQUIREMENTS, REFER TO THE MATERIAL SAMPLING AND TESTING
SECTION, THE PROJECT SPECIFICATIONS AND THE SPECIFIC GENERAL NOTES SECTIONS. THE
TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND INSPECTION REPORTS
DIRECTLY TO THE ARCHITECT, ENGINEER, CONTRACTOR AND BUILDING OFFICIAL. ANY
MATERIALS WHICH FAIL TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT. ALL DISCREPANCIES SHALL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO
THE PROPER DESIGN AUTHORITY AND TO THE BUILDING OFFICIAL. THE SPECIAL INSPECTOR
SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL
INSPECTION WAS TO THE BEST OF THE INSPECTOR'S KNOWLEDGE, IN CONFORMANCE WITH THE
APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED
COMPONENTS.
2. CONTINUOUS SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON THE SITE AT ALL
TIMES OBSERVING THE WORK REQUIRING THE SPECIAL INSPECTION. PERIODIC SPECIAL
INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON THE SITE AT TIME INTERVALS
NECESSARY TO CONFIRM THAT ALL WORK REQUIRING SPECIAL INSPECTION IS IN COMPLIANCE.
3. SPECIAL INSPECTION IS NOT REQUIRED FOR WORK PERFORMED BY AN APPROVED FABRICATOR
PER OSSC SECTION 1704.2.5.1.
4. ALL WELDS SHALL BE VISUALLY INSPECTED.
5. ALL COMPLETE PENETRATION WELDS SHALL BE TESTED ULTRASONICALLY OR BY USING ANOTHER
APPROVED METHOD.
6. PERIODIC SPECIAL INSPECTION IS ONLY REQUIRED FOR WELDING OF ASTM A706 REINFORCING
STEEL NOT GREATER THAN NO. 5 USED FOR EMBEDMENTS, PROVIDED THE MATERIALS,
QUALIFICATIONS OF WELDING PROCEDURES AND WELDERS ARE VERIFIED PRIOR TO THE START
OF WORK: PERIODIC INSPECTIONS ARE MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION
OF ALL WELDS IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP WELDING.
7. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED
DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND
FURNISHES EVIDENCE OF COMPLIANCE.
8. SNUG TIGHT
9. PRETENSION
A. TURN OF THE NUT METHOD W/ MATCH MARKING
B. TWIST OFF BOLT
C. DIRECT TENSION INDICATOR
D. CALIBRATED WRENCH (CONTINUOUS INSPECTION)
10. POST INSTALLED ANCHORS REQUIRE PERIODIC INSPECTION (OSSC TABLE 1705.3) UNLESS A MORE
STRINGENT REQUIREMENT IS IMPOSED BY THE INDIVIDUAL ANCHOR'S RESEARCH REPORT.
D. OWNER OR OWNERS REPRESENTATIVE TO RETAIN AN APPROVED SPECIAL INSPECTOR TO OBSERVE AND
APPROVE ALL REQUIRED SPECIAL INSPECTION ITEMS.
E. SPECIAL INSPECTION REPORTS TO BE PROVIDED TO THE BUILDING OFFICIAL & DESIGN PROFESSIONALS
IN A TIMELY MANNER AND IN ACCORDANCE WITH OSSC SECTION 1704.2.4.
DESCRIPTION OF WORK
IBC SECTION 1704
INSPECTION FREQUENCY
CONTINUOUS2 PERIODIC2 COMMENTS
STRUCTURAL STEEL (1705.2)
PREFAB. CONSTRUCTION (1704.2.5)
HIGH STRENGTH BOLTING
WELDING-STAIRS/RAILING SYSTEMS
SHOP WELDING (1705.2.1 & 1705.2.2)
SINGLE PASS FILLET WELDS ≤ 5/16"
FIELD WELDING (1705.2.1 & 1705.2.2)
SINGLE PASS FILLET WELDS ≤ 5/16"
POST INSTALLED ANCHORS (1705.1.1 & TABLE 1705.3 (4))
ADHESIVE ANCHOR INSTALLATION
MECHANICAL ANCHOR INSTALLATION
REQUIRED SPECIAL INSPECTIONS1
REF. NOTE 7
A3258,9, A490
REF. NOTE 4
REF. NOTE 4
X X
X
X
X X
REF. NOTE 10
REF. NOTE 10
CODES AND STANDARDS:
A. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 OREGON
STRUCTURAL SPECIALTY CODE AND 2021 EDITION INTERNATIONAL BUILDING CODE INCLUDING
REFERENCE STANDARDS LISTED BELOW:
· AMERICAN NATIONAL STANDARDS INSTITUTE/AMERICAN SOCIETY OF CIVIL ENGINEERS -
(ANSI/ASCE 7-2016)
· AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC 15TH EDITION)
· AMERICAN WELDING SOCIETY STANDARDS FOR WELDING AS MODIFIED BY AISC SPEC. (AWS D1.1 -
2015, AWS D1.4 - 2018)
· AMERICAN CONCRETE INSTITUTE (ACI 301 - 2016, ACI 318 - 2019)
REF. NOTE 3
CONCRETE:
A. ALL CONCRETE WORK SHALL CONFORM TO OSSC CHAPTER 19, "CONCRETE," ACI 318, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE," ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE," ACI 117, "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS."
B. SPECIAL INSPECTIONS: ALL CONCRETE MIXES REQUIRE SPECIAL INSPECTION UNLESS OTHERWISE
NOTED.
C. REINFORCING: ALL CONCRETE SHALL BE REINFORCED UNLESS SPECIFICALLY NOTED IN PLANS AND DETAILS. WHERE REINFORCING IS NOT INDICATED, PROVIDE REINFORCING AS SHOWN IN SIMILAR
DETAILS AND VERIFY PLACEMENT WITH ENGINEER.
D. CONCRETE EXPOSED TO WEATHER: ALL CONCRETE MIXES EXPOSED TO WEATHER SHALL BE
AIR-ENTRAINED WITH AN AIR CONTENT OF 5% ±1%.
E. CONCRETE CAST AGAINST EXISTING: WHERE CONCRETE IS CAST AGAINST EXISTING OR PREVIOUSLY
CURED CONCRETE, ROUGHEN CONTACT SURFACES TO 1/4" AMPLITUDE AND CLEAN SURFACE OF
LAITANCE, FOREIGN MATTER, PAINT AND LOOSE PARTICLES. APPLY LIQUID BONDING AGENT ON
SURFACE OF EXISTING PRIOR TO PLACEMENT.
F. FLY ASH: PORTLAND CEMENT CONTENT MAY BE REPLACED WITH UP TO 25% FLY ASH (BY WEIGHT) CONFORMING TO ASTM C618 (INCLUDING TABLE 2A) TYPE F OR TYPE C, PROVIDED THAT MIX STRENGTH
IS SUBSTANTIATED BY TEST DATA.
G. SLAG: PORTLAND CEMENT CONTENT MAY BE REPLACED WITH UP TO 25% (BY WEIGHT) SLAG CEMENT CONFORMING TO ASTM C989, PROVIDED THAT MIX STRENGTH IS SUBSTANTIATED BY TEST DATA.
H. ADMIXTURES: WATER REDUCING ADMIXTURES CONFORMING TO ASTM C494 MAY BE USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND SHALL BE INCORPORATED IN THE
CONCRETE MIX DESIGN SUBMITTAL.
I. SLUMP: SLUMP REQUIRED FOR PROPER PLACEMENT SHALL BE DETERMINED BY THE CONTRACTOR AND SUPPLIER BASED UPON DELIVERY TIME AND METHOD OF PLACEMENT AND INCLUDED IN THE MIX DESIGN
SUBMITTAL INCLUDING INFLUENCE OF ADDITIVES.
J. WATER: WATER SHALL BE CLEAN AND POTABLE. NO WATER SHALL BE ADDED IN FIELD UNLESS SPECIFICALLY APPROVED IN WRITING BY THE CONCRETE SUPPLIER AS A PROPORTION ALLOTTED WITHIN
APPROVED CONCRETE MIX DESIGN.
K. SUBMITTALS: CONTRACTOR SHALL SUBMIT A COPY OF EACH CONCRETE MIX DESIGN AND (30) 28-DAY BREAK TEST RECORDS TO ENGINEER FOR REVIEW AND COMMENT. ALLOW SUFFICIENT TIME FOR REVIEW
AND APPROVAL BEFORE DELIVERY.
L. CONCRETE MIX DESIGNS:
COARSE
AGGREGATE
SIZE
MAXIMUM
WATER/CEMENT
RATIO
LOCATION ADD’L
NOTES
MINIMUM
COMPRESSIVE
STRENGTH (F'c)
NOTES:
1. REFER TO ADDITIONAL NOTES UNDER “STAIR CONCRETE”
2. THIS MIX SHALL HAVE A SHRINKAGE LIMIT OF 0.035% AT 28-DAYS.
3. SPECIAL INSPECTION NOT REQUIRED
FOOTINGS
STAIRS
.46
.44 3,000 4,000
NON-SHRINK GROUT 1
2" .44 6,000 2,3
3 4"
STAIR CONCRETE:
A. MAXIMUM WATER CONTENT: 260 PCY
B. POZZOLAN (FLY ASH OR SLAG) CONTENT: 10% MIN - 25% MAX (BY WEIGHT)
C. DESIGN SHALL INCLUDE 0.5 to 1.5 GALLON PER CY OF SHRINKAGE REDUCING ADMIXTURE (“SRA”) SUCH
AS “ECCLIPSE” BY GCP APPLIED TECHNOLOGIES OR APPROVED ALTERNATIVE. SRA MAY BE SUBSTITUTED WITH SHRINKAGE COMPENSATING ADMIXTURE (“SCA”) PROVIDED THE CEMENT TYPE AND MIX DESIGN
ARE IN CONFORMANCE WITH PRODUCT MANUFACTURER’S SPECIFICATIONS.
D. APPLY COMPATIBLE SEALER AND DENSIFIER PER PROJECT SPECIFICATIONS
3 4"
AutoCAD SHX Text
OREGON
AutoCAD SHX Text
93460SE
EXPIRES: DECEMBER 31, 2025
1/8 2-6TYP.
STAIR STRINGER
PER PLAN
3/16
RAILING POST
PER ARCH.
2"
STAIR STRINGER
PER PLAN
2"
4"x11
4"x9" 12ga. CLIP EA. TREAD
2" CONCRETE TREAD
12ga. STEEL PAN TREADS
TYPICAL TREAD CONNECTION @ STAIR STRINGERS
1 1/2" = 1'-0"
S1.1
STAIR STRINGER CONNECTION @ LANDING BEAM
1 1/2" = 1'-0"
S1.1
3/16 1-12
L3x3x3
16 SLAB
SUPPORT, TYP.
4" LANDING SLAB PER PLAN PJP, GRIND
SMOOTH
3"x31 2"x3
8" PLATE
W/ 5 8"Ø BOLT
TYP. 5"x9"x3
8" PLATE
W/ (4) 58"Ø BOLT
BEAM PER PLAN
3/16
2"x5"x3
8" PLATE
W/ (2) 58"Ø BOLT
POST PER PLAN
W/ 14" CAP PLATE
2"
3"x31 2"x3
8" PLATE
W/ 58"Ø BOLT
STAIR STRINGER CONNECTION @ LANDING BEAM
1 1/2" = 1'-0"
S1.1
STRINGER PER PLAN
STRINGER PER PLAN
ANGLE PER PLAN
ANGLE PER PLAN
4" LANDING SLAB PER PLAN
L3x3x3
16 SLAB
SUPPORT, TYP.
3/16 1-12
TYP.
STRINGER CONNECTION @ SLAB
1 1/2" = 1'-0"
S1.1
EXIST. CONCRETE SLAB
RAILING POST
PER ARCH.
3/16
4" BASE PLATE
& CAP PLATE
STAIR STRINGER
PER PLAN
L3x3x3 16 x6"
W/ (2) 58"∅ SIMPSON
STRONG-BOLT 2
WEDGE ANCHORS
3/16 3-SIDES.
1' -0
2'-0" (4) #4 LONG. BARS
7"
CONCRETE FTG.
STAIR STRINGER
PER PLAN
2"
L3x3x3
16 SLAB
SUPPORT, TYP.
4" LANDING SLAB PER PLAN
3"x31 2"x3
8" PLATE
W/ 58"Ø BOLT
BEAM PER PLAN
CONNECTION
PER DETAIL 7/S1.1
POST BEYOND
PER PLAN
STRINGER PER PLAN
ANGLE PER PLAN
PJP, GRIND
SMOOTH
STAIR STRINGER CONNECTION @ LANDING BEAM
1 1/2" = 1'-0"
1/4
NOTCHED STRINGER PER PLAN
EXIST. GLB.
5"x8"x1
4" PLATE
W/ (4) 14"Ø x3" SIMPSON SDS SCREWS
4"x5"x1
4" TAB EA. SIDE
W/ 58"Ø THRU-BOLT IN 11
16"x2" HOLE
1" C
LR
2"x5"x3
8"
W/ (2) 58"Ø BOLT
1" 3"
1"
1"
2"
1" 3"
1"
POST PER PLAN BEAM PER PLAN
4" LANDING SLAB
PER PLAN
L4x4x1
4 W/ (2) 12"Ø BOLT
BEAM CONNECTION @ POST
1 1/2" = 1'-0"
S1.1
STAIR STRINGER
PER PLAN
2"
STAIR STRINGER CONNECTION @ LANDING BEAM
1 1/2" = 1'-0"
L3x3x3
16 SLAB
SUPPORT, TYP.
4" LANDING SLAB PER PLAN
TYP.
5"x9"x3
8" PLATE
W/ (4) 58"Ø BOLT
2"x5"x3
8" PLATE
W/ (2) 58"Ø BOLT
POST PER PLAN
W/ 14" CAP PLATE
STRINGER PER PLAN
1" 3"
1"
1"
NOTCHED STRINGER PER PLAN
4" LANDING SLAB
PER PLAN
L3x3x1
EXIST. 2x6 PLATE
EXIST. 2x6 STUD WALL
EXIST. 2x BLOCKING
EXIST.
OPEN-WEB
JOIST
EXIST. GLB.
1/4
BEAM CONNECTION @ EXIST. BEAM
1 1/2" = 1'-0"
S1.1
LEDGER CONNECTION @ BEAM
1 1/2" = 1'-0"
S1.1
EXIST. 2x6 PLATE
EXIST. 2x6 STUD WALL
EXIST. 2x BLOCKING 4" LANDING SLAB
PER PLAN
EXIST. GLB.
LEDGER PER PLAN
W/ 14"Ø x41
2" SIMPSON SDS SCREWS @ 8" OC, STAGGERED
2"x3"x1
4" TAB
W/ 12"Ø BOLT ANGLE PER PLAN
BEAM CONNECTION @ EXIST. BEAM
1 1/2" = 1'-0"
S1.1
EXIST. 2x6 PLATE
EXIST. 2x6 STUD WALL
EXIST. 2x BLOCKING
4" LANDING SLAB
PER PLAN
EXIST. GLB.
A
A L3x3x3
16 SLAB SUPPORT
CONCRETE FTG CONNECTION @ POST
1 1/2" = 1'-0"
S1.1
SIZE & REINFORCING PER PLAN
EXIST.
CONCRETE SLAB
(4) 58"∅ SIMPSON
STRONG-BOLT 2 WEDGE
ANCHORS
W/ LEVELING NUTS,
EMBED=35
8"
2"
TYP.
2"
TY
P.
10"x10"x3
8" BASEPLATE
@ 4x4 COLUMN 9"x9"x3
8" BASEPLATE @
3x3 COLUMN
1/4
SECTION A-A
POST PER PLAN
A A
L4x4x1
4 BEYOND
W/ (2) 12"Ø ERECTION BOLTS
4" CLOSURE PLATE
(2) #4 x1'-8" DOWELS
EA. SIDE, DRILL &
DRIVE 5" INTO EXIST.
#4 x1'-8" DOWELS @ 12" OC
EA. SIDE, DRILL & DRIVE 5"
INTO EXIST.
12ga. CLOSURE ANGLE
12ga. CLOSURE ANGLE
A
A
2"
3"
2"
2"
1"
3"
2"
2"
2"
2"
2"
2"
2"
4" LANDING SLAB
PER PLAN
3/16
4" CLOSURE PLATE
LEDGER PER PLAN
SECTION A-A
4" LANDING SLAB
PER PLAN
SECTION A-A
2"
1" 3"
2"
2"11
2"
2"
2"
2"
2"
LEDGER PER PLAN
F eb
3, 6- 2:
:2 pm
G
JO
BS
-2
5\
O
DO
C
CD
C
BL
DG
S
TA
IR
\2
.D W
G, M
SC
M
SC
E N G
I N E E
R S
SIN
CE
CO
NS
ULT
ING
STR
UC
TUR
AL
EN
GIN
EER
S
3470 P ipeb end Place
NE
Suite 120 Salem
, OR
97301
503.39 9.1399 msc eng inee rsinc.co m
SHEET
DRAWN
REVISIONS
JOB NO.
DATE
251277
FEB. 6, 2026
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
JCP
295 37TH AVE NE
SALEM, OR 97301
D.O.C. BUILDING NO. 2
STAIR REPLACEMENT
S
TR
UCTURAL
DIGITALLY SIGNED
S1.1
AutoCAD SHX Text
OREGON
AutoCAD SHX Text
93460SE
EXPIRES: DECEMBER 31, 2025
| Architectural Set |
| Sheets and Views |
| 25073-A3.2-A3.2 |
| Structural Set |
| Sheets and Views |
| 251227 020326-S0.1 |
| 251227 020326-S1.1 |
File details come from the government source that posted it. Updated .