Attachment_B.pdf

PDF 10 KB Posted

Attached to
Maintenance for 16 Lethal/Non-Lethal Fences Federal contract opportunity
Solicitation number
15BNAS18QRCA00100
Issued by
Department of Justice Bureau of Prisons Central Office

About this file

Fence Parts List

View the file

Other files for this federal contract opportunity

Other files attached to Maintenance for 16 Lethal/Non-Lethal Fences, newest first.
File Type Posted
SOW_05232018.pdf PDF
FOB_Questions__3.docx DOCX document
SOW_05112018.pdf PDF
Questions_and_Answers_2_post.pdf PDF
Amendment_2.pdf PDF
SOW.pdf PDF
RFQ_Updated.pdf PDF
PPQ.pdf PDF
Instructions_and_Evaluation.pdf PDF
Q&A.pdf PDF
Amendment_1.pdf PDF
SOW_05032018.pdf PDF
Attachment_A.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment B

Part Name Description

Energizer Cabinet - Complete Assembly

Cabinet consists of a Lethal and Non-Lethal Energizer capable of operating an entire perimeter fence. The energizer has the capability of switching between lethal and non-lethal modes along with dividing the perimeter into separate zones

Isolation Switch - Complete Assembly Isolation Switch is utilized to ground the entire perimeter fence. When grounded, any stray voltage on the fence will dissipate

Rodent Energizer - Complete Assembly Rodent Energzier is utilized to deter animals from climbing onto the Electric Fence and potentially causing nusaince alarms and hurting the animal

Sallyport Controller - Complete Assembly The Controller consists of a touchscreen and all associated equipment to monitor and control the Lethal/Non-Lethal perimeter fence system

Cabinet with Custom Turret for Monitor The cabinet where the monitor and equipment is installed

Allen Bradley Software Software that is required to run the custom monitoring and controlling software

GUI Map Graphic representation of the Lethal/Non-Lethal perimeter fence system

ElectroGuard 5000 Custom Software Custom software with the capability of monitoring and controlling the Lethal/Non- Lethal perimeter fence system

Power Supply Powers the cabinet

PLC PLC controls the inputs and outputs and relays the information to the controller

PLC Input Module x 2 The input module brings notifications to the PLC

PLC Output Module The output module sends notifications to equipment

PLC Power Supply Powers the PLC, input and output modules

PLC End Cap Connects the entire PLC

TTL D/O Module Allows the switching between fiber connections

Programming Cable Cable utilized to upload software to the PLC

Plug-in Relay Drives the siren

Allen Bradley Touchscreen Computer Computer is the graphic interface that monitors and controls the Lethal/Non-Lethal Electrified Fence System

Siren Alerts users when there is an alarm

Housekeeping Pad Pad keeps equipment off the ground and allows for cabling below the cabinet

Admin Controller - Complete Assembly The Controller consists of a touchscreen and all associated equipment to monitor and control the Lethal/Non-Lethal perimeter fence system

Cabinet with Turret and Monitor cutout The cabinet that the Controller is installed in

Allen Bradley Touchscreen Computer is the graphic interface that monitors and controls the Lethal/Non-Lethal Electrified Fence System

GUI Map Graphic representation of the Lethal/Non-Lethal perimeter fence system

Siren Alerts users when there is an alarm

Admin Equipment Room Rack - Complete Assembl The cabinet consists of a database computer to review the history of the fence system along with networking equipment and the Remote Annunciation Notification

Equipment Room Cabinet The cabinet where all of the equipment is installed

Cisco Network Switch Network switch that allows all of the controllers to communicate

Black Box Fiber Module The fiber module is where the fiber is connected at each end

RANS PLC Output Module x 4 The output modules allow for each zone of the perimeter to be announced over the RANS System

RANS PLC Power Supply The power supply provides power to the complete RANS PLC system

RANS PLC Ethernet Adapter Connects the RANS module to the PLC

Power Supply - IDEC The power supply provides power to the entire Equipment Room Cabinet

Database PC Standard computer with software to review the Perimeter Fence history

Printer Printer is utilized to make hard copies of the Perimeter Fence history

Less-Lethal / Lethal Fence Parts list

Attachment B

Fence Structure Components The physical structure that creates a secure facility

12' Strain Post with Mounting Tabs A strain post, also known as the end of the zone, is utilized to create tension on all wires within a zone.

12' Corner Post with Mounting Tabs A corner post acts similar to a strain post but is not an inline post. Corner posts typically connect two different zones at an angle

Part Name Description

12' Inline Post with Mounting Tabs Inline posts hold electrified wire and ensure the wire stay taught

Insulator Insulators are used to hold the electrified wire away from the post

Insulator Pins (including nuts) Pins are used to hold the insulators to the fence posts

Insulator Springs Springs are used to hold the electrified wire to the

Electrified Wire Electrified Wire is strung taught around the entire perimeter and is energized to deter an escape

Electrified Tensioner Tensioners are used to create tension within a zone

Stainless Steel Crimps Crimps are used to splice stainless steel wire to itself

Rodent Insulator Insulators are used to hold the rodent wire

Rodent Pin (including nut & washer) Pins are used to attached a rodent insulator to a post

Rodent Tensioner Tensioners are used to create tension within a zone

Field Lightning Arrestors Lighting Arrestors are used to prevent power surges that could potentially damage equipment

Copper Jumper Wire (unbent) Jumper wire is utilized to move a phase of electricity from one stainless steel wire to another

Copper Crimp Crimps are used to connect jumper wire to the electrified wire

HT Cable (Energizer to Fence) Cable is used to run power from the Energizer cabinet to the electrified fence line

Traffic Light Traffic Light is an indicator for personnal to understand the status of the Lethal/Non- Lethal Fence system

Warning Signs Signs are used to warn individuals on the inside and outside of the facility that there is a dangerous Electrified Fence System around the perimeter of the prison

Stereo Doppler Microwave - Sensor Only Microwaves are used to pick up motion within the Sallyport

Ground Cable - Main (Price vary daily) Ground Cable buried around the entire perimeter to create one large grounding grid

Ground Cable - Whip (Price vary daily) Ground cable used to connect the main ground to each individual post

CAD Weld to post Welds are used to connect ground whips to posts

CAD Weld Main Cable Welds are used to splice the main ground cable

CAD Weld Whips to Post Welds are used to connect ground whips to the main ground cable

Specialty Retrofit Components - GDI System

12' Angle with Mounting Holes - Post Modificatio Angle is used to attach to an existing post to retrofit a GDI Electrified Fence System to a Detekion Security Electrified Fence System

Slide Lock Set - Sallyport Gates Locks are utilized at the Sallyport Gates to secure the perimeter system and prevent any unauthorized access