2018-05-15_Revised_G1_2.pdf
PDF 870 KB Posted
- Attached to
- Payson Ranger Station
- Solicitation number
- 12-94TZ-18-R-0002
About this file
2018-05-15 Revised G1_2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Clarifying_Questions_Response_5.22.18.xlsx | XLSX spreadsheet | |
| 1294TZ18R0002_Amendment_0003_5.22.18.pdf | ||
| Responses_to_Questions_5.16.18.xlsx | XLSX spreadsheet | |
| Sheet_A0.3.pdf | ||
| 2017-11-8_LEED_Checklist_Payson.pdf | ||
| Sheet_A7.2.pdf | ||
| 104423_Signage.pdf | ||
| 1294TZ18R0002_Amendment_0002_5.16.18.pdf | ||
| 1294TZ18R0002_5.11.18.pdf | ||
| 1294TZ18R0002_Amendment_0001_5.11.18.pdf | ||
| Payson_Ranger_Station_Site_Visit_Sign_In_(5.1.18).pdf | ||
| Past_Performance_Questionnaire_Attch_H_4.25.18.pdf | ||
| Question_Template_Attch_G.xlsx | XLSX spreadsheet | |
| Addendum_1.zip | ZIP file | |
| 1294TZ18R0002_4.18.18.pdf | ||
| 1294TZ18R0002_4.16.18.pdf | ||
| 1294TZ18R0002_4.13.18.pdf | ||
| Attachments_A-H.zip | ZIP file |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CODE REVIEW - 2012 IBC
Title, Description of Use :
Occupancy Classification (Section 302) :
Offices for USDA/FS District Ranger Station
Business Group B - Civic Administration
Assembly Group A3 (Nonseparated Accessory Occupancy)
Type of Construction (Section 602) : V-B
Allowable Area (At)
9,000 sf / storyGroup B "Business"
Actual Building Height and Floor Area :
Height :
Floor Area :
Group B "Business"
Group A3 "Assembly"
Total Floor Area:
20' - 1"
11,995 sf
980 sf
12,975 sf
Fire Resistance Ratings (Table 601 & 602) : TYPE V-B
Primary Structural Frame 0 Hours
Bearing Walls
Exterior
Interior
0 Hours 10 FT; 1 Hour < 10 FT
0 Hours
Non-Bearing Walls
Exterior (Table 602)
Interior
0 Hours 10 FT; 1 Hour < 10 FT
0 Hours
Floor Construction 0 Hours
Roof Construction 0 Hours
Mixed Use and Occupancy (508.3) :
508.3.1 Occupancy Classification: "Nonseparated occupancies shall be individually classified in accordance with Section 302.1. The requirements of this code shall apply to each portion of the building based on the occupancy classification of that space. In addition, the most restrictive provisions of Chapter 9 which apply to the nonseparated occupancies shall aply to the total nonseparated occupancy area."
Chapter 9 - Fire Protection Systems: Group A-3 - Most Restrictive (903.2.1.3) Fire Area Exceeds 12,000 SF, Requires Automatic Sprinkler System (907.2) Fire Alarm: Provide Occupany Notification Appliance Activated Upon Sprinkler Waterflow.
Width of Exits (1005.3.2) : 260 x .15" = 39" required; 48" provided
Distance to Exits (Table 1016.2) : Less than 300 ft, actual maximum distance: 89 ft
Number of Exits (Table 1019.1) :
2 exits required; 6 exits provided Group B "Business"
Group A3 "Assembly" 2 exits required; 2 exits provided
Plumbing Fixtures (Table 2902.1) :
(Per Group B "Business" Occupancy)
119 / 2 = 60 Male, 60 Female
Water Closets : 1/25 for first 50, 1/50 for remainder
Lavatories : 1/40 for first 80, 1/80 for remainder
Required Provided
M F M F
Water Closets
Urinals
Lavatories
Drinking Fountains
Service Sink
Drinking Fountains : 1/100
2 2
1 1
3 3 4 4
0 0 0 0
2 2 4 4
Allowable Stories
2 stories
Allowable Height (Table 503): 40 feet
Building Limitations:
Building Area Modifications - General (Section 506.1)
"The building areas limited by Table 503 shall be permitted to be increased due to... automatic sprinkler system protection (Is) in accordance with Equation 5-1:
Aa = {At + [At × If] + [At × Is]}
Aa = Allowable building area per story (square feet).
At = Tabular building area per story in accordance with Table 503 (square feet).
If = Area increase factor due to frontage as calculated in accordance with Section 506.2.
Is = Area increase factor due to sprinkler protection as calculated in accordance with Section 506.3."
Automatic Sprinkler Increase (506.3) Is = 3 when no more than one story above grade plane
Aa = {9,000 + [ 9,000× 0 ] + [ 9,000 × 3 ]}
ALLOWABLE BUILDING AREA Aa = 36,000 SF per story
Stories : 1 story
Exterior (704.10) 0 Hours 10 FT; 1 Hour < 10 FT
Exits and Occupant Loads (Table 1004.1.1) :
Group B "Business" (100 gross sf / occupant)
Group A3 "Assembly - Concentrated" (7 net sf / occupant)
11,894 sf / 100 sf/ occupant = 119 occupants
980 sf / 7 sf/ occupant = 140 occupants
259 occupants
ZONING CODE REVIEW - TOWN OF PAYSON, AZ
Zone :
Use:
R1-75
Business / Administrative Office / USFS
Minimum Lot Size : 175,000 SF
Permitted Coverage : _________
Yard Setbacks :
Side Yard : 30' - 0"
Front Yard : 60' - 0"
Rear Yard : 60' - 0"
Rear Yard : 30' - 0"
Height Limit : 35' - 0"
Architectural Approval Board: See Payson Design Review Manual
Required Bufferyards: C or TBD per 154-03-002 Require Landscape Screen: TBD per 154-03-002
Parking Calculation:
Business - Professional 1 space / employee x 94 employees = 94 spaces Visitor's 1 space / 250 sf x 11,995 sf = 48 spaces Conference 1 space / 75 sf x 980 sf = 14 spaces
Total Parking Spaces Required: 156 spaces Total Parking Spaces Provided: 65 spaces, 4 ADA
Bicycle Parking:
Total Space Required 0 spaces Provided: 12 spaces
Outdoor Use Area (Alternate 1): 1,056 sf
Fire Protection :
Fully Sprinklered Yes Fire Alarm System Yes
980 SF
A3 OCCUPANCY
1 occ. / 7 net sf 140 occ.
11894 SF
B OCCUPANCY
1 occ. / 100 gross sf 119 occ.
EXIT
EXIT EXIT
EXIT
EXIT
EXIT
55' TRAVEL 70 occ
57' TRAVEL 70 occ
79' TRAVEL
11 occ
86' TRAVEL
10 occ 77' TRAVEL
18 occ 93 occ
89' TRAVEL
o cc
14 occ
52' TRAVEL
31 occ
84' TRAVEL
EXIT
FEC
FEC
FEC
FEC
1056 SF
OUTDOOR USE (ALTERNATE 1)
PATH TO PUBLIC WAY
PA
TH
T O
PU
BL
IC
W
AY
PATH TO PUBLIC WAY
PA
TH
T O
PU
BL
IC
W
AY
PATH TO PUBLIC WAY
OPEN
OFFICE HOT
SHOTS
HUDDLE
ROOM
ADA MEN'S
RESTROOM
ADA
WOMEN'S
RESTROOM
GIS
MAPPING
ROOM
OPEN
OFFICE
FUELS &
FIRE
OPEN
OFFICE
FUELS &
FIRE
OFFICE 4
ELEC
W/H
PRINTER
ALCOVE
CONFERENCE
CORRIDOR
VENDING &
MUD ROOM
COMMONS
BREAK
FILE
TRASH
ALCOVE
WOMEN'S
RESTROOM
MEN'S
RESTROOM
SUPPLY
CLOSET
OPEN
OFFICE
ECO/WILD/TIM/ENG
HUDDLE
ROOM
ELEC
JAN
STORAGE
ADA
WOMEN'S
RESTROOM
ADA MEN'S
RESTROOM
CONFERENCE
ENTRY
LOBBY
OPEN
OFFICE
ADMIN/REC
SECURED
STORAGE
OFFICE 1
OFFICE 2
EVIDENCE
OFFICE 3
CONFERENCE
IT
FIRE RISER
101 ADA
WOMEN'S
RESTROOM
ADA MEN'S
RESTROOM
HUDDLE
ROOM
VISITORS
LOBBY
RECEPTION
C
D
A
B
A
B
B
A
EMERGENCY EGRESS
EXITING ROUTE STARTING POINT
EXITING ROUTE
FIRE EXTINGUISHER CABINET
LOCATION, MAX 75' TRAVEL DISTANCE
(2012 IBC TABLE 906.3 (1)
FIRE/ EXITING LEGEND
FEC
EXIT
CL OF SIGN,
TYPICAL
NOTES:
1. ALL TOILET ROOM SIGNS WILL BE LOCATED TO CENTERLINE OF
DOOR, MOUNTED AS SHOWN ABOVE
2. CONTACT ARCHITECT FOR ANY DISCREPENCY IN MOUNTING SIGNS
5'
0"
CL OF SIGN,
TYPICAL
5'
0"
9"
9"
WOMEN
PICTOGRAM; WHITE; MALE
OR FEMALE AS REQUIRED.
SEE SCHEDULE
GRADE 2 BRAILLE
6" 1/
2" 1/2"1/2"
1" 1"
NOTES:
1. LOCATE SIGN TO CENTERLINE OF DOOR
2. MOUNT SIGN 5'-0" A.F.F. TO CENTERLINE
5/8" HIGH WHITE LETTERS
ON BACKGROUND TO
MATCH SW 7714
6"
9"
WOMEN
PICTOGRAM; WHITE; MALE
OR FEMALE AS REQUIRED.
SEE SCHEDULE
GRADE 2 BRAILLE
1/ 2"
1/2"
1" 1"
NOTES:
1. LOCATE SIGN TO CENTERLINE OF DOOR
2. MOUNT SIGN 5'-0" A.F.F. TO CENTERLINE
5/8" HIGH WHITE LETTERS
ON BACKGROUND TO
MATCH SW 7714
1 1/2" 1 1/2"
0' 4' 8' 16' N
N
TRUEPROJECT
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S ig ned . .
CE
RT
I FICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2019
A R C H
IT
EC
TS
JOB NO:
DATE:
REVISIONS
DRAWN BY:
CO
NS
UL
TA
NT
S
No rth
C ou rt Av en ue
Tu cs on , A riz on a
0.
5.
Fa x 5
.7
.6 ww w.
bw sa rc hs .c om
B U
R N
S W
A L D
-H O
P K
IN
S
S H
A M
B A
C H
A R
C H
IT
E C
T S
5/
/2
:0 5:
A
M
Construction Documents
G1.2
CODE ANALYSIS & CODE
REVIEW PLAN
02/23/2018 1622.000
UN
IT
ED
S
TA
TE
S
FO
RE
ST
S
ER
VI
CE
PA
YS
ON
D
IS
TR
IC
T
RA
NG
ER
S
TA
TI
ON
CI
VI
L
Te tra
T ec h
5- B
W . M ai n
St re et Pa ys on
, A Z
Ph on e:
(9
) 4
-4
Em ai l:
Fo rre st .S wi tze r@ te tra te ch .c om
LA
ND
SC
AP
E No rri s
De si gn
E
M ad is on
S tre et Ph oe ni x, AZ
Ph on e:
(6
) 2
-9
Em ai l:
m es te s@ no rri s-de si gn .c om
ST
RU
CT
UR
AL
Sc hn ei de r &
A ss oc ia te s
E 9t h St re et
Tu cs on , A
Z
Ph on e:
(5
) 5
-8
Em ai l:
rs ch ne id er sa st ru ct ur al .c om
M
EC
H/
PL
UM
B/
FI
RE
Ke lly
W rig ht
A ss oc ia te s
E T an qu e Ve rd e
Rd Tu cs on
, A Z
Ph on e:
(5
) 8
-1
Em ai l:
bu zz kw m ec h.
co m
EL
EC
TR
IC
AL
M
En gi ne er in g
W
S un se t R d Tu cs on
, A Z
Ph on e:
(5
) 2
-1
Em ai l:
eg iro n@ m
3e ng
.c om
E H
IG
HW
AY
PA
YS
ON
, A Z
CM
02/23/2018
SCALE: 1/8" = 1'-0"1 CODE FLOOR PLAN
ADA WOMEN'S RESTROOM SIGN 3/A2.5
ADA MEN'S RESTROOM SIGN 3/A2.5
WOMEN'S RESTROOM SIGN 4/A2.5
MEN'S RESTROOM SIGN 4/A2.5
SIGN TYPES
TYPE DESCRIPTION DETAIL
SCALE: 1/4" = 1'-0"2 SIGN MOUNTING HEIGHT/LOCATION
SCALE: 3" = 1'-0"3 ADA TOILET ROOM SIGN
SCALE: 3" = 1'-0"4 TOILET ROOM SIGN
A
B
C
D
1 ADDENDUM 2 05.15.18
| Sheets |
| G1.2 - CODE ANALYSIS & CODE REVIEW PLAN |
File details come from the government source that posted it.