About this file

These architectural drawings detail the rehabilitation of the South Park Ranger District Office located in Fairplay, Colorado, for the Pike and San Isabel National Forests and Cimarron and Comanche National Grasslands. The project scope includes comprehensive building improvements such as removing and installing a new standing seam metal roof with underlayment, ridge vent, flashing, gutters, and downspouts, along with an ice/snow melt system and associated electrical circuits. Interior modifications involve removing existing carpet and installing carpet tiles, replacing damaged acoustical ceiling panels, and sealing windows. An optional component includes installing a chain link fence with a personnel walk-through gate and a motorized gate with an operator and keypad, including related electrical work and safety features.

The detailed drawings (9 sheets) provide technical specifications for the renovation, covering site plan, floor plan, electrical and communication plans, roof details, fence and gate installation, and specific installation instructions. The project involves precise modifications to the existing ranger district office, with careful attention to preserving existing infrastructure while upgrading critical building systems. The electrical plans show modifications to the existing service entrance panel, adding new circuit breakers, communication outlets, and preparing for the optional gate installation. The comprehensive drawings indicate a thorough approach to rehabilitating the facility, ensuring functional improvements and maintaining the building's operational capabilities.

View the file

Other files for this federal contract opportunity

Other files attached to SOUTH PARK DISTRICT OFFICE REHAB, newest first.
File Type Posted
Updated Attach_3 Specifications_08.14.2025.pdf PDF
A0002.pdf PDF
Updated Attach _3 Specifications_07.30.2025.pdf PDF
A0001.pdf PDF
Attach 2_Schedule of Items_South Park.xlsx XLSX spreadsheet
Attach 4_Drawings_South Park.pdf PDF
1240LTR250039_South Park Rehab.pdf PDF
Attach 5_WD CO20250026_07.18.2025.pdf PDF
Attach 1 SOW_South Park.pdf PDF
Attach 3_Specifications_South Park.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATE

RECOMMENDED BY:

FOREST ENGINEER

PROJECT MANAGER

REGIONAL ENGINEER

FOREST SUPERVISOR

ENGINEERING/REGIONAL SPECIALIST [CDI MANAGER]

I HAVE REVIEWED THE TECHNICAL ASPECTS OF THESE DRAWINGS:

APPROVED BY:

THESE DRAWINGS COMPLY WITH THE FOREST PLAN AND PROJECT

SPECIFIC NEPA DOCUMENTATION:

DATE

DATE

DATE

DATE

PROJECT LOCATION

PROJECT ADDRESS

320 HIGHWAY 285

FAIRPLAY, CO 80440

LATITUDE: 39°13.312 N

LONGITUDE: 105°59.638 W

1. G1.0 TITLE SHEET AND INDEX

2. G1.1 ABBREVIATIONS

3. C1.1 SITE PLAN

4. C2.1 CHAIN LINK FENCE AND GATE DETAILS

5. A1.1 FLOOR PLAN

6. A1.2 REFLECTED CEILING PLAN

7. A1.3 ROOF PLAN AND PHOTOGRAPHS

8. A1.4 DETAILS

9. E1.1 ELECTRICAL AND COMMUNICATION PLAN,

PANELBOARD AND DETAILS

INDEX

SHEET SHEET

SUB

TITLE OF SHEET

PROJECT

LOCATION

1/

/2

:1

T

C M

IC

H

A E

L C

U

S E

R S

\T C

M

IC

H A

E L

\B O

X \C

D I\P

K S

I\B L

D G

S \F

A

IR

P

LA

Y \R

A N

G E

R O

F F

IC

E

\2

9_ R

E H

A B

\D W

G S

\T

-G

_A 1-

4_ E

1.

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

TITLE SHEET

AND

INDEX

CDI

PIKE AND SAN ISABEL NATIONAL

FORESTS CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER DISTRICT

PARK COUNTY, COLORADO

FAIRPLAY OFFICE

REHAB

PROJECT LOCATION

A

ABC AGGREGATE BASE COURSE

AB ANCHOR BOLT

A/C AIR CONDITIONING

AC ACOUSTICAL

ACT ACOUSTICAL TILE

ADR ACCESS DOOR

AD AREA DRAIN

ADD ADDENDUM

ADH ADHESIVE

ADJ ADJACENT

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AIP ABANDON IN PLACE

AL ALUMINUM

ALT ALTERNATE

ANOD ANODIZED

AP ACCESS PANEL

APPROX APPROXIMATE (LY)

ARCH ARCHITECT(URAL)

ASTM AMERICAN SOCIETY FOR TESTING

AND MATERIALS

AWG AMERICAN WIRE GAUGE

AUTO AUTOMATIC

B

BD BOARD

BATT INSULATION

BIT BITUMINOUS

BLDG BUILDING

BLK BLOCK(ING)

BM BEAM

BOL BEGINNING OF LINE

BOT BOTTOM

BR BACKER ROD

BS BOTH SIDES

BSMT BASEMENT

BW BOTH WAYS

C

CAB CABINET

CAL CALIBER

CB CATCH BASIN

CFM CUBIC FEET/MINUTE

CGR COILING GRILLE

CI CAST IRON

CIPC CAST-IN-PLACE CONCRETE

CJ CONTROL JOINT

CKT CRICKET

CL CENTERLINE

CLG CEILING

CLR CLEAR(ANCE)

CM CENTIMETER(S)

CMP CORRUGATED METAL PIPE

CMU CONCRETE MASONRY UNIT

CTR CENTER

CO CONTRACTING OFFICER

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS OR CONTINUE

COORD COORDINATE

COR CONTRACTING OFFICER REPRESENTATIVE

CP CONTROL POINT

CPT CARPET (ED)

CNTR COUNTER

CW COLD WATER

CWK CASEWORK

CX CONNECTION

CY CUBIC YARD

D

DBL DOUBLE

DEMO DEMOLISH, DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISP DISPOSAL

DN DOWN

DR DOOR

DS DOWNSPOUT

DSPR DISPENSER

DTL DETAIL

DWG DRAWING

DW DISHWASHER

SYMBOLS

ANGLE

@ AT

X BY

℄ CENTER LINE

CHANNEL

° DEGREES

Ø DIAMETER

ɸ ELECTRICAL PHASE

' FOOT

FLOWLINE

" INCH

d PENNY

PERPENDICULAR

PITCH, SLOPE

⅊ PROPERTY LINE, PLATE

# POUND

E

E EASTING

EA EACH

EB EXPANSION BOLT

EC ELECTRICAL COOKTOP

EG EXISTING GRADE

EJ EXPANSION JOINT

EL ELEVATION

ELL ELBOW

ELEV ELEVATION

ENC ENCLOSURE

ENT ENTRANCE

EOP EDGE OF PAVEMENT

EOR EDGE OF ROAD

EP ELECTRICAL PANEL

EOL END OF LINE

EQ EQUAL

EQP EQUIPMENT

ESR ELASTIC SHEET ROOFING

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPOSED

EXPN EXPANSION

EXT EXTERIOR

F

FAA FEDERAL AVIATION ADMINISTRATION

FACP FIRE ALARM CONTROL PANEL

FD FLOOR DRAIN

FEC FIRE EXTINGUISHER CABINET

FEX FIRE EXTINGUISHER

FFE FINISHED FLOOR ELEVATION

FG FINISHED GROUND

FH FIRE HYDRANT

FHS FIRE HOSE STATION

FIN FINISH(ED)

FL FLANGE

FLCO FLOOR CLEANOUT

FLG FLASHING

FLR(G) FLOOR(ING)

FND FOUNDATION

FOSF FACE OF STUD

FT FOOT, FEET

FTG FOOTING

G

GA GAUGE, GAGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACT (OR)

GF GOVERNMENT FURNISHED

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GL GLASS, GLAZING

GOVT GOVERNMENT

GR GRILLE

GRD GROUND

GS GALVANIZED STEEL

GSM GALVANIZED SHEET METAL

GUM GLASS UNIT MASONRY

GYPBD GYPSUM BOARD

H

H HIGH

HB HOSE BIBB

HC HOLLOW CORE

HDW HARDWARE

HDPE HIGH DENSITY POLYETHYLENE

HK HOOK(S)

HM HOLLOW METAL

HORZ HORIZONTAL

HP HIGH POINT

HR HOUR

HT HEIGHT

HTR HEATER

HVAC HEATING/VENTILATION/AIR

CONDITIONING

HW HOT WATER

HWH HOT WATER HEATER

HYD HYDRANT

I

ID INSIDE DIAMETER

IN INCH(ES)

INCL INCLUDE (D), (ING)

INFO INFORMATION

INS INSULATE (D), (ION)

INT INTERIOR

INV INVERT

IPS IRON PIPE SIZE

J

JAN JANITOR

JT JOINT

L

LAB LABORATORY

LAM LAMINATE (D)

LAV LAVATORY

LB POUND(S)

LF LINEAL, LINEAR FOOT

LIB LIBRARY

LIN LINEAL

LKR LOCKER

LL LIVE LOAD

M

MAINT MAINTAIN (ENANCE)

MAS MASONRY

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

MECH MECHANIC (AL)

MEDC MEDICINE CABINET

METL METAL

MFR MANUFACTURE (ER)

MH MANHOLE

MIN MINIMUM

MIR MIRROR

MISC MISCELLANEOUS

MMB MEMBRANE

MO MASONRY OPENING

MR MOISTURE RESISTANT

MT MOUNT (ED), (ING)

MUTCD MANUAL ON UNIFORM

TRAFFIC CONTROL DEVICES

N

N NORTHING

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NPT NATIONAL PIPE THREAD

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

O

O/ OVER

OA OVERALL

OBS OBSCURE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OPG OPENING

OPH OPPOSITE HAND

OPS OPERATIONS

ORD OVERFLOW ROOF DRAIN

OZ OUNCE

P

PAR PARALLEL

PED PEDESTRIAN

PL PLATE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PNT PAINT(ED)

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT POINT OF TANGENCY

PTN PARTITION

PTR PAPER TOWEL RECEPTOR

PVC POLYVINYL CHLORIDE

PVC POINT OF VERTICAL CURVE

PVI POINT OF VERTICAL INTERSECTION

PVT POINT OF VERTICAL TANGENT

PVMT PAVEMENT

PWD PLYWOOD

Q

QTY QUANTITY

R

R RESISTANCE, RISER

RAD RADIUS

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RE REFERENCE, REFER TO

RECP RECEPTACLE

REINF REINFORCING

REQ REQUIRE (D)

RINS RIGID INSULATION

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RP RADIANT PANEL

S

S SOUTH

SBLK SPLASH BLOCK

SC SOLID CORE

SCH SCHEDULE

SD STORM DRAIN

SEC SECTION

SF SQUARE FEET

SGT STRUCTURAL GLAZED TILE

SH SHELF, SHELVING

SHT SHEET

SHTHG SHEATHING

SIM SIMILIAR

SIP STRUCTURAL INSULATED PANEL

SND SANITARY NAPKIN DISPENSER

SNR SANITARY NAPKIN RECEPTOR

SOG SLAB ON GRADE

SPC SPACER/SHIM

SPEC SPECIFICATION (S)

SQ SQUARE

SSK SERVICE SINK

SS STAINLESS STEEL

STA STATION

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STO STORAGE

STRUC STRUCTURAL

SUSP SUSPENDED

SWBD SWITCHBOARD

SYM SYMMETRICAL

T

T TREAD

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TB TEST BORING/TOWEL BAR

TEL TELEPHONE

TEMP TEMPERATURE

THK THICK (NESS)

THR THRESHOLD

THRU THROUGH

TO TOP OF

TOB TOP OF BEAM

TOC TOP OF CURB

TOP TOP OF PARAPET

TOS TOP OF SLAB

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPTN TOILET PARTITION

TR TRANSOM

TRANSL TRANSLUCENT

TS TUBE STEEL

TV TELEVISION

TWB TREATED WOOD BLOCKING

TX TRANSFORMER

TYP TYPICAL

TZ TERRAZZO

U

UC UNDERCUT

UL UNDERWRITERS LABORATORY

UNFIN UNFINISHED

UON UNLESS OTHERWISE NOTED

UR URINAL

V

VAR VARIABLE (VARIES)

VB VAPOR BARRIER

VC VERTICAL CURVE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

W

W WIDE OR WIDTH

W WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WALL HYDRANT

WP (G) WATER`PROOF (ING)

WPT WORK POINT

WR WATER RESISTANT

WWF WELDED WIRE FABRIC

X

XFMR TRANSFORMER CONTROL DEVICE

T

C M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S T

G

A

E

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

ABBREVIATIONS

CDI

D.LIRA/L.CARROLL

G1.1

O

E

O

E

U

E

T

U

E

T

U

E

T

U

E

T

U

E

T

U

E

T

U

E

T

G

W

W

W

W

W

W

W

W W

W W

W

W

W

S

S

S

S

PNL SEP

SEP1,3

M

SIDEWALK

S

I

D

E

W

A

L

K

S

I

D

E

W

A

L

K

DISTRICT OFFICE

U

E

U

E

U

E

U

E

U

E

U

E

U

E

U

E

U

E

M

GRAVEL

U

E

U

E

SEP6,8

SEP10

GRAVEL

PARKING

ASPHALT

PARKING

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S U

S

I T

E D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

SITE PLAN

T.MICHAEL

D.LIRA/L.CARROL

C1.1

SITE PLAN

KEY NOTES

EXISTING 200 AMP SERVICE ENTRANCE PANEL (SEP). INSTALL 15A-2P AND

15A-1P CIRCUIT BREAKERS FOR MOTORIZED GATE. SEE PANELBOARD

SCHEDULE ON E1.1.

INSTALL 6'-0" HIGH CHAIN LINK FENCE.

INSTALL 4'-0" X 6'-0" WALK THRU GATE WITH MECHANICAL LOCK.

INSTALL 16'-0" X 6'-0" MOTORIZED VEHICLE SWING GATE.

MOUNT GATE OPERATOR ON NOMINAL 4" THICK CONCRETE PAD 6" LARGER

THAN GATE OPERATOR. INSTALL 3-#10 AND #10 GROUND FOR GATE

OPERATOR AND 2-#10 AND #10 GROUND FOR HEATER IN 1" PVC SCHEDULE 80

CONDUIT. ROUTE POWER TO EXISTING SPARE CONDUITS. INSTALL THREE

LOOP DETECTORS, GEARBOX HEATER, KNOX BOX AND PHOTOEYE.

REVERSE LOOP, APPROXIMATELY 12'-0" BY 6'-0".

SHADOW LOOP, APPROXIMATELY 10'-0" X 12'-0"

REVERSE/EXIT LOOP, APPROXIMATELY 12'-0" BY 6'-0".

GOOSENECK WITH CARD READER/KEY PAD. MOUNT ON 12" X12"X 48"

CONCRETE PIER. ROUTE LOW VOLTAGE CONTROL CONDUCTORS IN 3/4"

CONDUIT TO GATE OPERATOR.

TWO EXISTING SPARE 1" CONDUITS. EXTEND ONE TO MOTORIZED GATE

OPERATOR AND INSTALL POWER CIRCUIT IN CONDUIT.

EXISTING UTILITY TO REMAIN, TYPICAL.

GENERAL NOTES

1. FIELD VERIFY EXISTING SITE CONDITIONS

AND LOCATE EXISTING UTILITIES PRIOR

TO CONSTRUCTION.

2. CALL 811 BEFORE YOU DIG. LOCATE BOTH

UTILITY OWNED AND GOVERNMENT

OWNED UTILITIES ON THE PROPERTY.

3. SEE FENCE AND GATE DETAILS ON C2.1.

4. SEE TRENCH DETAIL ON E1.1.

10 0 10 20

SCALE OF FEET

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text J

AutoCAD SHX Text P

AutoCAD SHX Text

GFI WP

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text J

CORNER

POST

LINE

POST

LINE

POST

END

POST

TOP RAIL

ROLL-FORMED

RAIL SPLICE

RAIL END

12"Ø CONCRETE

FOOTERS, TYP.

TENSION BAND AND

STRETCHER BAR

FERRULE, TYP.

TRUSS ROD

HOG RINGS,

TYP.

11 GA. WIRE

FASTENERS

TENSION WIRE

BRACE AND

TRUSS BAND

TENSION

BAND

ALL POSTS 3" CLEAR FROM

BOTTOM OF FOOTER, TYP.

10'-0" MAX

ALL POST SPACING

M

A X

FINISH GRADE

M

A X

T Y

P

A B

O V

E

T O

P

R

A I L

10'-0" MAX.

TRUSS ROD

BRACE RAIL

M

A X

F O

R

A

C C

E S

S I B

I L

I T

Y

4'-0"

3'-4"

A B

O V

E

F

G

12"Ø CONCRETE

FOOTERS, TYP.

TOP RAIL

FOR FENCE

LINE

POST

LINE

POST

FINISH

GRADE

PEDESTRIAN

GATE

MECHANICAL

KEYPAD LOCK

TENSION

WIRE

2" CHAIN LINK FENCE

FABRIC, TYP.

TRUSS ROD

TURNBUCKLE, TYP.

M

A X

F O

R

A

C C

E S

S I B

I L

I T

Y

16'-0"

15-6"

A B

O V

E

F

G

12"Ø CONCRETE

FOOTERS, TYP.

TOP RAIL

FOR FENCE

LINE

POST

4" HINGE

POST

FINISH

GRADE

VEHICLE

GATE

MECHANICAL

KEYPAD LOCK

TENSION

WIRE

5'-2" 5'-2" 5'-2"

T Y

P

11 GA. WIRE

FASTENERS,

TYP.

TIGHTENER OR TURNBUCKLE

SYMBOL,

ATTACH FABRIC TO ALL FENCE &

GATE STRUCTURES AT 12"

INTERVALS VERTICALLY & AT 20"

HORIZONTALLY.

TRUSS ROD, TYP.

TRUSS ROD

TURNBUCKLE, TYP.

BRACE RAIL

GATE RAIL,

TYP.

TENSION BAND

AND STRETCHER

BAR, TYP.

18"Ø CONCRETE

FOOTER

T Y

P

T Y

P

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S C

X X

C

H A

I N

L I N

K F

E N

C E

D

E T

S D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

CHAIN LINK FENCE

AND GATE

DETAILS

J.KEHM

D.LIRA/L.CARROLL

C2.1

SWING GATE DETAIL

NO SCALE PEDESTRIAN GATE DETAIL

NO SCALE

FENCE INSTALLATION DETAILS

NO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%ULEGEND

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

OFFICE

OFFICE

OFFICE

COMPUTER RM

VISITOR INFO

RECEP

UTILITY

CONF.

MECH

STORAGE

STORAGE

VESTIBULE

OFFICE II

OFFICEI

OFFICE III

WOMEN

MEN

HALL

BATHROOM

BATHROOM

HALLWAY

FOYER

MECH

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S T

G

A

E

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

FLOOR PLAN

CDI

D.LIRA/L.CARROLL

A1.1

4 0 4 128

SCALE OF FEET

3/16" = 1'-0"

FLOOR PLAN

KEY NOTES

REMOVE TRIM AND SIDING ABOVE, BELOW, AND SIDES OF WINDOW.

SEAL ALL WINDOW EDGES WEATHER TIGHT. INSTALL NEW SIDING

AND TRIM.

REMOVE CARPET. INSTALL CARPET SQUARES TO MATCH EXISTING

CARPET SQUARES. TYPICAL ALL ROOMS WITH CARPET.

EXISTING CARPET SQUARES TO REMAIN, TYPICAL.

EXISTING VINYL FLOORING TO REMAIN, TYPICAL.

EXISTING CONCRETE FLOOR TO REMAIN, TYPICAL.

GENERAL NOTES

1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO

CONSTRUCTION. NOTIFY CONTRACTING

OFFICER OF ANY DISCREPANCIES AFFECTING

WORK.

2. CONTRACTOR SHALL MOVE FURNITURE AS

NECESSARY FOR CARPET REPLACEMENT.

3. SEAL AROUND WINDOWS UTILIZING LOW

EXPANSION POLYURETHANE FOAM DESIGNED

TO AIR SEAL WITHOUT EXERTING PRESSURE

TO WINDOWS. COMPLY WITH AAMA 812-04

ASTM E84/UL 723, CLASS A FIRE RATED, UL

CLASSIFIED. R-VALUE OF 4.

PH1

A1.1

WINDOW AND SIDING

PH2

A1.1

PH1

A1.1

PH2

A1.1

WINDOW AND SIDING CLOSE UP

PH3

A1.1

CARPET AND CARPET TILE

PH3

A1.1

PhillipKrieble Polygon

OFFICE

OFFICE

OFFICE

COMPUTER RM

VISITOR INFO

RECEP

UTILITY

CONF.

MECH

STORAGE

STORAGE

VESTIBULE

OFFICE II

OFFICEI

OFFICE III

WOMEN

MEN

HALL

BATHROOM

BATHROOM

HALLWAY

FOYER

MECH

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S T

G

A

E

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

REFLECTED CEILING

PLAN

CDI

D.LIRA/L.CARROLL

A1.2

4 0 4 128

SCALE OF FEET

3/16" = 1'-0"

REFLECTED CEILING PLAN

KEY NOTES

REMOVE AND REPLACE 24" X 48" CEILING PANELS. MATCH EXISTING

TILES.

REMOVE AND REPLACE 30 DAMAGED 12" X 12" CEILING TILES. MATCH

EXISTING TILES. FIELD LOCATE DAMAGED TILES.

EXISTING 24" X 48" CEILING PANELS TO REMAIN.

GENERAL NOTES

1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO

CONSTRUCTION. NOTIFY CONTRACTING

OFFICER OF ANY DISCREPANCIES AFFECTING

WORK.

2. TEST SAMPLING OF 12"X12" CEILING TILES AND

MASTIC FOR ASBESTOS CONTAINING MATERIAL

(ACM) PRIOR TO REMOVING. PROVIDE

CONTRACTING OFFICER WITH TEST RESULTS.

3. CONTRACTING OFFICER WILL PROVIDE

METHODS AND REQUIREMENTS IF ACM TEST

PROVES POSITIVE. COST FOR THESE

METHODS AND REQUIREMENTS ARE NOT

INCLUDED IN THIS CONTRACT.

PH2

A1.2

12" X 12" CEILING TILES

PH1

A1.2

PH2

A1.2

PH1

A1.2

2 X 4 CEILING PANELS

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S T

G

A

E

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

ROOF PLAN AND

PHOTOGRAPHS

CDI

D.LIRA/L.CARROLL

A1.3

4 0 4 128

SCALE OF FEET

3/16" = 1'-0"

ROOF PLAN

KEY NOTES

REMOVE STANDING SEAM METAL ROOF, UNDERLAYMENT, DRIP EDGE, ROOF

MOUNTED JACKS, AND ASSOCIATED EQUIPMENT. REMOVE GUTTERS AND

DOWNSPOUTS. INSTALL NEW STANDING SEAM METAL ROOF, UNDERLAYMENT,

DRIP EDGE, ROOF MOUNTED JACKS, AND ASSOCIATED EQUIPMENT. INSTALL

NEW GUTTERS AND DOWNSPOUTS. FLASH AND COUNTER FLASH ROOF

PENETRATIONS. NOT ALL ROOF PENETRATIONS SHOWN.

REMOVE AND INSTALL NEW RIDGE VENT.

INSTALL ELECTRIC HEAT PANEL. SEE DETAIL ON A1.4. TYPICAL.

INSTALL VALLEY HEAT PANEL, TYPICAL.

INSTALL NEW GUTTER AND HEAT TAPE IN GUTTER.

INSTALL DOWNSPOUT AND HEAT TAPE IN DOWNSPOUT.

REMOVE TWO 10"Ø DUCTS FROM ROOF. INSTALL CUSTOM BUILT ROOF CURB

WITH CRICKET AND TWO 10"Ø GOOSENECKS. CONNECT DUCTS TO

GOOSENECKS AND SEAL. FLASH AND COUNTER FLASH ROOF CURB.

EXISTING ROOF CURB. FLASH AND COUNTER FLASH CURB.

GENERAL NOTES

1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.

2. EXISTING ROOF IS METAL WITH RIBS APPROXIMATELY 24" ON

CENTER.

3. COORDINATE HEAT PANEL AND HEAT TAPE REQUIREMENTS WITH

ELECTRICAL ON E1.1.

PH4

A1.3

PH1

A1.3

PH2

A1.3

PH3

A1.3

PH5

A1.3

PH1

A1.3

GUTTER AND ROOF

PH2

A1.3

GUTTER AND ROOF

PH5

A1.3

ROOF MOUNT DUCTS

PH4

A1.3

GUTTER AND ROOF

PH3

A1.3

GUTTER AND ROOF

HEAT PANEL

FASTNER

EAVE STARTER FLASHING

"x

" DOUBLE BEAD BUTYL TAPE

FASTNER

UNDERLAYMENT

PREFINISHED GUTTER STRAP

GUTTER

SUBSTRATE

SUBSTRATE

STANDING SEAM, PANEL

AND SNAP-ON BATTEN

INSTALL HEAT TAPE

IN CHANNEL, TYPICAL

HEAT TAPE IN GUTTER

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S T

G

A

E

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

DETAILS

CDI

D.LIRA/L.CARROLL

A1.4

ELECTRIC HEAT PANEL DETAIL

NO SCALE

GENERAL NOTES

1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO

CONSTRUCTION. NOTIFY CONTRACTING

OFFICER OF ANY DISCREPANCIES AFFECTING

WORK.

2. COORDINATE ROOF INSTALLATION WITH HEAT

PANEL INSTALLATION.

3. COORDINATE HEAT PANEL POWER

REQUIREMENTS WITH ELECTRICAL

INSTALLATION.

OFFICE

OFFICE

OFFICE

COMPUTER RM

VISITOR INFO

RECEP

UTILITY

CONF.

MECH

STORAGE

STORAGE

VESTIBULE

OFFICE II

OFFICEI

OFFICE III

WOMEN

MEN

HALL

BATHROOM

BATHROOM

HALLWAY

FOYER

MECH

C

PNL A

J

J

J

PNL B

PNL C

PNL SEP

O

C

O

BUS AMPS 200

MAIN CB AMPS 200

MAIN CIRCUIT BREAKER (CB)

VOLTS: 120/240 - 1 PHASE, 3 WIRE

SUBTOTAL

A

VA LOAD PER LEG

B

10,000 A.I.R.

LOAD CBDESCRIPTION &

A

MIN. WIRE SIZES TYPE AMP NO.POLE

EXISTING SERVICE ENTRANCE PANEL "SEP"

TOTAL A: 17,760 VA, 148 AMP

TOTAL B: 17,760 VA, 148 AMP

8160 8160 9600

B

MIN. WIRE SIZESAMPNO. POLE TYPE

CB LOAD DESCRIPTION &

TOTAL CONNECTED VA: 35,520

TOTAL CONNECTED AMPS: 148

TOTAL DEMAND VA: 42,240

TOTAL DEMAND AMPS: 176

ENGINE BLOCK HEATER

= GFEP CIRCUIT BREAKER (30 ma)

5 = MISCELLANEOUS

6 = SPARE

7 = SPACE

4 = KITCHEN

1 = LIGHTS

2 = RECEPTACLES

3 = MOTORS

LOAD TYPES:

MOTORS

KITCHEN

MISCELLANEOUS

LARGEST MOTOR

LIGHTS

RECEPTACLES

RECEPTACLES

26,880

8,640

CONNECTED

VA

33,600

8,640

DEMAND

VA

31002

EXISTING ELECTRICAL

OUTLETS

40 2

HEAT TAPE CONTROLLER

13 14

17 18

35,520 42,240

30 2

SURGE PROTECTION

DEVICE

(FUTURE

PANEL

SURFACE MOUNT, 3R

GATE OPERATOR

GATE OPERATOR HEATER

V A

R I E

S t o

D

D

*** 2'-0" MIN. COVER OVER ELECTRICAL

UTILITY LINE DEPTHS

6" MINIMUM BEDDING

INITIAL BACKFILL

DETECTABLE WARNING TAPE

SUBSEQUENT BACKFILL

D + 1'-0"

WIDEN TRENCH

AS NEEDED

ABOVE PIPE FOR

WORKER SAFETY

CONDUIT

GRADE

TRENCH DETAIL

NOT TO SCALE

3" GRAVEL OVER COMPACTED

BACKFILL

M

I C

H A

E L

C

U

S E

R S

T

C M

I C

H A

E L B

O X

C

D I P

K S

I B

L D

G S

F

A I R

P L A

Y R

A N

G E

R

O

F F

I C

E R

E H

A B

D

W G

S T

G

A

E

D

W G

SHEET

OF

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

SUB SHEET NO.

DATENO.

REVISION / ISSUE

FAIRPLAY OFFICE

REHAB

PIKE AND SAN ISABEL

NATIONAL FORESTS

CIMARRON AND

COMANCHE NATIONAL

GRASSLANDS

SOUTH PARK RANGER

DISTRICT

02/2020 9

R2

ROCKY MOUNTAIN

REGION

F

O

R

E

S T

SE

R

V

I

C

E

D E

P

A

R

T M

E N

T

OF AGR

I C

U

L

T

U R

E

DATE

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

ELECTRICAL AND

COMMUNICATION

PLAN, PANELBOARD

AND DETAILS

CDI

D.LIRA/L.CARROLL

E1.1

4 0 4 128

SCALE OF FEET

3/16" = 1'-0"

ELECTRICAL AND COMMUNICATION PLAN

KEY NOTES

INSTALL NEW SURFACE MOUNTED JUNCTION BOX WITH DATA JACK

AND COVER PLATE. ROUTE CABLE IN SURFACE MOUNTED CONDUIT

TO TELECOM ROOM. TYPICAL.

INSTALL NEW SINGLE GANG, TWIST LOCK, L5/20R RECEPTACLE.

ROUTE CONDUCTORS IN SURFACE MOUNTED CONDUIT TO NEW

20A-1P CIRCUIT BREAKER IN PANEL C.

INSTALL 20A-1P AND 30A-2P 30mA GFEP CIRCUIT BREAKERS IN PANEL.

INSTALL 30A-2P 30mA GFEP CIRCUIT BREAKER IN PANEL.

ROUTE 2-#10 WITH #10 GROUND IN 3/4" CONDUIT FROM CONTROLLER

TO 30A-2P 30mA GFEP CIRCUIT BREAKER IN PANEL B AND TO SNOW

MELT JUNCTION BOXES. COORDINATE CONTROLLER LOCATION WITH

SNOW/ICE MELT SYSTEM ON A1.3.

INSTALL OUTLET BOX FOR SNOW SENSOR CONTROL/DISPLAY PANEL.

MOUNT CENTER OF BOX 48" ABOVE FINISHED FLOOR. ROUTE 22-5

CONDUCTOR CABLE IN 1/2" CONDUIT TO CONTROLLER.

INSTALL JUNCTION BOX BELOW EAVE FOR CONNECTION TO SNOW

MELT CABLES. COORDINATE JUNCTION BOX LOCATION WITH SNOW

MELT PANEL INSTALLATION. TYPICAL.

EXISTING ELECTRICAL PANEL TO REMAIN, TYPICAL.

EXISTING MAIN SERVICE PANEL. INSTALL 15A-2P AND 15A-1P CIRCUIT

BREAKER.

GENERAL NOTES

1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO

CONSTRUCTION.

2. COORDINATE SNOW/ICE MELT ELECTRICAL

REQUIREMENTS AND LAYOUT WITH A1.3 AND

INSTALLATION.

3. SEE C1.1 FOR SITE ELECTRICAL WORK.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

G10
Sheets and Views
G10
G11
Sheets and Views
G11
C11
Sheets and Views
C11
C21
Sheets and Views
C21
A11
Sheets and Views
A11
A12
Sheets and Views
A12
A13
Sheets and Views
A13
A14
Sheets and Views
A14
E11
Sheets and Views
E11

File details come from the government source that posted it. Updated .