About this file
These architectural drawings detail the rehabilitation of the South Park Ranger District Office located in Fairplay, Colorado, for the Pike and San Isabel National Forests and Cimarron and Comanche National Grasslands. The project scope includes comprehensive building improvements such as removing and installing a new standing seam metal roof with underlayment, ridge vent, flashing, gutters, and downspouts, along with an ice/snow melt system and associated electrical circuits. Interior modifications involve removing existing carpet and installing carpet tiles, replacing damaged acoustical ceiling panels, and sealing windows. An optional component includes installing a chain link fence with a personnel walk-through gate and a motorized gate with an operator and keypad, including related electrical work and safety features.
The detailed drawings (9 sheets) provide technical specifications for the renovation, covering site plan, floor plan, electrical and communication plans, roof details, fence and gate installation, and specific installation instructions. The project involves precise modifications to the existing ranger district office, with careful attention to preserving existing infrastructure while upgrading critical building systems. The electrical plans show modifications to the existing service entrance panel, adding new circuit breakers, communication outlets, and preparing for the optional gate installation. The comprehensive drawings indicate a thorough approach to rehabilitating the facility, ensuring functional improvements and maintaining the building's operational capabilities.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Updated Attach_3 Specifications_08.14.2025.pdf | ||
| A0002.pdf | ||
| Updated Attach _3 Specifications_07.30.2025.pdf | ||
| A0001.pdf | ||
| Attach 2_Schedule of Items_South Park.xlsx | XLSX spreadsheet | |
| Attach 4_Drawings_South Park.pdf | ||
| 1240LTR250039_South Park Rehab.pdf | ||
| Attach 5_WD CO20250026_07.18.2025.pdf | ||
| Attach 1 SOW_South Park.pdf | ||
| Attach 3_Specifications_South Park.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE
RECOMMENDED BY:
FOREST ENGINEER
PROJECT MANAGER
REGIONAL ENGINEER
FOREST SUPERVISOR
ENGINEERING/REGIONAL SPECIALIST [CDI MANAGER]
I HAVE REVIEWED THE TECHNICAL ASPECTS OF THESE DRAWINGS:
APPROVED BY:
THESE DRAWINGS COMPLY WITH THE FOREST PLAN AND PROJECT
SPECIFIC NEPA DOCUMENTATION:
DATE
DATE
DATE
DATE
PROJECT LOCATION
PROJECT ADDRESS
320 HIGHWAY 285
FAIRPLAY, CO 80440
LATITUDE: 39°13.312 N
LONGITUDE: 105°59.638 W
1. G1.0 TITLE SHEET AND INDEX
2. G1.1 ABBREVIATIONS
3. C1.1 SITE PLAN
4. C2.1 CHAIN LINK FENCE AND GATE DETAILS
5. A1.1 FLOOR PLAN
6. A1.2 REFLECTED CEILING PLAN
7. A1.3 ROOF PLAN AND PHOTOGRAPHS
8. A1.4 DETAILS
9. E1.1 ELECTRICAL AND COMMUNICATION PLAN,
PANELBOARD AND DETAILS
INDEX
SHEET SHEET
SUB
TITLE OF SHEET
PROJECT
LOCATION
1/
/2
:1
T
C M
IC
H
A E
L C
U
S E
R S
\T C
M
IC
H A
E L
\B O
X \C
D I\P
K S
I\B L
D G
S \F
A
IR
P
LA
Y \R
A N
G E
R O
F F
IC
E
\2
9_ R
E H
A B
\D W
G S
\T
-G
_A 1-
4_ E
1.
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
TITLE SHEET
AND
INDEX
CDI
PIKE AND SAN ISABEL NATIONAL
FORESTS CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER DISTRICT
PARK COUNTY, COLORADO
FAIRPLAY OFFICE
REHAB
PROJECT LOCATION
A
ABC AGGREGATE BASE COURSE
AB ANCHOR BOLT
A/C AIR CONDITIONING
AC ACOUSTICAL
ACT ACOUSTICAL TILE
ADR ACCESS DOOR
AD AREA DRAIN
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AIP ABANDON IN PLACE
AL ALUMINUM
ALT ALTERNATE
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE (LY)
ARCH ARCHITECT(URAL)
ASTM AMERICAN SOCIETY FOR TESTING
AND MATERIALS
AWG AMERICAN WIRE GAUGE
AUTO AUTOMATIC
B
BD BOARD
BATT INSULATION
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK(ING)
BM BEAM
BOL BEGINNING OF LINE
BOT BOTTOM
BR BACKER ROD
BS BOTH SIDES
BSMT BASEMENT
BW BOTH WAYS
C
CAB CABINET
CAL CALIBER
CB CATCH BASIN
CFM CUBIC FEET/MINUTE
CGR COILING GRILLE
CI CAST IRON
CIPC CAST-IN-PLACE CONCRETE
CJ CONTROL JOINT
CKT CRICKET
CL CENTERLINE
CLG CEILING
CLR CLEAR(ANCE)
CM CENTIMETER(S)
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CTR CENTER
CO CONTRACTING OFFICER
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS OR CONTINUE
COORD COORDINATE
COR CONTRACTING OFFICER REPRESENTATIVE
CP CONTROL POINT
CPT CARPET (ED)
CNTR COUNTER
CW COLD WATER
CWK CASEWORK
CX CONNECTION
CY CUBIC YARD
D
DBL DOUBLE
DEMO DEMOLISH, DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISP DISPOSAL
DN DOWN
DR DOOR
DS DOWNSPOUT
DSPR DISPENSER
DTL DETAIL
DWG DRAWING
DW DISHWASHER
SYMBOLS
ANGLE
@ AT
X BY
℄ CENTER LINE
CHANNEL
° DEGREES
Ø DIAMETER
ɸ ELECTRICAL PHASE
' FOOT
FLOWLINE
" INCH
d PENNY
PERPENDICULAR
PITCH, SLOPE
⅊ PROPERTY LINE, PLATE
# POUND
E
E EASTING
EA EACH
EB EXPANSION BOLT
EC ELECTRICAL COOKTOP
EG EXISTING GRADE
EJ EXPANSION JOINT
EL ELEVATION
ELL ELBOW
ELEV ELEVATION
ENC ENCLOSURE
ENT ENTRANCE
EOP EDGE OF PAVEMENT
EOR EDGE OF ROAD
EP ELECTRICAL PANEL
EOL END OF LINE
EQ EQUAL
EQP EQUIPMENT
ESR ELASTIC SHEET ROOFING
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXPN EXPANSION
EXT EXTERIOR
F
FAA FEDERAL AVIATION ADMINISTRATION
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FEX FIRE EXTINGUISHER
FFE FINISHED FLOOR ELEVATION
FG FINISHED GROUND
FH FIRE HYDRANT
FHS FIRE HOSE STATION
FIN FINISH(ED)
FL FLANGE
FLCO FLOOR CLEANOUT
FLG FLASHING
FLR(G) FLOOR(ING)
FND FOUNDATION
FOSF FACE OF STUD
FT FOOT, FEET
FTG FOOTING
G
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACT (OR)
GF GOVERNMENT FURNISHED
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GL GLASS, GLAZING
GOVT GOVERNMENT
GR GRILLE
GRD GROUND
GS GALVANIZED STEEL
GSM GALVANIZED SHEET METAL
GUM GLASS UNIT MASONRY
GYPBD GYPSUM BOARD
H
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HDW HARDWARE
HDPE HIGH DENSITY POLYETHYLENE
HK HOOK(S)
HM HOLLOW METAL
HORZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HTR HEATER
HVAC HEATING/VENTILATION/AIR
CONDITIONING
HW HOT WATER
HWH HOT WATER HEATER
HYD HYDRANT
I
ID INSIDE DIAMETER
IN INCH(ES)
INCL INCLUDE (D), (ING)
INFO INFORMATION
INS INSULATE (D), (ION)
INT INTERIOR
INV INVERT
IPS IRON PIPE SIZE
J
JAN JANITOR
JT JOINT
L
LAB LABORATORY
LAM LAMINATE (D)
LAV LAVATORY
LB POUND(S)
LF LINEAL, LINEAR FOOT
LIB LIBRARY
LIN LINEAL
LKR LOCKER
LL LIVE LOAD
M
MAINT MAINTAIN (ENANCE)
MAS MASONRY
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MECH MECHANIC (AL)
MEDC MEDICINE CABINET
METL METAL
MFR MANUFACTURE (ER)
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MMB MEMBRANE
MO MASONRY OPENING
MR MOISTURE RESISTANT
MT MOUNT (ED), (ING)
MUTCD MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES
N
N NORTHING
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPT NATIONAL PIPE THREAD
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O
O/ OVER
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPG OPENING
OPH OPPOSITE HAND
OPS OPERATIONS
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
P
PAR PARALLEL
PED PEDESTRIAN
PL PLATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNT PAINT(ED)
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENCY
PTN PARTITION
PTR PAPER TOWEL RECEPTOR
PVC POLYVINYL CHLORIDE
PVC POINT OF VERTICAL CURVE
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENT
PVMT PAVEMENT
PWD PLYWOOD
Q
QTY QUANTITY
R
R RESISTANCE, RISER
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFERENCE, REFER TO
RECP RECEPTACLE
REINF REINFORCING
REQ REQUIRE (D)
RINS RIGID INSULATION
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RP RADIANT PANEL
S
S SOUTH
SBLK SPLASH BLOCK
SC SOLID CORE
SCH SCHEDULE
SD STORM DRAIN
SEC SECTION
SF SQUARE FEET
SGT STRUCTURAL GLAZED TILE
SH SHELF, SHELVING
SHT SHEET
SHTHG SHEATHING
SIM SIMILIAR
SIP STRUCTURAL INSULATED PANEL
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTOR
SOG SLAB ON GRADE
SPC SPACER/SHIM
SPEC SPECIFICATION (S)
SQ SQUARE
SSK SERVICE SINK
SS STAINLESS STEEL
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STO STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SWBD SWITCHBOARD
SYM SYMMETRICAL
T
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TEST BORING/TOWEL BAR
TEL TELEPHONE
TEMP TEMPERATURE
THK THICK (NESS)
THR THRESHOLD
THRU THROUGH
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CURB
TOP TOP OF PARAPET
TOS TOP OF SLAB
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TR TRANSOM
TRANSL TRANSLUCENT
TS TUBE STEEL
TV TELEVISION
TWB TREATED WOOD BLOCKING
TX TRANSFORMER
TYP TYPICAL
TZ TERRAZZO
U
UC UNDERCUT
UL UNDERWRITERS LABORATORY
UNFIN UNFINISHED
UON UNLESS OTHERWISE NOTED
UR URINAL
V
VAR VARIABLE (VARIES)
VB VAPOR BARRIER
VC VERTICAL CURVE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
W
W WIDE OR WIDTH
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WALL HYDRANT
WP (G) WATER`PROOF (ING)
WPT WORK POINT
WR WATER RESISTANT
WWF WELDED WIRE FABRIC
X
XFMR TRANSFORMER CONTROL DEVICE
T
C M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S T
G
A
E
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
ABBREVIATIONS
CDI
D.LIRA/L.CARROLL
G1.1
O
E
O
E
U
E
T
U
E
T
U
E
T
U
E
T
U
E
T
U
E
T
U
E
T
G
W
W
W
W
W
W
W
W W
W W
W
W
W
S
S
S
S
PNL SEP
SEP1,3
M
SIDEWALK
S
I
D
E
W
A
L
K
S
I
D
E
W
A
L
K
DISTRICT OFFICE
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
M
GRAVEL
U
E
U
E
SEP6,8
SEP10
GRAVEL
PARKING
ASPHALT
PARKING
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S U
S
I T
E D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
SITE PLAN
T.MICHAEL
D.LIRA/L.CARROL
C1.1
SITE PLAN
KEY NOTES
EXISTING 200 AMP SERVICE ENTRANCE PANEL (SEP). INSTALL 15A-2P AND
15A-1P CIRCUIT BREAKERS FOR MOTORIZED GATE. SEE PANELBOARD
SCHEDULE ON E1.1.
INSTALL 6'-0" HIGH CHAIN LINK FENCE.
INSTALL 4'-0" X 6'-0" WALK THRU GATE WITH MECHANICAL LOCK.
INSTALL 16'-0" X 6'-0" MOTORIZED VEHICLE SWING GATE.
MOUNT GATE OPERATOR ON NOMINAL 4" THICK CONCRETE PAD 6" LARGER
THAN GATE OPERATOR. INSTALL 3-#10 AND #10 GROUND FOR GATE
OPERATOR AND 2-#10 AND #10 GROUND FOR HEATER IN 1" PVC SCHEDULE 80
CONDUIT. ROUTE POWER TO EXISTING SPARE CONDUITS. INSTALL THREE
LOOP DETECTORS, GEARBOX HEATER, KNOX BOX AND PHOTOEYE.
REVERSE LOOP, APPROXIMATELY 12'-0" BY 6'-0".
SHADOW LOOP, APPROXIMATELY 10'-0" X 12'-0"
REVERSE/EXIT LOOP, APPROXIMATELY 12'-0" BY 6'-0".
GOOSENECK WITH CARD READER/KEY PAD. MOUNT ON 12" X12"X 48"
CONCRETE PIER. ROUTE LOW VOLTAGE CONTROL CONDUCTORS IN 3/4"
CONDUIT TO GATE OPERATOR.
TWO EXISTING SPARE 1" CONDUITS. EXTEND ONE TO MOTORIZED GATE
OPERATOR AND INSTALL POWER CIRCUIT IN CONDUIT.
EXISTING UTILITY TO REMAIN, TYPICAL.
GENERAL NOTES
1. FIELD VERIFY EXISTING SITE CONDITIONS
AND LOCATE EXISTING UTILITIES PRIOR
TO CONSTRUCTION.
2. CALL 811 BEFORE YOU DIG. LOCATE BOTH
UTILITY OWNED AND GOVERNMENT
OWNED UTILITIES ON THE PROPERTY.
3. SEE FENCE AND GATE DETAILS ON C2.1.
4. SEE TRENCH DETAIL ON E1.1.
10 0 10 20
SCALE OF FEET
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text
GFI WP
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text J
CORNER
POST
LINE
POST
LINE
POST
END
POST
TOP RAIL
ROLL-FORMED
RAIL SPLICE
RAIL END
12"Ø CONCRETE
FOOTERS, TYP.
TENSION BAND AND
STRETCHER BAR
FERRULE, TYP.
TRUSS ROD
HOG RINGS,
TYP.
11 GA. WIRE
FASTENERS
TENSION WIRE
BRACE AND
TRUSS BAND
TENSION
BAND
ALL POSTS 3" CLEAR FROM
BOTTOM OF FOOTER, TYP.
10'-0" MAX
ALL POST SPACING
M
A X
FINISH GRADE
M
A X
T Y
P
A B
O V
E
T O
P
R
A I L
10'-0" MAX.
TRUSS ROD
BRACE RAIL
M
A X
F O
R
A
C C
E S
S I B
I L
I T
Y
4'-0"
3'-4"
A B
O V
E
F
G
12"Ø CONCRETE
FOOTERS, TYP.
TOP RAIL
FOR FENCE
LINE
POST
LINE
POST
FINISH
GRADE
PEDESTRIAN
GATE
MECHANICAL
KEYPAD LOCK
TENSION
WIRE
2" CHAIN LINK FENCE
FABRIC, TYP.
TRUSS ROD
TURNBUCKLE, TYP.
M
A X
F O
R
A
C C
E S
S I B
I L
I T
Y
16'-0"
15-6"
A B
O V
E
F
G
12"Ø CONCRETE
FOOTERS, TYP.
TOP RAIL
FOR FENCE
LINE
POST
4" HINGE
POST
FINISH
GRADE
VEHICLE
GATE
MECHANICAL
KEYPAD LOCK
TENSION
WIRE
5'-2" 5'-2" 5'-2"
T Y
P
11 GA. WIRE
FASTENERS,
TYP.
TIGHTENER OR TURNBUCKLE
SYMBOL,
ATTACH FABRIC TO ALL FENCE &
GATE STRUCTURES AT 12"
INTERVALS VERTICALLY & AT 20"
HORIZONTALLY.
TRUSS ROD, TYP.
TRUSS ROD
TURNBUCKLE, TYP.
BRACE RAIL
GATE RAIL,
TYP.
TENSION BAND
AND STRETCHER
BAR, TYP.
18"Ø CONCRETE
FOOTER
T Y
P
T Y
P
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S C
X X
C
H A
I N
L I N
K F
E N
C E
D
E T
S D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
CHAIN LINK FENCE
AND GATE
DETAILS
J.KEHM
D.LIRA/L.CARROLL
C2.1
SWING GATE DETAIL
NO SCALE PEDESTRIAN GATE DETAIL
NO SCALE
FENCE INSTALLATION DETAILS
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%ULEGEND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
OFFICE
OFFICE
OFFICE
COMPUTER RM
VISITOR INFO
RECEP
UTILITY
CONF.
MECH
STORAGE
STORAGE
VESTIBULE
OFFICE II
OFFICEI
OFFICE III
WOMEN
MEN
HALL
BATHROOM
BATHROOM
HALLWAY
FOYER
MECH
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S T
G
A
E
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
FLOOR PLAN
CDI
D.LIRA/L.CARROLL
A1.1
4 0 4 128
SCALE OF FEET
3/16" = 1'-0"
FLOOR PLAN
KEY NOTES
REMOVE TRIM AND SIDING ABOVE, BELOW, AND SIDES OF WINDOW.
SEAL ALL WINDOW EDGES WEATHER TIGHT. INSTALL NEW SIDING
AND TRIM.
REMOVE CARPET. INSTALL CARPET SQUARES TO MATCH EXISTING
CARPET SQUARES. TYPICAL ALL ROOMS WITH CARPET.
EXISTING CARPET SQUARES TO REMAIN, TYPICAL.
EXISTING VINYL FLOORING TO REMAIN, TYPICAL.
EXISTING CONCRETE FLOOR TO REMAIN, TYPICAL.
GENERAL NOTES
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO
CONSTRUCTION. NOTIFY CONTRACTING
OFFICER OF ANY DISCREPANCIES AFFECTING
WORK.
2. CONTRACTOR SHALL MOVE FURNITURE AS
NECESSARY FOR CARPET REPLACEMENT.
3. SEAL AROUND WINDOWS UTILIZING LOW
EXPANSION POLYURETHANE FOAM DESIGNED
TO AIR SEAL WITHOUT EXERTING PRESSURE
TO WINDOWS. COMPLY WITH AAMA 812-04
ASTM E84/UL 723, CLASS A FIRE RATED, UL
CLASSIFIED. R-VALUE OF 4.
PH1
A1.1
WINDOW AND SIDING
PH2
A1.1
PH1
A1.1
PH2
A1.1
WINDOW AND SIDING CLOSE UP
PH3
A1.1
CARPET AND CARPET TILE
PH3
A1.1
PhillipKrieble Polygon
OFFICE
OFFICE
OFFICE
COMPUTER RM
VISITOR INFO
RECEP
UTILITY
CONF.
MECH
STORAGE
STORAGE
VESTIBULE
OFFICE II
OFFICEI
OFFICE III
WOMEN
MEN
HALL
BATHROOM
BATHROOM
HALLWAY
FOYER
MECH
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S T
G
A
E
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
REFLECTED CEILING
PLAN
CDI
D.LIRA/L.CARROLL
A1.2
4 0 4 128
SCALE OF FEET
3/16" = 1'-0"
REFLECTED CEILING PLAN
KEY NOTES
REMOVE AND REPLACE 24" X 48" CEILING PANELS. MATCH EXISTING
TILES.
REMOVE AND REPLACE 30 DAMAGED 12" X 12" CEILING TILES. MATCH
EXISTING TILES. FIELD LOCATE DAMAGED TILES.
EXISTING 24" X 48" CEILING PANELS TO REMAIN.
GENERAL NOTES
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO
CONSTRUCTION. NOTIFY CONTRACTING
OFFICER OF ANY DISCREPANCIES AFFECTING
WORK.
2. TEST SAMPLING OF 12"X12" CEILING TILES AND
MASTIC FOR ASBESTOS CONTAINING MATERIAL
(ACM) PRIOR TO REMOVING. PROVIDE
CONTRACTING OFFICER WITH TEST RESULTS.
3. CONTRACTING OFFICER WILL PROVIDE
METHODS AND REQUIREMENTS IF ACM TEST
PROVES POSITIVE. COST FOR THESE
METHODS AND REQUIREMENTS ARE NOT
INCLUDED IN THIS CONTRACT.
PH2
A1.2
12" X 12" CEILING TILES
PH1
A1.2
PH2
A1.2
PH1
A1.2
2 X 4 CEILING PANELS
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S T
G
A
E
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
ROOF PLAN AND
PHOTOGRAPHS
CDI
D.LIRA/L.CARROLL
A1.3
4 0 4 128
SCALE OF FEET
3/16" = 1'-0"
ROOF PLAN
KEY NOTES
REMOVE STANDING SEAM METAL ROOF, UNDERLAYMENT, DRIP EDGE, ROOF
MOUNTED JACKS, AND ASSOCIATED EQUIPMENT. REMOVE GUTTERS AND
DOWNSPOUTS. INSTALL NEW STANDING SEAM METAL ROOF, UNDERLAYMENT,
DRIP EDGE, ROOF MOUNTED JACKS, AND ASSOCIATED EQUIPMENT. INSTALL
NEW GUTTERS AND DOWNSPOUTS. FLASH AND COUNTER FLASH ROOF
PENETRATIONS. NOT ALL ROOF PENETRATIONS SHOWN.
REMOVE AND INSTALL NEW RIDGE VENT.
INSTALL ELECTRIC HEAT PANEL. SEE DETAIL ON A1.4. TYPICAL.
INSTALL VALLEY HEAT PANEL, TYPICAL.
INSTALL NEW GUTTER AND HEAT TAPE IN GUTTER.
INSTALL DOWNSPOUT AND HEAT TAPE IN DOWNSPOUT.
REMOVE TWO 10"Ø DUCTS FROM ROOF. INSTALL CUSTOM BUILT ROOF CURB
WITH CRICKET AND TWO 10"Ø GOOSENECKS. CONNECT DUCTS TO
GOOSENECKS AND SEAL. FLASH AND COUNTER FLASH ROOF CURB.
EXISTING ROOF CURB. FLASH AND COUNTER FLASH CURB.
GENERAL NOTES
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
2. EXISTING ROOF IS METAL WITH RIBS APPROXIMATELY 24" ON
CENTER.
3. COORDINATE HEAT PANEL AND HEAT TAPE REQUIREMENTS WITH
ELECTRICAL ON E1.1.
PH4
A1.3
PH1
A1.3
PH2
A1.3
PH3
A1.3
PH5
A1.3
PH1
A1.3
GUTTER AND ROOF
PH2
A1.3
GUTTER AND ROOF
PH5
A1.3
ROOF MOUNT DUCTS
PH4
A1.3
GUTTER AND ROOF
PH3
A1.3
GUTTER AND ROOF
HEAT PANEL
FASTNER
EAVE STARTER FLASHING
"x
" DOUBLE BEAD BUTYL TAPE
FASTNER
UNDERLAYMENT
PREFINISHED GUTTER STRAP
GUTTER
SUBSTRATE
SUBSTRATE
STANDING SEAM, PANEL
AND SNAP-ON BATTEN
INSTALL HEAT TAPE
IN CHANNEL, TYPICAL
HEAT TAPE IN GUTTER
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S T
G
A
E
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
DETAILS
CDI
D.LIRA/L.CARROLL
A1.4
ELECTRIC HEAT PANEL DETAIL
NO SCALE
GENERAL NOTES
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO
CONSTRUCTION. NOTIFY CONTRACTING
OFFICER OF ANY DISCREPANCIES AFFECTING
WORK.
2. COORDINATE ROOF INSTALLATION WITH HEAT
PANEL INSTALLATION.
3. COORDINATE HEAT PANEL POWER
REQUIREMENTS WITH ELECTRICAL
INSTALLATION.
OFFICE
OFFICE
OFFICE
COMPUTER RM
VISITOR INFO
RECEP
UTILITY
CONF.
MECH
STORAGE
STORAGE
VESTIBULE
OFFICE II
OFFICEI
OFFICE III
WOMEN
MEN
HALL
BATHROOM
BATHROOM
HALLWAY
FOYER
MECH
C
PNL A
J
J
J
PNL B
PNL C
PNL SEP
O
C
O
BUS AMPS 200
MAIN CB AMPS 200
MAIN CIRCUIT BREAKER (CB)
VOLTS: 120/240 - 1 PHASE, 3 WIRE
SUBTOTAL
A
VA LOAD PER LEG
B
10,000 A.I.R.
LOAD CBDESCRIPTION &
A
MIN. WIRE SIZES TYPE AMP NO.POLE
EXISTING SERVICE ENTRANCE PANEL "SEP"
TOTAL A: 17,760 VA, 148 AMP
TOTAL B: 17,760 VA, 148 AMP
8160 8160 9600
B
MIN. WIRE SIZESAMPNO. POLE TYPE
CB LOAD DESCRIPTION &
TOTAL CONNECTED VA: 35,520
TOTAL CONNECTED AMPS: 148
TOTAL DEMAND VA: 42,240
TOTAL DEMAND AMPS: 176
ENGINE BLOCK HEATER
= GFEP CIRCUIT BREAKER (30 ma)
5 = MISCELLANEOUS
6 = SPARE
7 = SPACE
4 = KITCHEN
1 = LIGHTS
2 = RECEPTACLES
3 = MOTORS
LOAD TYPES:
MOTORS
KITCHEN
MISCELLANEOUS
LARGEST MOTOR
LIGHTS
RECEPTACLES
RECEPTACLES
26,880
8,640
CONNECTED
VA
33,600
8,640
DEMAND
VA
31002
EXISTING ELECTRICAL
OUTLETS
40 2
HEAT TAPE CONTROLLER
13 14
17 18
35,520 42,240
30 2
SURGE PROTECTION
DEVICE
(FUTURE
PANEL
SURFACE MOUNT, 3R
GATE OPERATOR
GATE OPERATOR HEATER
V A
R I E
S t o
D
D
*** 2'-0" MIN. COVER OVER ELECTRICAL
UTILITY LINE DEPTHS
6" MINIMUM BEDDING
INITIAL BACKFILL
DETECTABLE WARNING TAPE
SUBSEQUENT BACKFILL
D + 1'-0"
WIDEN TRENCH
AS NEEDED
ABOVE PIPE FOR
WORKER SAFETY
CONDUIT
GRADE
TRENCH DETAIL
NOT TO SCALE
3" GRAVEL OVER COMPACTED
BACKFILL
M
I C
H A
E L
C
U
S E
R S
T
C M
I C
H A
E L B
O X
C
D I P
K S
I B
L D
G S
F
A I R
P L A
Y R
A N
G E
R
O
F F
I C
E R
E H
A B
D
W G
S T
G
A
E
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
FAIRPLAY OFFICE
REHAB
PIKE AND SAN ISABEL
NATIONAL FORESTS
CIMARRON AND
COMANCHE NATIONAL
GRASSLANDS
SOUTH PARK RANGER
DISTRICT
02/2020 9
R2
ROCKY MOUNTAIN
REGION
F
O
R
E
S T
SE
R
V
I
C
E
D E
P
A
R
T M
E N
T
OF AGR
I C
U
L
T
U R
E
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
ELECTRICAL AND
COMMUNICATION
PLAN, PANELBOARD
AND DETAILS
CDI
D.LIRA/L.CARROLL
E1.1
4 0 4 128
SCALE OF FEET
3/16" = 1'-0"
ELECTRICAL AND COMMUNICATION PLAN
KEY NOTES
INSTALL NEW SURFACE MOUNTED JUNCTION BOX WITH DATA JACK
AND COVER PLATE. ROUTE CABLE IN SURFACE MOUNTED CONDUIT
TO TELECOM ROOM. TYPICAL.
INSTALL NEW SINGLE GANG, TWIST LOCK, L5/20R RECEPTACLE.
ROUTE CONDUCTORS IN SURFACE MOUNTED CONDUIT TO NEW
20A-1P CIRCUIT BREAKER IN PANEL C.
INSTALL 20A-1P AND 30A-2P 30mA GFEP CIRCUIT BREAKERS IN PANEL.
INSTALL 30A-2P 30mA GFEP CIRCUIT BREAKER IN PANEL.
ROUTE 2-#10 WITH #10 GROUND IN 3/4" CONDUIT FROM CONTROLLER
TO 30A-2P 30mA GFEP CIRCUIT BREAKER IN PANEL B AND TO SNOW
MELT JUNCTION BOXES. COORDINATE CONTROLLER LOCATION WITH
SNOW/ICE MELT SYSTEM ON A1.3.
INSTALL OUTLET BOX FOR SNOW SENSOR CONTROL/DISPLAY PANEL.
MOUNT CENTER OF BOX 48" ABOVE FINISHED FLOOR. ROUTE 22-5
CONDUCTOR CABLE IN 1/2" CONDUIT TO CONTROLLER.
INSTALL JUNCTION BOX BELOW EAVE FOR CONNECTION TO SNOW
MELT CABLES. COORDINATE JUNCTION BOX LOCATION WITH SNOW
MELT PANEL INSTALLATION. TYPICAL.
EXISTING ELECTRICAL PANEL TO REMAIN, TYPICAL.
EXISTING MAIN SERVICE PANEL. INSTALL 15A-2P AND 15A-1P CIRCUIT
BREAKER.
GENERAL NOTES
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO
CONSTRUCTION.
2. COORDINATE SNOW/ICE MELT ELECTRICAL
REQUIREMENTS AND LAYOUT WITH A1.3 AND
INSTALLATION.
3. SEE C1.1 FOR SITE ELECTRICAL WORK.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| G10 |
| Sheets and Views |
| G10 |
| G11 |
| Sheets and Views |
| G11 |
| C11 |
| Sheets and Views |
| C11 |
| C21 |
| Sheets and Views |
| C21 |
| A11 |
| Sheets and Views |
| A11 |
| A12 |
| Sheets and Views |
| A12 |
| A13 |
| Sheets and Views |
| A13 |
| A14 |
| Sheets and Views |
| A14 |
| E11 |
| Sheets and Views |
| E11 |
File details come from the government source that posted it. Updated .