11-Repairs of Bridge 1916 Construction Plans.pdf
PDF 3 MB Posted
- Attached to
- Repairs of Bridge 1916
- Solicitation number
- Not on record
- Issued by
- Mercer County, Pennsylvania
About this file
This is a construction plans document for Bridge 1916 repairs prepared by the Mercer County, Pennsylvania Department of Bridges in Jefferson Township. The project involves repairs to a single-span prestressed concrete adjacent box beam bridge (T-547/Hassel Road) spanning Magargee Run. The scope of work includes elimination of deflection joints, abutment repairs at both abutments, wing wall stabilization with tie-back anchors, concrete deterioration repairs, and protective coating application. Key work items include removal and replacement of deteriorated concrete (127 square feet), reinforcement bar installation (301 linear feet), repair of deteriorated concrete (10,324 square feet), earth anchors (3 anchors), verification test anchors (3 anchors), partially grouted rip rap placement (1 location), erosion and sediment pollution control, maintenance and protection of traffic, mobilization, and removal of portions of the existing bridge. Bids are due January 15, 2026 at 10:00 a.m. local time via PennBid, with work to be completed by May 20, 2026. The project requires coordination with utilities including Pennsylvania Power Co, Pin Oak Energy Partners LLC, Diamond Energy Partners, Diversified Gas and Oil, and Verizon Pennsylvania LLC, with the PA One Call System notification (Serial No. 20253532718-000) required three working days prior to excavation.
The construction plans specify use of Class AA cement concrete, epoxy-coated reinforcing steel bars meeting ASTM A 615/A 615M or equivalent standards, and structural materials conforming to AASHTO specifications. Concrete repairs must follow specified procedures including surface preparation, removal of deteriorated concrete to a minimum depth of 3/4" behind reinforcement, application of epoxy bonding compounds, and placement using either conventional or shotcrete methods. Reinforcement details include minimum embedment and splice lengths per standard drawing BC-736M, with galvanized reinforcing steel permitted as a substitute for epoxy-coated bars at no additional cost. The project requires compliance with Publication 408/2020, AASHTO/AWS welding codes, and coordination with the Pennsylvania Fish and Boat Commission prior to construction. The contractor is responsible for field verification of all dimensions, utility locations, and existing conditions, as the plans note that information regarding existing bridge conditions is not guaranteed and may differ from field conditions.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
STANDARD DRAWINGS:
DETAILS, OTHER THAN THOSE INDICATED, ARE ON THE FOLLOWING
SPECIFICATION, LATEST EDITION.
CONSTRUCT PROJECT IN ACCORDANCE WITH PUBLICATION 408
CALL BOX, OR POLICE CALL BOX.
DO NOT INTERFERE WITH THE OPERATION OF ANY FIRE HYDRANT, FIRE
THERE ARE NO NAVIGABLE STREAMS ON THIS PROJECT.
SERIAL NO 20253532718-000 FOR JEFFERSON TOWNSHIP.
CONTACT THE PA ONE CALL SYSTEM, INC., PHONE 1-800-242-1776,
THREE WORKING DAYS PRIOR TO EXCAVATION, THE CONTRACTOR MUST
CONSTRUCTION PLANS
FOR
REPAIRS OF MERCER COUNTY BRIDGE 1916
DECEMBER 2025
LOCATION MAP
SCALE: 1" = 1/2 MILE
PROJECT LOCATION
START OF ANY CONSTRUCTION ACTIVITIES.
EXACT LOCATIONS AND DEPTH OF ALL UTILITY LINES PRIOR TO THE
IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY THE
TO LOCATE BURIED UTILITIES/STRUCTURES.
NO EXCAVATIONS WERE MADE DURING THE PROGRESS OF THIS SURVEY
ADDITIONAL BURIED UTILITIES/STRUCTURES MAY BE ENCOUNTERED.
LOCATIONS SHOWN HEREON.
LOCATIONS OF UNDERGROUND UTILITIES/STRUCTURES MAY VARY FROM
ABOVEGROUND STRUCTURES AND FIELD OBSERVATIONS/SURVEY.
THE LOCATION OF UTILITIES AS SHOWN HEREON ARE BASED ON
PENNSYLVANIA POWER CO
PIN OAK ENERGY PARTNERS LLC
JEFFERSON TOWNSHIP
DIAMOND ENERGY PARTNERS
DIVERSIFIED GAS AND OIL
VERIZON PENNSYLVANIA LLC
UTILITY LIST
PA ONE CALL
ACT 287, AS AMENDED
1-
L
P E
T
-P
O
C
AL
S
N
A
N N
S Y
L V
IA
C
I N
EBE
O
F R
G
U
O
Y
I
D
LNEO CA
Y
S
M
T E
L S
PA ONE-CALL SERIAL NO. 20253532718-000 HAS BEEN ASSIGNED TO THIS PROJECT ON 12-19-2025.
SURFACE ANYWHERE IN THE COMMONWEALTH.
BY EXCAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH'S
PENNSYLVANIA ACT 287 (1974) AS AMENDED, REQUIRES NOTIFICATION
PROFESSIONAL ENGINEER
DATE
(4 SHEETS)201931,JAN.BC-783M
(3 SHEETS)202223,NOV.BC-736M
INDEX OF DRAWINGS
SHEET NO.
TITLE SHEET
GENERAL PLAN
TITLE
1 TO 5 EROSION AND SEDIMENT POLLUTION CONTROL PLAN
GENERAL NOTES AND QUANTITIES
ELIMINATE DEFLECTION JOINTS DETAILS
ABUTMENT REPAIR DETAILS I
ABUTMENT REPAIR DETAILS II
WING WALL TIE-BACK DETAILS
ALSO INCLUDED
12/18/2025
REVISIONS
Mark Description By Chk'd Recm'd. Date
RECOMMENDED
SHEET OF
DEPARTMENT OF BRIDGES
MERCER COUNTY, PENNSYLVANIA
DES: DWG: CKD:
-D
E C
-2
:3
P
L O
T T
E D
BRIDGE NO. 1916
JEFFERSON TOWNSHIP
T-547 (HASSEL RD)
OVER MAGARGEE RUN
SINGLE SPAN P/S CONCRETE ADJACENT BOX BEAM BRIDGE
43 7211 0547 1916 BMS STR ID: 26163 BRKEY:
O P
E R
A T
O R
F
IL
E N
A M
E m a r e n a
P
\0
\O
R D
\B R
I D
G E
\T S
L \B
G
P .d g n
N81°14'27"E
11 12
W ING A
W ING B W ING C
W ING D
CONSTR. �
T-547 (HASSEL ROAD)
STA AHEAD
CLEAR SPAN
38'-6"±
O U
T -T
O -O
U T
C U
R B
-T O
-C U
R B
B A
R R
IE
R
B A
R R
IE
R
M A
G A
R G
E E R
U N
BARRIER REPAIR AREA (TYP)
TY
P
6'- 0"
GROUTED RIP RAP
R-5 PARTIALLY
90°0'0"±TYP
ANCHORS. SEE SHEET 6 FOR DETAILS.
WING C TO BE STABILIZED WITH TIE-BACK
ABUT. 2ABUT. 1
GENERAL PLAN
RJP RJP/MJA MJA
WING WALL TIE-BACK DETAILS6
ABUTMENT REPAIR DETAILS II5
ABUTMENT REPAIR DETAILS I4
ELIMINATE DEFLECTION JOINT DETAILS3
GENERAL NOTES AND QUANTITIES2
GENERAL PLAN1
TITLESHEET NO.
INDEX OF DRAWINGS
DESCRIPTION DWG NO APP DATE
SUPPLEMENTAL DRAWINGS
NOV. 23, 2022
JAN. 31, 2019
BC-736M
BC-783M
REINFORCEMENT BAR FABRICATION DETAILS
REINFORCED CONCRETE REPAIR
RECOMMENDED
SHEET OF
DEPARTMENT OF BRIDGES
MERCER COUNTY, PENNSYLVANIA
DES: DWG: CKD:
-D
E C
-2
:3
P
L O
T T
E D
BRIDGE NO. 1916
JEFFERSON TOWNSHIP
T-547 (HASSEL RD)
OVER MAGARGEE RUN
SINGLE SPAN P/S CONCRETE ADJACENT BOX BEAM BRIDGE
43 7211 0547 1916 BMS STR ID: 26163 BRKEY:
O P
E R
A T
O R
F
IL
E N
A M
E m a r e n a
P
\0
\O
R D
\B R
I D
G E
\T S
L \B
G
N .d g n
GENERAL NOTES AND QUANTITIES
PUBLICATION 408/2020, SECTION 1019, TO THE BARRIERS.
APPLY PROTECTIVE COATING FOR REINFORCED CONCRETE SURFACES (PENETRATING SEALERS, BRIDGE SUPERSTRUCTURE) IN ACCORDANCE WITH
PROTECTIVE COATING NOTES:
IDENTIFIED ON THE PLANS.
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH UTILITIES AND ANY COSTS ASSOCIATED WITH UTILITY ADJUSTEMENTS NOT
THE NEED FOR UTILITY ADJUSTMENTS SHALL BE DETERMINED BY CONTRACTOR AS REQUIRED FOR CONTRACTOR'S MEANS AND METHODS.
105.06 AND 107.12.
COORDINATE, LOCATE AND CONDUCT ALL WORK RELATED TO PUBLIC AND PRIVATE UTILITIES IN ACCORDANCE WITH PUBLICATION 408, SECTIONS
UTILITIES:
CONSTRUCTION.
VERIFY ALL DIMENSIONS AND GEOMETRY OF THE EXISTING STRUCTURE IN THE FIELD AS NECESSARY FOR PROPER FIT OF THE PROPOSED
CONDITIONS AFFECTING THE COSTS AND/OR QUANTITIES OF WORK PERFORMED MAY DIFFER FROM THOSE INDICATED.
THAT INFORMATION IS CORRECTLY SHOWN. THE BIDDER IS NOT TO RELY ON THIS INFORMATION BUT IS TO ASSUME THE POSSIBLITY THAT
CONSIDERED A BASIS FOR COMPUTATION OF THE UNIT PRICES USED FOR BIDDING PURPOSES. THERE IS NO EXPRESSED OR IMPLIED AGREEMENT
THE INFORMATION SHOWN ON THE PLANS FOR THE EXISTING BRIDGE IS NOT PART OF THE PLANS, PROPOSAL, OR CONTRACT AND IS NOT TO BE
FIELD.
BY THE OWNER OR ITS AUTHORIZED AGENTS AS POSITIVE REPRESENTATIONS OF ANY OF THE CONDITIONS THAT YOU WILL ENCOUNTER IN THE
DO NOT CONSIDER ANY OF THE DATA ON THE EXISTING STRUCTURE SUPPLIED IN THE ORIGINAL DESIGN DRAWINGS OR MADE AVAILABLE TO YOU
EXISTING BRIDGE PLANS:
PROVIDE MINIMUM EMBEDMENT AND SPLICE LENGTHS IN ACCORDANCE WITH STANDARD DRAWING BC-736M, UNLESS OTHERWISE INDICATED.
WELDING OF REINFORCEMENT BARS DURING FABRICATION OR CONSTRUCTION IS NOT PERMITTED UNLESS SPECIFIED.
OWNER.
GALVANIZED REINFORCING STEEL BARS MAY BE SUBSTITUTED FOR EPOXY-COATED REINFORCING STEEL BARS AT NO ADDITIONAL COST TO THE
USE EPOXY-COATED REINFORCEMENT BARS IN ALL COMPONENTS UNLESS OTHERWISE NOTED.
REINFORCING BARS IN BRIDGE ABUTMENTS, BARRIERS OR WHERE BENDING OR WELDING OF THE REINFORCEMENT BARS IS INDICATED.
PROPORTIONAL INCREASE IN CROSS-SECTIONAL AREA, IF APPROVED BY THE CHIEF BRIDGE ENGINEER. DO NOT USE RAIL STEEL A 996/A 996M
WELD GRADE 60 REINFORCING STEEL BARS UNLESS SPECIFIED. GRADE 40 REINFORCING STEEL BARS MAY BE SUBSTITUTED WITH A
PROVIDE GRADE 60 REINFORCING STEEL BARS THAT MEET THE REQUIREMENTS OF ASTM A 615/A 615M, A 996/A 996M OR A 706/A 706M. DO NOT
:REINFORCEMENT
CHAMFER EXPOSED CONCRETE EDGES 3/4 IN. BY 3/4 IN., EXCEPT AS NOTED.
A HIGHER CLASS CONCRETE MAY BE SUBSTITUTED FOR A LOWER CLASS CONCRETE AT NO ADDITIONAL COST TO THE OWNER.
USE CLASS AA CEMENT CONCRETE IN ABUTMENT & BARRIER REPAIRS.
PROVIDE 2 IN. CONCRETE COVER ON REINFORCEMENT BARS, EXCEPT AS NOTED.
:ONCRETEC
PHONE: (814) 337-0444
MEADVILLE, PA 16335
11528 STATE HIGHWAY 98
NORTHWEST REGIONAL OFFICE
PENNSYLVANIA FISH AND BOAT COMMISSION
CONSTRUCTION.
NOTIFY THE REGIONAL HEADQUARTERS OF THE FISH COMMISSION PRIOR TO CONSTRUCTION AND COOPERATE WITH FISH COMMISSION DURING
SUPERSTRUCTURE DIMENSIONS SHOWN ARE FOR A NORMAL TEMPERATURE OF 68° F.
ALL DIMENSIONS ARE IN FEET, UNLESS OTHERWISE NOTED.
ALL DIMENSIONS SHOWN ARE HORZONTAL, EXCEPT AS NOTED.
GENERAL CONSTRUCTION:
NOTED OTHERWISE.
PROVIDE STRUCTURAL STEEL CONFORMING TO AASHTO M270/M270M, GRADE 50 (ASTM A709/A709M, GRADE 50) DESIGNATION, EXCEPT WHEN
PROVISIONS.
AASHTO/AWS D1.1/D1.1M:2015 FOR WELDING NOT COVERED IN AASHTO/AWS D1.5M/D1.5:2015) BRIDGE WELDING CODE AND CONTRACT SPECIAL
PROVIDE MATERIALS AND PERFORM WORK IN ACCORDANCE WITH SPECIFICATIONS, PUBLICATION 408/2020, AASHTO/AWS D1.5M/D1.5:2015 (USE
GENERAL NOTES:
REPAIR CONCRETE DAMAGED DURING REPAIR OPERATIONS TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST. -
COMPOUND THAT IS NO LONGER TACKY. WIRE BRUSH OR ABRASIVE BLAST HARDENED COMPOUND AND RECOAT REPAIR AREA.
CEMENT CONCRETE WITH NO. 8 COARSE AGGREGATE. DO NOT PLACE CONCRETE IF COMPOUND IS NO LONGER TACKY OR HAS HARDENED. RECOAT CONVENTIONAL METHOD: APPLY EPOXY BONDING COMPOUND TO REPAIR AREAS. WHILE EPOXY BONDING COMPOUND IS STILL TACKY, PLACE CLASS AA -
A SURFACE WITH FREE SURFACE WATER.
SURFACES TO A SATURATED SURFACE DRY (SSD) CONDITION BEFORE APPLICATION OF SHOTCRETE. DO NO APPLY SHOTCRETE TO A DRY SURFACE, OR TO SHOTCRETE METHOD: SATURATE PREPARED CONCRETE SUBSTRATE WITH CLEAN WATER THE DAY BEFORE SHOTCRETE APPLICATION. BRING WETTED -
AIR-BLAST REPAIR AREAS WITH OIL-FREE COMPRESSED AIR TO PROTECT AGAINST CONTAMINANTS DETRIMENTAL TO THE BOND OF NEW CONCRETE. -
MAINTAIN EXISTING CHAMFERS. -
OUTWARD.
PROVIDE MINIMUM CONCRETE COVER OF 2”. IF ENOUGH CONCRETE COVER ON EXISTING REINFORCEMENT BARS IS NOT AVAILABLE, HAUNCH REPAIR -
ATTACH WWF TO THE BENT "L" REINFORCEMENT BARS WITH ANNEALED IRON WIRE AT A MAXIMUM SPACING OF 1'-0" IN EACH DIRECTION.
PLACE EPOXY COATED NO. 4 BENT “L” REINFORCMENT BARS IN A 1’-0” CENTER-TO-CENTER MAXIMUM SPACED GRID. ANCHOR INTO SOUND CONCRETE. -
BARS.
ABRASIVE BLAST EXPOSED REINFORCEMENT BARS TO NEAR-WHITE METAL (RUST AND MILL SCALE REMOVED). EPOXY COAT EXPOSED REINFORCEMENT AFTER REMOVAL OPERATIONS ARE COMPLETE, CLEAN REMAINING DEBRIS AND LOOSE MATERIALS FROM REPAIR AREAS BY ABRASIVE BLASTING. -
OUTLINED REPAIR AREA, ENLARGE AREA AS DIRECTED BY THE OWNER.
HAMMERS, IF REQUIRED, NOT EXCEEDING AN IMPACT RATING OF 30 FOOT POUNDS. IF DETERIORATED CONCRETE EXTENDS BEYOND THE INITIALLY SQUARE-OUT/BEVEL EDGE OF REPAIR AREAS TO KEY IN CONSTRUCTION. USE HAND TOOLS FOR REMOVING DETERIORATED CONCRETE. USE PNEUMATIC -
DEPTH OF 3/4” BEHIND REINFORCEMENT BARS, DO NOT REMOVE ADDITIONAL CONCRETE WITHOUT APPROVAL OF THE OWNER.
SOUND CONCRETE. ALLOW UNCOVERED OR EXPOSED REINFORCEMENT BARS TO HAVE A 3/4” CLEARANCE ALL AROUND. IF CONCRETE IS UNSOUND AT WITHIN THE OUTLINED REPAIR AREAS, REMOVE DETERIORATED CONCRETE TO A DEPTH OF 3/4” BEHIND THE FIRST MAT OF REINFORCEMENT BARS TO -
OUTLINE EDGE OF THE DESIGNATED REPAIR AREAS WITH 1” MAXIMUM DEPTH SAWCUT. -
SOUND AND DETERMINE EXTENT OF REPAIR AREAS IN THE PRESENCE OF OWNER. -
REMOVAL, REPAIR AREA PREPARATION AND REINFORCEMENT INSTALLATION.
CONSTRUCTION PROCEDURE FOR DETERIORATED CONCRETE REPAIR
EJT EJT MJA
1---------LSEROSION AND SEDIMENT POLLUTION CONTROLSSP9000-4002
41---41---SYPARTIALLY GROUTED RIP RAPSP9000-3001
1---1---EAVERIFICATION TEST ANCHORSP9000-2002
3---3---EAEARTH ANCHORSSP9000-2001
127---10324SFREPAIR DETERIORATED CONCRETESP9000-1002
44------CYCLASS AA CEMENT CONCRETE, MODIFIEDSP9000-1001
1---------LSREMOVAL OF PORTION OF EXISTING BRIDGE, MODIFIEDSP1018-0051
301301------LBREINFORCEMENT BARS---1002-0001
1---------LSMAINTENANCE AND PROTECTION OF TRAFFIC DURING CONSTRUCTIONSP0901-0001
1---------LSMOBILIZATION---0608-0001
TOTALSUPERABUT 2ABUT 1UNITDESCRIPTIONNOTEITEM NO
APPROXIMATE QUANTITIES
SP - SEE SPECIAL PROVISION
RECOMMENDED
SHEET OF
DEPARTMENT OF BRIDGES
MERCER COUNTY, PENNSYLVANIA
DES: DWG: CKD:
-D
E C
-2
:1
P
L O
T T
E D
BRIDGE NO. 1916
JEFFERSON TOWNSHIP
T-547 (HASSEL RD)
OVER MAGARGEE RUN
SINGLE SPAN P/S CONCRETE ADJACENT BOX BEAM BRIDGE
43 7211 0547 1916 BMS STR ID: 26163 BRKEY:
O P
E R
A T
O R
F
IL
E N
A M
E m a r e n a
P
\0
\O
R D
\B R
I D
G E
\T S
L \B
B P
.d g n
2'-6" 2'-6"
REMOVE AND REPLACE
EXISTING CONCRETE
1" SAWCUT (TYP) TO REMAIN (TYP.)
EXISTING REINFORCEMENT
(TO BE REMOVED)
EXISTING DEFLECTION JOINT
5'-0"
RETAINED FROM BEAM
MATCH WITH BARS
4 SETS OF 2 - P501
LONG. BARS
LAP EXIST.
7 - P401
EXISTING REINFORCEMENT
TO REMAIN
TOP OF BARRIER
TOP OF ROADWAY
BOTTOM OF BARRIER
LONG. BARS
LAP EXIST.
2 - P302
RETAINED FROM BEAM
MATCH WITH BARS
4 - P301
MIN. LAP (TYP)
2'-3"
1'-3"
9"
"8
PARAPET & REPLACE)
(REMOVE AS NEEDED TO FORM
2 1/2" BITUMINOUS SURFACE
P401
(MATCH TO EXISTING)
(MATCH TO RETAINED BEAM BARS)
P501
(MATCH TO RETAINED BEAM BARS)
P301
(MATCH TO EXISITNG)
P302
L
IM
IT
S
O F
P R
O T
E C
T
IV
E C
O A
T
IN
G
F O
R R
E
IN
F O
R C
E D
C O
N C
R E
T E
S U
R F
A C
E S
P
E N
E T
R A
T
IN
G S
E A
L E
R S
B R
ID
G
E S
U P
E R
S T
R U
C T
U R
E S
TO REMAIN (TYP.)
EXISTING REINFORCEMENT
(MATCH TO EXISTING)
P401
3/4" DRIP NOTCH
TO REMAIN (TYP.)
EXISTING P/S ADJACENT BOX BEAM
6 0 6 12 INCHES
DEFLECTION JOINT ELEVATION
6 0 6 12 INCHES
DEFLECTION JOINT SECTION
ELIMINATE DEFLECTION JOINTS DETAILS
EJT EJT RJP
(2 JT EACH SIDE)
A
B
C
ROCK, CLASS R-5
SELECTED BORROW EXCAVATION
AASHTO NO. 57, TYPE A
GEOTEXTILE CLASS 4, TYPE A
AASHTO NO. 57, TYPE A
REVISIONS
Mark Description By Chk'd Recm'd. Date
RECOMMENDED
SHEET OF
DEPARTMENT OF BRIDGES
MERCER COUNTY, PENNSYLVANIA
DES: DWG: CKD:
-D
E C
-2
:1
P
L O
T T
E D
BRIDGE NO. 1916
JEFFERSON TOWNSHIP
T-547 (HASSEL RD)
OVER MAGARGEE RUN
SINGLE SPAN P/S CONCRETE ADJACENT BOX BEAM BRIDGE
43 7211 0547 1916 BMS STR ID: 26163 BRKEY:
O P
E R
A T
O R
F
IL
E N
A M
E m a r e n a
P
\0
\O
R D
\B R
I D
G E
\T S
L \B
A B
T .d g n
(TO REMAIN)
EXISTING CONCRETE
CONSTR �
T-547 (HASSEL ROAD)
TO FRONT FACE OF ABUTMENT
LIMIT OF CONCRETE REPAIR APPLIES
B8 B7 B6 B5 B4 B3 B2 B1
2'-0"*
2'-10"*
3'-0"*
*1'-6"*
1'-0"* 3
9"*
9"*
(TO REMAIN)
EXISTING CONCRETE
CONSTR �
T-547 (HASSEL ROAD)
TO FRONT FACE OF ABUTMENT
LIMIT OF CONCRETE REPAIR APPLIES
B1 B2 B3 B4 B5 B6 B7 B8
"*8'-5"*6'-8"*
5'-11"*
2'-0"*
6'-3"*
1'-0"*
1 0 1 2 FEET
ABUTMENT 2 ROCK PROTECTION DETAIL
GROUTED RIP RAP
R-5 PARTIALLY 2'-0"
FF EXISTING ABUTMENT
4" DIA WEEPHOLE
BOTTOM OF EXISTING FOOTING
EXISTING GROUND
PLACEMENT LIMITS
STREAMBED AT THE PGR
FLUSHED/BLENDED WITH NATURAL
GROUTED RIP RAP (PGR) SHALL BE
FINAL ELEVATION OF PARTIALLY
6'-0"
GEOTEXTILE
COMBINED FILTER
ABUTMENT REPAIR DETAILS I
EJT EJT
FOR CONCRETE REPAIR DETAILS, SEE SHEET 5.3.
2. FOR GENERAL NOTES, SEE SHEET 2.
1. FOR GENERAL PLAN, SEE SHEET 1.
NOTES:
WING A WING B
WING C WING D
LEGEND:
REPAIR AREA
APPROXIMATE CONCRETE
2 0 2 4 FEET
ABUTMENT 1
B1 DENOTES EXISTING BEAM
2 0 2 4 FEET
ABUTMENT 2
MJA
SHOWN SHALL BE APPROVED BY OWNER.
MINIMUM. CONCRETE REPAIRS BEYOND THE LIMITS
* DIMENSIONS FOR REPAIR AREAS SHOWN ARE
SHOWN SHALL BE APPROVED BY OWNER.
MINIMUM. CONCRETE REPAIRS BEYOND THE LIMITS
* DIMENSIONS FOR REPAIR AREAS SHOWN ARE
COMBINED FILTER DETAIL
(NOT TO SCALE)
RECOMMENDED
SHEET OF
DEPARTMENT OF BRIDGES
MERCER COUNTY, PENNSYLVANIA
DES: DWG: CKD:
-D
E C
-2
:3
P L
O T
T E
D
BRIDGE NO. 1916
JEFFERSON TOWNSHIP
T-547 (HASSEL RD)
OVER MAGARGEE RUN
SINGLE SPAN P/S CONCRETE ADJACENT BOX BEAM BRIDGE
43 7211 0547 1916 BMS STR ID: 26163 BRKEY:
O P
E R
A T
O R
F
IL
E N
A M
E m a r e n a
P
\0
\O
R D
\B R
I D
G E
\T S
L \B
A B
T .d g n
X
PATCH 1" MIN
OF WIRE BACK INTO
WIRE MESH. BEND EDGES
2X2-W4.0XW4.0 WELDED
EDGE OF UNDERCUT
LIMIT OF DETERIORATION
MAX
6"
LENGTH OF HOOK
90° HOOK AND 2"
SLOPE @ 5H TO 1V (TYP)
" DIA DOWEL WITH2
EXISTING BAR
WITH ENDS BELOW/BEHIND
EPOXY COATED TIE WIRE
5H TO 1V (TYP)
DOWELS ARE SLOPED @
12"± EACH WAY (TYP)
1/2" DIA DOWEL SPACED @
1" DIA X 9" DEEP HOLE WITH
DOWEL HOLES USING GROUT
ARE ANCHORED INTO THE
CONCRETE AND THE DOWELS
IS REMOVED TO SOUND
DETERIORATED CONCRETE
CONCRETE REPAIR AFTER
M A
X
12"
A
A
CONCRETE REPAIR DETAIL
CONCRETE
EXISTING
NOT TO SCALE
REINFORCEMENT
EXISTING
AND SPACING
REINFORCEMENT. MATCH SIZE
NEEDED. LAP TO EXISTING
NEW REINFORCEMENT STEEL AS
TYPICAL CORNER REPAIR DETAIL
MAX
6"
MIN
4"
SAW CUT (TYP)
" TO 1"4
CONSTRUCTION (TYP)
BEVEL EDGE TO KEY IN
FORMED SURFACE
ON EITHER SIDE OF CORNER
OFFSET DOWELS BY 6"
NEW CONCRETE
WWF TIED TO DOWELSCONCRETE
SOUND
NOT TO SCALE
SECTION A-A
DOWEL HOLES USING GROUT
ARE ANCHORED INTO THE
CONCRETE AND THE DOWELS
IS REMOVED TO SOUND
DETERIORATED CONCRETE
CONCRETE REPAIR AFTER
5H TO 1V (TYP)
DOWELS ARE SLOPED @
12"± EACH WAY (TYP)
1/2" DIA DOWEL SPACED @
1" DIA X 9" DEEP HOLE WITH
CONCRETE
EXISTING
LIMIT OF REMOVAL
1" MIN
FROM SURFACE OF PATCH
" DOWEL BAR2
1" MIN CLR TO
TO SURFACE OF PATCH
1" MIN / 2" MAX WELDED WIRE FABRIC
EPOXY COATED TIE WIRE
PATCH 1" MIN
OF WIRE BACK INTO
WIRE MESH. BEND EDGES
2X2-W4.0XW4.0 WELDED
2" MAX
" MIN2
1" MIN
SPACED 12" OC IN FIELD
" DOWEL WITHIN 6" OF PERIMETER,2
NOT TO SCALE
TYPICAL DOWEL DETAIL
NEW CONCRETE
" DOWEL2
WWF
WITH ANNEALED IRON WIRE
FASTEN WWF TO DOWELS
GROUTED HOLE
1" DIA X 9" DEEP
CONCRETE
SOUND
APPLY EPOXY BONDING COMPOUND COVER
1"
COVER
"2
SURFACE
FORMED
NOT TO SCALE
ABUTMENT REPAIR DETAILS II
RJP RJP MJA
2. FOR ADDITIONAL CONCRETE REPAIR TYPE 2A DETAILS, SEE BC-738M
FOR ABUTMENT REPAIR DETAILS, SEE SHEET 4. 1.
NOTES:
RECOMMENDED
SHEET OF
DEPARTMENT OF BRIDGES
MERCER COUNTY, PENNSYLVANIA
DES: DWG: CKD:
-D
E C
-2
:4
P
L O
T T
E D
BRIDGE NO. 1916
JEFFERSON TOWNSHIP
T-547 (HASSEL RD)
OVER MAGARGEE RUN
SINGLE SPAN P/S CONCRETE ADJACENT BOX BEAM BRIDGE
43 7211 0547 1916 BMS STR ID: 26163 BRKEY:
O P
E R
A T
O R
F
IL
E N
A M
E m a r e n a
P
\0
\O
R D
\B R
I D
G E
\T S
L \B
W
I N
G .d g n
1'-0" 4'-6"4'-6"
ELEV 95.13
TFE 90.13
BFE 88.13
12'-0"
(TYP)
� ANCHOR
ELEV 94.23
ELEV 95.55
ELEV 92.92
BEARING PLATE (TYP)
1" x 1'-1" x 1'-1"
EXISTING WING WALL C
ELEV 102.13
M
IN
E M
B E
D M
E N
T D
E P
T H
90°0'0"
PLATIPUS B08 OR APPROVED EQUAL.
PERCUSSION DRIVEN EARTH ANCHOR.
#7 GR. 75 ALL-THREAD BAR
EXISTING GROUND
EXISTING WING WALL C
°0 '0
AFTER ANCHOR INSTALLATION
FILL VOID WITH NON-SHRINK GROUT
FOR ANCHOR INSTALLATION.
NEAT SAW CUT OR CORED HOLE
BETWEEN BEARING PLATE AND CONCRETE
PROVIDE ELASTOMERIC BEDDING MATERIAL
NUT AND BEVELED WASHER
WING WALL TIE-BACK DETAILS
DGS DGS MJA
1 0 1 2 FEET
WING WALL C TIE-BACK TYPICAL SECTION
1 0 1 2 FEET
WING WALL C TIE-BACK ELEVATION
6. ELASTOMERIC BEDDING MATERIAL SHALL MEET REQUIREMENTS OF PUB. 408 SECTION 1113.03(h).
LOCKING AND PROOF TESTING HAS BEEN PERFORMED.
5. MINIMUM EMBEDMENT DEPTH SHOWN FOR ANCHOR SHALL BE FINAL ANCHOR POSITION AFTER LOAD-
" DIA.2
14. OPENING THROUGH WALL FOR EARTH ANCHOR INSTALLATION SHALL NOT BE LARGER THAN 10
CUTTING OR CORING THE WALL. EXISTING REINFORCEMENT SHALL NOT BE CUT OR DAMAGED.
3. LOCATE EXISTING REINFORCEMENT USING A PACHOMETER OR OTHER APPROVED METHOD PRIOR TO
2. FOR GENERAL NOTES, SEE SHEET 2.
1. FOR GENERAL PLAN, SEE SHEET 1.
NOTES
| 01-GENERAL PLAN |
| 02-GENERAL NOTES |
| 03-DEFLECTION JOINTS DETAILS |
| 04-ABUTMENT REPAIR DETAILS 1 |
| 05-ABUTMENT REPAIR DETAILS II |
| 06-WING WALL TIE-BACK DETAILS |
| T0033660447TI_1916 |
| 02-GENERAL NOTES |
| T0033660447TI_1916 |
| 06-WING WALL TIE-BACK DETAILS |
File details come from the government source that posted it. Updated .