02-20R_Construction_Plans.pdf

PDF 2 MB Posted

Attached to
River City Nature Park Restroom Addition
Solicitation number
02-20R
Issued by
Volusia County, Florida

About this file

This is a construction plans document prepared by CPH, Inc., a full-service architectural and engineering firm, for the City of DeBary in Volusia County, Florida, detailing the River City Nature Park Restroom Addition project. The project involves the installation of a prefabricated restroom building with an attached slab at River City Nature Park located at 200 Barwick Road, DeBary, Florida 32713. The construction plans include a site layout showing the proposed restroom facility, water line connections extending approximately 1,745 linear feet of 2-inch polyethylene water main with directional drilling components, a septic system with a 900-gallon septic tank, and an associated drain field. The plans were prepared by Jeremiah D. Owens, P.E. (FL License 6503), and include three main sheets: a cover sheet with project location map, an aerial and site dimension plan, and detailed septic system specifications and diagrams.

The septic system design is configured for a sewage flow of 200 gallons per day with a drain field area of 333 square feet minimum based on a sewage loading rate of 0.60 gallons per square foot per day. All design and installation must comply with Florida Administrative Code Chapter 64E-6 regarding on-site sewage disposal systems and state health department standards. The project is federally assisted and subject to Davis-Bacon Act prevailing wage requirements, Copeland Act anti-kickback provisions, and other federal labor standards including bonding requirements per 24 CFR 85.36, Section 3 compliance, and minority/women-owned business enterprise (M/WBE) considerations. The prime contractor is responsible for wage compliance enforcement and maintenance of support documentation throughout the project duration.

View the file

Other files

File Type Posted
NOTICE_OF_AWARD.pdf PDF
02-20R_Addendum_1_-_River_City_Restroom.pdf PDF
02-20R_Project_Manual.pdf PDF
02-20R_Bid_Form.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SITE

Project Location Map

SCALE: 1" = 2000'

PROJECT LOCATION

www.cphcorp.com

Architects

Engineers

Environmental

Landscape Architects

M / E / P

Planners

Structural

Surveyors

Traffic / Transportation

Offices in:

· Florida

· Puerto Rico

· Connecticut

· Maryland

· Texas

A Full Service A & E Firm

500 West Fulton St.

Sanford, Fl. 32771

Ph: 407.322.6841

Licenses:

Eng. C.O.A. No. 3215

Survey L.B. No. 7143

Arch. Lic. No. AA2600926

Lndscp. Lic. No. LC0000298

CPH, Inc.

Plans Prepared By:

D r a w n b y

D e s i g n e d b y

A p p r o v e d b y

C h e c k e d b y

D a t e

N o

12345

S c a l e

J o b

N o

D a t e

Sheet No.

C

R e v i s i o n

B y

D

C O

V E

R

S

H E

E T

A S

N

O T

D

V

L U

S I

C

U

N T

Y

F

L O

R I D

A

J e r e m i a h

D

O w e n s

P

E

F L

P

E

C I T

Y

O

F

D

E B

A R

Y

R I V

R

T

Y

N

A T

U R

E

P

A R

K

State Map

Sheet Index

1 COVER SHEET

2 AERIAL AND SITE DIMENSION PLAN

RIVER CITY NATURE PARK

200 Barwick Rd, DeBary, FL 32713

CONSTRUCTION PLANS

FOR

CITY OF DEBARY

VOLUSIA COUNTY, FLORIDA

Plans Prepared By:

A FULL SERVICE ARCHITECTURAL/ENGINEERING FIRM

Plans Prepared For:

3 SEPTIC SYSTEM DETAILS

TIE-IN TO EXISTING WATER SOURCE

WITH TAPPING SLEEVE AND VALVE

(SEE DETAIL THIS SHEET)

1,745 LF

2" WATER MAIN (POLY)

DRAIN FIELD

AND SEPTIC

PAVILION

(BY OTHERS)

PROPOSED RESTROOM

66.75' LF. ~

DIRECTIONAL DRILL

100.00'

DIRECTIONAL DRILL

SEE INSET NOS. 1 AND 2 BELOW

M

E

M

E

APPROXIMATE LOCATION

OF EXISTING 4" WATER MAIN

SITE BENCHMARK #1

TREE TO BE REMOVED

EXISTING

2" WATER MAIN

5' SIDEWALK (TYP)

(BY OTHERS)

PROPOSED RESTROOM

32 LF 6" PVC @ 0.47%

6" C.O. W/ WYE.

(SEE DETAIL THIS SHEET)

REDUCED PRESSURE BACKFLOW

PREVENTION ASSEMBLY

3/4" METER AND BOX

19.3' X 4.5' SIDEWALK

P

A

V

I

L

I

O

N

B

Y

H

E

R

S

6" CLEANOUT

(SEE DETAIL THIS SHEET) 2.50' (TYP)

7.13' (TYP)

EXISTING

CONCRETE PARKING

(TO REMAIN)

900 GAL. SEPTIC TANK

P

R

O

P

O

S

E

D

D

R

A

F

E

L

D

20' LONG DRAIN PIPES @ 0.25% (TYP.)

12 LF 6" @ 0.42%

6 LF 6" PVC @ 1.0%

SITE BENCHMARK #2

SITE BENCHMARK #1

PROPOSED RESTROOM

P

A

V

I

L

I

O

N

H

E

R

S

M.E.

M.E.

19.3

19.3

19.5

19.5

19.5

19.5

M

E

M

E

P

R

O

P

O

S

E

D

D

R

A

E

L

D www.cphcorp.com

Architects

Engineers

Environmental

Landscape Architects

M / E / P

Planners

Structural

Surveyors

Traffic / Transportation

Offices in:

· Florida

· Puerto Rico

· Connecticut

· Maryland

· Texas

A Full Service A & E Firm

500 West Fulton St.

Sanford, Fl. 32771

Ph: 407.322.6841

Licenses:

Eng. C.O.A. No. 3215

Survey L.B. No. 7143

Arch. Lic. No. AA2600926

Lndscp. Lic. No. LC0000298

CPH, Inc.

Plans Prepared By:

D r a w n b y

D e s i g n e d b y

A p p r o v e d b y

C h e c k e d b y

D a t e

N o

12345

S c a l e

J o b

N o

D a t e

Sheet No.

C

R e v i s i o n

B y

D

A E

R I A

L

A

T

E

D

I M

E N

S I O

N

P

L

T

L U

S

U

N T

Y

F

L O

R I D

A

J e r e m i a h

D

O w e n s

P

E

F L

P

E

C I T

Y

O

F

D

E B

A R

Y

R I V

T

Y

N

A T

U R

E

P

A R

K

N

N

RESTRAINED

MECHANICAL JOINT

EXISTING

PIPE

TEST PLUG

NEW PIPE

MJ TAPPING SLEEVE

RESILIENT SEAT TAPPING VALVE

WITH VALVE BOX (TYP.)

RESTRAINED

MECHANICAL JOINT

TEST PLUG

TAPPING SLEEVE & TAPPING VALVE

N.T.S.

PROFILE

PLAN

THREADED WATERTIGHT PLUG

BRONZE OR CAST IRON IN

PAVED OR CONCRETE AREAS

10" SQ. X 8" DEEP

CONCRETE PAD

45° BEND

F

I

R

J

I

N

T

M

X

T

E R

M I N

E D

4" LATERAL

TO SEPTIC TANK TO BUILDING

WYE (4" X 4")

SEWER CLEANOUT

N.T.S.

6" CLEAN-OUT 12" X 12" X 4" THK. CONC.

COLLAR W/ #4 BAR

6" 45° BEND

8" PLUG

8" X 6" WYE

8" PVC UNDERDRAIN

TYPICAL CLEANOUT

N.T.S.

N

M

I N

EXISTING GRAVEL ROAD

WIDTH VARIES

VARIES

VARIES

EXISTING 4" WATER MAIN

WATER LINE TYPICAL SECTION

N.T.S.

WATER MAIN ALIGNMENT

SCALE: 1" = 100'

SITE DIMENSION PLAN (INSET NO. 1)

SCALE: 1" = 20'

SITE GRADING PLAN (INSET NO. 2)

SCALE: 1" = 20'

19.35

15.85

15.70

15.65

15.60

INV. 16.10

19.35

E

X

I

S

T

I

G

N

C

E

M

O

V

E

D

4.00' aswift Line aswift Line aswift Oval aswift Cloud

0.00 aswift Rectangle jowens Typewriter

ELECTRICAL SERVICE POLE

jowens Typewriter

METER AND PANEL

jowens Polyline

SECTION THRU SEPTIC TANK SYSTEM

SEPTIC TANK PLAN VIEW

DRAINFIELD DIAGRAM

SECTION AT DRAINFIELD

SEWER CLEANOUT

6. SEPTIC TANK CONCRETE SHALL BE A MINIMUM OF 4,000 PSI. 28 DAY STRENGTH.

7. MINIMUM FREE BOARD OR AIR SPACE SHALL BE 15% OF AFFECTIVE TANK CAPACITY.

8. SEPTIC TANK SHALL BE MANUFACTURED BY A HEALTH DEPARTMENT APPROVED

MANUFACTURER AND MARKED AS REQUIRED BY FLORIDA ADMINISTRATIVE CODE 64E-6.

1. SUBSURFACE SEWAGE DISPOSAL SYSTEM SHALL COMPLY WITH STATE OF FLORIDA

DEPARTMENT OF HEALTH CHAPTER 64E-6 OF THE FLORIDA ADMINISTRATIVE CODE

2. THE SEWAGE DISPOSAL SYSTEM IS CONFIGURED TO PROVIDE THE FOLLOWING MINIMUM

CLEARANCES TO EXISTING/PROPOSED STRUCTURES:

DISTANCE TO PRIVATE POTABLE WELL

(AS MEASURED FROM NEAREST CORNER OF DRAINFIELD.......................EXCEEDS 75'

DISTANCE TO PUBLIC POTABLE WELL SYSTEM.........................................EXCEEDS 200'

DISTANCE TO NONPOTABLE WELL ...........................................................EXCEEDS 50'

DISTANCE TO LIMITED USE

NONCOMMUNITY OR OTHER PUBLIC POTABLE WATER WELL....................EXCEEDS 150'

DISTANCE TO POTABLE WELL LINE...........................................................EXCEEDS 10'

DISTANCE TO STRUCTURE FOUNDATIONS..................................................EXCEEDS 5'

DISTANCE TO MEAN HIGH WATER LINE OF

TIDAL WATERS, STREAMS, CANALS AND DRAINAGE STRUCTURES.............EXCEEDS 75'

DISTANCE TO DESIGN HIGH WATER LINE OF

INDIVIDUAL STORM WATER DRY RETENTION AREAS..................................EXCEEDS 15'

DISTANCE TO PROPERTY LINE..................................................................EXCEEDS 5'

3. SEPTIC TANK EFFECTIVE CAPACITY OF 900 GALLONS, BASED ON ESTIMATED SEWAGE FLOW

OF 200 GALLONS PER DAY (200 GPD). MANUFACTURED IN COMPLIANCE WITH SECTION

4. DRAINFIELD AREA OF 333 SQ.FT.(MINIMUM) BASED ON SEWAGE LOADING RATE TO BED

BOTTOM OF 0.60 GALLONS PER SQUARE FOOT PER DAY.

5. RETENTION POND SEASONAL HIGH WATER TABLE ELEVATION = 16.50 N.G.V.D.

(FAC) "STANDARDS FOR ON-SITE SEWAGE DISPOSAL SYSTEMS"

64E-6.013 FAC.

www.cphcorp.com

Architects

Engineers

Environmental

Landscape Architects

M / E / P

Planners

Structural

Surveyors

Traffic / Transportation

Offices in:

· Florida

· Puerto Rico

· Connecticut

· Maryland

· Texas

A Full Service A & E Firm

500 West Fulton St.

Sanford, Fl. 32771

Ph: 407.322.6841

Licenses:

Eng. C.O.A. No. 3215

Survey L.B. No. 7143

Arch. Lic. No. AA2600926

Lndscp. Lic. No. LC0000298

CPH, Inc.

Plans Prepared By:

D r a w n b y

D e s i g n e d b y

A p p r o v e d b y

C h e c k e d b y

D a t e

N o

12345

S c a l e

J o b

N o

D a t e

Sheet No.

C

R e v i s i o n

B y

D

S E

P T

S

T E

M

D

E T

A I L

T

L U

S

U

N T

Y

F

L O

R I D

A

J e r e m i a h

D

O w e n s

P

E

F L

P

E

C I T

Y

O

F

D

E B

A R

Y

R I V

T

Y

N

A T

U R

E

P

A R

K

19.50

15.60

13.00

15.65 21.33

15.85

19.30

16.10

19.00

16.50

19.50

15.60

15.10

13.10

13.00

File details come from the government source that posted it. Updated .