About this opportunity
Atlantic County, New Jersey is requesting bids on alterations to Classroom No. 4 at the Canale Fire Training Center (5033 English Creek Avenue, Egg Harbor Township), with bids due August 6, 2026. The scope includes selective demolition of existing ceiling, lighting, mechanical, and fire protection systems; installation of new ceiling, mechanical, lighting, electrical, and sound reinforcement systems; and restoration of finishes damaged by the work. A/V equipment removal and installation will be performed under a separate contract.
Work must achieve substantial completion within 91 consecutive calendar days from notice to proceed and final completion within 112 consecutive calendar days. Liquidated damages of $500 per consecutive calendar day apply for delays. The contractor is responsible for securing all necessary permits and governmental approvals at its own cost, daily debris removal, site restoration, and compliance with PEOSH guidelines and applicable codes. Temporary facilities (toilets, wash facilities, drinking water) must be provided by the contractor; water and electric power from the County's existing systems are available without metering or use charges.
The contract is a lump-sum proposal with no unit pricing or alternates. A $30,000 contingency allowance is included in the base bid for unforeseen items or additional work, requiring prior written approval from the Director of Atlantic County Facilities Management before work commences. The source encourages contractors to visit the site prior to bidding to assess existing conditions and determine project difficulties. Questions are due before the August 6 proposal deadline.
Opportunity text
2 versions
Update #2 · Latest ·
The Canale Fire Training Center Classroom No. 4 Alterations project consists of alterations to its existing lighting, electrical, and mechanical systems and new sound reinforcement systems. The scope of the work is to include, but is not limited to, the following: 1. Limited selective demolition, including the removal of existing ceiling systems, lighting fixtures and mechanical systems to the extent indicated within the Contract Documents and as required to accommodate the proposed construction. 2. Restoration of finishes damaged as a result of the work of this Contract. 3. Installation of new ceiling systems. 4. New mechanical systems indicated and scheduled, and modification of existing systems as indicated within the Contract Documents. 5. Alterations to the existing fire protection systems indicated. It shall be the responsibility of the 6. New lighting systems indicated and scheduled. 7. New sound reinforcement systems indicated and scheduled. 8. New electrical systems indicated and scheduled, as required to provide support the work of this contract. B. The A/V work, including the removal of the existing systems and supply and installation of new A/V equipment will, be performed under the scope of a separate contract.
Update #1 ·
Classroom acoustic renovations at the AC Canale Fire Training Center