Z1DA--Overhead Paging System
Closed Solicitation Posted
- Solicitation number
- 36C24620R0144
- Agency
-
Veterans Integrated Service Network 6
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Durham Nc Usa
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks proposals for an overhead paging system project at the Durham VA Medical Center. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 seeks to provide a new in-building mass notification system covering Buildings 1 and 23 to facilitate public and code blue announcements, allow for future expansion, and integrate with existing nurse call and fire alarm systems. Proposals are due February 2, 2021 and will be evaluated based on technical qualifications, past performance, and price.
There is no set-aside designation. The associated NAICS code is 236220 for commercial and institutional building construction with a small business size standard of $39.5 million. The project is located at the Durham VA Medical Center and involves installing new fiber optic runs, amplifiers, equipment, and overhead speakers across two buildings to be completed within 180 days of award.
Notice text
2 versions
Update #2 · Latest ·
The subsequent solicitation is a request for proposal (RFP). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2020-06, Effective May 6, 2020. The associated North American Industrial Classification System (NAICS) code for this procurement is 236220, with a small business size standard of $39.5 Million. The solicitation will be posted on or about 10/1/2020 The project is located at the Durham VA Medical Center. The project s purpose is as follows: PURPOSE The purpose of this project is to provide a new In-Building Mass Notification system for the Durham VAMC that will cover buildings 1 & 23 in order to facilitate public and code blue announcements. The system shall allow for later expansion in order to expand coverage to those areas, and to other buildings on campus. Paging zones for the system will be assigned based on existing building wings. The emergency and psychology departments will only have speakers at the nurses stations and will not have speakers in the corridors. The rest of the facility will have speakers in the corridors and select meeting rooms. The Fire Alarm system will take precedence over all Nurse Call system and Mass Notification System announcements as follows: Interface of the In-Building Mass Notification system to the Fire Alarm system will be done via contact closure controlled by the Fire Alarm system. The contact closure will be active during any active audio message from either internal pre-recorded message or fire alarm microphone. When the contact is active, the In-Building Mass Notification system will immediately suspend all audio distribution until the contact closure returns to a non- emergency state. Nurse Call System to interface with the new In-Building Mass Notification system. The In-Building Mass Notification system takes all interfaces from the Nurse Call System and allows for all code messages to be recalled/played from the nurse station or head end board interface. This allows the roaming nurses to take the paging station with them to make pages, trigger an alarm, or trigger a recorded message. It will also enable text to speech messaging as part of the system. There is no existing PAMNS system on campus, except for an addition on building 23, and there are no existing fiber runs that can be utilized. This system will add new fiber runs between the amplifiers and equipment locations and the system head-end equipment location. The existing system in the addition made to building 23 will be connected to the new system to be installed as part of this project. Apogee will utilize existing conditioned rooms in order to avoid adding a mechanical/HVAC component to this project.
Update #1 ·
The subsequent solicitation is a request for proposal (RFP). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2020-06, Effective May 6, 2020. The associated North American Industrial Classification System (NAICS) code for this procurement is 236220, with a small business size standard of $39.5 Million.
The solicitation will be posted on or about 10/1/2020
The project is located at the Durham VA Medical Center. The project s purpose is as follows:
PURPOSE
The purpose of this project is to provide a new In-Building Mass Notification system for the Durham VAMC that will cover buildings 1 & 23 in order to facilitate public and code blue announcements. The system shall allow for later expansion in order to expand coverage to those areas, and to other buildings on campus. Paging zones for the system will be assigned based on existing building wings. The emergency and psychology departments will only have speakers at the nurses stations and will not have speakers in the corridors. The rest of the facility will have speakers in the corridors and select meeting rooms.
The Fire Alarm system will take precedence over all Nurse Call system and Mass Notification System announcements as follows:
Interface of the In-Building Mass Notification system to the Fire Alarm system will be done via contact closure controlled by the Fire Alarm system. The contact closure will be active during any active audio message from either internal pre-recorded message or fire alarm microphone. When the contact is active, the In-Building Mass Notification system will immediately suspend all audio distribution until the contact closure returns to a non- emergency state.
Nurse Call System to interface with the new In-Building Mass Notification system. The In-Building Mass Notification system takes all interfaces from the Nurse Call System and allows for all code messages to be recalled/played from the nurse station or head end board interface. This allows the roaming nurses to take the paging station with them to make pages, trigger an alarm, or trigger a recorded message. It will also enable text to speech messaging as part of the system.
There is no existing PAMNS system on campus, except for an addition on building 23, and there are no existing fiber runs that can be utilized. This system will add new fiber runs between the amplifiers and equipment locations and the system head-end equipment location. The existing system in the addition made to building 23 will be connected to the new system to be installed as part of this project. Apogee will utilize existing conditioned rooms in order to avoid adding a mechanical/HVAC component to this project.
Files
| File | Type | Posted |
|---|---|---|
| 36C24620R0144 0003.pdf | ||
| 01T-101A - Building 1 Ground Floor New Work - Area A - RFI Revisions 1 - 12-17-2020.pdf | ||
| 36C24620R0144 0002.docx | DOCX document | |
| 36C24620R0144 0001.docx | DOCX document | |
| Pre-proposal Site Investigation Attendance.pdf | ||
| Overhead Paging System - Specifications.pdf | ||
| Overhead Paging System - Drawings.pdf | ||
| 36C24620R0144_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Z1DA--Overhead Paging System | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--Renovate Space for Patient Care Improvements | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--612A4-27-018 | Replace B650 3rd and 2nd Flooring | Veterans Integrated Service Network 21 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--PCAC EHRM Infrastructure Upgrades Construction - Togus VAMC (VA-27-00009716) | VA Technology Acquisition Center | No set-aside | |
| Z2DA--Construct Inpatient Tower 7th Floor, Cincinnati, OH | VA Technology Acquisition Center | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity