Z1DA--506-17-503 Chiller Plant Optimization
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25020B0063
- Agency
- Veterans Integrated Service Network 10 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Ann Arbor MI 48105 USA
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, VA Medical Center in Ann Arbor, Michigan seeks to award a firm fixed price contract to optimize operations at the facility's central chiller plant. The scope of work includes rerouting primary and secondary chilled water piping, tying together cooling tower basins, coating interior surfaces and modifying controls to improve efficiency and reduce manpower. The contractor must be able to complete all work within 270 calendar days and meet the requirements outlined in solicitation number 36C25020B0063. Interested parties should monitor beta.SAM.gov as the solicitation containing specifications, drawings and other documents will be available for download beginning June 10, 2020, with responses due on a date specified within.
The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses. The primary NAICS code is 238990 for commercial and institutional building construction with a size standard of $16.5 million. The government estimates the contract value to be between $500,000 and $1 million. The place of performance is the VA Medical Center located at 2215 Fuller Road, Ann Arbor, Michigan 48105. The contract is to be awarded within 120 days of bid receipt and all work must be completed from within the 270-day period of performance at this location.
Notice text
2 versions
Update #2 · Latest ·
This is a pre-solicitation announcement for the Department of Veterans Affairs, VA Medical Center, located in Ann Arbor, MI. An Invitation for Bid (IFB) will be issued on this Federal Business Opportunities (www.fbo.gov) website on or about June 10, 2020 for construction project no. 506-17- Chiller Plant Optimization at the Ann Arbor VA Medical Center, Ann Arbor, Michigan. The VA is seeking a qualified Contractor to furnish all tools, equipment, material, permits, labor, and supervision necessary to accomplish, the work as provided in the contract documents, plans, and specifications, a summary of which is provided below: Furnish all necessary labor, tools, miscellaneous materials, equipment, and supervision as specified in drawings and specifications to complete 506-17- Chiller Plant Optimization at the Ann Arbor VA Medical Center, Ann Arbor, Michigan. This project will include: This is intended to improve the performance of the felicities 3 existing water-cooled centrifugal chillers in the central chiller plant located in Building 32. The facility has 2 800-ton chillers and 1 1,000-ton chiller currently operating in the central chiller plant. Rerouting Primary and Secondary Chilled water Loop piping, including removal and replacement the decoupler loop between the Primary and Secondary chilled water loops. Tying the cooling tower basins together, coating the interior of the cooling towers and modifying controls for the cooling tower to improve performance efficiency and reduce manpower necessary to maintain proper operations of the cooling towers through automation. Eliminate 3-way chilled water valves, as identified on the project drawings to help improve the delta T between the chilled water supply and the chilled water return. Add more sensors into the chilled water system to allow greater and more effective control of the system. Modify existing control sequences for the chillers, chiller staging, primary chilled water pumps, Secondary chilled water pumps, cooling towers etc. to dramatically improve system efficiency, and facility ability to fully utilize its installed chiller capacity. The IT Security requirements for Certification & Accreditation requirements do not apply and a Security Accreditation Package is not required. The contractor and all sub-contractors will be required to complete annual privacy training by reading and signing the Privacy Training TMS 20939 prior to beginning any work. The General Contractor will receive a total of 270 days to complete the construction. The North American Industry Classification Code (NAICS) for this procurement is 238990 Commercial and Institutional Building Construction and size standard $16.5 million applies. In accordance with VAAR 836.204, disclosure of the magnitude of this construction project is between $500,000 and $1,000,000. The Government intends to award a Firm Fixed Price Contract within 120 days from bid receipt date. This notice is for informational purposes only and is not a request for submission of offers. No other information regarding scope, dates, etc. is available until issuance of the solicitation via Contract Opportunities. As authorized by FAR 5.102, solicitation dissemination is limited to electronic medium, and the VA will provide no hard copies. The solicitation, consisting of various RFP documents, specifications, forms, and drawings will be available for download at no charge only from the beta.SAM.gov on or about June 10, 2020 with a due date to be specified in the solicitation. Further details of all dates and events, including site visit and IFB due date, will be available in the solicitation. FBO is the only website where official IFB documents will be made available. All interested offers (prime contractors & subcontractors) should register at beta.SAM.gov so that others will know of your interest in participating in this procurement. An Offeror's list is not maintained nor distributed by the Contracting Officer, as it is the offeror's responsibility to register at the FBO website. Offerors are advised that they are responsible for obtaining all bid documents and acknowledging any amendments and should re-visit the beta.SAM.gov website periodically to check for any changes to this announcement or pending solicitation. Prospective contractors shall complete electronic annual representations and shall be registered in the System for Award Management (SAM) at http:// beta.SAM.gov shall be verified in the Vetbiz Registry Information Pages prior to submitting an offer and shall have on file a current and complete VETS4212 report at http://www.dol.gov/vets/vets-100.html (if applicable). Address all questions in writing to the issuing office via email to reginald.williams2@va.gov. No fax or telephone inquiries will be answered. No other information regarding scope, dates, etc. is available until issuance of the solicitation.
Update #1 ·
This is a pre-solicitation announcement for the Department of Veterans Affairs, VA Medical Center, located in Ann Arbor, MI. An Invitation for Bid (IFB) will be issued on this Federal Business Opportunities (www.fbo.gov) website on or about June 10, 2020 for construction project no. 506-17- Chiller Plant Optimization at the Ann Arbor VA Medical Center, Ann Arbor, Michigan.
The VA is seeking a qualified Contractor to furnish all tools, equipment, material, permits, labor, and supervision necessary to accomplish, the work as provided in the contract documents, plans, and specifications, a summary of which is provided below:
Furnish all necessary labor, tools, miscellaneous materials, equipment, and supervision as specified in drawings and specifications to complete 506-17- Chiller Plant Optimization at the Ann Arbor VA Medical Center, Ann Arbor, Michigan. This project will include:
This is intended to improve the performance of the felicities 3 existing water-cooled centrifugal chillers in the central chiller plant located in Building 32. The facility has 2 800-ton chillers and 1 1,000-ton chiller currently operating in the central chiller plant.
Rerouting Primary and Secondary Chilled water Loop piping, including removal and replacement the decoupler loop between the Primary and Secondary chilled water loops.
Tying the cooling tower basins together, coating the interior of the cooling towers and modifying controls for the cooling tower to improve performance efficiency and reduce manpower necessary to maintain proper operations of the cooling towers through automation.
Eliminate 3-way chilled water valves, as identified on the project drawings to help improve the delta T between the chilled water supply and the chilled water return.
Add more sensors into the chilled water system to allow greater and more effective control of the system.
Modify existing control sequences for the chillers, chiller staging, primary chilled water pumps, Secondary chilled water pumps, cooling towers etc. to dramatically improve system efficiency, and facility ability to fully utilize its installed chiller capacity.
The IT Security requirements for Certification & Accreditation requirements do not apply and a Security Accreditation Package is not required. The contractor and all sub-contractors will be required to complete annual privacy training by reading and signing the Privacy Training TMS 20939 prior to beginning any work.
The General Contractor will receive a total of 270 days to complete the construction.
The North American Industry Classification Code (NAICS) for this procurement is 238990 Commercial and Institutional Building Construction and size standard $16.5 million applies. In accordance with VAAR 836.204, disclosure of the magnitude of this construction project is between $500,000 and $1,000,000. The Government intends to award a Firm Fixed Price Contract within 120 days from bid receipt date. This notice is for informational purposes only and is not a request for submission of offers. No other information regarding scope, dates, etc. is available until issuance of the solicitation via Contract Opportunities.
As authorized by FAR 5.102, solicitation dissemination is limited to electronic medium, and the VA will provide no hard copies. The solicitation, consisting of various RFP documents, specifications, forms, and drawings will be available for download at no charge only from the beta.SAM.gov on or about June 10, 2020 with a due date to be specified in the solicitation. Further details of all dates and events, including site visit and IFB due date, will be available in the solicitation. FBO is the only website where official IFB documents will be made available.
All interested offers (prime contractors & subcontractors) should register at beta.SAM.gov so that others will know of your interest in participating in this procurement. An Offeror's list is not maintained nor distributed by the Contracting Officer, as it is the offeror's responsibility to register at the FBO website. Offerors are advised that they are responsible for obtaining all bid documents and acknowledging any amendments and should re-visit the beta.SAM.gov website periodically to check for any changes to this announcement or pending solicitation. Prospective contractors shall complete electronic annual representations and shall be registered in the System for Award Management (SAM) at http:// beta.SAM.gov shall be verified in the Vetbiz Registry Information Pages prior to submitting an offer and shall have on file a current and complete VETS4212 report at http://www.dol.gov/vets/vets-100.html (if applicable).
Address all questions in writing to the issuing office via email to reginald.williams2@va.gov. No fax or telephone inquiries will be answered. No other information regarding scope, dates, etc. is available until issuance of the solicitation.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C25020B0063 0003.docx | DOCX document | |
| 36C25020B0063 0002.docx | DOCX document | |
| Covid Instructions.docx | DOCX document | |
| 506-17-503 RFI.docx | DOCX document | |
| 36C25020B0063 0001.docx | DOCX document | |
| Specification -STRUCTURAL STEEL FRAMING.docx | DOCX document | |
| 506-17-503 Drawing - Building 32 - Roof Level.pdf | ||
| Ann Arbor Chiller Plant Optimization - Project RFI Questions r1.pdf | ||
| 506-17-503 Drawing -Building 32 - Pipping Plan.pdf | ||
| Pre-Bid Attendance.pdf | ||
| 36C25020B0063.docx | DOCX document | |
| WD MI20200100 rev 7-10-2020.txt | TXT text file | |
| 506-17-503 Contractor EMR Certification Form 2020.docx | DOCX document | |
| 506-17-503 Drawings.pdf | ||
| 506-17-503 - Specifications.pdf | ||
| 506-17-503 PM_Part808.405-6_Atch1_Limiting_Sources_Justification_MPT-SAT - Siemens (003)- CORRECTED.pdf | ||
| S02 - RFI Form 506-17-503.docx | DOCX document |
Show all 17
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--506-17-503 Chiller Plant Optimization | Award Notice | |
| Z1DA--506-17-503 Chiller Plant Optimization | Solicitation | |
| Z1DA--506-17-503 Chiller Plant Optimization | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity