This document contains an amendment to a solicitation and related federal contract opportunity. The amendment changes the bid opening date for solicitation number 36C25020B0063 from August 31, 2020 at 1:00 PM to September 10, 2020 at 1:00 AM. It provides answers to requests for information, project drawings, specifications, and a pre-bid attendance sheet. The related federal contract opportunity is for project number 506-17-503 to improve the performance of three existing water-cooled centrifugal chillers at the central chiller plant located in Building 32 at the Department of Veterans Affairs Medical Center in Ann Arbor, Michigan. The project scope includes rerouting primary and secondary chilled water piping, tying together cooling tower basins, coating interior surfaces, modifying controls, eliminating three-way chilled water valves, and adding sensors to improve system efficiency and utilization of installed chiller capacity. The contract type will be firm-fixed-price with a period of performance of 270 days. The estimated value is between $500,000 and $1,000,000. The solicitation will be issued on or around June 10, 2020 via SAM.gov.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25020B0063 0003.docx | DOCX document | |
| 36C25020B0063 0002.docx | DOCX document | |
| 506-17-503 RFI.docx | DOCX document | |
| Covid Instructions.docx | DOCX document | |
| 506-17-503 Drawing -Building 32 - Pipping Plan.pdf | ||
| Pre-Bid Attendance.pdf | ||
| Specification -STRUCTURAL STEEL FRAMING.docx | DOCX document | |
| 506-17-503 Drawing - Building 32 - Roof Level.pdf | ||
| Ann Arbor Chiller Plant Optimization - Project RFI Questions r1.pdf | ||
| 36C25020B0063.docx | DOCX document | |
| WD MI20200100 rev 7-10-2020.txt | TXT text file | |
| 506-17-503 - Specifications.pdf | ||
| 506-17-503 PM_Part808.405-6_Atch1_Limiting_Sources_Justification_MPT-SAT - Siemens (003)- CORRECTED.pdf | ||
| S02 - RFI Form 506-17-503.docx | DOCX document | |
| 506-17-503 Contractor EMR Certification Form 2020.docx | DOCX document | |
| 506-17-503 Drawings.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36C25020B0041 – Project 506-17-503 Chiller Plant Optimization – Ann Arbor C=VAMC, Ann Arbor Mi
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
06-18-2020
506-17-503
Department of Veterans Affairs Network Contracting Office (NCO) 10 6150 Oak Tree Blvd., Suite 300
Independence OH 44131
Department of Veterans Affairs Network Contracting Office (NCO) 10 6150 Oak Tree Blvd., Suite 300
Independence OH 44131 To all Offerors/Bidders
36C25020B0063
X x
The pupose of this amendment is to change or correct the following.
1. The BID Opening is hereby changed 8-31-2020 at 1:00PM to 9-10-2020 at 1:00 AM. Call in information provide.
2. To provide RFI answers, drawings and specification.
3. To provide the site visit sign in sheet
3. All other conditions remains the same.
RICHMOND L. MCCLOUD
Contract Specialist
CONTINUATION PAGE
1. There is NO visitor access to Dominos Farm. Contracting personnel will be waiting by the entrance to Lobby M to receive dropped off bids. You may drop off your bid, observing social distancing, and call in from your vehicles.
2. VANTS LINE: 1 844-825-8490 CODE 196609162#; may join at 10:50PM Local Time.
Join by phone
| 844-825-8490,7466798899# (South) | English (United States) |
| 844-352-6288,7466798899# (South) | English (United States) |
| 844-355-6288,7466798899# (South) | English (United States) |
Conference ID: 7466798899
Page 1 of
Page 1 of
See attached document: Ann Arbor Chiller Plant Optimization - Project RFI Questions r1.
See attached document: 506-17-503 Drawing -Building 32 - Pipping Plan.
See attached document: Specification -STRUCTURAL STEEL FRAMING.
See attached document: 506-17-503 Drawing - Building 32 - Roof Level.
See attached document: Pre-Bid Attendance.
File details come from the government source that posted it. Updated .