Y1DZ--NRM - CON - 561A4-18-101 Replace Central Chillers -Construction

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24223B0035
Agency
Veterans Integrated Service Network 2 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
Y1DZ Construction Of Other Hospital Buildings
Place of performance
151 Knollcroft Rd Lyons, NJ 07939, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks construction services to replace two central chillers and associated equipment at the Lyons VA Medical Center located at 151 Knollcroft Rd, Lyons, NJ. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is seeking offers to demolish the existing chillers and install two new magnetic bearing chillers, pumps, switchgear including transformers and switchboards, and perform controls integration work. Bids are due by August 30, 2023 and will be evaluated based on price. The period of performance is 365 calendar days from notice to proceed.

This opportunity is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses. The primary NAICS code is 238220 for plumbing, heating, and air conditioning contractors. The place of performance is the Lyons VA Medical Center located at 151 Knollcroft Rd, Lyons, NJ. The government estimates a budget between $5-10 million to replace the two 750-ton chillers and associated electrical and mechanical equipment. The construction services must be completed within 365 calendar days of award.

Notice text

5 versions

Update #5 · Latest ·

Amendment 0004 to IFB 36C24223B0035

1 - Amendment it to provide Addendum 2 from AE as follows:

Reference key note #1 on drawing 136-MH-101:

Revise Construction Key Note #1 to read:

Provide new Refrigerant gas leak detection system to replace existing.

New system shall be Genesis International`, Inc. Sherlock 802 with Optional Strobe Refrigerant gas leak an Monitoring and alarming system (SHER802-S). Provide Two Sensors per Chiller for 3 chillers. For a total of 6. Plus, Provide one additional Oxygen Depletion Sensor. Install per manufactures recommendations below new and existing chillers. Connect to existing BAS system. Remove existing system.

Equipment shall be or as approved equal. See attached data sheet for further information.

2 - Additional correction regarding amendment posted 08/17/2023, the correct pump schedule is as follows:

On Drawing 136-MH-701 - Pump Schedule Circulating Fluid Head (FT):

P-4 Revise - Head (FT): from 25 to 60 FT.

P-5 Revise - Head (FT): from 35 to 60 FT.

P-6 Revise - Head (FT): from 35 to 60 FT.

P-8 Revise - Head (FT): from 55 to 92 FT.

P-9 Revise - Head (FT): from 50 to 100 FT.

Update #4 ·

Additional RFI Follow Ups:

1. Clarification to RFI #8c. Since the feeders - GRC conduit and conductors - to be, now, provided by the electrical contractor, we are assuming underground conduit installation between the disconnects (new and the existing ones) and the temporary chillers.

a) Should this installation be removed after temp chillers are decommissioned and removed from the site? YES

b) if so, can the installation be considered "temporary" and maybe surface-mounted utilizing, let's say PVC conduit in lieu of GRC? NO

2. Clarification to RFI #9. It is clearly understood that the conduits in question (related to the HV feeders), are to be installed in GRC conduits. What about the interior conduits as depicted on ES-102? Should they also be installed utilizing GRC conduit? Can EMT be utilized for indoor applications? There is a note on ED-102, related to the WC- feeder to its 5KV starter clearly stating of existing GRC conduit. Please advise: ALL HV FEEDERS TO BE IN GRC CONDUIT

3. Is the work outlined in RFI #46 (the added ATS #2) to be included as part of the contract's "Base Bid" or to be priced as a separate add alternate? TO BE PART OF BASE BID

The following are also additional updates provided by the AE as an Addendum to the Bidders.

On drawings and specification Delete all references to R-134A and Insert R-513A in same location.

On Drawing 136-MH-701 - Pump Schedule Circulating Fluid Head (FT):

P-4 Revise - Head (FT): from 25 to 60 FT.

P-5 Revise - Head (FT): from 35 to 60 FT.

P-6 Revise - Head (FT): from 35 to 60 FT.

P-7 Revise - Head (FT): from 55 to 92 FT.

P-8 Revise - Head (FT): from 50 to 100 FT.

Update #3 ·

Amendment 0002 for IFB 36C24223B0035.

Amendment provides the following:

Clarification that location for this project is the Lyons VAMC

Equipment schedule referenced in RFI #4

Power Systems study as requested in RFI #13

Updated RFI spreadsheet

Photos of roof that was not accessible during site visit

Update #2 ·

AMENDMENT

Update #1 ·

Invitation For Bid #36C24223B0035 to Replace Central Chillers at the Lyons VAMC

Attachments

Files attached to this notice, newest first
File Type Posted
36C24223B0035 0004.docx DOCX document
Sherlock 802 with Opitional Strobe.pdf PDF
36C24223B0035 0003.docx DOCX document
CEI085065 - LYONS VA - POWER SYSTEM STUDY 6-1-09.pdf PDF
561A4-18-101 Replace Central Chillers RFI for Construction - with updates.pdf PDF
20-105 Refrigeration Machine Schedule (8-1-23).xlsx XLSX spreadsheet
36C24223B0035 0002.docx DOCX document
Roof Pictures.pdf PDF
561A4-18-101 Replace Central Chillers RFI for Construction.pdf PDF
S04 - Site Visit Sign In.pdf PDF
36C24223B0035 0001.docx DOCX document
Contract Drawings.pdf PDF
S02 - Wage Determination 07-03.pdf PDF
Contract Specifications.pdf PDF
S02 - Buy American Certificate.pdf PDF
36C24223B0035_2.docx DOCX document
Show all 16

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Y1DZ--561A4-18-101 Replace Central Chillers Award Award Notice
Y1DZ--NRM - CON - 561A4-18-101 Replace Central Chillers -Construction This notice · Latest solicitation Solicitation
Y1DZ--561A4-18-101 Replace Central Chillers Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity