Ultra Highspeed Megapixel CMOS Imaging Camera

Closed Special Notice Posted

Solicitation number
NINDS09426
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Bethesda, Maryland 20892, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The National Institutes of Health is announcing a sole-source intent to award a firm-fixed-price purchase order to Vision Research Inc. for one PHANTOM VEO 1310L ultra high-speed megapixel CMOS imaging camera with 72GB mono memory, with a response deadline of September 23, 2026 at 10:00 a.m. EST. The camera will support Parkinson's Disease research conducted by the Cellular Neurophysiology Section at the National Institute of Neurological Disorders and Stroke, specifically to image dopamine neurons using fluorescent voltage indicators and capture action potentials at frame rates of 10 kilohertz or above with high sensitivity to low light levels and minimal pixel noise.

Vision Research Inc. is identified as the sole known responsible source capable of meeting the technical requirements under FAR 6.302-1. Small businesses, including 8(a) firms, service-disabled veteran-owned, HUBZone, small disadvantaged, veteran-owned, and women-owned small businesses, may submit written capability statements demonstrating their ability to perform the requirement to tianna.gladney@nih.gov by the deadline. All travel, labor, materials, and related charges are included in the purchase order price. Award is anticipated approximately five days after the notice date, contingent on government determination that no other organization can meet the requirements.

Notice text

This acquisition is to purchase of a ultra high speed megapixel CMOS imaging camera (PHANTOM VEO 1310L, MONO 72GB MEMORY) from Vision Research Inc. The ultra high speed imaging camera from Vision Research will be used in experiments that will be performed by the Cellular Neurophysiology Section at the National Institute of Neurological Disorders and Stroke (CNS/NINDS). The experiments being performed will directly test the effects of alterations in neural circuitry in various animal models of Parkinson’s Disease. Specifically, we are interested in understanding how synaptic and intrinsic conductances expressed on these neurons differ among subpopulations dopamine neurons. We are also interested in understanding how the synaptic and circuit connections onto these cells control their activity and ultimately how they contribute to dopamine dependent behaviors and dysfunction. The hope that this information may provide insight to why SNc dopamine neurons are particularly vulnerable in Parkinson’s disease.  Our goal is to identify novel physiological and genetic markers in single SNc dopamine neurons which may be useful in defining subpopulations of these neurons.  

To study the circuits that control midbrain dopaminergic neurons, experimenters in the Cellular Neurophysiology Section prepare tissue slices that will be mounted on an electrophysiology setup. Although electrophysiological recordings provide high temporal resolution and require highly specialized knowledge in order to have consistent success. To increase the successful acquisition of this information, we will use an imaging system that will allow us to perform imaging using fluorescent voltage indicators in which the fluorescence intensity correlate to the neuronal membrane voltage. The major component of this system is a high speed camera that is highly sensitive to moderately low light levels and can also image at frame rates that reach at 10 kilohertz or above. This requirement is necessary because action potentials occur at 1 ms. Using the voltage imaging approach, we will be able to image large populations of neurons, tens to hundreds, simultaneously which is not possible using standard electrophysiology approaches such as patch clamp. Lastly, the camera should have the lowest pixel noise possible so that signal to noise ratio can be maximized for use voltage-indicators that have only small changes fluorescence changes in their signal. 

Files

File Type Posted
PCA-NINDS-09426 NOI.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Service agreement for the Nikon AXR-NSPARC confocal Bethesda, Maryland 20892, United States Office of Logisitics and Acquisition Operations No set-aside
Goldeye Camera Washington, District of Columbia 20375, United States · NAICS 334516 Office of Naval Research Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity