Level I Confinement Facility Addition - Hill Air Force Base (HAFB), Utah
Closed Solicitation Posted
- Solicitation number
- W9123823R0047
- Agency
-
ENDIST Sacramento
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Competitive 8(a)
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Y1FF Construction Of Penal Facilities
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation from the Department of the Army Corps of Engineers Engineering District Sacramento seeks a contractor to provide a single story addition to an existing Level I Regional Confinement Facility at Hill Air Force Base in Utah. The masonry cavity wall construction with flat metal roof must include administrative areas, visitation/training room, waiting area, day room and outdoor recreation area. Additional requirements include fire suppression, utilities, communications, site improvements and support facilities. The design must comply with Department of Defense, Air Force and base standards and integrate sustainable principles. Proposals are due by August 11, 2023 and will be evaluated based on technical qualifications, past performance and price.
This competitive 8(a) set-aside opportunity has a NAICS code of 236220 with construction scheduled to be completed within 12 months of the award date. As the placed of performance is Hill Air Force Base in Utah, the awarded firm must follow all Department of Defense antiterrorism and force protection guidelines. The project budget is estimated between $2-5 million to accommodate the four additional cells needed within the existing Level I Regional Confinement Facility at building 408 on base.
Notice text
6 versions
Update #6 · Latest ·
** Amendment 0005 to solicitation W9123823R0047 adds Attachment 22 - Arch Drawings, Attachment 23 - Section 08 51 23, and Attachment 24 - Updated Interior Sheets ** ** Amendment 0004 to solicitation W9123823R0047 deletes Attachment 1 - Civil Sheets in its entirety and provides clarification regarding Attachment 17 - Civil Sheets. ** Amendment 0003 to solicitation W9123823R0047 extends the proposal due date and adds additional attachments; Uploads Amendment 0002 Attachment 16 (Site Visit Roster) to PIEE ** Amendment 0002 to solicitation W9123823R0047 provides 1) an update to Section VIII (Evaluation Approach) of solicitation section 00 22 00 - Supplementary Instructions, and 2) adds Attachment 16 - Site Visit Roster ** Amendment 0001 to solicitation W9123823R0047 provides updated site visit information under FAR provision 52.236-27 (Alternate I) ** The contractor shall provide a single story, Level I Regional Confinement Facility addition to Building 408, Security Forces Operations Center to accommodate a four-cell requirement in accordance with Air Force Instruction 31-205 Air Force Corrections System. The masonry cavity wall construction with a flat metal roof will include administrative areas, visitation/training room, waiting area, a day room, and outdoor recreation area. The project also will include fire suppression system, all utilities, communications, site improvements, and associated support facilities. The facility will be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used were cost effective. The facility will be designed as permanent construction in accordance with Unified Facilities Criteria 1-200-01, General Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facilities Criteria 1-200-02, High Performance and Sustainable Building Requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01.
Update #5 ·
** Amendment 0004 to solicitation W9123823R0047 deletes Attachment 1 - Civil Sheets in its entirety and provides clarification regarding Attachment 17 - Civil Sheets. ** Amendment 0003 to solicitation W9123823R0047 extends the proposal due date and adds additional attachments; Uploads Amendment 0002 Attachment 16 (Site Visit Roster) to PIEE ** Amendment 0002 to solicitation W9123823R0047 provides 1) an update to Section VIII (Evaluation Approach) of solicitation section 00 22 00 - Supplementary Instructions, and 2) adds Attachment 16 - Site Visit Roster ** Amendment 0001 to solicitation W9123823R0047 provides updated site visit information under FAR provision 52.236-27 (Alternate I) ** The contractor shall provide a single story, Level I Regional Confinement Facility addition to Building 408, Security Forces Operations Center to accommodate a four-cell requirement in accordance with Air Force Instruction 31-205 Air Force Corrections System. The masonry cavity wall construction with a flat metal roof will include administrative areas, visitation/training room, waiting area, a day room, and outdoor recreation area. The project also will include fire suppression system, all utilities, communications, site improvements, and associated support facilities. The facility will be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used were cost effective. The facility will be designed as permanent construction in accordance with Unified Facilities Criteria 1-200-01, General Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facilities Criteria 1-200-02, High Performance and Sustainable Building Requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01.
Update #4 ·
** Amendment 0003 to solicitation W9123823R0047 extends the proposal due date and adds additional attachments; Uploads Amendment 0002 Attachment 16 (Site Visit Roster) to PIEE ** Amendment 0002 to solicitation W9123823R0047 provides 1) an update to Section VIII (Evaluation Approach) of solicitation section 00 22 00 - Supplementary Instructions, and 2) adds Attachment 16 - Site Visit Roster ** Amendment 0001 to solicitation W9123823R0047 provides updated site visit information under FAR provision 52.236-27 (Alternate I) ** The contractor shall provide a single story, Level I Regional Confinement Facility addition to Building 408, Security Forces Operations Center to accommodate a four-cell requirement in accordance with Air Force Instruction 31-205 Air Force Corrections System. The masonry cavity wall construction with a flat metal roof will include administrative areas, visitation/training room, waiting area, a day room, and outdoor recreation area. The project also will include fire suppression system, all utilities, communications, site improvements, and associated support facilities. The facility will be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used were cost effective. The facility will be designed as permanent construction in accordance with Unified Facilities Criteria 1-200-01, General Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facilities Criteria 1-200-02, High Performance and Sustainable Building Requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01.
Update #3 ·
** Amendment 0002 to solicitation W9123823R0047 provides 1) an update to Section VIII (Evaluation Approach) of solicitation section 00 22 00 - Supplementary Instructions, and 2) adds Attachment 16 - Site Visit Roster ** Amendment 0001 to solicitation W9123823R0047 provides updated site visit information under FAR provision 52.236-27 (Alternate I) ** The contractor shall provide a single story, Level I Regional Confinement Facility addition to Building 408, Security Forces Operations Center to accommodate a four-cell requirement in accordance with Air Force Instruction 31-205 Air Force Corrections System. The masonry cavity wall construction with a flat metal roof will include administrative areas, visitation/training room, waiting area, a day room, and outdoor recreation area. The project also will include fire suppression system, all utilities, communications, site improvements, and associated support facilities. The facility will be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used were cost effective. The facility will be designed as permanent construction in accordance with Unified Facilities Criteria 1-200-01, General Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facilities Criteria 1-200-02, High Performance and Sustainable Building Requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01.
Update #2 ·
** Amendment 0001 to solicitation W9123823R0047 provides updated site visit information under FAR provision 52.236-27 (Alternate I) ** The contractor shall provide a single story, Level I Regional Confinement Facility addition to Building 408, Security Forces Operations Center to accommodate a four-cell requirement in accordance with Air Force Instruction 31-205 Air Force Corrections System. The masonry cavity wall construction with a flat metal roof will include administrative areas, visitation/training room, waiting area, a day room, and outdoor recreation area. The project also will include fire suppression system, all utilities, communications, site improvements, and associated support facilities. The facility will be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used were cost effective. The facility will be designed as permanent construction in accordance with Unified Facilities Criteria 1-200-01, General Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facilities Criteria 1-200-02, High Performance and Sustainable Building Requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01.
Update #1 ·
The contractor shall provide a single story, Level I Regional Confinement Facility addition to Building 408, Security Forces Operations Center to accommodate a four-cell requirement in accordance with Air Force Instruction 31-205 Air Force Corrections System. The masonry cavitywall construction with a flat metal roof will include administrative areas, visitation/training room, waiting area, a day room, and outdoor recreation area. The project also will include fire suppression system, all utilities, communications, site improvements, and associated supportfacilities. The facility will be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used were cost effective. The facility will be designed as permanent construction in accordance withUnified Facilities Criteria 1-200-01, General Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facilities Criteria 1-200-02, HighPerformance and Sustainable Building Requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01.
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| USACE SPK DBB Construction - Project Description – Level I Confinement Facility - Hill AFB, UT | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| F-35 Composite Repair and Training Facility / F-35 Maintenance Facility, Hill Air Force Base, Utah | ENDIST Sacramento | No set-aside | |
| SABER V Hill AFB | Air Force Sustainment Center | Competitive 8(a) | |
| HAFB Multiple Award Construction Contract V (MACC V) | Air Force Sustainment Center | Total Small Business | |
| WWYK260004 - repair structural integrity, B1134, post 34 & north wall | Air Force Sustainment Center | Total Small Business | |
| Office Furniture Bldg. 2213 | Air Force Sustainment Center | No set-aside |