Generator Controller repair
Closed Solicitation Posted
- Solicitation number
- 60100PR240000241
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- Local Area Set-Aside
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- New London, Connecticut 06320, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The United States Coast Guard Academy seeks generator controller repair services through competitive solicitation number 60100PR240000241. The contractor shall remove and replace the controller on a 500KW Kohler generator located at the Academy's New London, Connecticut facility by July 2024. The contractor must furnish all labor, materials, equipment, and transportation necessary to replace the defective Dec 4000 controller with an improved APM-403 controller, program it, and perform an inspection to verify proper operation. Proposals are due by March 5, 2024, with award anticipated by the end of the fiscal year.
This local area set-aside opportunity is designated under NAICS code 811198 and PSC code R499. Interested small businesses located within 50 miles of New London must have experience servicing heavy-duty generators. The place of performance is the Coast Guard Academy campus. The current generator maintenance contractor may also bid on this requirement estimated at $50,000 for a one-time repair to be completed by the start of the next academic year.
Notice text
Kohler 500KW Generator removal and replacement of controller Serial Number 10006147
The contractor shall furnish all labor, material, equipment, transportation, and supervision to replace the generator Controller at the United States Coast Guard Academy, New London, CT.
Place unit in off, disconnect starting battery. Remove all associated wiring on defective controller. Remove and replace defective / obsolete controller (Dec 4000). Land all input and output connections onto new improved controller (APM-403). Program controller with run hrs. and other information needed. Reconnect battery. Run and test unit to verify proper operation.
SEE ATTACHED STATEMENT OF WORK
Files
| File | Type | Posted |
|---|---|---|
| controller repair SOW.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Control, generator, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| Actuator, governor | Coast Guard | No set-aside | |
| Generator, alternati, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| Controller, logic, in repair/modification of | Naval Supply Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity