Fire Suppression Backflow preventer

Closed Pre-Solicitation Posted

Solicitation number
PANNGB26P0000038507
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
McConnell AFB, Kansas 67221, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Kansas Air National Guard at McConnell Air Force Base intends to solicit removal and installation of five backflow preventer systems, and is conducting a sources sought market research announcement with a response due date of July 20, 2026. The procurement is set aside for total small business.

Work is performed at McConnell Air Force Base, Kansas, across multiple buildings. The scope includes removal of existing backflow preventer systems of varying sizes and installation of five new replacement systems: a 6-inch diameter fire suppression backflow preventer in Building 33 (Southwest Bay), a 4-inch diameter fire suppression and double check valve system in Building 44 (Room 122, South wall), and three additional systems at other facility locations. The contractor must perform all removal, proper sizing, connections, installation, testing, and certification with zero defects and no leaks upon completion.

All newly installed systems must be tested and certified by a certified installer meeting requirements established by the Board of Appeals of Plumbers and Gas Fitters of the City of Wichita and Sedgwick County. Upon system certification, the contractor must provide the 184 CES/CEO (Civil Engineer Squadron/Chief of Engineering Operations) with installation date, manufacturer information, model number, serial number, rebuild kit specifications, and system description for each unit.

Responding firms must provide SAM registration details, CAGE code, DUNS number, socio-economic status, and bonding capability (both individual project and aggregate). This is a market research announcement only; the formal solicitation will follow.

Notice text

This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.

Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following: 

  1. Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression 
    1. Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System. 
    2. Install a new 6-inch diameter Fire Suppression Backflow Prevention System. 
    3. Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. 
    4. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: 
      1. Backflow Prevention System’s Installation Date 
      2. Backflow Prevention System’s Manufacture 
      3. Backflow Prevention System’s Model 
      4. Backflow Prevention System’s Serial Number 
      5. Backflow Prevention System’s Rebuild Kit Specifications 
      6. Backflow Prevention System’s Description 
  2. Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve 
    1. Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. 
    2. Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. 
    3. Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. 
    4. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: 
      1. Backflow Prevention System’s Installation Date 
      2. Backflow Prevention System’s Manufacture 
      3. Backflow Prevention System’s Model 
      4. Backflow Prevention System’s Serial Number 
      5. Backflow Prevention System’s Rebuild Kit Specifications 
      6. Backflow Prevention System’s Description 
  3. Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup 
    1. Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System. 
    2. Install a new 1-inch diameter Boiler Makeup Backflow Prevention System. 
    3. Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. 
    4. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: 
      1. Backflow Prevention System’s Installation Date 
      2. Backflow Prevention System’s Manufacture 
      3. Backflow Prevention System’s Model 
      4. Backflow Prevention System’s Serial Number 
      5. Backflow Prevention System’s Rebuild Kit Specifications 
      6. Backflow Prevention System’s Description 
  4. Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression 
    1. Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System. 
    2. Install a new 4-inch diameter Fire Suppression Backflow Prevention System. 
    3. Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. 
    4. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: 
      1. Backflow Prevention System’s Installation Date 
      2. Backflow Prevention System’s Manufacture 
      3. Backflow Prevention System’s Model 
      4. Backflow Prevention System’s Serial Number 
      5. Backflow Prevention System’s Rebuild Kit Specifications 
      6. Backflow Prevention System’s Description 
  5. Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water 
    1. Remove the existing 2.5-inch diameter domestic water Backflow Prevention System. 
    2. Install a new 2.5-inch diameter domestic water Backflow Prevention System. 
    3. Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. 
    4. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: 
      1. Backflow Prevention System’s Installation Date 
      2. Backflow Prevention System’s Manufacture 
      3. Backflow Prevention System’s Model 
      4. Backflow Prevention System’s Serial Number 
      5. Backflow Prevention System’s Rebuild Kit Specifications 
      6. Backflow Prevention System’s Description 

For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.

Attachments:

1. Statement of Work

2. Sources Sought Response Form

Files

File Type Posted
STATEMENT OF WORK.docx DOCX document
Sources Sought Response Form - Fire Suppression Backflow Preventer.pdf PDF