6525--Small Animal High Frequency Ultrasound

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest special notice from .

Solicitation number
36C24624Q0851
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Richmond VA Medical Center Richmond, Virginia 23249, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Network Contracting Office 6 on behalf of the Richmond VAMC is conducting market research through this sources sought notice to identify qualified businesses capable of providing a Small Animal Ultrasound Vevo F2 (Brand Name or Equal) system. The required system must have the capability to capture, store, and analyze precise 3-D and 4-D images of small and larger animal species, with functions to monitor physiological data, perform imaging and analysis, and export data. The system must also have an integrated anesthesia system. Respondents must provide information on their business status, contracting preferences, related companies, certifications, and a capabilities statement. Responses are due by June 14, 2024 at 10:00 AM EST and should be submitted to the specified point of contact.

This pre-solicitation notice does not use any set-asides. The government will use the responses to assist in planning the acquisition strategy, but will not entertain any questions about this market research. No potential incumbents or current contractors are named, and the notice does not provide any award value or budget range details.

Notice text

The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Richmond VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses, capable of providing Small Animal Ultrasound Vevo F2 (Brand Name or Equal) that meet the following:

Functions to be performed.

This portable ultrasound needs to be capable of capturing, storing, and analyzing precise 3-D and 4-D images in small (mice, rats and rabbits) and larger (pigs, sheep) animal species as it relates to general anatomical features (to include echocardiographic data collection and analysis), functional, physiological and molecular data simultaneously, in real time. Due to its capability to image such a small species, this system must also have a compatible anesthesia system.

Performance required, or characteristics.

Monitoring of physiological functions in real time

Heart rate (EKG wave forms and beats per minute)

Body temperature (Celsius and Fahrenheit)

Respiration rate (breathes per minute)

Blood pressure catheter option

Integrated heated anesthesia (isoflurane) maintenance system.

Imaging capturing capabilities

In vivo image resolution/quality needed: >65Hz.

Image view types needed: M-mode, color doppler, tissue doppler, doppler imaging.

Imaging mode capabilities: M-mode, color doppler, tissue doppler, doppler imaging, ECG trigger analysis

Image-guided injection tools for specialized for small animals.

Doppler capabilities: tissue, color and pulse wave doppler imaging

ECG triggering and respiratory gating to correct for imaging artifacts.

Ability to create 3-D renderings and make volumetric measurements.

4-D imaging that allows for visualization of cardiac dynamics and geometry, over one complete cardiac cycle

Frame rate frequency bandwidth: 1-70Hz

Frames per second: 300-400

Ultra-high frequency ultrasound with high temporal resolution transducers

Compatible high and low frequency transducers that can be used on species ranging from mice to pigs (50-3 MHz)

Transducer with broadband frequency linear micro-array of 46MHz-20MHz for smaller species

Transducer with broadband frequency micro-array of 6.5MHz for large animal species

Image analysis capabilities

Integrated Left Ventricle (LV) trace analysis tools that can generate calculations for cardiac function such as output, stroke volume and ejection fraction).

Graphical tools that enable custom configuration of heart wave forms, pulse sequences and delay profiles on transmit.

Predetermined small animal-based measurements and calculations.

Contrast mode tools that can be used for data quantification.

Imaging data export and storage

Data image file export format: DICOM, tif, gif, png, csv

Data video export format: .avi and .mp4

Data transfer can be manually done and does not require wireless transfer.

Large data storage of at least 2TB SSD

Essential physical characteristics; Dimensions (if applicable)

Portability so that it can be mobilized between rooms as needed, by one person.

Locking system for portability function.

Two monitors for image display/review and image acquisition adjustments.

Imaging station specifically for small animal handling, positioning, and imaging optimization.

Integrate anesthesia system needs to use isoflurane vaporizer, have a scavenging system, and regulator, and an oxygen flow meter.

Complete system must be made of material that can be easily sanitized between animals.

Minimum of 2 transducer ports for the ultrasound system.

USB Connectivity for data export

Must arrive full assembled and offer in person training.

All respondents shall indicate/provide the following:

Whether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.

Is your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?

Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes.

Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.

Whether or not your company has an active SAM registration and the companies Unique Entity Identifier.

A copy of its capabilities statement.

Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.

If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable.

The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than June 14, 2024, 10:00AM EST to the attention of: Cedric.frasier@va.gov

Please title the subject line for all responses as: Small Animal Ultrasound: 36C24624Q0851.

Files

File Type Posted
36C24624Q0851.docx DOCX document

Notice history

Notice Type Posted
6525--Animal High Frequency Ultra Sound Award Award Notice
6525--Small Animal High Frequency Ultra Sound Research Service (VA-24-00050865) Latest special notice Special Notice
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
DA10--HTM PO MED TECH - Tech Stdz Priority - Enterprise Point of Care Ultrasound PACS (VA-27-00007275) NAICS 513210 VA Technology Acquisition Center No set-aside
Q522--Sources Sought | Ultrasound Guidance for Urology | Orlando Orlando VA Medical Center and Lake Baldwin Outpatient Clinic Orlando, Florida 32803, United States · NAICS 621512 Veterans Integrated Service Network 8 No set-aside
J065--Imaging Service & Preventative Maintenance EHCC & MTV Evansville Health Care Center Evanville, Indiana 47715, United States · NAICS 811210 Veterans Integrated Service Network 15 No set-aside
J065--Preventative Maintenance for Hydropac AWS 2500 Pouch Machine NAICS 811210 Veterans Integrated Service Network 4 No set-aside
6640--Capillary Electrophoresis NAICS 334516 Veterans Integrated Service Network 6 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity