3-Phase Step Down Transformer

Closed Solicitation Posted

Solicitation number
N0024426Q0094
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Monterey, California 93943, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Navy Naval Supply Systems Command seeks one custom-built, marine-grade 3-phase step-down transformer, 27 kVA or higher, for use aboard civilian research vessels, with quotation due September 8 and questions due September 6, 2026. This procurement is set aside for Women-Owned Small Businesses (WOSB) at 100 percent, foreclosing competition outside that pool.

Place of performance is Monterey, California. The transformer must convert 480 VAC 3-phase 50-ampere input (with accommodation for 440 and 460 VAC) to three simultaneous outputs: two 115 VAC 3-phase 30-ampere circuits and one 115 VAC single-phase 30-ampere circuit. Mandatory compliance with MIL-T-15108C is required. The unit must feature EMI shielding, copper windings at approximately 3% impedance, NEMA 4 marine-grade enclosure rated for 50 degrees Celsius ambient temperature with 115-degree Celsius temperature rise and 200-degree Celsius insulation rating, removable locking casters, lifting eyes, and reinforcement for crane or forklift handling. Grounding must be open-delta with bonded primary and secondary, including direct hull bonding via a 4th pin on the input connector and 2-foot backup braid. The unit must mount to UNOLS deck pattern specifications (2-foot by 2-foot center spacing for 1-inch 8-bolt holes). Wiring must use 6 AWG SIL-A-BLEND 200C/1000V for input and 8 AWG SIL-A-BLEND 200C/1000V for output, with MS17344 and MS17346 connector compatibility. Delivery is required by May 31, 2027. The NAICS code is 335311, Power, Distribution, and Specialty Transformer Manufacturing. Award will be made on a Lowest Price Technically Acceptable (LPTA) basis. Quoters must provide comprehensive technical documentation demonstrating compliance with all mandatory requirements.

Notice text

The Government requires one (1) custom-built, marine-grade, 3-phase step-down transformer, 27 kVA or higher, for use with a Naval Conex box aboard civilian research vessels. The transformer shall meet specified electrical, environmental, grounding, and mechanical requirements, including mandatory compliance with MIL-T-15108C. The Solicitation and Attachment 1- Salient Characteristics, are attached to this notice and provide the complete requirement, quotation instructions, and evaluation criteria.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Transformer, power NAICS 334416 Land and Maritime Woman-Owned Small Business
Transformer, power, in repair/modification of NAICS 335311 Naval Supply Systems Command No set-aside
PRM/AAU/CHI PWA, AI, in repair/modification of NAICS 335311 Naval Supply Systems Command No set-aside
Transformer, power NAICS 333992 Land and Maritime Total Small Business
Transformer, power NAICS 334413 Land and Maritime Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity