Y25-756-GV_Final_drawings_.pdf
PDF 7 MB Posted
- Attached to
- Beach Boulevard Drainage Improvements
- Solicitation number
- Y25-756
- Issued by
- Orange County, Orlando City, Florida
About this file
These construction plans detail the Beach Boulevard Drainage Improvements project for Orange County, Florida, prepared by Pegasus Engineering, LLC and dated July 2024. The project involves drainage infrastructure modifications along Beach Boulevard, focusing on improvements to storm drainage systems, including installing new drainage inlets, storm pipes, concrete aprons, and pavement restoration. The project area spans multiple parcels in Orange County, with specific locations identified near Lake Baldwin Lane. The plans include detailed design specifications, topographic surveys, pollution control measures, and drainage structure details across 11 technical sheets.
The estimated project cost is $163,100.00, with sealed bids to be electronically submitted through the OpenGov e-Procurement Platform by 4:00 pm EST on Tuesday, April 29, 2025. Key project elements include roadway open cut operations, asphalt milling, concrete sidewalk installation, driveway modifications, and drainage structure connections. The project will require careful management of existing utilities, landscaping, and environmental controls, with specific attention to erosion prevention and stormwater management. The technical drawings provide comprehensive details on construction methods, material specifications, and specific installation requirements for drainage infrastructure improvements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LAKE
DRUID
CAY DEE
LAKE SHANNON
LAKE
CORRINE DRIVE
MAGUIRE BOULEVARD
PARK
AUDUBON
PARK
BALDWINW
IN
TE
R P
A R
K D
R
IV
E
B
EN
N
ET
T R
O A
D
GEAR
LAKE
EAST COLONIAL DRIVE
SUSANNAH
LAKE
BALDWIN
LAKE
BARTON
LAKE
LITTLE
LAKE
BARTON
SO
U
TH
S
EM
O
R A
N B
O U
LE
V
A R
D
UNDERHILL
LAKE
BEACHLINE EXPRESSWAY
SQUARE
FASHION
ORLANDO
AIRPORT
EXECUTIVE
ORLANDO
REVISIONS AND SUBMITTAL HISTORY
DATE:
DATE:
DATE:
DATE:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
APPROVED BY:
SHEET
OF
DATE BY
PREPARED BY
09 / 08 / 20231. 90% SUBMITTAL - ORANGE COUNTY REVIEW GAT
01 / 24 / 20242. 100% SUBMITTAL - SAI REVIEW GAT
INDEX OF SHEETS
LOCATION MAP
UTILITIES ENCOUNTERED
SECTION TOWNSHIP RANGE21 22S 30E
SECTION TOWNSHIP RANGE- - - - - -
COVER SHEET
SHEET
TOPOGRPAHIC SURVEY4
310 WEST STATE ROAD 434, SUITE 309
WINTER SPRINGS, FLORIDA 32708
PHONE: 407-992-9160
FAX: 407-358-5155
State of Florida Board of Professional Engineers Certificate of Authorization No. 27770
GAT
GAT
GAT
GAT
PROJECT NO: SAI-22004
07 / 2024 07 / 2024 07 / 2024 07 / 2024
BOARD OF COUNTY COMMISSIONERS
JERRY L. DEMMINGS
CHRISTINE MOORE
MAYRA URIBE
MARIBEL GOMEZ CORDERO
EMILY BONILLA
MICHAEL 'MIKE" SCOTT
COUNTY MAYOR
DISTRICT 2
DISTRICT 3
DISTRICT 4
DISTRICT 5
DISTRICT 6
NICOLE H. WILSON DISTRICT 1
DATE: ENGINEER: REG. NO.
CERTIFICATION TO PLANS
I HEREBY CERTIFY THAT THE DESIGN FOR THIS PROJECT AND THE ATTACHED CONSTRUCTION PLANS COMPLY WITH THE REQUIREMENTS OF SECTION 336.045 OF THE FLORIDA STATUTES AND ARE IN SUBSTANTIAL CONFORMANCE WITH THE STANDARDS CONTAINED IN THE EDITION OF THE "MANUAL OF UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION AND MAINTENANCE FOR STREETS AND HIGHWAYS" IN EFFECT ON THIS DATE AS ADOPTED BY THE FLORIDA DEPARTMENT OF TRANSPORTATION PURSUANT TO SUBSECTION 336.045(1) OF THE FLORIDA STATUTES.
CHANGED CONDITIONS
PLANS WERE PREPARED ACCORDING TO AVAILABLE INFORMATION TO ADEQUATELY ADDRESS CONDITIONS AS THEY EXISTED AT THE TIME OF PLANS PREPARATION. NEEDS, CONDITIONS AND OWNERSHIP OF PROPERTIES MAY HAVE CHANGED SINCE PROJECT DESIGN. THE COUNTY'S REPRESENTATIVE WILL ADDRESS CHANGES AND NEEDS WITH THE PROPERTY OWNER OR THEIR REPRESENTATIVES. CONTRACTOR SHALL WORK WITH THE COUNTY'S REPRESENTATIVE IN ADDRESSING AND MEETING NEEDS AND CONDITIONS THAT MAY HAVE CHANGED SINCE PLANS PREPARATION.
GREGORY A. TEAGUE, P.E.
47663JULY 29, 2024
ELEVATION = 105.044 FT, NAVD
SOURCE OF BENCHMARK DATUM
OWNER
ROADS AND DRAINAGE DIVISION
4200 SOUTH JOHN YOUNG PARKWAY
CIVIL ENGINEER (PRIME CONSULTANT)
COMMISSION DISTRICT 5
BEACH BOULEVARD DRAINAGE IMPROVEMENTS
CONSTRUCTION PLANS - FINAL SUBMITTALCONSTRUCTION PLANS - FINAL SUBMITTAL
1" = 1,500'
ORLANDO, FLORIDA 32839
SINGHOFEN & ASSOCIATES
11723 ORPINGTON STREET, SUITE 100
ORLANDO, FL 32817
CIVIL ENGINEER (SUB-CONSULTANT)
PEGASUS ENGINEERING, LLC
301 WEST STATE ROAD 434, SUITE 309
WINTER SPRINGS, FLORIDA 32708
SURVEYOR (SUB-CONSULTANT)
BFA ENVIRONMENTAL CONSULTANTS
1230 HILLCREST STREET
ORLANDO, FL 32803
PROJECT TEAM
NOTES
1. GOVERNING SPECIFICATIONS: STATE OF FLORIDA, DEPARTMENT OF
TRANSPORTATION, STANDARD SPECIFICATIONS (LATEST EDITION) AND
SUPPLEMENTS THERETO IF NOTED IN THE BID DOCUMENTS FOR THIS PROJECT.
2. ATTENTION IS DIRECTED TO THE FACT THAT THESE PLANS MAY HAVE BEEN
CHANGED IN SIZE BY REPRODUCTION. THIS MUST BE CONSIDERED WHEN
OBTAINING SCALED DATA.
22" X 34" DRAWINGS ~ TO SCALE
12" X 18" DRAWINGS ~ HALF SIZE
11" X 17" DRAWINGS ~ NOT TO SCALE
3. ELEVATION INFORMATION SHOWN WITHIN THESE PLANS IS REFERENCED TO
THE NAVD88 VERTICAL DATUM.
4. DATUM SHIFT FOR THIS PROJECT (SEE PROJECT LOCATION SUMMARY THIS
SHEET) WILL BE APPLIED AS A CONSTANT VALUE FOR CONVERTING ELEVATIONS
BETWEEN THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) AND THE
NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD29).
COMPUTED DATUM SHIFTS
NAVD88 + 0.965' = NGVD29
NGVD29 - 0.965' = NAVD88
DESCRIPTION
GENERAL NOTES2 - 3
PLAN AND PROFILE - BEACH BOULEVARD5
POLLUTION CONTROLS8
SEE SHEET 3
THIS CERTIFICATION EXCLUDES CERTAIN INFORMATION THAT WAS PREPARED "BY OTHERS" AND MAY BE INCLUDED IN THE PLANS FOR THE CONTRACTOR'S CONVENIENCE, INCLUDING BUT NOT LIMITED TO THE TOPOGRAPHIC SURVEYS, SOIL BORING PROFILES, MANUFACTURER DETAILS, FDOT DETAILS OBTAINED FROM THE DESIGN STANDARDS, AND
STANDARD DETAILS PROVIDED BY ORANGE COUNTY.
ORANGE COUNTY PUBLIC WORKS
JOSPEH C. KUNKEL, P.E. DIRECTOR OF PUBLIC WORKS
407-836-7900
407-679-3001
407-992-9160
407-896-8608
PROJECT #_______
04 / 02 / 20243. 100% SUBMITTAL - ORANGE COUNTY REVIEW #1 GAT
LATITUDE 28.5587°
PROJECT LOCATION
LONGITUDE -81.3250°
LOCATION
PROJECT
ORANGE COUNTY PUBLIC WORKS
ORANGE COUNTY BENCHMARK #2
11-011 ALUMINUM DISC
ELEVATION = 108.078 FT, NAVD
ORANGE COUNTY BENCHMARK #1
BM 11-012 ALUMINUM DISC
ELIZABETH WHITE ROADS & DRAINAGE DIVISION
TEMPORARY EROSION CONTROL DETAILS9
DRAINAGE STRUCTURE DETAILS10
MISCELLANEOUS DETAILS11
BARNES, FERLAND AND ASSOCIATES
4. 100% SUBMITTAL - ORANGE COUNTY REVIEW #2
SEE THE GENERAL NOTES
FOR THIS INFORMATION
N 1536278.85, E 551184.81 N 1537130.07, E 550787.88
LAT 28.5595°, LONG -81.3270°
NORTH OF BEACH BOULEVARD
WEST SIDE OF LAKE BALDWIN LANE
LAT 28.5619°, LONG -081.3283°
NORTH OF BURKE STREET
WEST SIDE OF LAKE BALDWIN LANE
GRADING AND DRAINAGE PLAN - BEACH BOULEVARD6
05 / 01 / 2024 GAT
PAVEMENT RESTORATION PLAN - BEACH BOULEVARD7
5. FINAL SUBMITTAL - DELIVERABLES 07 / 29 / 2024 GAT
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH AND CONFORM TO THE MOST STRINGENT REQUIREMENT OF THE PROJECT SPECIFICATIONS, THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (FY 2024-25) AND SUPPLEMENTS THERETO, ORANGE COUNTY ROAD CONSTRUCTION SPECIFICATIONS, AND ORANGE COUNTY MANUAL OF
STANDARDS AND SPECIFICATIONS FOR WASTEWATER AND WATER MAIN CONSTRUCTION.
2. ENGINEER OR INSPECTOR AS REFERENCED IN THESE GENERAL NOTES AND DRAWINGS SHALL BE DEFINED AS "PROJECT MANAGER" IN THE
CONTRACT.
3. THE CONTRACTOR SHALL HAVE ALL REQUIRED PERMITS IN-HAND, INCLUDING A CONSUMPTIVE USE PERMIT, PRIOR TO BEGINNING CONSTRUCTION, AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE REQUIREMENTS OF THE VARIOUS PERMITS INCLUDED IN THE CONTRACT DOCUMENTS AND THOSE OBTAINED BY THE CONTRACTOR. PAYMENT IS INCLUDED IN THE BID PRICE FOR ITEM NO. 104-0-1
"PREVENTION, CONTROL, AND ABATEMENT OF EROSION AND WATER POLLUTION".
4. AT LEAST THREE CALENDAR DAYS PRIOR TO THE PRE-CONSTRUCTION CONFERENCE; THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A TENTATIVE BASE CONSTRUCTION SCHEDULE, A PRE-CONSTRUCTION SURVEY, A TRAFFIC CONTROL PLAN, AND A SEDIMENT AND EROSION CONTROL PLAN. NO WORK SHALL BEGIN PRIOR TO APPROVAL OF THE CONSTRUCTION SCHEDULE, PRE-CONSTRUCTION SURVEY, TRAFFIC CONTROL PLAN, AND SEDIMENT AND EROSION CONTROL PLAN.
5. PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SET OF FIELD NOTES VERIFYING THE BENCHMARK ELEVATIONS AND REFERENCE POINT TIES SHOWN ON THE PLANS, AND/OR A SET OF FIELD NOTES WITH THE LOCATION, DESCRIPTION AND ELEVATION OF ALL ADDITIONAL BENCHMARK AND REFERENCE POINT TIES PROPOSED TO BE USED IN CONSTRUCTING THE PROJECT. ALL SUBMITTALS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL SURVEYOR AND MAPPER REGISTERED IN THE STATE OF FLORIDA. PAYMENT SHALL BE INCLUDED IN THE BID PRICCE FOR ITEM NO. 101-1 "MOBILIZATION".
6. BFA ENVIRONMENTAL CONSULTANTS (aka, BARNES, FERLAND AND ASSOCIATES, INC.) PROVIDED TOPOGRAPHY, BENCHMARKS, AND
RIGHTS-OF-WAY INFORMATION.
7. WITHIN 14 CALENDAR DAYS AFTER NOTICE TO PROCEED, THE CONTRACTOR SHALL STAKE THE RIGHTS-OF-WAY AT 100' INTERVALS AND AT RIGHT-OF-WAY BREAKS WITH STATIONING SHOWN ON THE STAKES. NO INVOICE FOR PAYMENT WILL BE PROCESSED UNTIL THE RIGHT-OF-WAY HAS BEEN STAKED TO THE SATISFACTION OF THE ENGINEER. THIS STATIONING WILL REMAIN UNTIL THE END OF ALL CONSTRUCTION ACTIVITIES. PAYMENT IS INCLUDED IN THE PRICE BID FOR ITEM NO. 101-1 "MOBILIZATION".
8. ALL PROPERTY CORNERS AND MONUMENTS SHOWN ON THE PLANS OR FOUND DURING CONSTRUCTION SHALL BE PRESERVED. IF A PROPERTY CORNER OR MONUMENT IS IN DANGER OF BEING DESTROYED OR DISTURBED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER WITHOUT DELAY AND SHALL PROVIDE WRITTEN FOLLOW UP CONFIRMATION WITHIN 48 HOURS OF NOTIFICATION.
9. ANY USCGS MONUMENT WITHIN THE LIMITS OF CONSTRUCTION SHALL BE PROTECTED. IF IN DANGER OF DAMAGE, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE PROJECT ENGINEER, ORANGE COUNTY SURVEY SECTION 407-836-7940, AND BOTH SHALL NOTIFY:
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
BUREAU OF SURVEY AND MAPPING
3900 COMMONWEALTH BLVD.
TALLAHASSEE, FLORIDA 32399-3000
850-245-2118 public.services@dep.state.fl.us
10. SUBSURFACE INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FOR USE IN ESTABLISHING DESIGN CRITERIA FOR THE PROJECT.
THIS INFORMATION MAY NOT ACCURATELY REFLECT ACTUAL SOIL CONDITIONS AS TO THE DEPTH, EXTENT, OR CHARACTER OF THE MATERIAL TO BE ENCOUNTERED IN CONSTRUCTION OF THE PROJECT AND IS NOT TO BE CONSTRUED AS PART OF THE PLANS GOVERNING CONSTRUCTION OF THE PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INQUIRE OF THE ENGINEER IF ADDITIONAL INFORMATION IS AVAILABLE, TO MAKE ARRANGEMENTS TO REVIEW SAME PRIOR TO BIDDING, AND TO MAKE HIS OWN DETERMINATION AS
TO ALL SUBSURFACE CONDITIONS.
11. THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES IS BASED ON INFORMATION PROVIDED BY THE UTILITY OWNERS, AVAILABLE RECORDS, AND SURVEYED FIELD INFORMATION. THE INFORMATION MAY NOT REFLECT ACTUAL CONDITIONS OR BE ALL INCLUSIVE REGARDING ALL UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED, OR THAT THE UTILITIES ARE IN THE HORIZONTAL OR VERTICAL LOCATIONS SHOWN. THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION OF UTILITIES AS NECESSARY TO ESTABLISH THEIR LOCATIONS AND AVOID DAMAGE. DAMAGE TO EXISTING UTILITIES AS A RESULT OF THE CONTRACTOR'S WORK OR HIS SUBCONTRACTORS SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR, PAY ALL FINES, PAY ALL FEES, AND ALL OTHER COST ASSOCIATED WITH RESTORING THE UTILITY. THE CONTRACTOR MUST NOTIFY SUNSHINE 811 (fka, SUNSHINE STATE ONE-CALL) AT LEAST 5 DAYS PRIOR TO CONSTRUCTION. SUNSHINE 811 DESIGN TICKET WAS OBTAINED
ON AUGUST 29, 2023.
12. PRIOR TO ANY SCHEDULED INTERRUPTION OF UTILITY SERVICE, THE CONTRACTOR SHALL COORDINATE SUCH INTERRUPTION WITH THE UTILITY PROVIDER AND SHALL PROVIDE A MINIMUM 24-HOUR NOTICE TO THE AFFECTED PARTIES. IN THE CASE OF A WATER MAIN SHUT DOWN, A MINIMUM 24-HOUR NOTICE ALSO SHALL BE PROVIDED TO THE FIRE DEPARTMENT. THE CONTRACTOR SHALL NOTIFY THE GAS UTILITY A MINIMUM OF TWO (2) WORKING DAYS PRIOR TO EXCAVATION, AS REQUIRED BY CHAPTER 77-153 OF THE FLORIDA STATUTES.
13. THE CONTRACTOR IS REQUIRED TO COORDINATE CLOSELY WITH THE UTILITY COMPANIES WHEN CONNECTING TO OR WORKING AROUND EXISTING FACILITIES. PROTECT ANY UTILITIES ENCOUNTERED. IF AN EXISTING UTILITY MUST BE RELOCATED DUE TO A CONFLICT, NOTIFY UTILITY COMPANY AND ENGINEER. ALL COORDINATION AND SCHEDULING OF UTILITY CROSSINGS AND RELOCATIONS SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
14. THE LIMITS OF CONSTRUCTION ARE DEFINED AS ROADWAY RIGHTS-OF-WAY, PERMANENT DRAINAGE AND/OR UTILITY EASEMENTS, AND
TEMPORARY CONSTRUCTION EASEMENTS.
15. THE CONTRACTOR SHALL BE ENTIRELY RESPONSIBLE AND LIABLE FOR ALL DAMAGE OR INJURY AS A RESULT OF HIS OPERATIONS TO ALL OTHER ADJACENT PUBLIC AND PRIVATE PROPERTY, LANDSCAPING, TREES, FENCES, UTILITIES, STRUCTURES OF ANY KIND AND
APPURTENANCES DURING THE PROGRESS OF THE WORK.
16. ALL AREAS WHERE SOD HAS BEEN REMOVED OR DISTURBED BY CONTRACTOR'S OPERATIONS SHALL BE SODDED OF LIKE KIND. PAYMENT INCLUDED IN THE UNIT PRICE FOR ITEM NO. 570-1-2 “PERFORMANCE TURF (SOD, MATCH EXISTING)”.
17. WHERE THE REQUIRED MINIMUM SEPARATION BETWEEN UTILITIES IS SPECIFIED, THE DISTANCE SHALL BE MEASURED FROM OUTSIDE OF
PIPE TO OUTSIDE OF PIPE.
18. ALL UTILITIES ARE TO BE ADJUSTED OR RELOCATED BY OTHERS, UNLESS NOTED OTHERWISE ON THE DRAWINGS OR DIRECTED BY THE
ENGINEER.
19. EXISTING TRAFFIC SIGNS AND PAVEMENT MARKINGS IN CONFLICT WITH CONSTRUCTION SHALL BE REMOVED AND REPLACED AS DIRECTED BY THE ENGINEER. PAYMENT INCLUDED IN THE UNIT PRICE FOR ITEM NO. 102-1 “MAINTENANCE OF TRAFFIC”.
20. MAILBOXES IN CONFLICT WITH CONSTRUCTION SHALL BE RELOCATED IN ACCORDANCE WITH FDOT INDEX 110-200 AND AS APPROVED BY THE ENGINEER. ALL COSTS SHALL BE INCLUDED IN THE UNIT PRICE OF THE PAY ITEM FOR ITEM NO. 110-1-1 “CLEARING AND GRUBBING”.
21. EXISTING PAVEMENT SHALL BE SAW CUT AS REQUIRED FOR CONSTRUCTION. ALL COSTS SHALL BE INCLUDED IN THE UNIT PRICE OF THE PAY
ITEM NO. 110-4-10 “REMOVAL OF EXISTING CONCRETE”.
ITEM NO. 110-4-10 “REMOVAL OF EXISTING CONCRETE”.
22. ALL EXISTING FENCES THAT ARE REMOVED ARE TO BE REPLACED OR RELOCATED. ALL FENCES DAMAGED BY CONSTRUCTION ACTIVITIES ARE TO BE REPLACED WITH NEW FENCING OF THE SAME TYPE AND MATERIAL. ALL COSTS SHALL BE INCLUDED IN THE UNIT PRICE FOR ITEM NO.
110-1-1 “CLEARING AND GRUBBING”, UNLESS NOTED OTHERWISE.
23. THE CONTRACTOR SHALL COMPLY WITH THE DEPARTMENT OF LABOR, SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (PL 91-596) AND UNDER SECTION 107 OF THE CONTRACT
WORK HOURS AND SAFETY STANDARDS ACT (PL 91-54).
24. NO BURNING SHALL BE DONE EXCEPT UPON APPROVAL BY THE JURISDICTIONAL MUNICIPALITY.
25. THE DISPOSAL OF EXCESS EARTHWORK MATERIALS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. APPROVAL OF DISPOSAL SITES SHALL BE OBTAINED FROM ORANGE COUNTY PRIOR TO DISPOSAL. ALL EXCESS MATERIAL IS THE PROPERTY OF THE CONTRACTOR.
26. NO TRENCHES SHALL BE ALLOWED TO REMAIN OPEN OVERNIGHT.
27. DISTURBED AREAS SHALL BE COMPACTED (AS A MINIMUM) EQUAL TO ADJACENT UNDISTURBED GROUND EXCEPT WHEN OTHERWISE SPECIFIED FOR BEDDING, BACKFILL, OR ROADWAY EMBANKMENT. ALL DISTURBED AREAS ARE TO BE SODDED EXCEPT FOR AREAS THAT ARE
LANDSCAPED OR PAVED.
28. PROPERTIES ADJACENT TO WORK ZONES SHALL BE GRADED TO DRAIN WITHIN THE LIMITS OF CONSTRUCTION AND COMPACTED AND SODDED WITH THE SAME TYPE SOD OR EXISTING, UNLESS OTHERWISE DIRECTED BY THE ENGINEER.
29. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL VALVE BOXES ON GAS AND WATER MAINS WITHIN THE LIMITS OF CONSTRUCTION THAT ARE TO REMAIN IN SERVICE. PRIOR TO COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL ADJUST ALL VALVE BOXES WITHIN CONSTRUCTION AREAS SO THE TOPS ARE FLUSH WITH FINISHED PAVEMENT OR WITH FINISHED GRADE IN UNPAVED AREAS.
30. SERVICE LINES THAT CANNOT BE PROTECTED OR ADJUSTED SHALL BE RELOCATED. PAYMENT IS INCLUDED IN THE PRICE FOR STORM SEWER
PIPE.
31. ALL SIDEWALK CONSTRUCTION SHALL COMPLY WITH THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION.
SUPPLEMENTAL GENERAL NOTES - STORMWATER CONSTRUCTION
1. ALL NEW OR REPLACEMENT CONCRETE PIPES, CULVERTS, AND STORM SEWERS SHALL BE CLASS III REINFORCED CONCRETE, UNLESS NOTED OTHERWISE ON THE DRAWINGS OR BY THE ENGINEER. ALL PIPES SHALL BE CUT FLUSH WITH THE INSIDE OF DRAINAGE STRUCTURES.
2. ALL REINFORCED CONCRETE PIPE SHALL BE INSTALLED USING SELECT MATERIAL FOR THE SOIL ENVELOPE AS SHOWN ON THE STORM DRAINPIPE INSTALLATION DETAIL. BACKFILL AROUND POLYPROPYLENE PIPE SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS.
3. ALL JOINTS OF CONCRETE PIPE CULVERTS AND STORM SEWERS SHALL HAVE A “FILTER FABRIC JACKET” AS DETAILED IN STANDARD PLANS, FDOT INDEX 430-001. PAYMENT FOR FILTER FABRIC OR GEOTEXTILE FABRIC SHALL BE INCLUDED IN THE PAY ITEM FOR PIPE CULVERTS.
4. STEEL GRATES SHALL BE USED FOR ALL DITCH BOTTOM INLETS, UNLESS OTHERWISE SHOWN ON THE PLANS.
5. ALL CURB INLETS, DITCH BOTTOM INLETS, AND MANHOLES SHALL HAVE TRAFFIC BEARING FRAMES AND COVERS OR GRATES MEETING HS-20
LOADING REQUIREMENTS UNLESS OTHERWISE SHOWN ON THE PLANS.
6. ALL GRATES SHALL BE CHAINED AND LOCKED IN ACCORDANCE WITH FDOT STANDARD PLANS, INDEX 425-001. COST OF EYEBOLT AND CHAIN
SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE FOR THE STRUCTURE.
7. ALL MANHOLE COVERS SHALL INCLUDE THE COUNTY'S LOGO AND BE IDENTIFIED AS “ORANGE COUNTY STORM”.
8. CHANGES OF PIPE INVERTS NOT EXCEEDING PLUS OR MINUS 1' WILL NOT BE CONSIDERED AS A BASIS FOR ADDITIONAL COMPENSATION FOR
THE PERTINENT PIPE BID ITEM OR FOR MODIFICATION OF PRECAST STRUCTURES.
9. ALL TYPE J STRUCTURE BOTTOMS SHALL HAVE A MINIMUM 6'-0” WALL HEIGHT WHEN POSSIBLE.
SUPPLEMENTAL GENERAL NOTES - TRAFFIC CONTROL
1. THE TRAFFIC CONTROL PLAN SHALL BE PREPARED BY A PERSON CERTIFIED BY THE FLORIDA DEPARTMENT OF TRANSPORTATION AS HAVING SATISFACTORILY COMPLETED AN FDOT APPROVED WORK ZONE TRAFFIC CONTROL TRAINING COURSE, SIGNED AND SEALED BY AN ENGINEER.
2. THE TRAFFIC CONTROL PLAN SHALL DESCRIBE THE MEASURES TO BE EMPLOYED DURING CONSTRUCTION TO WARN MOTORISTS AND PEDESTRIANS OF HAZARDS, TO ADVISE MOTORISTS OF THE PROPER TRAVEL PATH THROUGH OR AROUND THE WORK AREA, TO DELINEATE AREAS WHERE TRAFFIC SHOULD NOT OPERATE, AND TO SEPARATE AND PROTECT MOTORISTS, PEDESTRIANS, AND THE WORK FORCE DURING ALL PHASES OF THE WORK. THE PLAN SHALL ALSO CONSIDER ACCESS TO BUSINESSES WITHIN THE CONSTRUCTION AREA AND PROVIDE BUSINESS ENTRANCE SIGNS TO ROUTE MOTORISTS TO DESIGNATED PARKING AREAS. THE CONTRACTOR SHALL OBTAIN APPROVAL OF THE TRAFFIC CONTROL PLAN FROM THE COUNTY PRIOR TO BEGINNING CONSTRUCTION. PAYMENT FOR PREPARING AND SUBMITTING THE
TRAFFIC CONTROL PLAN SHALL BE INCLUDED IN ITEM NO. 101-1 "MOBILIZATION".
3. ACCESS TO BUSINESS AND RESIDENTIAL DRIVEWAYS SHALL BE MAINTAINED AT ALL TIMES.
4. NO ROADWAYS SHALL BE CLOSED WITHOUT PRIOR APPROVAL BY THE COUNTY.
5. ALL TRAFFIC CONTROL DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES AND/OR
THE FLORIDA DEPARTMENT OF TRANSPORTATION DESIGN STANDARDS.
6. ALL TRAFFIC CONTROL DEVICES SHALL BE IN PLACE BEFORE THE START OF CONSTRUCTION ON AFFECTED ROADWAYS.
7. WARNING LIGHTS SHALL BE USED ON BARRICADES DURING HOURS OF DARKNESS IN ACCORDANCE WITH FDOT STANDARD PLANS, INDEX 102-600.
8. ALL TRAFFIC CONTROL DEVICES SHALL BE VERIFIED CORRECTLY PLACED AND FUNCTIONING AT THE END OF EACH WORKDAY.
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
G E
N E
R A
L N
O T
E S
ORANGE COUNTY NOTES #1 (22" X 34")
UTILITIES ENCOUNTERED
CHARTER COMMUNICATIONS
CATV
JOHN SMITH
407-532-8520
DUKE ENERGY
ELECTRIC
DUKE'S CUSTOMER SERVICE CENTER
407-629-1010
USIC DISPATCH (ALTERNATE)
800-778-9140
CITY OF WINTER SPRINGS
SEWER, WATER, RECLAIMED WATER
DILLON THOMAS
407-327-1800, #588
CLIFTON MULLIS (EMERGENCY CONTACT)
407-327-1800, #302
AT&T DISTRIBUTION
TELEPHONE
DINO FARRUGGIO
561-683-2729
SUPPLEMENTAL GENERAL NOTES - SEDIMENT AND EROSION CONTROL
1. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE PREVENTION, CONTROL, AND ABATEMENT OF EROSION, WATER POLLUTION, AND THE TRANSPORTATION OF ERODED MATERIALS OFF SITE.
2. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO THE ENGINEER A SEDIMENT AND EROSION CONTROL PLAN. THE SEDIMENT AND EROSION CONTROL PLAN SHALL BE PREPARED IN ACCORDANCE WITH THE "FLORIDA EROSION AND SEDIMENT CONTROL MANUAL" AND SHALL BE SPECIFIC TO THE MEANS, METHODS, AND SEQUENCE OF CONSTRUCTION TO BE EMPLOYED BY THE CONTRACTOR AND SHALL IDENTIFY THE TYPES AND LOCATIONS OF CONTROLS THAT ARE TO BE IMPLEMENTED DURING EACH PHASE OF CONSTRUCTION AS SHOWN ON THE APPROVED CONSTRUCTION SCHEDULE TO MINIMIZE EROSION, PREVENT THE TRANSFER OF ERODED MATERIALS ONTO ANY OFF SITE PARCEL OR INTO ANY RECEIVING WATER, AND PREVENT VIOLATING STATE AND/OR FEDERAL PERMIT REQUIREMENTS. PAYMENT FOR PREPARING AND SUBMITTING THE SEDIMENT AND EROSION CONTROL PLAN AND FOR ANY MODIFICATIONS TO THE SEDIMENT AND EROSION CONTROL PLAN DURING CONSTRUCTION WILL BE INCLUDED IN ITEM NO. 101-1 "MOBILIZATION". THE SEDIMENT AND EROSION CONTROL PLAN SHALL DESCRIBE BUT NOT BE LIMITED TO THE FOLLOWING ITEMS FOR EACH PHASE OF CONSTRUCTION OPERATIONS OR ACTIVITIES:
A. TYPES AND LOCATIONS OF ALL EROSION CONTROL DEVICES
B. ESTIMATED TIME EROSION CONTROL DEVICES WILL BE IN OPERATION
C. METHODS FOR CONTAINMENT OR REMOVAL OF ERODED MATERIALS FROM DISCHARGES RELATED TO DEWATERING OPERATIONS
D. METHODS FOR CONTAINMENT OR REMOVAL OF POLLUTANTS OR HAZARDOUS WASTES
E. METHODS FOR MAINTENANCE OF EROSION CONTROL DEVICES
F. SCHEDULES FOR MONITORING AND MAINTAINING EROSION CONTROL DEVICES
G. NAME AND PHONE NUMBERS OF PERSON RESPONSIBLE FOR MONITORING AND MAINTAINING EROSION CONTROL DEVICES
3. NO CONSTRUCTION ACTIVITIES SHALL BEGIN UNTIL THE SEDIMENT AND EROSION CONTROL PLAN HAS RECEIVED WRITTEN APPROVAL FROM
THE ENGINEER.
4. THE CONTRACTOR SHALL UPDATE THE SEDIMENT AND EROSION CONTROL PLAN WHENEVER THERE IS A CHANGE IN CONSTRUCTION SEQUENCE OR ACTIVITIES THAT HAS A SIGNIFICANT EFFECT ON THE POTENTIAL FOR THE DISCHARGE OF POLLUTANTS OFF SITE OR INTO ANY RECEIVING WATER AND SHALL SUBMIT THE UPDATED PLAN FOR REVIEW AND APPROVAL BY THE ENGINEER.
5. EROSION AND SEDIMENT CONTROLS SHALL BE PLACED PRIOR TO OR AS THE FIRST STEP IN CONSTRUCTION AND SHALL BE IN PLACE BEFORE
DISTURBING SOIL UPSTREAM OF THE CONTROL.
6. FIELD CONDITIONS MAY REQUIRE THE USE OF ADDITIONAL TYPES AND QUANTITIES OF SEDIMENT AND EROSION CONTROL DEVICES DURING CONSTRUCTION AS DETERMINED BY THE CONTRACTOR, THE ENVIRONMENTAL INSPECTOR, OR THE ENGINEER.
7. THE CONTRACTOR SHALL INSPECT ALL SEDIMENT AND EROSION CONTROL DEVICES PRIOR TO SUSPENSION OF WORK ACTIVITIES EACH DAY, IMMEDIATELY AFTER EACH RAINFALL, AND AT LEAST DAILY DURING PROLONGED RAINFALL TO ENSURE THAT THE DEVICES ARE PROPERLY LOCATED AND MAINTAINED FOR EFFECTIVENESS. ANY REQUIRED REMEDIAL ACTION SHALL BE PERFORMED IMMEDIATELY.
8. SEDIMENT TRAPPED BY THE EROSION CONTROL DEVICES IS TO BE REMOVED BY THE CONTRACTOR AFTER EACH RAINSTORM.
9. THE AMOUNT OF AREA DISTURBED AT ONE TIME SHALL BE LIMITED TO THE MINIMUM NECESSARY TO ADEQUATELY IMPLEMENT THE WORK.
CONSTRUCTION OPERATIONS SHALL BE CONTROLLED TO MINIMIZE UNPROTECTED AREAS EXPOSED TO WEATHER, AND AREAS OUTSIDE THE
LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED.
10. EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN LOCATIONS WHERE IT COULD BE WASHED AWAY BY HIGH WATER OR BY STORMWATER RUNOFF, AND STOCKPILES SHALL BE COVERED OR ENCIRCLED WITH SEDIMENT CONTAINMENT DEVICES.
11. DURING THE INSTALLATION OF STORM DRAIN OR UTILITY PIPING, SYNTHETIC BALE BARRIERS SHALL BE PLACED BELOW THE WORK ZONES TO
AID IN CONTROLLING THE TRANSFER OF ERODED MATERIAL OFF SITE.
12. NEW AND EXISTING DRAINAGE STRUCTURES SHALL BE PROTECTED FROM SILTATION DURING CONSTRUCTION. BARRIERS SHALL BE PLACED AROUND ALL INCOMPLETE STORMWATER INLETS AND MANHOLES DURING CONSTRUCTION. CURB INLET FILTERS SHALL BE PLACED ACROSS
THE THROATS OF ALL EXISTING AND COMPLETED CURB INLETS.
13. EXISTING FLOW CAPACITY SHALL BE MAINTAINED IN THE DRAINAGE SYSTEMS TO CONVEY RUNOFF FROM RAINSTORMS THAT OCCUR DURING CONSTRUCTION. EXISTING DRAINAGE PIPES THAT ARE NOTED TO BE PLUGGED OR REMOVED SHALL REMAIN IN SERVICE UNTIL FLOWS CAN BE DIVERTED TO THE NEW DRAINAGE SYSTEM. WHERE NEW PIPES ARE TO BE INSTALLED IN CLOSE PROXIMITY TO EXISTING PIPES THAT ARE TO BE REMOVED, PROVISIONS SHALL BE MADE TO DIVERT FLOWS FROM THE EXISTING PIPES TO THE NEW PIPES PRIOR TO RAINSTORMS. TEMPORARY PIPES SHALL BE PLACED FOR THIS PURPOSE PRIOR TO SUSPENSION OF WORK ACTIVITIES EACH DAY.
14. NO MORE THAN 500 FEET OF STORM DRAIN OR UTILITY PIPING SHALL BE INSTALLED WITHOUT BACKFILLING AND COMPACTING THE PIPE
TRENCH.
15. STABILIZATION MEASURES SHALL BE INITIATED FOR EROSION AND SEDIMENT CONTROL ON DISTURBED AREAS AS SOON AS PRACTICABLE, BUT IN NO CASE MORE THAN 14 DAYS AFTER CONSTRUCTION ACTIVITY IN THOSE PORTIONS OF THE SITE HAS TEMPORARILY OR
PERMANENTLY CEASED.
16. PERMANENT SOIL EROSION CONTROL MEASURES FOR ALL DISTURBED LAND AREAS SHALL BE COMPLETED IMMEDIATELY AFTER FINAL GRADING. WHEN IT IS NOT POSSIBLE TO PERMANENTLY PROTECT A DISTURBED AREA IMMEDIATELY AFTER GRADING OPERATIONS, TEMPORARY EROSION CONTROL MEASURES SHALL BE INSTALLED. ALL TEMPORARY EROSION CONTROL DEVICES SHALL BE MAINTAINED
UNTIL PERMANENT MEASURES ARE IN PLACE AND ESTABLISHED.
SUPPLEMENTAL GENERAL NOTES - TREE PROTECTION
1. BARRICADE FENCING SHALL BE INSTALLED AT OR NEAR THE CRITICAL PROTECTION ZONE OF EACH TREE TO BE PROTECTED PRIOR TO INITIATION OF ANY CONSTRUCTION ACTIVITY, AND THE FENCING SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION ACTIVITY HAS BEEN
COMPLETED.
2. ALL ROOTS 3/4" IN DIAMETER AND LARGER OF TREES TO BE PROTECTED OR PRESERVED THAT ARE EXPOSED DURING TRENCHING AND EXCAVATION SHALL BE CLEANLY CUT WITH A HANDSAW AND COVERED IMMEDIATELY WITH SOIL OR KEPT MOISTENED WITH WET BURLAP OR PEAT MOSS UNTIL THE TRENCH CAN BE FILLED. WHEN IT IS NOT POSSIBLE TO BACKFILL IN THE SAME DAY, THE ROOTS SHALL BE FRESHLY CUT WITH A HANDSAW A REASONABLE DISTANCE FROM THE ORIGINAL CUT AND BACKFILLED IMMEDIATELY TO AVOID SOIL OR ROOT
DEHYDRATION.
GENERAL PAY ITEM NOTES
1. NO SEPARATE PAYMENT WILL BE MADE FOR DEWATERING AND/OR BYPASS PUMPING. THE COSTS FOR DEWATERING AND BYPASS PUMPING
SHALL BE INCLUDED IN THE UNIT PRICE FOR PIPE CUJLVERT.
2. NO SEPARATE PAYMENT WILL BE MADE FOR GEOTEXTILE FABRIC OR FILTER FABRIC. THE COSTS FOR THESE ITEMS SHALL BE INCLUDED IN
THE UNIT PRICE FOR PIPE CULVERT.
3. NO SEPARATE PAYMENT WILL BE MADE FOR VIDEO TAPING PIPE CULVERTS. THE COSTS FOR VIDEO TAPING ARE INCLUDED IN THE UNIT
PRICES FOR PIPE CULVERT.
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
G E
N E
R A
L N
O T
E S
ORANGE COUNTY NOTES #2 (22" X 34")
WV
COM
WV
H
Y D
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
PRELIMINARYPRELIMINARY
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
T O
P O
G R
A P
H
IC
S U
R V
E Y
TOPO SURVEY (22" X 34")
THE ELECTRONIC SIGNATURE IS IN COMPLIANCE WITH F.A.C. 5J-17.602(3)
TV
H
Y D
EH
TS
THH
C O
ARV
RCW
RW
R
FO
G
COM
TRF
PX
te
FOH
CTV
E
T
0' 20'
BFA ENVIRONMENTAL CONSULTANTS
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST STREET
ORLANDO, FLORIDA 32803
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
PARCEL ID# 21-22-30-3932-05-270
AutoCAD SHX Text
PARCEL ID# 21-22-30-3932-05-010
AutoCAD SHX Text
FND 5/8" IR (NO ID)
AutoCAD SHX Text
FND 1/2" IR (NO ID)
AutoCAD SHX Text
APPARENT R/W
AutoCAD SHX Text
APPARENT R/W
AutoCAD SHX Text
APPARENT R/W
AutoCAD SHX Text
APPARENT R/W
AutoCAD SHX Text
APPARENT R/W
AutoCAD SHX Text
INV. 18" RCP MES EL. 96.30'
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
JAMAJO BLVD (60' R/W PER PLAT)
AutoCAD SHX Text
LOT 1, BLOCK D JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 2, BLOCK D JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 28, BLOCK E JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 27, BLOCK E JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 1, BLOCK E JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 2, BLOCK E JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 18, BLOCK B JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 17, BLOCK B JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 16, BLOCK B JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 15, BLOCK B JAMAJO (PB J, PG 88)
AutoCAD SHX Text
FND 1/2" IP (NO ID)
AutoCAD SHX Text
LOT 1, BLOCK C JAMAJO (PB J, PG 88)
AutoCAD SHX Text
LOT 2, BLOCK C JAMAJO (PB J, PG 88)
AutoCAD SHX Text
APPARENT R/W
AutoCAD SHX Text
PARCEL ID# 21-22-30-3932-04-010
AutoCAD SHX Text
PARCEL ID# 21-22-30-3932-03-010
AutoCAD SHX Text
PARCEL ID# 21-22-30-3932-02-150
AutoCAD SHX Text
PARCEL ID# 21-22-30-3932-02-170
AutoCAD SHX Text
BEACH BLVD (60' R/W PER PLAT)
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC DRIVE
AutoCAD SHX Text
GRAVEL DRIVE
AutoCAD SHX Text
CONC DRIVE
AutoCAD SHX Text
CONC DRIVE
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
ASPHALT DRIVE
AutoCAD SHX Text
CONC DRIVE
AutoCAD SHX Text
CONC DRIVE
AutoCAD SHX Text
CONC
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
SPEED BUMP
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
CHAIN LINK FENCE
AutoCAD SHX Text
FENCE GATE
AutoCAD SHX Text
EDGE OF WATER EL. 95.99' (8/18/2023)
AutoCAD SHX Text
POST & CHAIN FENCE
AutoCAD SHX Text
12" CMP E. INV. EL. 98.35' W. INV. EL. 98.60'
AutoCAD SHX Text
CONC HEADWALL
AutoCAD SHX Text
CONC HEADWALL
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
CONC HEADWALL
AutoCAD SHX Text
CONC HEADWALL
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
15" RCP INV. EL. 96.54'
AutoCAD SHX Text
DITCH
AutoCAD SHX Text
15" RCP INV. EL. 96.97'
AutoCAD SHX Text
15" RCP E. INV. EL. 98.13' W. INV. EL. 97.86'
AutoCAD SHX Text
15" CMP E. INV. EL. 98.56' W. INV. EL. 98.33'
AutoCAD SHX Text STORM INLET TOP EL. 98.84' W. WEIR EL. 98.44' N. INV. 18" RCP EL. 96.42' E. INV. 18" RCP EL. 96.49' S. INV. 15" RCP EL. 96.44'
AutoCAD SHX Text STORM MANHOLE TOP EL. 99.96' E. INV. 15" RCP EL. 96.93' S. INV. 15" RCP EL. 96.94' W. INV. 18" RCP EL. 96.99'
AutoCAD SHX Text
STORM INLET TOP EL. 98.90' E. INV. 12" CPP EL. 97.46' W. INV. 15" RCP EL. 96.00'
AutoCAD SHX Text STORM MANHOLE TOP EL. 100.14' E. INV. 12" CPP EL. 97.56' W. INV. 12" CPP EL. 97.53'
AutoCAD SHX Text
STORM INLET TOP EL. 99.50' E. WEIR EL. 99.04' W. INV. 12" CPP EL. 96.69'
AutoCAD SHX Text
12" CMP N. INV. EL. 98.33' S. INV. EL. 98.18'
AutoCAD SHX Text
15" RCP N. INV. EL. 98.28' S. INV. EL. 98.30'
AutoCAD SHX Text
CONC FLUME
AutoCAD SHX Text
CONC
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text TOPOGRAPHIC SURVEY SECTION 21, TOWNSHIP 22 SOUTH, RANGE 30 EAST CITY OF ORLANDO, ORANGE COUNTY, FLORIDA.ORANGE COUNTY, FLORIDA.
AutoCAD SHX Text Surveyor Certification This Topographic Survey was prepared under my direction and is true and correct to the best of my knowledge and belief. This Topographic Survey was performed in conformance with the “Standards of Practice” as contained in Chapter Standards of Practice” as contained in Chapter as contained in Chapter 5J-17, Florida Administrative Code, pursuant to Florida Statute 472. __________________________________________ Genel J. Sturgeon, PLS Date Date Florida Surveyor and Mapper PSM 5866 Barnes Ferland and Associates LB 7774 *Not valid without the signature and original raised seal of the Florida licensed surveyor and mapper
AutoCAD SHX Text
CONC
AutoCAD SHX Text
EL
AutoCAD SHX Text
INV
AutoCAD SHX Text
TYP
AutoCAD SHX Text
DE
AutoCAD SHX Text ABBREVIATION LEGEND ABBREVIATION LEGEND - ASBESTOS CONCRETE PIPE - CAMPHOR - CONCRETE - CORRUGATED METAL PIPE - CORRUGATED PLASTIC PIPE - DUCTILE IRON PIPE - DRAINAGE AND UTILITY EASEMENT - DRAINAGE EASEMENT - ELEVATION - FOUND - IDENTIFICATION - INVERT - IRON PIPE - IRON ROD AND CAP - IRON ROD - LICENSED BUSINESS - NAIL AND DISK - PAGE - PARKER KALON NAIL - PERMANENT CONTROL POINT - PLAT BOOK - POLYVINYL CHLORIDE - REINFORCED CONCRETE PIPE - RIGHT OF WAY - TYPICAL - UTILITY EASEMENT - VITRIFIED CLAY PIPE
AutoCAD SHX Text R/W
AutoCAD SHX Text
IRC
AutoCAD SHX Text
FND
AutoCAD SHX Text
ID
AutoCAD SHX Text
PG
AutoCAD SHX Text
PB
AutoCAD SHX Text
IP
AutoCAD SHX Text
PKN
AutoCAD SHX Text
DUE
AutoCAD SHX Text
PCP
AutoCAD SHX Text
CMP
AutoCAD SHX Text
RCP
AutoCAD SHX Text
IR
AutoCAD SHX Text
LB
AutoCAD SHX Text N&D
AutoCAD SHX Text
CAMPH
AutoCAD SHX Text
DIP
AutoCAD SHX Text
PVC
AutoCAD SHX Text
UE
AutoCAD SHX Text
6" OAK
AutoCAD SHX Text E
AutoCAD SHX Text
WV
AutoCAD SHX Text
IRR
AutoCAD SHX Text W/M
AutoCAD SHX Text C
AutoCAD SHX Text SYMBOL LEGEND SYMBOL LEGEND - AIR RELEASE VALVE - CABLE TV HAND HOLE - CABLE TV PEDESTAL - CONTROL PANEL - COMMUNICATIONS BOX - COMMUNICATIONS HAND HOLE - CLEANOUT - ELECTRIC BOX - ELECTRIC HAND HOLE - ELECTRIC MANHOLE - ELECTRIC METER - ELECTRIC TRANSFORMER - FIBER OPTIC HAND HOLE - FIBER OPTIC MARKER - FIRE HYDRANT - GAS MARKER - GAS VALVE - GUY WIRE - IRRIGATION VALVE - LIGHT POLE - MAST ARM - MAIL BOX - METAL SIGN - PEDESTRIAN CROSSING POLE - RECLAIM WATER MARKER - RECLAIM WATER METER - RECLAIM WATER VALVE - SANITARY MANHOLE - TELEPHONE HAND HOLE - TELEPHONE PEDESTAL - TRAFFIC HAND HOLE - TRAFFIC SIGNAL BOX - TREE (SIZE, TYPE) - UTILITY POLE - WATER METER - WATER VALVE - WELL
AutoCAD SHX Text S
AutoCAD SHX Text
GV
AutoCAD SHX Text
EM
AutoCAD SHX Text
VCP
AutoCAD SHX Text W
AutoCAD SHX Text
ACP
AutoCAD SHX Text
CPP
AutoCAD SHX Text (P)
AutoCAD SHX Text
OR
AutoCAD SHX Text
CH
AutoCAD SHX Text
- CALCULATED - PER DESCRIPTION - PER PLAT - CURVE DELTA ANGLE - CURVE RADIUS - CURVE LENGTH - CURVE CHORD BEARING - CURVE CHORD LENGTH - OFFICIAL RECORDS BOOK - POINT OF CURVATURE - POINT OF TANGENCY
AutoCAD SHX Text
PC
AutoCAD SHX Text
PT
AutoCAD SHX Text
CB
AutoCAD SHX Text Δ
AutoCAD SHX Text (D)
AutoCAD SHX Text C
AutoCAD SHX Text (C)
AutoCAD SHX Text R
AutoCAD SHX Text UNDERGROUND UTILITY LEGEND UNDERGROUND UTILITY LEGEND - BURIED ELECTRICAL LINE - BURIED TELEPHONE LINE - BURIED FIBER OPTIC LINE - BURIED FORCE MAIN - BURIED GAS LINE - OVERHEAD UTILITY LINE - BURIED RECLAIM WATER MAIN - BURIED TRAFFIC SIGNAL LINE - BURIED CABLE LINE - BURIED UNKNOWN UTILITY LINE - BURIED WATER MAIN - END OF INFORMATION
AutoCAD SHX Text
OHU
AutoCAD SHX Text
WM (B)
AutoCAD SHX Text
FM (B)
AutoCAD SHX Text
BT (B)
AutoCAD SHX Text
BE (B)
AutoCAD SHX Text
UNK (B)
AutoCAD SHX Text
RWM (B)
AutoCAD SHX Text
TV (B)
AutoCAD SHX Text
TRF (B)
AutoCAD SHX Text
FO (B)
AutoCAD SHX Text G (B)
AutoCAD SHX Text Surveyor's Notes 1. This Topographic Survey is not valid unless signed and embossed with the raised seal of a Florida licensed Surveyor and Mapper. 2. Lands were not researched by this firm for matters such as ownership, easements, right of way or other matters in the public records that may affect these lands. A title report was not provided to the Surveyor at the time of survey. 3. Coordinates are relative to the Florida State Plane Coordinate System, East Zone, North American Datum of 1983/1990 Adjustment. 4. Elevations shown hereon are relative to North American Vertical Datum of 1988 (NAVD 88) and based on the following Orange County benchmarks: 11-012 - Elevation 105.044' 11-011 - Elevation 108.078' 5. Last day in the field: 8/24/2023. 6. Graphic symbols shown hereon may not be to scale. 7. This Topographic Survey is certified true and correct to: Singhofen & Associates, Inc. 8. No underground structures or foundations were located by this survey. 9. This Topographic Survey is of the area as specified by the Client only. 10. This is not a Boundary Survey and does not purport to be one.
COM
WV
H
Y D
0+20 0+40 0+60 0+80 1+20 1+40 1+60 1+80 2+20 2+40 2+60 2+801+00 2+00 3+00 0+20 0+40 0+60 0+80 1+20 1+40 1+60 1+80 2+20 2+40 2+60 2+801+00 2+00 3+00
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
P L
A N
A N
D P
R O
F
IL
E
PLAN
SCALE AS NOTED
PROFILE
1" = 20' (HORIZONTAL), 1" = 2' (VERTICAL)
0+00 1+00 2+00 3+00 4+00
ALL ELEVATIONS IN FT, NAVD
B E
A C
H B
O U
L E
V A
R D
0' 20'
PD-01
BASELINE "A"
PD-01PD-02
PD-02
BASELINE COORDINATE GEOMETRY
B01 BEGIN BASELINE
B02 INFLECTION POINT ON BASELINE
1536135.5360
NUMBER EASTINGDESCRIPTION NORTHING
1536137.1060 551842.5000 551891.9090
B03 INFLECTION POINT ON BASELINE 1536140.6380 551941.6740
B04
INFLECTION POINT ON BASELINE 1536144.7800 551991.2970B05
INFLECTION POINT ON BASELINE 1536148.7850 552040.5630B06
INFLECTION POINT ON BASELINE 1536151.4560 552073.3920B07
INFLECTION POINT ON BASELINE 1536157.4250 552140.0340B08
END BASELINE 1536159.6187 552161.5272
STATION
0+00.00 0+49.43 0+99.32
1+49.12 1+98.55 2+31.49 2+98.40 3+20.00
OFFSET
0.00' 0.00' 0.00'
0.00' 0.00' 0.00' 0.00' 0.00'
SURVEY BENCHMARK 1536155.0030 551941.4810 1+00.33 100.76' L
B09
STATION 0+00
BEGIN BASELINE
WHERRELL
4395 BEACH BOULEVARD
PARCEL 21-22-30-3932-03-010
B01 B02
B03
B04
B05
BEACH BOULEVARD
PARCEL 21-22-30-3932-02-170
4401 BEACH BOULEVARD
NOEL-CORNELISON
B07
B06
PARCEL 21-22-30-3932-02-150
4445 BEACH BOULEVARD
STEFFENHAGEN
B08 B09
STATION 3+20
END BASELINE
PARCEL 21-22-30-3932-04-010
1224 JAMAJO BOULEVARD
LUGO
JA
M
A
JO
B O
U L
E V
A R
D
PARCEL 21-22-30-3932-05-270
1225 JAMAJO BOULEVARD
SMITH
COSTELLO
4444 BEACH BOULEVARD
PARCEL 21-22-30-3932-05-010
ALONG BASELINE
EXISTING GRADE
S. INV. 15" RCP EL. 96.44
E. INV. 18" RCP EL. 96.49
N. INV. 18" RCP EL. 96.42
W. SLOT EL. 98.44
TOP EL. 98.84
EXISTING 18" RCP
EXISTING 15" RCP
EXISTING 18" RCP
EXISTING 15" RCP
W. INV. 18" RCP EL. 96.99
S. INV. 15" RCP EL. 96.94
E. INV. 15" RCP EL. 96.93
TOP EL. 99.96
W. INV. 15" RCP EL. 96.00
E. INV. 12" CPP EL. 97.46
TOP EL. 98.90
EXISTING
12" CPP
12" CPP
EXISTING
W. INV. 12" CPP EL. 96.69
E. SLOT EL. 99.04
TOP EL. 99.50
W. INV. 12" CPP EL. 97.53
E. INV. 12" CPP EL. 97.56
TOP EL. 100.14
PD-03
PROPOSED 7 LF ~ 15" RCP @ 1.43%
PD-03
H.P.H.P.
EXISTING STORM INLET
EXISTING STORM MANHOLE
EXISTING STORM INLET
EXISTING STORM MANHOLE
EXISTING STORM INLET
L.P.
SEE THE GRADING AND DRAINAGE
PLAN FOR A DETAIL OF THIS AREA
PROPOSED 7 LF ~ 15" RCP @ 1.43%
EXISTING 15" RCP
PLAN FOR A DETAIL OF THIS AREA
SEE THE PAVEMENT RESTORATION
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text D
AutoCAD SHX Text
INV. 18" RCP MES EL. 96.30'
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
HEDGE
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
12" CMP E. INV. EL. 98.35' W. INV. EL. 98.60'
AutoCAD SHX Text
15" RCP INV. EL. 96.54'
AutoCAD SHX Text
15" RCP INV. EL. 96.97'
AutoCAD SHX Text
15" RCP E. INV. EL. 98.13' W. INV. EL. 97.86'
AutoCAD SHX Text
15" CMP E. INV. EL. 98.56' W. INV. EL. 98.33'
AutoCAD SHX Text STORM INLET TOP EL. 98.84' W. WEIR EL. 98.44' N. INV. 18" RCP EL. 96.42' E. INV. 18" RCP EL. 96.49' S. INV. 15" RCP EL. 96.44'
AutoCAD SHX Text STORM MANHOLE TOP EL. 99.96' E. INV. 15" RCP EL. 96.93' S. INV. 15" RCP EL. 96.94' W. INV. 18" RCP EL. 96.99'
AutoCAD SHX Text
STORM INLET TOP EL. 98.90' E. INV. 12" CPP EL. 97.46' W. INV. 15" RCP EL. 96.00'
AutoCAD SHX Text STORM MANHOLE TOP EL. 100.14' E. INV. 12" CPP EL. 97.56' W. INV. 12" CPP EL. 97.53'
AutoCAD SHX Text
STORM INLET TOP EL. 99.50' E. WEIR EL. 99.04' W. INV. 12" CPP EL. 96.69'
AutoCAD SHX Text
12" CMP N. INV. EL. 98.33' S. INV. EL. 98.18'
15" RCP N. INV. EL. 98.28' S. INV. EL. 98.30'
1+80 2+20 2+40 2+60 2+802+001+80 2+20 2+40 2+60 2+802+00
PROPOSED CONCRETE APRON
PD-02
FDOT INDEX NO. 425-001, 425-010, 425-025
CONSTRUCT DRAINAGE INLET (<10')
TYPE "P-10" CURB INLET
INV. EL. 96.60 (15" N)
EDGE OF PAVEMENT EL. 99.38
STATION 1+85.06, OFFSET 12.45' L
N 1536160.0986, E 552026.1092
PD-01
FDOT INDEX NO. 425-001, 425-010, 425-025
TYPE "P-10" CURB INLET
CONSTRUCT DRAINAGE INLET (<10')
INV. EL. 96.10 (15" N)
EDGE OF PAVEMENT EL. 99.45
STATION 2+14.90, OFFSET 12.66' L
N 1536162.7387, E 552055.9227
SEE THE DRAINAGE STRUCTURE DETAILS
PROPOSED DRAINAGE STRUCTURES
PD-03
FDOT INDEX NOS. 425-001, 425-010
TYPE "P-7" WITH RING AND SOLID COVER
CONSTRUCT DRAINAGE MANHOLE (<10')
INV. EL. ±96.50 (15" E, W)
TOP EL. ±99.50 (FIELD ADJUST)
STATION 1+85.06, OFFSET 19.43' L
N 1536167.0723, E 552025.6764
SEE THE DRAINAGE STRUCTURE DETAILS
PROPOSED SWALE GRADING
BEACH BOULEVARDBASELINE "A"
PARCEL 21-22-30-3932-02-170
4401 BEACH BOULEVARD
NOEL-CORNELISON
ESTIMATED QUANTITIES
1 ROADWAY OPEN CUT
3 ASPHALT MILLING
6 TYPE "F" CURB AND GUTTER => 12 LF
7 DROP CURB => 21 LF
10 CONCRETE SIDEWALK (4" THICK) => 80 SF
11 CONCRETE DRIVEWAY (6" THICK) => 165 SF
FDOT INDEX 520-001
FDOT INDEX 520-001
FDOT INDEX 522-001
SEE THE DRAINAGE STRUCTURE DETAILS
M.E.
99.35
99.28 M.E.
M.E.
99.20
EXISTING HEDGE
EXISTING HEDGE
13 LANDSCAPE PLANTINGS
SEE THE NOTES ON THIS SHEET
PD-02
PD-03
INSET DETAIL NOTES - GENERAL
1. THE COSTS FOR EXCAVATION AND GRADING ARE INCIDENTAL TO THE
BID PRICE FOR CONCRETE DRIVEWAY AND SIDEWALKS.
2. THE COST FOR MODIFYING THE EXISTING DITCH BOTTOM INLET IS
INCIDENTAL TO THE BID PRICE FOR STORM PIPE.
3. THE EXISTING HEDGES AT 4401 BEACH BOULEVARD ARE TO BE
PROTECTED AND SHOULD REMAIN TO THE GREATEST EXTENT
PRACTICABLE. ANY HEDGES THAT HAVE TO BE REMOVED WILL BE
REPLACED IN ACCORDANCE WITH THE LANDSCAPE PLANTING LIST
PROVIDED WITHIN THE CONSTRUCTION PLANS.
SUBSTITUTION FOR INCREASING VERTICAL
TYPE "P-8" MANHOLE IS AN ACCEPTABLE
SEPARATION IF THE CONE RISER CAN BE
ACCOMMODATED BY THE PRECAST DESIGN
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
0' 5'
G R
A D
IN
G
A N
D D
R A
IN
A
G E
P L
A N
B
E A
C H
B O
U L
E V
A R
D
PARCEL 21-22-30-3932-02-150
4445 BEACH BOULEVARD
STEFFENHAGEN
PD-01
2 ROADWAY OPEN CUT
8 TYPE "F" CURB AND GUTTER => 35 LF
FDOT INDEX 520-001
9 FLARED END
FDOT INDEX 520-001
12 CONCRETE SIDEWALK (4" THICK) => 395 SF
FDOT INDEX 522-001
M.E.M.E.
98.9- -
4.7%±6%
2.8% 0.6%
2.0%
2.0%
PLAN
SCALE AS NOTED
xx.xxxx.xx
GRADING LEGEND
PROPOSED SPOT GRADE
PROPOSED SLOPEx.x%
EXISTING SPOT GRADE
INSET DETAIL
NOT TO SCALE
SEE THE INSET DETAIL
ON THIS SHEET
BEACH BOULEVARD
PARCEL 21-22-30-3932-02-170
4401 BEACH BOULEVARD
NOEL-CORNELISON
SEE THE NOTES ON THIS SHEET
SEE THE NOTES ON THIS SHEET
M.E.
.38
M.E.99.80
.32M.
E.
M.E.
99.
99.75 99.60
99.37 99.45
99.32 99.42
99.40 99.35
M.E.
99.38
99.51
M.E.
99.18 99.50
.1899 .50
99.1199.50
99.47 99.15
99.40 99.45
99.
3999.
.2999 .69
.75
.38
.43M.
E.
.44M.
E.
M.
E.
.45
99.82 99.38
99.26
99.72
99.59 99.90
.63
0.0
M.E.
99.52
0.0
0.1
±100 99.98
±99.6 M.E.
±99.6 M.E.
±100±100
100.01
100.10
99.85 100.20
99.90
100.30
99.62 100.00
99.70 100.10
99.78 99.90
99.59
99.80 99.43
M.E.
99.64 M.E.
.5- -
BEGIN TYPE "F" CURB
AND GUTTER TRANSITION
WITH NON-SHRINK GROUT
SEAL THE NEW PIPE CONNECTION
DITCH BOTTOM INLET AND
CORE BORE THE EXISTING
SPEED BUMP
ASPHALT
DRIVEWAY
CONCRETE
DRIVEWAY
CONCRETE
DRIVEWAY
ASPHALT
CONCRETE
HEDGE
DRIVEWAY
CONCRETE
5 ALUMINUM PIPE GUIDERAIL => 15 LF
FDOT INDEX 515-070
ALUMINUM PIPE GUIDERAIL
SEE THE MISCELLANEOUS DETAILS
BEYOND THE RING AND COVER
4 ASPHALT PAVEMENT
SEE THE PAVEMENT RESTORATION PLAN
SEE THE PAVEMENT RESTORATION PLAN
SEE THE PAVEMENT RESTORATION PLAN
SEE THE PAVEMENT RESTORATION PLAN
PD-01
EXTEND CONCRETE SIDEWALK 12"
INSET DETAIL NOTES - SIDEWALK
1. ALL SIDEWALKS SHALL CONFORM TO ADA REQUIREMENTS PER FDOT
INDEX 522-002.
2. CROSS SLOPE FOR ALL PEDESTRIAN ACCESSIBLE ROUTES SHALL BE
1.0% MINIMUM AND 2.0% MAXIMUM.
3. RUNNING SLOPE FOR PEDESTRIAN ACCESSIBLE ROUTES WITHOUT
HANDICAP RAMPS AND HANDRAILS SHOWN NOT EXCEED 5.0%.
WV
H
Y D
0+80 1+20 1+40 1+60 1+80 2+20 2+40 2+60 2+801+00 2+00 3+000+80 1+20 1+40 1+60 1+80 2+20 2+40 2+60 2+801+00 2+00 3+00
ESTIMATED QUANTITIES
1 ROADWAY OPEN CUT => 180 SF
3 ASPHALT MILLING (1" AVG. DEPTH) => 4,450 SF
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
0' 10'
P A
V E
M E
N T
R E
S T
O R
A T
IO
N
P L
A N
B
E A
C H
B O
U L
E V
A R
D
2 ASPHALT PAVEMENT (2" THICK) => 180 SF
PLAN
SCALE AS NOTED
DRIVEWAY
CONCRETE
4 ASPHALT PAVEMENT (1" THICK) => 4,450 SF
STANDARD ROADWAY OPEN CUT AND PAVEMENT RESTORATION DETAIL
NOT TO SCALE
SURFACE REPLACEMENT TO BE
SUPERPAVE ASPHALTIC CONCRETE
SP-9.5, FINE GRADED TRAFFIC C MIX
VARIES
PIPE DIAM.
MECHANICALLY SAW-CUT
SURFACE JOINT SHALL BE
50' (TYP.)
EXISTING ASPHALT
EXISTING BASE
EXISTING SUB-GRADE
FDOT CLASS NS CONCRETE
FDOT EXCAVATABLE
FLOWABLE FILL
1' MIN.
2' MIN.
1' MIN.
EXISTING SUB-GRADE
8"
3' (T
YP
EXISTING ASPHALT
EXISTING BASE
MECHANICALLY SAW-CUT
SURFACE JOINT SHALL BE
50' (TYP.)
PARCEL 21-22-30-3932-02-170
4401 BEACH BOULEVARD
NOEL-CORNELISON
PARCEL 21-22-30-3932-02-150
4445 BEACH BOULEVARD
STEFFENHAGEN
BASELINE "A"
JA
M
A
JO
B O
U L
E V
A R
D
BEACH BOULEVARD
PARCEL 21-22-30-3932-05-270
1225 JAMAJO BOULEVARD
SMITH
STATION 1+24.77, 11.39' L
STATION 1+24.77, 15.20' R
STATION 3+15.16, 11.75' L
3 4
MECHANICALLY SAW-CUT
SURFACE JOINT SHALL BE
NOTES:
1. COST OF FDOT CLASS NS CONCRETE AND
FDOT EXCAVATABLE FLOWABLE FILL SHALL
BE INCLUDED IN THE PRICE OF PIPE.
ROAD OPEN CUT
2" MINIMUM THICKNESS
1 2 1 2
SEE THE NOTES ON THIS SHEET
EXISTING SPEED BUMP
NOTES:
1. COST OF REPLACING THE EXISTING SPEED
BUMP SHALL BE INCLUDED IN THE PRICE OF
ASPHALT MILLING AND ASPHALT PAVEMENT.DRIVEWAY
CONCRETE
DRIVEWAY
CONCRETE
DRIVEWAY
ASPHALT
WHERRELL
4395 BEACH BOULEVARD
PARCEL 21-22-30-3932-03-010
STATION 3+15.16, 11.67' R
RESTORATION
BEGIN PAVEMENT
RESTORATION
END PAVEMENT
MECHANICALLY SAW-CUT
SURFACE JOINT SHALL BE
D
COM
WV
H
Y D
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
P O
L L
U T
IO
N
C O
N T
R O
L S
0' 15'
POLLUTION CONTROLS
INLET PROTECTION
STAKED SILT FENCE (TYPE III)
TURBIDITY BARRIER
1. EROSION, SEDIMENT AND TURBIDITY
CONTROL SHALL BE MAINTAINED AT
ALL TIMES DURING CONSTRUCTION OF
THE PROJECT AND SHALL BE REMOVED
BY THE CONTRACTOR AFTER FINAL
ACCEPTANCE OF THE PROJECT BY THE
OWNER. THESE CONTROL MEASURES
ARE ONLY THE MINIMUM REQUIRED
AND ADDITIONAL CONTROLS SHALL BE
UTILIZED AS NEEDED, DEPENDENT
UPON ACTUAL SITE CONDITIONS AND
CONSTRUCTION OPERATIONS.
2. ALL DISTURBED AREAS WILL BE
BROUGHT TO FINAL GRADE, SEEDED
AND MULCHED OR SODDED AS SOON
AS POSSIBLE.
3. AREAS WHICH MAY ERODE DUE TO
SLOPES OR CONCENTRATED RUNOFF
DURING CONSTRUCTION WILL BE
PROTECTED WITH SILT FENCE OR
OTHER ALTERNATIVE METHODS.
PROJECT AREA
APPROXIMATE LIMITS OF LAND
DISTURBING ACTIVITIES
ROUTINE MAINTENANCE
DURING CONSTRUCTION
0.14 AC
1. NPDES PERMIT IS NOT REQUIRED.
SUSANNAH
LAKE
WHERRELL
4395 BEACH BOULEVARD
PARCEL 21-22-30-3932-03-010 PARCEL 21-22-30-3932-02-170
4401 BEACH BOULEVARD
NOEL-CORNELISON
PARCEL 21-22-30-3932-02-150
4445 BEACH BOULEVARD
STEFFENHAGEN
LUGO
1224 JAMAJO BOULEVARD
PARCEL 21-22-30-3932-04-010
JA
M
A
JO
B O
U L
E V
A R
D
PARCEL 21-22-30-3932-05-270
1225 JAMAJO BOULEVARD
SMITH
COSTELLO
4444 BEACH BOULEVARD
PARCEL 21-22-30-3932-05-010
BEACH BOULEVARD
AERIAL IMAGE DATED 2021
FDOT OFFICE OF SURVEYING & MAPPING
BEACH BOULEVARD
EXISTING OUTFALL DITCH
EXISTING OUTFALL PIPE
EDGE OF WATER
D
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
GREGORY A. TEAGUE, P.E.
REGISTRATION No. 47663
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.:
Fax: 407-358-5155
Certificate of Authorization No. 27770
Office: 407-992-9160
SAI-22004
GAT
CAD
DWH
JULY 2024
Pegasus Engineering, LLC
SHEET OF
July 29, 2024
B E
A C
H B
O U
L E
V A
R D
D R
A
IN
A G
E
IM
P R
O V
E M
E N
T S
T E
M P
O R
A R
Y E
R O
S
IO
N C
O N
T R
O L
D E
T
IA
L S
SILT FENCE
GRAVEL CONSTRUCTION ENTRANCE
TOTAL DEPTH
HEIGHT ABOVE WATER (24" MAX.)
TOP EL.
BOTTOM EL.
TOP EL.
BOTTOM EL.
FRONT VIEW
PROFILE VIEW
PROTECTED AREACONSTRUCTION AREA
EXISTING GROUND
EROSION / SILT
FLOW
6"
4" MIN. EMBEDMENT DEPTH
FILTER FABRIC
FILTER FABRIC (FDOT INDEX NO. 199)
FLOC LOGS
FLOATING TURBIDITY BARRIER
ROCK CHECK DAM
POLLUTION CONTROLS
6" MINIMUM
SEE PLAN
SEE
PLAN
FDOT #1 COARSE AGGREGATE
(2- TO 3-INCH DIAMETER STONE)
HARD SURFACE
PUBLIC ROAD
SOIL TRACKING PREVENTION DEVICE
SIDEWALK
SOCK COVERED
PERFORATED PIPE CONC. CURB
AND GUTTER
SANDBAGS
SIDEWALK
SANDBAGS
NOTES:
1. PLACE CURB TYPE SEDIMENT BARRIERS ON GENTLY SLOPING STREET SEGMENT, WHERE WATER CAN POND AND ALLOW
SEDIMENT TO SEPARATE FROM RUNOFF.
2. SANDBAGS OF EITHER BURLAP OR WOVEN GEOTEXTILE FABRIC ARE FILLED WITH GRAVEL LAYERED AND PACKED TIGHTLY.
3. LEAVE A ONE SANDBAG GAP IN THE TOP ROW TO PROVIDE A SPILLWAY FOR OVERFLOW.
4. INSPECT BARRIERS AND REMOVED SEDIMENT AFTER EACH STORM EVENT SEDIMENT AND GRAVEL MUST BE REMOVED
FROM THE TRAVELED WAY IMMEDIATELY.
5. AT THE END OF EACH WORKDAY, SWEEP OR SCRAPE UP SOIL TRACKED ONTO THE STREET.
CURB INLET OR DITCH BOTTOM INLET
(CURB INLET SHOWN FOR GRAPHICAL PURPOSES ONLY)
WRAP AND ENCAPSULATE INLET
GRATE WITH FILTER FABRIC
SYNTHETIC HAY BALES
OR SILT FENCE
INLET PROTECTION
NOTES:
1. ROCK MATERIAL SHALL BE FDOT AGGREGATE #1 (2- TO 3-INCH DIAMETER) STONE.
2. FILTER FABRIC SHALL BE INSTALLED PRIOR TO PLACEMENT OF ROCK TO PREVENT OVER-EXCAVATION DURING
ROCK REMOVAL.
3. FLOC LOGS WILL BE USED IN THE EVENT THAT BYPASS PUMPING IS REQUIRED DURING CONSTRUCTION, OR AS DIRECTED BY THE OWNER OR ENGINEER, TO MINIMIZE TURBIDITY DISCHARGED DOWNSTREAM (PROTECTED AREAS). FLOC LOGS TO BE SUPPLIED BY APPLIED POLYMER SYSTEMS, INC. OR APPROVED EQUIVALENT.
4. EROSION CAUSED BY FLOWS AROUND THE EDGES OF THE DAM SHALL BE CORRECTED IMMEDIATELY.
5. THE CONTRACTOR WILL BE REQUIRED TO REMOVE SEDIMENTS UPSTREAM OF THE DAM WHEN:
- THE ACCUMULATED SEDIMENT HAS REACHED ONE-HALF THE ORIGINAL HEIGHT OF THE DAM; OR
- AT THE DIRECTION OF THE OWNER OR ENGINEER.
6. AT THE END OF CONSTRUCTION, THE CONTRACTOR WILL BE REQUIRED TO REMOVE THE ROCK CHECK DAM, ANY
ACCUMULATED SEDIMENTS AND ROCK MATERIAL BOTH UPSTREAM AND DOWNSTREAM OF THE DAM.
NOT IN CONTRACT
NOT IN CONTRACT
AutoCAD SHX Text INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT WHEN NECESSARY.
AutoCAD SHX Text
REMOVED SEDIMENT SHALL BE DEPOSITED TO AN AREA THAT WILL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .