0011162841-0001 a.T his is a Non-Work Plan Task Order for the follow ing Area I & II, MA IDIQ Contractors only.

Contract Number: W91QVN-18-D-0021, 0022, 0023, 0024, 0025, 0026, 0027, 0028, 0029, 0030, 0031, 0032, 0033, 0034, 0035, 0040, 0041,0042, 0043, 0044, 0045, 0046, 0047, 0048, 0049, 0050, 0051.0162 b.I f the contractor is unable to submit the proposal in response to this RFP, the contractor shall submit the “No-offer letter” by closing date and time specified in the solicitation.

MR. SON, U KAP 02-7914-3354

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

24-May-2018

(RFP)

(IFB)

X

CALL:

Repair Bldg# 473

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________210 calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________Section F

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES X NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________ copies to perform the w ork required are due at the place specif ied in Item 8 by ___________ local time ______________07 Jun 2018 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, X is not required.

C. All of fers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______240 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

411TH CONTRACTING SUPPORT BRIGADE, KOREA

RCC YONGSAN, UNIT #15289

APO AP 96205-5289

UNITED STATES

W91QVN

PAGE OF PAGES

1 OF

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

03:00 PM (hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

130946

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: 755-0638 TEL: FAX:

W91QVN18R0129 24

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specified below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

W91QVN18R0129

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Job Repair Bldg #473

FFP

WORK CLASS: K

FOB: Destination

PURCHASE REQUEST NUMBER: 0011162841-0001

PSC CD: Z2FC

NET AMT

0002 1 Job Repair Bldg #473

FFP

WORK CLASS: L

FOB: Destination

PURCHASE REQUEST NUMBER: 0011162841-0001

PSC CD: Z2FC

0003 1 Lot Estimated Cost for War Hazzard

FFP

is zero (0).

FOB: Destination

Section C - Descriptions and Specifications

TECHNICAL PROVISIONS - I

STATEMENT OF WORK

PROJECT NO TITLE LOCATION

130946 Repair building No. 473 Camp Casey

1. DESCRIPTION: The work to be performed to repair building No. 473 is described below and executed by one or more of the groups.

1.1. Work by Contractor: The contractor shall provide all labor, tools, equipment, supplies and any other resources necessary to accomplish the scope of work contained herein as indicated in the drawings and in accordance with the specifications.

1.2. Work by In-House Labor: Not applicable to this project..

1.3. Work by Troop Labor: Not applicable to this project.

2. PRINCIPAL FEATURES: This project includes the following principal features:

2.1. Schedule #I, Repair (K): All work shall be in accordance with the attached drawings and specifications.

2.1.1. Civil Work

2.1.1.1. Replace 1.8m width sidewalk. (Drawing No. C-2, C-3)

2.1.1.2. Replace concrete step including handrail. (Drawing No. C-2, C-4)

2.1.1.3. Replace concrete curb. (Drawing No. C-2, C-3)

2.1.1.4. Restore Asphalt Concrete (AC) pavement.

2.1.1.5. Repair existing concrete open ditch including concrete support beam (100x100mm) on top of ditch on every 2.0m.

2.1.1.6. Restore solid sodding including top soil.

2.1.2. Architectural Work

2.1.2.1. Replace existing floor tile with new Polyvinyl Chloride Tile (PVCT) including Vinyl Cove Base (VCB) as shown on new floor plan and interior finish schedule. The existing concrete flooring shall be smooth, true, level plane with all defects such as rough or scaling concrete, low spots, high spots, painting, and uneven surface shall have been corrected for new flooring. Provide leveling concrete for existing concrete slab with government approval. (Drawing No. A-1, A-2, A-3, A-8)

2.1.2.2. Replace existing ceiling with new acoustical ceiling tile and metal suspension systems as shown on interior finish schedule. Replace existing aluminum louvers with new as shown on floor plans and detail drawings. (Drawing No. A-1, A-2, A-3, A-7, A-8)

2.1.2.3. Replace existing ceiling with new Gypsum Wall Board (GWB, normal, water resistant or 'X' type) ceiling including ceiling suspension system as shown on floor plans and finish schedule.

(Drawing No. A-1, A-2, A-3, A-7, A-8)

2.1.2.4. Replace existing gravel bed and concrete curb with new 100mm deep gravel bed and granite curb (minimum 300mm height) around building as shown on floor plans and detail drawing.

(Drawing No. A-1, A-2, A-4)

2.1.2.5. Replace existing Floor Tile (FT) and Glazed Ceramic Wall Tile (GCWT) with new including accessories, metal lath, mortar bed, and waterproofing in bathroom and shower room as shown on floor plans and detail drawings. (Drawing No. A-1, A-2, A-3, A-5, A-6, A-8)

2.1.2.6. Replace existing concrete slab as need to replace mechanical piping works. (Drawing No. A- 1, A-2)

2.1.2.7. Replace interior and exterior signages with new for all rooms as shown on elevations and signage schedule. (Drawing No. A-1, A-2, A-11)

2.1.2.8. Paint all existing exterior exposed Exterior Insulation and Finish System (EIFS), Concrete Masonry Unit (CMU), metal, woods, concrete surfaces, fascia, soffit and other components of exterior surface of the building as shown on floor plan and detail drawings.

2.1.2.9. Replace existing vanity cabinets including wall hung cabinet with new in all toilet as shown on new floor plans and detail drawing. (Drawing No. A-1, A-2, A-5, A-7)

2.1.2.10. Paint existing steel handrails and guardrails including sanding and primer in all stairs.

2.1.2.11. Replace existing pipe chases and pipe cover with new CMU, waterproof or x type of GWB including access door in each rooms for new mechanical piping system and duct as per floor plans, sections and detail drawings. (Drawing No. A-1, A-2, A-3, A-5, A-6, A-8)

2.1.2.12. Replace existing Fire Extinguisher Cabinets (FEC) with new as shown on new floor plans and detail drawing. (Drawing No. A-1, A-2)

2.1.2.13. Replace existing all doors and door frames with new including new hardware sets as shown on new floor plans and door schedule. (Drawing No. A-1, A-2, A-5, A-9, A-10)

2.1.2.14. Replace existing wooden sill for all windows with new as shown on door and window schedule. (Natural color, oak). (Drawing No. A-1, A-2, A-3, A-9)

2.1.2.15. Replace existing window horizontal mini blinds with news, fireproof type. (Drawing No. A-1, A-2, A-3, A-9)

2.1.2.16. Replace existing windows including insect screen with new aluminum thermal breaker type blast windows including insulating glass with 8.75mm thickness clear laminated glass + 12mm thickness air space + 6mm thickness tinted low-e tempered glass as shown on floor plans and window schedule. (Drawing No. A-1, A-2, A-3, A-9)

2.1.2.17. Replace existing metal shelf with mop rack with new in janitor rooms. (Drawing No. A-1, A- 2, A-5)

2.1.2.18. Replace existing wooden hanging rails and chair rails with new in each bed room and day rooms as shown on floor plans and sections. (Drawing No. A-1, A-2, A-3, A-5)

2.1.2.19. Replace rubber tiles with new including tread, riser and stair base in stair-1 and 2 as shown on floor plans and interior finish schedule. (Drawing No. A-1, A-2, A-3, A-8)

2.1.2.20. Replace existing aluminum louvers with new as shown on floor plans and detail drawings.

(Drawing No. A-1, A-2, A-4, A-9)

2.1.2.21. Replace existing all access doors on wall and ceiling with new. (Drawing No. A-1, A-2, A-3, A-5)

2.1.2.22. Apply epoxy coating with non-slip grits on existing floors as shown on interior finish schedule.

2.1.2.23. Replace wooden shelf, Stainless Steel (SST) rod with new in each closet as shown on floor plan and details. (Drawing No. A-1, A-2, A-4)

2.1.2.24. Paint on all interior surfaces including ceiling and wall as shown on interior finish schedule and elevations.

2.1.2.25. Replace plexi-info holder and card holder with new as shown on detail drawings. (Drawing No. A-1, A-2, A-11)

2.1.2.26. Replace existing quarry tile including quarry tile base with new as shown on floor plans and interior finish schedule. (Drawing No. A-1, A-2, A-8)

2.1.2.27. Replace existing concrete stoops with new as shown on floor plans. (Drawing No. A-1, A-2, A-4)

2.1.2.28. Replace counter table with new including shelves in admin office as shown on floor plans.

(Drawing No. A-1, A-2)

2.1.2.29. Replace existing metal door frame with new wooden molding in corridors as shown on floor plan. (Drawing No. A-1, A-2, A-5, A-8, A-9)

2.1.2.30. Block up door, window and louver openings with CMU, re-bar, and EIFS as shown on Mechanical drawings and floor plans.

2.1.2.31. Replace existing metal canopies with new as shown on floor plan and picture. (Drawing No.

A-1, A-2, A-4)

2.1.2.32. Apply acrylic fluid-applied waterproofing coating on existing roof as shown on floor plan and sections.

2.1.2.33. Replace GWB including metal studs in office area and day rooms as shown on floor plans and finish schedule. (Drawing No. A-1, A-2, A-3, A-7, A-8)

2.1.2.34. Replace existing bulletin board with new as shown on floor plans and picture. (Drawing No.

A-1, A-2, A-5, A-11)

2.1.3. Mechanical Work

2.1.3.1. Heating, Ventilating, and Air Conditioning (HVAC) system

2.1.3.1.1. Replace existing hot and chilled water circulation pumps, expansion tanks, air separators, 3-way mixing valve, carbon monoxide detector, detection controller, alarm gong, chemical feeders, and associated piping with new. (Drawing No. M-2,M-3,M-9,M-11,M-12)

2.1.3.1.2. Replace existing all drain and hot and chilled water piping throughout the building with new. (Drawing No. M-2,M-5,M-6,M-7,M-8,M-9,M-10,M-11)

2.1.3.1.3. Replace existing air handling units and associated ductwork in laundry room with new.

(Drawing No. M-2,M-3,M-10)

2.1.3.1.4. Replace existing fan coil units, outside air intake boxes, controls, and associated piping with new. (Drawing No. M-2,M-3,M-5,M-6,M-7,M-8,M-10,M-12)

2.1.3.1.5. Replace existing exhaust fans within the mechanical room, laundry room, toilet janitor room, and associated duct with new. (Drawing No. M-2,M-3,M-5,M-6,M-7,M-8,M-9,M-13)

2.1.3.1.6. Replace existing bathroom exhaust fans and ducts with new. (Drawing No. M-2,M-3,M- 10,M-13)

2.1.3.1.7. Replace existing electric cabinet unit heaters, thermostats, and unit heater with new.

(Drawing No. M-2,M-3,M-4,M-5,M-7,M-9)

2.1.3.1.8. Replace existing fin-tube radiators, split air conditioning unit, and associated piping with new. (Drawing No. M-2,M-4,M-5,M-6,M-7,M-8,M-10)

2.1.3.1.9. Replace existing unit heater, range hood and 100mm dryer vent connect to dryer, motorized Outside Air (O.A.) damper and intake louvers with new. (Drawing No. M-2,M-4,M-5,M-6,M- 7,M-8,M-10)

2.1.3.1.10. All mechanical systems shall be tested, adjusted, and balanced by the contractor in strict accordance with applicable sections of division 15 - mechanical O&MA standard technical specifications for miscellaneous projects, Korea. The HVAC Testing, Adjusting, and Balancing (TAB) report shall be submitted to the COR for government review and approval.

2.1.3.2. Plumbing system

2.1.3.2.1. Replace existing domestic hot water storage tank, domestic hot water circulation pump, domestic hot water re-circulation pump, expansion tank, thermostatic mixing valve and associated accessories with new. (Drawing No. M-2,M-3,M-13,M-16)

2.1.3.2.2. Replace existing all domestic hot and cold water piping and water hammer arresters with new. (Drawing No. M-2,M-14,M-15,M-16,M-17,M-18,M-19)

2.1.3.2.3. Replace existing all sewer, vent piping, floor drain, and cleanout with new. (Drawing No.

M-2,M-14,M-15,M-16,M-17,M-18,M-19)

2.1.3.2.4. Replace existing bathroom plumbing fixtures and associated piping with new. (Drawing No.

M-2,M-14,M-15,M-17,M-18,M-19)

2.1.3.2.5. Replace existing electric water coolers, sinks and valve boxes within the laundry room with new. (Drawing No. M-2,M-14,M-15,M-18,M-19)

2.1.3.2.6. Replace existing Back Flow Preventer (BFP) and Pressure Reducing Valve (PRV) assembly including pipe supports and hose bibb with new. (Drawing No. M-2,M-16)

2.1.3.3. Sprinkler work

2.1.3.3.1. Replace existing fire protection system with wet type sprinkler system and associated piping. (Drawing No. M-2,M-20,M-21,M-22,M-23,M-24,M-25)

2.1.4. Electrical Work

2.1.4.1. Replace existing lighting fixtures, exit lights, exterior lights, toggle switches, 3-way switches, photocell, lighting contactor, wires and conduits with new. (Drawing No. E-1, E-3, E-4, E-5, E-8)

2.1.4.2. Replace existing panelboards, watt hour meter, panelboard front covers, receptacles and cover plates, circuit breaker, and associated wiring and conduit with new. (Drawing No. E-1, E-6, E- 7, E-8)

2.1.4.3. Replace existing safety switches, combination motor starters, magnetic motor starters, manual motor starters, junction boxes, control system, wires and conduits for HVAC system with new. (Drawing No. E-1, E-7, E-8)

2.1.4.4. Replace fire alarm control system with new addressable fire alarm control and mass notification system panel, manual pull station, smoke detector and relay module, building transmitter, antenna, visual signal strobes, microphone, speaker device, local operating console, and associated wiring and conduit. (Drawing No. E-1, E-13, E-14)

2.1.4.5. Replace existing telephone terminal board, equipment rack and accessories, outlets including cover plates, and associated wiring and conduit with new. (Drawing No. E-1, E-9, E-10)

2.1.4.6. Replace existing CATV cabinets and pull boxes, outlets including cover plates, and associated wiring and conduit with new. (Drawing No. E-1, E-11, E-12)

2.1.4.7. Replace existing exterior underground telecommunication line, hand hole and accessories with new. (Drawing No. E-1, E-2)

2.1.4.8. Remove and reinstall existing CCTV cameras and monitoring system including associated accessories.

2.1.4.9. Remove existing public address system including speakers.

2.2. Schedule #II, New Construction (L): All work shall be in accordance with the attached drawings and specifications.

2.2.1. Civil Work

2.2.1.1. Install 150mm diameter Polyvinyl Chloride (PVC) water line including Post Indicator Valve

(PIV).

2.2.2. Architectural Work

2.2.2.1. Install kitchenette and counter top in each day room as shown on floor plans and details drawings.

2.2.2.2. Install new GWB ceiling including ceiling suspension system in each bed room as shown on floor plans, sections and finish schedule.

2.2.2.3. Construct new CMU walls including re-bars (hd13 @400 OC) in room No. 115 as shown on floor plans, sections, and finish schedule.

TECHNICAL PROVISIONS - II

TECHNICAL DETAIL SPECIFICATIONS

GENERAL: The specification sections listed below are applicable to this project. The specifications are from the “Standard Technical Specifications for O&MA Projects, Korea, Revision 1” (2014 OMA SPECS, REVISION 1), dated 20151030, located on the http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/2014-OMA-SPECS_REVISION- 1.pdf. The electronic version of the specifications is Acrobat® PDF format and can be read with the Acrobat Reader® software.

Changes to the Standard Technical Detail Specifications: None

TECHNICAL PROVISIONS - III

SPECIAL CONDITIONS

1. The contractor shall have personnel on site for the sprinkler work and the fire alarm work upon Government's direction, who are certified by the National Institute for Certification in Engineering Technologies (NICET) Level III or equivalent. Equivalent Certificates in Korea are the followings which are issued by the Human Resource Development Service of Korea. If the contractor doesn’t have personnel who are certified by NICET, the contractor shall have two personnel that one is certified for (1) and the other for (2) below.

(1) Engineer Fire Fighting Facilities - Electrical (소방설비기사 -전기)

(2) Engineer Fire Fighting Facilities - Mechanical (소방설비기사 -기계)

2. Environmental Requirements in Contract

The Contractor shall perform work consistent with the relevant policy and objectives identified in Installation’s Environmental Management System (EMS). The Contractor shall perform work in a manner that conforms to all appropriate Environmental Management Programs and Operational Controls identified by Installation’s EMS, including pollution prevention, waste reduction, energy use, and natural resource protection. The Contractor shall provide monitoring and measurement information as necessary for the organization to address environmental performance relative to the environmental, energy, and transportation management goals. In addition, the Contractor shall advise their employees of their roles and responsibilities identified by the EMS and how these requirements affect their work performed under this contract. The Contractor is responsible for ensuring that the Contractor and any persons involved in the supervision or performance of the contract complete all required Environmental training.

In the event of any environmental nonconformance or noncompliance associated with the contracted services, the contractor shall take corrective and/or preventative actions. In the event of any noncompliance with any federal, state, or local environmental law, regulation or requirement, the Contractor shall immediately respond by taking all appropriate corrective actions and notifying the Contracting Officer’s Representative (COR) and the Environmental Office. For any nonconformance with the EMS, the Contractor shall take corrective action and initiate further preventative action, as required by the Environmental Office.

All on-site contractor personnel shall complete necessary safety and environmental training specified for the type of work conducted on-site. Upon contract award, the COR will notify the EMS Manager to arrange Environmental training for appropriate staff.

Additionally, when ordering supplies for use on Installation, all contractor personnel must favor energy-efficient, recycled or reclaimed material whenever practicable.

The responsibilities of all contractor personnel include:

(1) Comply with all applicable environmental laws, regulations and installation environmental policies.

(2) Control and prevent spills or hazardous substances releases IAW installation Spill Prevention

Plan.

(3) Ensure dust, debris, materials, trash, etc., do not become air borne and travel off the project site.

(4) Do not remove, cut, deface, injure, or destroy land resources including trees, shrubs, vines, topsoil and land forms without approval, except in areas indicated on the drawings or specified to be cleared.

(5) Monitor all water areas affected by construction activities to prevent pollution of surface and ground waters. Do not apply toxic or hazardous chemicals to soil or vegetation unless otherwise indicated.

(6) Open burning is prohibited on the Government premises IAW installation environmental policy.

(7) Participate in installation’s recycling program.

(8) Reducing the amount of hazardous material and/or solvent used by purchasing fewer hazardous materials and by increasing the use of products with recycled content. Spills of hazardous or toxic materials must be immediately reported to the Contracting Officer and the Environmental Office.

Storage, describing, packaging, labeling, marking and placarding of hazardous waste and hazardous material IAW applicable environmental laws, regulations and local environmental policies. Transport hazardous waste off Government property and dispose of it in compliance with National, Provincial, and/or Local requirements for solid waste disposal.

(9) Reducing the amount of solid waste from construction and demolition debris, and scrap metal sent to municipal and rubble landfills by reducing, reusing, and recycling. Handling, storage, and disposal of solid waste must be conducted to prevent contamination. Transport solid waste off Government property and dispose of it in compliance with National, Provincial, and/or Local requirements for solid waste disposal.

(10) Conserving energy and water usage by turning off lights and equipment when not in use and using only the necessary amount of water needed to complete the required tasks. Continuous conservation of our natural resources is a must.

(11) When potential cultural or historic items are inadvertently found during construction activities, immediately cease activities in the vicinity of the discovery and report the findings to the Environmental Office.

(12) Participate in installation’s Integrated Pest Management (IPM) program whenever practicable.

(13) Minimize interference with disturbance to, and damage to fish, wildlife, and plants including their habitat.

Section F - Deliveries or Performance

CLAUSES INCORPORATED BY FULL TEXT

52.211-10 COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK (APR 1984)

The Contractor shall be required to (a) commence work under this contract within 10 calendar days after the date the Contractor receives the notice to proceed, (b) prosecute the work diligently, and (c) complete the entire work ready for use not later than 210 calendar days including 90 days for procurement of US origin material after notice to proceed (NTP) is issued.

* The time stated for completion shall include final cleanup of the premises.

(End of clause)

Section H - Special Contract Requirements

ANTITERRORISM/OPERATIONS SECURITY REVIEW COVER SHEET

A. AT Level I Training. This standard language is for contractor employees with an area of performance within an Army controlled installation, facility or area. All contractor employees, to include subcontractor employees, requiring access Army installations, facilities and controlled access areas shall complete AT Level I awareness training within 20 calendar days after contract start date or effective date of incorporation of this requirement into the contract, whichever is applicable. The contractor shall submit certificates of completion for each affected contractor employee and subcontractor employee, to the COR or to the contracting officer, if a COR is not assigned, within 10 calendar days after completion of training by all employees and subcontractor personnel. AT level I awareness training is available at the following website: http://jko.jten.mil.

B. Access and General Protection/Security Policy and Procedures. This standard language is for contractor employees with an area of performance within Army controlled installation, facility, or area. Contractor and all associated sub-contractors employees shall provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.

B-a. For contractors that do not require CAC, but require access to a DoD facility or installation.

Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014-05/AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.

C. iWATCH Training. This standard language is for contractor employees with an area of performance within an Army controlled installation, facility or area. The contractor and all associated sub-contractors shall brief all employees on the local iWATCH program (training standards provided by the requiring activity ATO). This local developed training will be used to inform employees of the types of behavior to watch for and instruct employees to report suspicious activity to the COR. This training shall be completed within 10 calendar days of contract award and within 10 calendar days of new employees commencing performance with the results reported to the COR NLT 10 calendar days after contract award.

D. Requirement for OPSEC Training. Per AR 530-1 Operations Security, the contractor employees must complete Level I OPSEC Awareness training. New employees must be trained within 30 calendar days of their reporting for duty and annually thereafter.

OPSEC training is available at the following website: http://cdsetrain.dtic.mil/opsec/

Section J - List of Documents, Exhibits and Other Attachments

LIST OF APPLICABLE CONTRACT DRAWINGS

GENERAL: The work shall conform to the following contract drawings and OMA standard detail drawings, 2014 (dated 30 November 2015), issued by the Department of the Army, Installation Management Agency, Korea Region Office and located on http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/STANDARD- DETAIL-DRAWINGS-FOR-OMA-PROJECTS-KOREA_20151130.pdf, all of which form a part of the specifications.

Ring No. Sheet No. Description Date

1 T-1 TITLE SHEET 19 MAY 17

CIVIL

2 C-1 LOCATION PLAN AND GENERAL NOTES 19 MAY 17

3 C-2 SITE LAYOUT PLAN AND SCOPE OF WORK 19 MAY 17

4 C-3 MISC. DETAILS-1 19 MAY 17

5 C-4 MISC. DETAILS-2 19 MAY 17

ARCHITECTURAL

6 A-1 1ST FLOOR PLAN & GENERAL NOTES 19 MAY 17

7 A-2 2ND-4TH FLOOR PLAN & SCOPE OF WORKS 19 MAY 17

8 A-3 EXT/INTERIOR WALL SECTIONS AND SCOPE OF

WORKS

19 MAY 17

9 A-4 PICTURE AND DETAILS 19 MAY 17

10 A-5 TYPICAL & PARTIAL PLANS AND ELEVATIONS 19 MAY 17

11 A-6 DETAILS 19 MAY 17

12 A-7 CABINET DETAILS AND NOTES 19 MAY 17

13 A-8 INTERIOR, EXTERIOR FINISH SCHEDULE AND

MATERIAL & COLOR SCHEDULE

19 MAY 17

14 A-9 DOOR / WINDOW SCHEDULE, ELEVATIONS AND

NOTES

19 MAY 17

15 A-10 HARDWARE SCHEDULE AND DETAILS 19 MAY 17

16 A-11 SIGNAGES SCHEDULE 19 MAY 17

MECHANICAL

17 M-1 MECHANICAL MATERIAL INDICATIONS & SYMBOLS

AND ABBREVIATIONS

19 MAY 17

18 M-2 GENERAL NOTES AND SCOPE OF WORK 19 MAY 17

19 M-3 MECHANICAL EQUIPMENT SCHEDULE-1 19 MAY 17

20 M-4 MECHANICAL EQUIPMENT SCHEDULE-2 19 MAY 17

21 M-5 1ST FL HVAC PLAN, AIR DEVICE SCHEDULE AND

NOTES

19 MAY 17

22 M-6 2ND FL HVAC PLAN AND NOTES 19 MAY 17

23 M-7 3RD FL HVAC PLAN AND NOTES 19 MAY 17

24 M-8 4TH FL HVAC PLAN AND NOTES 19 MAY 17

25 M-9 MECH RM HVAC PARTIAL PLAN, EXHAUST DUCT

ISOMETRIC DIAGRAM (TYP) AND NOTES

19 MAY 17

26 M-10 LAUNDRY RM HVAC PARTIAL PLAN(TYP), TYP

MODULE HVAC PARTIAL PLAN (1ST THRU 4TH FL)

AND ISOMETRIC DIAGRAM

19 MAY 17

27 M-11 CONTROL AND CHILLED/HOT WATER PIPING SYSTEM

DIAGRAM

19 MAY 17

28 M-12 OUTSIDE AIR SUPPLY UNIT SINGLE ZONE, FCU

CONTROL DIAGRAM AND CO DETECTION SYSTEM

19 MAY 17

29 M-13 VENT SYS CONTROL DIA, DOMESTIC HOT WATER

SYSTEM CONTROL DIAGRAM, EF-4 AND EF-1

CONTROL CIRCUIT(TYP FOR EF-5) AND CO

DETECTION SYSTEM

19 MAY 17

30 M-14 1ST & 2ND FL PLUMBING PIPING PLAN, SPECIFIC

NOTES AND NOTES

19 MAY 17

31 M-15 3RD & 4TH FL PLUMBING PIPING PLAN, SPECIFIC

NOTES AND NOTES

19 MAY 17

32 M-16 MECH ROOM PLUMBING PARTIAL PLAN AND NOTES 19 MAY 17

33 M-17 TYP MODULE PLUMBING PARTIAL PLANS-1 AND 2

AND NOTES

19 MAY 17

34 M-18 LAUNDRY PLUMBING PARTIAL PLANS AND NOTES 19 MAY 17

35 M-19 TOILET PLUMBING PARTIAL PLANS, PLUMBING

FIXTURE SCHEDULE AND NOTES

19 MAY 17

36 M-20 FIRE PROTECTION LEGEND & ABBREVIATION

SPRINKLER Q'TY LIST AND GENERAL NOTES

19 MAY 17

37 M-21 1ST FLOOR FIRE PROTECTION PIPING PLAN 19 MAY 17

38 M-22 2ND FLOOR FIRE PROTECTION PIPING PLAN 19 MAY 17

39 M-23 3RD FLOOR FIRE PROTECTION PIPING PLAN 19 MAY 17

40 M-24 4TH FLOOR FIRE PROTECTION PIPING PLAN 19 MAY 17

41 M-25 MECH ROOM FIRE PROTECTION PIPING PARTIAL

PLAN, SECTION AND FIRE PROTECTION

REQUIREMENT

19 MAY 17

42 M-26 DETAILS-1 19 MAY 17

43 M-27 DETAILS-2 19 MAY 17

ELECTRICAL

44 E-1 LEGEND, GENERAL NOTES AND SCOPE OF WORKS 19 MAY 17

45 E-2 EXIST/NEW EXTERIOR COMMUNICATION LINE

DISTRIBUTION PLAN

19 MAY 17

46 E-3 1ST, 2ND, 3RD AND 4TH FLOOR LIGHTING PLAN 19 MAY 17

47 E-4 LIGHTING FIXTURE DETAILS 19 MAY 17

48 E-5 LIGHTING FIXTURE SCHEDULE 19 MAY 17

49 E-6 1ST, 2ND, 3RD & 4TH FLOOR POWER PLAN 19 MAY 17

50 E-7 PANELBOARD "P" & LOAD CENTER "L1","L2","L3 &"L4"

LOAD SCHEDULE

19 MAY 17

51 E-8 TYPICAL BEDROOM ELECTRICAL MODULE PLAN &

MECH. RM PARTIAL POWER PLAN

19 MAY 17

52 E-9 1ST, 2ND, 3RD & 4TH FLOOR LAN/TEL PLAN 19 MAY 17

53 E-10 TELECOMMUNICATION SYSTEM DIAGRAM 19 MAY 17

54 E-11 1ST, 2ND, 3RD AND 4TH FLOOR CATV PLAN 19 MAY 17

55 E-12 CATV SYSTEM DIAGRAM 19 MAY 17

56 E-13 1ST, 2ND, 3RD & 4TH FLOOR FIRE ALARM AND MASS

NOTIFICATION SYSTEM PLAN

19 MAY 17

57 E-14 FIRE ALARM / MASS NOTIFICATION SYSTEM

DIAGRAM

19 MAY 17

SUBMITTAL REGISTER

NOTE 1. See the attachment.

NOTE 2. The Submittal Register in Section J above, identifies the documentation that will be made available for approval and review by the Government in the performance of this task order. It is the contractor's responsibility that this data is in compliance with the corresponding OMA specification that is referenced.

Section K - Representations, Certifications and Other Statements of Offerors

52.203-2 CERTIFICATE OF INDEPENDENT PRICE DETERMINATION (APR 1985)

(a) The offeror certifies that --

(1) The prices in this offer have been arrived at independently, without, for the purpose of restricting competition, any consultation, communication, or agreement with any other offeror or competitor relating to –

(i) Those prices,

(ii) The intention to submit an offer, or

(iii) The methods of factors used to calculate the prices offered:

(2) The prices in this offer have not been and will not be knowingly disclosed by the offeror, directly or indirectly, to any other offeror or competitor before bid opening (in the case of a sealed bid solicitation) or contract award (in the case of a negotiated solicitation) unless otherwise required by law; and

(3) No attempt has been made or will be made by the offeror to induce any other concern to submit or not to submit an offer for the purpose of restricting competition.

(b) Each signature on the offer is considered to be a certification by the signatory that the signatory --

(1) Is the person in the offeror's organization responsible for determining the prices offered in this bid or proposal, and that the signatory has not participated and will not participate in any action contrary to subparagraphs (a)(1) through (a)(3) of this provision; or

(2) (i) Has been authorized, in writing, to act as agent for the following principals in certifying that those principals have not participated, and will not participate in any action contrary to subparagraphs (a)(1) through (a)(3) of this provison ______________________________________________________ (insert full name of person(s) in the offeror's organization responsible for determining the prices offered in this bid or proposal, and the title of his or her position in the offeror's organization);

(ii) As an authorized agent, does certify that the principals named in subdivision (b)(2)(i) above have not participated, and will not participate, in any action contrary to subparagraphs (a)(1) through (a)(3) above; and

(iii) As an agent, has not personally participated, and will not participate, in any action contrary to subparagraphs (a)(1) through (a)(3) of this provision.

(c) If the offeror deletes or modifies subparagraph (a)(2) of this provision, the offeror must furnish with its offer a signed statement setting forth in detail the circumstances of the disclosure.

(End of Provision)

252.209-7999 Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony Conviction under any Federal Law

REPRESENTATION BY CORPORATIONS REGARDING AN UNPAID DELINQUENT TAX LIABILTIY

OR A FELONY CONVICTION UNDER ANY FEDERAL LAW (DEVIATION 2012-00004) (JAN 2012)

(a) In accordance with sections 8124 and 8125 of Division A of the Consolidated Appropriations Act, 2012, (Pub. L. 112-74) none of the funds made available by that Act may be used to enter into a contract with any corporation that-

(1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless the agency has considered suspension or debarment of the corporation and made a determination that this further action is not necessary to protect the interests of the Government.

(2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless the agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government.

(b) The Offeror represents that –

(1) It is ( ) is not ( ) a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with authority responsible for collecting the tax liability,

(2) It is ( ) is not ( ) a corporation that was convicted of a felony criminal violation under a federal law within the preceding 24 months.

(End of provision)

5152.204-4032 REPRESENTATIONS AND CERTIFICATIONS

(a) SUBCONTRACTING:

If the offeror contemplates subcontracting, it must obtain prior written approval of subcontractor from the PCO or ACO, and list below: (1) the names and addresses of the subcontractor(s), (2) the type of subcontracting, and (3) the estimated price for each subcontract.

(b) AFFILIATED OFFERORS:

(1) Business concerns are affiliates of each other when, either directly or indirectly, one concern controls or has the power to control the other, or a third party controls or has the power to control both.

(2) Each offeror shall furnish, below, the following information:

(i) Whether the offeror has any affiliates;

(ii) The names and addresses of all affiliates of the offeror; and

(iii) The names and addresses of all persons and concerns exercising control or ownership of the offeror and any or all of its affiliates, and whether they are common officers, directors, stockholders holding controlling interest, or otherwise.

AFFILIATED CONCERNS. : (Name, location and, in detail, controlling interest in each)

(c) PRINCIPAL OWNER(S) OR STOCKHOLDER(S):

Each offeror shall list below the name(s) and address(es) of the principal owner(s) or stockholder(s) of the company and percentage of ownership. If a major portion is publicly traded and/or otherwise widely distributed, state that, with the percentage so affected.

(d) STANDARDS OF CONDUCT CERTIFICATION:

This is to certify that, to the best of my knowledge and belief, except as described below, no representative of this firm who deals with US Government employees on any aspect of this procurement is a former US Government employee, to include former US military personnel. I understand that this certification is continuing in nature and places a duty on me and my firm to notify the Contracting Officer of any additional individual(s) who fit the above description prior to the individual's assuming duties.

(i) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

(ii) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

(iii) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

Firm ____________________________________________________ Name _____________________________________________________ Signature __________________________________________________

Title _____________________________________________________ Date of Execution ____________________________________________

(e) TAXES:

(1) References:

(i) Contract clause entitled "FAR 52.229-06 Taxes—Foreign Fixed-Price Contracts (Jan 1991)."

(ii) US-ROK Status of Forces Agreement (SOFA), Articles IX and XVI.

(iii) ROK Customs Law, Law No. 1976, promulgated on 29 November 1967, as amended.

(iv) ROK Value Added Tax Law, Law No. 2934, promulgated on 22 December 1976 (effective date 1 July 1977), as amended.

(v) ROK Special Excise Tax Law, Law No. 2935, promulgated on 22 December 1976 (effective date 1 July 1977), as amended.

(2) Contractor shall state the types and estimated amount of taxes that would normally apply to such transactions but are excluded from this proposal.

(i) Customs Tax (except for ROK MND-funded contracts or delivery orders):

Name Number Cost/Unit of Item of Units w/o Tax % of Tax Tax/Unit Tax Total

This item will be imported specifically for this contract? Yes _____ No _____

(ii) Special Excise Tax:

Name Number Cost/Unit of Item of Units w/o Tax % of Tax Tax/Unit Tax Total

Name of item manufacturer

(iii) Value Added Tax (VAT):

Input VAT on materials purchased for this contract. 10% _____ Input VAT on transportation leased/rented for this contract.10% _____ Input VAT on equipment leased/rented for this contract. 10% _____ Input VAT on services purchased for this contract. 10% _____ Output VAT on total contract amount. 10% _____

(iv) Special Excise (Petroleum) Tax:

No. of U/P Liters w/o Tax Tax/Unit Total Tax Amount Regular Gasoline ________ (L) ________ w________ w_____________ Premium Gasoline ________ (L) ________ w________ w_____________ Diesel ________ (L) ________ w________ w_____________ Other ________ (L) ________ w________ w_____________

(v) Education Tax.

(3) Name of the oil company from which POL products will be purchased:

Oil Company: _________________________________________ (Name only)

(4) I certify by this submission that all supplies and services to be purchased for this contract have been proposed exclusive of Value Added Tax, applicable Customs Tax (except ROK MND-funded contracts and delivery orders), Special Excise Tax, and Education Tax.

Signed (Chop)

(f) CERTIFICATIONS AND REPRESENTATIONS

By submitting an offer, each offeror agrees to be bound by all certifications and representations in this solicitation.

The Government reserves the right to require any and all certifications and representations to be completed and signed in hard copy by the successful offeror prior to contract award. Failure of an offeror to complete the certifications and representations within the time directed by the Contracting Officer may result in a determination that the contractor is not a responsible offeror for this acquisition.

Section L - Instructions, Conditions and Notices to Bidders

SECTION L

1. GENERAL INSTRUCTIONS FOR PREPARATION OF PROPOSAL:

The Government intends to award without discussion, but reserves the right to conduct discussions if deemed necessary and to establish a competitive range for efficiency in accordance with FAR 52.215-1(f)(4).

Offeror(s) may, at the discretion of the Government, be asked to provide more information and clarification regarding their proposals. The Government may make a final determination as to whether an offer is acceptable or unacceptable solely based on the proposals as submitted, without requesting any further information. However, if it is deemed necessary the Government may, at its sole discretion, request additional information clarifying but not substantially changing any proposal as submitted.

2. SUBMISSION OF PROPOSAL:

i) FBO SUBMISSION REQUIRED: Offers shall be submitted to the Federal Business Opportunities (FBO) website (https://www.fbo.gov/), or if FBO is not available, email to ukap.son1.ln@mail.mil with the evidence document such as screen shot. The FBO unavailability is limited to only FBO server problem not individual failure/problem.

All questions should be emailed to ukap.son1.ln@mail.mil within five (5) days after the solicitation is issued.

ii) CLOSING DATE: The electronic offer shall be submitted by 1500 hours, KST on the closing date of RFP.

iii) SUBMISSION REQUIREMENTS

a) PRICING PROPOSAL: The pricing proposal must clearly indicate prices for each Contract Line Item Number in Section B - Supplies or Services and Prices.

b) DETAILED OFFER BREAKDOWN: The detailed offer breakdown must clearly identify all costs that can materially impact the statement of work.

c) SECTION K - Representations, Certifications and Other Statements of Offerors SECTION K-TAXES: Offerors must complete all tax portions of SECTION K. The offeror shall review all expenses to ensure that all applicable taxes are excluded from the overall price. In addition, offerors shall propose exemptions of specific ROK taxes that are legitimate, attributable to the contract, and authorized by the applicable stated references.

SECTION K-OTHER: Offerors must complete all Non-Tax related portions of SECTION K.

iv) COMPLIANCE WITH SOLICITATION: Failure to submit the above requirements under SECTION L may be grounds for determining the proposal to be non-compliant. For example, if a detailed offer breakdown is not submitted, the contracting officer will be unable to find the offeror's pricing proposal acceptable and the offeror's proposal will be ineligible for award. Non-compliance will only be cured if the government holds discussions as detailed in SECTION L.

52.236-27 SITE VISIT (CONSTRUCTION) (FEB 1995) – ALTERNATE I (FEB 1995)

(a) The clauses at 52.236-2, Differing Site Conditions, and 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation. Accordingly, offerors or quoters are urged and expected to inspect the site where the work will be performed.

(b) An organized site visit has been scheduled for--

Date and Time : 30 May 18, 1000 hours POC : So, Ki Chong, DSN: 730‐3713, Cell: 010‐2718‐7476 Location : Room No. 424, Building No. 2409, Camp Casey

Anyone who wants to attend the site visit should notify CONTRACT SPECIALIST NO LATER THAN 29 May 18, 1300 hours in advance. The site visit will be canceled if no one has notified.

(End of provision)

5152.236-4011 CONSTRUCTION PRICE RANGE

Pursuant to FAR 36.204 the estimated price range is between $ 1,000,000 and $5,000,000.

Section M - Evaluation Factors for Award

BASIS OF AWARD

Electronic offers submitted by 1500 hours, KST on the closing date of RFP shall be considered timely.

i) EVALUATION CRITERIA The pricing proposal shall be evaluated to determine whether it is complete and reasonable. A complete and reasonable pricing proposal will be deemed acceptable.

The detailed offer breakdown will be used by the contracting officer to determine whether proposed prices are complete and reasonable. A detailed offer breakdown may be used by the contracting officer to determine whether an offeror is able to complete the requirements under the contract, and/or whether discussions will be conducted pursuant to instructions to the offerors.

ii) SECTION K - Representations, Certifications and Other Statements of Offerors

a. SECTION K-TAXES will be evaluated to determine whether it is complete. In addition, propose exemptions of specific ROK taxes will be evaluated to determine whether they are legitimate, attributable to the contract, authorized, and reasonable. A complete SECTION-K that only proposes exemptions of specific ROK taxes that are legitimate, attributable to the contract, necessary to complete the Task Order, do not improperly overstate any proposed tax exemption, authorized, and reasonable will be deemed acceptable.

b. SECTION K-OTHER will be evaluated to determine whether it is complete. A complete SECTION K-OTHER will be deemed acceptable.

BASIS FOR AWARD: Award shall be made to the responsible offeror submitting the lowest priced offer that is evaluated as acceptable for all evaluation criteria.

File details come from the government source that posted it.