M-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

MECHANICAL MATERIAL INDICATIONS &

M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S

NTS

PD

Pa

OS&Y

OXY

OD

OAIL

OA

QT

PRV

PPM

POL

POC

PLMB

PH

PG

RT

RPM

RH

RDTR

RA

R12, R22

QTY

A B B R E V I A T I O N S

SBM

SAN

SA

SCH

FLOWMETER, ORIFICEBUTTERFLY

REFRIGERANT LIQUID

CHILLED WATER SUPPLY

CHILLED WATER RETURN

AIR COOLED CONDENSING UNIT

AIR CONDITION UNIT (S)

APPARATUS DEW POINT

AIR CONDITION (-ING,-ED)

CHILLED/HOT WATER RETURN

AMERICAN WIRE GAUGE

PRESSURE, BAROMETRIC

CUBIC METER PER HOUR

CHILLED/HOT WATER SUPPLY

CAPACITYCAP

CONNECTION

CONTINUE

COMPRESSOR

CUBIC METER

CPRSR

CONN

CONT

CU M

CHILLED WATER

CAST IRON PIPE

CIRCUIT

CLASSIFICATION

COOLING LOAD

COEFFICIENT

COUNTER CLOCKWISE

CLASS

CLG LOAD

COEF

CMH

CIP

CCW

CHW

CKT

ACV ALARM CHECK VALVE

AVERAGEAVG

BOILING POINT

CENTIGRADE

BAROMETER(-TRIC)

BRAKE HORSEPOWER

BP

BHP

C

BARO PR

AWG

BARO

ALUMINUM

ALTITUDE

AMBIENT

AIR HANDLING UNIT

AMPERE(AMP, AMPS)

APPROXIMATEAPPROX

ALT

AMB

AMP

AIR COND

ADP

AL

AHU

AIR COOLED

ACCU

ACLD

ACU

CHR

C/HWR

C/HWS

CHS

RL

D DRAIN

DIAMETER, INSIDE

ISOMETRIC

IRON PIPE SIZE

JOULE

THERMAL CONDUCTIVITY

KILOGRAM

KILOGRAM PER SQ. CENTIMETER (GAUGE)

KILOGRAM PER SQ. CENTIMETER

KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)

KILOCALORIE PER HOUR

EXPANSION JOINT

EXPLOSION PROOF

FIRE HOSE CABINET

FULL LOAD AMPERES

ENTERING WATER TEMP

EVAPORAT (-E,-ING,-ED,-OR)

EXTERNAL STATIC PRESSURE

FACE AREA OR FRESH AIRFA

FHC

FHY

FLA

FIRE HYDRANT

ESP

EXPJT

EWT

EVAP

EP

EQPT

ENT

EFF

EQUIPMENT

ENTERING

EFFICIENCY

KG/SQ CM

KG/SQ CM A

KG/SQ CM G

KG

KCAL/HR

J

K

ID

ISO

IPS

NO

N.O.

NIC

NPT

MPS

NC

N/A

N.C.

MAX

MIN

MPH

MM

NOT IN CONTRACT

NATIONAL TAPER PIPE (THREAD)

NUMBER

NORMALLY OPEN

MINIMUM OR MINUTE

METERS PER HOUR

METERS PER SECOND

NORMALLY CLOSED

NOISE CRITERIA

NOT APPLICABLE

MAXIMUM

MILLIMETER R

FEMALE PIPE THREAD

FUEL OIL

GALVANIZED STEEL

GAGE OR GAUGE

FIXTURE

FEED WATER PUMP

FACE VELOCITY

FLUSH VALVE

FREQUENCY

FIBERGLASS REINFORCED PLASTIC

HORIZONTAL

HOT WATER HEATER

HOT WATER

HOUR(S)

HORSEPOWER

MERCURY

HEAD

HOSE BIBB

HERTZ

GRAMS

FRPCWP CIRCULATING WATER PUMP

DIRECT EXPANSION

DRY PIPE VALVE

EQUIVALENT DIRECT RADIATION

ENTERING AIR TEMPERATURE

DOUBLE POLE DOUBLE THROW

DEWPOINT TEMPERATURE

DRY BULB TEMPERATURE

DECIBEL OR DRY BULB

DIESEL OILDO

ECON

ECC

EAT

EDR

DX

DPV

DPDT

DPT

ECONOMIZER

ECCENTRIC

o

DEG or °

DIFF

DIAG

DIA or

DIV

DBT

DB

DIFFERENCE

DIAGRAM

DIAMETER

DIVISION

DEGREE

HR

HORIZ

HWH

HW

HZ

HP

HG

HD

HB

GALVS

GA

GR

FXTR

FWP

FVEL

FV

CUBIC MILLIMETER

CLOCKWISE OR COLD WATER

COEFFICIENT, VALVE FLOWCv

CU MM

CW

PLUG VALVE

THREE WAY

FPT

FO

FREQ

GATE, ANGLE

GATE, GLOBE

GLOBE

GATE

CONTROL

KJ KILOJOULE

LH

LT

LWT

LPS

M

LL

LPD

LPH

LM

LAV

LAT

LBS

LG

KW

KWH

L

LATENT HEAT

LEAVING WATER TEMPERATURE

LITERS PER HOUR

LITERS PER SECOND

LAUNDRY TRAY

METERS

LIQUID LINE

LITERS PER DAY

LINEAR METER

LEAVING AIR TEMPERATURE

LAVATORY

POUNDS

LENGTH

KILOWATT

KILOWATT HOUR

LITERS

P

FLOWMETER, VENTURI

FLOW SWITCH

PRESSURE SWITCH

PRESSURE GAUGE AND COCK

PUMP (INDICATE USE)

STRAINER

STRAINER, BLOW OFF

KG/SM

KG/SM A

KG/SM G

PS

P

OFM

FS

VFM

KILOGRAM PER SQ. METER

KILOGRAM PER SQ. METER (ABSOLUTE)

KILOGRAM PER SQ. METER (GAUGE)

JACKET WATER RETURN

MEDIUM PRESSURE STEAM

MEDIUM PRESSURE CONDENSATE

LOW PRESSURE STEAM

LOW PRESSURE CONDENSATE

BOILER BLOW DOWN

PUMPED CONDENSATE

JACKET WATER SUPPLY

VACUUM PUMP DISCHARGE

FUEL OIL TANK VENT

CONDENSATE WATER SUPPLY

CONDENSATE WATER RETURN

MEDIUM TEMPERATURE HOT WATER SUPPLY

MEDIUM TEMPERATURE HOT WATER RETURN

LOW TEMPERATURE HOT WATER SUPPLY

LOW TEMPERATURE HOT WATER RETURN

PIPE TO BE REMOVED

REFRIGERANT DISCHARGE

REFRIGERANT SUCTION

LPS

CONTROL AIR MAIN

air conditioning and refrigeration

RD

RS

(NAME)E

(NAME)

M

EXISTING PIPE

COMPRESSED AIR

VACUUM (AIR)

HWR

VAC

A

MTWS

MTWR

HWS

FOD FUEL OIL DRAIN

FOR

CS

CR

FOV

FOG

FOS FUEL OIL SUPPLY

FUEL OIL RETURN

FUEL OIL GAUGE

PC

VPD

MU

LPC

BBD

MAKE UP WATER

MPS

MPC

JWR

JWS

heating

PIPING

CHECK, SWINGSANITARY DRAIN

PITCH OR PIPE, UP(U), DOWN(D)

FLOOR SINK (200mm x 200mm)

PIPE SLEEVE WITH FIRE STOPPING

VENT THRU ROOF

BFP

60°C

82°C valves : (for selective actuators)

PLAN

HOT WATER (82°C)

HOSE BIBB

AIR LINEA

BALL

ELEV.

HOT WATER (60°C)

BACKFLOW PREVENTER

PIPE SLEEVE

(NAME)

ACID

200mm x 200mm

SURFACE CLEANOUT

FLOOR CLEANOUT

FLOOR DRAIN

CHEMICAL SUPPLY PIPES

FUNNEL DRAIN, OPEN

FCO

FD

SCO

FLOOR OR GRADE

FLOOR OR GRADE

CONDENSATE DRAIN BELOW

CONDENSATE DRAIN ABOVE

ACID WASTE

GASG

CD

CD

AIR VENT, MANUAL

AIR VENT, AUTOMATIC

W/ MEASURING TAP

EXPANSION LOOP

EXPANSION JOINT

BALL JOINT

ANCHOR, MAIN

ANCHOR, INTERMEDIATE

ALIGNMENT GUIDE

AIR SEPARATOR

FLEXIBLE CONNECTOR

SQUARE HEAD BALANCING COCK

EJ

S

MV

AVV

CHECK, NON-SLAM

CONTROL, ELECTRIC-PNEUMATIC

CONTROL, PNEUMATIC-ELECTRIC

QUICK OPENING

PRESSURE REDUCING

NEEDLE

LOCK SHIELD

HOSE END DRAIN

SAFETY

RELIEF

SQUARE HEAD BALANCING COCK

QUICK CLOSING, FUSIBLE LINK

R

S

PE

EP

plumbing

COLD WATER

HOT WATER RETURN

HOT WATER SUPPLY

VENT

MOTOR ELECTRIC

DIAPHRAGM

valves, special duty :

SOLENOIDS

valve actuators

M

FDAD

SUCTIONQUANTITY SUCT

TONS OF REFRIGERATION

TEMPERATURE DIFFERENCE

HEAT TRANSFER COEFFICIENT

SANITARY

SUBMERSIBLE

SUPPLY AIR

SCHEDULE

RADIATOR

REFRIGERATION TON

REVOLUTIONS PER MINUTE

RELATIVE HUMIDITY

RETURN AIR

THERMAL RESISTANCE

REFRIGERANT (12, 22, ETC)

TYPICALTYP

URINAL

UNIT HEATER

UR

UH

U

THERMOSTAT

THICKNESS

THERMOMETER

TEMPERATURE

SYMBOL

TSTAT

TONS

THERM

THK

TEMP

TD

SYM

SINGLE POLE DOUBLE THROW

LPH, STANDARD CONDITIONS

LPS, STANDARD CONDITIONS

LPD, STANDARD CONDITIONS

SAYBOLT SECONDS UNIVERSAL

SAYBOLT SECONDS FUROL

SENSIBLE HEATOUTSIDE AIR INTAKE LOUVER SH

PRESSURE DROP OR DIFFERENCE

PRESSURE REDUCING VALVE

PHASE (ELECTRIC)

PERCENT

PARTS PER MILLION

POINT OF CONNECTION

PLUMBING

PETROLEUM, OIL AND LUBRICANTS

QUART

OUTSIDE SCREW & YOKE

DIAMETER, OUTSIDE

PRESSURE GAGE

POLE

PASCAL

OXYGEN

SPRINKLERSPR

STEEL

STANDARD

STEAM

SQUARE

STAINLESS STEEL

STORAGESTOR

STL

STD

ST

SSU

SST

SSF

SQ

SENSIBLE LOAD

STATIC PRESSURE

SQUARE METER

SPECIFICATION

SPDT

SPEC

SM

SP

SLPH

SLPS

SLPD

SL

ALARM CHECK VALVE

SIDEWALL SPRINKLER

PENDENT SPRINKLER

UPRIGHT SPRINKLER

FIRE DEPARTMENT CONNECTION

PRE-ACTION VALVE

NOT TO SCALE

OUTSIDE AIR

(2-WAY SHOWN)

DRY-PIPE VALVE

SECOND

SAFETY FACTOR

SPECIFIC GRAVITYSG

SF

SEC

VARIABLE AIR VOLUMEVAV

VENTILATION

PRESSURE, DYNAMIC(VELOCITY)

WATER-COOLED

WATER CLOSET

WATTHOUR OR WATER HEATER

WET BULB TEMPERATURE

WATERPROOF

WSHR

WCLD

WTRPRF

WH

WT

W/

WD

WC

WBT

WEIGHT

WITH

WASHER

WIDTH

VP

VOL

WB

W

VISC

VERT

VENT

VEL

VOLUME

WET BULB

WATT

VISCOSITY

VERTICAL

VELOCITY

MANUAL VOLUME DAMPER

SMOKE DAMPER (PROVIDE ACCESS DOOR)

PNEUMATIC OPERATED DAMPER

VLV

V

VAC

M

VALVE

VOLT

VACUUM

SPLITTER DAMPER

SD

AD

VD

grilles, registers and diffusers :

SG

SR

600/300

300x150

200mm NCD

FIGURE IS ON TOP

810mm x 400mm dampers

ELBOW, TURNED DOWN

REDUCER, CONCENTRIC

REDUCER, ECCENTRIC (STRAIGHT, INVERT)

REDUCER, ECCENTRIC (STRAIGHT, DOWN)

TEE, OUTLET DOWN

TEE, SINGLE SWEEP

sprinkler

UNION, SCREWED

UNION, FLANGED

TEE, OUTLET UP

TEE

LATERAL

CONNECTION, BOTTOM

CONNECTION, TOP

ELBOW, TURNED UP

BUSHING

ELBOW, 45°

ELBOW, 90°

CAP

WELDED

FLANGED

SOLDERED

SCREWED BELL AND SPIGOT

SOLVENT CEMENT

SOUND ATTENUATOR

DETECTORS, FIRE AND/OR SMOKE

ELECTRIC MOTOR OPERATED DAMPER

FIRE DAMPER (PROVIDE ACCESS DOOR)

BACKDRAFT DAMPER

BDD

S

TRANSITION

TURNING VANES

SF

CHANGE OF ELEVATION, RISE(R), DOWN(D)

DUCT SECTION, NEGATIVE PRESS., FIRST

ACCESS DOOR, VERTICAL OR HORIZONTAL

COWL, (GOOSENECK) AND FLASHING

ACOUSTICAL LINING

FLEXIBLE DUCT

FLEXIBLE CONNECTIONFC

FIGURE IS ON TOP

R

AD

47.2

TG

94.4

UC 13mm

DG

500/300L

DUCT WORK

810mm x 400mm

810mm x 400mm

THERMOSTAT, ELECTRIC

TRAP, ELECTRIC (INDICATE TYPE)

fitting :

R

THERMOMETER

EXHAUST AIR GRILLE OR REGISTER, CEILING

DUCT SECTION, POSITIVE PRESS., FIRST

DIRECTION OF FLOW

SR

DIFFUSER, LINEAR

RETURN AIR GRILLE OR REGISTER, CEILING

CEILING DIFFUSER, SQUARE TYPE

CEILING DIFFUSER, ROUND TYPE (200mm

(600mm x 300mmH, 472 LPS)

UNDERCUT DOOR (13mm, 47.2 LPS)

DOOR GRILLE (300mmx150mmH)

NECK DIAMETER)

TRANSFER GRILLE ASSEMBLY

LOUVER, DOOR OR WALL

(500mmWx300mmH, 94.4 LPS)

RG

RR

SUPPLY AIR GRILLE OR REGISTER, SIDEWALL

EXHAUST AIR GRILLE OR REGISTER, CEILING

SUPPLY AIR GRILLE OR REGISTER, CEILING

ER

SG

EG

EXISTING WORK TO BE REMOVED.

POINT OF CONNECTION NEW TO EXISTING

OR END OF DEMOLITION WORK

EXISTING WORK TO REMAIN.(E)

REMOVE EXIST WORK.(R)

1 5

SYMBOLS AND ABBREVIATIONS

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

M-2

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

GENERAL NOTES & SCOPE OF WORK

5. CONCRETE REMOVAL AND RESTORATION SHALL CONFORM TO SPECIFICATION.

NECESSARY DUCT CONNECTION(S) TO FUNCTION AS ORIGINALLY INTENDED.

12. PRIOR TO INSTALLING NEW HVAC AND PLUMBING PIPING CONTRACTOR MUST

COORDINATE WITH EXISTING DUCTWORK AND PIPING ELEVATION/LOCATION.

IF EXISTING DUCT ELEVATION IS CONFLICTED WITH NEW PIPING INSTALLATION,

REMOVE EXISTING DUCTWORK AND INSTALL NEW DUCTWORK AND MAKE ALL

CONTRACTING OFFICER FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE

FIELD CONDITIONS. SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE

11. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT

SUCH AS ANCHORS, HANGERS/SUPPORT, ETC.

10. ALL HVAC PIPING/DUCTWORK TO BE REMOVED SHALL INCLUDE ALL IT'S ACCESSORIES

9. ANY OPENING RESULT FROM THE REMOVAL WORK THAT'S NOT TO BE RE-USED

SHALL BE PATCHED OR RESTORED TO MATCH ADJACENT SURFACE OR AREA.

GENERAL NOTES

PER SPEC.

THIS CONTRACTOR.

AND SHALL BE VERIFIED AT THE JOB SITE.

CORRECTIONS FOR CONTRACTING OFFICER'S APPROVAL.

7. ALL WALL/FLOOR/ROOF OPENINGS RESULTED FROM THE REMOVAL OF PIPING AND

4. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED

6. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWINGS.

SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.

2. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. APPROXIMATE

OFFICER'S REPRESENTATIVE ATTENTION WITH RECOMMENDATIONS FOR PROPER

IF ANY DISCREPANCY IS DETECTED, IT SHOULD BE BROUGHT TO THE CONTRACTING

THE EXISTING CONDITIONS, EQUIPMENT, FINISHES, ETC., PRIOR TO START OF WORK.

1. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH

THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED OR REPLACED BY

THE EXISTING EQUIPMENT ANY EQUIPMENT, DUCT WORK, PIPING ETC. DAMAGED DUE TO

3. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE

THE REQUIREMENTS OF SEAL CLASS C.

8. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED

ACCORDING TO SMACNA STATIC PRESSURE CALSS 500PA AND DUCTWORK SHALL MEET

DUCTWORK SHALL BE PATCHED OR RESTORED TO MATCH ADJACENT SURFACE OR AREAS.

SCOPE OF WORK

13.

CHANGES REQUIRED TO MAKE THIS

CONTRACTOR SHALL PROVIDE NECESSARY SHOP DRAWINGS FOR ANY

REQUIREMENT FOR GAS ONLY BURNERS MAY BE JUSTIFIABLE. THE

PACKAGE, PRIOR TO THE START OF CONSTRUCTION, THEREFORE THE

PROVIDE NATURAL GAS ACCESS TO THE BUILDING UNDER THIS DESIGN

CONCURRENT NATURAL GAS CONVERSION PROJECT PACKAGES MAY

HEATING SYSTEMS WITH DPW PRIOR TO THE START OF CONSTRUCTION.

AND OIL) BURNERS FOR HEATING HOT WATER AND DOMESTIC HOT WATER

THE CONTRACTOR SHALL COORDINATE THE USAGE OF DUAL FUEL (GAS

SPRINKLER WORK

REPAIR AND MAINTENANCE WORK

HVAC SYSTEM

ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY THE CONTRACTOR IN STRICT ACCORDANCE WITH

APPLICABLE SECTIONS OF DIVISION 15 - MECHANICAL O&MA STANDARD TECHNICAL SPECIFICATIONS FOR MISCELLANEOUS PROJECTS, KOREA.

THE HVAC TESTING, ADJUSTING, AND BALANCING (TAB) REPORT SHALL BE SUBMITTED TO THE PROJECT COR FOR GOVERNMENT REVIEW AND

APPROVAL.

1.

2.

5.

6.

7.

8.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED BATHROOM EXHAUST FANS AND DUCTS WITH NEW.

9.

PLUMBING WORK

1.

2.

3.

4.

5.

6. REPAIR BY REPLACEMENT EXISTING BACK FLOW PREVENTER (BFP) AND PRESSURE REDUCING VALVE (PRV) ASSEMBLY, INCLUDING PIPE

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED DOMESTIC HOT WATER STORAGE TANK,DOMESTIC HOT WATER CIRCULATION PUMP, REPAIR BY REPLACEMENT OF EXISTING DETERIORATED BATHROOM PLUMBING FIXTURES AND ASSOCIATED PIPING

WITH NEW.

3.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED AIR HANDLING UNITS AND ASSOCIATED DUCTWORK IN LAUNDRY ROOM WITH NEW.

10.

DOMESTIC HOT WATER RE-CIRCULATION PUMP, EXPANSION TANK, THERMOSTATIC MIXING VALVE AND ASSOCIATED ACCESSORIES WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ALL SEWER, VENT PIPING, FLOOR DRAIN AND CLEANOUT WITH NEW.

SUPPORTS AND HOSE BIBB WITH NEW.

1. REPAIR BY REPLACEMENT OF EXISTING FIRE PROTECTION SYSTEM WITH WET TYPE SPRINKLER SYSTEM AND ASSOCIATED PIPING WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED EXHAUST FANS WITHIN THE MECHANICAL ROOM, LAUNDRY ROOM, TOILET

JANITOR ROOM AND ASSOCIATED DUCT WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED HOT/CHILLED WATER CIRCULATION PUMPS, EXPANSION TANKS, AIR SEPARATORS, TO DRYER, MOTORIZED O.A. DAMPER AND INTAKE LOUVERS WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ELECTRIC WATER COOLERS, SINKS AND VALVE BOXS WITHIN THE LAUNDRY ROOM WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ALL DOMESTIC HOT AND COLD WATER PIPING AND WATER HAMMER ARRESTERS WITH NEW.

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ALL DRAIN AND HOT/CHILLED WATER PIPING THROUGHOUT THE BUILDING WITH NEW.

PIPING WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ELECTRIC CABINET UNIT HEATERS, THERMOSTATS AND UNIT HEATER

WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED FAN COIL UNITS, OUTSIDE AIR INTAKE BOXES, CONTROLS AND ASSOCIATED

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED FIN-TUBE RADIATORS, SPLIT AIR CONDITING UNIT AND ASSOCIATED PIPING WITH NEW.

REPAIR BY REPLACEMENT OF EXISTING DETERIORATED UNIT HEATER, RANGE HOOD AND 100MM DRYER VENT CONNECT

3-WAY MIXING VALVE, CARBON MONOXIDE DETECTOR, DETECTION CONTROLLER, ALARM GONG, CHEMICAL FEEDERS AND ASSOCIATED PIPING WITH NEW.

M-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL EQUIPMENT SCHEDULE - 1

M E C H A N I C A L E Q U I P M E N T S C H E D U L E - 1

AIR

CAPACITY

(CFM)Q'TY SERVICEITEM NO

TOTAL

(BTU/HR)

FCU

COOLING

EAT(°F)

GPM

TYPE

VERTICAL CABINET

FLOOR MTD. TYPE

CHILLED / HOT WATER COIL

ROW

SENSIBLE

(BTU/HR) DB WB

EWT

(°F)

MAX

WPD

(INCH)

HEAT CAP

(BTU/HR)

EAT

(°F)

EWT

(°F)

HEATING

SUPPLY FAN OUTSIDE AIR

HP VOLT/PH/HZ CFM LOUVER SIZE

9,500

44 69 1402.82.1 16,100 115/1/600.08 12"X2"

FCU

800 3 26,600

44 69 1405.9 4,4000 0.17 115/1/60

FCU

3 600 3 18,600 13,700 80

44 69 1404.1 2.7 29,700 115/1/60

REMARKS

REQUIREMENTS.

MOTORIZED O.A INTAKE DAMPER.

7,000

1,8700

FCU

LAUNDRY ROOM & DAY ROOMS VERTICAL CABINET

FLOOR MTD. TYPE

VERTICAL CABINET

FLOOR MTD. TYPE

VERTICAL CABINET

FLOOR MTD. TYPE

300 3 9,500 80 67 44 69 1402.1 2.8 16,100 115/1/607,000

12"X2"30

12"X2"30

12"X2"30

0.08

0.08

3.6

1 EACH UNIT SHALL INCLUDE MANUFACTURER VALVE

3 UNIT SHALL VE PROVIDEO WITH OA WALLBOX WITH

CHARGE PRESSURE=12 PSI

DOMESTIC HOT WATER SYSTEM1 DIAPHRAGM TYPE 350 DIA x 775 HIGHT30 30

1,550 1/10

45WATTS

CEILING MOUNTED,

IN-LINE DUCT MOUNTED TYPE,

(PSI)

MAX. WORKING

PRESSURE

MAX. WORKING

CEMENT LINEDHORIZONTAL TYPE

1 2 3

W/BACKDRAFT DAMPER BIRD SCREENW/DISCONNECT SWITCH

REMARKS

FAN MOTOR

115/1/60

VOLT/PH/HZ

AIR CAP ESP

62.323.6

62.31132.4

RPM

(LPS) (Pa)

1/4

HP

ALL BRONZE CONSTRUCTION

ALL BRONZE CONSTRUCTION

REMARKS

CEILING GRILLE

115/1/60198.2 74.7

(PSI)

PRESSURE

REMARKS

RPM

1,750

MOTOR

VOLT/PH/HZ

200/3/60

HP

HEAD

(KPa)

5185.4

CAPACITY

(LPS)

5.92

1,750

1,750

115/1/60

1-1/2134.5

TYPE

TYPESERVICE

BASE MOUNTED END SUCTION

CENTRIFUGAL TYPE

SERVICE

CENTRIFUGAL TYPE

PIPE MOUNTED IN-LINE

PIPE MOUNTED IN-LINE

CENTRIFUGAL TYPE

BELT DRIVEN, CENTRIFUGAL FAN

Q'TY

P

P

ITEM NO

P

EF

EF

EF

Q'TYITEM NO

EXHAUST AIR FAN FOR MECH ROOM

HOT WATER CIRC. PUMP

CIRC. PUMP

DOMESTIC HOT WATER

FANS

PUMPS

RECIRC. PUMP

DOMESTIC HOT WATER

REMARKS

(LITS)

TANK SIZE

ACCEPTANCE VOLUME TANK SIZE

TYPE

BLADDER TYPE

TANK

SERVICE

TYPE

CAPACITY

ET

ET

ITEM NO

Q'TY

DT

ITEM NO

Q'TY

EXPANSION TANK

HOT WATER SYSTEM

DOMESTIC HOT

WATER SYSTEM

SERVICE

DOMESTIC HOT WATER STORAGE TANK

(MM x MM)

500DIA x 1,525 HIGHT200/3/60

EF

EXHAUST AIR FAN FOR LAUNDRY ROOM

IN-LINE DUCT MOUNTED TYPE,

DIRECT DRIVEN, CENTRIFUGAL FAN

115/1/60

5 PREFABRICATED ROOF CURB.

51,550

ROOF MOUNTED TYPE,

1/15

DIRECT DRIVEN, CENTRIFUGAL FAN

321115/1/60188.7 124.57 EXHAUST AIR FAN FOR BATH ROOM

EF

1,550

IN-LINE DUCT MOUNTED TYPE,

1/12

DIRECT DRIVEN, CENTRIFUGAL FAN

321115/1/60141.5 74.71 EXHAUST AIR FAN FOR TOILET

1,750200/3/6018810.76

BASE MOUNTED END SUCTION

CENTRIFUGAL TYPE

P

CHILLED WATER CIRC. PUMP

CHARGE PRESSURE=12 PSI125140BLADDER TYPE1

ET

CHILLED WATER SYSTEM 500DIA x 1,050 HIGHTONLY 1ST FL COMM. ROOM

(ACU-1)1

2.2 124.1

UNIT SHALL BE SIMILAR TO HARTELL MODEL

MODEL KL201UL OR APPROVED EQUAL.

1.7 FLA 115/1/60 -

LIFT PUMP

CONDENSATE DRAIN

WPD

MAX.

(kPa)

CHILLED / HOT WATER COIL

SERVICE

AIR HANDLING UNIT

Q'TYITEM NO

VOLT/PH/HZ

MOTOR

TYPE

SUPPLY FAN

ESP

LPS

(Pa)

RPM

(MAX.) HP

SENSIBLE

(Kw)

TOTAL

(Kw)

ENT.WATER

COOLING

LPS

MAX.

(kPa)

APD

REMARKS

FACE VEL

EAT.

DB DB

LAT.

WB

MAX.

F/MIN

HEATING

ENT.WATER

TOTAL

(Kw)

EAT

LAT

SETTING

O.A

LANUDRY RM OUTSIDE

198.2

CONCEALED HORIZONTAL

CEILING MOUNTED 249 - 1/2 2.666.72 7.2 0.19

30.5

26.1

15.3

14.4 82.18.50

-15.5

100%AIR MAKE - UP

AHU

TEMP( )

115/1/60

FAN COIL UNIT

1.8 55

1.70

1/3

DIRECT DRIVEN, EXHAUST FAN

EH

ITEM NO Q'TY

W/INTEGRAL THERMOSTAT SIMILAR TO QMARK MODEL CU935 OR APPROVED EQUALFLOOR MOUNTED

TYPE

STAIR-1

208/1/602.0

ELECTRIC CABINET UNIT HEATER

SERVICE TYPE VOLT/PH/HZCAPACITY

HEATING

(KW)

REMARKS

(1ST & 3RD)

EH

2 W/INTEGRAL THERMOSTAT SIMILAR TO QMARK MODEL CU935 OR APPROVED EQUALFLOOR MOUNTED

TYPE

STAIR-2

208/1/602.0

(1ST & 3RD)

47 EXHAUST AIR FAN FOR BATH ROOM & JAN

4 CENTURY ACE MODEL #CAF-300 OR APPROVED EQUAL

5 CENTURY ACE MODEL #CAF-800 OR APPROVED EQUAL

6 CENTURY ACE MODEL #CAF-600 OR APPROVED EQUAL

PACKAGE AS INDICATED ON DETAIL DWG

7 FAN MOTOR UL LISTED : FILE NO E235242

2 COIL CAPACITY SHALL BE BASED ON THE COOLING

NOTES

4321 7

321 7

321 7

4321 7

TEMP( ) C

( C)

WB ( C)

( C)

( C) C

C

C

2,000

(GAL) (INCH DIA x INCH LONG)

60" x 165"

ACU

MULTI PURPOSE RM & ARMS RM,

BED ROOMS, OFFICES, STORAGES,

OFFICE, NBC RM & STORAGE

VEST & C.Q

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

M-4

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

MECHANICAL EQUIPMENT SCHEDULE - 2

M E C H A N I C A L E Q U I P M E N T S C H E D U L E - 2

PIPE SIZE(DIA)

8080PIPE MOUNTED

REMARKS

WITH STRAINER

AIR SEPARATOR

INLET

TYPEQ'TY

AS

ITEM NO SERVICE

HOT WATER SYSTEM

OUTLET

PIPE SIZE(DIA)

8080PIPE MOUNTED

INLETTYPEQ'TY

AS

ITEM NO SERVICE

WATER SYSTEM

OUTLET

CHILLED

VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT REQUIRMENTS.

1. QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR

GENERAL NOTE

REMARKS

4&2 3

HOOD SIZE

(INCH)POWER VOLT/PH/HZ

12.5AMPS

SERVICE TYPE

(CFM)

CAPACITY

FAN FAN MOTOR

ITEM NO Q'TY

RH

RANGE HOOD

INCLUDE4 FE3 BUILT-IN CONTROL SWITCH21 WASHABLE FILTER LIGHTING(75W)

RANGE HOOD 115/1/60 30"x18"

R E M A R KD E S C R I P T I O N

ITEM NO QTY.

EWC

ELECTRIC WATER COOLER

MOTOR : 1/5 HP, 115 V, 1 PH, 60 HZ.

FLOOR MOUNTED TYPE, MECHANICALLY

CAPACITY : 8.0 GPH, 80 DEG.F. TO 50 DEG.F.

AIR COOLED WITH AIR COOLED CONDENSER

& COMPRESSOR SHALL CONFORM TO ARI

STANDARD 1010.

LOUNGE ROOM

NOTE :

(SEER)

9.7

EFFICIENCY

MIN.

54321

4 SHALL BE PROVIDED WITH LOW AMBIENT KIT.WALL MOUNTED DUCT FREE SPLIT COOLING SYSTEM

WITH REMOTE ELECTRONIC CONTROLLER.

3 ALL AC UNITS REFRIGERANT PIPING SHALL BE INSTALLED

PER MANUFACTURER RECOMMENDATIONS.

2CAPACITY SHALL BE BASED ON 35 DEG C1

AIR COOLED TYPE

DUCT LESS WALL MOUNTEDCOMM ROOM1

(0.75 TON)

2,637

102.8 1115/ 1/ 600.41 0.76 FLA

46.5 LRA

7.6 RLA

115/ 1/ 601

ACU

T Y P EITEM NO SERVICE

COMPRESSOR

INDOOR EVAPORATOR UNIT

LPS

TOTAL HEAT

(WATTS) QTY

VOLT/PH/HZ

(FLA)

POWER

OUTDOOR UNIT

QTYPOWER POWER VOLT/PH/HZ

CONDENSER FAN REMARKSQTY.

DRAIN LIFT PUMP SEE SCHEDULE.

UNITS SHALL BE PROVIDED WITH CONDENSATE

SPLIT AIR CONDITIONING UNIT

MECH RM (123)

HORIZONTAL

REMARKS

HP

1/20

VOLT/PH/HZ

115/1/60

RPMLPS

EAT

1,550278.910

(DEG C)

EWT

(KW)

HEATING

CAPACITY LPS

82.16.8 0.07

(DEG C)

TYPESERVICE

DISCHARGE TYPE

Q'TYITEM NO

UNIT HEATER

FAN CAPACITY

UH

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

RATE(GPM)

SERVICE

FINNED TUBE RADIATOR

Q'TYITEM NO

HEATING CAPACITY

(BTU/HR)

EWT HW FLOW

R E M A R K S

(INCH)

LENGTH

ELEMENT

EAT

ROW

1 1/4"DIA STEEL TUBE,

4 1/4" x 4 1/4" x 40FINS/LF 4 2 2'-6"65160

FTR

2,038

LAUNDRY

0.2122,217,317,417

M-5

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

SCALE : 1 / 100-

M5

1ST FL HVAC PLAN

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D D

D D

D D D D DD

C /H

W S

C /H

W R

T

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

D

AND SPILL ON GRADE

W/SPLASH BLOCK (TYP)

FCU

SEE

SEE

FCU

FCU 1

FCU

FCU

FCU

FCU

FCU

EF

150x100

(TYP)

EA LOUVER

250x250

250x100

200x100

EF

FCU

FCU

FCU

STORAGE

VEST

ADMIN OFFICE

R.O

106B

T.O

106A

WAIT AREA

STORAGE

106C

STAIR-2

119B

CO

XO

COMM

MALE

114A FEMALE

114B

JAN

MULTI-PURPOSE RM

116STORAGE

MECH ROOM

C.O

VEST

STAIR-1

119A

LAUNDRY

JAN

CORRIDOR

COMM. RM

105A

SEE DETAIL

100 100

300x50 O.A INTAKE

LOUVER W/ WALL BOX

300x50 O.A INTAKE

EA LOUVER

E-1:200x150

56LPS

U.C

U.C

ACU

(INDOOR UNIT)

(OUTDOOR UNIT)

SEE

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

SEE

250x50 O.A INTAKE

LOUVER W/ WALL BOX

FCU

RA : 750 x 200

M26

REPLACE 600x200

REPLACE 150x100

M10

M9

M10

M10

450x200

OFFICE

ACU

C /H

W S

C /H

W R

C /H

W S

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

ERV

ERV

C /H

W S

C /H

W R

C /H

W S

C /H

W R

C /H

W S

C /H

W R

REMOVE EXISTING AHU AND

ASSOCIATED DUCTWORK(TYP)

D

ASSOCIATED DUCTWORK(TYP)

REMOVE EXISTING AHU AND

102101

OFFICE

T

T T TT

T

TTT

T T T

T

T

TT

EH

EH

SS

SS

LS

POC

BLOCK UP

BLOCK UP

H W

S H

W R

C H

R

C H

S

SCHEDULE AND NOTES

1ST FL HVAC PLAN, AIR DEVICE

C /H

W S

C /H

W R

D

ARMS ROOM

NBC ROOM

ARMS RM

STORAGE

L/S

D

D

D

D

W

W

W

W

LAUNDRY

OFFICE

WATER CHILLER

TO BE REMAINED

1.

NOTES:

CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING SYSTEM

IN MECH. ROOM.

OF DUCT, HWS AND HWR PIPING IN FIELD(TYP)

W

W

D

D

W

D

DRAIN DROP

LOUVER W/ WALL BOX(TYP)

FCU

198.2LPS

E-2:400x400

EXHAUST AIR LOUVER

REPLACE 600x200 450x200

EF 4

198.2LPS

E-2:400x400

EXHAUST AIR LOUVER

REPLACE 600x200 450x200

EF 4

300 DIA WALL VENT

CONNECTTO VENT(TYP)

100 DIA DRYER VENT

DRYER VENT (TYP)

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

FTR

M-6

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

SCALE : 1 / 100-

W

W

D

D

W/D

W/D

M6

2ND FL HVAC PLAN

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

T

D

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

DD

C /H

W R

C /H

W S

DD

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

C /H

W R

C /H

W R

C /H

W S

C /H

W R

C /H

W S

D

C /H

W R

D

C /H

W S

FCU

SEE

FCU

FCU

FCU

FCU

SEE

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

SEE

STAIR-1

218A

DAY RM

219CORRIDOR

BED ROOM

201A

BED ROOM

201B

BED ROOM

202A

BED ROOM

202B

BED ROOM

203A

BED ROOM

203B

BED ROOM

204A

BED ROOM

204B

BED ROOM

205A

BED ROOM

205B

BED ROOM

206A

BED ROOM

206B

BED ROOM

207A

BED ROOM

207B

BED ROOM

208A

BED ROOM

208B

STAIR-2

218B

LAUNDRY

217 BED ROOM

214A

BED ROOM

214B

BED ROOM

213A

BED ROOM

213B

BED ROOM

212A

BED ROOM

212B

BED ROOM

211A

BED ROOM

211B

BED ROOM

210A

BED ROOM

210B

BED ROOM

209A

BED ROOM

209B

JAN

HEATING & COOLING

COMBINATION TYPE

THERMOSTAT(TYP)

FCU

U.C

T T T T T T T T T T T T T T T T

T T T T T T T T T T T T

198.2LPS

E-2:400x400

EF

450x200

M10

M10

M10

M10

M10

450x200 REPLACE 600x200

EXHAUST AIR LOUVER

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

DD

C /H

W R

C /H

W S

D

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

FCU

ERV

SS

LS

C /H

W R

C /H

W S

2ND FL HVAC PLAN AND NOTES

1.

NOTES:

CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING SYSTEM

IN MECH. ROOM.

OF DUCT, HWS AND HWR PIPING IN FIELD(TYP)

300x50 O.A INTAKE

LOUVER W/ WALL BOX(TYP)

WALL CAP

RH

300x50 O.A INTAKE

LOUVER W/ WALL BOX(TYP)

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

M-7

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

SCALE : 1 / 100-

M7

3RD FL HVAC PLAN

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

T

T

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W R

C /H

W R

C /H

W S

D

C /H

W S

C /H

W R

C /H

W R

C /H

W S

D

C /H

W R

D

C /H

W S

FCU

SEE

FCU

FCU

FCU

FCU

SEE

CH

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

SEE

STAIR-1

318A

319CORRIDOR

BED ROOM

301A

BED ROOM

301B

BED ROOM

302A

BED ROOM

302B

BED ROOM

303A

BED ROOM

303B

BED ROOM

304A

BED ROOM

304B

BED ROOM

305A

BED ROOM

305B

BED ROOM

306A

BED ROOM

306B

BED ROOM

307A

BED ROOM

307B

BED ROOM

308A

BED ROOM

308B

BED ROOM

314A

BED ROOM

314B

BED ROOM

313A

BED ROOM

313B

BED ROOM

312A

BED ROOM

312B

BED ROOM

311A

BED ROOM

311B

BED ROOM

310A

BED ROOM

310B

BED ROOM

309A

BED ROOM

309B

STAIR-2

LAUNDRY

JAN

HEATING & COOLING

COMBINATION TYPE

THERMOSTAT(TYP)

FCU

U.C

SEE

T T T T T T T T T T T T T T T T

T T T T T T T T T T T TDAY RM

W

W

D

D

W/D

W/D

SEE

198.2LPS

E-2:400x400

EF

450x200

M10

REPLACE 600x200

EXHAUST AIR LOUVER

450x200

M10 -

M10

M10

M10

EH

EH

SS

LS

3RD FL HVAC PLAN AND NOTES

1.

NOTES:

CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING SYSTEM

IN MECH. ROOM.

OF DUCT, HWS AND HWR PIPING IN FIELD(TYP)

RH

WALL CAP

300x50 O.A INTAKE

LOUVER W/ WALL BOX(TYP)

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

M-8

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

SCALE : 1 / 100-

W

W

D

D

W/D

W/D

M8

4TH FL HVAC PLAN

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C/HWS

C/HWR

D

C/HWS

C/HWR

C/HWS

C/HWR

C/HWS

C/HWR

C /H

W S

C /H

W R

C/HWS

C/HWR

C/HWS

C/HWR

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

C /H

W R

D

T

E A

E A

E A

E A

E A

E A

E A

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

C /H

W R

C /H

W S

FCU SEE

FCU

FCU

SEE

SEE

FCU

EF

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

PIPE GUIDE (TYP)

JOINT (TYP)

BELLOWS TYPE EXPANSLON

PIPE ANCHOR (TYP)

EXHAUST AIR FAN

F.D

F.D

ON ROOF

STAIR-1

418A

CORRIDOR

BED ROOM

401A

BED ROOM

401B

BED ROOM

402A

BED ROOM

402B

BED ROOM

403A

BED ROOM

403B

BED ROOM

404A

BED ROOM

404B

BED ROOM

405A

BED ROOM

405B

BED ROOM

406A

BED ROOM

406B

BED ROOM

407A

BED ROOM

407B

BED ROOM

408A

BED ROOM

408B

BED ROOM

414A

BED ROOM

414B

BED ROOM

413A

BED ROOM

413B

BED ROOM

412A

BED ROOM

412B

BED ROOM

411A

BED ROOM

411B

BED ROOM

410A

BED ROOM

410B

BED ROOM

409A

BED ROOM

409B STAIR-2

418B

LAUNDRY

JAN

250x150

250x250

250x150

250x250

250x150

250x250

250x150

250x250

250x150

250x250

250x150

250x250

250x150

HEATING & COOLING

COMBINATION TYPE

THERMOSTAT(TYP)

(TYP)

EFEXHAUST AIR FAN

ON ROOF

SEE

SEE

U.C

EF

EF

EF

EF

EF

BALANCING VALVE(TYP)

CIRCUIT SETTER

(TYP)

F.D F.D F.D F.D F.D F.D F.D

F.D F.D F.D F.D F.D

T T T T T T T T T T T T T T T T

T T T T T T T T T T T T

DAY RM

198.2LPS

E-2:400x400

EF

450x200

M10

M10

M10

M10

M10

C /H

W R

C /H

W S

SS

LS

4TH FL HVAC PLAN AND NOTES

1.

NOTES:

CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING SYSTEM

IN MECH. ROOM.

OF DUCT, HWS AND HWR PIPING IN FIELD(TYP)

RH

WALL CAP

450x200 REPLACE 600x200

EXHAUST AIR LOUVER

300x50 O.A INTAKE

LOUVER W/ WALL BOX(TYP)

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

M-9

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

150x100

CONNECT TO EXHAUST FAN

2ND FL CEILING

EF

3RD FL CEILING

250x150

F.D

EF

150x100

EF

150x100

F.D

F.D

250x150

F.D

4TH FL CEILING

SCALE : 1 / 50

2 EXHAUST DUCT ISOMETRIC DIAGRAM (TYPICAL)

NOT TO SCALE

M9

M9

MECH ROOM HVAC PARTIAL PLAN

AND NOTES

EXHAUST DUCT ISOMETRIC DIAGRAM(TYPICAL)

MECH ROOM HVAC PARTIAL PLAN

CARBON MONOXIDE

DETECTORS

CARBON MONOXIDE DETECTION

CONTROLLER

CARBON MONOXIDE

ALARM GONG

HT

M

HWR

HWS

C /H

W S

C /H

W R

C /H

W R

C/HWS

C/HWR

C /H

W R

D D D

VTOT OT

AS

EF

UH

HEATING THERMOSTAT

DT

D.H.W. STORAGE TANK

P

P

1 1

ET

ET

SEE

ET

700x450 EXHAUST

AIR LOUVER

FCU

750x300

AS

BLOCK UP OA INTAKE LOUVER

1,100x700 EXHAUST

AIR GRILLE

100100

SEE

1,000x600 OA INTAKE LOUVER

250x50 O.A INTAKE WALL BOX

MODULATING 3-WAY

VENTINATION THERMOSTAT

FOR EF-2

CONTROL VALVE

OUTDOOR AIR THERMOSTAT

OUTDOOR AIR THERMOSTAT

(FOR HEATING SYSTEM)

(FOR COOLING SYSTEM) MOTORIZED O.A.

DAMPER

M5

C H

S

C H

R

M

MODULATING 3-WAY

CONTROL VALVE

TO BE REMAINED

POC

HEATING BOILER & FUEL OIL PIPING

WATER CHILLER

TO BE REMAINED

POC

1.

NOTES:

CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING SYSTEM

IN MECH. ROOM.

CHEMICAL FEEDER

DOMESTIC HOT WATER HEATER

& FUEL OIL PIPING TO BE REMAINED

OF DUCT, HWS AND HWR PIPING IN FIELD(TYP)

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

- M5

M-10

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

REPAIR AND MAINTENANCE WORK

PROVIDE DRYER EXHAUST AIR DUCTWORK5

100MM DRYER CONNECT TO DRYER.6

M10 SCALE : 1/50 -

M10 SCALE : 1/50

GROUND TYP MODULE HVAC PARTIAL PLAN

(2ND THRU 4TH FLOOR)

M10 SCALE : 1/50

LAUNDRY ROOM HVAC PARTIAL PLAN(TYPICAL)

M10 NOT TO SCALE

ISOMETRIC DIAGRAM

SPECIFIC NOTES

DIAGRAM

(1ST THRU 4TH FLOOR) AND ISOMETRIC

TYP MODULE HVAC PARTIAL PLAN

LAUNDRY RM HVAC PARTIAL PLAN(TYP),

TYP MODULE HVAC PARTIAL PLAN(1ST FLOOR)

THERMOSTAT (TYP)

HEATING & COOLING

COMBINATION TYPE

FCU

1C/HWS&C/HWR

(TYP)

( D )

(C/HWS)

(C/HWR)

( D )

(C/HWS)

(C/HWR)

PIPE ENCLOSURE

SEE ARCH.DWG

(TYP)

FCU

& COND.DRAIN

40 DIA COND, DRAIN DROP

AND CONNECT TO DOWN SPOUT

NOZZLE W/SPLASH BLOCK (TYP)

300x50 O.A INTAKE WALL BOX

T

EF

150x100

F.D

THERMOSTAT (TYP)

HEATING & COOLING

COMBINATION TYPE

FCU

1C/HWS&C/HWR

(TYP)

( D )

(C/HWS)

(C/HWR)

( D )

(C/HWS)

(C/HWR)

PIPE ENCLOSURE

SEE ARCH.DWG

(TYP)

FCU

& COND.DRAIN 300x50 O.A INTAKE WALL BOX

250x150

EXHAUST DUCT RISER

TT

200x200 EXHAUST AIR LOUVER

300 DIA WALL VENT

100 DIA DRYER VENT

CONNECTTO VENT(TYP)

EF 2

150x100

600x200 OA

INTAKE LOUVER

450x200

S-2:400x400

198.2LPS

AHU

C/HWS&C/HWR

(TYP)

20 20

ACCESS DOOR

MODULATING 3-WAY CONTROL VALVE

20 DIA COND, DRAIN

450x200

FOR CONT.

SEE(1ST FL. ONLY)

COND. DRAIN(TYP)

C /H

W S

C /H

W R

T S

W C

H

M

W

W

D

D

DRYER VENT (TYP)

DRYER VENT (TYP)

4T H

FL

OOR

40DIA COND. DRAIN CONNECT TO

DOWN SPOUT NOZZLE AND

SPILL OVER SPLASH BLOCK

D C /H

W S

C /H

W R

D C /H

W S

C /H

W R

AUTO

AI

R

VE

NT

3R D

FL

OOR

2N D

FL

OOR

1S T

FL

OOR

4T H

FL

OOR

3R D

FL

OOR

2N D

FL

OOR

1S T

FL

OOR

C/

HW

S C/

HW

R

SE

E

4T H

FL

H

VAC

PL

AN

PROVIDE FLOOR MOUNTED FAN COIL UNIT AND ASSOCIATED PIPING, INTAKE WALL BOX

PROVIDE CEILING MOUNTED EXHAUST FAN, FIRE DAMPERS AND ASSOCIATED DUCT.

PROVIDE DUCT IN LIN EXHAUST FAN AND ASSOCIATED DUCT.

PROVIDE AHU AND ALL ASSOCIATED DUCT AND PIPING.

& CONTROLS.

CHONG, ST

REPAIR BLDG NO. S-473

CAMP CASEY

58480

W

D

M-11

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

NH

STARTER

O/L'S

C2

OFF

AUTO

HAND

MAGNETIC MOTOR

APPROPRIATE SWITCHOVER VALVES SHALL BE MANUALLY OPEN/CLOSED

DEG°F.)(140

(180 DEG°F.)

O.A. TEMP.

DEG°C.

DEG°C.-6.7

15.6

82.2 DEG°C.

H.W. TEMP.

DEG°F.)

DEG°C.DEG°F.) 60.0

1.1

1.

(20

(60

3.

SET VOILER B-1 "HAND-AUTO" SWITCH TO AUTO POSITION, BOILER

WINTER SEASON

STARTS AND RUNS CONTINOUSLY WHEN O.A. THERMOSTAT DROPS BELOW

SET PUMP P-1 "HAND-OFF-AUTO" SWITCH TO "AUTO" POSITION, PUMP

IT'S SETPOINT OF 15.6 DEG.C.

STARTS WHEN P-1 IS ENERGIZED. BOILER PACKAGE CONTROL SHALL

SUMMER-WINTER SWITCHOVER

ACCORDINGLY AS PER SEASON REQUIREMENTS.

MAINTAIN BOILER HOT WATER SUPPLY TEMPERATURE AT 82.2 DEG. C.

SEQUENCE OF OPERATION

TO

O.A. THERMOSTAT

SEE ELECTRICAL DWGS

BOILER

PACKAGED

CONTROLS

AUTO

HAND

C1

AUXILIARY

CONTACT

SWITCH

BOILER

PACKAGED

CONTROLS

SWITCH

C1

NH

O/L'S

C1

OFF

AUTO

HAND

TO

SEE ELECTRICAL DWGS

OUTDOOR

THERMOSTAT

V

OARCOUTDOOR AIR TEMP.

RESET CONTROLLER

OUTDOOR

TEMP.

SENSOR

SUPPLY WATER

TEMP.

SENSOR

1.2

RESET CONTROLLER SHALL MODULATE 3-WAY CONTROL VALVE AND

MAINTAIN HOT WATER SUPPLY TEMPERATURE IN ACCORDANCE WITH THE

FOLLOWING SCHEDULE:

1.3

2. CHILLED WATER SYSTEM:

2.1

STARTS AND RUNS CONTINOUSLY WHEN O.A. THERMOSTAT RISES ABOVE

SET PUMP P-2 "HAND-OFF-AUTO" SWITCH TO "AUTO" POSITION, PUMP

IT'S SETPOINT OF 21.1 DEG.C.

2.2

CLOSES IT'S CONTACT UPON SENSING FLOW AND P-2 IS ENERGIZED.

CHILLER CONTROL SYSTEM IS ENERGIZED WHEN PIPELINE FLOW SWITCH

CHILLER BUILT-IN CONTROL MAINTAIN CHILLED WATER SUPPLY TEMP.

AT -6.7 DEG.C.

BOILER SYSTEM CONTROL EQUIPMENT SCHEDULE

1. O.A. THERMOSTAT:

SPDT SWTCH WHICH MAKES CIRCUIT ON TEMPERATURE FALL,

RDMOTE BULB ELECTRIC TYPE THERMOSTAT, STANDARD RESPONSE

CONTROL RANGE 0-100 DEG F, 5 FEET COPPER CAPILLARY TUVBING,

DIFF= 1.0 DEG.F. ADJ. AND 8 AMPS AT 120VAC.

2 HW RESET CONTROLLER (OARC):

RESET CONTROL FOR THE BOILER HOT WATER HEATING SYSTEM. RAISES

LOW VOLTAGE, ELECTRONIC OR ELECTRIC TYPE SHALL PROVIDE PROPORTIONAL

HEATING MEDIUM CONTROL POINT AUTOMATICALLY AS OUTDOOR TEMPERATURE

FALLS.ONE THERMISTOR SENSOR FOR HEATING MEDIUM, THE OTHER THERMISTOR

SENSOR OUTDOOR AIR TEMPERATURE WITH REMOTE SETPOINT POTENTIOMETER.

RESET RATIO: 1.0 TO 1.0.

NOTES:

1.WIRING INDICATED IS SCHEMATIC. THE CONTRACTOR SHALL

PROVIDE ALL WIRING REQUIRED TO IMPLEMENT THE SEQUENCE

OF OPERATION.

2.PROVIDE SUITABLE ENCLOSURES OR WEATHERPROOF METAL

COVERS FOR ALL INSTRUMENTS, MOTORS, WIRING, AND TUBING

INSTALLED LUTSIDE THE BUILDING

3.ALL WIRING SHALL BE IN ACCDRDANCE WITH DIVISION

16 SPECIFICATION PROVISIONS.

4.PROVIDE AN AUTOMATIC TEMPERATURE CONTROL PANEL WHERE

INDICATED ON THE DRAWINGS. PANEL SHALL BE ENAMEL

FINISHED 14 GAUGE STEEL, NEMA 12 CONSTRUCTION.

CHILLED/HOT WATER PIPING SYSTEM DIAGRAM

120V, 1ø, 60HZ

120V, 1ø, 60HZ

M11

CHILLED WATER PUMP CONTROL CIRCUIT

NOT TO SCALE

P

M11 NOT TO SCALE

BOILER & CHILLER CONTROL

M11 NOT TO SCALE

HW PUMP CONTROL CIRCUIT 1

P

M11 NOT TO SCALE

PIPING SYSTEM DIAGRAM

CONTROLS AND CHILLED/HOT WATER

MECHANICAL

FS

STARTER

OT

MODULATING 3-WAY

CONTROL VALVE

COLD WATER

PIPING LINE

OUTDOOR AIR

RESET CONTROLLER

RC

M

1 EXPANSION TANK

HOT WATERET

C/HWSSENSOR

C/HWR

AIR SEPARATOR

WC

AS

C H

S

1H W

R

C H

R

CHR

CHS

WATER CHILLER

AIR COOLED

T

SUNSHIELD

SUNSHIELD

SENSOR

OA TEMP.

W/REMOTE BULB

OUTDOOR AIR THERMOSTAT

P

CONTROL PANEL

HOT WATER BOILER

H W

S

PRESSURE REDUCING VALVE

SET AT 0.84KG/CM

BACK FLOW PREVENTER

ASSEMBLY

MAKE UP

POSITION

V - 1

V - 2

VALVE

OPEN

WINTERSUMMER

CLOSED

OPEN CLOSED

TO

V-2 V-2

V-1

V-1

HWS

HWR

CHEMICAL FEEDER

W/REMOVABLE FUNNEL

P

CHILLED WATER

EXPANSION TANK 2

ET

CHILLED WATER

CIRC.PUMP

AS

AIR SEPARATOR

OUTDOOR AIR THERMOSTAT

W/REMOTE BULB

HOT WATERP

1 CIRC.PUMP

FLOW SWITCH

(FACTORY SUPPLIED)

FLEXIBLE

CONNECTOR

SUNSHIELD

MODULATING 3-WAY

CONTROL VALVE

(Cv= 17)

VALVE SCHEDULE

CHS

CHR

CHONG, ST

REPAIR BLDG NO. S-473

M-12

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

AND FCU CONTROL DIAGRAM

OUTSIDE AIR SUPPLY UNIT SINGLE ZONE,

MECHANICAL

FAN COIL UNIT CONTROL DIAGRAM

NOT TO SCALEM13

FACTORY PROVIDED WALL MOUNTED

SPACE THERMOSTAT

SWITCH(OFF-HIGH-MEDIUM-LOW)

UNIT MOUNTED 3-SPEED

MAINTAIN ROOM TEMPERATURE AT 23.9 DEG.C

IN WINTER OPERATION :

PIPE MOUNTED CHANGEOVER SWITCH

SWITCH WALL MOUNTED. WHEN FCU IS OPERATED OPEN MOTORIZED OA INTAKE DAMPER.

IN SUMMER OPERATION :

MAINTAIN ROOM TEMPERATURE AT 20 DEG.C

SPACE COOLING THERMOSTAT SHALL CYCLE FCU FAN "ON"OR"OFF" TO

FAN OPERATION IS CONTROLLED BY OCCUPANT VIA 3-SPEED FAN

THE OPERATING MODE (HEATING OR COOLING) SHALL BE DETERMINED BY

SPACE HEATING THERMOSTAT SHALL CYCLE FCU FAN "ON"OR"OFF" TO

T

FCU:

CH

C

SA

MOTORIZED OA

INTAKE DAMPER

OA

(ONLY FOR FCU-1)

CAPACITOR

W

BK

R

BL

BR

BR

FAN

MOTOR

(COMMOM)

(LOW)

(MEDUIM)

(HIGH)

FCU

UNIT MOUNTED

51 2 6

4 8

1 2

TEMPRERATURE CONTROLLER

(110V)

POWER

LN Centry-Ace

F

COOLING

RUN

HEATING

UP DOWN H-C ON/OFF

CAT-100A

FCU WIRING DIAGRAM

Y : YELLOW

* WIRING COLOR *

R : RED

BK : BLACK W : WHITE

BL : BLUE

BR : BROWN

: FIELD WIRING

3 4

DAMPER

MOTOR

TEMP.SENSOR

3-SPEED SWITCH

SEQUENCE OF OPERATION

MECH RM

CO DETECTOR

RELAY(S)

MODULE BOX

ALARM HORN

FL

TO FACP

CARBON MONOXIDE DETECTION SYSTEM

WHEN ANY CARBON MONOXIDE (CO) DETECTORS DETECTS

OPERATION SEQUENCE

100 PPM OR GREATER, DETECTORS SHALL ENERGIES REQUIRED NUMBER OF

B. RELAY MODULE :

RELAY MODULE SHALL BE KIDDE CO12OX.

EQUIPMENT SHALL BE INSTALLED PER MFG INSTRUCTIONS AND IN

ACCORDANCE WITH NFPA 720.

C.

CARBON MONOXIDE DETECTOR SPECIFICATION

CO DETECTOR KIDDE MODEL # i12010SCO OR APPROVED EQUAL

POWER SOURCE: 120VAC, 60HZ 45MA

SALED LITHIUM BATTERY BACKUP

SMOKE SENSOR: IONIZATION

CO SENSOR: ELECTROCHEMICAL

AUDIO ALARM: 85DB AT 10FT

TEMPERATURE RANGE: 40˚F (4.4˚C) TO 100˚F (37.8˚C)

HUMIDITY RANGE: 10%-95% RELATIVE HUMIDITY, NON-CONDENSING

WIRING: QUICK CONNECT PLUG WITH 6" PIGTAILS

INTERCONNECTS: UP TO 24 DEVICES OF WHICH 18 CAN BE INITIATING

STROBE LIGHT: KIDDE MODEL SL177I,

RELAY MODULES TO ACTIVATE FACP AND ACTIVATE ALARM HORN.

NOT TO SCALEM13

CO DETECTION SYSTEM

AND CO DETECTION SYSTEM

WHEN ANY CARBON MONOXIDE (CO) DETECTORS DETECTS

CHONG, ST

REPAIR BLDG NO. S-473

M-13

MECHANICAL

EF

M

O.A.

MOTORIZED O.A.

DAMPER

FOR MECH/ELEC.RM.

OUTSIDE AIR INTAKE

LOUVER W/BIRDSCREEN

G

MAGNETIC MOTOR STARTER

W/A.O.H. SEL. SW

N

C

O.A.

DAMPER MOTOR

T

1PH 120VAC

OL'S

A

H

OFF

H

VENT THERMOSTAT

CONTROL DIAG. FOR EXH. FAN (EF-2)

DM

THERMOSTAT(T-1)

T-1

T

VENTILATION

SEQUENCE OF OPERATION

WHEN SPACE TEMP. RISES ABOVE 37.7 DEG.C, IN-LINE EXHAUST FAN

SHALL OPERATE AND OPEN O.A. INTAKE DAMPER AND MOTORIZED

BACKDRAFT DAMPER VENTILATION TO MAINTAIN T-1 SETPOINT.

E .A

SET AT 37.7 DEG. C.

OL

OFF

C3

(SEE ELECT.DWGS)

120 VAC

ON

EF-4 CONTROL CIRCUIT (TYP FOR EF-5)

SEQUENCE OF OPERATION

EF-5 SHALL BE OPERATED MANUALLY.

DIAPHRAGM TYPE

60DEG.C TO LAUNDRY

BATHROOMS

T-1COPPER WELL

EXPANSION TANK3

ET

P

P

DOMESTIC H.W.

CIRC. PUMP3

P

(TYP)

MIXING VALVE

THERMOSTATIC

HW SENSOR(TYP)

THERMOMETER(TYP)

COPPER WELL

P

P

DOMESTIC HW

RECIRC. PUMP

SEQUENCE OF OPERATION

ITS SETPOINT. T-1 SHALL BE PROVIDED WITH A COPPER CAPILLARY.

REMOTE BULB THERMOSTAT T-1 SHALL CONTROL PUMP P-2 TO MAINTAIN

BE SIMILAR.

DIFFERENTIAL, AND SUITABLE FOR 8 F.L.A. AT 120 VAC. T-2 & P-3 TO

DOMESTIC HOT WATER SYSTEM CONTROL DIAGRAM

T-1 SHALL HAVE A RANGE OF APPROX. 0 TO 77.8DEG.C ADJUSTABLE

H N

2C

LIGHTING CONTACT

RED

CL

L

N

AUTO

HAND

OFF

EF-1

H

C

SEQUENCE OF OPERATION

WHEN THE LIGHT SWITCH IS SWITCHED OFF

EXHAUST FAN SHALL RUN WHENEVER LIGHTIHG SWITCH IS SWITCHED ON

EF-1 CONTROL CIRCUIT

120V, 1Ø, 60HZ

SEE ELECTRICAL DWGS

WELL

THERMOSTAT 26.6°C TO 82.1°C RANGE.

T-1 SHALL BE A REMOTE BULB

O/L

120V TRANSFORMER

MOUNT IN DOMESTIC

C1

HAND

(TYP)

FUSE

SEE ELECTRICAL DWGS

HOT WATER RETURN PIPING

120VAC

N

RELAY

SEE ELECT.

H

L4080

1.7°C DIFFERENTIAL, WIRE TO MAKE ON FALL.

GROUND

LIGHT

GREEN PILOT

MOTOR STARTER

HOLDING COIL

G

OFF

AUTO

T-1

P

NOTE :

(BUILT IN CONTROL)

SHALL BE IN ACCORDANCE WITH THE TEMPERING VALVE MANUFACTURER'S

INSTALLATION INSTRUCTIONS REQUIREMENT.

THE TEMPERING VALVE IN CONJUNCTION WITH HOT WATER RECIRCULATION SYSTEM

PUMP CONTROL

DOM H.W. HEATER

SET AT 60.0 DEG.C

T-1 AQUASTAT

T-2 AQUASTAT

SET AT 37.8 DEG.C

1STORAGE TANK

DOMETIC HOT WATER DT

M13 NOT TO SCALE

VENT SYS CONTROL DIAGRAM

M13 NOT TO SCALE

M13 NOT TO SCALE

M13 NOT TO SCALE

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECH RM

CO DETECTOR

RELAY(S)

MODULE BOX

ALARM HORN

FL

CARBON MONOXIDE DETECTION SYSTEM

WHEN ANY CARBON MONOXIDE (CO) DETECTORS DETECTS

OPERATION SEQUENCE

100 PPM OR GREATER, DETECTORS SHALL ENERGIES REQUIRED NUMBER OF

CO DETECTION SYSTEM FOR OIL BURNING EQUIPMENT

TO FACP

B. RELAY MODULE :

RELAY MODULE SHALL BE KIDDE CO12OX.

EQUIPMENT SHALL BE INSTALLED PER MFG INSTRUCTIONS AND IN

ACCORDANCE WITH NFPA 720.

C.

CARBON MONOXIDE DETECTOR SPECIFICATION

CO DETECTOR KIDDE MODEL # i12010SCO OR APPROVED EQUAL

POWER SOURCE: 120VAC, 60HZ 45MA

SALED LITHIUM BATTERY BACKUP

SMOKE SENSOR: IONIZATION

CO SENSOR: ELECTROCHEMICAL

AUDIO ALARM: 85DB AT 10FT

TEMPERATURE RANGE: 40˚F (4.4˚C) TO 100˚F (37.8˚C)

HUMIDITY RANGE: 10%-95% RELATIVE HUMIDITY, NON-CONDENSING

WIRING: QUICK CONNECT PLUG WITH 6" PIGTAILS

INTERCONNECTS: UP TO 24 DEVICES OF WHICH 18 CAN BE INITIATING

STROBE LIGHT: KIDDE MODEL SL177I,

NOT TO SCALE- M13

RELAY MODULES TO ACTIVATE FACP AND ACTIVATE ALARM HORN.

(TYP FOR EF-5) AND CO DETECTION SYSTEM

EF-4 AND EF-1 CONTROL CIRCUIT

WATER SYSTEM CONTROL DIAGRAM,

VENT SYS CONTROL DIA, DOMESTIC HOT

43.3DEG.C TO

CHONG, ST

REPAIR BLDG NO. S-473

M-14

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

REPAIR AND MAINTENANCE WORK

SIZE AND DIRECTION SMALL BE VERIFIED IN FIELD.

M14 SCALE : 1/100

1ST FL PLUMBING PIPING PLAN

SCALE : 1/100

2ND FL PLUMBING PIPING PLAN

W

W

D

D

W/D

W/D

M14

SPECIFIC NOTES AND NOTES

1ST & 2ND FL PLUMBING PIPING PLAN,

SEE (TYP)

SEE (TYP)SEE

SEE (TYP)

SEE (TYP)

218A

219CORRIDOR

BED ROOM

201A

BED ROOM

201B

BED ROOM

202A

BED ROOM

202B

BED ROOM

203A

BED ROOM

203B

BED ROOM

204A

BED ROOM

204B

BED ROOM

205A

BED ROOM

205B

BED ROOM

206A

BED ROOM

206B

BED ROOM

207A

BED ROOM

207B

BED ROOM

208A

BED ROOM

208B

STAIR-2

218B

LAUNDRY

217 BED ROOM

214A

BED ROOM

214B

BED ROOM

213A

BED ROOM

213B

BED ROOM

212A

BED ROOM

212B

BED ROOM

211A

BED ROOM

211B

BED ROOM

210A

BED ROOM

210B

BED ROOM

209A

BED ROOM

209B

JAN

STAIR-1

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S V S V S

VSVS VS

V S

VS

V S

VS

V S

VS

SV

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

M18 -

M17

M17 -

M17

M17

SPECIFIC NOTES

EWC

SS

LS

SEE SEE

50 50

50 50 3250 50

W

SEE (TYP)

1ST FL. CEILING PIPING1ST FL. CEILING PIPING1ST FL. CEILING PIPING

STORAGE

VEST

104 ADMIN OFFICE

R.O

106B

T.O

106A

WAIT AREA

STORAGE

106C

STAIR-2

119B

CO

XO

COMM

111112

MALE

114A

FEMALE

114B

JAN

MULTI-PURPOSE RM

STORAGE

MECH ROOM

C.Q

VEST

STAIR-1

119A

LAUNDRY

JAN

CORRIDOR

STORAGE

105A

5040 65

100 C.O 100 C.O

(TYP)

100 C.O

(TYP)

1ST FL. CEILING PIPING

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

SV

M18

100 100

S

S

S

M16 -

M19

PIPING BELOW SLAB

PIPING BELOW SLAB

PIPING BELOW SLABPIPING BELOW SLAB

CONNECTION TO EXISTING SEWER LINE

CONNECTION TO EXISTING SEWER LINE

SEWER LINE

CONNECTION TO EXISTING

SEWER LINE

CONNECTION TO EXISTING

EWC

EWC

SV

VS

OFFICE

VS

SV

SS

LS

NOTES:

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE DIRECTION OF

HOT WATER, COLD WATER, SEWER AND VENT PIPING IN SITE(TYP)

2. CONTRACTOR SHALL SUBMIT DRAWING FOR PLUMBING PIPING

(HOT, COLD WATER, SEWER AND VENT PIPING) PRIOR TO HOT, COLD,

SEWER, VENT PIPING INSTALLATION.

OFFICE

ARMS ROOM

NBC ROOM

32 32

3232 3232

32 32

32 32

32 32

32 32

32 32

ARMS RM

STORAGE

OFFICE

W

W

W

W

L/S

D

D

D

D

LAUNDRY

W

W

D

D

W

D

DAY ROOM

S

REPLACE EXISTING DETERIORATED ALL DOMESTIC CW, H.W, PIPING WITH NEW.

REPLACE EXISTING DETERIORATED ALL SEWER AND VENT PIPING WITH NEW.

EXIST SEWER PIPING BELOW SLAB TO REPLACE, EXACT PIPE LOCATION,

WATER HAMMER ARRESTOR

(PDI:"B" TYPE)(TYP OF 2)

(TYP.)

ACCESS DOOR(TYP)

CHONG, ST

REPAIR BLDG NO. S-473

M-15

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M15 SCALE : 1/100

3RD FL PLUMBING PIPING PLAN

M15 SCALE : 1/100

4TH FL PLUMBING PIPING PLAN

W

W

D

D

W/D

W/D

W

W

D

D

W/D

W/D

SPECIFIC NOTES AND NOTES

3RD & 4TH FL PLUMBING PIPING PLAN,

SEE (TYP)

SEE (TYP)SEE

SEE (TYP)

SEE (TYP)

318A

319CORRIDOR

BED ROOM

301A

BED ROOM

301B BED ROOM

302A

BED ROOM

302B

BED ROOM

303A

BED ROOM

303B

BED ROOM

304A

BED ROOM

304B

BED ROOM

305A

BED ROOM

305B

BED ROOM

306A

BED ROOM

306B

BED ROOM

307A

BED ROOM

307B

BED ROOM

308A

BED ROOM

308B

BED ROOM

314A

BED ROOM

314B

BED ROOM

313A

BED ROOM

313B

BED ROOM

312A

BED ROOM

312B

BED ROOM

311A

BED ROOM

311B

BED ROOM

310A

BED ROOM

310B

BED ROOM

309A

BED ROOM

309B

STAIR-2

LAUNDRY

JAN

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S

VS

V S V S V S

VSVS VS

V S

VS

V S

VS

V S

VS

SV

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

S V

SV

SV

M18 -

M17 -

M17

M17 -

M17

SEE (TYP)

SEE (TYP)SEE

1 1 1 1 1 1 1 1

1 1 1 1 1 1

SEE (TYP)

SEE (TYP)

PIPE GUIDE (TYP)

JOINT (TYP)

BELLOWS TYPE EXPANSION

PIPE ANCHOR (TYP)

222222

STAIR-1

418A

419CORRIDOR

BED ROOM

401A

BED ROOM

401B

BED ROOM

402A

BED ROOM

402B

BED ROOM

403A

BED ROOM

403B

BED ROOM

404A

BED ROOM

404B

BED ROOM

405A

BED ROOM

405B

BED ROOM

406A

BED ROOM

406B

BED ROOM

407A

BED ROOM

407B

BED ROOM

408A

BED ROOM

408B

BED ROOM

414A

BED ROOM

414B

BED ROOM

413A

BED ROOM

413B

BED ROOM

412A

BED ROOM

412B

BED ROOM

411A

BED ROOM

411B

BED ROOM

410A

BED ROOM

410B

BED ROOM

409A

BED ROOM

409B

STAIR-2

418B

LAUNDRY

JAN

20 20 20 20

20 80 20 80 20 80

S S S S S S S S

S

S S S S S S

S S

S S

S S S S S

S S S S

V

S

V V V V V V

V

V V V V V V

V

100ø VTR(TYP) 100ø VTR(TYP)

M18 -

M17 -

M17

M17 -

M17

EWC

EWC

SS

SS

LS

LS

NOTES:

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE DIRECTION OF

HOT WATER, COLD WATER, SEWER AND VENT PIPING IN SITE(TYP)

2. CONTRACTOR SHALL SUBMIT DRAWING FOR PLUMBING PIPING

(HOT, COLD WATER, SEWER AND VENT PIPING) PRIOR TO HOT, COLD,

SEWER, VENT PIPING INSTALLATION.

DAY ROOM

DAY ROOM

REPAIR AND MAINTENANCE WORK

SIZE AND DIRECTION SMALL BE VERIFIED IN FIELD.

SPECIFIC NOTES

REPLACE EXISTING DETERIORATED ALL DOMESTIC CW, H.W, PIPING WITH NEW.

REPLACE EXISTING DETERIORATED ALL SEWER AND VENT PIPING WITH NEW.

EXIST SEWER PIPING BELOW SLAB TO REPLACE, EXACT PIPE LOCATION,

CHONG, ST

REPAIR BLDG NO. S-473

M-16

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M16 SCALE : 1/50

AND NOTES

MECH ROOM PLUMBING PARTIAL PLAN

MECH ROOM PLUMBING PARTIAL PLAN

S

SV

VS

S

AS

P

DT

P

P

P

ET

ET

ET

BACK-FLOW PREVENTER

PRESSURE REDUCING VALVE

AS

THERMOSTATIC

MIXING VALVE

325050