Text version

Remove double door and replace with a single door, frame and hardware.

New wall

New door, frame and hardware.

OBI #1 New door, frame and hardware.

New wall.

Remove flooring and replace with new carpeting.

Provide wall to fill the area of the door that was removed

Remove flooring and replace with new carpeting.

Remove flooring and replace with new carpeting.

Provide new lock set for door.

173b

129b

173a

129a

Remove door.

Leave frame.

OBI #2

Floor Plan Remove ceiling tiles and replace with new tiles.

Remove ceiling tiles and replace with new tiles.

OBI #1.

173b

129b

173a

129a

OBI #2

EX S

Notes Rearrange/rewire lighting circuits as needed.

Demo existing lighting and provide 3 new lights each for Rooms 173 and 175.

Room 175: Move existing switch closer to the new single door.

Room 173: Provide blank plate to cover switch next to Door 173a

OBI #1

Add new 3 pole switch next to new door.

OBI #2

Provide new ceilings in Rooms 129, 129a, and 129b.

Room 129: Demo existing light, and provide 2 new lights. Replace 3 pole switch with single pole switch. 2 lights on single pole switch.

Room 129a: Remove existing 3 pole switch, and rewire lights to be controlled by single pole switch in Room 127.

Room 129b: Install single pole switch to control 2 lights and move the existing lights.

NS3

EX S3

EX S3

NS

EX S3

127EX S

EX S3

Lighting Plan

Legend

*Proposed light locations with “N” denotes that subject light is new. All others will be reused.

Proposed Lighting Locations*

Existing Lighting

EX S

EX S3

Existing Single Pole Switch

Existing 3-Pole Switch

NS

NS3

New Single Pole Switch New 3-Pole Switch

N

N

NNN

N N N

N

N

N

N

N

Provide new receptacles (8 total) where shown. New outlets shall be on a new circuit. Provide new circuit breaker if needed.

Circuits will be ran to Panel C. N New receptacle

Legend

Subject rooms

OBI #2

Power Plan

New walls

Replace existing return with 24 x 12

Provide new branch ductwork, VAV box, thermostat and controls for Rooms 173 & 175

Replace existing diffusers with appropriately sized diffusers. 250 CFM each.

Adjust VAV box to eliminate flow to 173 and 175

Thermostat Placement

Utilities Plan

250 CFM

250 CFM