S E
N S
O R
S
740 S PIERCE AVE UNIT 15
LOUISVILLE, CO 80027
+1.303.494.3230 sales@bditest.com
+ Cost effective + Installs in 5 minutes or less + Reusable, lasts for >10 years + Waterproof to 20ft (6 m) + Industrial cable, custom lengths + Standard millivolt output + N.I.S.T traceable calibration
+ Steel + Pre-stress/post-tension concrete + Reinforced concrete + Timber + Fiber Reinforced Polymer (FRP) + Live-Load testing & monitoring + Laboratory testing + Fatigue monitoring + Tension rod forces
STEEL
CONCRETE
THE ST350 STRAIN TRANSDUCER HAS BEEN DESIGNED TO QUICKLY AND ACCURATELY
MEASURE STRAIN ON A VARIETY OF STRUCTURES IN HARSH FIELD ENVIRONMENTS. THIS
350Ω FULL WHEATSTONE BRIDGE STRAIN TRANSDUCER IS VERY ACCURATE, RUGGED, AND
WATERPROOF. PROVIDING ROUGHLY 3.5 TIMES THE OUTPUT OF A TYPICAL FOIL STRAIN GAGE, THESE REUSABLE SENSORS ARE IDEAL FOR MEASURING LIVE-LOAD STRAIN ON STRUCTURES
AND CAN BE INSTALLED WITHIN MINUTES IN ALL WEATHER CONDITIONS.
FEATURES
DIMENSIONS
APPLICATIONS
ST350 | STRAIN TRANSDUCER
©2019 BDI, All Rights Reserved | V3.0-0119
BDITEST.COM
1 Intelliducer connector required with STS Intelliducer data acquisiton nodes.
2 Accuracy defined at the calibrated ±2,000 µε range.
3 Temperature limit based on instrumentation cable operating temperatures, call BDI for wide temperature range cable options.
MODEL ST350
TYPE 350Ω
CIRCUIT Full Wheatstone bridge with 4 active 350Ω strain gages
EXCITATION VOLTAGE +1.0 to +10.0 Vdc
OUTPUT mV level, ratiometric to Excitation Voltage
OFFSET < 1.5 mV at time and temperature of calibration
POWER:
MAX
TYPICAL
INTELLIDUCER1
300 mW 72 mW @ +5.0 Vdc 13 mW @ +5.0 Vdc
STRAIN RANGE ±4,000 µε (Calibrated to ±2,000 µε)
FORCE REQUIRED FOR 1000 µε ~17 lbs (~76N)
TYPICAL SENSITIVITY ~500 µε/mVout/ Vin
ACCURACY2 < ±1%
CALIBRATION Individually calibrated using N.I.S.T. - traceable automated system. Calibration curve & factor provided
THERMISTOR (OPTIONAL) 3 kΩ - NTC
EFFECTIVE GAGE LENGTH 3.0 in (76.2 mm) [Gage Extensions available for R/C Structures]
CABLE
Custom lead cable length made to order:
IC-02-187 [22 AWG 2 shielded pair, drain wire, red PVC jacket] IC-02-250 [22 AWG, 2 shielded pair, drain wire, blue PVC jacket] IC-03-250 [24 AWG, 3 shielded pair, drain wire, black PVC jacket]
HOUSING Machined 6061 Aluminum Alloy
CORROSION PROTECTION Hard Anodized Clear (MIL-A-8625 Type III)
WEATHER PROTECTION Designed to exceed IP67 Optional 100 ft (30 m), waterproofing available
TEMPERATURE RATING3 -58° to +176 °F (-50° to +80 °C)
SIZE 4.38 in x 1.25 in x 0.50 in (111 mm x 32 mm x 12.7 mm)
WEIGHT 0.19 lbs. (85 g)
MOUNTING Through holes for ¼ in (M6) bolts or anchors Reusable mounting tabs (gluing/welding)
Intelliducer Connector: Required for use with STS Intelliducer Nodes, cable is connected and potted for a weatherproof seal.
Integrated Thermistor: Temperature range of -55 °C to +220 °C, ±0.5 °C accuracy.
Reusable Mounting Tabs: ¼-20 or M6, zinc plated steel mounting tab.
Tab Jig: Machined aluminum jig for safely attaching mounting tabs to the strain transducer. Includes either 7/16" or M10 end wrench.
Gage Extension: Machined aluminum 24 in (610 mm) gage length extension with 3.0 in (76 mm) increments
Extension Jig: Aluminum mounting jig for safely attaching gage extensions
Installation Jigs: Welding or concrete drilling jigs
Protective Covers: Insulated aluminum protective covers
Available in: GS07F197CA
SPECIFICATIONS
OPTIONS & ACCESSORIES