Text version

W22W9K00690143

This is a Request for Proposal (RFP) to provide all management, personnel, materials, supplies and equipment necessary to extend permanent electrical pow er to the dow nstream end of the locks, enabling quickly temporary pow er connection to docked barges during high w ater events. This w ork w ill require the installation of a pad mounted transformer, panelboards, 200 A 4-pin and sleeve receptacles, and lighting to serve this area. Additional w ork involves the installation of a concrete encased ductbank for w iring connection f rom existing sectionalizing sw itch located across from the Maintenance building to the harbor area and a concrete pad for the pow er equipment listed above for the Olmsted Lock and Dam, Olmsted IL.

The Estimated Price Range is betw een $250,000 and $500,000, in accordance w ith FAR 36.204.

NAICS Code: 238210 Size Determination: $16,500,000, Electrical Contractors and Other Wiring Installation Contractors.

JOHN C BUTTS 502.315.6172

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

30-Apr-2020

(RFP)

(IFB)

X

CALL:

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________120 calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________FAR 52.211-10

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

X YES NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________1 copies to perform the w ork required are due at the place specif ied in Item 8 by ___________ local time ______________24 Apr 2020 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time of fers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______30 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

U. S. ARMY ENGINEER DISTRICT, LOUISVILLE

600 DR. MARTIN LUTHER KING, JR. PLACE

ROOM 821

LOUISVILLE KY 40202-2239

W912QR

PAGE OF PAGES

1 OF

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

10:00 AM (hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

8. ADDRESS OFFER TO (If Other Than Item 7)

502.315.6195 OR 6193FAX:TEL: 502.315.6172 TEL: FAX:

W912QR20Q0051 63

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

Section 00 10 00 - Solicitation

SPECIAL ISNTRUCTIONS

This is a Request for Proposal (RFP) to provide all management, personnel, materials, supplies and equipment necessary to extend permanent electrical power to the downstream end of the locks, enabling quickly temporary power connection to docked barges during high water events. This work will require the installation of a pad mounted transformer, panelboards, 200 A 4-pin and sleeve receptacles, and lighting to serve this area. Additional work involves the installation of a concrete encased ductbank for wiring connection from existing sectionalizing switch located across from the Maintenance building to the harbor area and a concrete pad for the power equipment listed above for the Olmsted Lock and Dam, Olmsted IL.

LOCATION:

U.S. Army Corps of Engineers Olmsted Lock and Dam 567 New Dam Road Olmsted, IL 62970 Contracting Officer Representative (COR) is: Paul Dierker (618) 256-4733 or paul.s.dierker@usace.army.mil

This procurement is 100% set-aside for Small Business, NAICS 238210 ($16.5M) Electrical Contractors and Other Wiring Installation Contractors.

Note: The contract award will be based on Lowest Price. The offeror must complete the Price Breakout schedule and Reps and Certs page contained herein. One award will be made from this RFP. The contract type is a Firm Fixed Price Purchase Order.

Method of Payment under this contract will be Electronic Funds Transfer (EFT) to a commercial bank account specified by the Contractor.

Quotes are due 24 April 2020, 10:00AM ET. Please submit quotes to john.c.butts@usace.army.mil. Faxed, telephoned, or mailed submittals will not be accepted. Quotes shall be valid for 30 calendar days.

All contractors must be registered in the System for Award Management (www.SAM.gov) prior to award of a contract. All proposed contractors are highly encouraged to review FAR Clause 52.232-33 Payments by Electronic Funds Transfer – System for Award Management, which indicates “All payments by the Government under this contract shall be made by electronic funds transfer (EFT).” Those not currently registered can obtain registration by going to the website http://www.SAM.gov. The process can usually be completed from 24 to 48 hours after submission. Contractors will need to obtain a Unique Entity Identifier (formerly DUNS number) for processing their registration. If you do not already have a Unique Entity Identifier, one can be obtained from http://www.SAM.gov.

Refer to www.SAM.gov for information formerly found in CCR, EPLS, ORCA and FedReg.

Please begin the registration process immediately in order to avoid delay of the contract award should your firm be selected.

ALERT: You must submit a notarized letter appointing the authorized Entity Administrator before your registration will be activated. This requirement now applies to both new and existing entities. Effective 29 April 2018, the notarized letter process is now mandatory on all CURRENT registrants at SAM who have a requirement to update data on their SAM record. The notarized letter is mandatory and is required before the GSA Federal Service Desk (FSD) will activate the entity's registration.

Effective 29 June 2018, vendors creating or updating their registration can have their registration activated prior to the approval of the required notarized letter. However, the signed copy of the notarized letter must be sent to the GSA Federal Service Desk (FSD) within 30 days of activation or the vendor risks no longer being active in SAM.

PLEASE NOTE: SAM is completely free of charge for both registrants and users.

Page numbering in this document may not be accurate.

PRICE BREAKOUT SCHEDULE

Line Item:

Bid Item: Qty Unit Cost Cost

0001 High Water Mooring Electrical Job $ $

TOTAL

Section 00 20 00 - Instructions for Procurement

SCOPE OF WORK

GENERAL –

HIGH WATER MOORING ELECTRICAL

SCOPE OF WORK

6 MARCH 2020

Provide all labor, material and equipment necessary to extend permanent electrical power to the downstream end of the locks, enabling quickly temporary power connection to docked barges during high water events. This work will require the installation of a pad mounted transformer, panelboards, 200 A 4-pin and sleeve receptacles, and lighting to serve this area.

Additional work involves the installation of a concrete encased ductbank for wiring connection from existing sectionalizing switch located across from the Maintenance building to the harbor area and a concrete pad for the power equipment listed above.

Provide all labor, material and equipment (including accessories such as fuses, etc.) necessary for a complete and operable system.

1. SCHEDULE – All shall be completed within 120 calendar days from Notice to Proceed.

2. REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

National Fire Protection Association (NFPA) NFPA 70 (2020) National Electrical Code

Institute of Electrical and Electronics Engineers (IEEE)

IEEE 400.2 (2013) Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)

American Society for Testing and Materials (ASTM)

ASTM C33/C33M (2013) Standard Specification for Concrete Aggregates

US Army Corps of Engineers

EM385-1-1 (2014 or latest version if superseded) Safety and Health Requirements Manual

3. SPECIFICATIONS

A.

The existing sectionalizing switch is designated with a square symbol on the reference site electrical drawings ES101 and labeled PMH-9D. The sectionalizing switch is an S&C pad mounted gear with a total of 4 bollards, 1 bollard at approximately 16 inches from the concrete pad at each corner.

Provide all labor, material and equipment necessary to furnish and install (3) #2 Copper, 5 KV, 133%, EPR insulated, shielded, LDPE jacket and (1) #2 ground conductor from PMH-9D Bay #3 to 300 KVA transformer. Terminations shall be made with 200 A load break elbows at the transformer side and 5 KV outdoor rated stress cones on PMH- 9D. Furnish and install (3) S&C SMU-20 fuses rated 45E Amps.

Test cable in accordance with IEEE 400.2 and manufacturer recommendations and furnish to Contracting Officer Representative.

The conductors will travel in one of the (2) 4” conduits of the underground concrete encased ductbank. The empty conduit shall have pullwire. The path of the ductbank will be as marked on sheet ES101, coordinate with security fence path. Refer to sheet ES502 for medium voltage ductbank detail.

A 2’ x 3’ x 2’handhole shall be placed at midpoint between PMH-9D sectionalizing switch and 300 KVA transformer. Refer to sheet ES101 for handhole location.

Provide all labor, material and equipment necessary to furnish and install a 300 KVA, 4160 V- PRI, 480/277 V-SEC, Delta-Wye, oil filled, pad mounted, dead front, transformer with double bushing inserts, copper wound, liquid level, temperature gauge, pressure relief valve, drain valve for sampling and lightning arrestor load break elbows.

Provide all labor, material and equipment necessary to furnish and install (1) 400 A, 480/277 V equipment panel, (1) 100 A, 120/240 V MLO equipment panel, (1) 10 KVA, 1 phase, 480 V/240-120 V transformer, and (2) 200 A, 480 V, non-fused, heavy duty disconnect switches with (1) 4-pin receptacle and junction box each. Provide applicable ground fault protection per NEC. The 300 KVA transformer shall provide power to the equipment listed previously.

Provide all labor, material and equipment necessary to furnish and install (1) 277 V, 40 K, and full cut-off type LED fixture with aluminum finish. Light fixture shall be mounted 10 feet above ground on a RGS conduit attached to frame. Lighting shall be turned on and off by means of photocell and motion sensor, including a manual override.

Installation shall be in accordance with NFPA 70.

B.

The reinforced concrete pad for the pad mounted transformer and the electrical support frame shall be constructed of a Portland cement with a minimum compressive strength of 4,000 psi according to sheets CS101 and CS501 and reinforcement shall consist of 6x6 – W2.9xW2.9 wire fabric according to CS501.

Coarse aggregate shall conform to ASTM C33/C33M, Class 5S, and a size designation of

¾”. Fine aggregates shall conform to the quality and gradation requirements of ASTM C33/C33M.

A compacted aggregate base layer shall consist of dense graded aggregate and shall be installed to minimum depth of 6” below the concrete pad. See sheets CS501 for further aggregate grading details.

The top of the concrete slab shall be constructed to Elevation 340’ and shall ensure positive drainage to the west. The concrete slab shall have a maximum lateral and longitudinal slope of 1.0%.

The contractor shall provide sufficient detailed information of underground duct bank path and facilitate as-built documentation on the site drawings.

4. SITE VISIT

The Scope of Work only contains basic requirements for reference. It is recommended that each bidding contractor visit the job site and assume responsibility for quantities, materials, critical dimensions and work conditions used to calculate a proposal. To schedule a site visit contact the onsite point of contacts below.

A site visit can be arranged by contacting the on-site POC: William Gilmour Olmsted Lock and Dam 567 New Dam Road Olmsted, IL 62970

(618) 748-6416

5. SPECIAL REQUIREMENTS

A. GOVERNMENT CONTRACTING: All contractors will supply Federal Tax ID, Unique Entity Identifier and be registered in SAM before this contract will be awarded. Instructions for obtaining a Unique Entity Identifier number and registration with SAM are at the end of this document. Contractor shall comply with the provisions of the Buy American Act.

B. DAMAGES: The contractor shall be responsible for all damages to government or private property resulting from negligent operations during the course of this contract. The contractor shall have appropriate insurance to cover liability and damages. The contractor shall be responsible for compensating the government for any damage to government property.

C. COORDINATION: Other contractors are working on site, therefore coordination and cooperation between contractors shall be required.

D. SAFETY: All work will be conducted in a safe manner. A pre-work meeting will be held to discuss safety procedures, and a plan of work. The Work must be performed in compliance with EM385-1-1 Safety and Health Requirements Manual, Corps of Engineers (current edition).

http://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_385-1-1.pdf The contractor shall supply the POC with an Accident Prevention Plan (APP) and an Activity Hazard Analysis (AHA).

E. WAGE RATES: Department of Labor wage rates apply to this work and are included. Wage rates will be determined based upon actual work location. The contractor is required to provide payroll documents for all work performed under this contract.

F. DEBRIS REMOVAL: The contractor will remove all demolition debris and left over construction debris to a site licensed to receive/recycle construction debris and is subject to approval. The contractor is responsible for any waste disposal and any permits and fees associated with disposal. Any waste water employed in cutting, washing, and rinsing of concrete surfaces shall be disposed of in a manner that the waste water does not stain, discolor, or affect exposed surfaces of the structures, or damage the environment of the project area.

G. COMPLIANCE AND CERTIFICATIONS: The contractor is responsible for obtaining any permits and paying any associated fees necessary to install and inspect all work specified herein.

H. WARRANTY: The contractor shall provide a minimum 5 year warranty on all LED Luminaires per the specifications in section 3.A of this Statement of Work and shall provide a 1 year warranty or standard warranty whichever is greater on the entire system installation to the Lockmaster upon completion dated with the final acceptance date.

I. EQUIPMENT SUBMITTALS: The contractor shall provide electronic submittals to the contracting officer or designated representative for all electrical apparatus.

J. WORK PLAN SUBMITTAL: A detailed work plan shall be prepared for approval by the contracting officer or designated representative prior to commencing with the work. Include cable installation plan showing compliance with manufacturer pulling tensions and termination procedures.

A sample of each type of connection shall be prepared in the presence of the contracting officer or designated representative for approval prior to terminating the medium voltage cables.

W912QR20Q0051

6. PAYMENTS:

Payment will be made by Electronic Funds Transfer (EFT), upon acceptance of the completed work and providing final invoice.

Invoice shall be mailed to:

Olmsted Resident Office Attn: William Gilmour 567 New Dam Road Olmsted, IL 62970

7. SECURITY:

A. ACCESS AND GENERAL PROTECTION/SECURITY POLICY AND

PROCEDURES

All contractor and all associated sub-contractors employees shall comply with applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative). The contractor shall also provide all information required for background checks to meet installation/facility access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any installation or facility change, the Government may require changes in contractor security matters or processes.

B. DOD FACILITY OR INSTALLATION ACCESS

Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014-05 / AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative, as NCIC and TSDB are available), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.

C. SUSPICIOUS ACTIVITY REPORTING TRAINING

The contractor and all associated sub-contractors shall receive a brief/training provided by the project manager or designated representative on the local suspicious activity reporting program. This locally developed training will be used to inform employees of the types of behavior to watch for and instruct employees to report suspicious activity to the project manager, security representative or law enforcement entity. This training shall be completed within 30 calendar days of contract award and within 30 calendar days of new employees commencing performance with the results reported to the project manager NLT 5 calendar days after the completion of the training.

D. SENSITIVE OR RESTRICTED AREA ACCESS

All contract employees, including subcontractor employees who are not in possession of the appropriate security clearance or access privileges, will be escorted in areas where they may be exposed to classified and/or sensitive materials and/or sensitive or restricted areas.

E. PRE-SCREEN CANDIDATES USING E-VERIFY PROGRAM

The Contractor must pre-screen Candidates using the E-verify Program (http://www.uscis.gov/e-verify) website to meet the established employment eligibility requirements. The Vendor must ensure that the Candidate has two valid forms of Government issued identification prior to enrollment to ensure the correct information is entered into the E-verify system. An initial list of verified/eligible candidates must be provided to the project manager no later than 3 business days after the initial contract award.

8. Equal Opportunity for Veterans

In addition to complying with the requirements outlined in FAR Part 22.13, FAR Clause 52.222-35, FAR Clause 52.222-37, DFARS 222.13 and Department of Labor Regulations, U.S. Army Corps of Engineers (USACE) contractors and subcontractors at all tiers are encouraged to promote the training and employment of U.S. veterans while performing under a USACE contract. While no set-aside, evaluation preference, or incentive applies to the solicitation or performance under the resultant contract, USACE contractors are encouraged to seek out highly qualified veterans to perform services under this contract.

The following resources are available to assist USACE contractors in their outreach efforts:

- U.S. Department of Labor Veterans’ Employment and Training Service (VETS):

https://www.dol.gov/vets/

- Federal Veteran Employment Information: https://www.fedshirevets.gov/

- Veterans Opportunity to Work (VOW) Program: https://www.benefits.va.gov/vow/

- U.S. Army Warrior Transition Command Employment Index:

https://wct.army.mil/modules/employers/index.html

- Hiring Our Heroes: https://www.uschamberfoundation.org/hiring-our-heroes USACE has the right to remove operators if not complying with regulations

VICINITY MAP

M

Louisville District of Engineers US Army Corps

11-MAR-2020

K:\COMMON\Olmsted\2020 Reviews\High Water Mooring Electrical\00 - Drawings\Bentley\sheets\_112574_X100.dgn

DATE:

FILE:

AND APPROVAL OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET.

SIGNATURES AFFIXED BELOW INDICATE OFFICAL RECOMMENDATION

Quality Control

Approval Recommended: *

PE/A

Approved: *

THE SCOPE OF THIER EMPLOYMENT. SIGNATURES ARE REQUIRED BY ER 1110-1-8152.

DESIGNATIONS APPEAR ON THESE DOCUMENTS ARE OPERATING WITHIN

LOUISVILLE DISTRICT. INDIVIDUALS WHOSE SIGNATURES AND REGISTRATION

* THIS PROJECT WAS DESIGNED BY THE U.S. ARMY CORPS OF ENGINEERS,

Reviewed by:*

DATE

DATE

DATEENGINEERING DIVISION, CHIEF

JOHN R. BOCK

TINA BEAVIN

JIM WALTERS

W229K00690143

CERTIFIED FINAL

OLMSTED HIGH WATER MOORING ELECTRICAL

OLMSTED, ILLINOIS

OLMSTED LOCKS

OHIO RIVER

INDEX

SHEET REFERENCE NUMBERFILE NAME SHEET NUMBER SHEET NAME

ELECTRICAL SITE DETAILS

ELECTRICAL SITE DETAILS

ELECTRICAL SITE DETAILS

ELECTRICAL SITE PLAN

CONCRETE TRANSFORMER PAD

SITE PLAN

COVER SHEET

ES503

ES502

ES501

ES101

CS501

CS101

X100

_112574_ES503.DGN

_112574_ES502.DGN

_112574_ES501.DGN

_112574_ES101.DGN

_112574_CS501.DGN

_112574_CS101.DGN

_112574_X100.DGN

3 314

331 332

14'

SEE DETAIL SHEET CS501

TOP OF PAD - EL 340

8" REINFORCED CONCRETE PAD

EXISTING BURIED ANCHOR POINTS

OLMSTED BM#6

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

A

B

C

D

E

F

G

1 98765432

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

D

R

M A

R T

IN

L

U T

H E

R K

IN

G J

R P

L A

C E

L O

U

IS

V

IL

L E

K E

N T

U C

K Y

O L

M S

T E

D

IL

H

IG

H W

A T

E R M

O O

R

IN

G E

L E

C T

R

IC

A L

F Y P

CERTIFIED FINAL

A P

R

IL

PB

T

N 325 838.844

E 1 033 175.972

GENERAL SHEET NOTES

LEGEND

NEW REINFORCED CONCRETE PAD

EXISTING SECURITY FENCE

ON ALL SIDES.

EXTEND FOR A MINIMUM OF 6" FROM FACE OF EQIPMENT

ELECTRICAL EQUIPMENT USED. THE CONCRETE PAD SHALL

DETERMINED BY THE CONTRACTOR AND DIMENSIONS OF

8. ACTUAL LINEAR DIMENSIONS OF CONCRETE PAD SHALL BE

TO THE GOVERNMENT.

TO THE FENCE SHALL BE REPAIRED AT NO ADDITIONAL COST

CONCRETE OVER SECURITY FENCE. ANY DAMAGE CAUSED

CONCRETE DUCT BANK MAY ALSO BE INSTALLED BY PUMPING

AND RETENSIONED AFTER WORK IS COMPLETE.

ES101 PROVIDED SECURITY FENCE IS SPLICED TOGETHER

TO INSTALL CONCRETE DUCT BANK AS SHOWN ON SHEET

7. AN ACCESS HOLE MAY BE CUT IN THE SECURITY FENCE

WITH COMPACTED SOIL AND RIP RAP REPLACED IN KIND.

6. TRENCHES CUT IN RIP RAP DITCH SHALL BE BACKFILLED

ILLINOIS SLOPE MIXTURE.

ADJACENT AREAS WITH SEED MIX CLASS 3 NORTHERN

DISTURBED AREAS SHALL BE RESEEDED TO MATCH

COMPACTED SOIL FILL TO MATCH EXISTING GRADE.

5. TRENCHES CUT IN SOIL SHALL BE BACKFILLED WITH

AGGREGATE TO MATCH EXISTING GRADE.

COMPACTED FILL. TOP 6" SHALL BE 3/4" DENSE GRADED

4. TRENCHES CUT IN GRAVEL SHALL BE BACKFILLED WITH

CONSTRUCTED TO ELEVATION 340 (OHIO RIVER DATUM).

3. TOP OF 8" REINFORCED CONCRETE PAD SHALL BE

CONCRETE PAD AND GRADING DETAILS.

2. SEE DETAIL SHEETS CS501, ES501, AND ES502 FOR

PROVIDED BY OLMSTED OPERATIONS PERSONNEL.

1. CONSTRUCTION SHOWN BASED ON SURVEY DATA

SEE SHEET ES101

NEW ELECTRICAL LINE

A1

SCALE: 1"=60'

CS101

J J

O N

E S

J J

O N

K E

N E

T

60' 120'0

K

D O

R S

C H

S

IT

E P

L A

N

SITE PLAN

N O

R

H

(T

Y P

4000 PSI CONCRETE

CONTROL JOINT

A1

NTS

¼"

8"

AGGREGATE (DGA) SUBBASE

6" NEW DENSE GRADED

SEE NOTE #2

NEW CONCRETE PAD

WIRE FABRIC

6 X 6 - W2.9 X W2.9

GRAVEL SUBGRADE

COMPACTED

CONCRETE PAD.

5. DGA FILL SHALL EXTEND A MINIMUM OF 12" BEYOND LIMITS OF

4. ENSURE 1/8":1'-0" MAXIMUM SLOPE TO DRAIN WATER OFF OF PAD.

A MINIMUM EMBEDMENT OF 3.5".

3. STAINLESS STEEL ANCHORS FOR SUPPORT FRAME SHALL HAVE

4' INTERVALS BOTH LONGITUDINALLY AND LATERALLY.

2. CONTROL JOINTS SHALL BE SPACED AT A MINIMUM OF

CONCRETE PAD AND ENSURE 3" COVER FROM TOP OF SLAB.

1. PROVIDE 6 X 6 (W2.9 X W2.9) WIRE FABRIC FOR REINFORCEMENT OF

NOTES:

ELECTRICAL EQUIPMENT PEDESTAL

CONCRETE TRANSFORMER AND

CONCRETE TRANSFORMER AND ELECTRICAL EQUIPMENT PEDESTAL DETAILS

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

A

B

C

D

E

F

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

D

R

M A

R T

IN

L

U T

H E

R K

IN

G J

R P

L A

C E

L O

U

IS

V

IL

L E

K E

N T

U C

K Y

O L

M S

T E

D

IL

H

IG

H W

A T

E R M

O O

R

IN

G E

L E

C T

R

IC

A L

F Y P

CERTIFIED FINAL

A P

R

IL

LRL_Screen.dscriptLRL_pdf.pltcfg3:30:28 PM 3/11/2020

...\CIVIL\145870 - Outlet Works\CAD_BIM\CAD_BIM\03_Sheets\_112574_CS501.dgn

A

C S h e e tS e e d .d g n

N S I

D

O

T T

O S

C A

L E

D E

T A

IL

S

K

D O

R S

C H

J J

O N

E S

J J

O N

E S

CS501

C O

N C

R E

T E T

R A

N S

F O

R M

E R P

D

THE ROAD

DO NOT INSTALL IN

TRAFFIC RATED

PULL BOX 2' X 3' X 2' 2-WAY DUCT BANK

ON SHEET ES502 FOR

REFER TO DETAIL 2

FENCE

SEE DRAWING ON ES501

TRANSFORMER)

RECEPTACLES, 10 KVA

(PANELBOARDS, 4-PIN

EQUIPMENT PEDESTAL

D/S HARBOR POWER

FENCE

FENCE

RATED 45E AMPS.

FURNISH 3 S&C SMU-20 FUSES,

KV-NOMINAL = 14.4

SWITCH GEAR S&C PMH-9D,

EXISTING PAD MOUNTED

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

A

B

C

D

E

F

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

D

R

M A

R T

IN

L

U T

H E

R K

IN

G J

R P

L A

C E

L O

U

IS

V

IL

L E

K E

N T

U C

K Y

O L

M S

T E

D

IL

H

IG

H W

A T

E R M

O O

R

IN

G E

L E

C T

R

IC

A L

F Y P

CERTIFIED FINAL

A P

R

IL

PB

T

GENERAL SHEET NOTES

LEGEND

POLE MOUNTED LIGHT FIXTURE

PULLBOX

TRANSFORMER

PANELBOARD (2)

SURFACE MOUNTED

CONTAINS THE FOLLOWING DOWNSTREAM (D/S) POWER EQUIPMENT:

UNDERGROUND PRIMARY ELECTRICAL

8. SEE SHEET ES503 FOR LIGHT MOUNTING DETAIL.

SHALL BE FIELD SWEEP 90'S.

ALL UNDERGROUND PRIMARY ELECTRIC CABLE BENDS 7.

CROSSING.

UTILITY LINES, AND 12" OF VERTICAL SEPARATION WHEN

MAINTAIN 24" OF HORIZONTAL SEPARATION FROM OTHER

ALL PRIMARY UNDERGROUND ELECTRICAL LINES SHALL 6.

MATERIAL OR REPLACED WITH NEW.

RETAINED AND REINSTALLED FOR THE TOP 6" OF SURFACE

TO 10' DEEP. GOOD QUALITY 3/4" AGGREGATE SHALL BE

BE ALL IN GRAVEL FILL AND WASTE ROCK OR CONCRETE UP

DUCTBANK PATH FORM TRANSFORMER TO PULLBOX SHALL 5.

COORDINATE ANY NEW WORK WITH EXISTING.

REPAIR OF ANY DAMAGE RESULTING FROM FAILURE TO

AND NEW UTILITIES. CONTRACTOR IS RESPONSIBLE FOR

BELOW GRADE. COORDINATE INSTALLATION WITH EXISTING

ALL CIRCUITS SHALL BE INSTALLED A MINIMUM OF 36" 4.

FENCE AS SHOWN.

DUCTBANK SHALL BE INSTALLED ON THE OUTSIDE OF 3.

IS AT TERMINALS IN BAY 3.

2. POINT OF CONNECTION TO EXISTING SWITCH GEAR PMH-9D

ES503.

FOR ELECTRICAL DETAILS REFER TO ES501 THROUGH 1.

A1

N O

R

TH

P

LA

N

SCALE: 1"=60'

ES101

S

K E

N E

K E

N E

K E

N E

T T

ELECTRICAL SITE PLAN

E L E

C T

R

IC

A L S

IT

E P

L

W A

L T

E R

S

PARKING LOT

MAINTENANCE BUILDING

FACILITY

WICKET GATE

BUILDING

STORAGE

60' 120'0

ES502

PB

6'-0"

7'-0"

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

A

B

C

D

E

F

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

D

R

M A

R T

IN

L

U T

H E

R K

IN

G J

R P

L A

C E

L O

U

IS

V

IL

L E

K E

N T

U C

K Y

O L

M S

T E

D

IL

H

IG

H W

A T

E R M

O O

R

IN

G E

L E

C T

R

IC

A L

F Y P

CERTIFIED FINAL

A P

R

IL

D

A

B

Y

C

C

DESCRIPTION

VA OR W BREAKER

POLE A

BREAKER

POLE A

VA OR W

DESCRIPTION

TOTAL 1

TOTAL 2

TOTAL 1 + 2

TOTAL 2

1 2

3 4

5 6

7 8

9 10

11 12

13 14

15 16

CKT

NO.

BUS

CONN

CKT

NO.A B A B

PHASE A CURRENT:

PHASE B CURRENT:

.TOTAL PANEL kVA:

TOTAL PANEL CURRENT:

PANEL SOURCE:

NOTES:

LOCATION:

B

D

DESCRIPTION

VA OR W BREAKER

POLE A

BREAKER

POLE A

VA OR W

DESCRIPTION

TOTAL 1

TOTAL 2

TOTAL 1 + 2

TOTAL 2

1 2

3 4

5 6

7 8

9 10

11 12

13 14

15 16

CKT

NO.

BUS

CONN

CKT

NO.A B A B

PHASE A CURRENT:

PHASE B CURRENT:

.TOTAL PANEL kVA:

TOTAL PANEL CURRENT:

NOTES:

LOCATION:

SPARE

1RECEPTACLE 180 20

2 30

SPARE 2 30

SPARE20

1 20 SPARE

1 20 SPARE

1 SPARE20

C C

D

G

7 F6

F

G

76800

76800

76800

76800

76800

76800

10 KVA TRANSFORMER

2 204000 a gfi(provide with 30 m

(1) 4-pin receptacle (2) 4-pin receptacle

(provide with 30 ma gfi

480V 480V

SIDE VIEW FRONT VIEW

200A

1/4" STEEL BACK PLATE

200A

CABLE TROUGH

PANEL

480/277 V

PANEL

240/120 V

2" ANGLE

WITH 3/4" TEXT (TYP)

IDENTIFICATION TAG

H E

IG

H T

M O

U N

T

IN

G

R E

C E

P T

A C

L E

M

IN

IM

U M

V

O L T

/2

V

O L T

MANUAL OVERRIDE

BOX

PULL

480/277V PANEL 240/120V PANEL

D/S LIGHT FIXTURE 180 20

(TYP)

DISCONNECTS

NON-FUSED

BREAKER.

(1) 20 A, 2 POLE; AND (1) 20 A, SINGLE POLE CIRCUIT

RECEPTACLES;(2) EA 30 A, 2 POLE CIRCUIT BREAKER;

PHASE, GFI 30 mA CIRCUIT BREAKER FOR 4-PIN

NEMA 3R ENCLOSURE. PROVIDE (2) EA 200 A, 3

SEE LOCATION ON ES101.

CONTROL AND MOTION SENSOR

LED LIGHT FIXTURE W/ PHOTOCELL

EQUIPMENT SCHEDULE

MARK DESCRIPTION REMARKS

4-500 KCMIL + 2/0 GND

2" RGS CONDUIT

MARK

CONDUCTOR SCHEDULE

REMARKSDESCRIPTION

3/4" RGS CONDUIT

2-#12,+1-#12 GND 3/4" RGS CONDUIT

2-#10,+1-#10 GND

3-3/0 KCMIL + #6 GND

3/4" RGS CONDUIT

EQUIPMENT LOCATED IN PEDESTAL.

REQUIRE TO ACCOMMODATE ALL

3. FIELD VERIFY FRAME MEASUREMENT

3. ALL PVC CONDUIT IS SCHEDULE 80.

2. ALL DISCONNECTS ARE LOAD RATED.

UNLESS OTHERWISE NOTED.

1. ALL EQUIPMENT RATED NEMA 3R

NOTES:

ANGLE FRAME

4"x4"x1/2" WELDED

E

B g f

C

SEE DETAIL ON SHEET ES503.

TRANSFORMER

300 KVA PADMOUNT

300 kva transformer

D/S HARBOR POWER EQUIPMENT PEDESTAL

D/S HARBOR POWER EQUIPMENT PEDESTAL

+1- #2 GND

SHIELDED, LDPE JACKET,

EPR INSULATED,

3-#2 COPPER, 5 KV, 133%,

MAINS RATING:

MAINS TYPE:MAIN CB

A.I.C. RATING: 65,000 AMPS SYMMETRICAL

MCB RATING:

PANEL SOURCE:

MAINS RATING:

MAINS TYPE:

A.I.C. RATING:

MCB RATING:

10,000 AMPS SYMMETRICAL

MLO

100 aMPS 400 aMPS

400 aMPS

10 kva transformer

FILLED, DEAD FRONT TRANSFORMER

4.16KV-480/277 V, DELTA-WYE, 300 KVA, OIL

LIGHTING ARRESTOR LOAD BREAK ELBOWS.

RELIEF VALVE, DRAIN VALVE FOR SAMPLING AND

LIQUID LEVEL, TEMPERATURE GAUGE, PRESSURE

WITH DOUBLE BUSHING INSERTS, COPPER WOUND,

PADMOUNT TRANSFORMER IS RADIAL FEED TYPE

PEDESTAL

D/S HARBOR POWER EQUIPMENT

2-#12,+1-#12 GND

E

UPSTREAM.

RECEPTACLES MATCH EXISTING EQUIPMENT

SEE DETAIL 1 ON THIS SHEET. VERIFY PLUGS AND

MATCH EXISTING EQUIPMENT UPSTREAM.

D D

E

E

DUCT TO 300 KVA TRANSFORMER

4" PVC, CONCRETE ENCASED

FIXTURE

MOUNTED

CONDUIT

LED

DISCONNECT SWITCH

480 V, 200 AMP, NON-FUSED, HEAVY DUTY

GFCI DUPLEX RECEPTACLE

120 V WEATHERPROOF-IN-USE

GFCI DUPLEX RECEPTACLE

120 V WEATHERPROOF-IN-USE

PHASE, DRY TYPE TRANSFORMER

V SEC. SINGLE 0/240 10 KVA, 480 V PRIMARY, 12

SINGLE PHASE

100 A MLO PANELBOARD, 120/240 V, 3 WIRE

(BASIS OF DESIGN)

ADR20034 RECEPTACLE AND JUNCTION BOX

2-#6,+1-#10 GND

DIFFERENT EQUIPMENT IS PROVIDED.

FROM CONTRACTING OFFICER IS REQUIRED IF

DIFFERENT MANUFACTURER. HOWEVER, APPROVAL

FROM SELECTING EQUIVALENT EQUIPMENT FROM

BASIS OF DESIGN DOES NOT PROHIBIT CONTRACTOR 1.

NOTES:

PMH-9

EXISTING

SWITCH

SECTIONALIZING

EXISTING

COMPARTMENT 3

FURNISH 45E FUSE FOR

S&C PMH-9

HIGH VOLTAGE SWITCH

EXISTING

EQUIPMENT PEDESTAL SHALL BE GALVANIZED STEEL.8.

THE MACHINE BOLTS ARE STAINLESS STEEL.7.

3.5 INCHES.

THE STAINLESS STEEL EXPANSION ANCHORS SHALL HAVE A MINIMUM EMBEDMENT OF 6.

ALL SUPPORTS ARE 4" STEEL CHANNEL5.

COMPATIBLE WITH EXISTING EQUIPMENT UPSTREAM.

THE PIN & SLEEVE RECEPTACLES ARE 480 V (3 PHASE AND 1 GND) AND SHALL BE 4.

BUSHING AS REQUIRED.

BE LOCKNUT. THE OUTSIDE LOCKNUT SHALL BE A SEALING TYPE LOCKNUT. GROUNDING

HUB WITH INSULATED THROAT. CONDUITS ENTERING BOTTOM OF ENCLOSURES SHALL

CONDUITS ENTERING TOP OR SIDES OF ENCLOSURES SHALL BE STRAIGHT WATERTIGHT 3.

ALL ENCLOSURES SHALL BE NEMA TYPE 3R OR 4.2.

SEE DRAWING ES503 FOR LIGHTING.1.

NOTES:

SHALL BE GRC.

ALL CONDUIT ABOVE GRADE

TO 300 KVA TRANSFORMER.

CONDUIT (GRC) SWEEPS

GALVANIZED RIGID STEEL

4" SCH 80 PVC CONDUIT WITH

TO GROUND

BOND NEUTRAL

SWEEPS AND ABOVE GRADE.

4" PVC CONDUIT. BELOW GRADE GRC

3/4" GRC CONDUIT

MCB SE RATED

480/277 V PANELBOARD, 400 A

2 POLE AND (4) EA 20 A, 1 POLE.

BREAKER FOR DUPLEX GFCI RECEPTACLE;(2) EA 30 A,

NEMA 3R ENCLOSURE. PROVIDE 1 POLE, 20 A CIRCUIT

ES501

S

K E

N E

K E

N E

K E

N E

W A

L T

E R

S

E L E

C T

R

IC

A L S

IT

E D

E T

A

IL

N.T.S

HARBOR AREA POWER ONE-LINE DIAGRAM

N.T.S

2D/S HARBOR POWER EQUIPMENT PEDESTAL

D/S HARBOR AREA POWER PANEL SCHEDULES

14'

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

A

B

C

D

E

F

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

D

R

M A

R T

IN

L

U T

H E

R K

IN

G J

R P

L A

C E

L O

U

IS

V

IL

L E

K E

N T

U C

K Y

O L

M S

T E

D

IL

H

IG

H W

A T

E R M

O O

R

IN

G E

L E

C T

R

IC

A L

F Y P

CERTIFIED FINAL

A P

R

IL

PAINTED SAFETY YELLOW

WITH CONCRETE FILL,

6" SCH. 80 STEEL PIPE

GROUND OR FILL

TOP OF EXISTING

(SPARE CONDUIT)

PULLSTRING

FROM MAT.

RING. PLACE 36" MINIMUM

#2 AWG MINIMUM GROUND

PAD ON ALL SIDES

A MINIMUM OF 12" BEYOND

GRAVEL FILL. EXTEND

EQUIPMENT ON ALL SIDES

A MINIMUM OF 6" BEYOND

CONCRETE PAD. EXTEND

5KV CABLES

+1-#2 GROUND,

3-#2 SHIELDED

ENCASEMENT

CONCRETE

CONDUIT

2-4" SCH 80 PVC

DETAIL THIS SHEET

BOLLARD, SEE

DETAIL THIS SHEET

BOLLARD, SEE

SECTION

TRANSFORMER

RESILIENT SEALANT

SEAL AROUND BASE WITH

18" BELOW GRADE (TYP)

CLAD STEEL GROUND ROD

" X 10' LONG COPPER-4

GROUND AND CABLE SHIELDS

SURGE ARRESTERS, ENCLOSURE

GROUNDING CONDUCTORS FOR

CONCRETE FILL

3"3"

14"

3"

ELEVATION

PLAN

GRAVEL FILL

PRIMARY VOLTAGE SECTION

TYP.

12"

GROUND ROD (TYP)

T Y P

(D E

T A

IL

O

N S

H E

E T E

S

D /S H

A R

B O

R P

O W

E R E

Q U

IP

M E

N T P

E D

E S

T A

L

UP TO 3" MATERIAL.

329 TO 339 IS FILLED WITH WASTE GRAVEL IN VARIOUS GRADATIONS,

CONCRETE SLABS BURIED 10' DOWN, AND THE FILL FROM ELEVATION

WHEN DRIVING THE GROUND ROD DOWN, BE ADVISED THAT THERE ARE 2.

VERIFY BUSHING ON 300 KVA TRANSFORMER.1.

NOTES:

PANELBOARD

CONNECTION TO 480 V

SECONDARY CONDUIT

(1) 4" SCH 80 PVC CONDUIT

8" CONCRETE PAD

SECTION

VOLTAGE

SECONDARY

ENCASED DUCT

CONCRETE

CONDUITS IN

PRIMARY

300 KVA TRANSFORMER

2/0 AWG MINIMUM

NEUTRAL TO GROUND.

BOND THE SECONDARY

WITH 2/0.

CONNECT TO GROUND

GRC SWEEP

GRC ABOVE GRADE

ADD REBAR UNDER ROADWAY.

TO TRANSFORMER.

DUCT FROM EXISTING SWITCH

INSTALL CONCRETE ENCASED

ES502

S

K E

N E

K E

N E

K E

N E

W A

L T

E R

S

E L E

C T

R

IC

A L S

IT

E D

E T

A

POWER DUCT BANK

BOLLARD DETAIL

1/2"=1'

N.T.S

PADMOUNT TRANSFORMER AND D/S HARBOR POWER EQUIPMENT PEDESTAL DETAIL

2 3/4 "

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

A

B

C

D

E

F

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

D

R

M A

R T

IN

L

U T

H E

R K

IN

G J

R P

L A

C E

L O

U

IS

V

IL

L E

K E

N T

U C

K Y

O L

M S

T E

D

IL

H

IG

H W

A T

E R M

O O

R

IN

G E

L E

C T

R

IC

A L

F Y P

CERTIFIED FINAL

A P

R

IL

FRONT VIEW

SLIP FITTING

STEEL BOLT

1/2" DIA STAINLESS

SIDE VIEW

2-1/2" RGS CONDUIT

STEEL PLATE

ATTACHED TO BACK OF

UNISTUT & CLAMPS

PLATE

STEEL

PEDESTAL

MOUNTED AT 10' AFF

PROVIDED.

OFFICER IS REQUIRED IF DIFFERENT LIGHT FIXTURE IS

MANUFACTURER. HOWEVER, APPROVAL FROM CONTRACTING

SELECTING EQUIVALENT FIXTURE FROM A DIFFERENT

BASIS OF DESIGN DOES NOT PROHIBIT CONTRACTOR FROM 2.

LED-P1-40K-T2M-MVOLT.

BASIS OF DESIGN IS LITHONIA/ACUITY DSX0-

LIGHT FIXTURE IS 38 WATT, 277 V, LED WITH ALUMINUM FINISH. 1.

NOTES:

ES503

S

K E

N E

K E

N E

K E

N E

W A

L T

E R

S

E L E

C T

R

IC

A L S

IT

E D

E T

A

LIGHT MOUNTING DETAIL

1"=1'

Section 00 21 00 - Instructions

CLAUSES INCORPORATED BY REFERENCE

52.204-16 Commercial and Government Entity Code Reporting JUL 2016 52.204-18 Commercial and Government Entity Code Maintenance JUL 2016 52.222-5 Construction Wage Rate Requirements--Secondary Site of the

Work

MAY 2014

252.204-7008 Compliance With Safeguarding Covered Defense Information Controls

OCT 2016

CLAUSES INCORPORATED BY FULL TEXT

52.222-23 NOTICE OF REQUIREMENT FOR AFFIRMATIVE ACTION TO ENSURE EQUAL

EMPLOYMENT OPPORTUNITY FOR CONSTRUCTION (FEB 1999)

(a) The offeror's attention is called to the Equal Opportunity clause and the Affirmative Action Compliance Requirements for Construction clause of this solicitation.

(b) The goals for minority and female participation, expressed in percentage terms for the Contractor's aggregate workforce in each trade on all construction work in the covered area, are as follows:

Goals for minority participation for each trade

Goals for female participation for each trade

18.4% 6.9%

These goals are applicable to all the Contractor's construction work performed in the covered area. If the Contractor performs construction work in a geographical area located outside of the covered area, the Contractor shall apply the goals established for the geographical area where the work is actually performed. Goals are published periodically in the Federal Register in notice form, and these notices may be obtained from any Office of Federal Contract Compliance Programs office.

(c) The Contractor's compliance with Executive Order 11246, as amended, and the regulations in 41 CFR 60-4 shall be based on (1) its implementation of the Equal Opportunity clause, (2) specific affirmative action obligations required by the clause entitled "Affirmative Action Compliance Requirements for Construction,'' and (3) its efforts to meet the goals. The hours of minority and female employment and training must be substantially uniform throughout the length of the contract, and in each trade. The Contractor shall make a good faith effort to employ minorities and women evenly on each of its projects. The transfer of minority or female employees or trainees from Contractor to Contractor, or from project to project, for the sole purpose of meeting the Contractor's goals shall be a violation of the contract, Executive Order 11246, as amended, and the regulations in 41 CFR 60-4. Compliance with the goals will be measured against the total work hours performed.

(d) The Contractor shall provide written notification to the Deputy Assistant Secretary for Federal Contract Compliance, U.S. Department of Labor, within 10 working days following award of any construction subcontract in excess of $10,000 at any tier for construction work under the contract resulting from this solicitation. The notification shall list the --

(1) Name, address, and telephone number of the subcontractor;

(2) Employer's identification number of the subcontractor;

(3) Estimated dollar amount of the subcontract;

(4) Estimated starting and completion dates of the subcontract; and

(5) Geographical area in which the subcontract is to be performed.

(e) As used in this Notice, and in any contract resulting from this solicitation, the "covered area" is [Contracting Officer shall insert description of the geographical areas where the contract is to be performed, giving the State, county, and city].

(End of provision)

52.225-10 NOTICE OF BUY AMERICAN REQUIREMENT--CONSTRUCTION MATERIALS (MAY 2014)

(a) Definitions. “Commercially available off-the-shelf (COTS) item,” “construction material,” “domestic construction material,” and “foreign construction material,” as used in this provision, are defined in the clause of this solicitation entitled “Buy American --Construction Materials” (Federal Acquisition Regulation (FAR) clause 52.225-9).

(b) Requests for determinations of inapplicability. An offeror requesting a determination regarding the inapplicability of the Buy American statute should submit the request to the Contracting Officer in time to allow a determination before submission of offers. The offeror shall include the information and applicable supporting data required by paragraphs (c) and (d) of the clause at FAR 52.225-9 in the request. If an offeror has not requested a determination regarding the inapplicability of the Buy American statute before submitting its offer, or has not received a response to a previous request, the offeror shall include the information and supporting data in the offer.

(c) Evaluation of offers. (1) The Government will evaluate an offer requesting exception to the requirements of the Buy American statute, based on claimed unreasonable cost of domestic construction material, by adding to the offered price the appropriate percentage of the cost of such foreign construction material, as specified in paragraph (b)(3)(i) of the clause at FAR 52.225-9.

(2) If evaluation results in a tie between an offeror that requested the substitution of foreign construction material based on unreasonable cost and an offeror that did not request an exception, the Contracting Officer will award to the offeror that did not request an exception based on unreasonable cost.

(d) Alternate offers.

(1) When an offer includes foreign construction material not listed by the Government in this solicitation in paragraph (b)(2) of the clause at FAR 52.225-9, the offeror also may submit an alternate offer based on use of equivalent domestic construction material.

(2) If an alternate offer is submitted, the offeror shall submit a separate Standard Form 1442 for the alternate offer, and a separate price comparison table prepared in accordance with paragraphs (c) and (d) of the clause at FAR 52.225-9 for the offer that is based on the use of any foreign construction material for which the Government has not yet determined an exception applies.

(3) If the Government determines that a particular exception requested in accordance with paragraph (c) of the clause at FAR 52.225-9 does not apply, the Government will evaluate only those offers based on use of the equivalent domestic construction material, and the offeror shall be required to furnish such domestic construction material. An offer based on use of the foreign construction material for which an exception was requested--

(i) Will be rejected as nonresponsive if this acquisition is conducted by sealed bidding; or

(ii) May be accepted if revised during negotiations.

52.233-2 SERVICE OF PROTEST (SEP 2006)

(a) Protests, as defined in section 33.101 of the Federal Acquisition Regulation, that are filed directly with an agency, and copies of any protests that are filed with the Government Accountability Office (GAO), shall be served on the Contracting Officer (addressed as follows) by obtaining written and dated acknowledgment of receipt from

U.S. Army Corps of Engineers CELRL, Heather Bauer Room 821 600 Dr. Martin Luther King Jr. Place Louisville, KY 40202

(b) The copy of any protest shall be received in the office designated above within one day of filing a protest with the GAO.

52.236-27 SITE VISIT (CONSTRUCTION) (FEB 1995)

(a) The clauses at 52.236-2, Differing Site Conditions, and 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation. Accordingly, offerors or quoters are urged and expected to inspect the site where the work will be performed.

(b) Site visits may be arranged during normal duty hours by contacting:

William Gilmour Olmsted Lock and Dam 567 New Dam Road Olmsted, IL 62970

(618) 748-6416

52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB 1998)

This solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. The offeror is cautioned that the listed provisions may include blocks that must be completed by the offeror and submitted with its quotation or offer. In lieu of submitting the full text of those provisions, the offeror may identify the provision by paragraph identifier and provide the appropriate information with its quotation or offer. Also, the full text of a solicitation provision may be accessed electronically at this/these address(es):

https://www.acquisition.gov/content/far https://www.acq.osd.mil/dpap/ (DFARS)

Section 00 45 00 - Representations and Certifications

REPS AND CERTS

COMPANY NAME AND ADDRESS: _______________________________________

PHONE NUMBER ________________ FAX NUMBER ________________

EMAIL ADDRESS ______________________________________________________

BUSINESS SIZE (select one) Large Business _____ Small Business_____ HUBZone Business_____ 8A _____ Woman-Owned ____ Service-Disabled Veteran-Owned ____ Contractor is registered with SAM: _____ YES _____ NO (See FAR 52.204-7)

TAX ID # ______________________

INDICATE Unique Entity Identifier (previously DUNS NUMBER) ____________

CAGE NO. _________

(Note: Unique Entity Identifier (FAR 52.204-7) is a 9 digit numeric code.)

52.203-19 Prohibition on Requiring Certain Internal Confidentiality

Agreements or Statements

JAN 2017

52.204-19 Incorporation by Reference of Representations and Certifications.

DEC 2014

52.204-8 ANNUAL REPRESENTATIONS AND CERTIFICATIONS (JAN 2020)

(a)(1) The North American Industry Classification System (NAICS) code for this acquisition is 238210.

(2) The small business size standard is $16,500,000.

(3) The small business size standard for a concern which submits an offer in its own name, other than on a construction or service contract, but which proposes to furnish a product which it did not itself manufacture, is 500 employees.

(b)(1) If the provision at 52.204-7, System for Award Management, is included in this solicitation, paragraph (d) of this provision applies.

(2) If the provision at 52.204-7, System for Award Management, is not included in this solicitation, and the Offeror has an active registration in the System for Award Management (SAM), the Offeror may choose to use paragraph (d) of this provision instead of completing the corresponding individual representations and certifications in the solicitation. The Offeror shall indicate which option applies by checking one of the following boxes:

( ) Paragraph (d) applies.

( ) Paragraph (d) does not apply and the offeror has completed the individual representations and certifications in the solicitation.

(c) (1) The following representations or certifications in SAM are applicable to this solicitation as indicated:

(i) 52.203-2, Certificate of Independent Price Determination. This provision applies to solicitations when a firm-fixed-price contract or fixed-price contract with economic price adjustment is contemplated, unless—

(A) The acquisition is to be made under the simplified acquisition procedures in Part 13;

(B) The solicitation is a request for technical proposals under two-step sealed bidding procedures; or

(C) The solicitation is for utility services for which rates are set by law or regulation.

(ii) 52.203-11, Certification and Disclosure Regarding Payments to Influence Certain Federal Transactions. This provision applies to solicitations expected to exceed $150,000.

(iii) 52.203-18, Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements--Representation. This provision applies to all solicitations.

(iv) 52.204-3, Taxpayer Identification. This provision applies to solicitations that do not include the provision at 52.204-7, System for Award Management.

(v) 52.204-5, Women-Owned Business (Other Than Small Business). This provision applies to solicitations that—

(A) Are not set aside for small business concerns;

(B) Exceed the simplified acquisition threshold; and

(C) Are for contracts that will be performed in the United States or its outlying areas.

(vi) 52.204-26, Covered Telecommunications Equipment or Services--Representation. This provision applies to all solicitations.

(vii) 52.209-2; Prohibition on Contracting with Inverted Domestic Corporations--Representation.

(viii) 52.209-5; Certification Regarding Responsibility Matters. This provision applies to solicitations where the contract value is expected to exceed the simplified acquisition threshold.

(ix) 52.209-11, Representation by Corporations Regarding Delinquent Tax Liability or a Felony Conviction under any Federal Law. This provision applies to all solicitations.

(x) 52.214-14, Place of Performance--Sealed Bidding. This provision applies to invitations for bids except those in which the place of performance is specified by the Government.

(xi) 52.215-6, Place of Performance. This provision applies to solicitations unless the place of performance is specified by the Government.

(xii) 52.219-1, Small…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .