This federal contract solicitation seeks proposals for Project Number 87539, the SOF Operations Facility Secure Work Area. The solicitation involves renovating an existing facility into a secure work area meeting ICD 705 requirements. Scope of work includes private and semi-private offices, expanded latrines, a 120-person classroom, VTC spaces, and an upgraded HVAC system. Facilities must meet STC-50 standards for walls, doors, ceilings and floors include fire suppression, alarm, and mass notification systems. Installation of cybersecurity, identity assurance, operational resilience, fire and life safety systems, building automation systems, electronic access control, integrated security systems, cable TV, and energy management connectivity are required. Access for individuals with disabilities and sustainability/energy measures and building information systems are also included. The existing facility has a composite concrete floor slab and steel rigid frame structure. The project budget is between $1,000,000 and $5,000,000. This is a 100% Small Business Set-Aside solicitation by the U.S. Army Corps of Engineers Engineering District Wilmington.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation No: W912PM19R0019 Project Number PN 87539
Amendment 0007
TECHNICAL SUMMARY OF CHANGES
A. SPECIFICATIONS:
PROJECT TABLE OF CONTENTS
Replace Project Table of Contents in its entirety.
01 20 00.00 20 – PRICE AND PAYMENT PROCEDURES
Delete existing Page 1 through Page 6 in their entirety.
B. DRAWINGS:
Delete Sheets AD101, AE101, AE502, AE504, AE601, AND G-004 in their entirety and replace with revised enclosed Sheets.
Encls As stated
SOF Operations Facility, SOTF Solicitation No: TBD Fort Bragg, NC Project Number PN 87539
PROJECT TABLE OF CONTENTS
DIVISION 01 - GENERAL REQUIREMENTS
01 00 05 GENERAL AND SPECIAL PROVISIONS
01 00 60 SECURITY PROCEDURES GUIDE
01 11 00 SUMMARY OF WORK
01 14 00 WORK RESTRICTIONS
01 20 00.00 20 PRICE AND PAYMENT PROCEDURES
01 30 00 ADMINISTRATIVE REQUIREMENTS
01 32 01.00 10 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
01 33 29 SUSTAINABILITY REPORTING
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 QUALITY CONTROL
01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE(RMS CM)
01 45 35 SPECIAL INSPECTIONS
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
01 57 19.00 37 INDOOR AIR QUALITY (IAQ) MANAGEMENT
01 58 00 PROJECT IDENTIFICATION
01 74 19.00 37 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
01 78 00 CLOSEOUT SUBMITTALS
01 78 23 OPERATION AND MAINTENANCE DATA
01 78 24.00 10 FACILITY DATA REQUIREMENTS
01 91 00.00 37 COMMISSIONING
DIVISION 02 - EXISTING CONDITIONS
02 41 00 DEMOLITION
DIVISION 05 - METALS
05 50 13 MISCELLANEOUS METAL FABRICATIONS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 21 16 BLANKET INSULATION
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 11 16 ALUMINUM FRAMES
08 14 73 SLIDING WOOD DOORS
08 34 97 SCIF DOOR ASSEMBLIES
08 71 00 DOOR HARDWARE
DIVISION 09 - FINISHES
09 22 00 SUPPORTS FOR GYPSUM BOARD
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC TILING
09 51 00 ACOUSTICAL CEILINGS
PROJECT TABLE OF CONTENTS Page 1
FOUO
****Amendment 0007****
**** Amendment 0007****
**** Amendment 0007****
Solicitation No: W912PM19R0019
09 65 00 RESILIENT FLOORING
09 68 00 CARPETING
09 69 23 LOW-PROFILE ACCESS FLOORING
09 90 00 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 22 39 FOLDING PANEL PARTITIONS
10 28 13 TOILET ACCESSORIES
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
22 07 19.00 40 PLUMBING PIPING INSULATION
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 01 30.41 HVAC SYSTEM CLEANING
23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS
23 05 15 COMMON PIPING FOR HVAC
23 05 48.00 40 VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND
EQUIPMENT
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.01 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER
BUILDING CONTROL SYSTEMS
23 73 13.00 40 MODULAR CENTRAL-STATION AIR-HANDLING UNITS
DIVISION 25 - INTEGRATED AUTOMATION
25 05 11 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS
25 08 10 UTILITY MONITORING AND CONTROL SYSTEM TESTING
25 10 10 UTILITY MONITORING AND CONTROL SYSTEM (UMCS) FRONT END
AND INTEGRATION
DIVISION 26 - ELECTRICAL
26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS
26 05 00.00 40 COMMON WORK RESULTS FOR ELECTRICAL
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 24 16.00 40 PANELBOARDS
26 51 00 INTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 10 24 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 08 10 ELECTRONIC SECURITY SYSTEM ACCEPTANCE TESTING
PROJECT TABLE OF CONTENTS Page 2
FOUO
Solicitation No: TBDSolicitation No: W912PM19R0019
28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS)
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 3
FOUO
****Amendment 0007****
Solicitation No: TBDSolicitation No: W912PM19R0019
H F.5 E
19.6
D C.3 C B A
20.7
21.8
22.7
23.5
D.6
36'-0"
36'-0"10'-0"26'-0"36'-0"
11'-4"
32'-0"31'-7"
CENTERLINE OF
ROOF PEAK
S L
O P
E
F L
A T
R
O O
F
S L
O P
E
CENTERLINE OF
ROOF PEAK
S L
O P
E
S L
O P
E
F L
O
F
CHASE
TEL
ELEC
CORR
MECH
AREA NIC
42024201
4220 4220
OFFICE
CORRIDOR
OFFICE
COMM
C O
R R
I D
O R
O P
E N
B
E L O
W
6301 6302 6303 6304 6305
AREA NIC AREA NIC AREA NIC
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
O
C
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
Y
D
E
W P
M R
X X
X X
X X
X
X X
X
X X
X
D E
S
I P
T I O
N
J O
N E
S
F
R A
N K
L
D
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
F
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
P
E
N G
I N
E E
R S
R
L I N
G T
V E
W I L M
I N
G T
O N
N
O R
H
R
O L I N
A
F O
B
A
G G
N
O R
R
O L
I N
A
S O
F
O
P E
R A
T I O
C
I L
I T
Y
S
O T
F
AD101
F L
O O
R
P
L A
N
D
E M
O L
I T
I O
N
T
F
E R
Y
M
B
E N
N E
T T
T
F
E R
Y
K
B
R O
D B
E R
A D
D
G N
EXIST SCREEN
WALL BELOW
AD101
FLOOR PLAN - DEMOLITION
1/8" - 1'-0'
PLAN
NORTH
T
R
U
E
N
O
R
T
H
BUILDING KEY PLAN
PROJECT
LOCATION
NOT TO SCALE
DEMOLITION LEGEND
EXISTING TO REMAIN
TEMPORARY CONSTRUCTION &
DUST CONTROL WALL AND CEILING
EXISTING INTERIOR CMU
ASSEMBLY TO BE REMOVED
EXISTING EXTERIOR CMU
ASSEMBLY TO REMAIN
EXISTING METAL STUD & GYP
BD WALLS TO BE REMOVED
EXISTING DOOR & FRAME
ASSEMBLY TO BE REMOVED
GENERAL NOTES:
1. SEE MECHANICAL AND ELECTRICAL SHEETS FOR
THE REMOVAL AND REPLACEMENT OF EQUIPMENT,
PIPING, DEVICES, LIGHTING FIXTURES, ETC.
2. EQUIPMENT AND FIXTURES NOT SHOWN FOR
CLARITY.
3. ALL EXIST DOORS REMOVED DURING DEMOLITION
SHALL BE SALVAGED AND TURNED OVER TO THE
GOV'T, TYP
4. EXIST DEMOUNTABLE WALLS AND FURNITURE TO
BE REMOVED BY THE GOV'T IN THE PROJECT AREA
DEMOLITION NOTES
CUT OPENING IN EXISTING CMU WALL ASSEMBLIES FOR
NEW DOOR & FRAME ASSEMBLY
EXISTING DOOR AND FRAME TO REMAIN AND PREPPED
FOR REFINISHING ON CORRIDOR 4003 SIDE
DEMO EXIST WALL ASSEMBLY FOR PROPOSED 16 GA,
STEEL, CASED OPENING (3'-0"W x 6'-8"H). CONTRACTOR
TO COORDINATE ACTUAL LOCATION W/ THE GOV'T
REMOVE (3) ROWS OF EXIST 1x6 WOOD RAIL COMPLETE, BOTH SIDES OF CORRIDOR (APPROX 500 LF). PATCH
ANCHOR HOLES TO MATCH ADJACENT FINISH PRIOR TO
PAINTING
EXISTING FLOOR FINISH TO REMAIN INTACT.
CONTRACTOR SHALL PROTECT DURING CONSTRUCTION
& CLEAN UPON COMPLETION OF CONSTRUCTION
EXISTING STAIR ASSEMBLY TO REMAIN INTACT AND
ACCESSIBLE FOR THE DURATION OF THE PROJECT
CONTRACTOR SHALL INSTALL A DUST PARTITION IN
LOCATION SHOWN OR AT THE DIRECTION OF THE
CONTRACTING OFFICER'S REPRESENTATIVE
DEMOLISH 6" CMU WALL ASSEMBLY FROM FLOOR TO
ROOF SYSTEM COMPLETE. REFER TO INTERIOR
ELEVATION FOR FURTHER INFO. GRIND SMOOTH
EXISTING REBAR OR ANCHORS THAT REMAIN FLUSH TO
THE SURFACE
DEMOLISH WINDOW ASSEMBLY
EXISTING DEMOUNTABLE WALLS TO BE REMOVED BY
THE GOV'T PRIOR TO CONSTRUCTION
EXISTING DOOR LEAF AND FRAME TO BE REMOVED.
PREP OPENING FOR NEW FRAME, DOOR LEAF, AND
HARDWARE FOR EXITING ONLY
REMOVE EXISTING DOOR & FRAME ASSEMBLY.
PREP OPENING FOR NEW STUD & GWB IN-FILL
CUT OPENINGS IN EXISTING CMU WALL ASSEMBLIES
AS REQ'D FOR MECHANICAL DUCTS, SEE
STRUCTURAL AND MECHANICAL DRAWINGS
REMOVE TOILET PARTITIONS, ACCESSORIES, WALL
AND FLOOR TILE, FIXTURES AND DRAINS COMPLETE.
REMOVE AND MODIFY PIPING AS REQ'D PER PLUMBING
DRAWINGS. PREP EACH RESTROOM FOR NEW FLOOR
DRAINS
STRUCTURAL STEEL FRAMING AS OCCURS BELOW
CONCRETE FLOOR SLAB (ALL FRAMING NOT SHOWN FOR
CLARITY). CONTRACTOR TO VERIFY LOCATIONS OF ALL
FRAMING PRIOR TO ANY DEMOLITION
REMOVE MORTAR BED DOWN TO STRUCTURAL SLAB.
PREP AND FILL DEPRESSED SLAB WITH CEMENTITIOUS
MATERIAL USED FOR PATCHING OF CONCRETE
SURFACES. WORK LEVEL TO SURROUNDING SLAB
ELEVATION
4 4
TYP
AD301
AD301
EXIST OPENING
@ COUNTER
TYP
TYP
TYP
TYP
TYP
TYP
A
M E
N D
M E
M
3/3/2020
H F.5 E
19.6
D C.3 C B A
20.7
21.8
22.7
23.5
D.6
36'-0"
36'-0"10'-0"26'-0"36'-0"
11'-4"
32'-0"31'-7"
CENTERLINE OF
ROOF PEAK
S L
O P
E
F L
O
F
S L
O P
E
CENTERLINE OF
ROOF PEAK
S L
O P
E
S L
O P
E
F L
O
F
CHASE
AREA NIC
AREA NIC AREA NIC AREA NIC
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
O
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M R
X X
X X
X X
X
X X
X
X X
X
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
F O
A
G G
N
O R
R
O L
I N
A
S O
F
O
P E
R A
T I O
C
I L
I T
Y
S
O T
F
AE101
FLOOR PLAN - NEW WORK
1/8" - 1'-0'
PLAN
NORTH
T
R
U
E
N
O
R
T
H
BUILDING KEY PLAN
PROJECT
LOCATION
NOT TO SCALE
A1
A3
A1 A1
A1
A2
MECHANICAL
OPS OPEN
OFFICE
VESTIBULE
VESTIBULE
A1
SPT OPEN
OFFICE
OFFICE
CONF
OFFICE
CORRIDOR
C O
R R
I D
O R
CORRIDOR
HOC OPEN
OFFICE
C O
R R
I D
O R
CORRIDOR
ELEC
TEL
STAIRS
AE301
AE301
B2
B2
B2
B1
B2
A2
TYP
PROVIDE TYPICAL INFILL
@ WINDOWS PER 10/AE501
(5 LOCATIONS)
A
A
AE401
CHASE
SEE ENLARGED PLAN
FOR WALL TYPES AND
DOOR NUMBERS IN
THIS AREA
A
B
A
SEE DETAILS ON AE504
FOR NEW CMU OPENING
AND HEAD & JAMB
CONDITIONS FOR NEW
FRAME & DOOR
B1
A3
COMM
COMM
CORRIDOR
C O
R R
I D
O R
OFFICE
VESTIBULE
FEMALE
RESTROOM
MALE
RESTROOM
CLASSROOM
CLASSROOM
FOLDING PANEL
PARTITION WALL
(45 STC) & TRACK
SYSTEM
AE101
F L
O O
R
P
L A
N
N
W
W
R
K
T
F
E R
Y
M
B
E N
N E
T T
T
F
E R
Y
K
B
R O
D B
E R
A E
D
G N
INSTALL NEW
FRAMING & GWB
TO MATCH EXIST
A
A
B1
AE402
AE402
B1
C2
C2
C2
B2
B2
C3
C1 C1
B3
B3
B3
B2
B2
B2
A
A
B2
B2
NEW FRAMED OPENING W/ 16 GA,
STEEL, CASED OPENING (3'-0"W x 6'-8"H)
B2
OFFICE
OFFICE
OFFICE
B
B2
B2
A
A
B
B2
A
B
A
A
A
C O
R R
I D
O R
CONF
A
A
B2
B2
AE402
AE402
B2
~1'-8"
AE303
AE302
A
A
A
OPEN OPEN
OPEN
O P
E N
AE503
AE503
NEW WORK NOTES
LOW PROFILE ACCESS FLOOR RAMP AND RAILS,
SEE SHEET AE402 FOR DETAILS
FURR OUT COLUMN, SEE DETAILS ON SHEET AE503
1 1
TYP
LEGEND
REFER ALSO TO LEGEND ON 1-001
SECURE PERIMETER
PARTITION TYPES, SEE SHEET AE701
B2
AE502
TYP
7" MAX
A2
M
A M
E N
D M
E N
T
SOUND BATT INSULATION
AS SCHED.
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
METAL FRAME
DOOR AS SCHED.
2"
WALL TYPE
AS SCHED
SOUND BATT INSULATION
AS SCHED.
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
METAL FRAME
DOOR AS SCHED.
2"
WALL TYPE
AS SCHED
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
METAL FRAME
DOOR AS SCHED.
2"
WALL TYPE
AS SCHED
DOOR AS SCHED.
2"
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
METAL FRAME
WALL TYPE
AS SCHED
NEW VCT OR LVT
FLOOR FINISH AS
SCHED.
DOOR AS SCHED.
EXIST CONC. SLAB
AS OCCURS
NEW FLOOR TILE @
RESTROOMS AS
SCHED.
DOOR AS SCHED.
NEW MARBLE
THRESHOLD AS SCHED.
COORD W/ FLOOR FINISH.
SEE PROFILE DETAIL
NEW VINYL TILE
AS SCHED.
EXIST CONC. SLAB
AS OCCURS
1:2 MAX
SLOPE
1/4"
MAX
2"
NOTE:
EDGES ARE SYMMETRICAL
SOUND BATT
INSULATION AS SCHED.
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
METAL FRAME
DOOR AS SCHED.
WALL TYPE C3
CORRIDOR CLASSROOM
FILL FRAME W/
INSULATION
ACOUSTICAL
SEAL
WALL TYPE
AS SCHED
DOOR AS SCHED.
ROLLER ASSEMBLY
2X FIRE-TREATED
WOOD BLOCKING
EXTRUDED ALUMINUM
WRAP FRAME
EXTRUDED
ALUMINUM VALANCE
BUILT-UP HEADER W/
(2) STUDS AND
(2) STUD TRACKS
EXTRUDED ALUMINUM
WRAP FRAME
DOUBLE 16 GA
JAMB STUDS
WALL TYPE
AS SCHED
CONCEALED
SILL GUIDE
ACOUSTIC
BOTTOM SEAL
NEW FLOOR FINISH
AS SCHED.
DOOR AS SCHED.
EXIST CONC. SLAB
AS OCCURS
CAULK PERIMETER
OF FRAME
EACH SIDE
METAL FRAME
2"
WALL TYPE
AS SCHED
ALUMINUM FRAME
WALL TYPE
AS SCHED
CAULK PERIMETER
OF FRAME
EACH SIDE
2"
NEW ALUM. THRESHOLD
W/ ACCESSIBLE EDGE SET IN
BEADS OF ACOUSTICAL
SEALANT
DOOR AS SCHED.
1 3/4"1 1/2"1 3/4"
1/ 4"
1/ 4"
SURFACE MOUNTED
AUTOMATIC DOOR BOTTOM
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
O
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M R
X X
X X
X X
X
X X
X
X X
X
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
F O
A
G G
N
O R
R
O L
I N
A
S O
F
O
P E
R A
T I O
C
I L
I T
Y
S
O T
F
AE502
D O
E
N I N
G
D
E T
A I L
S
R
B
L A
I R
M
B
E N
N E
T T
T
F
E R
Y
K
B
R O
D B
E R
A E
D
G N
AE502
DOOR HEAD DETAIL
3" = 1'-0'
AE502
DOOR JAMB DETAIL
3" = 1'-0'
AE502
DOOR HEAD DETAIL
3" = 1'-0'
AE502
DOOR JAMB DETAIL
3" = 1'-0'
AE502
DOOR THRESHOLD DETAIL
3" = 1'-0'
AE502
DOOR THRESHOLD DETAIL
3" = 1'-0'
AE502
PROFILE DETAIL
6" = 1'-0'
MARBLE THRESHOLD
AE502
DOOR JAMB DETAIL (HEAD SIM)
3" = 1'-0'
AE502
BARN DOOR HEAD DETAIL
3" = 1'-0'
AE502
BARN DOOR JAMB DETAIL
3" = 1'-0'
AE502
BARN DOOR SILL DETAIL
3" = 1'-0'
AE502
CASED OPENING JAMB DETAILS (HEAD SIM)
3" = 1'-0'
STEEL FRAME ALUMINUM FRAME
AE502
DOOR THRESHOLD DETAIL
3" = 1'-0'
M
A M
E N
D M
E N
T
3'-4"
CUT JOINT OUT FOR
6" ANGLE BEARING
A-A
5'-8"
8" CMU WALL
AS OCCURS
NEW OPENING; CUT AFTER
ANGLE IS INSTALLED
GROUT ADJACENT
CELLS SOLID
NEW CUSTOM-WIDTH, 2-PIECE
DOOR FRAME, W/O RABBETS
7'-2"
BOT ANGLE
GROUT ADJACENT
CELLS SOLID
3/8" SLEEVE
ANCHORS
@ 8" C/C EA. SIDE
W/ 4" EMBED
3 1/2" x 3 1/2" x 3/8"
LOOSE LAID W/ 6"
BEARING EA. SIDE
SECTION A-A
CONTRACTOR SHALL VERIFY
WALL ASSEMBLIES PRIOR TO
SAWCUTTING CMU JOINTS
NEW 12 GA, CUSTOM-WIDTH
HEAD AND JAMB @ BOTH WALL
ASSEMBLIES. CONTRACTOR TO
VERIFY ACTUAL THROAT WIDTH
FILL VOIDS W/ SOUND BATTS
UP TO 24" ABOVE OPENING
NEW EXPANSION JOINT
COVER @ HEAD & JAMBS
1'-1 1/4" VERIFY
1 1/4" 1'-8" VERIFY
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
NEW WALL TYPE AS
SCHEDULED
SHIM @ NEW STUD WALL
ASSEMBLY AS REQ'D
STEEL PLATE SHIMS @ STEEL
ANGLES SECURED TO BACK SIDE
OF STEEL HEADS AND JAMBS. DO
NOT INTERFERE W/ SECUREMENT
FOR EXPANSION JOINT COVERS
NEW DOOR AS SCHED
6 3/4"
SECURE NEW DOOR FRAME
TO NEW STEEL JAMB AS
REQ'D
FILL CELLS W/ GROUT PER
DETAIL 1/AE504
ANGLES AND ANCHORS PER
DETAIL 1/AE504
STEEL PLATE SHIMS @
STEEL ANGLES SECURED
TO BACK SIDE OF STEEL
HEADS AND JAMBS. DO NOT
INTERFERE W/
SECUREMENT FOR
EXPANSION JOINT COVERS
NEW EXPANSION JOINT
COVER @ HEAD & JAMBS
FILL VOIDS W/ SOUND BATTS
24" BEYOND EDGE OF
OPENING
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
NEW WALL TYPE AS
SCHEDULED
SHIM @ NEW STUD WALL
ASSEMBLY AS REQ'D
NEW EXPANSION JOINT
THRESHOLD @ FLOOR
FROM SAME MFR OF HEAD
& JAMB TO MATCH
SECURE NEW DOOR FRAME
TO NEW STEEL JAMB AS
REQ'D
NEW DOOR AS SCHED
6 3/4"
NEW EXPANSION JOINT
THRESHOLD @ FLOOR
FROM SAME MFR OF HEAD
& JAMB TO MATCH
EXIST SLAB &
STRUCTURE AS
OCCURS TO REMAIN
INTACT
NEW WALL TYPE AS
SCHEDULED
FASTENER PER MFR
RECOMMENDATIONS
EXIST SLAB &
STRUCTURE AS
OCCURS TO REMAIN
INTACT
NEW DOOR & FRAME AS
SCHED
NEW WALL TYPE AS
SCHEDULED
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
EXIST CMU AS
OCCURS
EXIST LEDGER
AS OCCURS
NEW THRESHOLD AS SCHED
SECURE NEW DOOR FRAME
TO EXIST CMU AS REQ'D
NEW WALL TYPE AS
SCHEDULED
NEW DOOR & FRAME AS
SCHED
EXIST CMU AS
OCCURS
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
O
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M R
X X
X X
X X
X
X X
X
X X
X
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
F O
A
G G
N
O R
R
O L
I N
A
S O
F
O
P E
R A
T I O
C
I L
I T
Y
S
O T
F
AE504
CMU OPENING @ NEW PASSAGEWAY LOCATION
1" = 1'-0'
AE504
NEW PASSAGEWAY HEAD DETAIL
3" = 1'-0'
AE504
NEW PASSAGEWAY JAMB DETAIL
3" = 1'-0'
AE504
NEW PASSAGEWAY THRESHOLD DETAIL
3" = 1'-0'
AE504
P A
S S
A G
E W
E
N I N
G
D
E T
A I L
S
T
F
E R
Y
M
B
E N
N E
T T
T
F
E R
Y
K
B
R O
D B
E R
A E
D
G N
AE504
@ EXISTING OPENING
3" = 1'-0'
NEW HEAD DETAIL
AE504
@ EXISTING OPENING
3" = 1'-0'
NEW JAMB DETAIL
M
A M
E N
D M
E N
T
"A"
SINGLE SWING
DOOR
AS SCHED
A S
S C
H E
D
"SB"
SINGLE BARN
DOOR
3'-0"
OPENING WIDTH
6' -1
0" P
A N
E L
H T
"DB"
DOUBLE BARN
DOOR
6'-0"
OPENING WIDTH
6' -1
0" P
A N
E L
H T
MTL1
A S
S C
H E
D 2"
AS SCHED
FIN FLR
MTL2
A S
S C
H E
D 4"
AS SCHED
2"2"
DOOR AND FRAME SCHEDULE
DOOR
NUMBER
DOOR
HARDWARE
SET
FRAME
REMARKSWIDTH HEIGHT TYPE
DOOR
MATERIAL FINISH COATING GLAZING STC RATING TYPE MATERIAL FINISH COATING HEAD JAMB THRESHOLD
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
O
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M R
X X
X X
X X
X
X X
X
X X
X
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
F O
A
G G
N
O R
R
O L
I N
A
S O
F
O
P E
R A
T I O
C
I L
I T
Y
S
O T
F
4003A
4003B
4003C
4004A
4005A
4006A
4007A
4200A
4201A
4202A
4203A
4213A
4213B
4214A
4216A
4216B
4218A
4219A
4220A
4221A
4222A
4222B
4230A
6306A
6312A
6313A
6315A
NOTES
LEGEND
1. SEE INTERIOR FINISH SCHEDULE FOR INTERIOR
DOOR COLORS.
2. SECURE (ICD/ICS 705) PERIMETER DOOR ASSEMBLY
3. EXIT ONLY DOOR WITHOUT EXTERIOR HARDWARE
4. EXIT DEVICE
ACOU ACOUSTIC
AL ALUMINUM
ANOD ANODIZED
ATFP ANTI TERRORISM / FORCE PROTECTION
BP BI-PASS
CO CASED OPENING
(E) EXISTING
FF FACTORY FINISH
FPG FIRE PROTECTIVE GLAZING
GL1 TEMPERED CLEAR
HD HEAVY DUTY
HM HOLLOW METAL
IGU INSULATED GLASS UNIT
LAM LAMINATED
MD MAX DUTY
MFR MANUFACTURER
MG METAL GATE
MTL METAL
NRP NON-REMOVABLE HINGE PINS
ORG ORGANIC
PB PANIC BAR
PT PAINT
SC SOLID CORE WOOD
SMK SMOKE RATED
ST STAIN COLOR
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD DUTY
STL STEEL
SWG SAFETY WIRED GLASS
TEMP TEMPERED
WD WOOD
XHD EXTRA HEAVY DUTY
4003 CORRIDOR
4003 CORRIDOR
4003 VESTIBULE
4004 STAIRS
4005 ELEC
4006 TEL
4007 MECHANICAL
4200 VESTIBULE
4201 MALE RESTROOM
4202 FEMALE RESTROOM
4203 VESTIBULE
4213 OFFICE
4213 OFFICE
4214 CONFERENCE
4215 OFFICE
4216 HOC OPEN OFFICE
4216 HOC OPEN OFFICE
4218 OFFICE
4219 SPT OPEN OFFICE
4220 OFFICE
4221 CLASSROOM
4222 CLASSROOM
4222 CLASSROOM
4230 CORRIDOR
6306A CORRIDOR
6312 CORRIDOR
6313 COMM
6315 CORRDIOR
ROOM
NUMBER ROOM NAME
4'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
3'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
3'-0" 7'-0" (E) MTL FIELD PT-4, PT-5 -- -- -- (E) MTL FIELD PT-4, PT-5 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
4'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
3'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
3'-0" 7'-0" (E) MTL (E) (E) -- -- -- (E) MTL (E) (E) (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT
4'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-3
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 6/AE502 HW-2
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 6/AE502 HW-2
3'-0" 7'-0" A MTL FIELD PT-5 -- 45 -- MTL1 MTL FIELD PT-5 3/AE502 4/AE502 5/AE502 HW-1 SEE NOTES 2, 4
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-5
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-5
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-5
4'-0" 7'-0" DB WD FF FF -- -- -- MFR MFR FF FF 10/AE502 11/AE502 12/AE502 HW-7
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-4
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-4
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-5
3'-0" 7'-0" A MTL FIELD PT-5 -- -- -- MTL1 MTL FIELD PT-5 1/AE502 2/AE502 5/AE502 HW-4
3'-0" 7'-0" SB WD FF FF -- -- -- MFR MFR FF FF 10/AE502 11/AE502 12/AE502 HW-7
3'-0" 7'-0" A MTL FIELD PT-5 -- 45 3/4 HR MTL1 MTL FIELD PT-5 11/AE501 11/AE501 5/AE502 HW-8 SPECIAL ACOUSTICAL DOOR W/ NRP
3'-0" 7'-0" A MTL FIELD PT-5 -- 45 3/4 HR MTL1 MTL FIELD PT-5 8/AE502 8/AE502 5/AE502 HW-9 SPECIAL ACOUSTICAL DOOR W/ NRP, 180° CLOSER
3'-0" 7'-0" A BY MFR FF FF -- 45 -- MFR MFR FF FF MFR MFR -- -- SPECIAL ACOUSTICAL SEAL PER MFR
4'-0" 7'-0" A MTL FIELD PT-4, PT-5 -- 45 -- MTL2 MTL FIELD PT-4, PT-5 5/AE504 6/AE504 13/AE502 HW-10 SEE NOTES 2, 3, 4
4'-0" 7'-0" (E) MTL (E) (E) -- -- -- (E) MTL (E) (E) (E) (E) (E) HW-11
4'-0" 7'-0" A MTL FIELD PT-4, PT-5 -- -- 1 HR MTL1 MTL FIELD PT-4, PT-5 2/AE504 3/AE504 4/AE504 HW-6 MAGNETIC HOLD-OPEN DEVICE
3'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
3'-0" 7'-0" (E) MTL FIELD PT-4 -- -- -- (E) MTL FIELD PT-4 (E) (E) (E) (E) EXIST DOOR & FRAME TO REMAIN INTACT & REFINISHED
AE601
D O
H
E D
U L
E
T Y
P E
S
A
A
M E
S
R
B
L A
I R
M
B
E N
N E
T T
T
F
E R
Y
K
B
R O
D B
E R
A E
D
G N
AE601
FRAME TYPES
1/4" - 1'-0'
AE601
DOOR TYPES
1/4" - 1'-0'
NOTES:
1. CONTRACTOR SHALL COORDINATE DOOR AND FRAME COLORS WITH THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO REFINISHING EXISTING DOORS AND FRAMES, AND THE FINISHING OF NEW DOORS AND FRAMES. THIS PROJECT CONSISTS OF DOORS AND FRAMES TO RECEIVE A DIFFERENT COLOR ON THE INSIDE AND OUTSIDE FACES.
2. REPAIR EXISTING DOORS AND FRAMES OF SCRATCHES, SCUFFS, ABRASIONS, ETC., PRIOR TO REFINISHING. SEE ROOM FINISH SCHEDULE ON SHEET AF601 FOR FURTHER
INFORMATION ON COLOR DESCRIPTIONS.
M
A M
E N
D M
E N
T
G
N E
R A
L
C
O N
S T
R U
C T
I O
N
N
O T
E S
G-004
A. CONTRACTOR SHALL COMPLY WITH CURRENT NORTH CAROLINA DEPARTMENT OF
ENVIRONMENTAL QUALITY (DEQ) EROSION AND SEDIMENT CONTROL PLANNING AND
DESIGN MANUAL AND FORT BRAGG WATER MANAGEMENT BRANCH (WMB) STANDARDS FOR
EROSION CONTROL WORK, IF APPLICABLE.
B. ALL NCDOT STANDARDS REFERENCES WILL BE THE LATEST EDITION. CONTRACTOR MAY
REFER TO HTTPS://CONNECT.NCDOT.GOV, IF APPLICABLE.
C. CONTRACTOR SHALL COMPLY WITH CURRENT UFC, NC BUILDING CODE AND OTHER
APPLICABLE REQUIREMENTS AS INDICATED ON THESE CONTRACT DOCUMENTS.
6. DEMOLITION
A. ALL CONSTRUCTION AFFECTING TRAFFIC SHALL COMPLY WITH THE FORT BRAGG TRAFFIC
CONTROL IDC, MUTCD, AND NCDOT STANDARD DRAWINGS AND SPECIFICATIONS - LATEST
EDITION. AN ALTERNATE EMERGENCY TRAFFIC CONTROL DETOUR MAY BE REQUIRED.
7. TRAFFIC CONTROL
A. UNLESS SPECIFICALLY NOTED TO BE REMOVED, ALL EXISTING BUILDING COMPONENTS
AND OTHER SITE ITEMS SHALL REMAIN INTACT AND BE PROTECTED AGAINST DAMAGE
DURING THE CONSTRUCTION PERIOD.
B. THE CONTRACTOR SHALL EXERCISE CAUTION DURING DEMOLITION OPERATIONS. THE
CONTRACTOR SHALL REPAIR AND RESTORE ALL EXISTING CONSTRUCTION TO REMAIN THAT
IS DAMAGED DURING DEMOLITION OPERATIONS. REPAIRS TO DAMAGED WORK AREAS SHALL
MATCH EXISTING ADJACENT FINISHED SURFACES OR THE CONTRACTOR SHALL REPLACE
DAMAGED CONSTRUCTION WITH NEW WORK.
C. NO KNOWN ASBESTOS EXISTS WITHIN THIS PROJECT AREA. IF CONTRACTOR SUSPECTS
ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE PRESENT HE SHALL NOTIFY THE
CONTRACTING OFFICER'S REPRESENTATION IMMEDIATELY.
5. STANDARDS
8. EXISTING UTILITY INTERRUPTIONS
A. EXISTING UTILITIES MAY BE INTERRUPTED FOR A MAXIMUM OF 12 HOURS AT A TIME.
CONTRACTOR IS REQUIRED TO CONTACT THE COR AND OBTAIN APPROVAL PRIOR TO
ANTICIPATED INTERRUPTION. SEE SPECIFICATIONS FOR PRE-APPROVAL REQUIREMENTS.
B. ALL UTILITY INTERRUPTIONS AND DURATIONS SHALL BE INDICATED ON THE
CONTRACTOR'S SCHEDULE AND COORDINATED WITH THE COR.
C. FIRE ALARM INTERRUPTIONS SHALL BE SCHEDULED IN WRITING WITH THE COR A MINIMUM OF
14 DAYS IN ADVANCE.
9. EXTERIOR UTILITY WORK
A. NO EXTERIOR UTILITY WORK IS ANTICIPATED.
10. SECURITY PROCEDURES FOR ACCESS
2. CONSTRUCTION PHASING & PROJECT SCHEDULES
A. THE CONTRACTOR SHALL ENSURE THAT HIS ACTIVITIES SHALL NOT INTERFERE WITH THE
OPERATIONS CONDUCTED AT SURROUNDING BUILDINGS AND WORK AREAS.
B. CONTRACTOR SHALL NOT BLOCK ACCESS TO EXISTING BUILDINGS, ROADS AND/OR FACILITIES.
C. CONTRACTOR SHALL PROVIDE A CONSTRUCTION PHASING PLAN AND PROJECT SCHEDULE TO
THE COR PRIOR TO CONSTRUCTION AND MOBILIZATION. CONTRACTOR SHALL PROVIDE WEEKLY
UPDATES ON THE PROJECT SCHEDULE FOR FULL DURATION OF PROJECT. THE WEEKLY
UPDATES SHALL BE PROVIDED SHOWING THE SCHEDULE FOR THE UPCOMING 2 WEEKS
INCLUDE UPDATES REGARDING THE PHASING OF CONSTRUCTION.
D. ADJACENT AREAS WILL BE OCCUPIED BY GOVERNMENT PERSONNEL THROUGHOUT THE
CONSTRUCTION PERIOD. CONTRACTOR SHALL NOT ALLOW CONSTRUCTION ACTIVITIES TO
DISRUPT ON-GOING GOVERNMENT OPERATIONS DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR STAGING AREA
A. SEE EROSION CONTROL PLAN. (NOT APPLICABLE).
A. CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND THE STAGING AREA. THE
TYPE, MATERIAL, HEIGHT, AND LOCATION OF THE FENCE SHALL BE IN ACCORDANCE WITH
SPECIFICATIONS AND APPROVED BY THE GOVERNMENT PRIOR TO INSTALLATION.
B. ALL WORK ACTIVITIES AND STORAGE SHALL BE CONFINED WITHIN THE ESTABLISHED
PROJECT LIMITS UNLESS SPECIFICALLY AUTHORIZED BY THE COR FOR SPECIFIED PERIODS
OF TIME.
C. THE CONTRACTOR MUST HAVE AT LEAST ONE EMPLOYEE ONSITE TO RECEIVE AND DIRECT
PLACEMENT OF DELIVERED MATERIALS AND SUPPLIES.
1. CONSTRUCTION METHODS AND PROCEDURES & CONTRACTOR ACCESS
A. THE WORK FOR THIS PROJECT CONSISTS OF FURNISHING ALL LABOR, EQUIPMENT,
TRANSPORTATION, AND MATERIALS NECESSARY TO PERFORM ALL WORK IN STRICT
ACCORDANCE WITH THE PROJECT SPECIFICATIONS, APPLICABLE DIRECTORATE OF PUBLIC
WORKS (DPW) DRAWINGS, UNIFIED FACILITIES CRITERIA (UFC), SECURITY OPERATIONS
TRAINING FACILITY (SOTF) STANDARDS, FORT BRAGG INSTALLATION DESIGN GUIDELINES (IDG)
AND OTHER CONTRACT DOCUMENTS. THE SCOPE OF WORK OF THIS CONTRACT IS
REFERENCED IN PROJECT SPECIFICATIONS SECTION 01 00 05.
B. THE CONTRACTOR SHALL REFER TO THE PROJECT SPECIFICATIONS IN ALL SITUATIONS. THE
CONTRACTOR SHALL BRING CONFLICTS BETWEEN PROJECT SPECIFICATIONS AND PLANS TO
THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE (COR) FOR RESOLUTION. ALL
MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE PROJECT SPECIFICATIONS.
C. ALL DIMENSIONS AND CONDITIONS TIED TO OR OTHERWISE RELATED TO EXISTING
CONSTRUCTION ARE SUBJECT TO FIELD VERIFICATION BY THE CONTRACTOR. VERIFICATION
SHALL BE MADE PRIOR TO ORDERING, FABRICATING, OR CONSTRUCTING ANY RELATED
STRUCTURAL COMPONENTS. WHERE DISCREPANCIES OCCUR, THE CONTRACTOR SHALL ADVISE
THE COR IMMEDIATELY AND PROVIDE THE COR WITH THE CORRECT DIMENSIONS AND
CONDITIONS.
D. THE CONTRACTOR SHALL PROVIDE ONSITE SANITARY FACILITIES FOR HIS WORKERS DURING
THE ENTIRE CONSTRUCTION PHASE. COORDINATE LOCATION WITH COR.
E. THE CONTRACTOR SHALL ADEQUATELY PROTECT ALL EXISTING SITE FEATURES AND FACILITIES
DURING DEMOLITION AND CONSTRUCTION.
F. PRIOR TO ANY DEMOLITION OR NEW WORK COMMENCING THE CONTRACTOR SHALL ARRANGE A
MEETING WITH THE COR AND SOTF REPRESENTATIVE TO DISCUSS ALL ELECTRICAL OUTAGE
PROCEDURES FOR SHUTDOWN OF ANY ELECTRICAL PANELS. THE ELECTRICAL CONTRACTOR
MUST NOTIFY THE COR, IN WRITING, AT LEAST 7 DAYS PRIOR TO ANY ELECTRICAL SHUTDOWN
DURING DEMOLITION OR NEW CONSTRUCTION.
4. EROSION AND SEDIMENT CONTROL
GENERAL NOTES:
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
O
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M R
X X
X X
X X
X
X X
X
X X
X
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
F O
A
G G
N
O R
R
O L
I N
A
S O
F
O
P E
R A
T I O
C
I L
I T
Y
S
O T
F
G D
G N
R
D
O W
N S
M
B
E N
N E
T T
R
D
O W
N S
R
D
O W
N S
INSTALLATION:
· AIR QUALITY (GENERATORS) - DPW-ECB AIR QUALITY PROGRAM MANAGER
· ARMY RADIATION PERMIT (ARP) - INSTALLATION RADIATION SAFETY OFFICER - VICTOR D. WOOTEN, 910-9088-4138
· BOILERS & GENERATORS PERMIT - DPW-ECB AIR QUALITY - MIKE FISHER, REM
· BORROW PIT PERMIT - DPW - ENVIRONMENTAL BRANCH (SUBMIT 14 CALENDAR DAYS PRIOR TO WORK) -
BORROW PIT HAS BEEN CLOSED BY DPW FOR DISPOSAL UNTIL FURTHER NOTICE.
· CONSTRUCTION AND DEMOLITION (C&D) WASTE PERMIT - FOR FORT BRAGG LAMONT ROAD
CONSTRUCTION AND DEMOLITION LANDFILL FACILITY - DPW - ENVIRONMENTAL BRANCH. LANDFILL HAS
REACHED ITS CAPACITY TO ACCEPT CONSTRUCTION AND DEMOLITION WASTE AND WILL NO LONGER
ACCEPT CONSTRUCTION AND DEMOLITION WASTE (TO INCLUDE FRIABLE ASBESTOS CONTAINING
MATERIALS). SEE DPW'S SOLID WASTE AND RECYCLING REQUIREMENTS, DATED 6 OCT 2016, OR
CONTACT JEFF SLOOP AT JEFFERY.W.SLOOP.CTR@MAIL.MIL OR FAX TO (910)396-4188, ATTN: SOLID
WASTE OFFICE.
· DIGGING/EXCAVATION PERMIT (FB FORM 1605-E) - DPW - FACILITIES ENGINEER (SUBMIT 15 CALENDAR
DAYS PRIOR TO WORK)
· ENVIRONMENTAL PERMITS (POSSIBLE 180 DAY PROCESS). SEE SPEC SECTION 01 57 19.
·· REGULATORY PERMITS
·· CLEAN AIR ACT (CAA) [FEDERAL, STATE AND LOCAL] - DPW - INSTALLATION ENVIRONMENTAL
OFFICE (AIR PROGRAM MANAGER)
·· GENERAL USE PERMITTED EQUIPMENT (SEE FAR 52.236-7.)
·· STREAM CROSSING PERMIT (SEE CLEAN WATER ACT SECTION 404 AND SECTION 401 WATER
QUALITY).
·· TITLE V AIR PERMITS (BASED ON TYPE OF MATERIAL DUST, BOILERS AND DOMESTIC WATER
HEATERS) - DPW - ENVIRONMENTAL BRANCH, ENVIRONMENTAL COMPLIANCE BRANCH (ECB)
·· TRANSPORTER AND DISPOSAL FACILITIES PERMITS
·· EXCAVATION
· IRRIGATION PERMIT - DPW WATER QUALITY PROGRAM MANAGER, KRISTIN COX, 910-908-3969 /
KRISTIN.M.COX2.CIV@MAIL.MIL.
· CHENEGA GLOBAL SERVICES, LLC, STORAGE TANKS AND WATER QUALITY PROGRAM, FORT
BRAGG-DPW-ECB, HENRY HAAS AT 910-432-8450 / HENRY.E.HAAS.CTR@MAIL.MIL.
· LANDFILL DISPOSAL PERMIT - DPW-ENVIRONMENTAL SUSTAINMENT DIVISION (ESD), 910-396-3372.
· PHOTOGRAPHY - INSTALLATION PERMIT - DIRECTOR OPERATIONS DIRECTORATE DCS G3/5/7 - POC IS
MR. DREDDRICK BROWN, DSN 225-8469 OR COM (703) 695-8469.
· TRAFFIC CONTROL PERMIT - DPW TRANSPORTATION ENGINEER, RAY GOFF, 910-907-1759
· UTILITY CONNECTION
· UTILITY OUTAGE REQUESTS - FT BRAGG DPW
COUNTY
· WATER WELL
FEDERAL
· NOTICE OF PROPOSED CONSTRUCTION OR ALTERATION - FAA FORM 7460-1
NC STATE:
· ASBESTOS REMOVAL FOR DEMOLITION/RENOVATION - NCPH, RALEIGH (10 WORKING DAYS PRIOR TO
REMOVAL)
· AIR QUALITY
· DEMOLITION
· EROSION & SEDIMENT CONTROL (E&SC) CERTIFICATE OF APPROVAL/PERMIT - DEQ (FORMALLY
NCDENR) DEPT OF WATER QUALITY (DWQ), UNDER GENERAL PERMIT NO. NCG010000 FOR
"CONSTRUCTION ACTIVITIES THAT ARE ALSO SUBJECT TO THE NORTH CAROLINA SEDIMENTATION
POLLUTION CONTROL ACT OF 1973."
· GENERAL STORMWATER DISCHARGE
· GEOTHERMAL (POSSIBLE COUNTY INVOLVEMENT)
· SEPTIC SYSTEM (POSSIBLE COUNTY INVOLVEMENT)
· STORMWATER MANAGEMENT - NCDEQ AND FT BRAGG WATER MANAGEMENT BRANCH
· WATER SYSTEM SERVICE (FIRE PROTECTION AND DOMESTIC WATER SERVICE) - NCDEQ.
ASUS (AMERICAN STATES UTILITY SERVICES) :
· WATER AND SANITARY SEWER
COE SAFETY:
· CONFINED SPACE ENTRY PERMIT - (SEE EM 385-1-1, DATED 30 NOV 2014, SECTION 34 (STARTING ON
PAGE 34-1)
· ENERGIZED WORK PERMIT - MUST BE SUBMITTED TO THE COR IN ADVANCE FOR ACCEPTANCE. (SEE
EM 385-1-1, DATED 30 NOV 14, PARAGRAPH 11.A.02C).
· HOT WORK PERMIT - DEFINED AS HOT RIVETING, WELDING, BURNING, ABRASIVE BLASTING, OR OTHER
FIRE- OR SPARK-PRODUCING OPERATIONS. (SEE EM 385-1-1, DATED 30 NOV 2014, PARA 09.A.04 (PAGE
9-1 & 2) & PAGE Q-29. THE FORT BRAGG FIRE DEPARTMENT REQUIRES NOTICE 14 CALENDAR DAYS
PRIOR TO WORK, FOR:
·· WELDING
·· CUTTING
·· HEATING
D. PERMITS, AS LISTED ABOVE, ARE NOT INTENDED TO BE A COMPLETE LIST. CONTRACTORS ARE TO
ADD ADDITIONAL PERMITS, AS THEY BECOME KNOWN. KINDLY REPORT SUCH INFORMATION TO THE
POINT OF CONTACT (BELOW). PERMIT SUBMITTALS ARE TO BE SUBMITTED TO THE GOVERNMENT FOR
REVIEW AND APPROVAL. AVOID OMISSIONS.
A. CONTRACTOR SHALL SECURE ALL PERMITS NECESSARY FOR CONSTRUCTION OF THE PROJECT.
DETERMINE FEE BASIS AS APPROPRIATE AND PAY ALL FILING FEES AT NO ADDITIONAL COST TO THE
GOVERNMENT. CONSTRUCTION SHALL NOT BEGIN ON ANY PHASE WITHOUT APPROPRIATE PERMITS.
B. PERMITS ARE TO BE MAINTAINED BY THE CONTRACTOR ONSITE, ORGANIZED IN A 3 RING BINDER, TABBED AND WITH A TABLE OF CONTENTS FOR INSPECTION BY THE GOVERNMENT.
C. THE FOLLOWING PERMITS MAY BE REQUIRED FOR PROJECTS AT FORT BRAGG.
11. PERMITS
A. CONTRACTOR SHALL FOLLOW SOTF SECURITY REQUIREMENTS AT ALL TIMES.
REFER TO SPECIFICATION SECTION 01 00 60 FOR ADDITIONAL INFORMATION.
B. CONTRACTOR SHALL FOLLOW SOTF SECURITY POLICIES ON-SITE AT ALL TIMES. IN GENERAL, THE
CONTRACTOR WILL BE GIVEN FULL ACCESS TO THE PROJECT SITE AS SHOWN ON THE PLANS,
HOWEVER, PERIODS MAY BE ENCOUNTERED WHEN NO CONTRACTOR OR SUBCONTRACTOR
PERSONNEL WILL BE ALLOWED ON THE CONSTRUCTION SITE. WORK STOPPAGES DUE TO THESE
EVENTS WILL BE HELD TO AN ABSOLUTE MINIMUM, AND THE CONTRACTOR WILL BE GIVEN AS
MUCH ADVANCED NOTICE AS POSSIBLE. THE GOVERNMENT RESERVES THE RIGHT TO INSTRUCT
THE CONTRACTOR TO EVACUATE THE SITE WITHOUT PRIOR NOTIFICATION AT ANY TIME AND MAY
REFUSE ENTRY OF ANY OR ALL CONTRACTOR PERSONNEL. NOTICE OF THE WORK STOPPAGE AND
RESUMPTION WILL BE RELAYED THROUGH THE COR WHO WILL COMMUNICATE THIS INFORMATION
TO THE CONTRACTOR. IT IS NOT POSSIBLE TO ESTIMATE THE NUMBER OR LENGTH OF SUCH
WORK STOPPAGES. GOVERNMENT-CAUSED DELAYS WILL RESULT IN DAY-FOR-DAY EXTENSION OF
THE CONTRACT COMPLETION DATE. ON A CASE-BY-CASE BASIS, DEPENDING UPON THE IMPACT
TO THE PROJECT CRITICAL-PATH, DELAYS MAY BE CONSIDERED COMPENSABLE.
C. THE CONTRACTOR'S PERSONNEL MUST WEAR IDENTIFICATION IN ACCORDANCE WITH
SOTF SECURITY POLICIES AT ALL TIMES.
D. ACCESS TO THE PROJECT AREA IS LIMITED TO NORMAL WORK HOURS (0730 TO 1600)
UNLESS SPECIFICALLY APPROVED BY THE COR FOR SPECIFIED PERIODS OF TIME OUTSIDE THE
NORMAL WORK HOURS. EXCLUDES FEDERAL HOLIDAYS.
E. IT IS A CRIME UNDER 18 USC 795 TO PHOTOGRAPH DEFENSE INSTALLATIONS WITHOUT
FIRST OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY
INSTALLATION. IT IS ALSO A CRIME UNDER 18 USC 797 TO REPRODUCE, PUBLISH SELL OR GIVE
AWAY ANY PHOTOGRAPH, PICTURE OR GRAPHIC REPRESENTATION OF A DEFENSE INSTALLATION
WITHOUT FIRST OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY
INSTALLATION AND SOTF.
F. DESIGNATE THE INSTALLATION AS A RESTRICTED AREA. RESTRICTED AREA POSTING RESTRICTS
PERSONS GAINING ACCESS TO MILITARY INSTALLATION FROM CONDUCTING IMAGERY
SURVEILLANCE, PHOTOGRAPHY AND VIDEO RECORDING WITHOUT THE INSTALLATION
COMMANDERS AND SOTF CONSENT.
G. THE INTRODUCTION OF WEAPONS, AMMUNITION, EXPLOSIVES OR OTHER PROHIBITED ITEMS AND
PHOTOGRAPHY OF THE FACILITIES IS PROHIBITED WITHOUT SPECIFIC AUTHORIZATION FROM THE
SOTF COMMANDER.
M
A M
E N
D M
E N
T