TPlans_W912P519B0008.pdf

PDF 7 MB Posted

Attached to
Dale Hollow Cable Tray Replacement
Solicitation number
W912P519B0008
Issued by

About this file

Technical Plans W912P519B0008

View the file

Other files

File Type Posted
W912P519B0008_Bid_Abstract.pdf PDF
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_31.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_38.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_15.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_42.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_25.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_13.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_20.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_03.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_26.jpg JPG image
W912P519B000_Amedn3_Appendix_C_Revised_Plans__Page_1.pdf PDF
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_44.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_40.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_09.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_37.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_21.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_18.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_06.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_12.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_34.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_27.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_24.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_17.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_07.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_43.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_02.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_14.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_33.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_05.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_39.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_28.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_11.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_08.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_29.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_36.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_35.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_16.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_32.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_10.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_23.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_41.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_19.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_04.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_30.jpg JPG image
W912P519B0008_Amend3_Appendix_C_Revised_TSpecs_Page_22.jpg JPG image
W912P519B0008_Amend3_Revised_TSpecs.pdf PDF
19B0008_USACE_Site_Visit_SignIn.pdf PDF
19B0008_Vendors_SiteVisit_SignIn.pdf PDF
W912P519B00080003.pdf PDF
W912P519B00080002.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REFERENCE O

NLY

Revised equipment in Telephone Rm.

Revised cable ducts in Telephone Rm.

Rev.swbd.outline to include Livingston line pnl.

8-26-47

3-19-46

1-21-48

REC. APPR.DATE DESCRIPTION

2 3 4

B Q-3/831

WAR DEPARTMENT

2 x 1/4 GROUND BUS H

POWER CABLES

POWER AND CONTROL CABLE TUNNEL

TJ

18" CABLE TRAYS

D

D

C Q-3/831

H

5" SLEEVES CEMENT ASBESTOS

ON FIBRE, AND BELLS BOTH

* C.C TELEPHONE

AUTOCALL RELAY BACK *R

E

L A

Y

R A

C K

P .A .B .X

S W

IT

C H

B O

A R

D TELEPHONE ROOM

(CONDUIT ARRANGEMENT)

Q-3/8304

LOAD CONRTROL RECEIVER

DISTRIBUTING FRAME

TELEMETER TRANSMITTER

M.G. SET

CONTROL

M O

T O

R

G E

N E

R A

T

S

T

C

P A

S S

A G

E W

A Y

L

ENDS-SEE NOTE #1

CROSS TRAY IN

MIDDLE TIER

C

T R

A Y

S

B

T R

A Y

S

A U

X

IL

IA

Y

N T

R

L

W

IT

C H

B O

A R

D

FLOOR EL 536.0

V

N

T

IL

A T

IO

N

N T

R

P

N

V H

SPLICE PLATES

SEE NOTE #3

CROSS TRAY IN

MIDDLE TIER

AS

A

T R

A Y

S

P QP Q

C

NOTE:

ALL CABLE TRAYS IN SPREAD ROOM

ARE 12" WIDE

1A 1 2 2A 3 4 5 6

MB

CHECKERED PLATE WALKWAY EL.545.75

BENCHBOARD

N

EL.546.17

RR45 & 46-1 1/4 I

1 2

10 SPA @ 3"CTS.

RR42-1I

B

N

T

MS

F U

T

T R

A Y

S

F U

T

T R

A Y

S

H

T R

A Y

S

F

T R

A Y

S

F

T R

A Y

S

G

T R

A Y

S

INSTRUMENT

PANELS

E

T R

A Y

S

E

T R

A Y

S

D

T R

A Y

S

D

T R

A Y

S

CABLE RACK

5" THICK WALL FIBRE

OR TRANSITE CONDUIT

J

LFKE LFKER R

RELAY

PANELS

M MG G

11A 2 2A 3 4 5 6

CROSS TRAYS IN LOWER TIER ONLY

T

2 3

CORPS OF ENGINEERS, U.S. ARMY

A S

A S

M S

M S

T

U

U

A S

B

B

TRAY 13

B

B

G

B

B

P R

TRAY 12

SECTION J-J

IP

T

G

S

D

S

IB

IB

IB

IB

IB

D

S

B

B

B

B

G S

B

B

B

B

A

B

B

B

B

N

T

T

B

B

SECTION H-H

TRAY 9

TRAY 8

TRAY 3

TRAY 2

M S

M S

M S

M S

M S

P

T

IP

T

IB

IB

CABLES RELOCATED FROM TRAY F3

CABLE RELOCATED FROM TRAY E3

F3F’3

SECTION K-K

ID

S

G

S

B

B

G

S

D

S

IB

F2F’2

G

M S

P R

U

U

B

B

B

F3F’1

CABLES RELOCATED FROM TRAY F2

M S

TRAY F1

A S

A S

T

N

SECTION N-N

B

N

T

L1M S

A S

B

M S

R R

L2

U

B

U

SECTION L-L SECTION P-P

G

B

B

D3D’3 G

G

C3A S

T

A S

A S

D2D’2 A

A S

A S

C2A

A

A

A

D1D’1 C1

M S

M S

U

U

G

R R

B

A S

A

U

A S

A S

B

U

M S

M S

B

M S

M S

A

A

G

SECTION M-M SECTION Q-Q

D3D’3 M S

M S

B3

D2D’2 G

B2A S

A S

A S

A S

A S

D1D’1 B1

M S

M S

M S

M S

A S

G

R R

A

A S

U

A S

B

U

B

A Q-3/831

SECTION R-R

H3

H1

B

B

D

S

B

B

D S

M S A

P

T

B

G S

B

IN

I

P

T

B

B

G S

M S A

A S

CABLE

RELOCATED FROM

TRAY F’3

CABLES

RELOCATED FROM

G TRAYS

PLAN AT EL.516.17

SECTION F-F

E3E’3

E2E’2

E1E’1

IB

IB

B

B

A

SECTION E-E

G3

G2

G1

P

T

B

B

G S

D S

CABLES RELOCATED FROM F TRAYS

SECTION G-G

G3

G2

G1

B

G S

D S

P

T

D

S

B

M S

M S

M S

CABLES RELOCATED FROM TRAY F3

U

U

M S

G

G

G

G

A

A S

A S

SECTION T-T

B

U

G

U

A

A S

U S

U

S T

G

A S

A S

U

U

M S

G

G

G

G

A

A S

A S

SECTION D-D

B

U

G

A

G

U S

A

A S

U

G

U

M S

U S

M S

M S

M S

A

A S

M S

M S

A

A

A S

A S

U

A

A

A

A

A Q-3/831

TRAY13

TRAY12

TRAY 9

TRAY 8

TRAY 7

TRAY 2

Revised as constructed1-10-52

Revised as constructed4-9-56

Added cable MS1105-1-74

CUMBERLAND RIVER WATERSHED

OBEY RIVER, TENNESSEE

POWERHOUSE

EL.536.0

SPREAD ROOM-GENERAL ARRANGEMENT

IN SHEETS SHEET NO.

12" 0 1’ 2’ 3’

SCALE: 1/2"=1’-0"

U.S. ENGINEER OFFICE, NASHVILLE, TENN.,

SUBMITTED. APPROVED RECOMMENDED: APPROVED:

CHAS. T. MAIN. INC. PRINCIPAL ENGINEER COL.CORPS OF ENGINEERS

DISTRICT ENGINEER

SUPV.

DRAWN

TO ACCOMPANY SPECIFICATION

DATED Q-3/830.6

4’

CHECKED

TRACED

RD

EA FEB. 1946

RECORD DRAWING AS CONSTRUCTED

6" 5’ xx cmn

U.P.R XXX

xx

BY

J.E.P.

cmn

CHKD.

G.S.G

WS HWS

P.M.J XX

REVISIONS

GENERAL NOTES:

AFTER CABLES HAVE BEEN INSTALLED. SEAL BOTH ENDS OF

CONDUITS WITH WELL TAMPED OAKUM. PLUG OR CAP ENDS

OF ALL UNUSED CONDUITS.

CABLE TRAY JOINTS SHALL OCCUR ON CENTER LINE OF

SUPPORTING ANGLE.

SPLICE PLATES MADE FROM 3/8" ASBESTOS LUMBER, FASTENED

WITH 3/8" FLAT HEAD MACHINE SCREWS, COUNTER SUNK, 4"C.C

BOLT CABLE TRAYS TO SUPPORTS WITH 2-1/4" CARRIAGE

BOLTS AT EACH SUPPORT.

FURNISHED BY GOVERNMENT. MOUNTING AND WIRING BY

POWER HOUSE CONTRACTOR.

CABLE TRAYS ARE JOHNS-MANSVILLE TRANSITE AND SHALL BE

INSTALLED ACCORDING TO SPECIFICATIONS.

CABLES EXTENDING 3FT. OR MORE BETWEEN TRAY AND CONDUIT

SHALL BE SUPPORTED AS SHOWN IN DETAIL A Q-3/842 B

FOR MISCELLANEOUS STEEL DETAIL SEE DWG. Q-3/840

SECTIONS SHOWN, COVER INSTALLATION OF THIRD UNIT CABLES.

ONLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

CABLES RELOCATED FROM

4’-9"

1 4

23’-3"

6’-3"

" 2

1 2

1 2

1 2 " 9"9"

4’-6"6’-3"

9"

4’-6"1’-0"

9"

60°

3’-3"

5’-0"5’-3"1’-4"5’-0"6"

3" 3"

3"

1’-7"

3"

3"

4"

5"

4"

3"

3"

3"

3"

4’-4"4’-0"3’-9"

2"

2’-10

3’-9" 3’-1

3’-8"4’-4"4’-4"

4’-4" 4’-4" 4’-4" 3’-8" 3’-0" 3’-4" 3’-0"

1’-5"1’-7"

1’-0" 1’-0" 3’-8" 2’-2" 1’-0" 3’-6" 1’-0" 1’-5" 2’-8" 1’-0" 2’-10"8’-9"

7’-4" 7’-4" 8"

7’-1 " 7’-1

" 1’-5

" 9’-4

4’-0" 1’-8" 2’-0" 4"

2’-8" 1’-8" 3’-0" 5"

1’-8" 3’-0" 6’-9" 2’-0" 10" 2’-0"

3’-9"

17’-0"

1’-6"2’-6"

9’-0"6’-1"2’-0"2’-6"

1’-0" 4’-4"9"

1 2

1 2

1’-6"

2’-2" 2’-2"

2’-5"2’-5"8"

AS19-1 1/4UP

DAM CONDUITS

END HERE

DALE HOLLOW RESERVOIR PROJECT

A

A S

U

U

G

2"x1/8"grd.bus

2x2x3/16"L

See note No.2

Desk

EI.550

EI.546.17

For plan at this level see

Dwg. Q-3/830

EI.536

EI.532.87

2"x1/8"copper bars runing the whole length of tunnel fibre

EI.536

E

SECTION B-B

Cable duct 1’-2"x1’-7"– made of 1/2" transite on angle iron frame

2"x1/4"copper ground bus

Gov. motor

1-1/4" conduit for telephone cable.see dwg. Q-3/812

500,000 C.M. bare cable to ground bus in tunnel

1,000,000 C.M.bare copper grd.

wire to ground test station

No.4 in dam.see specifications par2-01(d)(4)

Insulator cablesupport on 4’-0"cts.

500,000 C.M rubber insulated cable,thru tunnel to No.1 test station at switchyard

4"x1/4" copper bar

Up to penthouse

D

EI.550

Cabinet "V.H" size showm on wiring diagram dwg. q-3/837

EI.536

SECTION A-A

SECTION C-C

GENERAL NOTES:

1. Ground all iron racks,tray hangaers,and steel switchboard panels to ground bus.

2. Cable risers shall be neatly fastened to cable supports by cable clips or cleats screwed to the maple strips

3. sections A-A,B-B AND C-C taken from dwg. Q-3/830

4. For miscellaneous steel details in spread room see dwg. Q-3/840

SUPV.

DRAWN

U.S. ENGINEER OFFICE, NASHVILLE, TENN.,

IN SHEETS

Revised equipment in telephone

Revised cable ducts in ’telephone Rm.

8-28-47

3-19-46

DATE

1-21-48

DESCRIPTION

REVISIONS

EA

BY CHKD.

c.m.n

E.A c.m.n

APPR.REC.

Q-3/831.5

COL.CORPS OF ENGINEERS

TO ACCOMPANY SPECIFICATION

PRINCIPAL ENGINEER

APPROVED RECOMMENDED:

SCALE: 1/2 INCH = 1 FOOT

SPREAD ROOM-SECTIONS

POWERHOUSE

OBEY RIVER,TENNESSEE

DALE HOLLOW RESERVOIR PROJECT

CUMBERLAND RIVER WATERSHED

CHAS.T.MAIN,INC.

CHECKED

TRACED

SUBMITTED.

DATED

012" 5’ 3" 4"

DISTRICT ENGINEER

APPROVED:

SHEET NO.6" 1" 5"

FEB 1946

RECORD DRAWING AS CONSTRUCTED

room;added gov. motor contactors

Added 2 trays for Livingston line

12-19-51 Revised as constructed

3-1-56 Revised as constructed

P.M.J EA

W.V.h a.f.g

W.S.Jr. S.B.F

CORPS OF ENGINEERS,U.S.ARMY

WAR DEPARTMENT

E A

F

IL

R P ,C

O S

M

S A ,C

A H

A N

G

F

H

EUGEME DIETZGEN CO.

13’-5" 8’-3"

2’-7"

8’-6"

2’-11"1’-5

3’-2�"

6"

10"

6"

4"

"3’-1

"8’-5"

3’-7"

4"

1’-2"

’7

1’9"

" 2 ’5

3’-0"

2’-0"

1’-3"

11"

7"9"

3’-0"

4"

EI.533.5

Raceway

4"x9"

EI.545.5

Ground test station No.2

(door removed)

4"x1/4" copper bar 8"Water pipe EI.531.25

1 208/115 VTransf.

Type TDI-40

1I Disc. 5w.

100 Amp.

Fused~Sq.D

*A-41353

Gen.#1 Gen. #2sta. serv

T u n n e l

Box3’-0"high by 5’-6" long by 1’-2" deep to clear water pipe.Made of 1/2" transite with angle iron frame.front cover to be removanle.

18" Trays

1-1/2" Conduit

Fibre

2"x5" slot at 60°

Fireproof

Door

EI.538.0

Ground test sta.No.2

2"x5" slot at 60°

2-2" conduits, 2"x1/4" bare copper bus

Between ground bus on both sides of tunnel.

#4/10 grd.cable

18"Trays

Elev.532.0 to bottom

Elev.5325 to bottom

3X2-1/2X1/4"L

P.B

Load Control receiver

Motor generator set control

B e n c h b o a r d

Auxiliarycontrol switchboard

In s t r u m e n t

P a n e ls

R e la y

P a n e ls

Autocall Relay Rack

C.C.Telephone

Gov. motor contactor box

EI.545.75

Ground bus

3"I

3"li

1x3/16" iron bar see note No.2

5/8" Expansion bolt

#4/0 grd. cable contactor Box

1�"x3" maple strip

Cover Sheet
Contract Drawings
Q-3^842E
Q-3^842F
Reference Drawings
q-3^203.1
q-3^296.1
q-3^297.3
q-3^830.6
q-3^831.5
q-3^842b.7
q-3^842c.7
2019-04-18T07:51:45-0500
STEELE.LOUIS.A.1536319952

File details come from the government source that posted it.