TPlans_W912P519B0008.pdf
PDF 7 MB Posted
- Attached to
- Dale Hollow Cable Tray Replacement
- Solicitation number
- W912P519B0008
About this file
Technical Plans W912P519B0008
View the file
Other files
Show 40 more
Latest 50 of 55 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REFERENCE O
NLY
Revised equipment in Telephone Rm.
Revised cable ducts in Telephone Rm.
Rev.swbd.outline to include Livingston line pnl.
8-26-47
3-19-46
1-21-48
REC. APPR.DATE DESCRIPTION
2 3 4
B Q-3/831
WAR DEPARTMENT
2 x 1/4 GROUND BUS H
POWER CABLES
POWER AND CONTROL CABLE TUNNEL
TJ
18" CABLE TRAYS
D
D
C Q-3/831
H
5" SLEEVES CEMENT ASBESTOS
ON FIBRE, AND BELLS BOTH
* C.C TELEPHONE
AUTOCALL RELAY BACK *R
E
L A
Y
R A
C K
P .A .B .X
S W
IT
C H
B O
A R
D TELEPHONE ROOM
(CONDUIT ARRANGEMENT)
Q-3/8304
LOAD CONRTROL RECEIVER
DISTRIBUTING FRAME
TELEMETER TRANSMITTER
M.G. SET
CONTROL
M O
T O
R
G E
N E
R A
T
S
T
C
P A
S S
A G
E W
A Y
L
ENDS-SEE NOTE #1
CROSS TRAY IN
MIDDLE TIER
C
T R
A Y
S
B
T R
A Y
S
A U
X
IL
IA
Y
N T
R
L
W
IT
C H
B O
A R
D
FLOOR EL 536.0
V
N
T
IL
A T
IO
N
N T
R
P
N
V H
SPLICE PLATES
SEE NOTE #3
CROSS TRAY IN
MIDDLE TIER
AS
A
T R
A Y
S
P QP Q
C
NOTE:
ALL CABLE TRAYS IN SPREAD ROOM
ARE 12" WIDE
1A 1 2 2A 3 4 5 6
MB
CHECKERED PLATE WALKWAY EL.545.75
BENCHBOARD
N
EL.546.17
RR45 & 46-1 1/4 I
1 2
10 SPA @ 3"CTS.
RR42-1I
B
N
T
MS
F U
T
T R
A Y
S
F U
T
T R
A Y
S
H
T R
A Y
S
F
T R
A Y
S
F
T R
A Y
S
G
T R
A Y
S
INSTRUMENT
PANELS
E
T R
A Y
S
E
T R
A Y
S
D
T R
A Y
S
D
T R
A Y
S
CABLE RACK
5" THICK WALL FIBRE
OR TRANSITE CONDUIT
J
LFKE LFKER R
RELAY
PANELS
M MG G
11A 2 2A 3 4 5 6
CROSS TRAYS IN LOWER TIER ONLY
T
2 3
CORPS OF ENGINEERS, U.S. ARMY
A S
A S
M S
M S
T
U
U
A S
B
B
TRAY 13
B
B
G
B
B
P R
TRAY 12
SECTION J-J
IP
T
G
S
D
S
IB
IB
IB
IB
IB
D
S
B
B
B
B
G S
B
B
B
B
A
B
B
B
B
N
T
T
B
B
SECTION H-H
TRAY 9
TRAY 8
TRAY 3
TRAY 2
M S
M S
M S
M S
M S
P
T
IP
T
IB
IB
CABLES RELOCATED FROM TRAY F3
CABLE RELOCATED FROM TRAY E3
F3F’3
SECTION K-K
ID
S
G
S
B
B
G
S
D
S
IB
F2F’2
G
M S
P R
U
U
B
B
B
F3F’1
CABLES RELOCATED FROM TRAY F2
M S
TRAY F1
A S
A S
T
N
SECTION N-N
B
N
T
L1M S
A S
B
M S
R R
L2
U
B
U
SECTION L-L SECTION P-P
G
B
B
D3D’3 G
G
C3A S
T
A S
A S
D2D’2 A
A S
A S
C2A
A
A
A
D1D’1 C1
M S
M S
U
U
G
R R
B
A S
A
U
A S
A S
B
U
M S
M S
B
M S
M S
A
A
G
SECTION M-M SECTION Q-Q
D3D’3 M S
M S
B3
D2D’2 G
B2A S
A S
A S
A S
A S
D1D’1 B1
M S
M S
M S
M S
A S
G
R R
A
A S
U
A S
B
U
B
A Q-3/831
SECTION R-R
H3
H1
B
B
D
S
B
B
D S
M S A
P
T
B
G S
B
IN
I
P
T
B
B
G S
M S A
A S
CABLE
RELOCATED FROM
TRAY F’3
CABLES
RELOCATED FROM
G TRAYS
PLAN AT EL.516.17
SECTION F-F
E3E’3
E2E’2
E1E’1
IB
IB
B
B
A
SECTION E-E
G3
G2
G1
P
T
B
B
G S
D S
CABLES RELOCATED FROM F TRAYS
SECTION G-G
G3
G2
G1
B
G S
D S
P
T
D
S
B
M S
M S
M S
CABLES RELOCATED FROM TRAY F3
U
U
M S
G
G
G
G
A
A S
A S
SECTION T-T
B
U
G
U
A
A S
U S
U
S T
G
A S
A S
U
U
M S
G
G
G
G
A
A S
A S
SECTION D-D
B
U
G
A
G
U S
A
A S
U
G
U
M S
U S
M S
M S
M S
A
A S
M S
M S
A
A
A S
A S
U
A
A
A
A
A Q-3/831
TRAY13
TRAY12
TRAY 9
TRAY 8
TRAY 7
TRAY 2
Revised as constructed1-10-52
Revised as constructed4-9-56
Added cable MS1105-1-74
CUMBERLAND RIVER WATERSHED
OBEY RIVER, TENNESSEE
POWERHOUSE
EL.536.0
SPREAD ROOM-GENERAL ARRANGEMENT
IN SHEETS SHEET NO.
12" 0 1’ 2’ 3’
SCALE: 1/2"=1’-0"
U.S. ENGINEER OFFICE, NASHVILLE, TENN.,
SUBMITTED. APPROVED RECOMMENDED: APPROVED:
CHAS. T. MAIN. INC. PRINCIPAL ENGINEER COL.CORPS OF ENGINEERS
DISTRICT ENGINEER
SUPV.
DRAWN
TO ACCOMPANY SPECIFICATION
DATED Q-3/830.6
4’
CHECKED
TRACED
RD
EA FEB. 1946
RECORD DRAWING AS CONSTRUCTED
6" 5’ xx cmn
U.P.R XXX
xx
BY
J.E.P.
cmn
CHKD.
G.S.G
WS HWS
P.M.J XX
REVISIONS
GENERAL NOTES:
AFTER CABLES HAVE BEEN INSTALLED. SEAL BOTH ENDS OF
CONDUITS WITH WELL TAMPED OAKUM. PLUG OR CAP ENDS
OF ALL UNUSED CONDUITS.
CABLE TRAY JOINTS SHALL OCCUR ON CENTER LINE OF
SUPPORTING ANGLE.
SPLICE PLATES MADE FROM 3/8" ASBESTOS LUMBER, FASTENED
WITH 3/8" FLAT HEAD MACHINE SCREWS, COUNTER SUNK, 4"C.C
BOLT CABLE TRAYS TO SUPPORTS WITH 2-1/4" CARRIAGE
BOLTS AT EACH SUPPORT.
FURNISHED BY GOVERNMENT. MOUNTING AND WIRING BY
POWER HOUSE CONTRACTOR.
CABLE TRAYS ARE JOHNS-MANSVILLE TRANSITE AND SHALL BE
INSTALLED ACCORDING TO SPECIFICATIONS.
CABLES EXTENDING 3FT. OR MORE BETWEEN TRAY AND CONDUIT
SHALL BE SUPPORTED AS SHOWN IN DETAIL A Q-3/842 B
FOR MISCELLANEOUS STEEL DETAIL SEE DWG. Q-3/840
SECTIONS SHOWN, COVER INSTALLATION OF THIRD UNIT CABLES.
ONLY.
1.
2.
3.
4.
5.
6.
7.
8.
9.
CABLES RELOCATED FROM
4’-9"
1 4
23’-3"
6’-3"
" 2
1 2
1 2
1 2 " 9"9"
4’-6"6’-3"
9"
4’-6"1’-0"
9"
60°
3’-3"
5’-0"5’-3"1’-4"5’-0"6"
3" 3"
3"
1’-7"
3"
3"
4"
5"
4"
3"
3"
3"
3"
4’-4"4’-0"3’-9"
2"
2’-10
3’-9" 3’-1
3’-8"4’-4"4’-4"
4’-4" 4’-4" 4’-4" 3’-8" 3’-0" 3’-4" 3’-0"
1’-5"1’-7"
1’-0" 1’-0" 3’-8" 2’-2" 1’-0" 3’-6" 1’-0" 1’-5" 2’-8" 1’-0" 2’-10"8’-9"
7’-4" 7’-4" 8"
7’-1 " 7’-1
" 1’-5
" 9’-4
4’-0" 1’-8" 2’-0" 4"
2’-8" 1’-8" 3’-0" 5"
1’-8" 3’-0" 6’-9" 2’-0" 10" 2’-0"
3’-9"
17’-0"
1’-6"2’-6"
9’-0"6’-1"2’-0"2’-6"
1’-0" 4’-4"9"
1 2
1 2
1’-6"
2’-2" 2’-2"
2’-5"2’-5"8"
AS19-1 1/4UP
DAM CONDUITS
END HERE
DALE HOLLOW RESERVOIR PROJECT
A
A S
U
U
G
2"x1/8"grd.bus
2x2x3/16"L
See note No.2
Desk
EI.550
EI.546.17
For plan at this level see
Dwg. Q-3/830
EI.536
EI.532.87
2"x1/8"copper bars runing the whole length of tunnel fibre
EI.536
E
SECTION B-B
Cable duct 1’-2"x1’-7"– made of 1/2" transite on angle iron frame
2"x1/4"copper ground bus
Gov. motor
1-1/4" conduit for telephone cable.see dwg. Q-3/812
500,000 C.M. bare cable to ground bus in tunnel
1,000,000 C.M.bare copper grd.
wire to ground test station
No.4 in dam.see specifications par2-01(d)(4)
Insulator cablesupport on 4’-0"cts.
500,000 C.M rubber insulated cable,thru tunnel to No.1 test station at switchyard
4"x1/4" copper bar
Up to penthouse
D
EI.550
Cabinet "V.H" size showm on wiring diagram dwg. q-3/837
EI.536
SECTION A-A
SECTION C-C
GENERAL NOTES:
1. Ground all iron racks,tray hangaers,and steel switchboard panels to ground bus.
2. Cable risers shall be neatly fastened to cable supports by cable clips or cleats screwed to the maple strips
3. sections A-A,B-B AND C-C taken from dwg. Q-3/830
4. For miscellaneous steel details in spread room see dwg. Q-3/840
SUPV.
DRAWN
U.S. ENGINEER OFFICE, NASHVILLE, TENN.,
IN SHEETS
Revised equipment in telephone
Revised cable ducts in ’telephone Rm.
8-28-47
3-19-46
DATE
1-21-48
DESCRIPTION
REVISIONS
EA
BY CHKD.
c.m.n
E.A c.m.n
APPR.REC.
Q-3/831.5
COL.CORPS OF ENGINEERS
TO ACCOMPANY SPECIFICATION
PRINCIPAL ENGINEER
APPROVED RECOMMENDED:
SCALE: 1/2 INCH = 1 FOOT
SPREAD ROOM-SECTIONS
POWERHOUSE
OBEY RIVER,TENNESSEE
DALE HOLLOW RESERVOIR PROJECT
CUMBERLAND RIVER WATERSHED
CHAS.T.MAIN,INC.
CHECKED
TRACED
SUBMITTED.
DATED
012" 5’ 3" 4"
DISTRICT ENGINEER
APPROVED:
SHEET NO.6" 1" 5"
FEB 1946
RECORD DRAWING AS CONSTRUCTED
room;added gov. motor contactors
Added 2 trays for Livingston line
12-19-51 Revised as constructed
3-1-56 Revised as constructed
P.M.J EA
W.V.h a.f.g
W.S.Jr. S.B.F
CORPS OF ENGINEERS,U.S.ARMY
WAR DEPARTMENT
E A
F
IL
R P ,C
O S
M
S A ,C
A H
A N
G
F
H
EUGEME DIETZGEN CO.
13’-5" 8’-3"
2’-7"
8’-6"
2’-11"1’-5
3’-2�"
6"
10"
6"
4"
"3’-1
"8’-5"
3’-7"
4"
1’-2"
’7
1’9"
" 2 ’5
3’-0"
2’-0"
1’-3"
11"
7"9"
3’-0"
4"
EI.533.5
Raceway
4"x9"
EI.545.5
Ground test station No.2
(door removed)
4"x1/4" copper bar 8"Water pipe EI.531.25
1 208/115 VTransf.
Type TDI-40
1I Disc. 5w.
100 Amp.
Fused~Sq.D
*A-41353
Gen.#1 Gen. #2sta. serv
T u n n e l
Box3’-0"high by 5’-6" long by 1’-2" deep to clear water pipe.Made of 1/2" transite with angle iron frame.front cover to be removanle.
18" Trays
1-1/2" Conduit
Fibre
2"x5" slot at 60°
Fireproof
Door
EI.538.0
Ground test sta.No.2
2"x5" slot at 60°
2-2" conduits, 2"x1/4" bare copper bus
Between ground bus on both sides of tunnel.
#4/10 grd.cable
18"Trays
Elev.532.0 to bottom
Elev.5325 to bottom
3X2-1/2X1/4"L
P.B
Load Control receiver
Motor generator set control
B e n c h b o a r d
Auxiliarycontrol switchboard
In s t r u m e n t
P a n e ls
R e la y
P a n e ls
Autocall Relay Rack
C.C.Telephone
Gov. motor contactor box
EI.545.75
Ground bus
3"I
3"li
1x3/16" iron bar see note No.2
5/8" Expansion bolt
#4/0 grd. cable contactor Box
1�"x3" maple strip
| Cover Sheet |
| Contract Drawings |
| Q-3^842E |
| Q-3^842F |
| Reference Drawings |
| q-3^203.1 |
| q-3^296.1 |
| q-3^297.3 |
| q-3^830.6 |
| q-3^831.5 |
| q-3^842b.7 |
| q-3^842c.7 |
| 2019-04-18T07:51:45-0500 | |
| STEELE.LOUIS.A.1536319952 |
File details come from the government source that posted it.