Electrical_Plans_-_Renovate_bldg_1201_(2015).pdf
PDF 2 MB Posted
- Attached to
- LIGHTNING PROTECTION Federal contract opportunity
- Solicitation number
- W912JA-17-T-0032
About this file
Bldg 1201 Renovate 2015
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Lightning_Protection_SOW_-_Rev2.docx | DOCX document | |
| Aircraft_Shelter_-_electrical_panel_2.JPG | JPG image | |
| Electrical_Plans_-_1403.pdf | ||
| Electrical_Plans_-_Construct_Bldg_1203.pdf | ||
| Site_Visit_Roster.pdf | ||
| Electrical_Plans_-_Renovate_bldg_1201_(2011).pdf | ||
| Aircraft_Shelter_-_electrical_panel_1.JPG | JPG image | |
| Site_Visit_Lightning_protection.pdf | ||
| Pre-bid_site_visit_-_QA_1.docx | DOCX document | |
| Lightning_Protection_SOW_-_Rev1.doc.docx | DOCX document | |
| 13100_-_LIGHTING_PROTECTION.doc | DOC document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E1.1
E1.1
E1.1
E1.1
EXISTING PANEL 'LP1A'
EXISTING PANEL 'L14'
EXISTING PANEL 'LIG1'EXISTING
TRANSFORMER T-'LIG1'
EXISTING PANEL 'RS480'
EXISTING PANEL 'RS208'
EXISTING PANEL 'MECH1'
EXISTING PANEL 'MDP'
EXISTING PANEL 'LP1B'
EXISTING SWITCHBOARD 'SE'
EXISTING TRANSFORMER
'T-LIG1A'
EXISTING PANEL 'LIG1A'
EXISTING PANEL 'L15'
1 2
3 4
1 2
3 4
1 2
3 4
1 2
3 4EXISTING PANEL 'LP22'
EXISTING PANEL 'PP2'
EXISTING PANEL 'LP23'
EXISTING PANEL '2-3'
EXISTING PANEL 'MECH2'
EXISTING PANEL 'LP2A'
EXISTING PANEL 'LIGA2'
EXISTING
TRANSFORMER 'T-LIGA2'
EXISTING PANEL 'LP2'
EXISTING
TRANSFORMER T-'LIG2'
EXISTING PANEL 'LIG2'
EXISTING PANEL 'L24'
E1.1 6
E1.1
E1.1
E1.1
1 2
3 4
1 2
3 4
1 2
3 4
1 2
3 4
EXISTING PANEL 'LP25'
E0.1
SCALE: 1/16"=1'-0"
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
GARNER
C O N S U L T I N G E N G I N E E R S PROJECT NO: 14-069
E0.1
SCALE: 1/16"=1'-0"
KEYED NOTES:
1. DISCONNECT ALL LIGHT FIXTURES, EMERGENCY LIGHT UNITS AND EXIT SIGNS IN
STAIRWELL (HATCHED AREA) AND MAKE EXISTING LIGHTING BRANCH CIRCUIT
WIRING SAFE FOR RE-USE. PROVIDE BLANK JUNCTION BOX COVER PLATES AS
REQUIRED.
2. CONTRACTOR SHALL IDENTIFY PANELBOARD AND CIRCUIT NUMBER SERVING
EXISTING LIGHTS AND EXIT SIGNS PRIOR TO REMOVAL AND MARK THE COVER PLATE
OF THE HOMERUN JUNCTION BOX WITH THIS INFORMATION.
3. EXISTING RECEPTACLES AND OTHER WALL MOUNTED ELECTRICAL DEVICES SHALL
BE MAINTAINED AND PROTECTED DURING CONSTRUCTION.
4. EXISTING FIRE ALARM SYSTEM SHALL BE MAINTAINED AND PROTECTED DURING
CONSTRUCTION. REMOVE EXISTING COMBINATION SMOKE/HEAT DETECTOR, STORE
AND PROTECT DEVICES FOR RE-USE AS SHOWN ON DRAWING E1.1.
5. REPLACE EXISTING RECEPTACLE WITH NEW 20A, GFI RECEPTACLE TO SUPPORT
WATER COOLER.
6. PROVIDE NEW 20A, GFI RECEPTACLE IN EXISTING JUNCTION BOX FOR CONNECTION
TO NEW WATER COOLER. PROVIDE 2#12 & 1#12(G) IN EXISTING CONDUIT BACK TO
PANELBOARD '2-3' AND CONNECT TO EXISTING CIRCUIT BREAKER 18 LABELED 'REC
WATER COOLER'.
7. EXISTING EXIT SIGN AND FLEXIBLE METALLIC CABLING TO BE REMOVED. PROVIDE
PLUG IN JUNCTION BOX AS REQUIRED.
# GENERAL NOTES FOR DEMOLITION:
1. ALL ELECTRICAL WORK AND MATERIAL SHALL CONFORM TO THE LATEST EDITION
OF THE N.E.C. AND THE REQUIREMENTS OF THE STATE AND LOCAL AUTHORITY
HAVING JURISDICTION.
2. WHERE ANY CIRCUITS HAVE BEEN INTERRUPTED DUE TO REMOVAL OF OUTLETS,
DEVICES, WALLS, ETC., THE CONTRACTOR SHALL BE RESPONSIBLE FOR
RECONNECTING OR REWIRING THE CIRCUIT AS REQUIRED TO INSURE CIRCUIT CONTINUITY
TO ALL REMAINING AND NEW DEVICES OR FIXTURES.
3. CONTRACTOR SHALL PROVIDE ALL MATERIAL NECESSARY TO FINALIZE A NEAT,
COMPLETE AND PROPERLY WORKING ELECTRICAL SYSTEM WHICH CONFORMS TO
ALL LOCAL CODES AND THE NATIONAL ELECTRICAL CODE AS PER PLANS, AND
SPECS.
4. ALL REMOVED ELECTRICAL EQUIPMENT (i.e. WIRE, CONDUIT, FIXTURES, SWITCHES, ETC.) SHALL BE PROPERLY DISPOSED OF BY THE CONTRACTOR.
5. AFTER COMPLETION OF RENOVATION WORK CONTRACTOR SHALL PROVIDE AND
INSTALL A CORRECT, TYPED DIRECTORY CARD FOR MODIFIED PANELS.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND
BECOME THOROUGHLY FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO BID
DATE, AS HE SHALL BE RESPONSIBLE FOR SAME.
7. ELECTRICAL CONTRACTOR VERIFY STATUS OF ANY ITEMS NOT SHOWN WITH
OWNER PRIOR TO REMOVAL OF ITEM.
8. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING LOADS
ON EXISTING PANELS PRIOR TO ADDING NEW LOADS.
9. ANY BREAKERS ADDED TO EXISTING PANELS SHALL HAVE THE SAME AIC RATING
AS EXISTING.
10. WHERE EXISTING CONDUIT IS INDICATED TO REMOVED IT SHALL BE PERMISSIBLE
TO ABANDON SAID CONDUIT AND REMOVE CONDUCTORS ONLY.
11. ABANDONED AND REMOVED CONDUIT SHALL HAVE WIRE PULLED FROM THEM.
12. PROVIDE AND INSTALL BLANK COVERS ON ALL REMAINING OUTLETS OR JUNCTION
BOXES WHERE DEVICES OR FIXTURES HAVE BEEN REMOVED.
F1
X
F1
OC
F
EX
F
RL
EX
EX
6 PP
LV
F1
F1
OC
RL
LEX
PP
LV
X
F1
F1
OC
OC
F
EX
F
RL
EX
EX5
WA
PP
LV
LV
F1
F1
OC
RL
L EX
PP
LV
X
F1
F1
OC
F
EX
F
RL
EX
X
EX
PP
LV
F1
F1
OC
RL
3 4
L
EX
PP
LV
X
F1
F1
OC
OC
F EX
F
RL
EX
EX
EX
EX
4WA
PP
LV
LV
F1
F1
OC
RL
L
EX
EX
PP
LV
E1.1
SCALE: 1/4"=1'-0"
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
GARNER
C O N S U L T I N G E N G I N E E R S PROJECT NO: 14-069
E1.1
E1.1
SCALE: 1/4"=1'-0"
E1.1
E1.1
SCALE: 1/4"=1'-0"
E1.1
SCALE: 1/4"=1'-0"
E1.1
E1.1
SCALE: 1/4"=1'-0"
SCALE: 1/4"=1'-0"
SCALE: 1/4"=1'-0"
SCALE: 1/4"=1'-0"
KEYED NOTES:
1. CONTRACTOR SHALL MAKE CONNECTION TO EXISTING CIRCUIT
IN SPACE AS REQUIRED.
2. CONTRACTOR SHALL CONNECT POWER TO LIGHT FIXTURE
CIRCUIT AS SHOWN IN DETAIL 2 ON SHEET E2.1 SUCH THAT
ACTIVATION OF ANY SENSOR WILL CAUSE THE STAIRWELL
LIGHTS TO COME UP TO 100% BRIGHTNESS. STAIRWELL LIGHTS
SHALL NEVER DROP BELOW 50% ILLUMINATION.
3. CONTRACTOR SHALL RE-INSTALL EXISTING COMBINATION
SMOKE/HEAT DETECTOR (REMOVED AND STORED UNDER
DEMOLITION WORK) IN NEW LAY-IN CEILING AND EXTEND
EXISTING FIRE ALARM CIRCUIT AS REQUIRED. EXISTING FIRE
ALARM SYSTEM SHALL BE RE-TESTED AND RE-CERTIFIED IN
AREAS WHERE WORK WAS PERFORMED/COMPLETED.
4. EXISTING FIRE ALARM DEVICE TO BE MAINTAINED AND
PROTECTED DURING CONSTRUCTION.
5. EXISTING ELECTRIC HEATER TO BE MAINTAINED AND
PROTECTED DURING CONSTRUCTION.
6. EXISTING RECEPTACLE TO BE MAINTAINED AND PROTECTED
DURING CONSTRUCTION.
7. RELOCATE EXISTING MC CABLES ABOVE NEW CEILING AND
PATCH HOLES AS REQUIRED TO MAINTAIN FIRE RATING OF
WALL.
8. EXISTING 'BRIEFING IN PROGRESS' SIGN TO BE MAINTAINED AND
PROTECTED DURING CONSTRUCTION.
9. RE-USE EXISTING JUNCTION BOX FOR MOUNTING OF FIXTURE.
EXISTING MANUEL TRANSFER
SWITCH TO BE REMOVED. INSTALL
NEW MANUEL TRANSFER SWITCH
IN SAME LOCATION. REUSE EXISTING
FEEDER CONDUIT. REFER TO RISER
DIAGRAM FOR ADDITIONAL INFORMATION.
REFER TO RISER DIAGRAM
FOR ELECTRICAL WORK
REQUIRED.
GENERATOR PAD
SEE DETAIL FOR
REQUIREMENTS.
GP
REFER TO RISER DIAGRAM
FOR MORE INFORMATION.
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
GARNER
C O N S U L T I N G E N G I N E E R S PROJECT NO: 14-069
FIRST FLOOR PLAN - POWER
SCALE: 3/32"=1'-0"
E2.1
'L24'
'LIG2'
5 5
3 1
'LP2'
L26-1,3,5
SEE NOTE #1 UNDER
ELECTRICAL RENOVATION
NOTES
L26-2
SEE NOTE #1 UNDER
ELECTRICAL RENOVATION
NOTES
L26-4,6,8
SEE NOTE #1 UNDER
ELECTRICAL RENOVATION
NOTES
1. DISCONNECT EXISTING CIRCUIT FROM PANEL 'L24' AND EXTEND EXISTING CIRCUIT AND
RECONNECT TO NEW BREAKERS IN PANEL 'L26' AS INDICATGED BY CIRCUIT NUMBERS.
NEW PANEL 'L26'
NEW PANEL 'EM'
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
GARNER
C O N S U L T I N G E N G I N E E R S PROJECT NO: 14-069
SECOND FLOOR PLAN - POWER
SCALE: 3/32" = 1'-0"
E2.2
SEE NOTE #3 UNDER
ELECTRICAL RENOVATION
NOTES.
RPMC-20/1P
SEE NOTE #2 UNDER
ELECTRICAL RENOVATION
NOTES.
SEE NOTE #1 UNDER
ELECTRICAL RENOVATION
NOTES.
L26-7 L26-9
1. DISCONNECT EXISTING CIRCUIT FROM 20/1P BREAKER AND EXTEND EXISTING
CONDUCTORS TO NEW BREAKER IN PANEL 'L26'.
2. PROVIDE A 20/1P, 120V, CIRCUIT FROM SPARE BREAKER IN EXISTING PANEL 'RPMC'
TO SERVE EXISTING LIGHTS.
3. DISCONNECT EXISTING LIGHTING CIRCUIT FROM PANEL 'LP2'. EXISTING BREAKER SHALL
BECOME SPARE AND REMOVE CONDUCTORS FROM EXISTING CONDUIT. CONDUIT SHALL
REMAIN IN PLACE.
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
GARNER
C O N S U L T I N G E N G I N E E R S PROJECT NO: 14-069
SECOND FLOOR PLAN - LIGHTING
SCALE: 3/32"=1'-0"
E3.1
T-IG2
PANEL
"LIG2"
WITH A PHASE METER PRIOR TO CONNECTING LOADS.
LOADING . CONTRACTOR SHALL TEST EACH FEEDER AND EQUIPMENT FEEDERS
OF ALL POWER FEEDER CONDUCTORS FOR THE PROPER PHASE SEQUENCE AND
2. CONTRACTOR IS RESPONSIBLE FOR THE CONNECTING, INSTALLATION, AND MARKING
1. INSTALLATION AND CONNECTION OF ALL DEVICES SHALL BE IN ACCORDANCE WITH
NEC, MANUFACTURER'S RECOMMENDATIONS, AND STATE AND LOCAL CODES.
PROJECT PRIOR TO BID. CONTRACTOR SHALL THEN PROVIDE THE PROPERLY SIZED OVERCURRENT
3. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND VERIFYING WITH ALL DIVISIONS
THE ACTUAL NAMEPLATE DATA OF ALL EQUIPMENT AND DEVICES SUPPLIED ON THIS
DEVICES (CIRCUIT BREAKERS, CONDUCTORS, DISCONNECTS, FUSES, ETC.) TO PROPERLY PROTECT
THE EQUIPMENT PER THE NEC. ENGINEER'S DESIGN BASED ON DATA GIVEN TO HIM BY
DESIGNERS OF OTHER DIVISIONS, ACTUAL NAMEPLATE DATA COULD DIFFER.
BEEN INSTALLED.
4. SEAL ALL CONDUITS FROM THE EXTERIOR WITH A SEALING COMPOUND, ONCE ALL CABLING HAS
0/3
4# 3/0
1#
6( G)
- E
XI
ST
IN
G 2"
C
4 #3/0 & 1 #6(G) - EXISTING 2"C
SP
AR
E
EXIST.
EXIST.
EXIST.
200/3/1
PANEL
"L26"
NEW
PANEL
"EM"
NEW
4 #3/0 & 1 #6(G) - 2"C
4# 3/0
1#
8( G)
1 1
/4" C
NEW MANUEL TRANSFER SWITCH 'MTS'
200 AMP, 3 POLE, SN, NEMA 3R
FUSED AT 200 AMPS. MOUNTED IN SAME
LOCATION WHERE EXISTING TRANSFER
SWITCH HAS BEEN REMOVED. REUSE
EXISTING FEEDER CONDUIT.
INSTALL NEW 200 AMP, 3 POLE
BREAKER. EXISTING SWITCHBOARD
IS 2500 AMP MAIN CIRCUIT
BREAKER, 120/208V, 3 POLE, 4W.
PANEL
"RPMC"
SEE POWER PLAN FOR LOCATIONS OF PANELS.
DISCONNECT FEEDER FROM BREAKER AND REMOVE CONDUCTORS TO DISCONNECT SWITCH.
DISCONNECT SWITCH SHALL REMAIN. EXISTING BREAKER SHALL BECOME A SPARE.
DISCONNECT CONDUCTORS AND REMOVE EXISTING 100/3 P BREAKER.
EXISTING 2" CONDUIT TO REMAIN AND BE REUSED. REMOVED CONDUCTORS AND REROUTE CONDUIT
AS REQUIRED.
REMOVE EXISTING CONDUCTORS FROM TRANSFER SWITCH LOCATION TO PANEL. EXISTING CONDUIT
SHALL BE ABANDON AND LEFT IN PLACE.
EXISTING MANUAL TRANSFER SWITCH SHALL BE REMOVED.
EXISTING PANEL 'RPMC' SHALL REMAIN IN PLACE. SEE RISER BELOW FOR NEW FEEDER SERVICE.
EXISTING PANEL 'LIG2', TRANSFORMER AND DISCONNECT SWITCH SHALL REMAIN IN PLACE. SEE RISER
PLAN BELOW FOR NEW FEEDER SERVICE.
4 #3 & 1 #8(G) - 1 1/4"C
3#1/0 & 1#6(G) - 2"C
DEMOLITION POWER RISER DIAGRAM
NOT TO SCALE
E4.1
REVISED POWER RISER DIAGRAM
NOT TO SCALE
E4.1
POWER RISER DIAGRAM NOTES: SHEET NOTES:
CONNECT TO EXISTING
DISCONNECT SWITCH
AS REQUIRED.
CONNECT TO EXISTING
PANEL AS REQUIRED.
X
X
X
GP
CONTRACTOR TO PROVIDE 200A PLUG,
EQUAL TO HUBBELL #HBL5200PSIWR WITH
25' OF TYPE W CORD, 5W, 3/0 CONNECTED
TO IT. THE OWNER WILL BE RESPONSIBLE
FOR MAKING FINAL CONNECTION TO
OWNER FURNISHED GENERATOR.
CONTRACTOR TO PROVIDE 200A RECEPTACLE,
EQUAL TO HUBBELL #HBL5200RSIWR MOUNTED
IN BOX EQUAL TO HUBBELL #MB2004W AT
LEAST 18"A.F.G.
4 #3/0 & 1 #6(G) - 2"C
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
GARNER
C O N S U L T I N G E N G I N E E R S PROJECT NO: 14-069
P A N E L B O A R D S C H E D U L E PANEL 'L26'
DIRECTORY LOAD (VOLT*AMPS) CKT
NO
BRKR
AMPS
BRKR
AMPS
CKT
NO
LOAD (VOLT*AMPS) DIRECTORY
A B C A B C
RECEPTS. 600 1 20 20 2 400 RECEPTS.
RECEPTS. 800 3 20 20 4 400 RECEPTS.
RECEPTS. 800 5 20 20 6 600 RECEPTS.
LIGHTS 1120 7 20 20 8 400 RECEPTS.
LIGHTS 1540 9 20 10
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
SUB-TOTAL 1720 2340 800 800 400 600 SUB-TOTAL
VOLTAGE : 120/208, 3PH, 4W PANEL TYPE: AQ TOTAL VA - A 2520 LOCATION
MAIN BREAKER : MLO MAIN BUS: 125A TOTAL VA - B 2740 ELEC. ROOM
MOUNTING: SURFACE A.I.C. RATING: 10K TOTAL VA - C 1400 TOTAL CONNECTED LOAD
NOTES: ENCLOSURE: NEMA 1 TOTAL VA 6660 18.50 A
PANELBOARD SCHEDULE NOTES (APPLYS TO ALL PANELS)
1. PANELBOARD DESIGNATIONS INDICATED IN ABOVE SCHEDULE ARE THOSE OF G.E COMPANY EQUAL EQUIPMENT BY OTHER MANUFACTURERS WILL BE CONSIDERED IF OTHER MANUFACTURER'S PANELS ARE TO BE USED, CONTRACTOR
SHALL BE RESPONSIBLE FOR VERIFYING ALL SPACE REQUIREMENTS.
2. EACH PANELBOARD SHALL HAVE AN INTEGRATED EQUIPMENT RATING EQUAL TO THE LOWEST A.I.C. OF ANY CIRCUIT
BREAKER IN PANEL.
3. WHERE CURRENT LIMITING CIRCUIT BREAKERS ARE USED. THEY SHALL BE SERIES RATED FOR DOWNSTREAM PROTECTION. SUBMITTAL DATA SHALL INCLUDE A CURRENT U.L. APPROVED TABLE OF SERIES CONNECTED RATINGS OF
ALL CIRCUIT BREAKERS TO BE USED.
4. ALL BRANCH CIRCUIT BREAKERS SHALL BE BOLT ON TYPE.
5. ALL CIRCUIT BREAKERS 100A AND ABOVE SHALL BE SOLID STATE.
6. ALL 120/208V, 3PH, 4W PANELS SHALL BE SERIES RATED UNLESS NOTED OTHERWISE.
7. CONTRACTOR TO PROVIDE ALL BRANCH CIRCUIT NUMBERS USING PERMANENT CIRCUIT MARKERS WITH THE PROPER CIRCUIT NUMBER ATTACHED NEXT TO EACH BREAKER. STICK ON NUMBERS WILL NOT BE APPROVED. ON SPECTRA BRANCH BREAKERS, CONTRACTOR TO PROVIDE FIELD MOUNTED PHENOLIC NAMEPLATE INDICATING EACH LOAD.
8. PANEL SHALL HAVE SURGE PROTECTION DEVICE. SURGE PROTECTION DEVICE MUST BE INSTALLED INTERNALLY TO THE ELECTRICAL DISTRIBUTION EQUIPMENT AND SHIPPED FROM THE MANUFACTURER'S FACTORY AS A COMPLETE U.L. LISTED ASSEMBLY. PANELBOARD SPDS SHALL BE GENERAL ELECTRIC TMENVNE/100/200. OR EQUAL. VOLTAGES FOR DEVICES SHALL BE INDICATED ON THE PANELBOARD SCHEDULES AND SINGLE LINE DIAGRAM. THIS NOTE ONLY APPLIES TO PANELS
NOTED SO
9. ALL BLANK SPACES SHALL BE ASSUMED BUSSED SPACE FOR EACH PANELBOARD.
10. A.I.C. RATING, SR STANDS FOR SERIES RATED.
6'-0"
9"
3" 3"
8'-0"
1" BEVEL (TYPICAL)
1" CHAMFER (TYPICAL)
KEYED NOTES:
1. CONCRETE PAD. CONCRETE TO DEVELOP 3000 PSI COMPRESSIVE STRENGTH WITHIN 28 DAYS.
2. COMPACTED GRAVEL FILL. PAD SHOULD BE POURED AGAINST A 3 INCH MINIMUM COMPACTED
GRAVEL FILL THAT IS PLACED ON WELL COMPACTED EARTH.
3. #6 REBAR (GRADE 60) EQUALLY SPACED 12" EACH WAY.
4. #2/0 STRANDED BARE COPPER, CONTINUOUS GROUND BUS WIRE TO BE FURNISHED AND
INSTALLED BY CONTRACTOR.
TYPICAL GENERATOR PAD DETAIL
NOT TO SCALE
NOTES:
1. VERIFY GENERATOR SIZES WITH OWNER. IF GENERATOR SIZES ARE DIFFERENT THAN WHAT
IS SHOWN, ADJUST ALL MEASUREMENTS SO THAT THE CLEARANCES ARE THE SAME AND THE
PAD IS PLACED IN GENERALLY THE SAME AREA.
E4.2
GENERATOR
AND ENCLOSURE
12"4"
18"
9"
GENERATOR
AND ENCLOSURE
BY OWNER
P A N E L B O A R D S C H E D U L E PANEL 'EM'
DIRECTORY LOAD (VOLT*AMPS) CKT
NO
BRKR
AMPS
BRKR
AMPS
CKT
NO
LOAD (VOLT*AMPS) DIRECTORY
A B C A B C
EXISTING PANEL 'LIG2' 13000 1 150/3 60/3 2 2220 PANEL 'L26'
| 13000 3 | | 4 2220 | | 13000 5 | | 6 2220 |
7 100/3 8 4733 EXISTING PANEL 'RPMC'
9 | 10 4733 | 11 | 12 4733 | 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
SUB-TOTAL 13000 13000 13000 6953 6953 6953 SUB-TOTAL
VOLTAGE : 120/208, 3PH, 4W PANEL TYPE: AQ TOTAL VA - A 19953 LOCATION
MAIN BREAKER : MLO MAIN BUS: 225A TOTAL VA - B 19953 ELEC. ROOM
MOUNTING: SURFACE A.I.C. RATING: 10K TOTAL VA - C 19953 TOTAL CONNECTED LOAD
NOTES: ENCLOSURE: NEMA 1 TOTAL VA 59859 166.28 A
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
ELECTRICAL LEGEND
F1
RECESSED LIGHT FIXTURE. SUBSCRIPT 'F1' REPRESENTS FIXTURE TYPE (SEE LIGHTING FIXTURE
SCHEDULE).
WALL MOUNTED LIGHT FIXTURE. SUBSCRIPT 'WA' REPRESENTS FIXTURE TYPE (SEE LIGHTING
FIXTURE SCHEDULE).
EXIT LIGHT SURFACE MOUNTED ON CEILING. IF NO ARROWS ARE SHOWN, THEN ALIGN FACE INTO
CORRIDOR OR OPEN ROOM WITH NO ARROWS.
DUAL TECHNOLOGY OCCUPANCY SENSOR (SENSORSWITCH #CM PDT 9), CEILING MOUNTED, FOR
STEP-DIMMING OF STAIRWELL LIGHT FIXTURES.
POWER PACK (SENSORSWITCH #PP20).
TRANSFORMER.
LIGHTING OR POWER BRANCH CIRCUIT PANELBOARD.
BRANCH CIRCUIT, CONCEALED ABOVE CEILING OR IN WALL, 1/2"c. UNLESS NOTED, WITH GREEN
GROUNDING ELECTRODE CONDUCTOR IN ADDITION TO CIRCUIT SHOWN, MINIMUM #12 AWG
COPPER.
BRANCH CIRCUIT WIRING (1 HOT, 1 NEUTRAL, 1 SWITCH LEG).
LOW VOLTAGE WIRING (PER MAUFACTURER'S RECOMMENDATIONS).
DUPLEX RECEPTACLE. SUBSCRIPT 'EX' DENOTES EXISTING TO REMAIN.
FIRE ALARM SYSTEM PULL STATION. SUBSCRIPT 'EX' DENOTES EXISTING TO REMAIN.
FIRE ALARM SYSTEM COMBINATION SMOKE/HEAT DETECTOR. SUBSCRIPT 'RL' DENOTES RELOCTAED
EXISTING DEVICE.
FIRE ALARM SYSTEM COMBINATION HORN/STROBE. SUBSCRIPT 'EX' DENOTES EXISTING TO REMAIN.
FIRE ALARM SYSTEM STROBE. SUBSCRIPT 'EX' DENOTES EXISTING TO REMAIN.
SYMBOL MANUFACTURE & CATALOG # REMARKSLAMP WATTS MOUNTING VOLTS
LIGHTING FIXTURE SCHEDULE
F1 COLUMBIA #LJT24-40MLG-FSA12125-ESD-U-ELL14
EQUAL BY: LITHONIA
COOPER
LED
4000K
52 RECESSED 120 RECESSED 2'X4' LUMINAIRE WITH: STEEL HOUSING (PAINTED WHITE); 0.125" ACRYLIC PRISMATIC
LENS; STEP-LEVEL DIMMER AND 90 MINUTE EMERGENCY BALLAST (SEE NOTE 6).
FIXTURE SCHEDULE NOTES:
1. ALL FIXTURES WITH EMERGENCY BATTERY PACKS SHALL BE FACTORY INSTALLED.
2. ALL LUMINAIRES AND INSTALLATION SHALL BE IN ACCORDANCE WITH NEC, NFPA, AND LOCAL CODES. ALL LUMINAIRES SHALL BE UL LISTED AND INSTALLED IN ACCORDANCE WITH THE UL LISTING.
3. ALL LUMINAIRE DEVICES, COMPONENTS, FITTINGS, SUPPORTS, ETC. SHALL BE COORDINATED TO PROVIDE A COMPLETE UL LISTED INSTALLATION.
4. ALL LUMINAIRE BALLASTS, DRIVERS, LAMPS, ETC. SHALL BE COMPATIBLE WITH THE LIGHTING CONTROL SYSTEM OR DIMMING CONTROLS SYSTEM PROVIDED.
5. SECURE EACH LAY-IN LUMINAIRE AT TWO LOCATIONS TO THE CEILING GRID. PROVIDE BOLTS, SCREWS, RIVETS OR APPROVED CLIPS FOR USE WITH THE TYPE PF CEILING GRID AND LUMINAIRE INSTALLED.
6. ALL EXIT SIGNS AND LUMINAIRES DESIGNATED AS EMERGENCY SHALL BE PROVIDED WITH A MINIMUM OF 1100 LUMEN EMERGENCY BATTERY BALLAST CAPABLE OF 90 MINUTES OF OPERATION.
WA HUBBELL #LMC-30LU-4K-3-035-1-B0C277/PC(120)
EQUAL BY: LITHONIA
METALUX
LED
4000K
43 SURFACE 120 ARCHITECTURAL WALL PACK: DIE-CAST ALUMINUM HOUSING (BRONZE); CLEAR GLASS LENS;
PHOTOCELL; AND 90 MINUTE EMERGENCY BALLAST, ZERO DEGREES.
E4.3
LAY-IN FIXTURE SUPPORT DETAIL
NOT TO SCALE
NOTES:
1. INDEPENDENT SUPPORT WIRES MUST BE MARKED (PAINTED) SO THAT THEY CAN BE
DISTINGUISHABLE AS NON CEILING SUPPORT WIRES PER N.E.C.
2. INDEPENDENT SUPPORT WIRES SHALL NOT HAVE AN ANGLE OF MORE THAN 45° FROM THE
CEILING GRID.
STRAP CONDUIT WITHIN 3' OF BOX
AND A MAXIMUM OF 10' THERE-AFTER
AS PER N.E.C.
JUNCTION BOX.
LIGHTING FIXTURE SUPPORT WIRE ATTACHED
TO STRUCTURAL MEMBERS SO THAT FIXTURE
IS SUPPORTED INDEPENDENT OF CEILING.
WIRE TO BE A MIN. OF #14 GAGE
PRESTRAIGHTENED GALV. ATTACHED AT
DIAGONAL CORNERS. (SEE NOTE 1.)
CEILING SUPPORT WIRE (TYP).
FLEXIBLE CONNECTION TO FIXTURE.
ATTACH TO STRUCTURE TO PREVENT
FLEX FROM RESTING ON CEILING.
CONDUIT.
LAY-IN LIGHT FIXTURE.
CEILING GRID.
ELECTRICAL CONTRACTOR SHALL
ATTACH FLEX CONDUIT WITH
APPROVED STRAP OR HANGER.
OC
GENERAL ELECTRICAL NOTES:
1. EXISTING SERVICES ARE 120/208 VOLT, 3 PHASE, 4 WIRE, WYE.
2. INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND
MANUFACTURER'S RECOMMENDATIONS.
3. ALL CONDUIT SIZES SHALL BE A MINIMUM OF 1/2" UNLESS OTHERWISE NOTED ON THE DRAWINGS.
4. CHECK ALL LIGHTING FIXTURES FOR EXACT TYPE MOUNTING AND SPACE REQUIRED BEFORE
ROUGHING IN. SUPPORT OF ALL LIGHT FIXTURES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL
CONTRACTOR. FIXTURES SHALL BE SUPPORTED INDEPENDENT OF CEILING FROM STRUCTURAL
MEMBERS OF THE BUILDING.
5. ALL CONDUIT SHALL BE CONCEALED UNLESS SPECIFICALLY NOTED/SHOWN EXPOSED.
6. A GREEN EQUIPMENT GROUNDING CONDUCTOR (SIZED PER N.E.C.) SHALL BE INSTALLED IN EACH AND
EVERY CONDUIT. INCLUDING BUT NOT LIMITED TO; BRANCH CIRCUITS, SWITCH LEGS, FEEDERS. ETC.
7. WHERE EXPOSED CONDUITS ARE NECESSARY, ELECTRICAL CONTRACTOR SHOULD MAKE HIS/HER
BEST EFFORT TO HAVE CONDUITS NEATLY (PARALLEL, PERPENDICULAR, STRAIGHT, ETC...) RUN
AGAINST WALLS.
8. PROVIDE MEANS BY DEFINITION TO FURNISH AND INSTALL.
9. FIRE ALARM SYSTEM SHALL BE RE-TESTED AND RE-CERTIFIED IN AREAS WHERE WORK WAS
PERFORMED/COMPLETED.
10. WIRING SYSTEM SHALL CONSIST OF COPPER WIRING INSTALLED IN CONDUIT, MINIMUM WIRE SIZE
SHALL BE #12 AWG.
11. ALL CONDUCTORS SHALL BE TYPE THHN.
12. CONDUIT ABOVE CEILINGS, IN WALLS, ETC., SHALL BE EMT WHERE NOT EXPOSED TO MOISTURE OR
DAMAGE. CONDUIT SUBJECT TO DAMAGE OUTSIDE BUILDING SHALL BE GALVANIZED RIGID CONDUIT.
CONDUIT SHALL BE SIZED IN ACCORDANCE WITH TABLE 1, CHAPTER 9 OF N.EC.
13. OUTLET BOXES SHALL BE GALVANIZED OR SHERADIZED SHEET-STEEL BOXES, AT LEAST 1-1/2" DEEP
AND SIZED AS PER N.E.C.
14. OUTLET BOXES AND ENCLOSURES WITH CONCENTRIC RING KNOCKOUTS SHALL BE PROVIDED WITH
BONDING JUMPERS FROM BUSHING TO ENCLOSURE.
15. ALL CONDUCTORS SHALL BE 99% COPPER (NO ALUMINUM CONDUCTORS BE ACCEPTED).
16. ALL ELECTRICAL EQUIPMENT IS TO BE FURNISHED BY ELECTRICAL CONTRACTOR.
17. THE ELECTRICAL CONTRACTOR SHALL CAREFULLY COORDINATE HIS WORK WITH OTHER
CONTRACTORS, THROUGH THE GENERAL CONTRACTOR, FOR SPACE REQUIREMENTS, FOR
EQUIPMENT AND LIGHTING FIXTURES AND LOCATIONS OF ELECTRICAL CONNECTIONS.
18. CONTRACTOR SHALL PROVIDE ALL MATERIAL NECESSARY TO FINALIZE A NEAT, COMPLETE AND
PROPERLY WORKING ELECTRICAL SYSTEM WHICH CONFORMS TO ALL LOCAL CODES AND THE
NATIONAL ELECTRICAL CODE AS PER PLANS, AND SPECS.
19. ANY BREAKERS ADDED TO EXISTING PANELS SHALL HAVE THE SAME AIC RATING AS EXISTING.
L
F
F
T
EX
EX
RL
EX
EX
X
X DUAL-LITE #LX-U-R-W-E-I
EQUAL BY: LITHONIA
COOPER
LED
W/UNIT
5 SURFACE 120 EXIT SIGN WITH: WHITE, THERMOPLASTIC HOUSING; RED LETTERING; INTEGRAL NICKEL CADMIUM
BATTERY AND CHARGER AND SELF-TESTING/SELF-DIAGNOSTIC ELECTRONICS (SEE NOTE 6).
PP
WA
LV
E4.3
STEP-DIMMING WIRING DIAGRAM
NOT TO SCALE
NOTES:
1. CIRCUIT 'SLA' IS ALWAYS ON.
2. CIRCUIT 'SLB' IS ON ONLY WHEN THE OCCUPANCY SENSOR DETECTS A PERSON IN THE
STAIRWELL.
G
N
H
POWER PACK MOUNTED
TO JUNCTION BOX.
LED LIGHT FIXTURE WITH
STEP-DIMMING
MODULE/DRIVER.
N
SLB (50% ILLUMINATION)
EXISTING
120V CIRCUIT
(INCOMING)
EXISTING JUNCTION BOX.
G
SLA (50% ILLUMINATION)
LVOC
B
903 SOUTH PERRY STREET
MONTGOMERY, AL 36104
T. (334) 269-0329 www.bordenandmorris.com
BORDEN
MORRIS
| E0.1 |
| E1.1 |
| E2.1 |
| E2.2 |
| E3.1 |
| E4.1 |
| E4.2 |
| E4.3 |
File details come from the government source that posted it. Updated .